Search NASA⌕ Search

SEARCH · Search NASA

Results for “static testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

Wind-tunnel Tests of Four Curtiss Propellers Embodying Different Blade Sections

Tests of four 10-foot propellers were made in the propeller-research tunnel for the Army Air Corps to check flight and static thrust test results made on several propellers embodying Clark Y and modified NACA 16-series sections. These propellers were identical as to diameter and activity factor and very closely identical in thickness ratio and pitch distribution. The blades embodied sections with both single- and double-cambered Clark Y, modified NACA 16-series, and a combination of Clark Y and modified NACA-16 airfoils. Tests covered a range of blade angles from 20 deg. to 70 deg., and were all made at tip speeds below 280 feet per second. Although these tests were not conclusive in themselves, owing to the conditions under which they were made, the results seem to check the flight and static tests as closely as would be expected.

AIRFOILS - CLARK Y - CHARACTERISTICS PROPELLER↗

Integration Time Required to Extract Accurate Data from Transonic Wind-Tunnel Tests

Because the forces and pressures on wind-tunnel models tested at transonic speeds are not steady, even for static aerodynamic tests, integration time is required to obtain data of acceptable accuracy. The integration time required for both static and dynamic tests is evaluated analytically and confirmed by experimental measurements. It is shown that, for static and dynamic tests, the accuracy obtained is a function of integration time, frequency of the signal, and the ratio of the dynamic amplitude to the full signal of interest. In addition, for the dynamic case, the frequency bandwidth used in analysis is important. Results of this study indicate that, for typical data accuracy desired from models in a large transonic wind tunnel (11- by 11-ft), up to the following integration times are required: static force and moment tests, 0.5 s; static pressure tests, 1 s; flutter tests, 30 to 60 s; and random-dynamic tests, 10 s.

Muhlstein, Lado, Jr.↗

Ground-based Design of a Test System to Evaluate Static Vapor Feed Electrolysis for Oxygen Generation

NASA designed a test facility to evaluate the performance of a Static Vapor Feed Electrolysis (SVFE) cell stack to determine its viability as an alternative technology to the state-of-the-art Oxygen Generation Assembly (OGA) to generate oxygen for habitable spacecraft environments. Static Vapor Feed Electrolysis differs from the liquid cathode-feed process utilized by the OGA in that the electrolysis process occurs entirely in the gas phase, operates at a higher pressure than OGA, and potentially requires a simpler balance-of-plant system. Pressurized liquid water is statically-fed, i.e. dead-headed, through a vapor-permeable membrane into the electrolysis chamber of the cell stack. The water vapor is then electrolyzed into hydrogen and oxygen in the cathode and anode chambers, respectively, all the while maintaining above-ambient pressures to eliminate water condensation in the oxygen and hydrogen product streams. This paper presents the design of the test facility and accompanying required balance-of-plant that will be used to test the SVFE cell stack.

Zeeshan Khawar↗

Static and Wind Tunnel Aero-Performance Tests of NASA AST Separate Flow Nozzle Noise Reduction Configurations

This report presents the results of cold flow model tests to determine the static and wind tunnel performance of several NASA AST separate flow nozzle noise reduction configurations. The tests were conducted by Aero Systems Engineering, Inc., for NASA Glenn Research Center. The tests were performed in the Channels 14 and 6 static thrust stands and the Channel 10 transonic wind tunnel at the FluiDyne Aerodynamics Laboratory in Plymouth, Minnesota. Facility checkout tests were made using standard ASME long-radius metering nozzles. These tests demonstrated facility data accuracy at flow conditions similar to the model tests. Channel 14 static tests reported here consisted of 21 ASME nozzle facility checkout tests and 57 static model performance tests (including 22 at no charge). Fan nozzle pressure ratio varied from 1.4 to 2.0, and fan to core total pressure ratio varied from 1.0 to 1.19. Core to fan total temperature ratio was 1.0. Channel 10 wind tunnel tests consisted of 15 tests at Mach number 0.28 and 31 tests at Mach 0.8. The sting was checked out statically in Channel 6 before the wind tunnel tests. In the Channel 6 facility, 12 ASME nozzle data points were taken and 7 model data points were taken. In the wind tunnel, fan nozzle pressure ratio varied from 1.73 to 2.8, and fan to core total pressure ratio varied from 1.0 to 1.19. Core to fan total temperature ratio was 1.0. Test results include thrust coefficients, thrust vector angle, core and fan nozzle discharge coefficients, total pressure and temperature charging station profiles, and boat-tail static pressure distributions in the wind tunnel.

Mikkelsen, Kevin L.↗

Mechanical Characterization of Fe-Co-2V (Hiperco): Fatigue/Monotonic Testing Hardness Testing and Fractography

Fe-Co-2V is a popular metallic alloy used in electromagnetic applications. However, there is a lack of mechanical fatigue characterization of this alloy in the literature. In this work, Fe-Co-2V specimens with rectangular cross-sections were carefully prepared in accordance with standards. They were measured for surface roughness and then subjected to quasi-static monotonic testing, as well as fatigue testing at both 0.5 Hz and 1 Hz frequencies. Both Rockwell hardness and Vickers micro- hardness testing were performed. Additionally, scanning electron microscopy imaging of the fractured surfaces was done. The quasi-static testing revealed a flat yield region characteristic of Laders bands. Here, the fatigue results did not show significant differences or sensitivity to change in frequency, although the fatigue life was higher on average for the 0.5 Hz. However, the fatigue results differed from published work at 0.33 Hz. The fractography revealed purely brittle fracture, with clear chevron marks and fracture initiation always starting at the surface. Lastly, it was identified that the C, D, and F Rockwell hardness scales were appropriate for testing this material and that the grain size necessitated the use of the upper end of indentation force for Vickers micro-hardness testing.

36 MATERIALS SCIENCE↗

Dynamic stability and handling qualities tests on a highly augmented, statically unstable airplane

Novel flight test and analysis techniques in the flight dynamics and handling qualities area are described. These techniques were utilized at NASA Ames-Dryden during the initial flight envelope clearance of the X-29A aircraft. It is shown that the open-loop frequency response of an aircraft with highly relaxed static stability can be successfully computed on the ground from telemetry data. Postflight closed-loop frequency response data were obtained from pilot-generated frequency sweeps and it is found that the current handling quality requirements for high-maneuverability aircraft are generally applicable to the X-29A.

Gera, Joseph↗

Criteria for initiation of delamination in quasi-static punch-shear tests of a carbon-fiber composite material.

V arious phenomenological delamination initiation criteria are analyzed in quasi - static punch - shear tests conducted on six different geometries. These six geometries are modeled and analyzed using elastic, large - deformation finite element analysis. Analysis output is post - processed to assess different delamination initiation criteria, and their applicability to each of the geometries. These criteria are compared to test results to assess whether or not they are appropriate based on what occurred in testing. Further, examinations of CT scans and ultrasonic images o f test specimens are conducted in the appendix to determine the sequence of failure in each test geometry.

Chin, Eric Brian↗

An innovative technique for static and dynamic V/STOL testing

Initial hover testing of the Navy's XFV-12A V/STOL technology prototype aircraft is being conducted in the former Lunar Lander Research Facility at the NASA Langley Research Center. The aircraft incorporates a unique lift/control concept for V/STOL flight. A key element in the development of this aircraft has been the application of existing hardware and facilities to conserve program funds. Adaptation of the NASA Gantry has created a V/STOL aircraft test facility with unique capability and flexibility. Static lift and control measurements can be obtained and dynamic hover flight can be conducted over a wide range of realistic test conditions.

Lewis, E. L.↗

Aerodynamic and Acoustic Performance of Two Choked-Flow Inlets Under Static Conditions

Tests were conducted to determine the aerodynamic and acoustic performance of two choking flow inlets under static conditions. One inlet choked the flow in the cowl throat by an axial translation of the inlet centerbody. The other inlet employed a translating grid of airfoils to choke the flow. Both inlets were sized to fit a 13.97 cm diameter fan with a design weight flow of 2.49 kg/sec. The inlets were operated in both the choked and unchoked modes over a range of weight flows. Measurements were made of inlet pressure recovery, flow distortion, surface static pressure distribution, and fan noise suppression. Choking of the translating centerbody inlet reduced blade passing frequency noise by 29 db while yielding a total pressure recovery of 0.985. Noise reductions were also measured at 1/3-octave band center frequencies of 2500, 5000, and 20,000 cycles. The translating grid inlet gave a total pressure recovery of 0.968 when operating close to the choking weight flow. However, an intermittent high intensity noise source was encountered with this inlet that precluded an accurate measurement of inlet noise suppression.

Miller, B. A.↗

Static tensile and tensile creep testing of four boron nitride coated ceramic fibers at elevated temperatures

Six types of uncoated ceramic fibers were static tensile and tensile creep tested at various elevated temperatures. Three types of boron nitride coated fibers were also tested. Room temperature static tensile tests were initially performed on all fibers, at gage lengths of 1, 2, and 4 inches, to determine the magnitude of end effects from the gripping system used. Tests at one elevated temperature, at gage lengths of 8 and 10 inches, were also conducted, to determine end effects at elevated temperatures. Fiber cross sectional shapes and areas were determined using scanning electron microscopy. Creep testing was typically performed for 4 hours, in an air atmosphere.

Coguill, Scott L.↗

Solid propellant exhausted aluminum oxide and hydrogen chloride - Environmental considerations

Measurements of gaseous hydrogen chloride (HCl) and particulate aluminum oxide (Al2O3) were made during penetrations of five Space Shuttle exhaust clouds and one static ground test firing of a shuttle booster. Instrumented aircraft were used to penetrate exhaust clouds and to measure and/or collect samples of exhaust for subsequent analyses. The focus was on the primary solid rocket motor exhaust products, HCl and Al2O3, from the Space Shuttle's solid boosters. Time-dependent behavior of HCl was determined for the exhaust clouds. Composition, morphology, surface chemistry, and particle size distributions were determined for the exhausted Al2O3. Results determined for the exhaust cloud from the static test firing were complicated by having large amounts of entrained alkaline ground debris (soil) in the lofted cloud. The entrained debris may have contributed to neutralization of in-cloud HCl.

Cofer, W. R., III↗

C-130: Results of center wing residual strength and crack propagation test program

Fourteen C-130 airplane center wings which had experienced from approximately 4,000 to 13,000 hours of flight service and its associated fatigue damage were tested to destruction, seven in upbending and seven in downbending. Six wings were tested directly for static residual strength in the fatigue-damaged condition as received from field service. The other eight wings were tested in crack propagation cyclic testing at a prescribed stress level for a maximum of 10,000 cycles. Then the stress level was reduced and testing was continued up to a maximum of 20,000 total cycles. Cyclic testing was performed with constant-amplitude stresses at a stress ratio of +0.1. Maximum cyclic skin stresses were approximately 18,000 psi. At the conclusion of cyclic testing, a static test to destruction was conducted to determine the residual strength of each fatigue-damaged specimen.

Reeder, F. L.↗

Towards Polymer-Free, Femto-Second Laser-Welded Glass/Glass Solar Modules

This project explores the use of femto-second (fs) lasers to form glass-to-glass welds for hermetically sealed, polymer-free solar modules. Low iron solar glass coupons were welded together without the use of glass filler using a fs laser with dedicated optics to elongate the focal plane parallel to the incident beam. The resulting welds were then stress tested to failure to reveal the critical stress intensity factor, KIc. These values were used in a structural mechanics model of a 1 m by 2 m glass/glass module under a simulated static load test. The results show that the fs laser welds are strong enough for a suitably framed module to pass the IEC 61215 static load test with a load of 5400 Pa. Key to this finding is that the module must be framed and braced, and the glass must be ribbed to allow pockets for the cells and welds inside the border of the module. The result is a module design that is completely polymer-free, hermetically sealed, has improved thermal properties, and is easily recycled.

femto-second laser welded↗

Testing techniques for determining static mechanical properties of Pneumatic tires

Fore-aft, lateral, and vertical spring rates of model and full-scale pneumatic tires were evaluated by testing techniques generally employed by industry and various testing groups. The purpose of this experimental program was to investigate what effects the different testing techniques have on the measured values of these important static tire mechanical properties. The testing techniques included both incremental and continuous loadings applied at various rates over half, full, and repeated cycles. Of the three properties evaluated, the fore-aft stiffness was demonstrated to be the most affected by the different testing techniques used to obtain it. Appreciable differences in the fore-aft spring rates occurred using both the increment- and continuous-loading techniques; however, the most significant effect was attributed to variations in the size of the fore-aft force loop. The dependence of lateral stiffness values on testing techniques followed the same trends as that for fore-aft stiffness, except to a lesser degree. Vertical stiffness values were found to be nearly independent of testing procedures if the nonlinear portion of the vertical force-deflection curves is avoided.

Dodge, R. N.↗

The Langley thermal protection system test facility: A description including design operating boundaries

A description of the Langley thermal protection system test facility is presented. This facility was designed to provide realistic environments and times for testing thermal protection systems proposed for use on high speed vehicles such as the space shuttle. Products from the combustion of methane-air-oxygen mixtures, having a maximum total enthalpy of 10.3 MJ/kg, are used as a test medium. Test panels with maximum dimensions of 61 cm x 91.4 cm are mounted in the side wall of the test region. Static pressures in the test region can range from .005 to .1 atm and calculated equilibrium temperatures of test panels range from 700 K to 1700 K. Test times can be as long as 1800 sec. Some experimental data obtained while using combustion products of methane-air mixtures are compared with theory, and calibration of the facility is being continued to verify calculated values of parameters which are within the design operating boundaries.

Klich, G. F.↗

Analysis and documentation of QCSEE (Quiet Clean Short-haul Experimental Engine) over-the-wing exhaust system development

A static scale model test program was conducted in the static test area of the NASA-Langley 9.14- by 18.29 m(30- by 60-ft) Full-Scale Wind Tunnel Facility to develop an over-the-wing (OTW) nozzle and reverser configuration for the Quiet Clean Short-Haul Experimental Engine (QCSEE). Three nozzles and one basic reverser configuration were tested over the QCSEE takeoff and approach power nozzle pressure ratio range between 1.1 and 1.3. The models were scaled to 8.53% of QCSEE engine size and tested behind two 13.97-cm (5.5-in.) diameter tip-turbine-driven fan simulators coupled in tandem. An OTW nozzle and reverser configuration was identified which satisfies the QCSEE experimental engine requirements in terms of nozzle cycle area variation capability and reverse thrust level, and provides good jet flow spreading over a wing upper surface for achievement of high propulsive lift performance.

Ammer, R. C.↗

The XFV-12A Thrust-Augmented Wing (TAW) prototype aircraft

The XFV-12A, a unique V/STOL technology prototype aircraft being developed for the Navy, is described. The innovative design features a thrust augmented wing and a canard ejector. Structural, functional, and control test performances are discussed. Static tether test results are also discussed. Assessment of test results are given along with projections for future modification areas.

Murphy, R.↗

Straight cylindrical seal for high-performance turbomachines

A straight cylindrical seal configuration representing the seal for a high-performance turbopump (e.g., the space shuttle main engine fuel pump) was tested under static (nonrotating) conditions. The test data included critical mass flux and pressure profiles over a wide range of inlet temperatures and pressures for fluid nitrogen and fluid hydrogen with the seal in concentric and fully eccentric positions. The critical mass fluxes (or leakage rates) for the concentric and fully eccentric configurations were nearly the same when based on stagnation conditions upstream of the seal. The fully eccentric configuration pressure profiles of the gas and liquid were different. Further, the pressure differences between the maximum and the minimum clearance positions were highly dependent on the geometric conditions, the temperature, and the absolute pressure at both the inlet and the exit. The pressure differences were greatest in the inlet region. The results, although complex, tend to follow the corresponding-states principles for critical flows. Gaseous injection near the seal exit plane significantly altered the pressure profiles and could be used to control turbomachine instabilities.

Hendricks, Robert C.↗