Search NASA⌕ Search

SEARCH · Search NASA

Results for “slicing methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

TH-AB-207A-12: CT Lung Cancer Screening and the Effects of Further Dose Reduction On CAD Performance

Purpose: CT lung screening is already performed at low doses. In this study, we investigated the effects of further dose reduction on a lung-nodule CAD detection algorithm. Methods: The original raw CT data and images from 348 patients were obtained from our local database of National Lung Screening Trial (NLST) cases. 61 patients (17.5%) had at least one nodule reported on the NLST reader forms. All scans were acquired with fixed mAs (25 for standard-sized patients, 40 for large patients) on a 64-slice scanner (Sensation 64, Siemens Healthcare). All images were reconstructed with 1-mm slice thickness, B50 kernel. Based on a previously-published technique, we added noise to the raw data to simulate reduced-dose versions of each case at 50% and 25% of the original NLST dose (i.e. approximately 1.0 and 0.5 mGy CTDIvol). For each case at each dose level, a CAD detection algorithm was run and nodules greater than 4 mm in diameter were reported. These CAD results were compared to “truth”, defined as the approximate nodule centroids from the NLST forms. Sensitivities and false-positive rates (FPR) were calculated for each dose level, with a sub-analysis by nodule LungRADS category. Results: For larger category 4 nodules, median sensitivities were 100% at all three dose levels, and mean sensitivity decreased with dose. For the more challenging category 2 and 3 nodules, the dose dependence was less obvious. Overall, mean subject-level sensitivity varied from 38.5% at 100% dose to 40.4% at 50% dose, a difference of only 1.9%. However, median FPR quadrupled from 1 per case at 100% dose to 4 per case at 25% dose. Conclusions: Dose reduction affected nodule detectability differently depending on the LungRADS category, and FPR was very sensitive at sub-screening levels. Care should be taken to adapt CAD for the very challenging noise characteristics of screening. Funding support: NIH U01 CA181156; Disclosures (McNitt-Gray): Institutional research agreement, Siemens Healthcare; Past recipient, research grant support, Siemens Healthcare; Consultant, Toshiba America Medical Systems; Consultant, Samsung Electronics.

60 APPLIED LIFE SCIENCES↗

SU-E-J-263: Dosimetric Analysis On Breast Brachytherapy Based On Deformable Image Registration

Purpose: To quantitatively compare and evaluate the dosimetry difference between breast brachytherapy protocols with different fractionation using deformable image registration. Methods: The accumulative dose distribution for multiple breast brachytherapy patients using four different applicators: Contura, Mammosite, Savi, and interstitial catheters, under two treatment protocols: 340cGy by 10 fractions in 5 days and 825cGy by 3 fractions in 2days has been reconstructed using a two stage deformable image registration approach. For all patients, daily CT was acquired with the same slice thickness (2.5mm). In the first stage, the daily CT images were rigidly registered to the initial planning CT using the registration module in Eclipse (Varian) to align the applicators. In the second stage, the tissues surrounding the applicator in the rigidly registered daily CT image were non-rigidly registered to the initial CT using a combination of image force and the local constraint that enforce zero normal motion on the surface of the applicator, using a software developed in house. We calculated the dose distribution in the daily CTs and deformed them using the final registration to convert into the image domain of the initial planning CT. The accumulative dose distributions were evaluated by dosimetry parameters including D90, V150 and V200, as well as DVH. Results: Dose reconstruction results showed that the two day treatment has a significant dosimetry improvement over the five day protocols. An average daily drop of D90 at 1.3% of the prescription dose has been observed on multiple brachytherapy patients. There is no significant difference on V150 and V200 between those two protocols. Conclusion: Brachytherapy with higher fractional dose and less fractions has an improved performance on being conformal to the dose distribution in the initial plan. Elongated brachytherapy treatments need to consider the dose uncertainty caused by the temporal changes of the soft tissue.

60 APPLIED LIFE SCIENCES↗

SU-F-R-22: Malignancy Classification for Small Pulmonary Nodules with Radiomics and Logistic Regression

Purpose: We conducted a retrospective study of Radiomics research for classifying malignancy of small pulmonary nodules. A machine learning algorithm of logistic regression and open research platform of Radiomics, IBEX (Imaging Biomarker Explorer), were used to evaluate the classification accuracy. Methods: The training set included 100 CT image series from cancer patients with small pulmonary nodules where the average diameter is 1.10 cm. These patients registered at Chang Gung Memorial Hospital and received a CT-guided operation of lung cancer lobectomy. The specimens were classified by experienced pathologists with a B (benign) or M (malignant). CT images with slice thickness of 0.625 mm were acquired from a GE BrightSpeed 16 scanner. The study was formally approved by our institutional internal review board. Nodules were delineated and 374 feature parameters were extracted from IBEX. We first used the t-test and p-value criteria to study which feature can differentiate between group B and M. Then we implemented a logistic regression algorithm to perform nodule malignancy classification. 10-fold cross-validation and the receiver operating characteristic curve (ROC) were used to evaluate the classification accuracy. Finally hierarchical clustering analysis, Spearman rank correlation coefficient, and clustering heat map were used to further study correlation characteristics among different features. Results: 238 features were found differentiable between group B and M based on whether their statistical p-values were less than 0.05. A forward search algorithm was used to select an optimal combination of features for the best classification and 9 features were identified. Our study found the best accuracy of classifying malignancy was 0.79±0.01 with the 10-fold cross-validation. The area under the ROC curve was 0.81±0.02. Conclusion: Benign nodules may be treated as a malignant tumor in low-dose CT and patients may undergo unnecessary surgeries or treatments. Our study may help radiologists to differentiate nodule malignancy for low-dose CT.

60 APPLIED LIFE SCIENCES↗

SU-F-T-171: Manufacturing Cost Effective Heterogeneous Phantoms for Use in Proton Therapy

Purpose: To study the feasibility of 3D printing cost effective heterogeneous phantoms for use in proton therapy treatment planning quality assurance. Methods: A desktop 3D printer was utilized to create a series of 2 cm × 2 cm × 4 cm PLA plastic blocks of varying fill materials and hexagonal fill pattern. The blocks were than tested when filled with air, polyurethane foam, paraffin, silicone, and caulk of calcium carbonate – acrylic polymer blend. The blocks were evaluated with a “GE Lightspeed” 16 slice CT scanner and average CT# of the materials’ centers evaluated. Blocks were then placed into a custom aperture fitted to a Mevion Proton system to determine the relative stopping power of each. Scans were performed in water tank with Marcus type parallel plate chamber under a beam with a range of 15 cm and modulation of 2 cm. Shifts in range occurring relative to the 80% distal edge of the open SOBP were evaluated. Results: The CT#s of the blocks were plotted against their measured relative stopping power. This curve was compared to that which is in clinical use. While the trend agrees generally, specific differences between the relative stopping powers were as great as 10%. Conclusion: We have demonstrated that it is possible to utilize different cost effective materials in the manufacturing of phantoms for use in proton therapy. While different materials may provide better agreement to established calibration curves, a custom curve specific to the materials used may be utilized to accurately predict proton treatment dose distributions.

60 APPLIED LIFE SCIENCES↗

Examination of Multiple Lithologies Within the Primitive Ordinary Chondrite NWA 5717

Northwest Africa 5717 is a primitive (subtype 3.05) ungrouped ordinary chondrite which contains two apparently distinct lithologies. In large cut meteorite slabs, the darker of these, lithology A, looks to host the second, much lighter in color, lithology B (upper left, Fig. 1). The nature of the boundary between the two is uncertain, ranging from abrupt to gradational and not always following particle boundaries. The distinction between the lithologies, beyond the obvious color differences, has been supported by a discrepancy in oxygen isotopes and an incongruity in the magnesium contents of chondrule olivine. Here, quantitative textural analysis and mineralogical methods have been used to investigate the two apparent lithologies within NWA 5717. Olivine grains contained in a thin section from NWA 7402, thought to be paired to 5717, were also measured to re-examine the distinct compositional range among the light and dark areas. Procedure: Particles from a high-resolution mosaic image of a roughly 13x15cm slice of NWA 5717 were traced in Adobe Photoshop. Due to the large size of the sample, visually representative regions of each lithology were chosen to be analyzed. The resulting layers of digitized particles were imported into ImageJ, which was used to measure their area, along with the axes, the angle from horizontal, and the centroid coordinates of ellipses fitted to each particle following the approach. Resulting 2D pixel areas were converted to spherical diameters employing the unfolding algorithm, which outputs a 3D particle size distribution based on digitized 2D size frequency data. Spatstat was used to create kernel density plots of the centroid coordinates for each region. X-ray compositional maps, microprobe analyses, and Mossbauer spectroscopy was conducted on a thin section of NWA 7402, tentatively paired to NWA 5717.

Cato, M. J.↗

Reference guide to WPP version 2.0

WPP is a computer program for simulating seismic wave propagation on parallel machines. WPP solves the governing equations in second order formulation using a node-based finite difference approach. The basic numerical method is described in [9]. WPP implements substantial capabilities for 3-D seismic modeling, with a free surface condition on the top boundary, non-reflecting far-field boundary conditions on the other boundaries, point force and point moment tensor source terms with many predefined time dependencies, fully 3-D heterogeneous material model specification, output of synthetic seismograms in the SAC [4] format, output of GMT [11] scripts for laying out simulation information on a map, and output of 2-D slices of (derived quantites of) the solution field as well as the material model. Version 2.0 of WPP allows the free surface boundary condition to be imposed on a curved topography. For this purpose a curvilinear mesh is used near the free surface, extending into the computational domain down to a user specified level. The elastic wave equations and the free surface boundary conditions are discretized on the curvilinear mesh using the energy conserving technique described in [2]. A curvilinear mesh generator is built into WPP and the curvilinear mesh is automatically generated from the topography. Below the curvilinear grid, the elastic wave equation is discretized on Cartesian meshes, which leads to a more computationally efficient algorithm. In version 2.0 of WPP, Cartesian local mesh refinement can be used to make the computational mesh finer near the free surface, where more resolution often is needed to resolve short wave lenghts in the solution, for example in sedimentary basins. The mesh refinement is performed in the vertical direction and each Cartesian grid is constructed from user specified refinement levels. In this approach, the grid size in all three spatial directions is doubled across each mesh refinement interface, leading to substantial savings in memory and computational effort. The energy conserving mesh refinement coupling method described in [10] is used to handle the hanging nodes along the refinement interface. The examples subdirectory of the WPP source distribution contains several examples and validation tests. Many Matlab/octave scripts are provided in the tools directory.

58 GEOSCIENCES↗

Dosimetric equivalence of nonstandard HDR brachytherapy catheter patterns

Purpose: To determine whether alternative high dose rate prostate brachytherapy catheter patterns can result in similar or improved dose distributions while providing better access and reducing trauma. Materials and Methods: Standard prostate cancer high dose rate brachytherapy uses a regular grid of parallel needle positions to guide the catheter insertion. This geometry does not easily allow the physician to avoid piercing the critical structures near the penile bulb nor does it provide position flexibility in the case of pubic arch interference. This study used CT datasets with 3 mm slice spacing from ten previously treated patients and digitized new catheters following three hypothetical catheter patterns: conical, bi-conical, and fireworks. The conical patterns were used to accommodate a robotic delivery using a single entry point. The bi-conical and fireworks patterns were specifically designed to avoid the critical structures near the penile bulb. For each catheter distribution, a plan was optimized with the inverse planning algorithm, IPSA, and compared with the plan used for treatment. Irrelevant of catheter geometry, a plan must fulfill the RTOG-0321 dose criteria for target dose coverage (V{sub 100}{sup Prostate}>90%) and organ-at-risk dose sparing (V{sub 75}{sup Bladder}<1 cc, V{sub 75}{sup Rectum}<1 cc, V{sub 125}{sup Urethra}<<1 cc). Results: The three nonstandard catheter patterns used 16 nonparallel, straight divergent catheters, with entry points in the perineum. Thirty plans from ten patients with prostate sizes ranging from 26 to 89 cc were optimized. All nonstandard patterns fulfilled the RTOG criteria when the clinical plan did. In some cases, the dose distribution was improved by better sparing the organs-at-risk. Conclusion: Alternative catheter patterns can provide the physician with additional ways to treat patients previously considered unsuited for brachytherapy treatment (pubic arch interference) and facilitate robotic guidance of catheter insertion. In addition, alternative catheter patterns may decrease toxicity by avoidance of the critical structures near the penile bulb while still fulfilling the RTOG criteria.

61 RADIATION PROTECTION AND DOSIMETRY↗

A controlled statistical study to assess measurement variability as a function of test object position and configuration for automated surveillance in a multicenter longitudinal COPD study (SPIROMICS)

Purpose: A test object (phantom) is an important tool to evaluate comparability and stability of CT scanners used in multicenter and longitudinal studies. However, there are many sources of error that can interfere with the test object-derived quantitative measurements. Here the authors investigated three major possible sources of operator error in the use of a test object employed to assess pulmonary density-related as well as airway-related metrics. Methods: Two kinds of experiments were carried out to assess measurement variability caused by imperfect scanning status. The first one consisted of three experiments. A COPDGene test object was scanned using a dual source multidetector computed tomographic scanner (Siemens Somatom Flash) with the Subpopulations and Intermediate Outcome Measures in COPD Study (SPIROMICS) inspiration protocol (120 kV, 110 mAs, pitch = 1, slice thickness = 0.75 mm, slice spacing = 0.5 mm) to evaluate the effects of tilt angle, water bottle offset, and air bubble size. After analysis of these results, a guideline was reached in order to achieve more reliable results for this test object. Next the authors applied the above findings to 2272 test object scans collected over 4 years as part of the SPIROMICS study. The authors compared changes of the data consistency before and after excluding the scans that failed to pass the guideline. Results: This study established the following limits for the test object: tilt index ≤0.3, water bottle offset limits of [−6.6 mm, 7.4 mm], and no air bubble within the water bottle, where tilt index is a measure incorporating two tilt angles around x- and y-axis. With 95% confidence, the density measurement variation for all five interested materials in the test object (acrylic, water, lung, inside air, and outside air) resulting from all three error sources can be limited to ±0.9 HU (summed in quadrature), when all the requirements are satisfied. The authors applied these criteria to 2272 SPIROMICS scans and demonstrated a significant reduction in measurement variation associated with the test object. Conclusions: Three operator errors were identified which significantly affected the usability of the acquired scan images of the test object used for monitoring scanner stability in a multicenter study. The authors’ results demonstrated that at the time of test object scan receipt at a radiology core laboratory, quality control procedures should include an assessment of tilt index, water bottle offset, and air bubble size within the water bottle. Application of this methodology to 2272 SPIROMICS scans indicated that their findings were not limited to the scanner make and model used for the initial test but was generalizable to both Siemens and GE scanners which comprise the scanner types used within the SPIROMICS study.

60 APPLIED LIFE SCIENCES↗

SU-F-R-48: Early Prediction of Pathological Response of Locally Advanced Rectal Cancer Using Perfusion CT:A Prospective Clinical Study

Purpose: To prospectively evaluate the tumor vascularity assessed by perfusion CT for prediction of chemo-radiation treatment (CRT) response in locally advanced rectal cancer (LARC). Methods: Eighteen consecutive patients (61.9±8.8 years, from March–June 2015) diagnosed with LARC who underwent 6–8 weeks CRT followed by surgery were included. The pre-treatment perfusion CT was acquired after a 5s delay of contrast agent injection for 45s with 1s interval. A total of 7-cm craniocaudal range covered the tumor region with 3-mm slice thickness. The effective radiation dose is around 15mSv, which is about 1.5 the conventional abdomen/pelvis CT dose. The parametric map of blood flow (BF), blood volume (BV), mean transit time (MTT), permeability (PMB), and maximum intensity map (MIP) were obtained from commercial software (Syngo-CT 2011A, Siemens). An experienced radiation oncologist outlined the tumor based on the pre-operative MR and pathologic residual region, but was blinded with regards to pathological tumor stage. The perfusion parameters were compared to histopathological response quantified by tumor regression grade as good-responder (GR, TRG 0-1) vs. non-good responder (non-GR). Furthermore, the predictive value for pathological complete response (pCR) was also investigated. Results: Both BV (p=0.02) and MTT (P=0.02) was significantly higher and permeambility was lower (p=0.004) in the good responders. The BF was higher in GR group but not statistically significant. Regarding the discrimination of pCR vs non-pCR, the BF was higher in the pCR group (p=0.08) but none of those parameters showed statistically significant differences. Conclusion: BV and MTT can discriminate patients with a favorable response from those that fail to respond well, potentially selecting high-risk patients with resistant tumors that may benefit from an aggressive preoperative treatment approach. However, future studies with more patient data are needed to verify the prognostic value of perfusion CT especially for pCR prediction. This work is supported by the National High-tech R&D program for Young Scientists by the Ministry of Science and Technology of China (Grant No. 2015AA020917), Natural Science Foundation of China (NSFC Grant No. 81201091).

60 APPLIED LIFE SCIENCES↗

SU-C-206-07: A Practical Sparse View Ultra-Low Dose CT Acquisition Scheme for PET Attenuation Correction in the Extended Scan Field-Of-View

Purpose: To further reduce CT dose, a practical sparse-view acquisition scheme is proposed to provide the same attenuation estimation as higher dose for PET imaging in the extended scan field-of-view. Methods: CT scans are often used for PET attenuation correction and can be acquired at very low CT radiation dose. Low dose techniques often employ low tube voltage/current accompanied with a smooth filter before backprojection to reduce CT image noise. These techniques can introduce bias in the conversion from HU to attenuation values, especially in the extended CT scan field-of-view (FOV). In this work, we propose an ultra-low dose CT technique for PET attenuation correction based on sparse-view acquisition. That is, instead of an acquisition of full amount of views, only a fraction of views are acquired. We tested this technique on a 64-slice GE CT scanner using multiple phantoms. CT scan FOV truncation completion was performed based on the published water-cylinder extrapolation algorithm. A number of continuous views per rotation: 984 (full), 246, 123, 82 and 62 have been tested, corresponding to a CT dose reduction of none, 4x, 8x, 12x and 16x. We also simulated sparse-view acquisition by skipping views from the fully-acquired view data. Results: FBP reconstruction with Q. AC filter on reduced views in the full extended scan field-of-view possesses similar image quality to the reconstruction on acquired full view data. The results showed a further potential for dose reduction compared to the full acquisition, without sacrificing any significant attenuation support to the PET. Conclusion: With the proposed sparse-view method, one can potential achieve at least 2x more CT dose reduction compared to the current Ultra-Low Dose (ULD) PET/CT protocol. A pre-scan based dose modulation scheme can be combined with the above sparse-view approaches, which can even further reduce the CT scan dose during a PET/CT exam.

60 APPLIED LIFE SCIENCES↗

SU-G-IeP4-11: Monitoring Tumor Growth in Subcutaneous Murine Tumor Model in Vivo: A Comparison Between MRI and Small Animal CT

Purpose: The purpose of the study is to compare the volume measurement of subcutaneous tumors in mice with different imaging platforms, namely a GE MRI and a Sofie-Biosciences small animal CT scanner. Methods: A549 human lung carcinoma cells and FaDu human head and neck squamous cell carcinoma cells were implanted subcutaneously into flanks of nude mice. Three FaDu tumors and three A549 tumors were included in this study. The MRI scans were done with a GE Signa 1.5 Tesla MR scanner using a fast T2-weighted sequence (70mm FOV and 1.2mm slice thickness), while the CT scans were done with the CT scanner on a Sofie-Biosciences G8 PET/CT platform dedicated for small animal studies (48mm FOV and 0.2mm slice thickness). Imaging contrast agent was not used in this study. Based on the DICOM images from MRI and CT scans, the tumors were contoured with Philips DICOM Viewer and the tumor volumes were obtained by summing up the contoured area and multiplied by the slice thickness. Results: The volume measurements based on the CT scans agree reasonably with that obtained with MR images for the subcutaneous tumors. The mean difference in the absolute tumor volumes between MRI- and CT-based measurements was found to be −6.2% ± 1.0%, with the difference defined as (VMR – VCT)*100%/VMR. Furthermore, we evaluated the normalized tumor volumes, which were defined for each tumor as V/V{sub 0} where V{sub 0} stands for the volume from the first MR or CT scan. The mean difference in the normalized tumor volumes was found to be 0.10% ± 0.96%. Conclusion: Despite the fact that the difference between normal and abnormal tissues is often less clear on small animal CT images than on MR images, one can still obtain reasonable tumor volume information with the small animal CT scans for subcutaneous murine xenograft models.

60 APPLIED LIFE SCIENCES↗

First Observations from the SPICE EUV Spectrometer on Solar Orbiter

Aims. We present first science observations taken during the commissioning activities of the Spectral Imaging of the Coronal Environment (SPICE) instrument on the ESA/NASA Solar Orbiter mission. SPICE is a high-resolution imaging spectrometer operating at extreme ultraviolet (EUV) wavelengths. In this paper we illustrate the possible types of observations to give prospective users a better understanding of the science capabilities of SPICE. Methods. We have reviewed the data obtained by SPICE between April and June 2020 and selected representative results obtained with different slits and a range of exposure times between 5 s and 180 s. Standard instrumental corrections have been applied to the raw data. Results. The paper discusses the first observations of the Sun on different targets and presents an example of the full spectra from the quiet Sun, identifying over 40 spectral lines from neutral hydrogen and ions of carbon, oxygen, nitrogen, neon, sulphur, magnesium, and iron. These lines cover the temperature range between 20,000 K and 1 million K (10MK in flares), providing slices of the Sun’s atmosphere in narrow temperature intervals. We provide a list of count rates for the 23 brightest spectral lines. We show examples of raster images of the quiet Sun in several strong transition region lines, where we have found unusually bright, compact structures in the quiet Sun network, with extreme intensities up to 25 times greater than the average intensity across the image. The lifetimes of these structures can exceed 2.5 hours. We identify them as a transition region signature of coronal bright points and compare their areas and intensity enhancements. We also show the first above-limb measurements with SPICE above the polar limb in C III,O VI, and Ne VIII lines, and far off limb measurements in the equatorial plane in Mg IX, Ne VIII, and O VI lines. We discuss the potential to use abundance diagnostics methods to study the variability of the elemental composition that can be compared with in situ measurements to help confirm the magnetic connection between the spacecraft location and the Sun’s surface, and locate the sources of the solar wind. Conclusions. The SPICE instrument successfully performs measurements of EUV spectra and raster images that will make vital contributions to the scientific success of the Solar Orbiter mission

Sun: UV radiation↗

TRP Cutter Head Improvement

The current Target Rod Preparation (TRP) Cutter Head suffers from overheating problems during TPBAR breaching operations. The overheating leads to work stoppage due to the periodic need to allow the TRP Cutter Head motor to cool. This work stoppage and allowance for cooldown of the motor leads to a very inefficient TPBAR breaching process. Due to the increased need for Tritium gas, the system must be improved to increase the efficiency of the TPBAR breaching process. The project would include the following major steps: Determine likely causes of overheating of the TRP cutter head motor. Identify and research methods for cooling currently installed motor. Identify and research alternate motors for TRP cutter head. Procure a new motor for testing. Perform TPBAR breaching mockup testing with new motor. Write report on results and recommendations on potential path forward.

42 ENGINEERING↗

Inter- and Intra-Observer Variability in Prostate Definition With Tissue Harmonic and Brightness Mode Imaging

Purpose: The objective of this study was to compare the relative utility of tissue harmonic (H) and brightness (B) transrectal ultrasound (TRUS) images of the prostate by studying interobserver and intraobserver variation in prostate delineation. Methods and Materials: Ten patients with early-stage disease were randomly selected. TRUS images of prostates were acquired using B and H modes. The prostates on all images were contoured by an experienced radiation oncologist (RO) and five equally trained observers. The observers were blinded to information regarding patient and imaging mode. The volumes of prostate glands and areas of midgland slices were calculated. Volumes contoured were compared among the observers and between observer group and RO. Contours on one patient were repeated five times by four observers to evaluate the intraobserver variability. Results: A one-sample Student t-test showed the volumes outlined by five observers are in agreement (p > 0.05) with the RO. Paired Student t-test showed prostate volumes (p = 0.008) and midgland areas (p = 0.006) with H mode were significantly smaller than that with B mode. Two-factor analysis of variances showed significant interobserver variability (p < 0.001) in prostate volumes and areas. Inter- and intraobserver consistency was quantified as the standard deviation of mean volumes and areas, and concordance indices. It was found that for small glands ({<=}35 cc) H mode provided greater interobserver consistency; however, for large glands ({>=}35 cc), B mode provided more consistent estimates. Conclusions: H mode provided superior inter- and intraobserver agreement in prostate volume definition for small to medium prostates. In large glands, H mode does not exhibit any additional advantage. Although harmonic imaging has not proven advantageous for all cases, its utilization seems to be judicious for small prostates.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Magnetic resonance visualization of conductive structures by sequence-triggered direct currents and spin-echo phase imaging

Purpose: Instrument visualization in interventional magnetic resonance imaging (MRI) is commonly performed via susceptibility artifacts. Unfortunately, this approach suffers from limited conspicuity in inhomogeneous tissue and disturbed spatial encoding. Also, susceptibility artifacts are controllable only by sequence parameters. This work presents the basics of a new visualization method overcoming such problems by applying sequence-triggered direct current (DC) pulses in spin-echo (SE) imaging. SE phase images allow for background free current path localization. Methods: Application of a sequence-triggered DC pulse in SE imaging, e.g., during a time period between radiofrequency excitation and refocusing, results in transient field inhomogeneities. Dependent on the additional z-magnetic field from the DC, a phase offset results despite the refocusing pulse. False spatial encoding is avoided by DC application during periods when read-out or slice-encoding gradients are inactive. A water phantom containing a brass conductor (water equivalent susceptibility) and a titanium needle (serving as susceptibility source) was used to demonstrate the feasibility. Artifact dependence on current strength and orientation was examined. Results: Without DC, the brass conductor was only visible due to its water displacement. The titanium needle showed typical susceptibility artifacts. Applying triggered DC pulses, the phase offset of spins near the conductor appeared. Because SE phase images are homogenous also in regions of persistent field inhomogeneities, the position of the conductor could be determined with high reliability. Artifact characteristic could be easily controlled by amperage leaving sequence parameters unchanged. For an angle of 30° between current and static field visualization was still possible. Conclusions: SE phase images display the position of a conductor carrying pulsed DC free from artifacts caused by persistent field inhomogeneities. Magnitude and phase images are acquired simultaneously under the same conditions without the use of extra measurement time. The presented technique offers many advantages for precise instrument localization in interventional MRI.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-424: Feasibility of 3D Printed Radiological Equivalent Customizable Tissue Like Materials

Purpose: To investigate the feasibility of 3D printing CT# specific radiological equivalent tissue like materials. Methods: A desktop 3D printer was utilized to create a series of 3 cm x 3 cm x 2 cm PLA plastic blocks of varying fill densities. The fill pattern was selected to be hexagonal (Figure 1). A series of blocks was filled with paraffin and compared to a series filled with air. The blocks were evaluated with a “GE Lightspeed” 16 slice CT scanner and average CT# of the centers of the materials was determined. The attenuation properties of the subsequent blocks were also evaluated through their isocentric irradiation via “TrueBeam” accelerator under six beam energies. Blocks were placed upon plastic-water slabs of 4 cm in thickness assuring electronic equilibrium and data was collected via Sun Nuclear “Edge” diode detector. Relative changes in dose were compared with those predicted by Varian “Eclipse” TPS. Results: The CT# of 3D printed blocks was found to be a controllable variable. The fill material was able to narrow the range of variability in each sample. The attenuation of the block tracked with the density of the total fill structure. Assigned CT values in the TPS were seen to fall within an expected range predicted by the CT scans of the 3D printed blocks. Conclusion: We have demonstrated that it is possible to 3D print materials of varying tissue equivalencies, and that these materials have radiological properties that are customizable and predictable.

60 APPLIED LIFE SCIENCES↗

Glycogen in the Nervous System: Methods for Light and Electron Microscopy - I

'l'he relative value of different methods for combined light and electron microscopical studies of glycogen in the nervous tissue was investigated. Picroalcoholic fixatives preserve glycogen in a considerable amount but give an inadequate morphological image of glycogen distribution and are unsuitable for ultrastructural studies. Fixation by perfusion, with Dalton's chromeosmic fluid seems adequate for ultrastructural cytochemistry of glycogen. Furthermore it permits routine paraffin embedding of brain slices adjacent to those used for electron microscopy. Dimedone blocking is a necessary step for a selective staining of glycogen with PAS after osmic fixation. Enzymatic removal of glycogen in osmic fixed nervous tissue can be done In paraffin-embedded tissue. It can also be performed in glycolmethacrylate-embedded tissue without removal of the embedding medium. Paraphenylenediamine stains glycogen following periodic acid oxidation.

Estable, Rosita F. De↗

Anatomy structure creation and editing using 3D implicit surfaces

Purpose: To accurately reconstruct, and interactively reshape 3D anatomy structures' surfaces using small numbers of 2D contours drawn in the most visually informative views of 3D imagery. The innovation of this program is that the number of 2D contours can be very much smaller than the number of transverse sections, even for anatomy structures spanning many sections. This program can edit 3D structures from prior segmentations, including those from autosegmentation programs. The reconstruction and surface editing works with any image modality. Methods: Structures are represented by variational implicit surfaces defined by weighted sums of radial basis functions (RBFs). Such surfaces are smooth, continuous, and closed and can be reconstructed with RBFs optimally located to efficiently capture shape in any combination of transverse (T), sagittal (S), and coronal (C) views. The accuracy of implicit surface reconstructions was measured by comparisons with the corresponding expert-contoured surfaces in 103 prostate cancer radiotherapy plans. Editing a pre-existing surface is done by overdrawing its profiles in image views spanning the affected part of the structure, deleting an appropriate set of prior RBFs, and merging the remainder with the new edit contour RBFs. Two methods were devised to identify RBFs to be deleted based only on the geometry of the initial surface and the locations of the new RBFs. Results: Expert-contoured surfaces were compared with implicit surfaces reconstructed from them over varying numbers and combinations of T/S/C planes. Studies revealed that surface-surface agreement increases monotonically with increasing RBF-sample density, and that the rate of increase declines over the same range. These trends were observed for all surface agreement metrics and for all the organs studied--prostate, bladder, and rectum. In addition, S and C contours may convey more shape information than T views for CT studies in which the axial slice thickness is greater than the pixel size. Surface editing accuracy likewise improves with larger sampling densities, and the rate of improvement similarly declines over the same conditions. Conclusions: Implicit surfaces based on RBFs are accurate representations of anatomic structures and can be interactively generated or modified to correct segmentation errors. The number of input contours is typically smaller than the number of T contours spanned by the structure.

62 RADIOLOGY AND NUCLEAR MEDICINE↗