Search NASA⌕ Search

SEARCH · Search NASA

Results for “Accelerators, Instrumentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

ATLAS toward the High Luminosity era: challenges on electronic systems

To maximize the physics reach, the Large Hadron Collider (LHC) plans to increase its instantaneous luminosity to $7.5×10^{34} cm^{-2} s^{-1}$ and deliver $3 - 4 ab^{-1}$ of data at a center-of-mass energy of 14 TeV. To profit from this high-luminosity LHC operation with a pile-up up to 200 inelastic collisions per bunch crossing, performance of the ATLAS detector needs to be maintained and in many systems, improved. The upgraded detector will have an unprecedented output data rate of up to 200 TB/s. Real-time processing of this large data volume in a short time period is extremely challenging. New sets of both front-end and back-end electronics are required for all sub-detectors. The large number of detector channels, huge volumes of input and output data, short time available to process and transmit data, harsh radiation environment, and the need of low power consumption all impose great challenges on the designs of electronic systems.

43 PARTICLE ACCELERATORS↗

Radiation Effects of n-type, Low Resistivity, Spiral Silicon Drift Detector Hybrid Systems

We have developed a new thin-window, n-type, low-resistivity, spiral silicon drift detector (SDD) array - to be used as an extraterrestrial X-ray spectrometer (in varying environments) for NASA. To achieve low-energy response, a thin SDD entrance window was produced using a previously developed method. These thin-window devices were also produced on lower resistivity, thinner, n-type, silicon material, effectively ensuring their radiation hardness in anticipation of operation in potentially harsh radiation environments (such as found around the Jupiter system). Using the Indiana University Cyclotron Facility beam line RERS1, we irradiated a set of suitable diodes up to 5 Mrad and the latest iteration of our ASICs up to 12 Mrad. Then we irradiated two hybrid detectors consisting of newly, such-produced in-house (BNL) SDD chips bonded with ASICs with doses of 0.25 Mrad and 1 Mrad. Also we irradiated another hybrid detector consisting of previously produced (by KETEK) on n-type, high-resistivity SDD chip bonded with BNL's ASICs with a dose of 1 Mrad. The measurement results of radiated diodes (up to 5 Mrad), ASICs (up to 12 Mrad) and hybrid detectors (up to 1 Mrad) are presented here.

43 PARTICLE ACCELERATORS↗

Tolerance Studies of the Mu2e Solenoid System

The muon-to-electron conversion experiment at Fermilab is designed to explore charged lepton flavor violation. It is composed of three large superconducting solenoids, namely, the production solenoid, the transport solenoid, and the detector solenoid. Each subsystem has a set of field requirements. Tolerance sensitivity studies of the magnet system were performed with the objective of demonstrating that the present magnet design meets all the field requirements. Systematic and random errors were considered on the position and alignment of the coils. The study helps to identify the critical sources of errors and which are translated to coil manufacturing and mechanical support tolerances.

43 PARTICLE ACCELERATORS↗

Studies on the Magnetic Center of the Mu2e Solenoid System

The definition of the magnetic center in the Mu2e solenoid system is not trivial given the S-shaped nature of the transport solenoid. Moreover, due to the fringe field of the larger bore adjacent magnets-production solenoid and the detector solenoid-the magnetic center does not coincide with the geometric center of the system. The reference magnetic center can be obtained by tracking a low-momentum charged particle through the whole system. This paper will discuss this method and will evaluate the deviations from the nominal magnetic center given the tolerances in the manufacturing and the alignment of the coils. Methods for the correction of the magnetic center will also be presented.

43 PARTICLE ACCELERATORS↗

Torus CLAS12-Superconducting Magnet Quench Analysis

The JLAB Torus magnet system consists of six superconducting trapezoidal racetrack-type coils assembled in a toroidal configuration. These coils are wound with SSC-36 Nb-Ti superconductor and have the peak magnetic field of 3.6 T. The first coil manufacturing based on the JLAB design began at FNAL. The large magnet system dimensions (8 m diameter and 14 MJ of stored energy) dictate the need for quench protection. Each coil is placed in an aluminum case mounted inside a cryostat and cooled by 4.6 K supercritical helium gas flowing through a copper tube attached to the coil ID. The large coil dimensions and small cryostat thickness drove the design to challenging technical solutions, suggesting that Lorentz forces due to transport currents and eddy currents during quench and various failure scenarios are analyzed. The paper covers the magnet system quench analysis using the OPERA3d Quench code.

Kashikhin, V S↗

Applied metrology in the production of superconducting model magnets for particle accelerators

The production of superconducting magnets for particle accelerators involves high precision assemblies and tight tolerances, in order to achieve the requirements for their appropriate performance. It is therefore essential to have a strict control and traceability over the geometry of each component of the system, and also to be able to compensate possible inherent deviations coming from the production process.

43 PARTICLE ACCELERATORS↗

Beam test measurements with planar and 3D silicon strip detectors irradiated to sLHC fluences

The planned luminosity upgrade of the CERN LHC to the super LHC (sLHC) requires investigation of new radiation hard tracking detectors. Compared to the LHC, tracking detectors must withstand a 5-10 times higher radiation fluence. Promising radiation hard options are planar silicon detectors with n-side readout and silicon detectors in 3D technology, where columnar electrodes are etched into the silicon substrate. This article presents beam test measurements per formed with planar and 3D n-in-p silicon strip detectors. The detectors were irradiated to different fluences, where the maximum fluence was 3 x 10{sup 15} 1 MeV neutron equivalent particles per square centimeter (n{sub eq}/cm{sup 2}) for the planar detectors and 2 x 10{sup 15} n{sub eq}/cm{sup 2} for the 3D detectors. In addition to signal measurements, charge sharing and resolution of both detector technologies are compared. An increased signal from the irradiated 3D detectors at high bias voltages compared to the signal from the unirradiated detector indicates that charge multiplication effects occur in the 3D detectors. At a bias voltage of 260 V, the 3D detector irradiated to 2 x 10{sup 15} n{sub eq}/cm{sup 2} yields a signal almost twice as high as the signal of the unirradiated detector. Only 30% of the signal of an unirradiated detector could be measured with the planar detector irradiated to 3 x 10{sup 15} n{sub eq}/cm{sup 2} at a bias voltage of 600 V, which was the highest bias voltage applied to this sensor.

43 PARTICLE ACCELERATORS↗

A Spin-Light Polarimeter for Multi-GeV Longitudinally Polarized Electron Beams

The physics program at the upgraded Jefferson Lab (JLab) and the physics program envisioned for the proposed electron-ion collider (EIC) include large efforts to search for interactions beyond the Standard Model (SM) using parity violation in electroweak interactions. These experiments need precision electron polarimetry with an uncertainty of <; 0.5 %. The spin dependent Synchrotron radiation, called "spin-light," can be used to monitor the electron beam polarization. Here, we develop a conceptual design for a "spin-light" polarimeter that can be used at a high intensity, multi-GeV electron accelerator. We have also built a Geant4 based simulation for a prototype device and report some of the results from these simulations

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Cadmium Magnesium Telluride for Next-Generation X-Ray Free Electron Laser, Synchrotron, and Many Other Applications

We developed a picosecond photodetector based on our Bridgman-grown and specially engineered cadmium magnesium telluride (Cd 1–x MgxTe) single crystal that is sensitive to both optical and X-ray pulses for coarse timing in free-electron laser applications. Cd 1–x MgxTe is a widebandgap semiconductor with potential applications, not only in optoelectronics, but also in particle physics as an intense pulse radiation detector for bremsstrahlung, X-ray/gamma-ray radiation, thermal neutrons, and medical imaging. For femtosecond optical and X-ray crosscorrelation, the material must have a very short lifetime, a condition that is opposite to that required for nuclear spectroscopy applications. At the same time, the material also needs to have a very low bulk leakage current, in the 10–90 nA range for voltages to even 1000 V. Hence, the ability to tailor or engineer the material is very crucial. Picosecond response and the crystal growth of this specially engineered Cd 1–x MgxTe material are presented. Furthermore, other characterization and transient measurements are discussed along with room-temperature semiconductor detector performance for other nuclear radiation detection applications.

36 MATERIALS SCIENCE↗

Time Resolution Characterization of 4H-SiC LGADs with a 90 Sr Source

This work presents timing measurements of 4H-SiC Low Gain Avalanche Detectors (4H-SiC LGADs) using beta particles from a 90Sr source. The 4H-SiC LGADs exhibit fast signal responses, and a time resolution of 61 ps was achieved, comparable to that of standard Si LGADs. The present limitation in the time resolution of 4H-SiC LGADs appears to stem from limited charge generation. Nevertheless, their higher voltage tolerance and faster carrier drift suggest that, with increased charge collection, their timing performance could approach or even surpass that of Si LGADs. Furthermore, these results demonstrate the strong potential of 4H-SiC LGADs as a robust platform for precision timing in future 4D tracking detectors, while also highlighting that signal charge is the dominant factor currently limiting their performance, indicating that further optimization of gain and drift structures will be essential for future development.

43 PARTICLE ACCELERATORS↗

Activator-doped Hg 2 Br 2 as next generation high performance scintillator for high energy physics research and other scientific and imaging applications

Existing COTS inorganic scintillators all have the characteristic of being very good at certain desirable properties, but not sufficient at other desirable properties for HEP. The demand for suitable scintillators (with regards to both scintillation detector properties and suitable pricing), to be used for modern intensities frontier (Mu2e-II), energy frontier (High luminosity large hadron collider) and future e+e- collider projects (aimed as Higgs bosons factory, such as the International Linear Collider (ILC) and the Future Circular Collider (FCC) are putting even higher challenges on crystal scintillators.In this work, we report the development of a novel high-performance scintillators that can address the issues associated with existing scintillators, the activator doped Hg2Br2. Initial results are very encouraging on the detection of gamma and alpha particles using a solid-state photomultiplier (SSPM). The responses have been stable and repeatable. Hg2Br2 also has many advantages over existing COTS scintillators such as: high density, bright, fast, good energy resolution, no intrinsic radiation, radiation hard and cost-effectiveness. Here, we present here why Hg2Br2 is the next generation scintillator for high energy physics experiments as well as other scientific and imaging applications such as planetary science and medical imaging.

36 MATERIALS SCIENCE↗

Status of the endcap BGO calorimeter of the CMD-3 detector

The electromagnetic endcap BGO calorimeter of the CMD-3 detector is ready for experiments at the new e{sup +}e{sup -} collider VEPP-2000. Light readout is performed by silicon photodiodes. A thermalcontrol system that is able to maintain the calorimeter temperature at a level of 12 {+-}1 deg. C was designed and manufactured. All blocks of the endcap calorimeter are assembled, tested, and prepared for installing at the detector.

43 PARTICLE ACCELERATORS↗

Future particle-physics projects in the United States

Here, basic proposals of experiments aimed at precision measurements of Standard Model parameters and at searches for new particles, including dark-matter particles, are described along with future experimental projects considered by American Physical Society at the meeting in the summer of 2013 and intended for implementation within the next ten to twenty years.

43 PARTICLE ACCELERATORS↗

Application of cyclotrons in beam technologies

Some currently developed applications of cyclotrons (beam technologies) are discussed. They include new methods for producing radioisotopes for medical purposes and investigations into the radiation strength ofmaterials and the wear of units of variousmachines and devices bymeans of beams of radioactive nuclei.

43 PARTICLE ACCELERATORS↗

Feasibility of the Precise Energy Calibration for Fast Neutron Spectrometers

Computational studies aimed at improving the accuracy of measurements performed using neutron generators with a tritium target were performed. A measurement design yielding an extremely narrow peak in the energy spectrum of DT neutrons was found. The presence of such a peak establishes the conditions for precise energy calibration of fast-neutron spectrometers.

43 PARTICLE ACCELERATORS↗

Efficiency Of Charged-Particle Detection with Scintillation-Detector Prototype for the Anticoincidence System of the Signal Experiment

The results obtained by measuring the efficiency of detection of charged particles (atmospheric muons) for a prototype of a polyvinyltoluene-based scintillation detector being created for the anticoincidence system of the Signal experiment on board the Interhelioprobe spacecraft are presented. These measurements rely on determining the ratio of the numbers of triple and double coincidences of pulses that arise as atmospheric muons traverse the detector system.

43 PARTICLE ACCELERATORS↗

Conical Mirror Energy-Analyzer

Electron optical properties of an axisymmetric mirror energy-analyzer are studied. The internal electrode represents a cylinder, and the external electrode is formed by two identical cones with common bases. It is shown that the relative aperture and resolution of such an analyzer are significantly greater than the corresponding parameters of a conventional cylindrical mirror. The internal electrode is made of three cylinders with different diameters, and the potentials of the cylinders are identical. Such a structure is used to further improve electron optical characteristics of the conical analyzer. At a relatively small beam angle, the resolution of the conical analyzer is two times greater than the resolution of the cylindrical mirror, and the difference of the resolutions amounts to an order of magnitude when the beam angle increases.

43 PARTICLE ACCELERATORS↗

The ATLAS Inner Detector commissioning and calibration

The ATLAS Inner Detector is a composite tracking system consisting of silicon pixels, silicon strips and straw tubes in a 2 T magnetic field. Its installation was completed in August 2008 and the detector took part in data-taking with single LHC beams and cosmic rays. The initial detector operation, hardware commissioning and in-situ calibrations are described. Tracking performance has been measured with 7. 6 million cosmic-ray events, collected using a tracking trigger and reconstructed with modular pattern-recognition and fitting software. The intrinsic hit efficiency and tracking trigger efficiencies are close to 100%. Lorentz angle measurements for both electrons and holes, specific energy-loss calibration and transition radiation turn-on measurements have been performed. Different alignment techniques have been used to reconstruct the detector geometry. After the initial alignment, a transverse impact parameter resolution of 22.1±0.9 μm and a relative momentum resolution σ p /p=(4. 83 ± 0.16)×10 -4 GeV -1 ×p T have been measured for high momentum tracks.

43 PARTICLE ACCELERATORS↗