Search NASA⌕ Search

SEARCH · Search NASA

Results for “techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

Novel Technique for Hepatic Fiducial Marker Placement for Stereotactic Body Radiation Therapy

Purpose: To report experience with fiducial marker insertion and describe an advantageous, novel technique for fiducial placement in the liver for stereotactic body radiation therapy with respiratory tracking. Methods and Materials: We implanted 1444 fiducials (single: 834; linked: 610) in 328 patients with 424 hepatic lesions. Two methods of implantation were compared: the standard method (631 single fiducials) performed on 153 patients from May 2007 to May 2010, and the cube method (813 fiducials: 610 linked/203 single) applied to 175 patients from April 2010 to March 2013. The standard method involved implanting a single marker at a time. The novel technique entailed implanting 2 pairs of linked markers when possible in a way to occupy the perpendicular edges of a cube containing the tumor inside. Results: Mean duration of the cube method was shorter than the standard method (46 vs 61 minutes; P<.0001). Median numbers of skin and subcapsular entries were significantly smaller with the cube method (2 vs 4, P<.0001, and 2 vs 4, P<.0001, respectively). The rate of overall complications (total, major, and minor) was significantly lower in the cube method group compared with the standard method group (5.7% vs 13.7%; P=.013). Major complications occurred while using single markers only. The success rate was 98.9% for the cube method and 99.3% for the standard method. Conclusions: We propose a new technique of hepatic fiducial implantation that makes use of linked fiducials and involves fewer skin entries and shorter time of implantation. The technique is less complication-prone and is migration-resistant.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Opportunities for plasma separation techniques in rare earth elements recycling

Rare earth elements recycling has been proposed to alleviate supply risks and market volatility. In this context, the potential of a new recycling pathway, namely plasma mass separation, is uncovered through the example of nedodymium - iron - boron magnets recycling. Plasma mass separation is shown to address some of the shortcomings of existing rare earth elements recycling pathways, in particular detrimental environmental effects. Here, a simplifed mass separation model suggests that plasma separation performances could compare favourably with existing recycling options. In addition, simple energetic considerations of plasma processing suggest that the cost of these techniques may not be prohibitive, particularly considering that energy costs from solar may become significantly cheaper. Further investigation and experimental demonstration of plasma separation techniques should permit asserting the potential of these techniques against other recycling techniques currently under development.

Economic feasibility↗

Grid and basis adaptive polynomial chaos techniques for sensitivity and uncertainty analysis

The demand for accurate and computationally affordable sensitivity and uncertainty techniques is constantly on the rise and has become especially pressing in the nuclear field with the shift to Best Estimate Plus Uncertainty methodologies in the licensing of nuclear installations. Besides traditional, already well developed methods – such as first order perturbation theory or Monte Carlo sampling – Polynomial Chaos Expansion (PCE) has been given a growing emphasis in recent years due to its simple application and good performance. This paper presents new developments of the research done at TU Delft on such Polynomial Chaos (PC) techniques. Our work is focused on the Non-Intrusive Spectral Projection (NISP) approach and adaptive methods for building the PCE of responses of interest. Recent efforts resulted in a new adaptive sparse grid algorithm designed for estimating the PC coefficients. The algorithm is based on Gerstner's procedure for calculating multi-dimensional integrals but proves to be computationally significantly cheaper, while at the same it retains a similar accuracy as the original method. More importantly the issue of basis adaptivity has been investigated and two techniques have been implemented for constructing the sparse PCE of quantities of interest. Not using the traditional full PC basis set leads to further reduction in computational time since the high order grids necessary for accurately estimating the near zero expansion coefficients of polynomial basis vectors not needed in the PCE can be excluded from the calculation. Moreover the sparse PC representation of the response is easier to handle when used for sensitivity analysis or uncertainty propagation due to the smaller number of basis vectors. The developed grid and basis adaptive methods have been implemented in Matlab as the Fully Adaptive Non-Intrusive Spectral Projection (FANISP) algorithm and were tested on four analytical problems. These show consistent good performance both in terms of the accuracy of the resulting PC representation of quantities and the computational costs associated with constructing the sparse PCE. Basis adaptivity also seems to make the employment of PC techniques possible for problems with a higher number of input parameters (15–20), alleviating a well known limitation of the traditional approach. The prospect of larger scale applicability and the simplicity of implementation makes such adaptive PC algorithms particularly appealing for the sensitivity and uncertainty analysis of complex systems and legacy codes.

97 MATHEMATICS AND COMPUTING↗

X-ray characterization technique for the assessment of surface damage in GaN wafers

SixPoint Materials has successfully switched to production of two-inch diameter GaN wafers using the ammonothermal method. Crystal quality values are high with dislocation densities typically in the low 10 5 cm -2 . In efforts to produce true epi-ready material, investigations were made to develop a technique to study surface damage caused by the back-end process using X-ray diffraction methods. Analysis of peak tailing from X-ray rocking curves of the (1 1 4) reflection indicates the progression of surface damage during each step of the back-end process. For instance, the tailing can be partially represented using full width five thousand max (FW5000M) values. By using a peak with a low glancing angle, such as the (1 1 4) reflection’s angle of 10.8662°, more of the X-ray beam is scattered in the surface region, providing an improved measurement of surface damage. Since this technique is non-destructive and can be performed without dismounting the sample from its ceramic back-end processing plate, it can provide information on the damaged layer at each stage of the back-end process. Using this technique to evaluate samples from various manufacturers, we found a lack of uniformity in surface damage from GaN companies. It is our hope that this technique will be adopted to better standardize surface damage measurements in the GaN field.

36 MATERIALS SCIENCE↗

Growth interface study of CdTeSe crystals grown by the THM technique

The Traveling Heater Method (THM) is a widely accepted technique to grow high-quality detector grade CdTe and CdZnTe ingots, especially for X-ray and gamma-ray detector applications. Unlike melt-growth techniques, the growth interface for ingots produced by the THM technique consists of two different compounds, viz. the solidified region (just below the interface) consists of the compound to be grown (e.g., CdZnTe for CdZnTe growth), while the molten zone just above the growth interface consists of Te-rich CdZnTe. Thus, optimization of the growth parameters is critical to obtain a clean growth interface with the required shape and presence of minimal Te-rich inclusions. Here, in this study, CdTeSe ingots were grown employing the THM technique to investigate the growth interface. Both macroscopic and microscopic behavior of the interface were studied. The study revealed that a microscopically smooth growth interface can be achieved by optimizing the growth parameters, which is essential for obtaining high-quality, inclusion-free ingots.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Reactive impinging-flow technique for polymer-electrolyte-fuel-cell electrode-defect detection

Reactive impinging flow (RIF) is a novel quality-control method for defect detection (i.e., reduction in Pt catalyst loading) in gas-diffusion electrodes (GDEs) on weblines. The technique uses infrared thermography to detect temperature of a nonflammable (<4% H 2 ) reactive mixture of H 2 /O 2 in N 2 impinging and reacting on a Pt catalytic surface. In this article, different GDE size defects (with catalyst-loading reductions of 25, 50, and 100%) are detected at various webline speeds (3.048 and 9.144 m min -1 ) and gas flowrates (32.5 or 50 standard L min -1 ). Furthermore, a model is developed and validated for the technique, and it is subsequently used to optimize operating conditions and explore the applicability of the technique to a range of defects. The model suggests that increased detection can be achieved by recting more of the impinging H 2 , which can be accomplished by placing blocking substrates on the top, bottom, or both of the GDE; placing a substrate on both results in a factor of four increase in the temperature differential, which is needed for smaller defect detection. Lastly, overall, the RIF technique is shown to be a promising route for in-line, high-speed, large-area detection of GDE defects on moving weblines.

30 DIRECT ENERGY CONVERSION↗

Use of time history speckle pattern and pulsed photoacoustic techniques to detect the self-accommodating transformation in a Cu-Al-Ni shape memory alloy

Continuous and pulsed electromagnetic radiation was used to detect the self-accommodation mechanism on a polycrystalline Cu-13.83 wt.%Al-2.34 wt.%Ni shape memory alloy. Rectangular samples of this alloy were mechanically polished to observe the austenite and martensite phases. The samples were cooled in liquid nitrogen prior to the experiments to obtain the martensite phase. Using a dynamic speckle technique with a continuous wave laser we obtained the time history of the speckle pattern image and monitored the surface changes caused by the self-accommodation mechanism during the inverse (martensitic to austenitic) transformation. Using a photoacoustic technique based on a pulsed laser source it was also possible to detect the self-accommodation phenomena in a bulk sample. For comparison purposes, we used differential scanning calorimetry (DSC) to detect the critical temperatures of transformation and use these as reference to evaluate the performance of the optical and photoacoustical techniques. In all cases, the same range of temperature was obtained during the inverse transformation. From these results, we conclude that time history speckle pattern (THSP) and pulsed photoacoustic are complementary techniques; they are non-destructive and useful to detect surface and bulk martensitic transformation induced by a temperature change.

36 MATERIALS SCIENCE↗

A Novel Method of Island Blocking in Whole Abdominal Radiotherapy Using a Modified Electronic Tissue Compensation Technique

Traditionally, large fields requiring island blocking used external beam radiation therapy (EBRT) with Cerrobend blocks to limit dose to the critical structures. It is laborious to construct blocks and use them on a daily basis. We present a novel technique for island blocking using a modified electronic tissue compensation (MECOMP) technique. Five patients treated at our institution were selected for this study. The study compared two planning techniques: a novel MECOMP and a conventional EBRT technique. Conventional fields were defined using anterior-posterior and posterior-anterior (PA) fields. The kidneys were contoured and an aperture cut-out block was fitted to the OAR with a 1-cm margin (OAR{sub CTV}) and placed in the PA field. A dynamic multileaf collimation (DMLC) plan with ECOMP was developed using identical beam and blocking strategy; this tissue compensation-based fluence map was modified to deliver a 'zero' dose to the CTV{sub OAR} from the PA field. There were no significant differences in the mean, maximum, and minimum doses to the right or left kidney between the two methods. The mean, maximum, and minimum doses to the peritoneal cavity were also not significantly different. The number of monitor units (MUs) required was increased using the MECOMP (273 vs. 1152, p < 0.01). The MECOMP is effectively able to deliver DMLC-based radiotherapy, even with island blocks present. This novel use of MECOMP for whole abdominal radiotherapy should substantially reduce the labor, daily treatment time, and treatment-related errors through the elimination of cerrobend blocks.

61 RADIATION PROTECTION AND DOSIMETRY↗

Bowel sparing in pediatric cranio-spinal radiotherapy: a comparison of combined electron and photon and helical TomoTherapy techniques to a standard photon method

The aim of this study was to compare the dose to organs at risk (OARs) from different craniospinal radiotherapy treatment approaches available at the Northern Centre for Cancer Care (NCCC), with a particular emphasis on sparing the bowel. Method: Treatment plans were produced for a pediatric medulloblastoma patient with inflammatory bowel disease using 3D conformal 6-MV photons (3DCP), combined 3D 6-MV photons and 18-MeV electrons (3DPE), and helical photon TomoTherapy (HT). The 3DPE plan was a modification of the standard 3DCP technique, using electrons to treat the spine inferior to the level of the diaphragm. The plans were compared in terms of the dose-volume data to OARs and the nontumor integral dose. Results: The 3DPE plan was found to give the lowest dose to the bowel and the lowest nontumor integral dose of the 3 techniques. However, the coverage of the spine planning target volume (PTV) was least homogeneous using this technique, with only 74.6% of the PTV covered by 95% of the prescribed dose. HT was able to achieve the best coverage of the PTVs (99.0% of the whole-brain PTV and 93.1% of the spine PTV received 95% of the prescribed dose), but delivered a significantly higher integral dose. HT was able to spare the heart, thyroid, and eyes better than the linac-based techniques, but other OARs received a higher dose. Conclusions: Use of electrons was the best method for reducing the dose to the bowel and the integral dose, at the expense of compromised spine PTV coverage. For some patients, HT may be a viable method of improving dose homogeneity and reducing selected OAR doses.

61 RADIATION PROTECTION AND DOSIMETRY↗

Implementation and evaluation of modified dynamic conformal arc (MDCA) technique for lung SBRT patients following RTOG protocols

To implement modified dynamic conformal arc (MDCA) technique and Radiation Therapy Oncology Group (RTOG) protocols in our clinic for stereotactic body radiation therapy (SBRT) treatment of patients with Stage I/II non–small cell lung cancer. Five patients with non–small cell lung cancer have been treated with SBRT. All the patients were immobilized using CIVCO Body Pro-Lok system and scanned using GE 4-slice computed tomography. The MDCA technique that was previously published was adopted as our planning technique, and RTOG protocols for the lung SBRT were followed. The patients were treated on Novalis Tx system with cone-beam computed tomography imaging guidance. All the patient plans passed the RTOG criteria. The conformal index ranges from 0.99 to 1.12 for the planning target volume, and the biological equivalent dose for the planning target volume is overall 100 Gy. Critical structures (lung, spinal cord, brachial plexus, skin, and chest wall) also meet RTOG protocols or published data. A 6-month follow-up of one of the patients shows good local disease control. We have successfully implemented the MDCA technique into our clinic for the lung SBRT program. It shows that the MDCA is useful and efficient for the lung SBRT planning, with the plan quality meeting the RTOG protocols.

61 RADIATION PROTECTION AND DOSIMETRY↗

On the possible benefits of a hybrid VMAT technique in the treatment of non–small cell lung cancer

To assess, using clinical cases, the potential of a hybrid technique for the treatment of non–small cell lung cancer (NSCLC)-blending volumetric-modulated arc therapy (VMAT) and conformal radiation therapy (CRT) fields, and to consider potential issues with implementation of such a technique. Eight clinical cases already treated with CRT were used for a planning study comparing target coverage and organs at risk (OAR) sparing between CRT and hybrid VMAT (VMATh). Quality assurance (QA) implications of the resultant hybrid plans are discussed. The hybrid technique resulted in superior target conformity or improved sparing of OAR or both. The hybrid technique shows promise, but the QA implications of motion at treatment need careful consideration.

61 RADIATION PROTECTION AND DOSIMETRY↗

Application of modified dynamic conformal arc (MDCA) technique on liver stereotactic body radiation therapy (SBRT) planning following RTOG 0438 guideline

Liver stereotactic body radiation therapy (SBRT) is a feasible treatment method for the nonoperable, patient with early-stage liver cancer. Treatment planning for the SBRT is very important and has to consider the simulation accuracy, planning time, treatment efficiency effects etc. The modified dynamic conformal arc (MDCA) technique is a 3-dimensional conformal arc planning method, which has been proposed for liver SBRT planning at our center. In this study, we compared the MDCA technique with the RapidArc technique in terms of planning target volume (PTV) coverage and sparing of organs at risk (OARs). The results show that the MDCA technique has comparable plan quality to RapidArc considering PTV coverage, hot spots, heterogeneity index, and effective liver volume. For the 5 PTVs studied among 4 patients, the MDCA plan, when compared with the RapidArc plan, showed 9% more hot spots, more heterogeneity effect, more sparing of OARs, and lower liver effective volume. The monitor unit (MU) number for the MDCA plan is much lower than for the RapidArc plans. The MDCA plan has the advantages of less planning time, no-collision treatment, and a lower MU number.

61 RADIATION PROTECTION AND DOSIMETRY↗

Deep inspiration breath-hold technique for left-sided breast cancer: An analysis of predictors for organ-at-risk sparing

To identify anatomic and treatment characteristics that correlate with organ-at-risk (OAR) sparing with deep inspiration breath-hold (DIBH) technique to guide patient selection for this technique. Anatomic and treatment characteristics and radiation doses to OARs were compared between free-breathing and DIBH plans. Linear regression analysis was used to identify factors independently predicting for cardiac sparing. We identified 64 patients: 44 with intact breast and 20 postmastectomy. For changes measured directly on treatment planning scans, DIBH plans decreased heart-chest wall length (6.5 vs 5.0 cm, p < 0.001), and increased lung volume (1074.4 vs 1881.3 cm{sup 3}, p < 0.001), and for changes measured after fields are set, they decreased maximum heart depth (1.1 vs 0.3 cm, p < 0.001) and heart volume in field (HVIF) (9.1 vs 0.9 cm{sup 3}, p < 0.001). DIBH reduced the mean heart dose (3.4 vs 1.8 Gy, p < 0.001) and lung V{sub 20} (19.6% vs 15.3%, p < 0.001). Regression analysis found that only change in HVIF independently predicted for cardiac sparing. We identified patients in the bottom quartile of the dosimetric benefits seen with DIBH and categorized the cause of this “minimal benefit.” Overall, 29% of patients satisfied these criteria for minimal benefit with DIBH and the most common cause was favorable baseline anatomy. Only the reduction in HVIF predicted for reductions in mean heart dose; no specific anatomic surrogate for the dosimetric benefits of DIBH technique could be identified. Most patients have significant dosimetric benefit with DIBH, and this technique should be planned and evaluated for all patients receiving left-sided breast/chest wall radiation.

61 RADIATION PROTECTION AND DOSIMETRY↗

Dosimetric study of volumetric arc modulation with RapidArc and intensity-modulated radiotherapy in patients with cervical cancer and comparison with 3-dimensional conformal technique for definitive radiotherapy in patients with cervical cancer

Introduction: For patients with cervical cancer, intensity-modulated radiation therapy (IMRT) improves target coverage and allows dose escalation while reducing the radiation dose to organs at risk (OARs). In this study, we compared dosimetric parameters among 3-dimensional conformal radiotherapy (3D-CRT), “step-and-shoot” IMRT, and volumetric intensity-modulated arc radiotherapy (VMAT) in a series of patients with cervical cancer receiving definitive radiotherapy. Computed tomography (CT) scans of 10 patients with histologically proven cervical cancer treated with definitive radiation therapy (RT) from December 2008 to March 2010 at our department were selected for this study. The gross tumor volume (GTV) and clinical target volume (CTV) were delineated following the guidelines of the Gyn IMRT consortium that included cervix, uterus, parametrial tissues, and the pelvic nodes including presacral. The median age was 57 years (range: 30 to 85 years). All 10 patients had squamous cell carcinoma with Federation of Gynecology and Obstetrics (FIGO) stage IB-IIIB. All patients were treated by VMAT. OAR doses were significantly reduced for plans with intensity-modulated technique compared with 3D-CRT except for the dose to the vagina. Between the 2 intensity-modulated techniques, significant difference was observed for the mean dose to the small intestine, to the benefit of VMAT (p < 0.001). There was no improvement in terms of OARs sparing for VMAT although there was a tendency for a slightly decreased average dose to the rectum: − 0.65 Gy but not significant (p = 0.07). The intensity modulation techniques have many advantages in terms of quality indexes, and particularly OAR sparing, compared with 3D-CRT. Following the ongoing technologic developments in modern radiotherapy, it is essential to evaluate the intensity-modulated techniques on prospective studies of a larger scale.

61 RADIATION PROTECTION AND DOSIMETRY↗

A feasibility study of using advanced external beam techniques to create a vaginal cuff brachytherapy-like endometrial boost plan

The purpose of this study was to explore the feasibility of using advanced external beam radiation therapy (EBRT) planning techniques for creating plans that could be used as a possible alternative for high-dose rate (HDR) vaginal cuff brachytherapy (VCBT) boost in treating endometrial cancer. The computed tomography (CT) images of a total of 4 female patients who had endometrial cancer treated with HDR-VCBT were selected for this study. A typical HDR-VCBT target volume, 0.5-cm-thick shell volume around the cylinder applicator in the prescribed treatment length was contoured and used as the planning target volume (PTV) in both the HDR VCBT and the EBRT VCBT-like plans. HDR-VCBT plans were made based on the clinical protocol, 6 Gy given at the cylinder surface. The EBRT plans were generated using either a 7-field intensity-modulated radiation therapy (IMRT) or a 2-arc volumetric-modulated arc therapy (VMAT) techniques for different cylinder sizes and treatment lengths, with the prescription dose of 5 Gy. Organs at risk (OARs) such as bladder, femoral heads, rectum, and sigmoid were also contoured and used in dosimetric evaluations. Dose-to-target metrics included mean dose, the dose covering 90% of target volume (D90) and the percentage of target volume covered by 90% of prescription dose (V90 or V13.5 Gy). Dose to OAR metrics included the maximum dose received by 0.1 cc (D0.1cc), 1.0 cc (D1.0cc), and 2.0 cc (D2.0cc) of OARs. These metrics were calculated and compared between all techniques. After the EBRT plans were normalized to achieve a comparable mean dose to target as HDR-VCBT, the EBRT plans were found to have superior target coverage and increased dose homogeneity compared with HDR-VCBT. V90s of EBRT plans were 95%, compared with 50% to 58% of the HDR plans. However, D0.1cc, D1.0cc, and D2.0cc of OARs were 2% to 38% lower in HDR-VCBT than in EBRT. Although HDR-VCBT plans demonstrated superior normal tissue sparing, both EBRT and HDR-VCBT plans produce plans that met clinical dose constraints on normal tissues. Advanced EBRT techniques such as IMRT and VMAT are capable of making plans, which closely resemble HDR-VCBT. Although the doses of OARs are greater in EBRT than in HDR-VCBT, the prescription dose coverage and dose homogeneity of the EBRT plans are greater than that of HDR-VCBT plans at the similar mean dose, and the OAR dose is still acceptable with EBRT plans. The detailed dosimetric approaches are provided in the study.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

AAA and AXB algorithms for the treatment of nasopharyngeal carcinoma using IMRT and RapidArc techniques

The aim of this study is to evaluate the impact of anisotropic analytical algorithm (AAA) and 2 reporting systems (AXB-D{sub m} and AXB-D{sub w}) of Acuros XB algorithm (AXB) on clinical plans of nasopharyngeal patients using intensity-modulated radiotherapy (IMRT) and RapidArc (RA) techniques. Six plans of different algorithm-technique combinations are performed for 10 patients to calculate dose-volume histogram (DVH) physical parameters for planning target volumes (PTVs) and organs at risk (OARs). The number of monitor units (MUs) and calculation time are also determined. Good coverage is reported for all algorithm-technique combination plans without exceeding the tolerance for OARs. Regardless of the algorithm, RA plans persistently reported higher D{sub 2%} values for PTV-70. All IMRT plans reported higher number of MUs (especially with AXB) than did RA plans. AAA-IMRT produced the minimum calculation time of all plans. Major differences between the investigated algorithm-technique combinations are reported only for the number of MUs and calculation time parameters. In terms of these 2 parameters, it is recommended to employ AXB in calculating RA plans and AAA in calculating IMRT plans to achieve minimum calculation times at reduced number of MUs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Electron postmastectomy chest wall plus comprehensive nodal irradiation technique using Electron Monte Carlo dose algorithm

For left-sided postmastectomy patients requiring chest wall plus comprehensive nodal irradiation, sometimes traditional techniques such as partial wide tangents or electron/tangents combination are not feasible due to abnormal chest wall contour or heart position or unusually wide excision scar. We developed electron chest wall irradiation technique using Electron Monte Carlo (EMC) dose algorithm that will achieve heart sparing with acceptable ipsilateral lung dose, minimal contralateral lung, and breast dose. Ten left-sided postmastectomy patients with very challenging anatomy were selected for this dosimetry study. The en face electron fields were designed from a single isocenter and gantry angle with different energy beams using different cutouts that matched on the skin. Smaller energy was used in the central thin chest wall part and higher energy in the medial internal mammary nodes (IMN) area, superior part of the thick chest wall, and/or axillary nodal area. The electron fields were matched to the photon supraclavicular field in the superior region. Daily field junctions were used to feather the match lines between all the fields. Electron field dose calculations were done with Monte Carlo. Five patients' chest wall fields were planned with 6/9MeVcombination, 1 with 6/12 MeV, 2 with 9/12 MeV, 1 with 9/16 MeV, and 1 with 6/9/12 MeV. Institutional criteria of prescription dose of 50 Gy for target volumes and normal tissue dose were met with this technique in spite of the challenging anatomy. Mean heart dose averaged 3.0 Gy ± 0.8 Gy. For ipsilateral lung, V20Gy and V5Gy averaged 33.2% ± 4.5% and 64.6% ± 9.6%, respectively. For contralateral lung, V5Gy averaged 5.1% ± 5.0%. For contralateral breast, V5Gy averaged 3.3% ± 3.1%. The electron chest wall irradiation technique using EMC dose algorithm can provide adequate dose coverage to the chest wall, IMNs, and/or axillary nodes while achieving heart sparing with acceptable ipsilateral lung dose, minimal contralateral lung, and breast dose.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

An overview of HR-EBSD techniques for mapping local stress and dislocations in crystalline materials at sub-micron resolution

High resolution electron backscatter diffraction (HR-EBSD) is a technique used to map elastic strain, crystallographic orientation and dislocation density in a scanning electron microscope. Here, this review covers the background and mathematics of this technique, contextualizing it within the broader landscape of EBSD techniques and other materials characterization methods. Several case studies are presented showing the application of HR-EBSD to the study of plasticity in metals, failure analysis in microelectronics and defect quantification in thin films. This is intended to be a comprehensive resource for researchers developing this technique as well as an introduction to those wishing to apply it.

Ruggles, Timothy J. [Sandia National Laboratories ↗