Search NASA⌕ Search

SEARCH · Search NASA

Results for “single photon source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

A novel method for modeling the neutron time of flight (nTOF) detector response in current mode to inertial confinement fusion experiments.

There are several machines in this country that produce short bursts of neutrons for various applications. A few examples are the Z machine, operated by Sandia National Laboratories in Albuquerque, NM ; the OMEGA Laser Facility at the University of Rochester in Rochester, NY ; and the National Ignition Facility (NIF) operated by the Department of Energy at Lawrence Livermore National Laboratory in Livermore, California . They all incorporate neutron time of flight (nTOF) detectors which measure neutron yield, and the shapes of the waveforms from these detectors contain germane information about the plasma conditions that produce the neutrons. However, the signals can also be %E2%80%9Cclouded%E2%80%9D by a certain fraction of neutrons that scatter off structural components and also arrive at the detectors, thereby making analysis of the plasma conditions more difficult. These detectors operate in current mode - i.e., they have no discrimination, and all the photomultiplier anode charges are integrated rather than counted individually as they are in single event counting. Up to now, there has not been a method for modeling an nTOF detector operating in current mode. MCNP PoliMi was developed in 2002 to simulate neutron and gamma ray detection in a plastic scintillator, which produces a collision data output table about each neutron and photon interaction occurring within the scintillator; however, the post processing code which accompanies MCNP PoliMi assumes a detector operating in single event counting mode and not current mode. Therefore, the idea for this work had been born: could a new post processing code be written to simulate an nTOF detector operating in current mode? And if so, could this process be used to address such issues as the impact of neutron scattering on the primary signal? Also, could it possibly even identify sources of scattering (i.e., structural materials) that could be removed or modified to produce %E2%80%9Ccleaner%E2%80%9D neutron signals? This process was first developed and then applied to the axial neutron time of flight detectors at the Z Facility mentioned above. First, MCNP PoliMi was used to model relevant portions of the facility between the source and the detector locations. To obtain useful statistics, variance reduction was utilized. Then, the resulting collision output table produced by MCNP PoliMi was further analyzed by a MATLAB postprocessing code. This converted the energy deposited by neutron and photon interactions in the plastic scintillator (i.e., nTOF detector) into light output, in units of MeVee%D1%84 (electron equivalent) vs time. The time response of the detector was then folded into the signal via another MATLAB code. The simulated response was then compared with experimental data and shown to be in good agreement. To address the issue of neutron scattering, an %E2%80%9CIdeal Case,%E2%80%9D (i.e., a plastic scintillator was placed at the same distance from the source for each detector location) with no structural components in the problem. This was done to produce as %E2%80%9Cpure%E2%80%9D a neutron signal as possible. The simulated waveform from this %E2%80%9CIdeal Case%E2%80%9D was then compared with the simulated data from the %E2%80%9CFull Scale%E2%80%9D geometry (i.e., the detector at the same location, but with all the structural materials now included). The %E2%80%9CIdeal Case%E2%80%9D was subtracted from the %E2%80%9CFull Scale%E2%80%9D geometry case, and this was determined to be the contribution due to scattering. The time response was deconvolved out of the empirical data, and the contribution due to scattering was then subtracted out of it. A transformation was then made from dN/dt to dN/dE to obtain neutron spectra at two different detector locations.

Nelson, Alan J.↗

Characterization of high-harmonic emission from ZnO up to 11 eV pumped with a Cr:ZnS high-repetition-rate source

Here, we report the measurement of high-order harmonics from a ZnO crystal with photon energies up to 11 eV generated by a high-repetition-rate femtosecond Cr:ZnS laser operating in the mid-infrared at 2–3 μm, delivering few-cycle pulses with multi-watt average power and multi-megawatt peak power. High-focus intensity is achieved in a single pass through the crystal without a buildup cavity or nanostructued pattern for field enhancement. We measure in excess of 10 8 high-harmonic photons/second.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Scalable single-mode surface-emitting laser via open-Dirac singularities

Single-aperture cavities are a key component of lasers that are instrumental for the amplification and emission of a single light mode. However, the appearance of high-order transverse modes as the size of the cavities increases has frustrated efforts to scale-up cavities while preserving single-mode operation since the invention of the laser six decades ago. A suitable physical mechanism that allows single-mode lasing irrespective of the cavity size-a 'scale invariant' cavity or laser-has not been identified yet. Here we propose and demonstrate experimentally that open-Dirac electromagnetic cavities with linear dispersion-which in our devices are realized by a truncated photonic crystal arranged in a hexagonal pattern-exhibit unconventional scaling of losses in reciprocal space, leading to single-mode lasing that is maintained as the cavity is scaled up in size. The physical origin of this phenomenon lies in the convergence of the complex part of the free spectral range in open-Dirac cavities towards a constant governed by the loss rates of distinct Bloch bands, whereas for common cavities it converges to zero as the size grows, leading to inevitable multimode emission. An unconventional flat-envelope fundamental mode locks all unit cells in the cavity in phase, leading to single-mode lasing. We name such sources Berkeley surface-emitting lasers (BerkSELs) and demonstrate that their far-field corresponds to a topological singularity of charge two, in agreement with our theory. Open-Dirac cavities unlock avenues for light-matter interaction and cavity quantum electrodynamics.

42 ENGINEERING↗

STARlight: A Monte Carlo simulation program for ultra-peripheral collisions of relativistic ions

© 2016 Elsevier B.V. Ultra-peripheral collisions (UPCs) have been a significant source of study at RHIC and the LHC. In these collisions, the two colliding nuclei interact electromagnetically, via two-photon or photonuclear interactions, but not hadronically; they effectively miss each other. Photonuclear interactions produce vector meson states or more general photonuclear final states, while two-photon interactions can produce lepton or meson pairs, or single mesons. In these interactions, the collision geometry plays a major role. We present a program, STARlight, that calculates the cross-sections for a variety of UPC final states and also creates, via Monte Carlo simulation, events for use in determining detector efficiency. Program summary Program Title: STARlight (v2.2) Program Files doi: http://dx.doi.org/10.17632/xjpf4rxtbj.1 Licensing provisions: GNU GPLv3 Programming Language: C++ External Routines: PYTHIA 8.2 and DPMJET 3.0 are needed for some final states. Nature of problem: The cross-section for ultra-peripheral collisions is obtained by integrating the photon fluxes in transverse impact parameter space, subject to the requirement (which is also impact parameter dependent) that the colliding nuclei do not interact hadronically. The program is a two step process. First, it calculates the cross-sections for the reaction of interest, as a function of W (photon–Pomeron or two-photon center of mass energy), Y (final state rapidity) and pT (final state transverse momentum). Second, STARlight generates Monte Carlo events which can be used to determine cross-sections within specific kinematic constraints or for studies of detector efficiencies. The second step includes the decay of any unstable particles produced in the reaction, with appropriate consideration of particle spins and parity. It outputs these events in ASCII format. Solution method: The program generates a two dimensional look-up table of the production cross-section as a function of final state rapidity and mass. The dimensions of the table are selectable, allowing the user to choose the desired accuracy. For certain final states, a second two-dimensional look-up table, giving the transverse momentum distribution, as a function of rapidity, is also used. With these look-up tables, the program generates final states. Particle decays and the final angular distributions are calculated for each event. Restrictions: The program is focused on ultra-relativistic collisions at Brookhaven's RHIC (Relativistic Heavy Ion Collider) and CERN's LHC (Large Hadron Collider), with final states that are visible in a central detector. At lower energies (i.e., at the CERN SPS), caution should be exercised because STARlight does not account for the longitudinal momentum transfer to the nucleus; this is larger at low beam energies. References: http://starlight.hepforge.org and references in this article.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Single-photoelectron collection efficiency in 4D ultrafast electron microscopy

In femtosecond (fs) 4D ultrafast electron microscopy (UEM), a tradeoff is made between photoelectrons per packet and time resolution. One consequence of this can be longer-than-desirable acquisition times for low-density packets, and particularly for low repetition rates when complete photothermal dissipation is required. Thus, gaining an understanding of photoelectron trajectories in the gun region is important for identifying factors that limit collection efficiency (CE; fraction of photoelectrons that enter the illumination system). Here, we continue our work on the systematic study of photoelectron trajectories in the gun region of a Thermo Fisher/FEI Tecnai Femto UEM, focusing specifically on CE in the single-electron regime. Using General Particle Tracer, calculated field maps, and the exact architecture of the Tecnai Femto UEM, we simulated the effects of fs laser parameters and key gun elements on CE. The results indicate CE strongly depends upon the laser spot size on the source, the (unbiased) Wehnelt aperture diameter, and the incident photon energy. The CE dispersion with laser spot size is found to be strongly dependent on aperture diameter, being nearly dispersionless for the largest apertures. A gun crossover is also observed, with the beam-waist position being dependent on the aperture diameter, further illustrating that the Wehnelt aperture acts as a simple, fixed electrostatic lens in UEM mode. This work provides further insights into the operational aspects of fs 4D UEM.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Two-Photon Spontaneous Emission in Atomically Thin Plasmonic Nanostructures

The ability to harness light-matter interactions at the few-photon level plays a pivotal role in quantum technologies. Single photons—the most elementary states of light—can be generated on demand in atomic and solid state emitters. Two-photon states are also key quantum assets, but achieving them in individual emitters is challenging because their generation rate is much slower than competing one-photon processes. We demonstrate that atomically thin plasmonic nanostructures can harness two-photon spontaneous emission, resulting in giant far field two-photon production, a wealth of resonant modes enabling tailored photonic and plasmonic entangled states, and plasmon-assisted single-photon creation orders of magnitude more efficient than standard one-photon emission. We unravel the two-photon spontaneous emission channels and show that their spectral line shapes emerge from an intricate interplay between Fano and Lorentzian resonances. Enhanced two-photon spontaneous emission in two-dimensional nanostructures paves the way to an alternative efficient source of light-matter entanglement for on-chip quantum information processing and free-space quantum communications.

36 MATERIALS SCIENCE↗

Structural, Criticality, and Radiation Dose Calculations to support SNF Loading into a DOE Standard Canister

The DOE Standard Canister Demonstration Project includes the development of an internal support structure (ISS) for the 4.6-m long and 45.7-cm diameter canister. This study presents structural evaluations, criticality safety assessments, and dose rate calculations conducted within the scope of the ISS design process to support smooth canister loading operations and to ensure safe storage, transportation, and disposal of Peach Bottom 1 Core II (PB2) and Fort St. Vrain (FSV) SNF, currently stored at the CPP-603 facility of the INL. The ISS includes a 316L stainless steel basket that holds twelve PB2 SNF rods. Further, six individual, 78.7-cm long, 316L stainless steel columns are equally spaced and welded to the inner canister wall at the lower end of the shell. These columns represent the FSV basket and can hold one FSV SNF element. An A92014 T6 aluminum spacer disc is bolted to the bottom plate of the PB2 basket to vertically restrain the FSV SNF element after the PB2 basket is placed inside the canister on top of the FSV basket. The structural evaluations of the ISS followed applicable ASME BPVC.III.3 guidelines and included finite element (FE) analyses of the PB2 basket structure; analyses of welds and bolds; buckling analyses of selected components, and acceptability assessments of the expected basket deformations under loading operations. The criticality safety assessments used the Monte Carlo N-Particle (MCNP) software architecture version 6.2 including ENDF/B-V continuous energy cross-section libraries, considering intact SNF in a single storage overpack or two multi-storage overpack configurations, and intact or failed SNF configured for disposal. The dose rate computations are based on source terms taken from the DOE Spent Fuel Database. The isotopic composition was decay corrected for the year 2022 using the ORIGEN module in the SCALE suite. A 19-group photon spectrum and 27-group neutron-source spectra were generated and used in MCNP to calculate estimated dose-equivalent rates, both on DOE Standard Canister contact and at a radial distance of from the canister surface. The results of this study indicate a structurally sound system that can uphold its criticality safety functions throughout its intended operational phases. Further, they increase confidence that sufficient radiological protection is technically achievable.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Angular independent silicon detector for dosimetry in external beam radiotherapy

Purpose: In this work, the “edgeless” silicon detector technology is investigated, in combination with an innovative packaging solution, to manufacture silicon detectors with negligible angular response. The new diode is also characterized as a dosimeter for radiotherapy with the aim to verify its suitability as a single detector for in vivo dosimetry as well as large area 2D array that does not require angular correction to their response. Methods: For the characterisation of the “edgeless-drop-in” detector technology, a set of samples have been manufactured with different sensitive areas (1 × 1 and 0.5 × 0.5 mm{sup 2}) and different thicknesses (0.1 and 0.5 mm) in four different combinations of top and peripheral p–n junction fabricated on p-type and n-type silicon substrates. The diode probes were tested in terms of percentage depth dose (PDD), dose rate, and linearity and compared to ion chambers. Measurements of the output factor have been compared to film. The angular response of the diodes probes has been tested in a cylindrical PMMA phantom, rotated with bidirectional accuracy of 0.25° under 10 × 10 cm{sup 2} 6 MV Linac photon beam. The radiation hardness has been investigated as well as the effect of radiation damage on the angular and dose rate response of the diode probes when irradiated with photons from a Co-60 gamma source up to dose of 40 kGy. Results: The PDDs measured by the edgeless detectors show an agreement with the data obtained using ion chambers within ±2%. The output factor measured with the smallest area edgeless diodes (0.5 × 0.5 mm{sup 2}—0.1 and 0.5 mm thick) matches EBT3 film to within 2% for square field size from 10 to 0.5 cm side equivalent distance. The dose rate dependence in a dose per pulse range of 0.9 × 10{sup −5}–2.7 × 10{sup −4} Gy/pulse was less than −7% and +300% for diodes fabricated on p-type and n-type substrates, respectively. The edgeless diodes fabricated on the p-type substrate demonstrated degradation of the response as a function of the irradiation dose within 5%–15%, while diodes on the n-type substrate show a variation of approximately 30% after 40 kGy. The angular response of all probes is minimal (within 2%) but the N on N and P on P configurations show the best performances with an angular dependence of ±1.0% between 0° and 180° in the transversal direction. In this configuration, the space charge region of the passive diode extends from the behind and sidewall toward the anode on the top providing beneficial electric field distribution in the peripheral area of the diode. Such performance has also been tested after irradiation by Co-60 up to 40 kGy with no measurable change in angular response. Conclusions: A new edgeless-drop-in silicon diode fabrication and packaging technology has been used to develop detectors that show no significant angular dependence in their response for dosimetry in radiation therapy. From the characterisation of the diodes, proposed in a wide range of different geometries and configurations, the authors recommend the P-on-P detectors in conjunction with “drop in” packaging technology as the candidate for further development as single diode probe or 2D diode array for dosimetry in radiotherapy.

60 APPLIED LIFE SCIENCES↗

Performance of a phonon-mediated kinetic inductance detector at the NEXUS cryogenic facility

Microcalorimeters that leverage microwave kinetic inductance detectors to read out phonon signals in the particle-absorbing target, referred to as kinetic inductance phonon-mediated (KIPM) detectors, offer an attractive detector architecture to probe dark matter (DM) down to the fermionic thermal relic mass limit. A prototype KIPM detector featuring a single aluminum resonator patterned onto a 1-gram silicon substrate was operated in the Northwestern EXerimental Underground Site (NEXUS) low-background facility at Fermilab for characterization and evaluation of this detector architecture’s efficacy for a DM search. An energy calibration was performed by exposing the bare substrate to a pulsed source of 470-nm photons, resulting in a baseline resolution on the energy absorbed by the phonon sensor of 2.1 ± 0.2 eV, a factor of two better than the current state of the art, enabled by quasiparticle lifetimes extending up to 6.5 ms. However, due to the subpercent phonon collection efficiency, the resolution on energy deposited in the substrate is limited to σ E = 318 ± 29 eV. We further model both the signal pulse shape as a function of device temperature to extract quasiparticle lifetimes, and the observed noise spectra.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

HESS J1427−608: AN UNUSUAL HARD, UNBROKEN γ -RAY SPECTRUM IN A VERY WIDE ENERGY RANGE

We report the detection of a GeV γ -ray source that spatially overlaps and is thus very likely associated with the unidentified very high energy (VHE) γ -ray source HESS J1427−608 with the Pass 8 data recorded by the Fermi Large Area Telescope . The photon spectrum of this source is best described by a power law with an index of 1.85 ± 0.17 in the energy range of 3–500 GeV, and the measured flux connects smoothly with that of HESS J1427−608 at a few hundred gigaelectronvolts. This source shows no significant extension and time variation. The broadband GeV to TeV emission over four decades of energies can be well fitted by a single power-law function with an index of 2.0, without obvious indication of spectral cutoff toward high energies. Such a result implies that HESS J1427−608 may be a PeV particle accelerator. We discuss the possible nature of HESS J1427−608 according to the multiwavelength spectral fittings. Given the relatively large errors, either a leptonic or a hadronic model can explain the multiwavelength data from radio to VHE γ -rays. The inferred magnetic field strength is a few micro-Gauss, which is smaller than the typical values of supernova remnants (SNRs) and is consistent with some pulsar wind nebulae (PWNe). On the other hand, the flat γ -ray spectrum is slightly different from typical PWNe but is similar to that of some known SNRs.

79 ASTRONOMY AND ASTROPHYSICS↗

Tracing intermolecular Coulombic decay of carbon-dioxide dimers and oxygen dimers after valence photoionization

In this study, we have conducted an experimental study on the photo double ionization (PDI) of carbon-dioxide dimers at photon energies of 37 and 55 eV and oxygen dimers at photon energies of 38, 41.5, and 46 eV, while focusing on the dissociation dynamics upon single-photon absorption. The investigation was performed by applying the cold-target recoil-ion momentum spectroscopy method in order to collect and record the three-dimensional momenta of the ionic fragments and emitted electrons from the dissociating dimer in coincidence. The kinetic-energy release upon fragmentation and the electron angular distributions in the laboratory and body-fixed frames, as well as the relative electron-electron emission angle, show unambiguous experimental evidence of intermolecular Coulombic decay (ICD) in carbon-dioxide dimers upon photoionization below and above the double-ionization threshold of CO 2 monomers. The PDI of oxygen dimers is less conclusive and shows contributions from ICD and knock-off ionization mechanisms. As for atomic dimers, the present results reveal that ICD in CO 2 dimers after valence PDI can also serve as a source for low-energy electrons, known to be very relevant in biological systems, cells, and tissues.

74 ATOMIC AND MOLECULAR PHYSICS↗

SU-G-BRB-05: Automation of the Photon Dosimetric Quality Assurance Program of a Linear Accelerator

Purpose: To develop an automated method to calculate a linear accelerator (LINAC) photon radiation field size, flatness, symmetry, output and beam quality in a single delivery for flattened (FF) and flattening-filter-free (FFF) beams using an ionization chamber array. Methods: The proposed method consists of three control points that deliver 30×30, 10×10 and 5×5cm{sup 2} fields (FF or FFF) in a step-and-shoot sequence where the number of monitor units is weighted for each field size. The IC Profiler (Sun Nuclear Inc.) with 5mm detector spacing was used for this study. The corrected counts (CCs) were calculated and the locations of the maxima and minima values of the first-order gradient determined data of each sub field. Then, all CCs for each field size are summed in order to obtain the final profiles. For each profile, the radiation field size, symmetry, flatness, output factor and beam quality were calculated. For field size calculation, a parameterized gradient method was used. For method validation, profiles were collected in the detector array both, individually and as part of the step-and-shoot plan, with 9.9cm buildup for FF and FFF beams at 90cm source-to-surface distance. The same data were collected with the device (plus buildup) placed on a movable platform to achieve a 1mm resolution. Results: The differences between the dosimetric quantities calculated from both deliveries, individually and step-and-shoot, were within 0.31±0.20% and 0.04±0.02mm. The differences between the calculated field sizes with 5mm and 1mm resolution were ±0.1mm. Conclusion: The proposed single delivery method proved to be simple and efficient in automating the photon dosimetric monthly and annual quality assurance.

61 RADIATION PROTECTION AND DOSIMETRY↗

Transmission diamond imaging detector

Many modern synchrotron techniques are trending toward use of high flux beams and/or beams which require enhanced stability and precise understanding of beam position and intensity from the front end of the beamline all the way to the sample. For high flux beams, major challenges include heat load management in optics (including the vacuum windows) and a mechanism of real-time volumetric measurement of beam properties such as flux, position, and morphology. For beam stability in these environments, feedback from such measurements directly to control systems for optical elements or to sample positioning stages would be invaluable. To address these challenges, we are developing diamond-based instrumented vacuum windows with integrated volumetric x-ray intensity, beam profile and beam-position monitoring capabilities. A 50 µm thick single crystal diamond has been lithographically patterned to produce 60 µm pixels, creating a >1kilopixel free-standing transmission imaging detector. This device, coupled with a custom, FPGA-based readout, has been used to image both white and monochromatic x-ray beams and capture the last x-ray photons at the National Synchrotron Light Source (NSLS). This technology will form the basis for the instrumented end-station window of the x-ray footprinting beamline (XFP) at NSLS-II.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Implementation of Talbot–Lau x-ray deflectometry in the pulsed power environment using a copper X-pinch backlighter

A Talbot–Lau x-ray deflectometer can map electron density gradients in high energy density plasmas, as well as provide information about plasma elemental composition through single-image x-ray refraction and attenuation measurements. A new adaptation to a pulsed power environment used backlighting from copper X-pinches, allowing for electron density mapping of a low-Z object. Even though the X-pinch backlighter is not properly optimized for emitting x-rays in terms of source size and photon fluence, Moire fringe patterns with contrast up to 14% and fringe shift due to refraction on a beryllium object are obtained. Due to the proximity of the deflectometer with the X-pinch (~6 cm), it is shown that a protective filter is required to avoid damage in the closest (i.e., source) grating due to both plasma debris and mechanical shock. Regarding grating survival, these did not show any damage due to the intense magnetic field or heating induced by plasma radiation. Electron density on beryllium was measured with a difference lower than 16%. The areal electron density mapping of the sample was limited by source size characteristics, in similarity to transmission radiography. These results show the potential of plasma electron density as well as material mapping through Talbot–Lau x-ray deflectometry in a pulsed power environment.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Constraints on the Location of the Gamma-ray Emission Region for the Gamma-ray-loud Radio Source GB 1310+487

We employ a single-zone leptonic jet model, with synchrotron, synchrotron self-Compton, and external Compton (EC) processes, to reproduce the quasi-simultaneous multi-wavelength spectral energy distributions in active and quiescent states of the narrow-line gamma-ray-loud radio source GB 1310+487. In the case of the EC process, the external seed photons from both the broad line region (BLR) and the dust torus are considered by assuming that the gamma-ray emission region is located at the outside boundary of the BLR and inside the dust torus. Comparing the energy density of external photon fields U{sub BLR} obtained by model fitting with that constrained from the BLR observations. We find that the location of the gamma-ray-emitting region of GB 1310+487 can be tightly constrained at the outer edge of the BLR (the dissipation distance of the γ-ray emission region from central black hole r{sub diss}∼ a few times of R{sub BLR}). The ratio of magnetic energy and emitting-electron energy in the radiation blob (ϵ{sub B}=L{sub B}/L{sub e}) is gradually increased from Flare 1, to Flare 2, to Post-flare, where the magnetic energy increases and the matter energy decreases. These results suggest that the conversion of the magnetic field and the matter (radiation electrons) energy and the location of the γ-ray emission region (or ambient photon field) may play an important role in different radiation states of GB 1310+487.

79 ASTRONOMY AND ASTROPHYSICS↗

Growth Dynamics of Millimeter-Sized Single-Crystal Hexagonal Boron Nitride Monolayers on Secondary Recrystallized Ni (100) Substrates

The outstanding physical properties of 2D materials have sparked continuous research interest in exploiting these materials for next-generation high-performance electronic and photonic technology. Scalable synthesis of high-quality large-area 2D hexagonal boron nitride (h-BN) is a crucial step toward the ultimate success of many of these applications. In this work, a synthetic approach in which secondary recrystallized Ni (100) substrates underwent a carburization process, followed by the growth of h-BN in a molecular beam epitaxy system is designed. The h-BN growth dynamics is studied by tuning different growth parameters including the substrate temperature, and the boron and nitrogen source flux ratio. With assistance from density functional theory calculations, the role of interstitial C atoms in promoting h-BN growth by enhancing the catalytic effect of the transition metal, which lowers the nucleation activation energy barrier, is rationalized. Furthermore, through the control of the growth parameters, a single-crystal h-BN monolayer domain as large as 1.4 mm in edge length is achieved. In addition, a high-quality, continuous, large-area h-BN single-layer film with a breakdown electric field of 9.75 MV cm -1 is demonstrated. The high value of the breakdown electric field suggests that single-layer h-BN has extraordinary dielectric strength for high-performance 2D electronics applications.

2D↗

Unidentified sources in the Fermi-LAT second source catalog: the case for DM subhalos

The Large Area Telescope (LAT) aboard the Fermi satellite allows us to study the high-energy γ-ray sky with unprecedented sensitivity. However, the origin of 31% of the detected γ-ray sources remains unknown. This population of unassociated γ-ray sources may contain new object classes, among them sources of photons from self-annihilating or decaying non-baryonic dark matter. Fermi-LAT might be capable to detect up to a few of these dark matter subhalos as faint and moderately extended γ-ray sources with a temporally steady high-energy emission. After applying corresponding selection cuts to the second year Fermi catalog 2FGL, we investigate 13 candidate objects in more detail including their multi-wavelength properties in the radio, infrared, optical, UV, and X-ray bands. For the γ-ray band, we analyze both the 24-month and 42-month Fermi-LAT data sets. We probe the γ-ray spectra for indications of a spectral cutoff, which singles out four sources of particular interest. We find all sources to be compatible with a point-source scenario. Multi-wavelength associations and, in particular, their infrared color-color data indicate no source to be compatible with a dark matter origin, and we find the majority of the candidates to probably originate from faint, high-frequency peaked BL Lac type objects. We discuss possibilities to further investigate source candidates and future prospects to search for dark matter subhalos.

79 ASTRONOMY AND ASTROPHYSICS↗

Development of a series of Korean pediatric and adult head computational phantoms and application to nuclear medicine dosimetry - Paper 26

Over the past decades, advances in Single Photon Emission Computed Tomography (SPECT) and Positron Emission Tomography (PET) imaging techniques and an increasing number of new radiopharmaceuticals have resulted in a surge of neuroimaging applications in nuclear medicine on pediatric and adult patients. It is not feasible to directly measure the absorbed dose to the organs of the human body from nuclear medicine procedures. The formalism of the Medical Internal Radiation Dose (MIRD) committee of the Society of Nuclear Medicine has been adopted as the calculation method to estimate radiation dose to target organs from radionuclides distributed in source organs. The absorbed dose to a target organ from different types of radionuclides distributed within source organs can be estimated by the products of the time-integrated activity in each source region and organ dose conversion coefficients, called S values (Gy/MBq-s). S values are computed from a comprehensive set of Specific Absorbed Fraction (SAF), which are calculated from computational human phantoms with realistic anatomical structures coupled with Monte Carlo transport technique. The current SAF data for pediatric and adult head and brain dosimetry is based on a series of stylized computational phantoms. However, dosimetric errors caused by the unrealistic anatomy of stylized phantoms in internal dosimetry calculations have been reported by several studies. In the current study, we developed a series of realistic computational head phantoms representing 6, 9, 12, 15, and 22-year-old standard Korean males, and computed a comprehensive set of SAFs using the phantoms coupled with Monte Carlo transport technique. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗