Search NASA⌕ Search

SEARCH · Search NASA

Results for “side load”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

Frequency Responsive Demand in U.S. Western Power System Model

Frequency control from the demand side presents a novel and viable way to complement control by traditional generators. This paper presents simulation tests of a previously developed load controller in a large interconnected system model. The controller was implemented as a user defined model in PowerWorld software. WECC system model was used. The simulation tests include comparison of situation with and without control, sensitivities to controller location, control gain parameters, and type of end-use loads. The performance is measured in terms of frequency and intertie power flow deviations after a large generator outage.

Power system dynamics, power system control↗

Characterization of textile-grade carbon fiber polypropylene composites

In this work, we consider low-cost carbon fiber produced with a textile-grade precursor. The objective of the study is to investigate textile-grade carbon-fiber-reinforced-polypropylene composites (TCF-PP) from compounded pellets for mechanical and thermal characterization. Four sets of pellets with 1%, 5%, 10%, and 15% reinforcement were manufactured using textile-grade carbon fiber (TCF) and polypropylene (PP) by twin-screw compounding. The addition of TCFs through gravimetric feeder directly in the extruder resulted in lower fiber content; however, side feeder has shown good potential. The pellets were further processed in extrusion compression molding to manufacture plaques. An increase in fiber loading has a negligible effect on fiber attrition as fiber length distribution variation between 1% and 15% reinforced pellets was very small. The addition of TCFs in PP showed a significant improvement in mechanical properties. The tensile strength and modulus of the composite were 26% and 161%, respectively, improved by the addition of 10 wt% TCF. Similar results were observed in the flexure test. However, the impact properties were reduced by 25.54% by the addition of 15% TCF.

36 MATERIALS SCIENCE↗

In-Situ Blade Strain Measurements of a Crossflow Turbine Operating in a Tidal Flow

This data was collected between October 25 and December 12 of 2022 at the University of New Hampshire (UNH) and Atlantic Marine Energy Center (AMEC) turbine deployment platform (TDP). The goal was to collect blade strain data from a crossflow turbine operating in a tidal flow. A table in ('Deployment Schedule.PNG') outlines the various dates when each instrument was operational, and more details can be found via literature listed in 'Related Publications'.txt. This dataset includes zipped folders for each instrument containing data in .csv files for the relevant duration specific to each instrument, along with separate README file for each measurement. Some instrument files are quite large and can pose a challenge for a visual spreadsheet editor to open. A processing software like MATLAB or Python is recommended. All data contained in this submission is unfiltered/unprocessed data unless otherwise noted in the README file. Blade strain was measured using 8 foil-based strain gauges along the span of a single turbine blade. Water currents were measured using Acoustic Doppler Current Profilers (ADCP's) and Acoustic Doppler Velocimeters (ADV's) both upstream and downstream of the turbine for inflow, wake and turbulence measurements. Electrical power output was measured using the Voltsys rectifier. Shaft speed was calculated based on the Voltsys measurements of the permanent magnet three phase generator AC generation frequency, coupled directly to the cross flow turbine under test (i.e., no gear box). Platform motions were captured using a Yost IMU (inertial measurement unit). Turbine thrust loading was measured using a reaction arm about the turbine deployment platform spanning beam, where two bi-directional load cells were connected to the system via a pinned connection. The TDP is a floating structure moored on the Portsmouth facing side of Memorial Bridge pier #2, which spans the Piscataqua River between Portsmouth, NH and Kittery, ME. The Piscataqua River connects the Great Bay Estuary to the Gulf of Maine and the river currents are dominated by tidal flow with water velocities exceeding 2.5 m/s during spring ebb tides at this site which were previously characterized by Chancey 2019. The turbine under test was a modified New Energy Corporation (Calgary, CA) model EVG-025 4-blade H-Darrius type vertical axis cross flow turbine that rotates in the clockwise direction with a rotor diameter of 3.2m and blade length of 1.7m. The hydro-foil profile was a NACA 0021 with a 10 inch chord length and a blade preset pitch angle of +4deg with a positive angle corresponding with the toe in direction. The standard EVG-025 has a rotor diameter of 3.4m and its rated power output is 25kW at 3 m/s. The rotor diameter was reduced to accommodate the size of the existing TDP moon-pool. A single blade of this turbine was further modified to accommodate 8 full-bridge strain gauges (Bharath et al 2023, Bichanich et al 2024). For power performance and other relevant details on the turbine and its characteristics, see O'Byrne 2022.

16 TIDAL AND WAVE POWER↗

Analysis of Joist Masonry Moisture Content Monitoring

There are many existing buildings with load-bearing mass masonry walls, whose energy performance could be improved with the retrofit of insulation. However, adding insulation to the interior side of walls of such masonry buildings in cold (and wet) climates may cause performance and durability problems. Some concerns, such as condensation and freeze-thaw have known solutions. But wood members embedded in the masonry structure will be colder (and potentially wetter) after an interior insulation retrofit. Moisture content & relative humidity were monitored at joist ends in historic mass brick masonry walls retrofitted with interior insulation in a cold climate (Zone 5A); data were collected from 2012-2015. Eleven joist ends were monitored in all four orientations. One limitation of these results is that the renovation is still ongoing, with limited wintertime construction heating and no permanent occupancy to date. Measurements show that many joists ends remain at high moisture contents, especially at north- and east-facing orientations, with constant 100% RH conditions at the worst cases. These high moisture levels are not conducive for wood durability, but no evidence for actual structural damage has been observed. Insulated vs. non-insulated joist pockets do not show large differences. South facing joists have safe (10-15%) moisture contents. Given the uncertainty pointed out by research, definitive guidance on the vulnerability of embedded wood members is difficult to formulate. In high-risk situations, or when a very conservative approach is warranted, the embedded wood member condition can be eliminated entirely, supporting the joist ends outside of the masonry pocket.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Policy-Driven Sustainable Saline Drainage Disposal and Forage Production in the Western San Joaquin Valley of California

Environmental policies to address water quality impairments in the San Joaquin River of California have focused on the reduction of salinity and selenium-contaminated subsurface agricultural drainage loads from westside sources. On 31 December 2019, all of the agricultural drainage from a 44,000 ha subarea on the western side of the San Joaquin River basin was curtailed. This policy requires the on-site disposal of all of the agricultural drainage water in perpetuity, except during flooding events, when emergency drainage to the River is sanctioned. The reuse of this saline agricultural drainage water to irrigate forage crops, such as ‘Jose’ tall wheatgrass and alfalfa, in a 2428 ha reuse facility provides an economic return on this pollutant disposal option. Irrigation with brackish water requires careful management to prevent salt accumulation in the crop root zone, which can impact forage yields. The objective of this study was to optimize the sustainability of this reuse facility by maximizing the evaporation potential while achieving cost recovery. This was achieved by assessing the spatial and temporal distribution of the root zone salinity in selected fields of ‘Jose’ tall wheatgrass and alfalfa in the drainage reuse facility, some of which have been irrigated with brackish subsurface drainage water for over fifteen years. Electromagnetic soil surveys using an EM-38 instrument were used to measure the spatial variability of the salinity in the soil profile. The tall wheatgrass fields were irrigated with higher salinity water (1.2–9.3 dS m -1 ) compared to the fields of alfalfa (0.5–6.5 dS m -1 ). Correspondingly, the soil salinity in the tall wheatgrass fields was higher (12.5 dS m -1 –19.3 dS m -1 ) compared to the alfalfa fields (8.97 dS mm -1 –14.4 dS mm -1 ) for the years 2016 and 2017. Better leaching of salts was observed in the fields with a subsurface drainage system installed (13–1 and 13–2). The depth-averaged root zone salinity data sets are being used for the calibration of the transient hydro-salinity computer model CSUID-ID (a one-dimensional version of the Colorado State University Irrigation Drainage Model). This user-friendly decision support tool currently provides a useful framework for the data collection needed to make credible, field-scale salinity budgets. In time, it will provide guidance for appropriate leaching requirements and potential blending decisions for sustainable forage production. This paper shows the tie between environmental drainage policy and the role of local governance in the development of sustainable irrigation practices, and how well-directed collaborative field research can guide future resource management.

54 ENVIRONMENTAL SCIENCES↗

A life comparison of tube and channel cooling passages for thrust chambers

The life analysis used to compare copper tubes and milled copper channels for rocket engine cooling passages is described. Copper tubes were chosen as a possible replacement for the existing milled copper channel configuration because (1) they offer increased surface area for additional enthalpy extraction; (2) they have ideal pressure vessel characteristics; and (3) the shape of the tube is believed to allow free expansion, thus accommodating the strain resulting from thermal expansion. The analysis was a two-dimensional elastic-plastic comparison, using a finite element method, to illustrate that, under the same thermal and pressure loading, the compliant shape of the tube increases the life of the chamber. The analysis indicates that for a hot-gas-side-wall temperature of 100 F the critical strain decreases from 1.25 percent in the channel to 0.94 percent in the tube. Since the life of rocket thrust chambers is most often limited by cyclic strain or strain range, this decrease corresponds to an expected tube life which is nearly twice the channel life.

Jankovsky, R. S.↗

Experimental Stress Analysis of Stiffened Cylinders with Cutouts : Shear Load

A cylindrical semimonocoque shell of circular cross section was mounted as a cantilever and loaded by a direct shear at the tip. The cylinder was tested with no cutout, with a rectangular cutout on the tension side, and with the cutout centered on the neutral axis on one side of the cylinder. The cutout was successively enlarged through six sizes varying from 30 degrees to 130 degrees in circumference and from 1 and 2 bays in length. Strain measurements were made with resistance-type wire strain gages near the cutout on the stringers, the skin, and the rings for each case, and the stresses obtained are presented in tables. (author)

Rosecrans, Richard↗

Hydro-isostatic deflection and tectonic tilting in the central Andes: Initial results of a GPS survey of Lake Minchin shorelines

Sufficiently large lake loads provide a means of probing rheological stratification of the crust and upper mantle. Lake Minchin was the largest of the late Pleistocene pluvial lakes in the central Andes. Prominent shorelines, which formed during temporary still-stands in the climatically driven lake level history, preserve records of lateral variations in subsequent net vertical motions. At its maximum extent the lake was 140 m deep and spanned 400 km N-S and 200 km E-R. The load of surficial water contained in Lake Minchin was sufficient to depress the crust and underlying mantle by 20-40 m, depending on the subjacent rheology. Any other differential vertical motions will also be recorded as departures from horizontality of the shorelines. We recently conducted a survey of shoreline elevations of Lake Minchin with the express intent of monitoring the hydro-isostatic deflection and tectonic tilting. Using real-time differential Global Positioning System (GPS), we measured topographic profiles across suites of shorelines at 15 widely separated locations throughout the basin. Horizontal and vertical accuracies attained are roughly 30 and 70 cm, respectively. Geomorphic evidence suggests that the highest shoreline was occupied only briefly (probably less than 200 years) and radiocarbon dates on gastropod shells found in association with the shore deposits constrain the age to roughly 17 kyr. The basin-side pattern of elevations of the highest shoreline is composed of two distinct signals: (27 +/- 1) m of hydro-isostatic deflection due to the lake load, and a planar tilt with east and north components of (6.8 +/- 0.4) 10(exp -5) and 9-5.3 +/- 0.3) 10(exp -5). This rate of tilting is too high to be plausibly attributed to steady tectonism, and presumably reflects some unresolved combination of tectonism plus the effects of oceanic and lacustrine loads on a laterally heterogeneous substrate. The history of lake level fluctuations is still inadequately known to allow detailed inferences of crust and mantle rheology. However, it is already clear that the effective elastic plate thickness is closer to 40 km than the 60-70 km crustal thickness in the central Andes and the effective viscosity is less than 5 10(exp 20) Pa s.

Bills, Bruce G.↗

Power Actuation and Switching Module Test Results

The X2000 Power System Electronics (PSE) is a Jet Propulsion Laboratory (JPL) task to develop a new generation of power system building blocks for use on future deep-space missions. The effort includes the development of electronic components and modules that can be used as building blocks in the design of generic spacecraft power systems. All X2000 avionics components and modules are designed for use in centralized or distributed spacecraft architectures. The Power Actuation and Switching Module (PASM) has been developed under the X2000 program. This component enables a modular and scalable design approach for power switching applications, which can result in a wide variety of power switching architectures using this simple building block. The PASM is designed to provide most of the necessary power switching functions of spacecraft for various Deep Space missions including future missions to Mars, comets, Jupiter and its moons. It is fabricated using an ASIC process that is tolerant of high radiation. The development included two application specific integrated circuits (ASICs) and support circuitry all packaged using High Density Interconnect (HDI) technology. It can be operated in series or parallel with other PASMs. It can be used as a high-side or low-side switch and it can drive thruster valves, pyrotechnic devices such as NASA standard initiators, bus shunt resistors, and regular spacecraft component loads. Each PASM contains two independent switches with internal current limiting and over-current trip-off functions to protect the power subsystem from load faults. During turnon and turnoff each switch can limit the rate of current change (di/dt) to a value determined by the user. Three-way majority-voted On/Off commandability and full switch status telemetry (both analog and digital) are built into the module. This paper is a follow up to the one presented at he IECEC 2004 conference that will include the lessons learned and test results from the development.

X2000↗

Power Actuation and Switching Module Development

The Deep Space Avionics (DSA) Project is developing a Power Actuation and Switching Module (PASM). This component enables a modular and scalable design approach for power switching applications, which can result in a wide variety of power switching architectures using this simple building block. The PASM is designed to provide most of the necessary power switching functions of spacecraft for various Deep Space missions including future missions to Mars, comets, Jupiter and its moons. It is fabricated using an A SIC process that is tolerant of high radiation. The development includes two application specific integrated circuits (ASICs) and support circuitry all packaged using High Density Interconnect (HDI) technology. It can be operated in series or parallel with other PASMs, It can be used as a high-side or low-side switch and it can drive thruster valves, pyrotechnic devices such as NASA standard initiators, bus shunt resistors, and regular spacecraft component loads. Each PASM contains two independent switches with internal current limiting and over-current trip-off functions to protect the power subsystem from load faults. During turnon and turnoff each switch can limit the rate of current change (di/dt) to a value determined by the user. Threeway majority-voted On/Off commandability and full switch status telemetry (both analog and digital) are built into the module. This paper describes the development process used to design, model, fabricate, and test these compact and versatile power switches. Preliminary test results from prototype HDI PASM hardware are also discussed.

Power Actuation and Switching Module (PASM)↗

DNS of Low-Pressure Turbine Cascade Flows with Elevated Inflow Turbulence Using a Discontinuous-Galerkin Spectral-Element Method

Recent progress towards developing a new computational capability for accurate and efficient high-fidelity direct numerical simulation (DNS) and large-eddy simulation (LES) of turbomachinery is described. This capability is based on an entropy- stable Discontinuous-Galerkin spectral-element approach that extends to arbitrarily high orders of spatial and temporal accuracy, and is implemented in a computationally efficient manner on a modern high performance computer architecture. An inflow turbulence generation procedure based on a linear forcing approach has been incorporated in this framework and DNS conducted to study the effect of inflow turbulence on the suction- side separation bubble in low-pressure turbine (LPT) cascades. The T106 series of airfoil cascades in both lightly (T106A) and highly loaded (T106C) configurations at exit isentropic Reynolds numbers of 60,000 and 80,000, respectively, are considered. The numerical simulations are performed using 8th-order accurate spatial and 4th-order accurate temporal discretization. The changes in separation bubble topology due to elevated inflow turbulence is captured by the present method and the physical mechanisms leading to the changes are explained. The present results are in good agreement with prior numerical simulations but some expected discrepancies with the experimental data for the T106C case are noted and discussed.

Garai, Anirban↗

TPSAS-NF1676L-32867-DND

During the summer of 2019, a Fokker F28 MK1000 aircraft was crash tested at the Landing and Impact Research Facility (LandIR) at NASA Langley Research Center (LaRC). The test, which was conducted in cooperation with the FAA Technical Center and the FAA Civil Aeromedical Institute (CAMI), had multiple objectives. The first objective was to obtain data for aircraft undergoing a combined vertical plus horizontal impact condition, and then compare results to aircraft sections under vertical loading only. The second was to evaluate Anthropomorphic Test Devices (ATDs, a.k.a. crash test dummies) of various sizes and positions for the determination of occupant injury. The third was to evaluate new and novel experimental ATDs including a larger Hybrid III, the Test Device for Human Occupant Restraint (THOR), and the Warrior Injury Assessment Manikin (WIAMan). Finally, the generated data was used to calibrate and validate computer simulation efforts. On-board data acquisition systems (DAS) captured loading on the airframe and the 24 on-board occupants while multiple high-speed cameras captured the motion. The port side of the airframe was painted with a stochastic monochromatic speckle pattern to allow for the collection of high-speed airframe deformation digital image correlation data. Airframe and occupant responses from each of the tests will be presented, and airframe and restraint performance will be discussed.

Justin Littell↗

Building America Case Study: Retrofit Measure for Embedded Wood Members in Insulated Mass Masonry Walls, Lawrence, Massachusetts

?There are many existing buildings with load-bearing mass masonry walls, whose energy performance could be improved with the retrofit of insulation. However, adding insulation to the interior side of walls of such masonry buildings in cold (and wet) climates may cause performance and durability problems. Some concerns, such as condensation and freeze-thaw have known solutions. But wood members embedded in the masonry structure will be colder (and potentially wetter) after an interior insulation retrofit. Moisture content and relative humidity were monitored at joist ends in historic mass brick masonry walls retrofitted with interior insulation in a cold climate (Zone 5A); data were collected from 2012-2015. Eleven joist ends were monitored in all four orientations. One limitation of these results is that the renovation is still ongoing, with limited wintertime construction heating and no permanent occupancy to date. Measurements show that many joists ends remain at high moisture contents, especially at north- and east-facing orientations, with constant 100 percent RH conditions at the worst cases. These high moisture levels are not conducive for wood durability, but no evidence for actual structural damage has been observed. Insulated vs. non-insulated joist pockets do not show large differences. South facing joists have safe (10-15 percent) moisture contents. Given the uncertainty pointed out by research, definitive guidance on the vulnerability of embedded wood members is difficult to formulate. In high-risk situations, or when a very conservative approach is warranted, the embedded wood member condition can be eliminated entirely, supporting the joist ends outside of the masonry pocket.

BSC↗

DC compensation for power transformer through neutral DC injection

A power transmission system can include a transformer and compensator circuit(s), each coupled between a node of the transformer and a ground connection. The compensator circuit(s) can each be configured to counteract a DC signal component of an AC signal at the transformer. The compensator circuit(s) can include a converter circuit having an AC side and a DC side and configured to convert a DC voltage on the DC side to an AC signal at the AC side. The compensator circuit(s) can include a DC link coupled to the DC side of the converter circuit. The compensator circuit(s) can include a controller configured to measure a DC signal component between the load and the ground; to determine, based at least in part on the DC signal component, a compensating signal configured to counteract the DC signal component; and to inject, by the converter circuit, the compensating signal to counteract the DC signal component.

Burkes, Klaehn W.↗

The Flow Visualization for the Separation of Air-water Bubbly Two-phase Flow Through a Vertical T-junction

T-junction is a typical structure in many industrial systems such as power plants, chemical process, and hydrocarbon production industries. The separation of two-phase flow passing through T-junction is a common flow phenomenon. There are lots of investigations regarding two-phase flow separation in branching tees and wyes tees. The characteristic of the two-phase flow between the two outlets are always non-uniform, and this kind of fluid status may contribute to the unpredictable damage of downstream facilities. For the nuclear power plants, severe accidents analysis is important especially for Light-Water Reactors (LWR) when Loss of Coolant Accident (LOCA) occurs. The small break of the pipe may cause the coolant become two-phase flow due to the pressure drop. Under certain conditions, the behavior of T-junction is similar to a gas-liquid separator, as a result of the gas enters the side arm and the liquid flows straight along the run arm. The partial separation of gas-liquid mixtures can reduce the load on the main separator, probably leading to smaller units. The study aims to establish complete visual observations for the benchmark of Computational Fluid Dynamics (CFD) model. As a consequence, a vertical T-junction (D = 26 mm) experimental loop was set up for the purpose of elaborating the complex two-phase fluid phenomena. In this experiment, variables were manipulated under highly controlled conditions and a photographic method was proposed to analyze the images of phase separation. Furthermore, the images obtained by camera have been discussed to receive valuable information about the two phase flow behavior around the T-junction.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Influence of river level on temperature and hydraulic gradients in chum and fall Chinook salmon spawning areas downstream of Bonneville Dam, Columbia River

Chum (Oncorhynchus keta) and fall Chinook (O. tshawytscha) salmon segregate spatially during spawning in the Ives Island side channel of the lower Columbia River downstream from Bonneville Dam. Previous research during one spawning season (2000) suggested that these species selected spawning habitats based on differences in hyporheic temperature and vertical hydraulic gradient (VHG) with the river. In this study, we confirmed the spatial segregation of spawning based on hyporheic characteristics over four years (2001–2004) and examined the effects of load-following operations (power generation to meet short-term electrical demand) at Bonneville Dam on hyporheic function and characteristics. We found that during the study period, hyporheic temperature and VHG in chum salmon spawning areas were highly variable during periods of load-following operation when river levels fluctuated. In contrast, hyporheic water temperature and VHG within chum spawning areas fluctuated less when river levels were not changing due to load-following operation. Variable temperature and VHG could affect chum and fall Chinook salmon spawning segregation and incubation success by altering the cues each species uses to select redd sites. Alterations in site selection would result in a breakdown in the spatial segregation of spawning between chum and fall Chinook salmon, which would expose earlier spawning fall Chinook eggs to a greater risk of dislodgement from later spawning chum salmon. Additional research will be required to fully assess the effects of load-following operations on the hyporheic environment and spawning and incubation success of chum and fall Chinook salmon downstream from Bonneville Dam.

13 HYDRO ENERGY↗

A Comparison of Pressure Measurements Between a Full-Scale and a 1/16-Scale F/A-18 Twin Tail During Buffet

In 1993, tail buffet tests were performed on a full-scale, production model F/A-18 in the 80-by-120 Foot Wind Tunnel at NASA Ames Research Center. Steady and unsteady pressures were recorded on both sides of the starboard vertical tail for an angle of attack range of 20 to 40 degrees and at a sideslip range of -16 to 16 degrees at freestream velocities up to 100 knots (Mach 0.15, Reynolds number 1.23 x 10(exp 7)). The aircraft was equipped with removable leading edge extension (LEX) fences that are used in flight to reduce tail buffet loads. In 1995, tail buffet tests were performed on a 1/6-scale F-18 A/B model in the Transonic Dynamics Tunnel (TDT) at NASA Langley Research Center. Steady and unsteady pressures were recorded on both sides of both vertical tails for an angle-of-attack range of 7 to 37 degrees at freestream velocities up to 65 knots (Mach 0.10). Comparisons of steady and unsteady pressures and root bending moments are presented for these wind-tunnel models for selected test cases. Representative pressure and root bending moment power spectra are also discussed, as are selected pressure cross-spectral densities.

Moses, Robert W.↗

Segmented Energy Routing for a Modular AC/DC Hybrid System

This article presents a modular ac/dc system with both distributed and centralized power ports for energy router (ER) applications. In each module of the described system, photovoltaic (PV) power generation units, battery-type energy storage (ES) units, and critical loads are connected to the cascaded H-bridge (CHB)-organized medium-voltage (MV) dc links, with fully distributed low-voltage (LV) dc power ports. Copies of modules share the centralized load bus and interact with an MV ac grid in parallel. Hybrid power port (HPO) assigns flexibility to the system but makes energy routings a necessity for stable operation. In this article, a segmented energy management strategy for the HPO-ER is proposed. In terms of the grid-side power transferring, the system ratings are intentionally designed to match significant power imbalance. Focally, a segmented energy management strategy is proposed to realize fully autonomous energy routing involving MV ac grid, distributed PV generations, distributed battery storages, and LV load. The system is proven to be stable using the derived impedance-based model considering the interaction between power blocks. The feasibility of the topology and control strategy is also verified through software simulation, laboratorial hardware prototype experiment, and hardware-in-the-loop (HIL) emulation.

24 POWER TRANSMISSION AND DISTRIBUTION↗