Search NASA⌕ Search

SEARCH · Search NASA

Results for “saturation temperature”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

Soluble Organic Matter Molecular Atlas of Ryugu Reveals Cold Hydrothermalism on C-Type Asteroid Parent Body

The sample from the near-Earth carbonaceous asteroid (162173) Ryugu is analyzed in the context of carbonaceous meteorites soluble organic matter. The analysis of soluble molecules of samples collected by the Hayabusa2 spacecraft shines light on an extremely high molecular diversity on the C-type asteroid. Sequential solvent extracts of increasing polarity of Ryugu samples are analyzed using mass spectrometry with complementary ionization methods and structural information confirmed by nuclear magnetic resonance spectroscopy. Here we show a continuum in the molecular size and polarity, and no organomagnesium molecules are detected, reflecting a low temperature and water-rich environment on the parent body approving earlier mineralogical and chemical data. High abundance of sulfidic and nitrogen rich compounds as well as high abundance of ammonium ions confirm the water processing. Polycyclic aromatic hydrocarbons are also detected in a structural continuum of carbon saturations and oxidations, implying multiple origins of the observed organic complexity, thus involving generic processes such as earlier carbonization and serpentinization with successive low temperature aqueous alteration.

Asteroids, comets and Kuiper belt↗

Deep ROSAT HRI observations of the Orion nebula region

We present results from three deep ROSAT high-resolution imager observations of the Orion Nebula star-forming region. The X-ray images contain over 1500 cataloged stars in a roughly 0.8 sq deg region centered on the Trapezium. In all, 389 distinct X-ray sources have been detected, at least two-thirds of which are associated with a single proper-motion cluster member. X-ray emission is detected from stars of all spectral types, from massive O- and B-type components of the Trapezium to the coolest, low-mass pre-main-sequence (PMS) stars. In this paper we focus primarily on X-ray emission from the late-type PMS stars. Of the approximately 100 late-type cluster members with measured spectral types, approximately three-fourths have been detected; we have derived X-ray luminosity upper limits for the remaining stars. We found coronal X-ray emission turns on around spectral type F6, with the upper envelope of activity increasing with deceasing effective temperature. When plotted in an X-ray luminosity versus bolometric luminosity diagram, late-type PMS stars lie below a 'saturation' line corresponding to L(sub x)/L(sub bol) approximately 10(exp -3). For approximately solar-mass PMS stars, we find a median X-ray luminosity approximately 1 x 10(exp 30) ergs/s. The late G, K, and M stars exhibit nearly a two order of magnitude spread in X-ray luminosity and in L(sub x)/L(sub bol) at a given effective temperature. Plots of X-ray activity versus v sin i rotational velocity and rotational period appear to show no clear dependence of activity on rotation. However, because only a small fraction of late-type PMS stars in the Orion Nebula have measured v sin i or P(sub rot) and because of uncertainties in L(sub x) and L(sub x)/L(sub bol), we believe the data are not conclusive on this point. Light curves of the detected X-ray sources have revealed at least 10 strong X-ray flares with characteristic rise times greater than or approximately equal to 1 hr and decay times ranging from approximately 2 to 12 hr. All the flares have X-ray energies in excess of 3 x 10(exp 35) ergs. Many of the X-ray sources associated with late-type cluster members have been observed in more than one ROSAT HRI exposure, allowing us to look for variability on the approximately 1 yr timescale between HRI observations. A statistical analysis of the resulting count rate ratios suggests that at least one-fourth of the late-type cluster stars are significantly variable on this timescale.

Gagne, Marc↗

Room temperature persisting surface charge carriers driven by intense terahertz electric fields in a topological insulator Bi 2 Se 3

Topologically protected surface current is highly promising for next-generation low-dissipation and disorder-tolerant quantum electronics and computing. Yet, electric transport from the co-existing bulk state dominates the responses of the Dirac surface state, especially at elevated temperatures relevant to technological applications. Here, we present an approach that convincingly showcases the generation, disentanglement, and precise control of enduring surface charge carriers on a topological insulator, Bi 2 Se 3 , with high bulk conductivity, all achieved at room temperature. By using pump–probe modulation spectroscopy under ultrabroadband driving tunable from 4 meV to 1.55 eV, we show the terahertz (THz) field-induced surface carriers by discovering their initial temporal responses dominant over high density trivial bulk carriers. Strikingly, the response of the induced surface carrier responses persists for more than ~5 ps and is enhanced by reducing pump photon energy. The dynamics and lifetime of the distinct surface response manifest themselves as the enhanced THz pump-induced THz transmission, which directly correlates with the transient negative THz conductivity. Increasing the THz driving field reduces the induced surface carrier lifetime and identifies, particularly, an optimal pump field of E s ~ 224 kV cm -1 for generating the dominant surface response relative to the bulk. This surface carrier dominant regime is suppressed by a joint effect of enhanced surface-bulk scattering and a more rapid saturation of surface excitation compared to the bulk that sets in above E s . The controllability of room temperature topologically surface carriers through pump photon energy offer compelling possibilities for extending this approach to other topological complex materials.

36 MATERIALS SCIENCE↗

Alaska North Slope 2018 Hydrate-01 Stratigraphic Test Well: Technical Results

The Hydrate-01 Stratigraphic Test Well was drilled in December 2018 to confirm that a seismically-identified location within the western Prudhoe Bay Unit might be suitable for extended-duration scientific production testing. The well featured the acquisition of a full suite of logging-while-drilling data, collection of side-wall pressure cores, and installation of distributed temperature and distributed acoustic sensor (DTS, DAS) fiber-optic cables. Evaluation of the logging-while-drilling data confirms gas hydrate is present at high saturation in two target sands of high reservoir quality. Acquired logs and samples enable critical petrophysical information to be compiled for input into production models. The well tested two primary targets: the deeper Unit B is highly favorable due to optimal reservoir temperature and minimal observed risk for direct communication with permeable, hydrate-free water-bearing zones. The shallower Unit D provides a secondary target and opportunity to

Boswell, Ray↗

Magnetic properties of γ-Fe 2 O 3 nanoparticles in a porous SiO 2 shell for drug delivery

A method is presented for synthesizing core–shell nanoparticles with a magnetic core and a porous shell suitable for drug delivery and other medical applications. The core contains multiple γ -Fe 2 O 3 nanoparticles (~15 nm) enclosed in a SiO 2 (~100–200 nm) matrix using either methyl (denoted TMOS- γ -Fe 2 O 3 ) or ethyl (TEOS- γ -Fe 2 O 3 ) template groups. Low-temperature Mössbauer spectroscopy showed that the magnetic nanoparticles have the maghemite structure, γ -Fe 2 O 3 , with all the vacancies in the octahedral sites. Saturation magnetization measurements revealed that the density of γ -Fe 2 O 3 was greater in the TMOS- γ -Fe 2 O 3 nanoparticles than TEOS- γ -Fe 2 O 3 nanoparticles, presumably because of the smaller methyl group. Magnetization measurements showed that the blocking temperature is around room temperature for the TMOS- γ -Fe 2 O 3 and around 250 K for the TEOS- γ -Fe 2 O 3 . Three dimensional topography analysis shows clearly that the magnetic nanoparticles are not only at the surface but have penetrated deep in the silica to form the core–shell structure.

Physics↗

Experimental Heat Transfer Results and Flow Visualization of Vertical Upflow Boiling in Earth Gravity with Subcooled Inlet Conditions – In Preparation for Experiments Onboard the International Space Station

Since 2012, researchers at the Purdue University Boiling and Two-Phase Flow Laboratory (PU-BTPFL) and NASA Glenn Research Center have been collaborating on a long-term effort to study flow boiling and condensation in microgravity. The ultimate goal has been to develop the Flow Boiling and Condensation Experiment (FBCE) for the International Space Station (ISS). Based on the findings from prior flow boiling experiments both at different orientations in Earth gravity and onboard parabolic flights simulating short durations of microgravity, a final refined experiment design, construction, and operating procedure have been arrived at for long-duration microgravity flow boiling experiments onboard the ISS. This study investigates flow boiling of n-Perfluorohexane with subcooled inlet in a rectangular channel of dimensions 114.6 mm heated length, 2.5 mm width, and 5 mm height. These pre-launch experiments (Mission Sequence Testing) were conducted in vertical upflow orientation in Earth gravity using the same experimental rig that was launched to the ISS in August 2021. The various operating parameters varied are heating configuration (single- and double-sided), mass velocity (180 – 3200 kg/m2s), inlet subcooling (+0 – 32°C, encompassing both highly subcooled and near-saturated inlet conditions), and inlet pressure (119 – 191 kPa). High-speed video flow visualization images are presented to explain the two-phase interfacial physics within the channel’s heated section. Heat transfer results in terms of flow boiling curves, streamwise profiles of wall temperature and heat transfer coefficient, and averaged heat transfer coefficients are analyzed and parametric effects elucidated. Severe temporal thermodynamic equilibrium is observed for near-saturated inlet at very low velocities. Nucleate boiling degradation starts at larger heat fluxes for single-sided heating than double sided at low mass velocities with highly subcooled inlet, and conversely at high mass velocities with near-saturated inlet. Nucleate boiling degradation can be delayed to higher heat fluxes by highly subcooling the inlet and increasing mass velocity. The entire local heat transfer coefficient profiles are degraded at higher heat fluxes for near-saturated inlet, but only the downstream part for highly subcooled inlet. This study also confirmed reliability of the upcoming ISS experimental data for subcooled inlet conditions and the collected Earth-gravity data will be used for comparison against the ISS data.

flow boiling↗

Liquid Oxygen Thermodynamic Vent System Testing with Helium Pressurization

This report presents the results of several thermodynamic vent system (TVS) tests with liquid oxygen plus a test with liquid nitrogen. In all tests, the liquid was heated above its normal boiling point to 111 K for oxygen and 100 K for nitrogen. The elevated temperature was representative of tank conditions for a candidate lunar lander ascent stage. An initial test series was conducted with saturated oxygen liquid and vapor at 0.6 MPa. The initial series was followed by tests where the test tank was pressurized with gaseous helium to 1.4 to 1.6 MPa. For these tests, the helium mole fraction in the ullage was quite high, about 0.57 to 0.62. TVS behavior is different when helium is present than when helium is absent. The tank pressure becomes the sum of the vapor pressure and the partial pressure of helium. Therefore, tank pressure depends not only on temperature, as is the case for a pure liquid-vapor system, but also on helium density (i.e., the mass of helium divided by the ullage volume). Thus, properly controlling TVS operation is more challenging with helium pressurization than without helium pressurization. When helium was present, the liquid temperature would rise with each successive TVS cycle if tank pressure was kept within a constant control band. Alternatively, if the liquid temperature was maintained within a constant TVS control band, the tank pressure would drop with each TVS cycle. The final test series, which was conducted with liquid nitrogen pressurized with helium, demonstrated simultaneous pressure and temperature control during TVS operation. The simultaneous control was achieved by systematic injection of additional helium during each TVS cycle. Adding helium maintained the helium partial pressure as the liquid volume decreased because of TVS operation. The TVS demonstrations with liquid oxygen pressurized with helium were conducted with three different fluid-mixer configurations-a submerged axial jet mixer, a pair of spray hoops in the tank ullage, and combined use of the axial jet and spray hoops. A submerged liquid pump and compact heat exchanger located inside the test tank were used with all the mixer configurations. The initial series without helium and the final series with liquid nitrogen both used the axial jet mixer. The axial jet configuration successfully demonstrated the ability to control tank pressure; but in the normal-gravity environment, the temperature in the upper tank region (ullage and unwetted wall) was not controlled. The spray hoops and axial jet combination also successfully demonstrated pressure control as well as temperature control of the entire tank and contents. The spray-hoops-only configuration was not expected to be a reliable means of tank mixing because there was no direct means to produce liquid circulation. However, surprisingly good results also were obtained with the sprayhoops- only configuration (i.e., performance metrics such as cycle-averaged vent flowrate were similar to those obtained with the other configurations). A simple thermodynamic model was developed that correctly predicted the TVS behavior (temperature rise or pressure drop per TVS cycle) when helium was present in the ullage. The model predictions were correlated over a range of input parameters. The correlations show that temperature rise or pressure drop per cycle was proportional to both helium mole fraction and tank heat input. The response also depended on the tank fill fraction: the temperature rise or pressure drop (per TVS cycle) increased as the ullage volume decreased.

Thermodynamic vent system↗

Temperature dependence of the accommodation coefficient of liquid-helium film.

We have determined the accommodation coefficient, gamma, of a helium film from 1.15 to 4 K by measuring the time constant of a rotating superconducting Nb sphere levitated in vapor and covered with a saturated helium film. The conventional assumption of the phenomenological theory of superfluidity, that the order parameter psi vanishes at the free surface of helium II, implies that gamma, is unity and independent of temperature. We find that gamma, is nearly unity above the lambda point, suffers an abrupt drop close to T-lambda, and gradually levels off to the value of about 0.8 at lower temperatures.

Wang, T. G.↗

Ares I Reaction Control System Propellant Feedline Decontamination Modeling

The objective of the work presented here is to quantify the effects of purge gas temperature, pressure, and mass flow rate on Hydrazine (Hz) decontamination rates of the Ares I Roll Control System and Reaction Control System. A survey of experts in this field revealed the absence of any decontamination rate prediction models. Three basic decontamination methods were identified for analysis and modeling. These include low pressure eduction, high flow rate purge, and pulse purge. For each method, an approach to predict the Hz mass transfer rate, as a function of system pressure, temperature, and purge gas mass flow rate, is developed based on the applicable physics. The models show that low pressure eduction is two orders of magnitude more effective than the high velocity purge, which in turn is two orders of magnitude more effective than the pure diffusion component of pulse purging of deadheads. Eduction subjects the system to low pressure conditions that promote the extraction of Hz vapors. At 120 F, Hz is saturated at approximately 1 psia. At lower pressures and 120 F, Hz will boil, which is an extremely efficient means to remove liquid Hz. The Hz boiling rate is predicted by equating the rate at which energy is added to the saturated liquid Hz through heaters at the tube outer wall with the energy removed from the liquid through evaporation. Boil-off fluxes were predicted by iterating through the range of local pressures with limits set by the minimum allowed pressure of 0.2 psia and maximum allowed wall temperature of 120 F established by the heaters, which gives a saturation pressure of approximately 1.0 psia. Figure 1 shows the resulting boil-off fluxes as a function of local eduction pressure. As depicted in figure 1, the flux is a strong inverse function of eduction pressure, and that minimizing the eduction pressure maximizes the boil-off flux. Also, higher outer wall temperatures lead to higher boil-off fluxes and allow for boil-off over a greater range of eduction pressures.

Pasch, James J.↗

Time dependent model for non-inductive ECH X-I current ramp-up for SHPD tokamak facility

Non-inductive (NI) plasma current start-up and ramp-up is an important research topic for spherical tokamak (ST) based reactors and fusion pilot plant (FPP). For a compact FPP, the OH flux availability is highly restricted due to its compact geometry. Efficient fundamental extraordinary mode (X-I) electron cyclotron heating (ECH) current start-up and ramp-up regime was identified for a reactor-like high toroidal magnetic field range which has more than a hundred times higher current drive efficiency compared to more conventional ECH methods for the relevant start-up temperature range. High current drive efficiency is possible due to the strong X-I fundamental ECH interaction only with unidirectional passing electrons constrained by the wave accessibility conditions. Here, we extend the X-I electron cyclotron current drive (ECCD) investigation to a time dependent model to simulate the non-inductive current ramp-up to 10 MA for the Sustained High-Power Density (SHPD) facility. As the X-I ECCD driven current I EC rises, due to the back EMF driven negative current, the net plasma current Ip rises more slowly with the current resistive time scale. For tokamak confinement time (both L-mode and H-Mode) which tends to rise with I p , a positive feedback results and even with constant applied ECH power, T e0 , I EC , and I p can continue to rise to very high values. However, in a realistic situation, the T e0 rise should saturate due to a number of factors such as enhanced core radiation and increased power loss at high temperature. To simulate this effect, we adopt a maximum T e0 model which would limit the temperature rise to certain T e0 . With this model, we investigated the current ramp-up for various ECH power levels and the maximum T e0 of 15, 20, and 25 keV. We find that while the power required is reduced with increasing T e0 limit due to increased current drive efficiency, the time to reach 10 MA tends to go up due to the reduced plasma resistivity for the higher T e0 limit. We also find for a given Te0 limit, the time to reach 10 MA tends to be reduced by increasing the applied ECH power by over driving the current ramp-up where I EC is driven at significantly higher level than 10 MA. While the current ramp-up time may not be an issue for the steady-state reactor systems, if it is desirable to minimize the current ramp-up time, it is prudent to have a sufficient ECH power for current over-drive and have some T e0 limiting tools such as impurity seeding for enhanced radiation. In conclusion, a well-controlled NI ECH start-up also has a potential of improving the tokamak start-up reliability and avoid run-away electrons while the NI off-axis current drive could enhance MHD stability and plasma performance improvements.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Collisionless conduction in a high-beta plasma: a collision operator for whistler turbulence

The regulation of electron heat transport in high-β, weakly collisional, magnetized plasma is investigated. A temperature gradient oriented along a mean magnetic field can induce a kinetic heat-flux-driven whistler instability (HWI), which back-reacts on the transport by scattering electrons and impeding their flow. Previous analytical and numerical studies have shown that the heat flux for the saturated HWI scales as β$^{-1}_{e}$. These numerical studies, however, had limited scale separation and consequently large fluctuation amplitudes, which calls into question their relevance at astrophysical scales. To this end, we perform a series of particle-in-cell simulations of the HWI across a range of β$_e$ and temperature-gradient length scales under two different physical set-ups. The saturated heat flux in all of our simulations follows the expected β$^{-1}_{e}$ scaling, supporting the robustness of the result. We also use our simulation results to develop and implement several methods to construct an effective collision operator for whistler turbulence. The results point to an issue with the standard quasi-linear explanation of HWI saturation, which is analogous to the well-known 90° scattering problem in the cosmic-ray community. Despite this limitation, the methods developed here can serve as a blueprint for future work seeking to characterize the effective collisionality caused by kinetic instabilities.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The structure of the atmosphere of Uranus

Models of the interior of Uranus suggest that the abundances of such substances as CH4 are greatly enhanced with respect to solar abundances of heavy elements. Such enhancement leads to a new type of model atmosphere for Uranus, which agrees with observation if the internal energy flux is small (no more than 10%) compared with the absorbed solar energy. An important feature of the models is the presence of a cloud of CH4 droplets whose top is at a temperature of approximately 90 K and a pressure of about 4 atm. Above the cloud, the atmosphere is stable because of the rapid decrease in the thermal flux with depth. Being saturated, most of the observable gaseous CH4 is near the cloud; the CH4 abundance above the cloud, of the order of 5 km-am, is a very sensitive function of the cloud-top temperature.

Danielson, R. E.↗

Structure-property correlations and scaling in the magnetic and magnetocaloric properties of GdCrO 3 particles

The structure, magnetic, and magnetocaloric (MC) properties of orthorhombic nanocrystalline GdCrO 3 with six particle sizes: < d > = 87, 103, 145, 224, 318, and 352 nm are reported. The particle size was tailored by annealing under different temperatures and estimated by scanning electron microscopy. With increase in < d >, Goldschmidt tolerance factor t, orthorhombic strain s, and out-of-plane Cr–O 1 –Cr bond angle first decrease, reaching minimum values for < d > = 224 nm, and then increase for sample with < d > = 318 nm and 352 nm, thus showing a V-shaped variation. Temperature dependence of the magnetization (M) reveals an antiferromagnetic transition at ${T}_{\text{N}}^{\text{Cr}}\sim 168$ K for < d > ≥ 224 nm and ${T}_{\text{N}}^{\text{Cr}}\sim 167$ K for < d > < 224 nm and an essentially d-independent spin-reorientation at T SR = 9 K. M measured at 5 K and 7 T first increases with increase in < d >, reaching maximum value for sample with < d > = 224 nm, and then decreases for samples with < d > = 318 nm and 352 nm, showing an inverted-V variation with < d >. Similar < d >-dependence is observed for the magnetic entropy change (MEC) and relative cooling power (RCP) showing a close relationship between the structural and magnetic properties of GdCrO 3 nanoparticles investigated here. The 224 nm sample with the minimum values of t, s, and Cr–O 1 –Cr bond angle exhibits the maximum value of MEC (–ΔS) = 37.8 J kg –1 K –1 at 5 K under a field variation (ΔH) of 7 T and its large estimated RCP of 623.6 J Kg –1 is comparable with those of typical MC materials. Both (–ΔS) and RCP are shown to scale with the saturation magnetization MS, suggesting that MS is the crucial factor controlling their magnitudes. Assuming (–ΔS) ~ (ΔH) n , the temperature dependence of n for the six samples are determined, n varying between 1.3 at 5 K to n = 2.2 at 130 K in line with its expected magnitudes based on mean-field theory. Furthermore, these results on structure-property correlations and scaling in GdCrO 3 suggest that its MC properties are tunable for potential low-temperature magnetic refrigeration applications.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A Generalized Multi-Phase Framework for Modeling Cavitation in Cryogenic Fluids

A generalized multi-phase formulation for cavitation in fluids operating at temperatures elevated relative to their critical temperatures is presented. The thermal effects and the accompanying property variations due to phase change are modeled rigorously. Thermal equilibrium is assumed and fluid thermodynamic properties are specified along the saturation line using the NIST-12 databank. Fundamental changes in the physical characteristics of the cavity when thermal effects become pronounced are identified; the cavity becomes more porous, the interface less distinct, and has increased entrainment when temperature variations are present. Quantitative estimates of temperature and pressure depressions in both liquid nitrogen and liquid hydrogen were computed and compared with experimental data of Hord for hydrofoils. Excellent estimates of the leading edge temperature and pressure depression were obtained while the comparisons in the cavity closure region were reasonable. Liquid nitrogen cavities were consistently found to be in thermal equilibrium while liquid hydrogen cavities exhibited small, but distinct, non-equilibrium effects.

Dorney, Dan↗

Simultaneous x-ray and neutron 4D tomographic study of drying-driven hydro-mechanical behavior of cement-based materials at moderate temperatures

The drying of cement-based materials is intimately related to their durability, which has significant economic, social and environmental repercussions. The evolution of the saturation of the pore network and the associated drying shrinkage are in fact leading causes of cracking and of the ensuing penetration of aggressive chemicals. This process is highly heterogeneous, due to the thermo-hydric spatial gradients developing in the material from the exposed surfaces to its core and because of local effects, driven by the intrinsically heterogeneous micro-structure (e.g., by the distribution of pores and aggregates). It follows that macroscopic, sample-scale measurements cannot fully disclose the complexity of the underlying processes. In the last few decades, significant advances in full-field techniques have allowed an unprecedented insight into these local processes. For cement-based materials, x-ray and neutron tomography lend themselves as ideal, and highly complementary, tools for the study of their thermo-hydro-mechanical behavior. Notably, the high sensitivity to density variations of x-ray imaging gives access to the developments of fractures, in 4D (3D + time). On the other hand, neutron tomography allows the study of the evolution of the moisture field in 4D, thanks to its high hydrogen sensitivity. The combination of these two techniques provides a unique insight in thermo-hydro-mechanical couplings, e.g., the effect of cracks on the water content field. This contribution presents novel 5D datasets (3D tomographies along time, plus truly simultaneous x-ray and Neutron rapid acquisitions) in-operando of a cement paste and of a concrete sample heated at moderate temperatures (up to 140{sup ∘}C). The analysis of this 5D data-set (once aligned in time and across modalities) allows for example a quantification of the 4D moisture profiles which were found to predict an overall water loss at hydric equilibrium coherent with the corresponding analytical analysis. In the cement paste sample, the x-ray dataset captures the evolution of an extensive cracking network, opening and propagation toward the core of the sample. A novel analysis procedure is here proposed which allows the extraction of these fractures and the analysis of their interplay with local drying as captured through neutron imaging. This for example reveals the depth of penetration of drying in the vicinity of the fractures along time, which is essential for the assessment and calibration of hydro-mechanical coupled models.

36 MATERIALS SCIENCE↗

Experimental Constraints on Ureilite Petrogenesis

This experimental study explores the petrogenesis of ureilites by a partial melting/smelting process. Experiments have been performed over temperature (1150-1280 C), pressure (5-12.5 MPa), and low oxygen fugacity (graphite-CO gas) conditions appropriate for a hypothetical ureilite parent body approximately 200 km in size. Experimental and modeling results indicate that a partial melting/smelting model of ureilite petrogenesis can explain many of the unique characteristics displayed by this meteorite group. Compositional information preserved in the pigeonite-olivine ureilites was used to estimate the composition of melts in equilibrium with the ureilites. The results of 20 experiments saturated with olivine, pyroxene, metal, and liquid with appropriate ureilite compositions are used to calibrate the phase coefficients and pressure-temperature dependence of the smelting reaction. The calibrated coefficients are used to model the behavior of a hypothetical residue that is experiencing fractional smelting. The residue is initially olivine-rich and smelting progressively depletes the olivine content and enriches the pyroxene and metal contents of the residues. The modeled residue composition at 1260 C best reproduces the trend of ureilite bulk compositions. The model results also indicate that as a ureilite residue undergoes isothermal decompression smelting over a range of temperatures, Ca/Al values and Cr203 contents are enriched at lower temperatures (below about 1240 C) and tend to decrease at higher temperatures. Therefore, fractional smelting can account for the high Ca/A1 and Cr203 wt% values observed in ureilites. We propose that ureilites were generated from an olivine-rich, cpx-bearing residue. Smelting began when the residue was partially melted and contained liquid, olivine, and carbon. These residues experienced varying degrees of fractional smelting to produce the compositional variability observed within the pigeonite-bearing ureilites. Variations in mineral composition, modal proportions, and isotopic signatures are best described by heterogeneous accretion of the ureilite parent body followed by minimal and variable degrees of igneous processing.

Singletary, Steven↗

Spectral analysis of temperature and Brunt-Vaisala frequency fluctuations observed by radiosondes

Recent studies have revealed that vertical wave number spectra of wind velocity and temperture fluctuations in the troposphere and the lower stratosphere are fairly well explained by a saturated gravity wave spectrum. But N(2) (N:Brunt-Vaisala (BV) frequency) spectra seem to be better for testing the scaling of the vertical wave number spectra in layers with different stratifications, beause its energy density is proportional only to the background value of N(2), while that for temperature depends on both the BV frequency and the potential temperature. From temperature profiles observed in June to August 1987 over the MU Observatory, Japan, by using a radiosonde with 30 m height resolution, N(2) spectra are determined in the 2 to 8.5 km (troposphere) and 18.5 to 25 km (lower stratosphere) ranges. Although individual spectra show fairly large day-by-day variability, the slope of the median of 34 spectra agrees reasonably with the theoretical value of -1 in the wave number range of 6 x 10(-4) similar to 3 x 10(-3) (c/m). The ratio of the spectral energy between these two height regions is about equal to the ratio of N(2), consistent with the prediction of saturated gravity wave theory.

Tsuda, T.↗

In situ effective pumping speed measurements as a tool for non-evaporable getter activation and saturation monitoring

We have developed method of in situ effective pumping speed measurements based on injecting finite gas pulse into a vacuum volume and subsequent recording of pressure response using a Residual Gas Analyzer (RGA). The pressure burst caused by injected gas pulse falls exponentially in time and the exponential coefficient of such pressure decay is proportional to total effective pumping speed of all vacuum pumps acting on vacuum chamber volume. The effective pumping speed can be extracted from the dependence of injected gas species pressure vs time recorded by an RGA. Non-Evaporable Getters (NEGs) are widely used in multiple ultra and extremely high vacuum devices and applications during the last several decades. Areas of NEG applications were recently expanded into vacuum devices with relatively high-pressure levels (up to 10 -7 Torr) by the invention of high capacity ZAO NEG which can be operated at elevated temperatures. The intrinsic property of all NEG-based vacuum pumps is the reduction of their pumping speed, called “NEG saturation”, after an extended period of operation. Typical time interval for such process can span from about a month and up to a few years depending on NEG type, vacuum level of NEG pump operation, and residual gas content. After that, the NEG pump will require a re-activation cycle to restore its pumping speed close to the initial value. For many applications it is difficult to realize what is the current pumping speed of NEG pump is and when the pump should be re-activated. A method for in situ effective pumping speed measurements developed in this study can be used as a tool for NEG-based pump activation and saturation monitoring. Application of such an approach to monitor pumping status of NEG pumps was utilized and will be continually used at Extended EBIS which was recently developed and commissioned for Relativistic Heavy Ion Collider (RHIC) and future Electron Ion Collider (EIC). The results obtained during commissioning are presented and discussed.

43 PARTICLE ACCELERATORS↗