Hamilton: Flexible, Open Source $10 Wireless Sensor System for Energy Efficient Building Operation

Sensors for improving building performance are rapidly populating the market, driven in part by the drive to reduce greenhouse gas emissions resulting from energy production as well as improve the interior environment for healthy and more productive spaces. UC Berkeley has led wireless sensor development over the past 25 years (e.g., Telos mote), with the Hamilton (named after Alexander Hamilton on the US $10 bill) as the most recent. The Hamilton sensor was designed as a low-cost high-performance sensor that is modular and interoperable. The objective of the Hamilton project was to create, evaluate and establish the technological foundations for secure and easy to deploy building energy efficiency applications utilizing pervasive, low-cost wireless sensors integrated with traditional Building Management Systems (BMS), consumer-sector building components, and powerful data analytics. The project included iterative hardware design, incorporating a high-performance database (BTrDb, http://btrdb.io/), creating and iterating the development of secure data middleware (BOSSwave, WAVE/WAVEMQ), working with and pushing the development of an open-source tiny operating system RiotOS, and implementing and improving protocols such as Thread/OpenThread and TCP/IP. The hardware benefited from careful design to drive down the cost; the design included a System-on-a-Chip (SoC), chip antenna, single crystal and five passive components. Careful design of the operating system created a low-power design to enable a long life with small batteries. The hardware included several sensors: temperature, radiant temperature, relative humidity, magnetometer, accelerometer, and light, with an optional occupancy (Passive InfraRed) sensor. The project was the basis of several applications, both internal to the research team and other researchers and professionals at other institutions. Several applications used the sensor hardware as the basis for other complex devices. Other applications used the sensors to improve building performance through interoperating with the building Heating Ventilation and Air-Conditioning (HVAC) system, such as using occupancy and/or distributed temperature sensing to reduce HVAC zone energy while still providing thermal comfort and to reduce peak loads in small commercial buildings. We demonstrated cloud-based energy analytics, implemented a schedule and a Model Predictive Controller in a small commercial building to optimize HVAC energy, occupancy and electricity price. Initial integration of these technological innovations was performed through the creation of execution containers containing the WAVE agent and various driver, proxy, or building system function logic. The research added to the understanding of efficient sensor hardware, secure middleware, time-series data management (high performance database), efficient communication protocols, and interoperating with applications and building systems. The project showed the technical effectiveness and economic feasibility of creating a low-cost, modular, and easy-to-deploy sensor. Through conversations with multiple end users, the research team discovered that many customers wanted data management and services in addition to the sensors. HamiltonIOT developed packages of sensors, border router, and data services to provide a seamless “plug-and-play” sensor deployment. Some customers were willing to pay for higher quality sensors (such as light); some customers wanted a robust enclosure (waterproof).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Microcam: A Low Power and Privacy Preserving Multi-modal Platform for Occupancy Detection (Final Report)

Heating, ventilation, and air conditioning (HVAC) consumes a significant portion of the energy used in buildings. Much of this is wasted energy, used when buildings are either not occupied at all, or occupied well under their maximum design conditions. This project has focused on residential occupancy detection to autonomously control HVAC systems and save energy. Limitations of existing occupancy sensors include one or more of the following: (i) they employ sensors or algorithms that are not able to detect stationary occupants; (ii) they cannot classify the source of the motion (such as a pet); (iii) depending on the camera resolution and employed algorithms, they do not allow for embedded or onboard computation, and require external or cloud-based processing; (iv) many algorithms developed for camera-based systems are sensitive to lighting changes, and thus prone to missed detections or false alarms; (v) Most existing systems depend on adjustment of settings for different scenarios, complicating self-commissioning; (vi) they cannot provide high enough accuracy; (vii) they are costly; (viii) they are not battery-powered, thus limiting ease of use and installation. In this project, Syracuse University and its partner SRI have developed a low-cost, high accuracy, standalone residential occupancy sensing platform, referred to as the MicroCam, to address all of the aforementioned challenges. MicroCam can operate on typical alkaline batteries without relying on the “cloud” or external computing resources, and consists of low-power, Artificial Intelligence (AI)-based, IoT platforms. Each platform has multi-modal sensors and can process motion, audio and video data, and send binary occupancy result to a lead platform. All sensor data is processed locally on platforms, and the only transmitted data is the binary occupancy state. In addition, preliminary work has been done on images wherein occupants are not discernable. Thus, MicroCam is a standalone solution preserving privacy of the occupants.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

NASA ISS Portable Fan Assembly Acoustics

The Portable Fan Assembly (PFA) is a variable speed fan that can be used to provide additional ventilation inside International Space Station (ISS) modules as needed for crew comfort or for enhanced mixing of the ISS atmosphere. This fan can also be configured with a Shuttle era lithium hydroxide (LiOH) canister for CO2 removal in confined areas partially of fully isolated from the primary Environmental Control and Life Support System (ECLSS) on ISS which is responsible for CO2 removal. This report documents noise emission levels of the PFA at various speed settings and configurations. It also documents the acoustic attenuation effects realized when circulating air through the PFA inlet and outlet mufflers and when operating in its CO2 removal configuration (CRK) with a LiOH canister (sorbent bed) installed over the fan outlet.

Boone, Andrew↗

Airflow Simulations around OA Intake Louver with Electronic Velocity Sensors

It is important to control outdoor airflow rates into HVAC systems in terms of energy conservation and healthy indoor environment. Technologies are being developed to measure outdoor air (OA) flow rates through OA intake louvers on a real time basis. The purpose of this paper is to investigate the airflow characteristics through an OA intake louver numerically in order to provide suggestions for sensor installations. Airflow patterns are simulated with and without electronic air velocity sensors within cylindrical probes installed between louver blades or at the downstream face of the louver. Numerical results show quite good agreements with experimental data, and provide insights regarding measurement system design. The simulations indicate that velocity profiles are more spatially uniform at the louver outlet relative to between louver blades, that pressure drops imposed by the sensor bars are smaller with sensor bars at the louver outlet, and that placement of the sensor bars between louver blades substantially increases air velocities inside the louver. These findings suggest there is an advantage to placing the sensor bars at the louver outlet face.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Heat dissipation in controlled environment enclosures through the application of water screens

The use of plate glass-water thermal barriers in controlled environment facilities effectively reduces the thermal load within the plant growth chamber. This allows high PPFs to be provided for plant growth and development studies, adequate simulation of daily light integrals, and simulation of peak PPF's. Further, substantial amounts of incandescent lamp supplementation can be used to achieve simulation of daylight R:FR ratios which are needed to ensure adequate stem development in some species. While the focus in this paper is on the use of entire thermal barriers which separate the lighting enclosure from the plant growth chamber, the same principles apply to the use of water jackets for cooling individual lamps (such as can occur with xenon-arc lamps). In this instance, the barrier separating the lamps from the plant chamber can be much simpler (e.g., plexiglass) as the main function of the barrier is to separate the air ventilation of the lamp enclosure from the air system within the plant growth chamber. The main advantage of water as a thermal barrier is the negligible absorption of radiation in the photosynthetically-active and near infrared wavebands. Consequently, plate glass-water barriers typically allow transmission of approximately 90% of radiation in these regions. While ventilated double and triple glazing systems appear to be attractive alternative to water barriers from an operating standpoint, their significant absorption in the biologically-important wavebands (7 - 12%) with each glass layer and longer-wave cut-offs (typically 2500 - 4000 nm) makes them a much less attractive alternative. The data presented here demonstrate clearly that measurement of PPF alone is not an adequate representation of the radiation environment being used in a controlled environment study. The amounts and proportions of long-wave and short-wave radiation in a plant growth chamber are dependent on lamp type, lamp combination, presence of a thermal barrier, the type of thermal barrier between the lamps and the plant growing area and the overall construction and design of the chamber. It is important, therefore, in reporting results of controlled environment studies, to adequately describe both the details of the lighting system used and the characteristics of the radiation produced by that system, so results of different studies can be adequately evaluated and compared.

Warrington, I. J.↗

Moving Beyond Mortality: Development and Application of a Desirability of Outcome Ranking (DOOR) Endpoint for Hospital-Acquired Bacterial Pneumonia and Ventilator-Associated Bacterial Pneumonia

Abstract Background Hospital-acquired and ventilator-associated bacterial pneumonia (HABP/VABP) are frequently caused by multidrug-resistant organisms. Patient-centered endpoints in clinical trials are needed to develop new antibiotics for HABP/VABP. Desirability of outcome ranking (DOOR) is a paradigm for the design, analysis, and interpretation of clinical trials based on a patient-centered, benefit-risk evaluation. Methods A multidisciplinary committee created an infectious diseases DOOR endpoint customized for HABP/VABP, incorporating infectious complications, serious adverse events, and mortality. We applied this to 2 previously completed, large randomized controlled trials for HABP/VABP. ZEPHyR compared vancomycin to linezolid and VITAL compared linezolid to tedizolid. For each trial, we evaluated the DOOR distribution and probability, including DOOR component and partial credit analyses. We also applied DOOR in subgroup analyses. Results In both trials, the HABP/VABP DOOR demonstrated similar overall clinical outcomes between treatment groups. In ZEPHyR, the probability that a participant treated with linezolid would have a more desirable outcome than a participant treated with vancomycin was 50.2% (95% confidence interval [CI], 45.1%­−55.3%). In VITAL, the probability that a participant treated with tedizolid would have a more desirable outcome than a participant treated with linezolid was 48.7% (95% CI, 44.8%–52.6%). The DOOR component analysis revealed that participants treated with tedizolid had a less desirable outcome than those treated with linezolid when considering clinical response alone. However, participants with decreased renal function had improved overall outcomes with tedizolid. Conclusions The HABP/VABP DOOR provided more granular information about clinical outcomes than is typically presented in clinical trials. HABP/VABP trials would benefit from prospectively using DOOR.

Immunology↗

Distributed Flexibility Characterization and Resource Allocation Strategies for Multi-zone Commercial Buildings in the Smart Grid

The HVAC (Heating, Ventilation, and Air- Conditioning) system of commercial buildings is a complex system with a large number of dynamically interacting components. In particular, the thermal dynamics of each zone are coupled with those of the neighboring zones. In this paper, we study a multi-agent based approach to model and control commercial building HVAC system for providing grid services. In the multi-agent system (MAS), individual zones are modeled as agents that can communicate, interact, and negotiate with one another to achieve a common objective. We first propose a distributed characterization method on the aggregated airflow (and thus fan power) flexibility that the HVAC system can provide to the ancillary service market. Then, we propose a Nash-bargaining based airflow allocation strategy to track a dispatch signal (that is within the offered flexibility limit) while respecting the preference and flexibility of individual zones. Moreover, we devise a distributed algorithm to obtain the Nash bargaining solution via dual decomposition and average consensus. Numerical simulations illustrate that the proposed distributed protocols are much more scalable than the centralized approaches especially when the system becomes larger and more complex.

Hao, He↗

Maintaining Adequate CO2 Washout for an Advanced EMU via a New Rapid Cycle Amine Technology

Over the past several years, NASA has realized tremendous progress in Extravehicular Activity (EVA) technology development. This has been evidenced by the progressive development of a new Rapic Cycle Amine (RCA) system for the Advanced Extravehicular Mobility Unit (AEMU) Portable Life Support Subsystem (PLSS). The PLSS is responsible for the life support of the crew member in the spacesuit. The RCA technology is responsible for carbon dioxide (CO2) and humidity control. Another aspect of the RCA is that it is on-back vacuum-regenerable, efficient, and reliable. The RCA also simplifies the PLSS schematic by eliminating the need for a condensing heat exchanger for humidity control in the current EMU. As development progresses on the RCA, it is important that the sizing be optimized so that the demand on the PLSS battery is minimized. As well, maintaining the CO2 washout at adequate levels during an EVA is an absolute requirement of the RCA and associated ventilation system. Testing has been underway in-house at NASA Johnson Space Center and analysis has been initiated to evaluate whether the technology provides exemplary performance in ensuring that the CO2 is removed sufficiently enough and the ventilation flow is adequate enough to maintain CO2 1 Project Engineer, Space Suit and Crew Survival Systems Branch, Crew and Thermal Systems Division, 2101 NASA Parkway, Houston, TX 77058/EC5. washout in the AEMU spacesuit helmet of the crew member during an EVA. This paper will review the recent developments of the RCA unit, the testing results performed in-house with a spacesuit simulator, and the associated analytical work along with insights from the medical aspect on the testing.

Chullen, Cinda↗

Maintaining Adequate CO2 Washout for an Advanced EMU via a New Rapid Cycle Amine Technology

Over the past several years, NASA has realized tremendous progress in Extravehicular Activity (EVA) technology development. This has been evidenced by the progressive development of a new Rapid Cycle Amine (RCA) system for the Advanced Extravehicular Mobility Unit (AEMU) Portable Life Support Subsystem (PLSS). The PLSS is responsible for the life support of the crew member in the spacesuit. The RCA technology is responsible for carbon dioxide (CO2) and humidity control. Another aspect of the RCA is that it is on-back vacuum-regenerable, efficient, and reliable. The RCA also simplifies the PLSS schematic by eliminating the need for a condensing heat exchanger for humidity control in the current EMU. As development progresses on the RCA, it is important that the sizing be optimized so that the demand on the PLSS battery is minimized. As well, maintaining the CO2 washout at adequate levels during an EVA is an absolute requirement of the RCA and associated ventilation system. Testing has been underway in-house at NASA Johnson Space Center and analysis has been initiated to evaluate whether the technology provides exemplary performance in ensuring that the CO2 is removed sufficiently and the ventilation flow is adequate for maintaining CO2 washout in the AEMU spacesuit helmet of the crew member during an EVA. This paper will review the recent developments of the RCA unit, testing planned in-house with a spacesuit simulator, and the associated analytical work along with insights from the medical aspect on the testing. 1

Chullen, Cinda↗

A Study of the Energy-Saving Potential of Metal Roofs Incorporating Dynamic Insulation Systems

This article presents various metal roof configurations that were tested at Oak Ridge National Laboratory in Tennessee, U.S. between 2009 and 2013, and describes their potential for reducing the attic-generated space-conditioning loads. These roofs contained different combinations of phase-change material, rigid insulation, low emittance surface, and above-sheathing ventilation with standing-seam metal panels on top. These roofs were designed to be installed on existing roofs decks, or on top of asphalt shingles for retrofit construction. All the tested roofs showed the potential for substantial energy savings compared to an asphalt shingle roof, which was used as a control for comparison. The roofs were constructed on a series of adjacent attics separated at the gables using thick foam insulation. The attics were built on top of a conditioned room. All attics were vented at the soffit and ridge. The test roofs and attics were instrumented with an array of thermocouples. Heat flux transducers were installed in the roof deck and attic floor (ceiling) to measure the heat flows through the roof and between the attic and conditioned space below. Temperature and heat flux data were collected during the heating, cooling and swing seasons over a three-year period. Data from previous years of testing have been published. Here, data from the latest roof configurations being tested in year three of the project are presented. All test roofs were highly effective in reducing the heat flows through the roof and ceiling, and in reducing the diurnal attic-temperature fluctuations.

Biswas, Kaushik↗

Mechanical Ventilator Milano (MVM): A Novel Mechanical Ventilator Designed for Mass Scale Production in Response to the COVID-19 Pandemics

We present here the design of the Mechanical Ventilator Milano (MVM), a novel mechanical ventilator designed for mass scale production in response to the COVID-19 pandemics, to compensate for the dramatic shortage of such ventilators in many countries. This ventilator is an electro-mechanical equivalent of the old, reliable Manley Ventilator. Our design is optimized to permit large sale production in short time and at a limited cost, relying on off-the-shelf components, readily available worldwide from hardware suppliers. Operation of the MVM requires only a source of compressed oxygen (or compressed medical air) and electrical power. The MVM control and monitoring unit can be connected and networked via WiFi so that no additional electrical connections are necessary other than the connection to the electrical power. At this stage the MVM is not a certified medical device. Construction of the first prototypes is starting with a team of engineers, scientists and computing experts. The purpose of this paper is to disseminate the conceptual design of the MVM broadly and to solicit feedback from the scientific and medical community to speed the process of review, improvement and possible implementation.

Galbiati, C.↗

Adsorption of Iodine and Tritium from UNF Reprocessing Off-Gas Streams

The need to control emissions of the gaseous radionuclides to the air during nuclear fuel recycling is widely recognized. Gaseous radionuclides can partition to off-gas streams emanating from the various individual processes used in the recycle plant, such as from the mechanical head end (shear), tritium pretreatment, fuel dissolver, vessel vents, cell ventilation, and conversion operations. In traditional recycle plants, the bulk of the four primary volatile fission products (i.e., {sup 3}H, {sup 14}C, {sup 85}Kr, and {sup 129}I) is released in the head-end processes, for example, the dissolution process. The usual off-gas treatment sequence of operations targets removal of tritium (as {sup 3}HHO), iodine, carbon (as {sup 14}CO{sub 2}), and the noble gases, in that order. Water and iodine are captured first because the other species are relatively unimpeded by the sorbents used for water and iodine, so they flow downstream to additional treatment processes. Water and iodine do react with one another, and many techniques used to collect one of these species also collect some fraction of the other. It is quite desirable to sequester the iodine and water separately because the tritiated water may be disposed of as a low level waste. If not cleanly separated, contamination of the low-level waste by iodine may elevate its classification to high-level waste and result in greater costs for disposal. The proposed sorption sequence was tested in the laboratory. Use of a second column of AgZ permits the detection of breakthrough from the primary AgZ column while protecting the downstream 3AMS column from collecting iodine. (This arrangement is equivalent to enabling intra-column sampling of the primary column.) Neutron activation analysis of the 3AMS revealed that iodine was below, or at, the level of detection. The results successfully demonstrated that iodine can be sequestered in the AgZ while the water is collected free of iodine in the 3AMS column. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Evaluating the Performance and Economics of Transpired Solar Collectors for Commercial Applications

Using transpired solar collectors to preheat ventilation air has recently become recognized as an economic alternative for integrating renewable energy into commercial buildings in heating climates. The collectors have relatively low installed costs and operate on simple principles. Theory and performance testing have shown that solar collection efficiency can exceed 70% of incident solar. However, implementation and current absorber designs have adversely affected the efficiency and associated economics from this initial analysis. The National Renewable Energy Laboratory (NREL) has actively studied this technology and monitored performance at several installations. A calibrated model that uses typical meteorological weather data to determine absorber plate efficiency resulted from this work. With this model, an economic analysis across heating climates was done to show the effects of collector size, tilt, azimuth, and absorptivity. The analysis relates the internal rate of return of a system based on the cost of the installed absorber area. In general, colder and higher latitude climates return a higher rate of return because the heating season extends into months with good solar resource. Wal-Mart has installed approximately 8,000 ft{sup 2} of absorber at its experimental store in Aurora, Colorado. The delivered energy efficiency was measured at 8-11% during January and February 2007. The low collection efficiency is largely due to the oversized absorber and to the multizone control strategy that limits the amount of air pulled through the collector. Analysis shows that more than 50% of the incident solar energy could be delivered with proper control strategy changes.

14 SOLAR ENERGY↗

Potential Indoor Worker Exposure From Handling Area Leakage: Dose Calculation Methodology and Example Consequence Analysis

The U.S. Department of Energy (DOE) is currently considering design options for preclosure facilities in a license application for a geologic repository for spent nuclear fuel and high-level radioactive waste at Yucca Mountain, Nevada. The Center for Nuclear Waste Regulatory Analyses (CNWRA) developed the PCSA Tool Version 3.0.0 software for the U.S. Nuclear Regulatory Commission (NRC) to aid in the regulatory review of a potential DOE license application. The objective of this paper is to demonstrate PCSA Tool modeling capabilities (i.e., a generic two-compartment, mass-balance model) for estimating radionuclide concentrations in air and radiological dose consequences to indoor workers in a control room from potential leakage of radioactively contaminated air from an adjacent handling area. The presented model computes internal and external worker doses from inhalation and submersion in a finite cloud of contaminated air in the control room and augments previous capabilities for assessing indoor worker dose. As a complement to the example event sequence frequency analysis in the companion paper, example consequence calculations are presented in this paper for the postulated event sequence. In conclusion: this paper presents a model for estimating radiological doses to indoor workers for the leakage of airborne radioactive material from handling areas. Sensitivity of model results to changes in various input parameters was investigated via illustrative example calculations. Indoor worker dose estimates were strongly dependent on the duration of worker exposure and the handling-area leakage flow rate. In contrast, doses were not very sensitive to handling-area exhaust ventilation flow rates. For the presented example, inhalation was the dominant radiological dose pathway. The two companion papers demonstrate independent analysis capabilities of the regulator for performing confirmatory calculations of frequency and consequence, which assist the assessment of worker safety during a risk-informed regulatory review of a potential DOE license application.

61 RADIATION PROTECTION AND DOSIMETRY↗

Enclosure fire hazard analysis using relative energy release criteria

A method for predicting the probable course of fire development in an enclosure is presented. This fire modeling approach uses a graphic plot of five fire development constraints, the relative energy release criteria (RERC), to bound the heat release rates in an enclosure as a function of time. The five RERC are flame spread rate, fuel surface area, ventilation, enclosure volume, and total fuel load. They may be calculated versus time based on the specified or empirical conditions describing the specific enclosure, the fuel type and load, and the ventilation. The calculation of these five criteria, using the common basis of energy release rates versus time, provides a unifying framework for the utilization of available experimental data from all phases of fire development. The plot of these criteria reveals the probable fire development envelope and indicates which fire constraint will be controlling during a criteria time period. Examples of RERC application to fire characterization and control and to hazard analysis are presented along with recommendations for the further development of the concept.

Coulbert, C. D.↗

Experimental system, and its evaluation for the control of surgically inducted infections

The effect is reported to design, fabricate, test and evaluate a prototype experimental system for the control of surgically induced infections. The purpose is to provide the cleanest possible environment within a hospital surgery room and eliminate contamination sources that could cause infections during surgery. The system design is described. The system provides for a portable laminar flow clean room, a full bubble helmet system with associated communications and ventilation subsystems for operating room personnel, and surgical gowns that minimize the migration of bacteria. The development test results consisting of portability, laminar flowrate, air flow pattern, electrostatic buildup, noise level, ventilation, human factors, electrical and material compatibility tests are summarized. The conclusions are that the experimental system is effective in reducing the airborne and wound contamination although the helmets and gowns may not be a significant part of this reduction. Definitive conclusions with regard to the infection rate cannot be made at this time.

Tevebaugh, M. D.↗

Simulated Lunar Testing of Metabolic Heat Regenerated Temperature Swing Adsorption Technology

Metabolic heat regenerated Temperature Swing Adsorption (MTSA) technology is being developed for thermal and carbon dioxide (CO2) control for a Portable Life Support System (PLSS), as well as water recycling. An Engineering Development Unit (EDU) of the MTSA subassembly was designed and assembled for optimized Martian operations, but also meets system requirements for lunar operations. For lunar operations the MTSA sorption cycle is driven via a vacuum swing between suit ventilation loop pressure and lunar vacuum. The focus of this effort is operations and testing in a simulated lunar environment. This environment was simulated in Paragon s EHF vacuum chamber. The objective of this testing was to evaluate the full cycle performance of the MTSA Subassembly EDU, and to assess CO2 loading and pressure drop of the wash coated aluminum reticulated foam sorbent bed. The lunar testing proved out the feasibility of pure vacuum swing operation, making MTSA a technology that can be tested and used on the Moon prior to going to Mars. Testing demonstrated better than expected CO2 loading on the sorbent and nearly replicates the equilibrium data from the sorbent manufacturer. This had not been achieved in any of the previous sorbent loading tests performed by Paragon. Subsequently, the increased performance of the sorbent bed design indicates future designs will require less mass and volume than the current EDU rendering MTSA as very competitive for Martian PLSS applications.

Padilla, Sebastian A.↗

Use of Thermoregulatory Models to Enhance Space Shuttle and Space Station operations and Review of Human Thermoregulatory Control

Thermoregulation in the space environment is critical for survival, especially in off- nominal operations. In such cases, mathematical models of thermoregulation are frequently employed to evaluate safety-of-flight issues in various human mission scenarious. In this study, the 225-node Wissler model and the 41-Node Metabolic Man model are employed to evaluate the effects of such a scenario. Metabolic loads on astronauts wearing the advanced crew escape suit (ACES) and liquid cooled ventilation garment (LCVG) are imposed on astronauts exposed to elevated cabin temperatures resulting from a systems failure. The study indicates that the performance of the ACES/LCVG cooling system is marginal. Increases in workload and or cabin temperature above nominal will increase rectal temperature, stored heat load, heart rate, and sweating, which could lead to deficits in the performance of cognitive and motor tasks. This is of concern as the ACES/LCVG is employed during Shuttle decent when the likelihood of a safe landing may be compromised. The study indicates that the most effective mitigation strategy would be to decrease the LCVG inlet temperature.

Pisacane, V. L.↗