Search NASA⌕ Search

SEARCH · Search NASA

Results for “Advanced Diagnostics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Plant Disease Detection Technology Assessment

Visual inspections by US Customs and Border Protection agriculture specialists have identified approximately 20,000 regulated, quarantined pests each year in agricultural products entering the United States. Most of these pests identified in the Agriculture Quarantine and Inspection (AQI) program are insects. Many pathogens are difficult to detect in agricultural products, particularly in early stages of infection. New technologies can help to detect plant pathogens and the diseases that they cause. This technology assessment was performed for the US Department of Homeland Security Science and Technology Directorate (DHS S&T) through the Food, Agriculture, and Veterinary Defense (FAV-D) program to identify emerging technologies that could address this hard problem. These emerging technologies differ in their diagnostic sensitivities and specificities, as well as in their measurement time and training requirements. New instruments that detect volatile organic compounds characteristic of plant disease or pathogens could provide a less invasive inspection method. Dogs, which can successfully detect many concealed agricultural products, have also been trained to detect some plant pests and pathogens. Simple immunological tests offer sensitive and specific detection of many pathogens at the point of use. Advanced imaging methods that use AI to sort fruits and vegetables and recognize anomalies at high speeds could be used in cooperation with exporters to improve food quality and reduce pests. Advances in nucleic acid–based detection methods that have become gold standards for confirmatory diagnostics are now making those methods available for faster, point-of-use detection. These new methods should be developed in the context of AQI operational requirements, which apply risk-based sampling protocols to protect agriculture and facilitate commerce and passenger transit.

59 BASIC BIOLOGICAL SCIENCES↗

Microscale and Nanoscale Electrophotonic Diagnostic Devices

Detecting and identifying infectious agents and potential pathogens in complex environments and characterizing their mode of action is a critical need. Traditional diagnostics have targeted a single characteristic, e.g. spectral response, surface receptor, mass, intrinsic conductivity, etc. However, advances in detection technologies have identified emerging approaches in which multiple modes of action are combined to obtain enhanced performance characteristics. Particularly appealing in this regard, electrophotonic devices capable of coupling light to electron translocation have experienced rapid recent growth and offer significant advantages for diagnostics. In this chapter, we explore three specific promising approaches that combine electronics and photonics: (a) assays based on closed bipolar electrochemistry coupling electron transfer to color or fluorescence (b) sensors based on localized surface plasmon resonances, and (c) emerging nanophotonics approaches, such as those based on zero-mode waveguides and metamaterials.

60 APPLIED LIFE SCIENCES↗

Rocket engine exhaust plume diagnostics and health monitoring/management during ground testing

The current status of a rocket exhaust plume diagnostics program sponsored by NASA is reviewed. The near-term objective of the program is to enhance test operation efficiency and to provide for safe cutoff of rocket engines prior to incipient failure, thereby avoiding the destruction of the engine and the test complex and preventing delays in the national space program. NASA programs that will benefit from the nonintrusive remote sensed rocket plume diagnostics and related vehicle health management and nonintrusive measurement program are Space Shuttle Main Engine, National Launch System, National Aero-Space Plane, Space Exploration Initiative, Advanced Solid Rocket Motor, and Space Station Freedom. The role of emission spectrometry and other types of remote sensing in rocket plume diagnostics is discussed.

Chenevert, D. J.↗

Novel imaging techniques of rectal cancer: what do radiomics and radiogenomics have to offer? A literature review

Introduction: As computational capabilities have advanced, radiologists and their collaborators have looked for novel ways to analyze diagnostic images. This has resulted in the development of radiomics and radiogenomics as new fields in medical imaging. Radiomics and radiogenomics may change the practice of medicine, particularly for patients with colorectal cancer. Radiomics corresponds to the extraction and analysis of numerous quantitative imaging features from conventional imaging modalities in correlation with several endpoints, including the prediction of pathology, genomics, therapeutic response, and clinical outcome. In radiogenomics, qualitative and/or quantitative imaging features are extracted and correlated with genetic profiles of the imaged tissue. Thus far, several studies have evaluated the use of radiomics and radiogenomics in patients with colorectal cancer; however, there are challenges to be overcome before its routine implementation including challenges related to sample size, model design and interpretability, and the lack of robust multicenter validation set. Material and methods: In this article, we will review the concepts of radiomics and radiogenomics and their potential applications in rectal cancer. Conclusion: Radiologists should be aware of the basic concepts, benefits, pitfalls, and limitations of new radiomic and radiogenomics techniques to achieve a balanced interpretation of the results.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Can Positron Emission Tomography (PET) or PET/Computed Tomography (CT) Acquired in a Nontreatment Position Be Accurately Registered to a Head-and-Neck Radiotherapy Planning CT?

Purpose: To quantify the uncertainties associated with incorporating diagnostic positron emission tomography/CT (PET/CT) and PET into the radiotherapy treatment-planning process using different image registration tools, including automated and manual rigid body registration methods, as well as deformable image registration. Methods and Materials: The PET/CTs and treatment-planning CTs from 12 patients were used to evaluate image registration accuracy. The PET/CTs also were used without the contemporaneously acquired CTs to evaluate the registration accuracy of stand-alone PET. Registration accuracy for relevant normal structures was quantified using an overlap index and differences in the center of mass (COM) positions. For tumor volumes, the registration accuracy was measured using COM positions only. Results: Registration accuracy was better with PET/CT than with PET alone. The COM displacements ranged from 3.2 {+-} 0.6 mm (mean {+-} 95% confidence interval, for brain) to 8.4 {+-} 2.6 mm (spinal cord) for registration with PET/CT data, compared with 4.8 {+-} 1.7 mm (brain) and 9.9 {+-} 3.1 mm (spinal cord) with PET alone. Deformable registration improved accuracy, with minimum and maximum errors of 1.1 {+-} 0.8 mm (brain) and 5.4 {+-} 1.4 mm (mandible), respectively. Conclusions: It is possible to incorporate PET and/or PET/CT acquired in diagnostic positions into the treatment-planning process through the use of advanced image registration algorithms, but precautions must be taken, particularly when delineating tumor volumes in the neck. Acquisition of PET/CT in the treatment-planning position would be the ideal method to minimize registration errors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison of the Optical Connectivity Method to X-Ray spray measurements in the near field of a diesel injector

For diesel sprays, the primary breakup processes are only rarely understood due to the high optical density and the resulting difficulties to measure them with extremely high spatial and sufficient temporal resolution. The Optical Connectivity Method (OCM) has been proposed in the last years to allow the determination of the breakup length of the connected liquid core, thus giving a measurement quantity of the primary breakup. In this research, an improved optical setup of the OCM is applied to a three-hole test injector nozzle where several measurement techniques are compared currently under well-defined conditions up to 100 MPa injection pressure. In this work, the direct comparison with X-Ray measurements done at the Advanced Photon Source of the Argonne National Laboratory will be described. This allows an evaluation of the OCM technique and a comparison of the different measurement quantities in the first 500 μm range of the spray. The structure of the spray is measured by X-Ray phase contrast imaging and the fuel mass distribution is measured by X-Ray absorption imaging. A detailed comparison of the two X-Ray techniques and the OCM technique has been possible for the first time. It is found that the measurement data of the spray near field are very congruent with all three methods. Due to this comparison, the measurement of the non-perturbed length, which describes the distance from the nozzle orifice up to the point where the formation of surface disturbances is starting, by the OCM is validated for the first time. Within this non-perturbed length of the spray, the OCM signal is weak before it starts to illuminate from the scattering of the perturbed surface. Hence, the OCM technique can deliver two characteristic length scales, the non-perturbed length and the breakup length , characterizing the primary spray breakup.

33 ADVANCED PROPULSION SYSTEMS↗

A new calibration code for the JET polarimeter

An equivalent model of JET polarimeter is presented, which overcomes the drawbacks of previous versions of the fitting procedures used to provide calibrated results. First of all the signal processing electronics has been simulated, to confirm that it is still working within the original specifications. Then the effective optical path of both the vertical and lateral chords has been implemented to produce the calibration curves. The principle approach to the model has allowed obtaining a unique procedure which can be applied to any manual calibration and remains constant until the following one. The optical model of the chords is then applied to derive the plasma measurements. The results are in good agreement with the estimates of the most advanced full wave propagation code available and have been benchmarked with other diagnostics. The devised procedure has proved to work properly also for the most recent campaigns and high current experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Converting existing optical detectors into fast x-ray detectors

Here, the very short burn time and small size of burning plasmas created at advanced laser-fusion facilities will require high-spatial-resolution imaging diagnostics with fast time resolution. These instruments will need to function in an environment of extremely large neutron fluxes that will cause conventional diagnostics to fail because of radiation damage and induced background levels. One solution to this challenge is to perform an ultrafast conversion of the x-ray signals into the optical regime before the neutrons are able to reach the detector and then to relay image the signal out of the chamber and into a shielded bunker, protected from the effects of these neutrons. With this goal in mind, the OMEGA laser was used to demonstrate high-temporal-resolution x-ray imaging by using an x-ray snout to image an imploding backlighter capsule onto a semiconductor. The semiconductor was simultaneously probed with the existing velocity interferometry system for any surface reflector (VISAR) diagnostic, which uses an optical streak camera and provided a one-dimensional image of the phase in the semiconductor as a function of time. The phase induced in the semiconductor was linearly proportional to the x-ray emission from the backlighter capsule. This approach would then allow a sacrificial semiconductor to be attached at the end of an optical train with the VISAR and optical streak camera placed in a shielded bunker to operate in a high neutron environment and obtain time-dependent one-dimensional x-ray images or time-dependent x-ray spectra from a burning plasma.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Electromagnetic Pulses at Short-Pulse Laser Facilities

Electromagnetic Pulse (EMP) is a known issue for short-pulse laser facilities, and will also be an issue for experiments using the advanced radiographic capability (ARC) at the National Ignition Facility (NIF). The ARC diagnostic uses four NIF beams that are compressed to picosecond durations for backlighting ignition capsules and other applications. Consequently, we are working to understand the EMP due to high-energy (MeV) electrons escaping from targets heated by short-pulse lasers. Our approach is to measure EMP in the Titan short-pulse laser at Lawrence Livermore National Laboratory (LLNL) and to employ that data to establish analysis and simulation capabilities. We have installed a wide variety of probes inside and outside the Titan laser chamber. We have high-frequency B-dot and D-dot probes, a photodiode, and fast current-viewing and integrating current transformers. The probe outputs are digitized by 10 and 20 Gsample/s oscilloscopes. The cables and oscilloscopes are well shielded to reduce noise. Our initial measurement campaign has yielded data useful mainly from several hundreds of MHz to several GHz. We currently are supplementing our high-frequency probes with lower-frequency ones to obtain better low-frequency data. In order to establish analysis and simulation capabilities we are modeling the Titan facility using various commercial and LLNL numerical electromagnetics codes. We have simulated EMP generation by having a specified number of electrons leave the target and strike the chamber wall and other components in the chamber. This short impulse of electrons has a correspondingly broad spectrum, exciting high-frequency structure in the resulting EMP. In this paper, we present results of our initial measurement campaign and comparisons between the measurements and simulations.

36 MATERIALS SCIENCE↗

The Monarch Initiative: an integrative data and analytic platform connecting phenotypes to genotypes across species

The correlation of phenotypic outcomes with genetic variation and environmental factors is a core pursuit in biology and biomedicine. Numerous challenges impede our progress: patient phenotypes may not match known diseases, candidate variants may be in genes that have not been characterized, model organisms may not recapitulate human or veterinary diseases, filling evolutionary gaps is difficult, and many resources must be queried to find potentially significant genotype-phenotype associations. Nonhuman organisms have proven instrumental in revealing biological mechanisms. Advanced informatics tools can identify phenotypically relevant disease models in research and diagnostic contexts. Large-scale integration of model organism and clinical research data can provide a breadth of knowledge not available from individual sources and can provide contextualization of data back to these sources. The Monarch Initiative (monarchinitiative.org) is a collaborative, open science effort that aims to semantically integrate genotype-phenotype data from many species and sources in order to support precision medicine, disease modeling, and mechanistic exploration. Our integrated knowledge graph, analytic tools, and web services enable diverse users to explore relationships between phenotypes and genotypes across species.

59 BASIC BIOLOGICAL SCIENCES↗

Advanced transport aircraft technology

Various elements of the NASA aircraft energy efficiency program are described. Regarding composite structures, the development of three secondary and three medium-primary components to validate structural and fabrication technology is discussed. In laminar flow control, the design of advanced airfoils having large regions of supercritical flow with features which simplify laminarization are considered. Emphasis is placed on engine performance improvement, directed at developing advanced components to reduce fuel consumption in current production engines, and engine diagnostics aimed at identifying the sources and causes of performance deterioration in high-bypass turbofan engines. In addition, the results of propeller aerodynamic and acoustic tests have substantiated the feasibility of achieving the propeller efficiency goal of 80% and confirmed that the effect of blade sweep on reducing propeller source noise was 5-6 dB.

Winblade, R. L.↗

Reusable Rocket Engine Maintenance Study

Approximately 85,000 liquid rocket engine failure reports, obtained from 30 years of developing and delivering major pump feed engines, were reviewed and screened and reduced to 1771. These were categorized into 16 different failure modes. Failure propagation diagrams were established. The state of the art of engine condition monitoring for in-flight sensors and between flight inspection technology was determined. For the 16 failure modes, the potential measurands and diagnostic requirements were identified, assessed and ranked. Eight areas are identified requiring advanced technology development.

Macgregor, C. A.↗

Acoustic emission monitoring of SSME-ATD roller bearings

Advanced acoustic emission (AE) monitoring methods are being designed to provide a diagnostic capability for ball and roller bearings as part of a program to develop AE sensors, data acquisition hardware, and analysis techniques that can be used to assess the health of a bearing during the operation of the SSME high pressure fuel turbopump and high pressure oxygen turbopump. Preliminary results are presented from six tests of different roller bearing designs in a rig which simulated the speed, load, and temperature environment encountered in the turbopumps. Correlations were found between the bearing clearances, applied loads, rotation speeds, and roller element stability with the AE signal structure.

Hawman, M. W.↗

Dynamics of cometary dust

This paper summarizes recent progress in our understanding of the morphological diversity of dust comets. This diversity is a product of dust emission from discrete active areas on the nucleus surface and provides information on the comet's rotation state and source function. Advances in computer simulations of dust coma morphology are described and the diagnostic properties of various dusty features are emphasized. Also addressed are some of the issues of dust tail morphology and particle fragmentation. Finally, lessons learnt from investigations of the dust population of comet Shoemaker-Levy 9 are discussed and implications for physical studies of the comet's collision with Jupiter are identified.

comets↗

Relating Lightning Flash Characteristics to Convective Structure in Tropical Cyclones

For decades, lightning has been used with some success as an indicator of tropical cyclone (TC) intensity change. An increase in inner-core lightning is usually associated with TC intensification, but this is not always the case. Significant lightning outbreaks have been observed in weakening storms, and hurricanes can rapidly intensify in the total absence of inner-core lightning. These conflicting results arise because lightning production depends on convective and microphysical characteristics that can arise during both intensification and weakening phases in TCs. Recent work using flash size and energy metrics provided by the Geostationary Lightning Mapper (GLM) aboard the GOES-R series of satellites shows some promise in distinguishing between lightning outbreaks that correspond to intensification and those that correspond to weakening. If a hurricane is rapidly intensifying in the presence of inner-core lightning, the size and optical energy of the flashes generally increases as intensification proceeds. It is hypothesized that this relationship is governed by changes in the TC-scale circulation that produce enhanced upper-level outflow and large, strongly helical convective updrafts in the inner core. These changes increase the quantity and spatial extent of charged upper-level ice, which allows large intracloud flashes to occur when electric field breakdown occurs. This presentation will present objective diagnostics of convective asymmetry using azimuthal wavenumber decomposition of GOES-R Advanced Baseline Imager brightness temperatures. The degree of symmetry will be related to GLM flash characteristics to better understand how changes in the symmetry of TC inner-core convection relates to flash rate, size, and energy. It will also show how the evolution of inner-core asymmetries relates to the spatial distribution and characteristics of lightning flashes in the inner core.

Patrick Duran↗

Advanced Concept Exploration for Fast Ignition Science Program (Final Report)

The Fast Ignition (FI) Concept for Inertial Confinement Fusion (ICF) has the potential to provide a significant advance in the technical attractiveness of Inertial Fusion Energy reactors. FI differs from conventional “central hot spot” (CHS) target ignition by decoupling compression from heating: using a laser (or heavy ion beam or Z pinch) drive pulse (10’s of nanoseconds) to create a dense fuel and a second, much shorter (~10 picoseconds) high intensity pulse to ignite a small volume within the dense fuel. The physics of fast ignition process was the focus of our Advanced Concept Exploration (ACE) program. Ignition depends critically on two major issues involving Relativistic High Energy Density (RHED) physics: The laser-induced creation of fast electrons and their propagation in high-density plasmas. Our program has developed new experimental platforms, diagnostic packages, computer modeling analyses, and taken advantage of the increasing energy available at laser facilities to advance understanding of the fundamental physics underlying these issues.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Understanding reliability and some limitations of the images and spectra reconstructed from a multi-monochromatic x-ray imager

Temperature and density asymmetry diagnosis is critical to advance inertial confinement fusion (ICF) science. A multi-monochromatic x-ray imager (MMI) is an attractive diagnostic for this purpose. The MMI records the spectral signature from an ICF implosion core with time resolution, 2-D space resolution, and spectral resolution. While narrow-band images and 2-D space-resolved spectra from the MMI data constrain temperature and density spatial structure of the core, the accuracy of the images and spectra depends not only on the quality of the MMI data but also on the reliability of the post-processing tools. In this paper, we synthetically quantify the accuracy of images and spectra reconstructed from MMI data. Errors in the reconstructed images are less than a few percent when the space-resolution effect is applied to the modeled images. The errors in the reconstructed 2-D space-resolved spectra are also less than a few percent except those for the peripheral regions. Spectra reconstructed for the peripheral regions have slightly but systematically lower intensities by ~6% due to the instrumental spatial-resolution effects. However, this does not alter the relative line ratios and widths and thus does not affect the temperature and density diagnostics. We also investigate the impact of the pinhole size variation on the extracted images and spectra. A 10% pinhole size variation could introduce spatial bias to the images and spectra of ~10%. A correction algorithm is developed, and it successfully reduces the errors to a few percent. Finally, it is desirable to perform similar synthetic investigations to fully understand the reliability and limitations of each MMI application.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗