Search NASA⌕ Search

SEARCH · Search NASA

Results for “squids”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

Large scale two-dimensional arrays of magnesium diboride superconducting quantum interference devices

Magnetic field sensors based on two-dimensional arrays of superconducting quantum interference devices were constructed from magnesium diboride thin films. Each array contained over 30 000 Josephson junctions fabricated by ion damage of 30 nm weak links through an implant mask defined by nano-lithography. Current-biased devices exhibited very large voltage modulation as a function of magnetic field, with amplitudes as high as 8 mV.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Storage and on-demand release of microwaves using superconducting resonators with tunable coupling

We present a system which allows to tune the coupling between a superconducting resonator and a transmission line. This storage resonator is addressed through a second, coupling resonator, which is frequency-tunable and controlled by a magnetic flux applied to a superconducting quantum interference device. We experimentally demonstrate that the lifetime of the storage resonator can be tuned by more than three orders of magnitude. A field can be stored for 18 μs when the coupling resonator is tuned off resonance and it can be released in 14 ns when the coupling resonator is tuned on resonance. The device allows capture, storage, and on-demand release of microwaves at a tunable rate.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Joint measurement of current-phase relations and transport properties of hybrid junctions using a three junctions superconducting quantum interference device

We propose a scheme to measure both the current-phase relation and differential conductance dI/dV of a superconducting junction, in the normal and the superconducting states. This is done using a dc Superconducting Quantum Interference Device with two Josephson junctions in parallel with the device under investigation and three contacts. As a demonstration, we measure the current-phase relation and dI/dV of a small Josephson junction and a carbon nanotube junction. In this latter case, in a regime where the nanotube is well conducting, we show that the non-sinusoidal current phase relation we find is consistent with the theory for a weak link, using the transmission extracted from the differential conductance in the normal state. This method holds great promise for future investigations of the current-phase relation of more exotic junctions.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Structural, optical, and magnetic properties of highly-resistive Sm-implanted GaN thin films

Samarium ions of 200 keV in energy were implanted into highly-resistive molecular-beam-epitaxy grown GaN thin films with a focused-ion-beam implanter at room temperature. The implantation doses range from 1 × 10{sup 14} to 1 × 10{sup 16 }cm{sup −2}. Structural properties studied by x-ray diffraction and Raman-scattering spectroscopy revealed Sm incorporation into GaN matrix without secondary phase. The optical measurements showed that the band gap and optical constants changed very slightly by the implantation. Photoluminescence measurements showed emission spectra similar to p-type GaN for all samples. Magnetic investigations with a superconducting quantum interference device identified magnetic ordering for Sm dose of and above 1 × 10{sup 15 }cm{sup −2} before thermal annealing, while ferromagnetism was only observed after thermal annealing from the sample with highest Sm dose. The long-range magnetic ordering can be attributed to interaction of Sm ions through the implantation-induced Ga vacancy.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Observation of the fundamental Nyquist noise limit in an ultra-high Q-factor cryogenic bulk acoustic wave cavity

Thermal Nyquist noise fluctuations of high-Q bulk acoustic wave cavities have been observed at cryogenic temperatures with a DC superconducting quantum interference device amplifier. High Q modes with bandwidths of few tens of milliHz produce thermal fluctuations with a signal-to-noise ratio of up to 23 dB. The estimated effective temperature from the Nyquist noise is in good agreement with the physical temperature of the device, confirming the validity of the equivalent circuit model and the non-existence of any excess resonator self-noise. The measurements also confirm that the quality factor remains extremely high (Q > 10{sup 8} at low order overtones) for very weak (thermal) system motion at low temperatures, when compared to values measured with relatively strong external excitation. This result represents an enabling step towards operating such a high-Q acoustic device at the standard quantum limit.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Note: Optical receiver system for 152-channel magnetoencephalography

An optical receiver system composing 13 serial data restore/synchronizer modules and a single module combiner converted optical 32-bit serial data into 32-bit synchronous parallel data for a computer to acquire 152-channel magnetoencephalography (MEG) signals. A serial data restore/synchronizer module identified 32-bit channel-voltage bits from 48-bit streaming serial data, and then consecutively reproduced 13 times of 32-bit serial data, acting in a synchronous clock. After selecting a single among 13 reproduced data in each module, a module combiner converted it into 32-bit parallel data, which were carried to 32-port digital input board in a computer. When the receiver system together with optical transmitters were applied to 152-channel superconducting quantum interference device sensors, this MEG system maintained a field noise level of 3 fT/√Hz @ 100 Hz at a sample rate of 1 kSample/s per channel.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effect of particle size distribution on the structure, hyperfine, and magnetic properties of Ni{sub 0.5}Zn{sub 0.5}Fe{sub 2}O{sub 4} nanopowders

Ni{sub 0.5}Zn{sub 0.5}Fe{sub 2}O{sub 4} nano powders were synthesized by an auto combustion method and then heat treated at different temperatures in air for a fixed time. As a consequence, a distribution in particle size and strain was incorporated within the specimens, as estimated from the Rietveld refinement analysis of the powder x-ray diffraction data. The changes in the microstructure and crystal structure parameters were carefully extracted through the refinement analysis. Thermal annealing causes increment in the dispersion and mean of the size distribution. Reallocation of cations in the lattice sites occur as a consequence of the heat treatment which was manifested in their altered unit cell length (a), r.m.s. strain (〈ε{sup 2}〉{sup 1/2}), oxygen positional parameter (u), metal-oxygen bond lengths (R{sub OA} and R{sub OB}), and the band positions (ν{sub 1}and ν{sub 2}) in the vibrational spectroscopy. We also investigate the hyperfine and magnetic properties of the samples using different instrumental techniques (with different operating time scales) like Mössbauer spectroscopy, electron paramagnetic resonance spectroscopy, and superconducting quantum interference device magnetometry. Results show that the effect of particle size distribution was manifested in their hyperfine field distribution profile, paramagnetic resonance spectra, and magnetic anisotropy energy distribution profile. Co-existence of superparamagnetic and ferrimagnetic phase was recorded at room temperature in the samples when annealed at lower temperature. However, with increase in annealing temperature, the nature of the size distribution changes and ferrimagnetic ordering predominates for the larger size nanoparticles. Thus, the effect of particle size distribution on the structural, hyperfine, and magnetic properties of various Ni{sub 0.5}Zn{sub 0.5}Fe{sub 2}O{sub 4} nanoparticles was investigated herein which hitherto has not been discussed in the literature.

36 MATERIALS SCIENCE↗

Magnetic particle detection in unshielded environment using orthogonal fluxgate gradiometer

A new detection system for magnetic particles, which can operate in an unshielded environment, is developed using a fundamental mode orthogonal fluxgate gradiometer. The proposed detection system offers the advantages of cost, size, and weight reduction as compared to contamination detection systems using superconducting quantum interference device sensor. The detection system can be used to detect metallic contamination in foods or lithium ion battery production lines. The system has been investigated numerically to optimize various design parameters of the system. Experimental setup has been developed to evaluate some of the numerically predicted results. Steel balls were successfully detected down to the diameter of 50 μm.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Purity analyses of high-purity organic compounds with nitroxyl radicals based on the Curie–Weiss law

This work reports an attempt to quantify the purities of powders of high-purity organic compounds with stable nitroxyl radicals (namely, 2,2,6,6-tetramethylpiperidine 1-oxyl (TEMPO), 1-oxyl-2,2,6,6-tetramethyl-4-hydroxypiperidine (TEMPOL), and 4-hydroxy-2,2,6,6-tetramethylpiperidine 1-oxyl benzoate (4-hydroxy-TEMPO benzoate)) in terms of mass fractions by using our “effective magnetic moment method,” which is based on both the Curie–Weiss law and a fundamental equation of electron paramagnetic resonance (ESR). The temperature dependence of the magnetic moment resulting from the radicals was measured with a superconducting quantum interference device magnetometer. The g value for each compound was measured with an X-band ESR spectrometer. The results of the purities were (0.998 ± 0.064) kg kg{sup −1} for TEMPO, (1.019 ± 0.040) kg kg{sup −1} for TEMPOL, and (1.001 ± 0.048) kg kg{sup −1} for 4-hydroxy-TEMPO benzoate. These results demonstrate that this analytical method as a future candidate of potential primary direct method can measure the purities with expanded uncertainties of approximately 5%.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Auditory evoked field measurement using magneto-impedance sensors

The magnetic field of the human brain is extremely weak, and it is mostly measured and monitored in the magnetoencephalography method using superconducting quantum interference devices. In this study, in order to measure the weak magnetic field of the brain, we constructed a Magneto-Impedance sensor (MI sensor) system that can cancel out the background noise without any magnetic shield. Based on our previous studies of brain wave measurements, we used two MI sensors in this system for monitoring both cerebral hemispheres. In this study, we recorded and compared the auditory evoked field signals of the subject, including the N100 (or N1) and the P300 (or P3) brain waves. The results suggest that the MI sensor can be applied to brain activity measurement.

60 APPLIED LIFE SCIENCES↗

Magnetic modification at sub-surface of FeRh bulk by energetic ion beam irradiation

Ferromagnetic layered structure has been made at sub-surface of the antiferromagnetic FeRh bulk samples by high energy He ion beam irradiation. In accordance with the Transport of Ions in Matter simulation, such ion beam can effectively deposit the elastic collision energy in several μm regions in the depth from the surface. Measurement with a superconducting quantum interference device reveals the irradiated samples to be ferromagnetic. Assuming that only the part the energy deposited can be modified to be ferromagnetic, the corresponding irradiation induced magnetization is consistent with the data that we previously reported. On the other hand, the X-ray magnetic circular dichroism (XMCD) spectra for the irradiated samples are totally unchanged as those for the unirradiated samples. Since XMCD signal in total emission yield method is considered to be surface sensitive with a typical probing depth of several nm, the surface magnetic state is maintained to be antiferromagnetic. By utilizing these phenomena, three-dimensional magnetic patterning of FeRh can be realized, which may potentially be used for future magnetic exchange device application such as nano-scale sensors and memories.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Magnetic resonance imaging without field cycling at less than earth's magnetic field

A strong pre-polarization field, usually tenths of a milli-tesla in magnitude, is used to increase the signal-to-noise ratio in ordinary superconducting quantum interference device-based nuclear magnetic resonance/magnetic resonance imaging experiments. Here, we introduce an experimental approach using two techniques to remove the need for the pre-polarization field. A dynamic nuclear polarization (DNP) technique enables us to measure an enhanced resonance signal. In combination with a π/2 pulse to avoid the Bloch-Siegert effect in a micro-tesla field, we obtained an enhanced magnetic resonance image by using DNP technique with a 34.5 μT static external magnetic field without field cycling. In this approach, the problems of eddy current and flux trapping in the superconducting pickup coil, both due to the strong pre-polarization field, become negligible.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Structural, morphological and magnetic study of (Bi{sub 0.1}Fe{sub 0.1}O{sub 3}) - (Ni{sub 0.1}Fe{sub 2(0.1)}O{sub 4}) nanocomposite

Multiferroic nanocomposite of (Bi{sub 0.1}Fe{sub 0.1}O{sub 3}) - (Ni{sub 0.1}Fe{sub 2(0.1)}O{sub 4}) was prepared by sol gel technique and characterized by X-ray diffraction, transmission electron microscopy, superconducting quantum interference device. X-ray diffraction confirmed the formation of desired crystallographic phase of the composite. The average particle size found to be 13.97nm. The transmission electron microscopy depicts the presence of the polycrystalline nanoparticles. In order to investigate the magnetic behavior superconducting quantum interference device was used. The sample was analyzed by increasing the magnetic field up to 25kOe and magnetization was found to be 16.8emu/g, which is optimum for the technological applications. The magnetic properties in such composite result as determined both by the ferrite concentration and properties and by the degree of connectivity of the two phases. The appropriate combination of two phases gives rise to higher magnetization.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

On the role of Fe ions on magnetic properties of doped TiO{sub 2} nanoparticles

The role of iron doping on magnetic properties of hydrothermal anatase TiO{sub 2}:{sup 57}Fe (0–1 at. %) nanoparticles is investigated by combining superconducting quantum interference device magnetometry with Mössbauer and electron paramagnetic resonance techniques. The results on both as-prepared and thermally treated samples in reduced air atmosphere reveal complexity of magnetic interactions, in connection to certain iron ion electron configurations and defects (oxygen vacancies, F-center, and Ti{sup 3+} ions). The distribution of iron ions is predominantly at nanoparticle surface layers. Formation of weak ferromagnetic domains up to 380 K is mainly related to defects, supporting the bound magnetic polaron model.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Fluorine-ion-beam modification of magnetic properties of thin GaMnAs films

Magnetic and electrical transport properties of fluorine-ion-beam irradiated GaMnAs films were studied as a function of ion fluence and energy of impinging ions. The different nature of defects created by ions of low- and high-energies is explored in this work by means of transport and magnetization measurements. Our results show that the saturation magnetization of the irradiated samples is suppressed as the ion fluence is increased. Interestingly, however, the same effect is not observed in the case of critical temperature, which remains nearly the same for irradiated and non-irradiated samples measured by superconducting quantum interference device. Magnetotransport measurements appear to provide more reliable results regarding the critical temperature, since they are consistent with the ion-irradiation-induced disorder in the GaMnAs film, quantified here as the increase of the resistivity. We discuss this behavior based on the inhomogeneity of damages caused by the irradiation process.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Characterization of the magnetic moment distribution in low-concentration solutions of iron oxide nanoparticles by a high-T{sub c} superconducting quantum interference device magnetometer

We developed a highly sensitive AC/DC magnetometer using a high-temperature superconductor superconducting quantum interference device for the evaluation of magnetic nanoparticles in solutions. Using the developed system, we investigated the distribution of magnetic moments of iron oxide multi-core particles of 100 nm at various iron concentrations that are lower than 96 μg/ml by analyzing the measured magnetization curves. Singular value decomposition and non-regularized non-negative least-squares methods were used during the reconstruction of the distribution. Similar distributions were obtained for all concentrations, and the iron concentration could be determined from the measured magnetization curves. The measured harmonics upon the excitation of AC and DC magnetic fields curves agreed well with the harmonics simulated based on the reconstructed magnetization curves, implying that the magnetization curves of magnetic nanoparticles were successfully obtained as we will show in the article. We compared the magnetization curves between multi-core particles of 100 nm and 130 nm, composed of 12-nm iron oxide nanoparticles. A distinctive magnetic property between the 100 nm and 130 nm particles in low-concentration solutions was successfully characterized. The distribution characteristic of magnetic moments suggests that the net magnetic moment in a multi-core particle is affected by the size of the magnetic cores and their degree of aggregation. Exploration of magnetic properties with high sensitivity can be expected using the developed system.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Hysteresis and change of transition temperature in thin films of Fe([Me{sub 2}Pyrz]{sub 3}BH){sub 2}, a new sublimable spin-crossover molecule

Thin films of the spin-crossover (SCO) molecule Fe([Me{sub 2}Pyrz]{sub 3}BH){sub 2} (Fe-pyrz) were sublimed on Si/SiO{sub 2} and quartz substrates, and their properties investigated by X-ray absorption and photoemission spectroscopies, optical absorption, atomic force microscopy, and superconducting quantum interference device. Contrary to the previously studied Fe(phen){sub 2}(NCS){sub 2}, the films are not smooth but granular. The thin films qualitatively retain the typical SCO properties of the powder sample (SCO, thermal hysteresis, soft X-ray induced excited spin-state trapping, and light induced excited spin-state trapping) but present intriguing variations even in micrometer-thick films: the transition temperature decreases when the thickness is decreased, and the hysteresis is affected. We explain this behavior in the light of recent studies focusing on the role of surface energy in the thermodynamics of the spin transition in nano-structures. In the high-spin state at room temperature, the films have a large optical gap (∼5 eV), decreasing at thickness below 50 nm, possibly due to film morphology.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗