At least 739 records · Page 41

Search for Axionlike-Particle-Induced Prompt γ-Ray Emission from Extragalactic Core-Collapse Supernovae with the Fermi Large Area Telescope

During a core-collapse supernova (SN), axionlike particles (ALPs) could be produced through the Primakoff process and subsequently convert into γ rays in the magnetic field of the Milky Way. We do not find evidence for such a γ -ray burst in observations of extragalactic SNe with the Fermi Large Area Telescope (LAT). The SN explosion times are estimated from optical light curves and we find a probability of about ~90% that the LAT observed at least one SN at the time of the core collapse. Under the assumption that at least one SN was contained within the LAT field of view, we exclude photon-ALP couplings ≳ 2.6 × 10 -12 GeV -1 for ALP masses m a ≲ 3 × 10 -10 eV , improving previous limits from SN1987A by a factor of 2.

79 ASTRONOMY AND ASTROPHYSICS↗

Soybean canopy reflectance modeling data sets

Numerous mathematical models of the interaction of radiation with vegetation canopies have been developed over the last two decades. However, data with which to exercise and validate these models are scarce. During three days in the summer of 1980, experiments are conducted with the objective of gaining insight about the effects of solar illumination and view angles on soybean canopy reflectance. In concert with these experiment, extensive measurements of the soybean canopies are obtained. This document is a compilation of the bidirectional reflectance factors, agronomic, characteristics, canopy geometry, and leaf, stem, and pod optical properties of the soybean canopies. These data sets should be suitable for use with most vegetation canopy reflectance models.

Ranson, K. J.↗

Quantitative analysis of hard X-ray 'footpoint' flares observed by the solar maximum mission

Amplifier gain and collimator hole size variations across the field of view, amplifier/filter efficiency, variations in effective collimator hole size and angular response with photon energy, dead-time, and hard X-ray plate transmission, are among the factors for which instrumental corrections have to be incorporated to effect reliable correction and deconvolution of images from the SMM satellite's Hard X-ray Imaging Spectrometer (HXIS). Attention is given to the substantial Poisson noise in these energy bands. The maximum entropy deconvolution/correction routine developed for establishing the spatial structure reliably inferrable from HXIS data is presented, together with the results of the application of this routine to the three impulsive flares reported by Duijemian et al. (1982) from April 10, May 21, and November 5, 1980.

Mackinnon, A. L.↗

Solar magnetic field studies using the 12 micron emission lines. I - Quiet sun time series and sunspot slices

The use of the extremely Zeeman-sensitive IR emission line Mg I, at 12.32 microns, to study solar magnetic fields. Time series observations of the line in the quiet sun were obtained in order to determine the response time of the line to the five-minute oscillations. Based upon the velocity amplitude and average period measured in the line, it is concluded that it is formed in the temperature minimum region. The magnetic structure of sunspots is investigated by stepping a small field of view in linear 'slices' through the spots. The region of penumbral line formation does not show the Evershed outflow common in photospheric lines. The line intensity is a factor of two greater in sunspot penumbrae than in the photosphere, and at the limb the penumbral emission begins to depart from optical thinness, the line source function increasing with height. For a spot near disk center, the radial decrease in absolute magnetic field strength is steeper than the generally accepted dependence.

Deming, Drake↗

PLAID as a maintainability tool

PLAID is a computer-aided design tool for human factors engineering which has been used successfully in the Space Shuttle program and for design analysis of Space Station Freedom. PLAID capability includes analysis of visual fields of view, of the ability to reach a specified point, and of spatial conflicts. It enables the creation of animations which depict whole sequences of motions of astronauts and equipment. The PLAID graphics capability is described and its application to man-systems integration is briefly examined. The use of PLAID for maintainability is addressed, and future plans for PLAID are discussed.

Woolford, Barbara J.↗

Shortwave shape factor inversion of earth radiation budget observations

Results are presented on an investigation of the effects of various assumptions (including assumptions of a constant flux field, a constant albedo field, and a variable albedo field) used for deriving the shortwave shape factor on the estimates, from radiometric measurements, of the albedo at the top of the atmosphere. The accuracies and the resolutions of the shape-factor-flux estimates obtained using these assumptions are determined by simulating the shape factor inversion technique with scanner data from the Earth Radiation Budget Experiment (ERBE). The resulting biases and variances are given for both the ERBE medium-field-of-view and wide-field-of-view radiometers.

Green, Richard N.↗

Three-dimensional surface grid generation for calculation of thermal radiation shape factors

A technique is described to generate three dimensional surface grids suitable for calculating shape factors for thermal radiative heat transfer. The surface under consideration is approximated by finite triangular elements generated in a special manner. The grid is generated by dividing the surface into a two dimensional array of nodes. Each node is defined by its coordinates. Each set of four adjacent nodes is used to construct two triangular elements. Each triangular element is characterized by the vector representation of its vertices. Vector algebra is used to calculate all desired geometric properties of grid elements. The properties are used to determine the shape factor between the element and an area element in space. The grid generation can be graphically displayed using any software with three dimensional features. DISSPLA was used to view the grids.

Aly, Hany M.↗

Anomalous ion mixing within a Kelvin-Helmholtz vortex in a collisionless plasma

Anomalously fast ion mixing is observed in a hybrid code simulation (particle ions and a massless electron fluid) of the Kelvin-Helmholtz instability in a collisionless plasma. While the traditional view predicts that the ion mixing occurs on a time scale longer than the roll-up time T(v) of the Kelvin-Helmholtz vortex by a factor of (velocity shear scale length)/(ion Larmor radius), the simulation results show that the mixing occurs within a time scale comparable to T(v). It is shown that this fast mixing is due to the scattering of ions by unsteady electromagnetic fields.

Terasawa, T.↗

Evidence of active region imprints on the solar wind structure

A common descriptive framework for discussing the solar wind structure in the inner heliosphere uses the global magnetic field as a reference: low density, high velocity solar wind emanates from open magnetic fields, with high density, low speed solar wind flowing outward near the current sheet. In this picture, active regions, underlying closed magnetic field structures in the streamer belt, leave little or no imprint on the solar wind. We present evidence from interplanetary scintillation measurements of the 'disturbance factor' g that active regions play a role in modulating the solar wind and possibly contribute to the solar wind mass output. Hence we find that the traditional view of the solar wind, though useful in understanding many features of solar wind structure, is oversimplified and possibly neglects important aspects of solar wind dynamics

Hick, P.↗

Evaluation and Treatment of Essential Hypertension During Short Duration Space Flight

During the last four decades of manned space flight, two individuals have successfully flown in space with the preflight diagnosis of essential hypertension (HTN). Treatment of this disease process in the astronaut population warrants special consideration particularly when selecting medication for a mission. A retrospective review of data offers two different clinical scenarios involving the treatment, or lack thereof, for essential hypertension during space flight. Case I; A Caucasian quinquagenerian diagnosed with HTN one year prior to the mission obtained flight certification after a negative diagnostic workup. The patient was placed on a diuretic. Preflight isolated blood pressure (BP) measurements averaged 138/102. Inflight, the patient electively declined medication. A 36-hour BP monitor revealed an average value of 124/87. Postflight, BP measurements returned to preflight BP values. Case II: A Caucasian quatrogenerian diagnosed with HTN 6 months prior to launch completed flight training after a negative diagnostic workup. The patient was placed on an ACE inhibiter. Preflight BP measurements averaged 130/80. Inflight, isolated BP measurements were considerably less. Normotensive values were obtained postflight. In both cases, BP values inflight were lower than pre or postflight values. Yelle et al has confirmed similar findings in the normotensive astronaut population. Spaceflight may result in fluid shifting, mild dehydration, electrolyte imbalance, orthostatic hypotension, and increased heart rates. Based on these factors, certain classes of antihypertensive agents such as vasodilators, beta-blockers, and diuretics are excluded from consideration as a primary therapeutic modality. To date, Ace Inhibitors are viewed as the more acceptable drug of choice during spaceflight. Newer classes of drugs may also provide additional choices. Presently, astronauts developing uncomplicated HTN may continue their careers when treated with the appropriate class of continue their careers when treated with the appropriate class of antihypertensive medication.

Rossum, Alfred C.↗

Nickel-Cadmium Battery Operation Management Optimization Using Robust Design

In recent years following several spacecraft battery anomalies, it was determined that managing the operational factors of NASA flight NiCd rechargeable battery was very important in order to maintain space flight battery nominal performance. The optimization of existing flight battery operational performance was viewed as something new for a Taguchi Methods application.

NiCd rechargeable battery Taguchi Methods applicat↗

On-Orbit Performance and Calibration Improvements For the Reflective Solar Bands of Terra and Aqua MODIS

Moderate Resolution Imaging Spectroradiometer (MODIS) is the keystone instrument for NASAs EOS Terra and Aqua missions, designed to extend and improve heritage sensor measurements and data records of the land, oceans and atmosphere. The reflective solar bands (RSB) of MODIS covering wavelengths from 0.41 micrometers to 2.2 micrometers, are calibrated on-orbit using a solar diffuser (SD), with its on-orbit bi-directional reflectance factor (BRF) changes tracked using a solar diffuser stability monitor (SDSM). MODIS is a scanning radiometer using a two-sided paddle-wheel mirror to collect earth view (EV) data over a range of (+/-)55 deg. off instrument nadir. In addition to the solar calibration provided by the SD and SDSM system, lunar observations at nearly constant phase angles are regularly scheduled to monitor the RSB calibration stability. For both Terra and Aqua MODIS, the SD and lunar observations are used together to track the on-orbit changes of RSB response versus scan angle (RVS) as the SD and SV port are viewed at different angles of incidence (AOI) on the scan mirror. The MODIS Level 1B (L1B) Collection 6 (C6) algorithm incorporated several enhancements over its predecessor Collection 5 (C5) algorithm. A notable improvement was the use of the earth-view (EV) response trends from pseudo-invariant desert targets to characterize the on-orbit RVS for select RSB (Terra bands 1-4, 8, 9 and Aqua bands 8, 9) and the time, AOI, and wavelength-dependent uncertainty. The MODIS Characterization Support Team (MCST) has been maintaining and enhancing the C6 algorithm since its first update in November, 2011 for Aqua MODIS, and February, 2012 for Terra MODIS. Several calibration improvements have been incorporated that include extending the EV-based RVS approach to other RSB, additional correction for SD degradation at SWIR wavelengths, and alternative approaches for on-orbit RVS characterization. In addition to the on-orbit performance of the MODIS RSB, this paper also discusses in detail the recent calibration improvements implemented in the MODIS L1B C6.

Angal, Amit↗

Nonleptonic B{sub s} to charmonium decays: Analysis in pursuit of determining the weak phase {beta}{sub s}

We analyze nonleptonic B{sub s} decays to a charmonium state and a light meson, induced by the b{yields}ccs transition, which are useful to access the B{sub s}-B{sub s} mixing phase {beta}{sub s}. We use generalized factorization and SU(3){sub F} symmetry to relate such modes to correspondent B decay channels. We discuss the feasibility of the measurements in the various channels, stressing the importance of comparing different determinations of {beta}{sub s} in view of the hints of new physics effects recently emerged in the B{sub s} sector. Finally, adopting a general parametrization of new physics contributions to the decay amplitudes, we discuss how to experimentally constrain new physics parameters.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Improved signal to noise ratio and sensitivity of an infrared imaging video bolometer on large helical device by using an infrared periscope

An Infrared imaging Video Bolometer (IRVB) diagnostic is currently being used in the Large Helical Device (LHD) for studying the localization of radiation structures near the magnetic island and helical divertor X-points during plasma detachment and for 3D tomography. This research demands high signal to noise ratio (SNR) and sensitivity to improve the temporal resolution for studying the evolution of radiation structures during plasma detachment and a wide IRVB field of view (FoV) for tomography. Introduction of an infrared periscope allows achievement of a higher SNR and higher sensitivity, which in turn, permits a twofold improvement in the temporal resolution of the diagnostic. Higher SNR along with wide FoV is achieved simultaneously by reducing the separation of the IRVB detector (metal foil) from the bolometer's aperture and the LHD plasma. Altering the distances to meet the aforesaid requirements results in an increased separation between the foil and the IR camera. This leads to a degradation of the diagnostic performance in terms of its sensitivity by 1.5-fold. Using an infrared periscope to image the IRVB foil results in a 7.5-fold increase in the number of IR camera pixels imaging the foil. This improves the IRVB sensitivity which depends on the square root of the number of IR camera pixels being averaged per bolometer channel. Despite the slower f-number (f/# = 1.35) and reduced transmission (τ{sub 0} = 89%, due to an increased number of lens elements) for the periscope, the diagnostic with an infrared periscope operational on LHD has improved in terms of sensitivity and SNR by a factor of 1.4 and 4.5, respectively, as compared to the original diagnostic without a periscope (i.e., IRVB foil being directly imaged by the IR camera through conventional optics). The bolometer's field of view has also increased by two times. The paper discusses these improvements in apt details.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Transmembrane transport of peptide type compounds: prospects for oral delivery

Synthesis and delivery of potential therapeutic peptides and peptidomimetic compounds has been the focus of intense research over the last 10 years. While it is widely recognized that numerous limitations apply to oral delivery of peptides, some of the limiting factors have been addressed and their mechanisms elucidated, which has lead to promising strategies. This article will briefly summarize the challenges, results and current approaches of oral peptide delivery and give some insight on future strategies. The barriers determining peptide bioavailability after oral administration are intestinal membrane permability, size limitations, intestinal and hepatic metabolism and in some cases solubility limitations. Poor membrane permeabilities of hydrophilic peptides might be overcome by structurally modifying the compounds, thus increasing their membrane partition characteristics and/or their affinity to carrier proteins. Another approach is the site-specific delivery of the peptide to the most permeable parts of the intestine. The current view on size limitation for oral drug delivery has neglected partition considerations. Recent studies suggest that compounds with a molecular weight up to 4000 might be significantly absorbed, assuming appropriate partition behavior and stability. Metabolism, probably the most significant factor in the absorption fate of peptides, might be controlled by coadministration of competitive enzyme inhibitors, structural modifications and administration of the compound as a well absorbed prodrug that is converted into the therapeutically active agent after its absorption. For some peptides poor solubility might present a limitation to oral absorption, an issue that has been addressed by mechanistically defining and therefore improving formulation parameters. Effective oral peptide delivery requires further development in understanding these complex mechanisms in order to maximize the therapeutic potential of this class of compounds.

NASA Discipline Regulatory Physiology↗

Development of a novel depth of interaction PET detector using highly multiplexed G-APD cross-strip encoding

Purpose: The aim of this study was to develop a prototype PET detector module for a combined small animal positron emission tomography and magnetic resonance imaging (PET/MRI) system. The most important factor for small animal imaging applications is the detection sensitivity of the PET camera, which can be optimized by utilizing longer scintillation crystals. At the same time, small animal PET systems must yield a high spatial resolution. The measured object is very close to the PET detector because the bore diameter of a high field animal MR scanner is limited. When used in combination with long scintillation crystals, these small-bore PET systems generate parallax errors that ultimately lead to a decreased spatial resolution. Thus, we developed a depth of interaction (DoI) encoding PET detector module that has a uniform spatial resolution across the whole field of view (FOV), high detection sensitivity, compactness, and insensitivity to magnetic fields. Methods: The approach was based on Geiger mode avalanche photodiode (G-APD) detectors with cross-strip encoding. The number of readout channels was reduced by a factor of 36 for the chosen block elements. Two 12 × 2 G-APD strip arrays (25μm cells) were placed perpendicular on each face of a 12 × 12 lutetium oxyorthosilicate crystal block with a crystal size of 1.55 × 1.55 × 20 mm. The strip arrays were multiplexed into two channels and used to calculate the x, y coordinates for each array and the deposited energy. The DoI was measured in step sizes of 1.8 mm by a collimated {sup 18}F source. The coincident resolved time (CRT) was analyzed at all DoI positions by acquiring the waveform for each event and applying a digital leading edge discriminator. Results: All 144 crystals were well resolved in the crystal flood map. The average full width half maximum (FWHM) energy resolution of the detector was 12.8% ± 1.5% with a FWHM CRT of 1.14 ± 0.02 ns. The average FWHM DoI resolution over 12 crystals was 2.90 ± 0.15 mm. Conclusions: The novel DoI PET detector, which is based on strip G-APD arrays, yielded a DoI resolution of 2.9 mm and excellent timing and energy resolution. Its high multiplexing factor reduces the number of electronic channels. Thus, this cross-strip approach enables low-cost, high-performance PET detectors for dedicated small animal PET and PET/MRI and potentially clinical PET/MRI systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Star-Viewing Scheduler

Strategy and algorithm produce well-balanced timetable that accommodates many constraints. Strategy for scheduling star observations on Space Shuttle astronomy missions ensures best use of three future ultraviolet telescopes. Strategy, described in report, takes into account such diverse factors as maneuvers of Space Shuttle orbiter, interference by Moon, occultation by Earth, reflections, unstaffed periods during crew rotation, encounters with South Atlantic anomaly, and obscuration during dispersal of ejected water.

Guffin, O. T.↗

Human factors of advanced technology (glass cockpit) transport aircraft

A three-year study of airline crews at two U.S. airlines who were flying an advanced technology aircraft, the Boeing 757 is discussed. The opinions and experiences of these pilots as they view the advanced, automated features of this aircraft, and contrast them with previous models they have flown are discussed. Training for advanced automation; (2) cockpit errors and error reduction; (3) management of cockpit workload; and (4) general attitudes toward cockpit automation are emphasized. The limitations of the air traffic control (ATC) system on the ability to utilize the advanced features of the new aircraft are discussed. In general the pilots are enthusiastic about flying an advanced technology aircraft, but they express mixed feelings about the impact of automation on workload, crew errors, and ability to manage the flight.

Wiener, Earl L.↗