Search NASA⌕ Search

SEARCH · Search NASA

Results for “Advanced Instrumentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Properties of Nb x Ti (1–x) N thin films deposited on 300 mm silicon wafers for upscaling superconducting digital circuits

Scaling superconducting digital circuits requires fundamental changes in the current material set and fabrication process. The transition to 300 mm wafers and the implementation of advanced lithography are instrumental in facilitating mature CMOS processes, ensuring uniformity, and optimizing the yield. Here, this study explores the properties of Nb x Ti (1–x) N films fabricated by magnetron DC sputtering on 300 mm Si wafers. As a promising alternative to traditional Nb in device manufacturing, Nb x Ti (1–x) N offers numerous advantages, including enhanced stability and scalability to smaller dimensions, in both processing and design. As a ternary material, Nb x Ti (1–x) N allows engineering material parameters by changing deposition conditions. The engineered properties can be used to modulate device parameters through the stack and mitigate failure modes. We report characterization of Nb x Ti (1–x) N films at less than 2% thickness variability, 2.4% T c variability and 3% composition variability. Film resistivity (140–375 Ωcm) shows a strong correlation with the film oxygen content, while the critical temperature T c (4.6 K–14.1 K) is strongly affected by film stoichiometry and its microstructure has only a moderate effect on modifying T c . Our results offer insights about the interplay between film stoichiometry, film microstructure and critical temperature.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

High-efficiency coherence-preserving harmonic rejection with crystal optics

This work reports a harmonic-rejection scheme based on the combination of Si(111) monochromator and Si(220) harmonic-rejection crystal optics. This approach is of importance to a wide range of X-ray applications in all three major branches of modern X-ray science (scattering, spectroscopy, imaging) based at major facilities, and especially relevant to the capabilities offered by the new diffraction-limited storage rings. It was demonstrated both theoretically and experimentally that, when used with a synchrotron undulator source over a broad range of X-ray energies of interest, the harmonic-rejection crystals transmit the incident harmonic X-rays on the order of 10 –6 . Considering the flux ratio of fundamental and harmonic X-rays in the incident beam, this scheme achieves a total flux ratio of harmonic radiation to fundamental radiation on the order of 10 –10 . The spatial coherence of the undulator beam is preserved in the transmitted fundamental radiation while the harmonic radiation is suppressed, making this scheme suitable not only for current third-generation synchrotron sources but also for the new diffraction-limited storage rings where coherence preservation is an even higher priority. Compared with conventional harmonic-rejection mirrors, where coherence is poorly preserved and harmonic rejection is less effective, this scheme has the added advantage of lower cost and footprint. Furthermore, this approach has been successfully utilized at the ultra-small-angle X-ray scattering instrument at the Advanced Photon Source for scattering, imaging and coherent X-ray photon correlation spectroscopy experiments. With minor modification, the harmonic rejection can be improved by a further five orders of magnitude, enabling even more performance capabilities.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Neutron scattering in the biological sciences: progress and prospects

The scattering of neutrons can be used to provide information on the structure and dynamics of biological systems on multiple length and time scales. Pursuant to a National Science Foundation-funded workshop in February 2018, recent developments in this field are reviewed here, as well as future prospects that can be expected given recent advances in sources, instrumentation and computational power and methods. Crystallography, solution scattering, dynamics, membranes, labeling and imaging are examined. For the extraction of maximum information, the incorporation of judicious specific deuterium labeling, the integration of several types of experiment, and interpretation using high-performance computer simulation models are often found to be particularly powerful.

59 BASIC BIOLOGICAL SCIENCES↗

Challenges for Interdiction of Nuclear Threats at Borders

Paper for the ANIMMA (International Conference on Advancements in Nuclear Instrumentation, Measurement Methods and their Applications) conference proceedings on the general topic of border screening.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Transitioning from Cobalt-60 to X-Ray or E-Beam for Medical Sterilization: Filling Data and Education Gaps

The Office of Radiological Security (ORS) within the U.S. DOE’s National Nuclear Security Administration (NNSA) is charged to “work with government, law enforcement, and businesses across the globe to protect radioactive sources used for medical, research, and commercial purposes; remove and dispose of disused radioactive sources; and reduce the global reliance on high activity radioactive sources through the promotion of viable non-radioisotopic alternative technologies.” In this effort, the NNSA/ORS, along with the Office of Defense Nuclear Nonproliferation R&D, has been working with government and private entities that utilize gamma-ray irradiators in areas that include blood irradiation, radiotherapy, biology research, well logging, and radiation processing to consider alternative technologies that do not depend upon radioactive materials. In the medical device industry, nearly 50% of products are sterilized with ethylene oxide, 40.5% with cobalt-60 gamma-rays, 4.5% with electron-beam (e-beam), and <1% with X-ray.(1,2) The cobalt-60 irradiation facilities use an estimated 150 MCi of isotope to sterilize approximately 200 million cubic feet of product annually.(3) Due to growing safety regulations governing cobalt-60 use, continued advancements in e-beam and X-ray accelerator technology, and the greater irradiation durations and costs for cobalt-60 irradiation compared to e-beam and X-ray, switching to these non-radionuclide modalities is increasingly economically competitive. However, this breakdown of 40.5% cobalt-60 and 5.5% accelerator for product sterilization illustrates the difficulty that market forces and industry players have had in overcoming barriers in transitioning to non-nuclide alternatives. Besides those associated with construction of new e-beam and X-ray facilities, significant financial and regulatory obstacles are also associated with the irradiation and comprehensive testing of product constituent polymers and elastomers. The standards associated with product material performance testing are the Association for the Advancement of Medical Instrumentation (AAMI) Technical Information Report 17 (TIR 17), and its referenced American Society for Testing and Materials (ASTM) polymer testing standards. In the study now underway, and the subject of this article, the NNSA/ORS provided R&D funding to the Pacific Northwest National Laboratory (PNNL) in partnership with university researchers, leading medical product manufacturers, accelerator manufacturers, and contract sterilizers. The resulting Team Nablo (in memory of Sam Nablo) includes individuals representing PNNL, Becton Dickinson (BD), Johnson & Johnson, Stryker, Texas A&M University (TAMU), Steri-Tek, Mevex, Ion Beam Applications (IBA), and Sterigenics. The goals of this study are to 1) Identify specific polymer and/or elastomer-based medical products that are currently sterilized with gamma-rays, and for which there are data gaps and would be of greatest industry impact, 2) Work with relevant ASTM subcommittees for guidance and for potential standard revision, 3) Work with an appropriate Food & Drug Administration (FDA) office for potential collaboration on a guidance document for device manufacturers, 4) Measure the physical effects that product materials exhibit when they are given sterilization-level radiation doses from cobalt-60, e-beam or X-ray, and determine whether these effects would preclude the use of e-beam or X-ray for sterilization, 5) Communicate the resulting scientific datasets and findings via industry conferences, peer-reviewed journals, and relevant trade magazines, and 6) Post the resulting datasets on a publicly accessible website, which can be built on in future years. The end objective is to identify technical barriers preventing the adoption of X-ray and e-beam technologies, and share the results to encourage X-ray and e-beam adoption where feasible.

sterilization, alternate technologies, gamma, X-ra↗

Laboratory Directed Research and Development FY2010 Annual Report

A premier applied-science laboratory, Lawrence Livermore National Laboratory (LLNL) has at its core a primary national security mission - to ensure the safety, security, and reliability of the nation's nuclear weapons stockpile without nuclear testing, and to prevent and counter the spread and use of weapons of mass destruction: nuclear, chemical, and biological. The Laboratory uses the scientific and engineering expertise and facilities developed for its primary mission to pursue advanced technologies to meet other important national security needs - homeland defense, military operations, and missile defense, for example - that evolve in response to emerging threats. For broader national needs, LLNL executes programs in energy security, climate change and long-term energy needs, environmental assessment and management, bioscience and technology to improve human health, and for breakthroughs in fundamental science and technology. With this multidisciplinary expertise, the Laboratory serves as a science and technology resource to the U.S. government and as a partner with industry and academia. This annual report discusses the following topics: (1) Advanced Sensors and Instrumentation; (2) Biological Sciences; (3) Chemistry; (4) Earth and Space Sciences; (5) Energy Supply and Use; (6) Engineering and Manufacturing Processes; (7) Materials Science and Technology; Mathematics and Computing Science; (8) Nuclear Science and Engineering; and (9) Physics.

36 MATERIALS SCIENCE↗

NEET In-Pile Ultrasonic Sensor Enablement-FY-2013

Several programs funded by the Department of Energy Office of Nuclear Energy (DOE-NE), such as the Fuel Cycle Research and Development, Advanced Reactor Concepts, Light Water Reactor Sustainability, and Next Generation Nuclear Plant programs, are investigating new fuels and materials for advanced and existing reactors. A key objective of such programs is to understand the performance of these fuels and materials when irradiated. The Nuclear Energy Enabling Technology (NEET) Advanced Sensors and Instrumentation (ASI) in-pile instrumentation development activities are focused upon addressing cross-cutting needs for DOE-NE irradiation testing by providing higher fidelity, real-time data, with increased accuracy and resolution from smaller, compact sensors that are less intrusive.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

NEET Enhanced Micro Pocket Fission Detector for High Temperature Reactors - FY15 Status Report

A new project, that is a collaboration between the Idaho National Laboratory (INL), the Kansas State University (KSU), and the French Atomic Energy Agency, Commissariat à l'Énergie Atomique et aux Energies Alternatives, (CEA), has been initiated by the Nuclear Energy Enabling Technologies (NEET) Advanced Sensors and Instrumentation (ASI) program for developing and testing High Temperature Micro-Pocket Fission Detectors (HT MPFD), which are compact fission chambers capable of simultaneously measuring thermal neutron flux, fast neutron flux and temperature within a single package for temperatures up to 800 °C. The MPFD technology utilizes a small, multi-purpose, robust, in-core parallel plate fission chamber and thermocouple. As discussed within this report, the small size, variable sensitivity, and increased accuracy of the MPFD technology represent a revolutionary improvement over current methods used to support irradiations in US Material Test Reactors (MTRs). Previous research conducted through NEET ASI1-3 has shown that the MPFD technology could be made robust and was successfully tested in a reactor core. This new project will further the MPFD technology for higher temperature regimes and other reactor applications by developing a HT MPFD suitable for temperatures up to 800 °C. This report summarizes the research progress for year one of this three year project. Highlights from research accomplishments include: A joint collaboration was initiated between INL, KSU, and CEA. Note that CEA is participating at their own expense because of interest in this unique new sensor. An updated HT MPFD design was developed. New high temperature-compatible materials for HT MPFD construction were procured. Construction methods to support the new design were evaluated at INL. Laboratory evaluations of HT MPFD were initiated. Electrical contact and fissile material plating has been performed at KSU. Updated detector electronics are undergoing evaluations at KSU. A project meeting was held at KSU to discuss the roles and responsibilities between INL and KSU for development of the HT MPFDs. Provide input to various irradiation programs for installation of the MPFD technology in irradiation tests. As documented in this report, FY15 funding has allowed the project to meet year one planned accomplishments to develop a HT MPFD that offers US MTR users enhanced capabilities for real-time measurement of flux and temperature with a single detector. In addition, the accomplishments of this project have attracted funding from other Department of Energy Office of Nuclear Energy (DOE-NE) programs for additional applications. The work in those programs will build on current activities completed in this NEETASI HT MPFD project, but the MPFD will be specifically tailored to meet their program needs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

DOE Energy Frontier Research Centers Center for Direct Catalytic Conversion of Biomass to Biofuels (C3Bio)

New capabilities to predict, design and control the chemistries of carbon could answer a global imperative to transition from fossil-based to sustainable transportation fuels. While the use of inexpensive hydrocarbons has been an unparalleled achievement and enabler of economic prosperity for many nations, singular dependence upon crude oil has given rise to systemic vulnerabilities in climate, energy, economic, and national security. Lignocellulosic biomass, a renewable and carbon-neutral resource, has the potential to displace an estimated annual equivalent of three billion barrels of oil in the U.S. alone (National Research Council 2009, U. S. Department of Energy, 2011). However, biomass has only one-third the energy density of crude oil (Agrawal and Singh 2009, Richard 2010) and lacks petroleum’s versatility as a feedstock for fuels and chemicals. These limitations keep biomass conversion below the efficiency level needed for strategic impact while the scientific challenge of routing carbon from one molecular context to another remains unmet. In 2009, the Center for Direct Catalytic Conversion of Biomass to Biofuels (C3Bio) recognized the potential of chemical catalysis and fast pyrolysis to overcome such limitations by transforming the main components of biomass (cellulose, xylan, and lignin) from grasses and trees directly to liquid hydrocarbons and aromatic co-products. Enabled by the EFRC high-risk, high-reward approach to grand challenge science, C3Bio researchers have been key national players in disrupting the conventional paradigm of the cellulosic biorefinery into a new future of “no carbon left behind”—the full utilization of carbon from plant cell walls in energy-dense fuels (Fig. 1). We identified catalytic and fast-pyrolytic pathways that utilize cellulose, xylan and, most significantly, lignin. We developed catalytic processes that deoxygenate and transform monomers and isolated polymers into useful products and tested their use with intact biomass. We gained control of lignin synthesis within plants and initiated tailoring biomass to its end-use through the tools of plant molecular biology and genetic engineering. C3Bio breakthroughs have increased the energy density of biomass-derived substrates via catalytic and pyrolytic conversions into products such as benzoquinones, furfural and hydroxymethylfurfural, levoglucosan and levulinic acid, methoxypropylphenols and propylbenzene. Such advances in biomass conversion would not have been possible without simultaneous advances in analytical instrumentation and methodologies, and imaging technologies and applications. The legacy science developed by C3Bio enables design and control strategies for achieving a targeted product portfolio of fuel and chemical feedstocks from a diverse range of native and tailored biomass. Our research provides the knowledge base required for a bio-economy with product streams as diverse in functionality as those of the petrochemical industry. Coupling targeted computational modeling with experimentation, we achieved: (1) fundamental understanding of biopolymers and cell wall architecture assembly, (2) discovery of new chemistries that allow the development of highly selective pathways to fuels and desirable chemicals, and (3) an integrated systems-level understanding to control catalytic and pyrolytic pathways.

09 BIOMASS FUELS↗

Enhanced Micro-Pocket Fission Detector for High Temperature Reactors - FY17 FInal Project Report

A collaboration between the Idaho National Laboratory (INL), the Kansas State University (KSU), and the French Atomic Energy Agency, Commissariat à l'Énergie Atomique et aux Energies Alternatives, (CEA), has been initiated by the Nuclear Energy Enabling Technologies (NEET) Advanced Sensors and Instrumentation (ASI) program for developing and testing High Temperature Micro-Pocket Fission Detectors (HT MPFD), which are compact fission chambers capable of simultaneously measuring thermal neutron flux, fast neutron flux and temperature within a single package for temperatures up to 800 °C. The MPFD technology utilizes a small, multi-purpose, robust, in-core fission chambers and thermocouple. As discussed within this report, the small size, variable sensitivity, and increased accuracy of the MPFD technology represent a revolutionary improvement over current methods used to support irradiations in US Material Test Reactors (MTRs). Previous research conducted through NEET ASI1-3 has shown that the MPFD technology could be made robust and was successfully tested in a reactor core. This new project will further the MPFD technology for higher temperature regimes and other reactor applications by developing a HT MPFD suitable for temperatures up to 800 °C. This report summarizes the research progress for this three year project.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Draft Methodology for Cybersecurity Analysis for Adoption of Wireless Technology in Nuclear Power Plants

The report is delivered as DOE-NE Cybersecurity Program Milestone M2CT-22IN1104014-Industry cybersecurity guidance adoption status. The milestone is specifically to document the process and the status of the efforts towards developing guidance in support of industry’s adoption of wireless communication technologies. To transform the operation of nuclear power plants, including domestic light-water reactors, advanced reactors, microreactors, and fission battery, for grid and non-grid applications, secure and resilient wireless capabilities are required. In addition, to realize new operational concepts such as autonomous operation and remote monitoring, advanced sensor, and instrumentation, wireless technology is essential. However, industry implementation is low, and there is no technical basis for how to understand and address potential risks for wireless communications for critical plant functions. A methodology with a technical basis for implementing secure wireless communication is crucial. This wireless adoption methodology is intended to assist a licensee in identifying an appropriate technological approach for securing wireless communications in nuclear power plant. However, this methodology does not provide guidance for addressing wireless design criteria or for addressing all the cybersecurity commitments in licensees’ cybersecurity plans (CSPs) including addressing security impact analysis that a licensee must perform before an update to a Critical Digital Asset (CDA). This methodology guides a licensee through a process of evaluating a proposed wireless implementation and drafting a plant change notification for an example use case. The example is a generic/nonproprietary version of the first test case of the methodology, which, if successfully implemented, is part of the consideration for protecting other functions’ use of wireless in a cybersecure manner.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Assessment of Readout Techniques for Passive Monitors

This fiscal year (FY) 2023 report on passive temperature sensors covers two main objectives: to demonstrate that the optical dilatometer can successfully process disc shaped silicon carbide (SiC) temperature monitors (TMs), and to demonstrate proof of concept for using the capacitance readout method to read printed melt wires. The SiC objective was successfully met by annealing and analyzing, via optical dilatometry, all eight 3-mm SiC discs provided by the Nuclear Science User Facilities (NSUF) Idaho State University (ISU) Nanostructured Steels for Enhanced Radiation Tolerance (N SERT) experiment, which was irradiated at Idaho National Laboratory (INL)’s Advanced Test Reactor (ATR). Per the ISU N SERT experiment, capsule 1 (KGT 3828 1 and KGT 3828-2) had a design temperature of 300°C +/- 50°C and an exposure of 2 dpa +/- 10%; capsule 2 (KGT 4600 and KGT 4609) had a design temperature of 300°C +/- 50°C and an exposure of 6 dpa +/- 10%; capsule 3 (KGT 4639 C and KGT 4639-D) had a design temperature of 500°C +/- 50°C and an exposure of 6 dpa +/- 10%; and capsule 4 (KGT 3841 3 and KGT 3841 4) had a design temperature of 500°C +/- 50°C and an exposure of 2 dpa +/- 10%. The target exposure rates, in dpa, are the neutron damage for various types of nanostructured steels. All but three SiC TMs (KGT 4600, KGT 4639 D, and KGT 3841 4) revealed averaged peak irradiation temperatures that fell within the design temperature ranges. The three SiC TMs that did not fall within the design temperatures ranges were at least 100°C below that target temperature. Furthermore, SiC TM KGT 3841 C revealed two irradiation regimes: one closer to the 300°C design temperature, and the other closer to the 500°C design temperature. Also, all the SiC TMs’ averaged peak irradiation temperatures came in anywhere between 20°C and 240°C below the irradiation temperatures predicted by the thermal models. This showed the optical dilatometry method to be a reliable and less time intensive process for determining averaged peak irradiation temperatures from passive SiC TMs such as rods and discs. Under the Advanced Sensors and Instrumentation (ASI) program in FY-23, Boise State University (BSU) proposed to demonstrate proof of concept for using a capacitance readout technique applicable to printed melt wires; however, they were stymied by the complexity of the capacitance readout method. In support of the BSU work, INL developed an additively manufactured (AM) ceramic package for encapsulating the new melt wires. Inks were synthesized at BSU that used new protocols rather than following previously established protocols implemented at INL, and testing of various temperatures was conducted at BSU to evaluate the melting behaviors of the printed melt wires. The result was that the capacitance readout technique showed promise but also created more challenges than originally anticipated. For example, the tin ink synthesized at BSU showed unusual melting behaviors that did nothing to enhance the performance of the final printed melt wire prototype in terms of the capacitance readout method. To make the proof of concept work when applied to the printed melt wires, the ASI program would need to invest further resources and time. Consequently, the program is not planning to continue this proof of concept work in FY-24, based on the progress and findings achieved in FY-23.

36 MATERIALS SCIENCE↗

OPEN-Augmented Reality GUI for Bioenergy Crop Phenotyping and Precision Agriculture (Donald Danforth Plant Science Center Final Scientific Technical Report)

The project led by the Donald Danforth Plant Science Center, in collaboration with Arizona State University, George Washington University, and Saint Louis University, has made significant strides in advancing the phenotypic analysis of bioenergy crops through the development of an innovative AI processing pipeline. This initiative was primarily funded by ARPA-E, with additional cost-sharing provided by the participating institutions. The project successfully utilized a variety of sensors—3D scanners, thermal, RGB, and hyperspectral—to refine algorithms for data-driven trait signature identification and improve the classification and visualization of plant traits. The developed AI processing pipeline is capable of handling the complex, multidimensional data characteristic of dynamic agricultural environments. 1) Contributions to understanding: The research has advanced the field of plant phenomics by showcasing the synergistic use of various sensor data to enhance the precision of trait analysis in bioenergy crops. Through the integration of 3D scanners, thermal, RGB, and hyperspectral sensors, the project has developed robust data-driven trait signature algorithms and visualization techniques. These innovations have facilitated detailed monitoring and management of plant traits, providing vital insights into plant growth dynamics and stress responses. Further, the project has broadened our understanding of how machine learning can be effectively applied in multi-sensor environments to refine trait analysis. By leveraging diverse datasets, the research has not only improved the accuracy of phenotypic assessments but also established a versatile methodological framework that can be extended beyond agriculture to other fields requiring detailed phenotypic analysis. 2) Technical effectiveness and economic feasibility: The AI processing pipeline developed in this project demonstrated significant technical effectiveness, achieving high throughput analysis of extensive phenotypic data and meeting targeted accuracies. This system exemplified the capability of advanced machine learning technologies to efficiently manage and analyze large, complex datasets. Economically, the implementation of the project-developed pipelines may offer substantial cost savings across multiple sectors. It enhances data analysis processes and significantly reduces the need for manual data interpretation, thereby decreasing both the time and resources required. 3) Public benefit: The project has significantly broadened the scope of agricultural methodologies to enhance phenotypic analysis, with potential applications in various sectors beyond agriculture. Additionally, the initiative fostered an enriching educational and collaborative environment, significantly enhancing the technical skills of participants. It also made substantial contributions to the scientific community by providing open-access data sets and tools, encouraging ongoing research and development across various disciplines. Overall, the project not only met its scientific goals but also showcased the extensive utility of integrating advanced machine learning and sensor data analysis technologies. These advancements have proven instrumental in driving forward both theoretical research and practical applications, setting a strong foundation for future explorations and innovations in data-driven science.

60 APPLIED LIFE SCIENCES↗

The Jefferson Lab Eta Factory Experiment and Applications of PbWO4 Calorimeters in Future Experimental Facilities

The goal of the new JLab Eta Factory (JEF) experiment, conducted with the GlueX detector in Hall D at Jefferson Lab, is to perform measurements of various ¿(') decays with a primary focus on rare neutral modes. The experiment’s physics program ranges from precision tests of low-energy QCD to searches for gauge bosons with masses below 1 GeV that could couple the Standard Model (SM) sector to the dark sector. The experiment will collect a high-statistics data sample of ¿(') mesons produced via a beam of tagged photons. The GlueX detector features a large, nearly uniform acceptance for both neutral and charged particles, enabling efficient identification of complex multi-particle final states. To meet the requirements of the JEF experiment, the inner section of the forward lead-glass calorimeter in the GlueX detector has been upgraded with lead tungstate (PbWO4) scintillating crystals. PbWO4 offers exceptional characteristics, such as a small radiation length and Molire radius, and large light yield, that make it ideal for constructing high- granularity, high-resolution, radiation-hard detectors. These properties enable excellent spatial separation and energy resolution of reconstructed electromagnetic showers, establishing PbWO4 as the material of choice for many high-precision experiments. The JEF experiment began data collection in April 2025 and will operate concurrently with the GlueX experiment, whose primary objective is the search for gluonic excitations in the meson spectrum. I will give an overview of the JEF experiment, the GlueX detector, and the feasibility of further upgrades to support future ¿ physics studies. Special attention will be given to the newly constructed PbWO4 scintillating calorimeter and recent advancements in calorimeter instrumentation.

Somov, Alexander↗

M3AS-25IN1002073: Analysis of data from irradiation testing of printed strain gauges in prototypic nuclear environments

Advancement in additively manufactured strain gauges help address critical technology gaps to accurately monitor real-time materials behavior in reactor experiments. This is critical as it provides data to inform predictive models and simulations that enhance the development of reactors and fuel cycle systems. In this report, additively manufactured strain gauges are exposed to a neutron irradiation environment at the Ohio State University Research Reactor. This report goes over a 2-week campaign for neutron irradiating printed resistive strain gauges and capacitive strain gauges. These results complement the prior separate effects (i.e., mechanical strain, temperature, etc.) testing that were performed on these additive manufactured sensors and presented in prior milestone reports. These results also help progress our understanding of their usage in harsh environment applications. The outcome of developing advanced sensing and instrumentation capabilities plays an important role in increasing the safety, reliability, and energy efficiency of both next-generation and existing nuclear reactors.

36 - MATERIALS SCIENCE↗

Carrier-assisted One-pot Sample Preparation for Targeted Proteomics Analysis of Small Numbers of Human Cells

Protein analysis of small numbers of human cells is primarily achieved by targeted proteomics with antibody-based immunoassays, which have inherent limitations (e.g., low multiplex and unavailability of antibodies for new proteins). Mass spectrometry (MS)-based targeted proteomics has emerged as an alternative because it is antibody-free, high multiplex, and has high specificity and quantitation accuracy. Recent advances in MS instrumentation make MS-based targeted proteomics possible for multiplexed quantification of highly abundant proteins in single cells. However, there is a technical challenge for effective processing of single cells with minimal sample loss for MS analysis. To address this issue, we have recently developed a convenient protein carrier-assisted one-pot sample preparation coupled with liquid chromatography (LC) - selected reaction monitoring (SRM) termed cLC-SRM for targeted proteomics analysis of small numbers of human cells. This method capitalizes on using the combined excessive exogenous protein as a carrier and low-volume one-pot processing to greatly reduce surface adsorption losses as well as high-specificity LC-SRM to effectively address the increased dynamic concentration range due to the addition of exogeneous carrier protein. Its utility has been demonstrated by accurate quantification of most moderately abundant proteins in small numbers of cells (e.g., 10-100 cells) and highly abundant proteins in single cells. The easy-to-implement features and no need for specific devices make this method readily accessible to most proteomics laboratories. In this study, we have provided a detailed protocol for cLC-SRM analysis of small numbers of human cells including cell sorting, cell lysis and digestion, LC-SRM analysis, and data analysis. Further improvements in detection sensitivity and sample throughput are needed towards targeted single-cell proteomics analysis. We anticipate that cLC-SRM will be broadly applied to biomedical research and systems biology with the potential of facilitating precision medicine.

60 APPLIED LIFE SCIENCES↗

Time evolution of elemental ratios in solar energetic particle events

Heavy ion ratio abundances in solar energetic particle (SEP) events, e.g., Fe/O, often exhibit decreases over time. Using particle instruments on the Advanced Composition Explorer, Solar and Heliospheric Observatory and Solar Terrestrial Relations Observatory spacecraft, we analyzed heavy ion data from 4 SEP events taking place between 2006 December and 2014 December. We constructed 36 different ionic pairs and studied their time evolution in each event. We quantified the temporal behavior of abundant SEP ratios by fitting the data to derive a decay time constant B. We also considered the ratio of ionic mass-to-charge for each pair, the S value given, e.g., for Fe/O by S{sub Fe/O}=(M/Q){sub Fe}/(M/Q){sub O}. We found that the temporal behavior of SEP ratios is ordered by the value of S: ratios with S>1 showed decreases over time (i.e., B<0) and those with S<1 showed increases (B>0). We plotted B as a function of S and observed a clear monotonic dependence: ratios with a large S decayed at a higher rate. A prominent discontinuity at S = 2.0 (corresponding to He/H) was found in three of the four events, suggesting anomalous behavior of protons. The X/H ratios often show an initial increase followed by a decrease, and decay at a slower rate. We discuss possible causes of the observed B versus S trends within current understanding of SEP propagation.

79 ASTRONOMY AND ASTROPHYSICS↗

Shallow cumuli cover and its uncertainties from ground-based lidar–radar data and sky images

Cloud cover estimates of single-layer shallow cumuli obtained from narrow field-of-view (FOV) lidar–radar and wide-FOV total sky imager (TSI) data are compared over an extended period (2000–2017 summers) at the established United States Atmospheric Radiation Measurement mid-continental Southern Great Plains site. We quantify the impacts of two factors on hourly and sub-hourly cloud cover estimates: (1) instrument-dependent cloud detection and data merging criteria and (2) FOV configuration. Enhanced observations at this site combine the advantages of the ceilometer, micropulse lidar (MPL) and cloud radar in merged data products. Data collected by these three instruments are used to calculate narrow-FOV cloud fraction (CF) as a temporal fraction of cloudy returns within a given period. Sky images provided by TSI are used to calculate the wide-FOV fractional sky cover (FSC) as a fraction of cloudy pixels within a given image. To assess the impact of the first factor on CF obtained from the merged data products, we consider two additional subperiods (2000–2010 and 2011–2017 summers) that mark significant instrumentation and algorithmic advances in the cloud detection and data merging. We demonstrate that CF obtained from ceilometer data alone and FSC obtained from sky images provide the most similar and consistent cloud cover estimates; hourly bias and root-mean-square difference (RMSD) are within 0.04 and 0.12, respectively. However, CF from merged MPL–ceilometer data provides the largest estimates of the multiyear mean cloud cover, about 0.12 (35 %) and 0.08 (24 %) greater than FSC for the first and second subperiods, respectively. CF from merged ceilometer–MPL–radar data has the strongest subperiod dependence with a bias of 0.08 (24 %) compared to FSC for the first subperiod and shows no bias for the second subperiod. The strong period dependence of CF obtained from the combined ceilometer–MPL–radar data is likely results from a change in what sensors are relied on to detect clouds below 3 km. After 2011, the MPL stopped being used for cloud top height detection below 3 km, leaving the radar as the only sensor used in cloud top height retrievals. To quantify the FOV impact, a narrow-FOV FSC is derived from the TSI images. We demonstrate that FOV configuration does not modify the bias but impacts the RMSD (0.1 hourly, 0.15 sub-hourly). In particular, the FOV impact is significant for sub-hourly observations, where 41 % of narrow- and wide-FOV FSC differ by more than 0.1. A new “quick-look” tool is introduced to visualize impacts of these two factors through integration of CF and FSC data with novel TSI-based images of the spatial variability in cloud cover. The influence of cloud field organization, such cloud streets parallel to the wind direction, on narrow- and wide-FOV cloud cover estimates can be visually assessed.

54 ENVIRONMENTAL SCIENCES↗