Search NASA⌕ Search

SEARCH · Search NASA

Results for “BEAM LINES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Saturation curve of SiO{sub 2} component in rutile-type GeO{sub 2}: A recoverable high-temperature pressure standard from 3 GPa to 10 GPa

The accuracy and precision of pressure measurements and the pursuit of reliable and readily available pressure scales at simultaneous high temperatures and pressures are still topics in development in high pressure research despite many years of work. In situ pressure scales based on x-ray diffraction are widely used but require x-ray access, which is lacking outside of x-ray beam lines. Other methods such as fixed points require several experiments to bracket a pressure calibration point. In this study, a recoverable high-temperature pressure gauge for pressures ranging from 3 GPa to 10 GPa is presented. The gauge is based on the pressure-dependent solubility of an SiO{sub 2} component in the rutile-structured phase of GeO{sub 2} (argutite), and is valid when the argutite solid solution coexists with coesite. The solid solution varies strongly in composition, mainly in pressure but also somewhat in temperature, and the compositional variations are easily detected by x-ray diffraction of the recovered products because of significant changes in the lattice parameters. The solid solution is measured here on two isotherms, one at 1200 °C and the other at 1500 °C, and is developed as a pressure gauge by calibrating it against three fixed points for each temperature and against the lattice parameter of MgO measured in situ at a total of three additional points. A somewhat detailed thermodynamic analysis is then presented that allows the pressure gauge to be used at other temperatures. This provides a way to accurately and reproducibly evaluate the pressure in high pressure experiments and applications in this pressure-temperature range, and could potentially be used as a benchmark to compare various other pressure scales under high temperature conditions. - Graphical abstract: The saturation curve of SiO{sub 2} in TiO{sub 2} shows a strong pressure dependence and a strong dependence of unit cell volume on composition. This provides an opportunity to use this saturation curve as a measurement of pressure during a high-pressure experiment. The curve is a sensitive measure of pressure from 3 GPa to 10 GPa at high temperatures. The pressure is derived from lattice parameter measurements on the recovered solid solution, meaning that in-situ measurements are not necessary to evaluate the pressure of the experiment. - Highlights: • The unit cell of a saturated GeO{sub 2}–SiO{sub 2} solid solution is used as a pressure sensor. • We measure nine bracketed pressure points on the GeO{sub 2}–SiO{sub 2} saturation surface. • We provide a pressure calibrant from 3 GPa to 10 GPa at two temperatures. • Four points are measured at 1200 °C and five points at 1500 °C. • A thermodynamic model is developed for use of the calibrant at other temperatures.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Determination of the composition of Co-Pt thin films with quantitative electron-probe microanalysis

Quantitative electron-probe microanalysis (EPMA) with energy-dispersive (EDS) and wavelength-dispersive (WDS) X-ray spectroscopy was performed to determine the chemical composition of Co-Pt ferromagnetic thin films. The conventional 'bulk' EPMA approach was applied and tested in detail by using several analytical set-ups with different combinations of Co and Pt spectral lines, beam energies and quantitative matrix-correction programs. The analyses with dedicated, thin-film EPMA programs were also made for comparison. The results were critically examined in order to assess their reliability and accuracy. The commonly used EDS analyses showed significant scatter between the set-ups and generally suffered from a poor analytical sensitivity. In contrast, the quantitative WDS analyses were fully consistent and practically independent of the analytical set-up. With the optimized WDS a high analytical precision, an improved sensitivity and an ultimate quantitative accuracy of better than 1% relative were achieved. The results confirmed that by using WDS microanalysis at low beam energies and by measuring the low-energy Co-L{alpha} and Pt-M{alpha} X-rays we were able to obtain the most accurate and reliable, quantitative, compositional analyses of Co-Pt thin films with thicknesses down to {approx} 100 nm.

36 MATERIALS SCIENCE↗

Coded source neutron imaging at the PULSTAR reactor

A neutron imaging facility is located on beam-tube No.5 of the 1-MW PULSTAR reactor at North Carolina State University. An investigation of high resolution imaging using the coded source imaging technique has been initiated at the facility. Coded imaging uses a mosaic of pinholes to encode an aperture, thus generating an encoded image of the object at the detector. To reconstruct the image data received by the detector, the corresponding decoding patterns are used. The optimized design of coded mask is critical for the performance of this technique and will depend on the characteristics of the imaging beam. In this work, a 34 x 38 uniformly redundant array (URA) coded aperture system is studied for application at the PULSTAR reactor neutron imaging facility. The URA pattern was fabricated on a 500 ?m gadolinium sheet. Simulations and experiments with a pinhole object have been conducted using the Gd URA and the optimized beam line.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The MINER$\nu$A Data Acquisition System and Infrastructure

MINERvA (Main INjector ExpeRiment v-A) is a new few-GeV neutrino cross-section experiment that began taking data in the FNAL NuMI (Fermi National Accelerator Laboratory Neutrinos at the Main Injector) beam-line in March of 2010. MINERvA employs a fine-grained scintillator detector capable of complete kinematic characterization of neutrino interactions. This paper describes the MINERvA data acquisition system (DAQ) including the readout electronics, software, and computing architecture.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A new timing detector for the CT-PPS project

The CT-PPS detector will be installed close to the beam line on both sides of CMS, 200 m downstream the interaction point. This detector will measure forward scattered protons, allowing detailed studies of diffractive hadron physics and Central Exclusive Production. The main components of the CT-PPS detector are a silicon tracking system and a timing system. In this contribution we present the proposal of an innovative solution for the timing system, based on Ultra-Fast Silicon Detectors (UFSD). UFSD are a novel concept of silicon detectors potentially able to obtain the necessary time resolution (~20 ps on the proton arrival time). The use of UFSD has also other attractive features as its material budget is small and the pixel geometries can be tailored to the precise physics distribution of protons. UFSD prototypes for CT-PPS have been designed by CNM (Barcelona) and FBK (Trento): we will present the status of the sensor productions and of the low-noise front-end electronics currently under development and test.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A magnetic field cloak for charged particle beams

Shielding charged particle beams from transverse magnetic fields is a common challenge for particle accelerators and experiments. In this study, we demonstrate that a magnetic field cloak is a viable solution. It allows for the use of dipole magnets in the forward regions of experiments at an Electron Ion Collider (EIC) and other facilities without interfering with the incoming beams. The dipoles can improve the momentum measurements of charged final state particles at angles close to the beam line and therefore increase the physics reach of these experiments. In contrast to other magnetic shielding options (such as active coils), a cloak requires no external powering. We discuss the design parameters, fabrication, and limitations of a magnetic field cloak and demonstrate that cylinders made from 45 layers of YBCO high-temperature superconductor, combined with a ferromagnetic shell made from epoxy and stainless steel powder, shield more than 99% of a transverse magnetic field of up to 0.45 T (95% shielding at 0.5 T) at liquid nitrogen temperature. Lastly, the ferromagnetic shell reduces field distortions caused by the superconductor alone by 90% at 0.45 T.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The GlueX Start Counter Detector

The design, simulation, fabrication, calibration, and performance of the GlueX Start Counter detector is described. The Start Counter was designed to operate at integrated rates of up to 9 MHz with a timing resolution in the range of 500 to 825 ps (FWHM). The Start Counter provides excellent solid angle coverage, a high degree of segmentation for background rejection, and can be utilized in the level 1 trigger for the experiment. It consists of a cylindrical array of 30 thin scintillators with pointed ends that bend towards the beam line at the downstream end. Magnetic field insensitive silicon photomultiplier detectors were used as the light sensors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Analysis of the EMCCD point-source response using x-rays

Electron Multiplying Charge Coupled Devices, EMCCD are used as x-ray detectors. The NSLS-II Soft Inelastic x-ray Scattering (SIX) beam line has two EMCCDs for x-ray detection in the spectrometer arm. The spectrometer with high resolving power disperses x-rays vertically. The x-ray vertical position on the sensor plane is related to its energy. This allows for very accurate x-ray energy measurements through x-ray coordinates. X-rays interact with silicon and create a number of electron-hole pairs proportional to the x-ray energy. Electrons drift and diffuse toward pixel gates and are collected there. The diffused electrons form a charge cloud distributed over several neighboring pixels. This charge sharing enables coordinate measurements with accuracy better than the pixel pitch. The charge distribution shape has to be taken into account to achieve ultimate accuracy in coordinate measurements. In this paper, we present a method of the charge distribution shape analysis and demonstrate its applications. The drift and diffusion of electrons ftom the point of generation to pixel gates results in the bell-shaped electron cloud usually approximated by Gaussian shape. The number of electrons collected under a pixel is proportional to the shape function integral. These electron packets get transferred to the sense node of the output amplifier. The transfer process could introduce distortions to the original charge distribution. For example, during transfers, electrons in the packet could be exposed to traps if they are present in the sensor. The trapping and later the release processes distort the apparent shape of the charge distribution. Therefore, deviations of the charge distribution shape ftom the originally symmetrical form can indicate the presence of trap centers in the sensor and can be used for sensor diagnostics.

47 OTHER INSTRUMENTATION↗

Precision Møller polarimetry for PREX-2 and CREX

The PREX-2 and CREX experiments in Hall A at Jefferson Lab are precision measurements of parity violating elastic electron scattering from complex nuclei. One requirement was that the incident electron beam polarization, typically , be known with 1% precision. We commissioned and operated a Møller polarimeter on the beam line that exceeds this requirement, achieving a precision of 0.89% for PREX-2, and 0.85% for CREX. The uncertainty is purely systematic, accumulated from several different sources, but dominated by our knowledge of the target polarization. Our analysis also demonstrates the need for accurate atomic wave functions in order to correct for the Levchuk Effect. We describe the details of the polarimeter operation and analysis, as well as (for CREX) a comparison to results from a different polarimeter based on Compton scattering.

43 PARTICLE ACCELERATORS↗

The MUSE beamline calorimeter

The MUon Scattering Experiment (MUSE) was motivated by the proton radius puzzle arising from the discrepancy between muonic hydrogen spectroscopy and electron–proton measurements. The MUSE physics goals also include testing lepton universality, precisely measuring two-photon exchange contribution, and testing radiative corrections. MUSE addresses these physics goals through simultaneous measurement of high precision cross sections for electron–proton and muon–proton scattering using a mixed-species beam. The experiment will run at both positive and negative beam polarities. Measuring precise cross sections requires understanding both the incident beam energy and the radiative corrections. For this purpose, a lead-glass calorimeter was installed at the end of the beam line in the MUSE detector system. Here, in this article, we discuss the detector specifications, calibration and performance. We demonstrate that the detector performance is well reproduced by simulation, and meets experimental requirements.

Calorimeter↗

A MAPS Based Micro-Vertex Detector for the STAR Experiment

For the 2014 heavy ion run of RHIC a new micro-vertex detector called the Heavy Flavor Tracker (HFT) was installed in the STAR experiment. The HFT consists of three detector subsystems with various silicon technologies arranged in 4 approximately concentric cylinders close to the STAR interaction point designed to improve the STAR detector’s vertex resolution and extend its measurement capabilities in the heavy flavor domain. The two innermost HFT layers are placed at radii of 2.8 cm and 8 cm from the beam line. These layers are constructed with 400 high resolution sensors based on CMOS Monolithic Active Pixel Sensor (MAPS) technology arranged in 10-sensor ladders mounted on 10 thin carbon fiber sectors to cover a total silicon area of 0.16 m 2 . Each sensor of this PiXeL (“PXL”) sub-detector combines a pixel array of 928 rows and 960 columns with a 20.7 μm pixel pitch together with front-end electronics and zero-suppression circuitry in one silicon die providing a sensitive area of ~3.8 cm 2 . This sensor architecture features 185.6 μs readout time and 170 mW/cm 2 power dissipation. This low power dissipation allows the PXL detector to be air-cooled, and with the sensors thinned down to 50 μm results in a global material budget of only 0.4% radiation length per layer. A novel mechanical approach to detector insertion allows us to effectively install and integrate the PXL sub-detector within a 12 hour period during an on-going multi-month data taking period. The detector requirements, architecture and design, as well as the performance after installation, are presented in this paper.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A fixed-target programme at the LHC: Physics case and projected performances for heavy-ion, hadron, spin and astroparticle studies

Here we review the context, the motivations and the expected performances of a comprehensive and ambitious fixed-target programme using the multi-TeV proton and ion LHC beams. We also provide a detailed account of the different possible technical implementations ranging from an internal wire target to a full dedicated beam line extracted with a bent crystal. The possibilities offered by the use of the ALICE and LHCb detectors in the fixed-target mode are also reviewed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Low-cost plasma immersion ion implantation doping for Interdigitated back passivated contact (IBPC) solar cells

Here, we present progress to develop low-cost interdigitated back contact solar cells with pc-Si/SiO 2 /c-Si passivated contacts formed by plasma immersion ion implantation (PIII). PIII is a lower-cost implantation technique than traditional beam line implantation due to its simpler design, lower operating costs, and ability to run high doses (1E14-1E18 cm -2 ) at low ion energies (20 eV-10 keV). These benefits make PIII ideal for high throughput production of patterned passivated contacts, where high-dose, low-energy implantations are made into thin (20-200 nm) a-Si layers instead of into the wafer itself. For this work symmetric passivated contact test structures (~100 nm thick) grown on n-Cz wafers with pH3 PIII doping gave implied open circuit voltage (iV oc ) values of 730 mV with J o values of 2 fA/cm 2 . Samples doped with B 2 H 6 gave iV oc values of 690 mV and J o values of 24 fA/cm 2 , outperforming BF 3 doping, which gave iV oc values in the 660-680 mV range. Samples were further characterized by SIMS, photoluminescence, TEM, EELS, and post-metallization TLM to reveal micro- and macro-scopic structural, chemical and electrical information.

14 SOLAR ENERGY↗

Neutron and X-ray powder diffraction study of skutterudite thermoelectrics

N- and p-type filled-skutterudite materials prepared for thermoelectric power generation modules were analyzed by neutron diffraction at the POWGEN beam line of the Spallation Neutron Source (SNS) and X-ray diffraction (XRD). The skutterudite powders were processed by melt spinning, followed by ball milling and annealing. The n-type material consists of Ba–Yb–Co–Sb and the p-type material consists of Di–Fe–Ni–Sb or Di–Fe–Co–Sb (Di = didymium, an alloy of Pr and Nd). Powders for prototype module fabrication from General Motors and Marlow Industries were analyzed in this study. XRD and neutron diffraction studies confirm that both the n- and p-type materials have cubic symmetry. Structural Rietveld refinements determined the lattice parameters and atomic parameters of the framework and filler atoms. The cage filling fraction was found to depend linearly on the lattice parameter, which in turn depends on the average framework atom size. Ultimately, this knowledge may allow the filling fraction of these skutterudite materials to be purposefully adjusted, thereby tuning the thermoelectric properties.

36 MATERIALS SCIENCE↗

Advancing X-ray quantum imaging through Monte-Carlo simulations

Imaging with X-rays poses fundamental limits due to radiation damage of the highly energetic photons. This becomes problematic for sensitive biological systems such as subcellular structures. Lowering the radiation dose, without sacrificing the signal-to-noise ratio, would be desirable for any kind of imaging modalities involving X-rays. To achieve this goal, quantum imaging with entangled X-ray photons constitutes a promising route. Production of biphotons have been demonstrated in the X-ray regime by the process of Spontaneous Parametric Down-Conversion (SPDC). However, compared to SPDC in the regime of visible light, the production rate for X-ray biphotons is extremely low. With the introduction of new high average brightness X-ray sources, such as 4th generation synchrotrons and high repetition rate Free-Electron X-ray Lasers (XFEL), quantum imaging may become practical. We introduce a ray tracing approach using Monte-Carlo sampling, specifically designed for quantum imaging with entangled X-ray photons generated by SPDC. By simulation, the superior image quality of quantum over classical imaging methods is demonstrated using realistic experimental conditions available at high repetition rate XFELs. With these simulations, we can efficiently assist the design of future experiments at beam lines, which can substantially accelerate the advancement of X-ray quantum imaging and reduce costs.

Entangled Photons↗

Picosecond x-ray absorption measurements of the ligand substitution dynamics of Fe(CO){sub 5} in ethanol.

Ultrafast X-ray absorption near edge spectroscopy has been carried out for photo excited iron pentacarbonyl in ethanol with 2 picosecond resolution. A temporal resolution limited dissociation process was observed, followed by the formation of the mono-substituted complex Fe(CO){sub 4}EtOH within a few tens of picoseconds. The measurements have been carried out with a newly developed X-ray absorption instrument at station 7 ID-C of the Advanced Photon Source. The results show that single picosecond temporal resolution can be achieved at a synchrotron beam line.

43 PARTICLE ACCELERATORS↗

Radiative decay of the free neutron

The theory of quantum electrodynamics predicts that beta decay of the neutron into a proton, electron, and antineutrino should be accompanied by a continuous spectrum of soft photons. We recently reported the first observation of this radiative decay mode of the neutron, measured by recording photons in coincidence with both the electron and proton emitted in neutron decay. The experiment was performed on the NG-6 Fundamental Physics Beam Line at the National Institute of Standards and Technology (NIST) Center for Neutron Research (NCNR). A new experiment is under development to measure both the branching ratio and energy spectrum for radiative decay with a relative standard uncertainty of a few percent. We briefly review the fundamental neutron physics program at the NCNR and describe the new radiative decay experiment.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗