Search NASA⌕ Search

SEARCH · Search NASA

Results for “study”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

In Situ X-ray Absorption and Diffraction Studies of Carbon Coated LiFe1/4Mn1/4Co1/4Ni1/4PO4 Cathode During First Charge

Synchrotron based in situ X-ray absorption spectroscopy (XAS) and X-ray diffraction (XRD) techniques are used to study electronic and crystal structure changes of the carbon coated LiFe1/4Mn1/4Co1/4Ni1/4PO4 (LiFe1/4Mn1/4Co1/4Ni1/4PO4/C) cathode material for Li-ion batteries during the first charge. In situ Fe, Mn, Co and Ni K-edge XAS results revealed that the three voltage plateaus at 3.6, 4.2 and 4.7 V vs. Li/Li+ are attributed to the redox reactions of Fe2+/Fe3+, Mn2+/Mn3+ and Co2+/Co3+, respectively, while the apparent capacities above 4.9 V is not originated from the Ni2+/Ni3+ redox, but very likely from the electrolyte decomposition. Interesting phase transition behaviors of LiFe1/4Mn1/4Co1/4Ni1/4PO4/C wereobserved with the formation of an intermediate phase and the solid solution regions. Combined in situ XAS and XRD techniques indicate fast electronic structural changes and slow bulk crystal structural changes.

36 MATERIALS SCIENCE↗

Experimental study on the effect of nozzle hole-to-hole angle on the near-field spray of diesel injector using fast X-ray phase-contrast imaging

Fuel atomization and vaporization process play a critical role in determining the engine combustion and emission. The primary near-nozzle breakup is the vital link between the fuel emerging from the nozzle and the fully atomized spray. In this study, the near-nozzle spray characteristics of diesel injector with different umbrella angle (UA) were investigated using high-speed X-ray phase-contrast imaging and quantitative image processing. A classic ‘dumbbell’ profile of spray width (SW) composed of three stages: opening stage, semisteady stage and closing stage. The SW peak of two-hole injectors was more than twice of that of single-hole injector at the opening and closing stages, corresponding to the hollow-cone spray. This indicated the vortex flow was formed with the increase of the UA. The higher injection pressure had little influence on the SW while led to earlier breakup closer to the nozzle. Significant fuel effect on the SW at higher needle lift was found. However, this effect could be neglect at lower needle lift due to the leading role of internal flow and cavitation on the near-field spray characteristics. In addition, the morphology-based breakup process was observed, which highlighted the important effect of internal flow on the spray development. The possibility of using hollow-cone spray in diesel injector was also discussed.

biodiesel↗

Conceptual magnet design study for fusion nuclear science facility [Magnet design study for fusion nuclear science facility]

The Fusion Nuclear Science Facility (FNSF) is a nuclear confinement device to provide the integrated fusion environment with fusion reactor components. The FNSF is the stepping stone to bridge the technical gaps of burning plasma and nuclear science between the International Thermal Nuclear Experimental Reactor (ITER), currently under construction in the south of France, and the demonstration power plant (DEMO). For the next-step fusion reactors, resistive copper magnet cannot be a sustainable solution due to large power consumption in coils of large size needed. Both Low temperature superconductor (LTS) and high temperature superconductor (HTS) are considered for the FNSF magnet design based on the state-of-the-art fusion superconducting magnet technology. Input parameters to FNSF magnet design include magnetic field of 7.5 T at plasma center with a major radius of 4.8 m and minor radius of 1.2 m, and a peak field of over 16 T on the TF coils. The high magnetic field can be achieved by using the high performance ternary Restack Rod Process (RRP) Nb3Sn strands for toroidal field (TF) magnets and a high aspect ratio rectangular cable-in-conduit conductor (CICC) design. The conductor design concept and TF coil winding pack composition and dimension are discussed based on the horizontal maintenance scheme. Neutron radiation limits for the LTS and HTS conductors and electrical insulation materials are reviewed based on the available materials previously tested. The material radiation limits for FNSF magnets are defined as part of the conceptual design studies. In conclusion, the global structural analysis of FNSF magnets based on the radial build was performed to validate feasibility for the plant layout toward horizontal maintenance and global structural integrity of its magnet system.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The North Dakota integrated carbon storage complex feasibility study

Here, the Energy & Environmental Research Center is investigating the feasibility of safely, permanently, and economically storing 50 million tonnes of CO 2 in central North Dakota, United States, over a 25-year operational period, should a business case for CO 2 storage emerge. The study is part of the U.S. Department of Energy (DOE) National Energy Technology Laboratory CarbonSAFE initiative and addresses the technical and nontechnical challenges of commercially deploying a CO 2 storage project. Evaluation of cores from two stratigraphic test wells demonstrate that the Broom Creek Formation (sandstone) is an excellent candidate for the geologic storage of CO 2 and the overlying Opeche Formation a competent cap rock.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Insufficiency Fractures After Pelvic Radiation Therapy for Uterine Cervical Cancer: An Analysis of Subjects in a Prospective Multi-institutional Trial, and Cooperative Study of the Japan Radiation Oncology Group (JAROG) and Japanese Radiation Oncology Study Group (JROSG)

Purpose: To investigate pelvic insufficiency fractures (IF) after definitive pelvic radiation therapy for early-stage uterine cervical cancer, by analyzing subjects of a prospective, multi-institutional study. Materials and Methods: Between September 2004 and July 2007, 59 eligible patients were analyzed. The median age was 73 years (range, 37-84 years). The International Federation of Gynecologic Oncology and Obstetrics stages were Ib1 in 35, IIa in 12, and IIb in 12 patients. Patients were treated with the constant method, which consisted of whole-pelvic external-beam radiation therapy of 50 Gy/25 fractions and high-dose-rate intracavitary brachytherapy of 24 Gy/4 fractions without chemotherapy. After radiation therapy the patients were evaluated by both pelvic CT and pelvic MRI at 3, 6, 12, 18, and 24 months. Diagnosis of IF was made when the patients had both CT and MRI findings, neither recurrent tumor lesions nor traumatic histories. The CT findings of IF were defined as fracture lines or sclerotic linear changes in the bones, and MRI findings of IF were defined as signal intensity changes in the bones, both on T1- and T2-weighted images. Results: The median follow-up was 24 months. The 2-year pelvic IF cumulative occurrence rate was 36.9% (21 patients). Using Common Terminology Criteria for Adverse Events version 3.0, grade 1, 2, and 3 IF were seen in 12 (21%), 6 (10%), and 3 patients (5%), respectively. Sixteen patients had multiple fractures, so IF were identified at 44 sites. The pelvic IF were frequently seen at the sacroileal joints (32 sites, 72%). Nine patients complained of pain. All patients' pains were palliated by rest or non-narcotic analgesic drugs. Higher age (>70 years) and low body weight (<50 kg) were thought to be risk factors for pelvic IF (P=.007 and P=.013, Cox hazard test). Conclusions: Cervical cancer patients with higher age and low body weight may be at some risk for the development of pelvic IF after pelvic radiation therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗