Theoretical and testing performance of an innovative indirect evaporative chiller

An indirect evaporative chiller is a device used to produce chilled water at a temperature between the wet bulb temperature and dew point of the outdoor air, which can be used in building HVAC systems. This article presents a theoretical analysis and practical performance of an innovative indirect evaporative chiller. First, the process of the indirect evaporative chiller is introduced; then, the matching characteristics of the process are presented and analyzed. It can be shown that the process that produces cold water by using dry air is a nearly-reversible process, so the ideal produced chilled water temperature of the indirect evaporative chiller can be set close to the dew point temperature of the chiller's inlet air. After the indirect evaporative chiller was designed, simulations were done to analyze the output water temperature, the cooling efficiency relative to the inlet dew point temperature, and the COP that the chiller can performance. The first installation of the indirect evaporative chiller of this kind has been run for 5 years in a building in the city of Shihezi. The tested output water temperature of the chiller is around 14-20 C, which is just in between of the outdoor wet bulb temperature and dew point. The tested COP{sub r,s} of the developed indirect evaporative chiller reaches 9.1. Compared with ordinary air conditioning systems, the indirect evaporative chiller can save more than 40% in energy consumption due to the fact that the only energy consumed is from pumps and fans. An added bonus is that the indirect evaporative chiller uses no CFCs that pollute to the aerosphere. The tested internal parameters, such as the water-air flow rate ratio and heat transfer area for each heat transfer process inside the chiller, were analyzed and compared with designed values. The tested indoor air conditions, with a room temperature of 23-27 C and relative humidity of 50-70%, proved that the developed practical indirect evaporative chiller successfully satisfy the indoor air conditioning load for the demo building. The indirect evaporative chiller has a potentially wide application in dry regions, especially for large scale commercial buildings. Finally, this paper presented the geographic regions suitable for the technology worldwide. (author)

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

COMET: A Domain-Specific Compilation of High-Performance Computational Chemistry

The computational power increases over the past decades have greatly enhanced the ability to simulate chemical reactions and understand ever more complex transformations. Tensor contractions are the fundamental computational building block of these simulations. These simulations have often been tied to one platform and restricted in generality by the interface provided to the user. The expanding prevalence of accelerators and researcher demands necessitate a more general approach which is not tied to specific hardware or requires contortion of algorithms to specific hardware platforms. In this paper we present COMET, a domain-specific programming language and compiler infrastructure for tensor contractions targeting heterogeneous accelerators. We present a system of progressive lowering through multiple layers of abstraction and optimization that achieves up to 1.98×speedup for 30 tensor contractions commonly used in computational chemistry and beyond.

Mutlu, Erdal↗

Impact of installation faults in air conditioners and heat pumps in single-family homes on U.S. energy usage

To ensure that new residential air conditioners and heat pumps operate optimally, care must be taken during the initial system design and installation to avoid missteps that immediately degrade a system’s performance. Laboratory and simulation studies have quantified the impact that faults can have on capacity and efficiency. Field studies have demonstrated that installation-related faults are commonplace. However, the national impact of installation-related faults cannot be accurately estimated by only simulating a limited number of homes at several fault levels because of the variety of home characteristics and climates involved. In our analysis, we use an improved residential building stock simulation tool to predict the annual energy increase and additional utility costs resulting from two common installation faults: indoor airflow rate and refrigerant charge level. Our method considers the wide range of building characteristics and climate zones of the U.S. housing stock. We use existing field data to develop fault intensity probability distributions to inform our analysis. The study shows that these two faults result in approximately 20.7 TWh/y of additional energy use for central air conditioners and air-source heat pumps in U.S. single-family detached homes, which is a 9% increase over baseline (no-fault) usage, costing homeowners approximately $2.5 billion annually on utility bills. Air-source heat pumps are responsible for a disproportionate fraction of this energy use increase because of the larger number of operating hours compared to central air conditioners and the sensitivity of heating mode performance to the faults analyzed compared to cooling mode.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Impact of Insulation Strategies of Cross-Laminated Timber Assemblies on Energy Use, Peak Demand, and Carbon Emissions

Cross-Laminated Timber (CLT) panels have many structural benefits but do not have much thermal resistance. We have developed a solution to insulate CLT structures that uses high-performance insulation panels that provide R-values up to R40/inch. The CLT panels are made of layers of wood laminates (three, five, seven or more). The solution replaces some of the wood laminates in the CLT production with the insulation panels in a staggered fashion so that the wood laminates maintain contact throughout the panel, ensuring the CLT panel’s structural integrity. The insulated CLT panels have factory-installed water-resistive barriers reducing the installation time by eliminating installing insulation and water-resistive barriers on site. Per simulations, the CLT/insulation panel achieved code-required insulation levels with commonly available insulation materials. The significance of the thermal mass of CLT/insulation hybrid building envelopes was quantified by comparing the whole building energy performance and peak demand of traditional low mass and CLT wall assemblies resulting in up to 7% reduction in peak demand for cooling in Knoxville, TN, in a multifamily building. Buildings contribute over 40 percent of carbon emissions. The proposed CLT/insulation hybrid building envelope addresses both operational and embodied carbon by having high thermal resistances due to the embedded insulation sections and eliminating the use of high embodied carbon materials such as steel and concrete. The carbon benefit is estimated.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Potential of Data Center Controls in Grid Services

The rapid proliferation of large data centers brings both challenges and opportunities for grid reliability. The data center resources and their potential flexibility have the potential to contribute resources to grid operations. Through capabilities like energy shifting and resource coordination, data centers can help reduce their net demand on the transmission network, as well as provide additional grid services to support reliable operation on the grid. While transient and long-term grid planning and operations are the scenarios that draw most attention, the quasi-steady state timeseries (QSTS) operation of data centers and grid bring interesting scenarios that can help evaluate the data center controls to aid grid services. This work is focused on modeling data centers for QSTS applications – incorporating the AI data center load profiles and building on the PNNL digital twin model for the thermal management loads to enable simulation studies to reveal the impact of data center controls on grid performance. This includes the integration of a QSTS battery and natural gas generator model to incorporate local resource impacts to the system. The simulation study is performed with a modified IEEE 24-Bus transmission system. Scenarios are focused on evaluating the data center load impacts on the transmission system and leveraging both data center and local generation controls to mitigate those impacts and provide additional grid services. The data center controls revealed the ability to contribute to two main kinds of grid services: preventing congestion on a weak grid by coordinating the data center resources with the collocated BESS and onsite generation; and the ability to help the grid operations during stressed times of operation like during a contingency. Leveraging these and other capabilities has the potential to help data centers become grid responsive assets, aiding in both their integration into the power system and grid reliability.

power grid simulation↗

Quality Control Methods for Advanced Metering Infrastructure Data

While urban-scale building energy modeling is becoming increasingly common, it currently lacks standards, guidelines, or empirical validation against measured data. Empirical validation necessary to enable best practices is becoming increasingly tractable. The growing prevalence of advanced metering infrastructure has led to significant data regarding the energy consumption within individual buildings, but is something utilities and countries are still struggling to analyze and use wisely. In partnership with the Electric Power Board of Chattanooga, Tennessee, a crude OpenStudio/EnergyPlus model of over 178,000 buildings has been created and used to compare simulated energy against actual, 15-min, whole-building electrical consumption of each building. In this study, classifying building type is treated as a use case for quantifying performance associated with smart meter data. This article attempts to provide guidance for working with advanced metering infrastructure for buildings related to: quality control, pathological data classifications, statistical metrics on performance, a methodology for classifying building types, and assess accuracy. Advanced metering infrastructure was used to collect whole-building electricity consumption for 178,333 buildings, define equations for common data issues (missing values, zeros, and spiking), propose a new method for assigning building type, and empirically validate gaps between real buildings and existing prototypes using industry-standard accuracy metrics.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Predicting the performance of radiant technologies in attics: Reducing the discrepancies between attic specific and whole-building energy models

The use of radiant technology in attics aims to reduce the radiation component of heat transfer between the attic floor and roof decks, gables, and eaves. Recently, it has been shown that EnergyPlus underestimates the savings using radiant technologies in attic spaces. The aim of this study is to understand why EnergyPlus underestimates the performance of radiant technologies and provide a solution strategy that works within the current capabilities of EnergyPlus. The analysis uses three attic energy models as a baseline for comparison for EnergyPlus. Potential reasons for the discrepancies between the attic specific energy models and EnergyPlus are isolated and individually tested. A solution strategy is proposed using the Energy Management System (EMS) capabilities within EnergyPlus. This solution strategy produces similar results to the other attic specific energy models. This paper shows that the current capabilities of EnergyPlus are sufficient to simulate radiant technologies in attics. The methodology showcased in this paper serves as a guide for engineers and researchers who would like to predict the performance radiant technology in attics using the whole building energy software, EnergyPlus.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Sustain: An experimental test bed for building energy simulation

Current building energy simulation technology requires extensive labor, time and expertise to create building energy models, substantial computational time for accurate simulations, and generates data in formats that make results difficult to interpret. These deficiencies can be ameliorated using modern graphical user interfaces and algorithms which take advantage of modern computer architectures and display capabilities. This paper describes a novel test bed environment which offers an interactive graphical interface, provides access to simulation modules that run at accelerated computational speeds, and presents new graphic visualization methods for the interpretation of simulation results. Its modular structure makes it suitable for use in early stage building design, for use as a research platform for the investigation of new simulation methods, and for use as a tool for teaching concepts of sustainable design. Improvements in the accuracy and execution speed of many of the simulation modules are based on the modification of advanced computer graphics rendering algorithms. Significant performance improvements are illustrated in several computationally expensive energy simulation modules.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Benefits of Dual Fuel Heat Pump Grid-responsive Control: A Model-based Control Optimization Approach Using Building and Equipment Co-simulation

Conventional dual fuel heat pumps lack the intelligent control mechanisms to efficiently manage the switch between heat pump and furnace, leading to sub-optimal energy usage and, in some cases, increased operating costs. To resolve this gap, this study applies optimized control on hybrid heat pumps. With a focus on equipment control strategies, we compare the performances of five spacing heating equipment, including a conventional heat pump (HP), a conventional furnace, a dual fuel heat pump (DFHP) with conventional control, a dual fuel heat pump with smart control, and a novel seamlessly fuel flexible heat pump (SFFHP). While DFHP runs on either gas or electricity at any given moment, SFFHP concurrently consumes gas and electricity by continuously optimizing the proportion of each. In this research, a co-simulation framework is developed by integrating a building envelope model with a physics-based heat pump simulation model to analyze the benefits of grid-responsive controls of DFHP and SFFHP. The model-based optimal controls adjust the operation of the heat pump and gas furnace based on utility price signals and marginal grid emission to minimize utility cost and CO 2 emissions for multiple climate zones, different utility tariffs, and marginal grid emission scenarios. Case studies in Chicago and Los Angeles demonstrate that SFFHP and DFHP, with model-based optimal control, can deliver significant reductions in peak demand, utility cost, and CO 2 emission. In Chicago, SFFHP and smart controlled DFHP yield up to 64.7% and 61.7% utility cost reduction and up to 15.7% and 8.5% CO 2 emission reduction compared to the gas furnace. In Los Angeles, SFFHP and smart controlled DFHP achieve up to 43.6% and 40.1% utility cost reduction and up to 13.8% and 14.1% CO2 emission reduction compared to conventional heat pumps. In conclusion, by leveraging the fuel flexibility nature of dual fuel heat pumps, the model-based control optimization approach makes dual fuel heat pump an attractive option for demand response programs.

Control↗

Expert Meeting: Recommended Approaches to Humidity Control in High Performance Homes

The topic of this Building America expert meeting was 'Recommended Approaches to Humidity Control in High Performance Homes,' which was held on October 16, 2012, in Westford, MA, and brought together experts in the field of residential humidity control to address modeling issues for dehumidification. The presentations and discussions centered on computer simulation and field experience with these systems, with the goal of developing foundational information to support the development of a Building America Measure Guideline on this topic.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Field Testing of Nano-PCM Enhanced Building Envelope Components

The U.S. Department of Energy's (DOE) Building Technologies Program s goal of developing high-performance, energy efficient buildings will require more cost-effective, durable, energy efficient building envelopes. Forty-eight percent of the residential end-use energy consumption is spent on space heating and air conditioning. Reducing envelope-generated heating and cooling loads through application of phase change material (PCM)-enhanced envelope components can facilitate maximizing the energy efficiency of buildings. Field-testing of prototype envelope components is an important step in estimating their energy benefits. An innovative phase change material (nano-PCM) was developed with PCM encapsulated with expanded graphite (interconnected) nanosheets, which is highly conducive for enhanced thermal storage and energy distribution, and is shape-stable for convenient incorporation into lightweight building components. During 2012, two test walls with cellulose cavity insulation and prototype PCM-enhanced interior wallboards were installed in a natural exposure test (NET) facility at Charleston, SC. The first test wall was divided into four sections, which were separated by wood studs and thin layers of foam insulation. Two sections contained nano-PCM-enhanced wallboards: one was a three-layer structure, in which nano-PCM was sandwiched between two gypsum boards, and the other one had PCM dispersed homogeneously throughout graphite nanosheets-enhanced gypsum board. The second test wall also contained two sections with interior PCM wallboards; one contained nano-PCM dispersed homogeneously in gypsum and the other was gypsum board containing a commercial microencapsulated PCM (MEPCM) for comparison. Each test wall contained a section covered with gypsum board on the interior side, which served as control or a baseline for evaluation of the PCM wallboards. The walls were instrumented with arrays of thermocouples and heat flux transducers. Further, numerical modeling of the walls containing the nano-PCM wallboards were performed to determine their actual impact on wall-generated heating and cooling loads. The models were first validated using field data, and then used to perform annual simulations using Typical Meteorological Year (TMY) weather data. This article presents the measured performance and numerical analysis to evaluate the energy-saving potential of the nano-PCM-enhanced building components.

nano-PCM↗

Numerical Study Of Melted Particles Crush Metallic Substrates And The Interaction Between Particles And A Plasma Beam In The Thermal Projection Process

Plasma spray processes have been widely used to produce high performance coatings of a wide range of Materials (metallic, non-metallic, ceramics), offering protection from, eg. wear, extreme temperature, chemical attack and environmental corrosion. To obtain good quality coatings, spray parameters must be carefully selected. Due to the large variety in process parameters, it is difficult to optimize the process for each specific coating and substrate combinations. Furthermore modelling the spray process allows a better understanding of the process sequences during thermal spraying. Good agreement of the virtual spraying process with the real coating formation is achieved by modelling the particular process steps. The simulation of coating formation to estimate the process parameters is an important tool to develop new coating structures with defined properties. In this work, the process of plasma sprayed coating has been analyzed by numerical simulation. Commercial code is used to predict the plasma jet characteristics, plasma--particle interaction, and coating formation. Using this model we can obtain coating microstructure and characteristics which form a foundation for further improvement of an advanced ceramic coating build up model.

36 MATERIALS SCIENCE↗

THE METALLICITY BIMODALITY OF GLOBULAR CLUSTER SYSTEMS: A TEST OF GALAXY ASSEMBLY AND OF THE EVOLUTION OF THE GALAXY MASS-METALLICITY RELATION

We build a theoretical model to study the origin of the globular cluster metallicity bimodality in the hierarchical galaxy assembly scenario. The model is based on empirical relations such as the galaxy mass-metallicity relation [O/H]-M {sub star} as a function of redshift, and on the observed galaxy stellar mass function up to redshift z {approx} 4. We make use of the theoretical merger rates as a function of mass and redshift from the Millennium simulation to build galaxy merger trees. We derive a new galaxy [Fe/H]-M {sub star} relation as a function of redshift, and by assuming that globular clusters share the metallicity of their original parent galaxy at the time of their formation, we populate the merger tree with globular clusters. We perform a series of Monte Carlo simulations of the galaxy hierarchical assembly, and study the properties of the final globular cluster population as a function of galaxy mass, assembly and star formation history, and under different assumptions for the evolution of the galaxy mass-metallicity relation. The main results and predictions of the model are the following. (1) The hierarchical clustering scenario naturally predicts a metallicity bimodality in the galaxy globular cluster population, where the metal-rich subpopulation is composed of globular clusters formed in the galaxy main progenitor around redshift z {approx} 2, and the metal-poor subpopulation is composed of clusters accreted from satellites, and formed at redshifts z {approx} 3-4. (2) The model reproduces the observed relations by Peng et al. for the metallicities of the metal-rich and metal-poor globular cluster subpopulations as a function of galaxy mass; the positions of the metal-poor and metal-rich peaks depend exclusively on the evolution of the galaxy mass-metallicity relation and the [O/Fe], both of which can be constrained by this method. In particular, we find that the galaxy [O/Fe] evolves linearly with redshift from a value of {approx}0.5 at redshift z {approx} 4 to a value of {approx}0.1 at z = 0. (3) For a given galaxy mass, the relative strength of the metal-rich and metal-poor peaks depends exclusively on the galaxy assembly and star formation history, where galaxies living in denser environments and/or early-type galaxies show a larger fraction of metal-poor clusters, while galaxies with a sparse merger history and/or late-type galaxies are dominated by metal-rich clusters. (4) The globular cluster metallicity bimodality disappears for galaxy masses around and below M {sub star} {approx} 10{sup 9} M {sub Sun }, and for redshifts z > 2.

79 ASTRONOMY AND ASTROPHYSICS↗

WaterTAP3 (The Water Technoeconomic Assessment Pipe-Parity Platform)

The Water Technoeconomic Assessment Pipe-Parity Platform (WaterTAP3) was developed under the National Alliance for Water Innovation (NAWI) to facilitate consistent technoeconomic assessments of desalination treatment trains. The WaterTAP3 is an analytically robust modeling tool that can be used to evaluate water technology cost, energy, environmental, and resiliency tradeoffs across different water sources, sectors, and scales. The model simulates steady-state water treatment train performance and costs including flow and constituent mass balance across unit processes, based on source water conditions, configurations of treatment technologies, and system-level techno-economic assumptions. Users can build a new treatment train by connecting any number of unit processes, specific for their context and system, or selecting a train from the treatment train library. The model contains various technical and cost parameter options for a range of treatment processes and a library of influent water quality characteristics for a variety of source waters and case studies. Users can customize water quality parameters to evaluate the technology performance in their context. The model can be set up for different assessment needs including simulation, optimization, and uncertainty and sensitivity analyses. The results from WaterTAP3 can help identify trade-offs among the different system performance metrics, with insight on how particular technologies or systems promote pipe-parity. The flexibility and comprehensive scope of the tool makes it a promising solution to industry-wide water technoeconomic evaluations, leading to more informed water investment decisions and technologies. As a user-friendly, open-source platform, WaterTAP3 can be used by industry, academia, policymakers, planners, and those with or without extensive analytical experience.

Miara, Ariel↗

Water Technoeconomic Assessment Pipe-Parity Platform (WaterTAP3)

The Water Technoeconomic Assessment Pipe-Parity Platform (WaterTAP3) was developed under the National Alliance for Water Innovation (NAWI) to facilitate consistent technoeconomic assessments of desalination treatment trains. The WaterTAP3 is an analytically robust modeling tool that can be used to evaluate water technology cost, energy, environmental, and resiliency tradeoffs across different water sources, sectors, and scales. The model simulates steady-state water treatment train performance and costs including flow and constituent mass balance across unit processes, based on source water conditions, configurations of treatment technologies, and system-level techno-economic assumptions. Users can build a new treatment train by connecting any number of unit processes, specific for their context and system, or selecting a train from the treatment train library. The model contains various technical and cost parameter options for a range of treatment processes and a library of influent water quality characteristics for a variety of source waters and case studies. Users can customize water quality parameters to evaluate the technology performance in their context. The model can be set up for different assessment needs including simulation, optimization, and uncertainty and sensitivity analyses. The results from WaterTAP3 can help identify trade-offs among the different system performance metrics, with insight on how particular technologies or systems promote pipe-parity. The flexibility and comprehensive scope of the tool makes it a promising solution to industry-wide water technoeconomic evaluations, leading to more informed water investment decisions and technologies. As a user-friendly, open-source platform, WaterTAP3 can be used by industry, academia, policymakers, planners, and those with or without extensive analytical experience. A publicly available graphical user interface is currently under development.

Miara, Ariel↗

Assessing the Potential of Active Insulation Systems to Reduce Energy Consumption and Enhance Electrical Grid Services

Building envelopes today act as passive systems in a dynamic environment. Traditional energy-saving efforts have mainly tried to improve the performance of building envelope systems by increasing thermal resistance to a set value that reduces energy flow. However, changes in weather and indoor conditions often lead to situations in which a low thermal resistance would decrease energy use. The optimization of thermal resistance that is triggered by changes in temperature, solar radiation, or availability of energy from renewable sources is currently not possible. Controllable active insulation systems (AISs), in which the thermal resistance of the insulation material can be dynamically controlled within a certain range, can expand the capabilities of the building envelope. With AISs the building envelope is no longer only a passive barrier between indoors and outdoors; instead, heat transfer can be controlled. Moreover, when AISs are combined with the thermal mass in the envelope system, these can act as thermal batteries that can be loaded and unloaded on demand. To quantify the benefits of AISs, a literature study of active insulation and achievable thermal conductivity ranges, thermal simulation models, and control logics was performed. Based on this literature study, a simulation model was developed to control the thermal resistance of insulation materials. A methodology to assess the potential of active insulation systems to reduce energy use and enhance electrical grid services was established and applied to identify ideal implementation scenarios for active insulation systems. A significant reduction of total building energy consumption for heating and cooling was found in all climate zones. The savings for the slab-on-ground DOE residential prototype building for eight selected cities in different climate zones range from 4069 kBtu to 8433 kBtu. Depending on the control cooling during peak load hours in Los Angeles could be reduced by more than 80% without a negative impact on thermal comfort conditions.

Antretter, Florian↗