Signatures of moiré trions in WSe 2 /MoSe 2 heterobilayers

Moiré superlattices formed by van der Waals materials can support a wide range of electronic phases, including Mott insulators superconductors and generalized Wigner crystals2. When excitons are confined by a moiré superlattice, a new class of exciton emerges, which holds promise for realizing artificial excitonic crystals and quantum optical effects. When such moiré excitons are coupled to charge carriers, correlated states may arise. However, no experimental evidence exists for charge-coupled moiré exciton states, nor have their properties been predicted by theory. In this work, we report the optical signatures of trions coupled to the moiré potential in tungsten diselenide/molybdenum diselenide heterobilayers. The moiré trions show multiple sharp emission lines with a complex charge-density dependence, in stark contrast to the behaviour of conventional trions. We infer distinct contributions to the trion emission from radiative decay in which the remaining carrier resides in different moiré minibands. Variation of the trion features is observed in different devices and sample areas, indicating high sensitivity to sample inhomogeneity and variability. The observation of these trion features motivates further theoretical and experimental studies of higher-order electron correlation effects in moiré superlattices.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Guest Editorial

The design of X-ray optical systems is very different from that of conventional optical systems, whether it be for the peculiarities of synchrotron radiation or the grazing incidence operation of most X-ray optical components. Further, specific simulation tools are thus required to ensure that designs work as expected, and there is now a vibrant landscape of open-source, freely available software that can be used to that end, and explore new design concepts.

47 OTHER INSTRUMENTATION↗

Refractive Guide Switching a Regenerative Amplifier Free-Electron Laser for High Peak and Average Power Hard X Rays

In this work, we present an x-ray regenerative amplifier free-electron laser design capable of producing fully coherent hard x-ray pulses across a broad tuning range at a high steady state repetition rate. The scheme leverages a strong undulator taper and an apertured diamond output-coupling cavity crystal to produce both high peak and average spectral brightness radiation that is 2 to 3 orders of magnitude greater than conventional single-pass self-amplified spontaneous emission free-electron laser amplifiers. Refractive guiding in the postsaturation regime is found to play a key role in passively controlling the stored cavity power. The scheme is explored both analytically and numerically in the context of the Linac Coherent Light Source II High Energy upgrade.

47 OTHER INSTRUMENTATION↗

Photon energy-modulated radiotherapy: Monte Carlo simulation and treatment planning study

Purpose: To demonstrate the feasibility of photon energy-modulated radiotherapy during beam-on time. Methods: A cylindrical device made of aluminum was conceptually proposed as an energy modulator. The frame of the device was connected with 20 tubes through which mercury could be injected or drained to adjust the thickness of mercury along the beam axis. In Monte Carlo (MC) simulations, a flattening filter of 6 or 10 MV linac was replaced with the device. The thickness of mercury inside the device varied from 0 to 40 mm at the field sizes of 5 x 5 cm{sup 2} (FS5), 10 x 10 cm{sup 2} (FS10), and 20 x 20 cm{sup 2} (FS20). At least 5 billion histories were followed for each simulation to create phase space files at 100 cm source to surface distance (SSD). In-water beam data were acquired by additional MC simulations using the above phase space files. A treatment planning system (TPS) was commissioned to generate a virtual machine using the MC-generated beam data. Intensity modulated radiation therapy (IMRT) plans for six clinical cases were generated using conventional 6 MV, 6 MV flattening filter free, and energy-modulated photon beams of the virtual machine. Results: As increasing the thickness of mercury, Percentage depth doses (PDD) of modulated 6 and 10 MV after the depth of dose maximum were continuously increased. The amount of PDD increase at the depth of 10 and 20 cm for modulated 6 MV was 4.8% and 5.2% at FS5, 3.9% and 5.0% at FS10 and 3.2%-4.9% at FS20 as increasing the thickness of mercury from 0 to 20 mm. The same for modulated 10 MV was 4.5% and 5.0% at FS5, 3.8% and 4.7% at FS10 and 4.1% and 4.8% at FS20 as increasing the thickness of mercury from 0 to 25 mm. The outputs of modulated 6 MV with 20 mm mercury and of modulated 10 MV with 25 mm mercury were reduced into 30%, and 56% of conventional linac, respectively. The energy-modulated IMRT plans had less integral doses than 6 MV IMRT or 6 MV flattening filter free plans for tumors located in the periphery while maintaining the similar quality of target coverage, homogeneity, and conformity. Conclusions: The MC study for the designed energy modulator demonstrated the feasibility of energy-modulated photon beams available during beam-on time. The planning study showed an advantage of energy-and intensity modulated radiotherapy in terms of integral dose without sacrificing any quality of IMRT plan.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Search for a Close-Mass Lepton Doublet

Described is a search for a heavy charged lepton with an associated neutrino of nearly the same mass, together known as a close-mass lepton doublet. The search is conducted in e + e - annihilation data taken with the Mark II detector at a center-of- mass energy of 29 GeV. In order to suppress contamination from conventional two-photon reactions, the search applies a novel, radiative-tagging technique. Requiring the presence of an isolated, energetic photon allows exploration for lepton doublets with a mass splitting smaller than that previously accessible to experiment. No evidence for such a new lepton has been found, enabling limits to be placed on allowed mass combinations. Mass differences as low as 250-300 MeV are excluded for charged lepton masses up to 10 GeV.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Impact of buildings on surface solar radiation over urban Beijing

The rugged surface of an urban area due to varying buildings can interact with solar beams and affect both the magnitude and spatiotemporal distribution of surface solar fluxes. Here we systematically examine the impact of buildings on downward surface solar fluxes over urban Beijing by using a 3-D radiation parameterization that accounts for 3-D building structures vs. the conventional plane-parallel scheme. We find that the resulting downward surface solar flux deviations between the 3-D and the plane-parallel schemes are generally ±1–10 W m -2 at 800 m grid resolution and within ±1 W m -2 at 4 km resolution. Pairs of positive–negative flux deviations on different sides of buildings are resolved at 800 m resolution, while they offset each other at 4 km resolution. Flux deviations from the unobstructed horizontal surface at 4 km resolution are positive around noon but negative in the early morning and late afternoon. The corresponding deviations at 800 m resolution, in contrast, show diurnal variations that are strongly dependent on the location of the grids relative to the buildings. Both the magnitude and spatiotemporal variations of flux deviations are largely dominated by the direct flux. Furthermore, we find that flux deviations can potentially be an order of magnitude larger by using a finer grid resolution. Atmospheric aerosols can reduce the magnitude of downward surface solar flux deviations by 10–65 %, while the surface albedo generally has a rather moderate impact on flux deviations. The results imply that the effect of buildings on downward surface solar fluxes may not be critically significant in mesoscale atmospheric models with a grid resolution of 4 km or coarser. However, the effect can play a crucial role in meso-urban atmospheric models as well as microscale urban dispersion models with resolutions of 1 m to 1 km.

54 ENVIRONMENTAL SCIENCES↗

The collective excitation of g-modes in the sun

Oscillations of the solar interior (linear g-modes) may be strongly driven by the collective influence of all the modes upon the nuclear reactions in the core. This heretofore neglected effect could couple the modes, reduce the effective amplitudes near the center, and spatially concentrate most of the oscillation energy into just a portion of the radiative interior. If operating at sufficient strength, this can reverse the conventional conclusion, drawn from single mode calculations, that almost all solar g-modes are damped. Furthermore, it would put the theory into rough harmony with three otherwise troubling observations: (1) the 'low' neutrino flux measured by Davis (1978), (2) the high correspondence found by Wolff (1976) between recurrence periods in solar activity and the rotational beat periods of g-modes, and (3) the fluctuations in the sun's diameter which imply g-mode activity at high angular harmonics (Hill and Caudell 1979). A nonlinear expression is derived for the local rate of work done on an array of oscillation modes by the nuclear reactions. Three additional tests of the model are suggested.

Wolff, C. L.↗

Thermal management of high power space based systems

Conventional techniques of using a portion of the spacecraft skin for radiation of waste heat will be inadequate for high powered payloads (50 to 100 kWe) due to the lack of sufficient area. A Shuttle type system using a pumped single phase fluid loop could be scaled up to higher power but this type of system would require excessive pump power and weight. A pumped two-phase heat transfer loop has a much lower pumping requirement due to the higher latent heat of vaporization of the fluid in comparison to the sensible heat it can absorb through a temperature change. Concepts for an evaporator and a condenser for a pumped two-phase system are described. The condenser uses capillary grooves and a separate pumped condensate return line to achieve high heat transfer coefficients and stable operation due to the separation of the vapor and liquid flows. The cold plate evaporator uses wicks to contain the liquid and transport it to the heated surface. It can also function as a condenser for warming components. Control concepts for the cold plate are discussed. Concepts for deployment or erection of large space radiators are also considered.

Hwangbo, H.↗

Fluorescence spectroscopy and thermometry for hypersonic flight research

The present study, which has demonstrated the feasibility of using time-resolved laser-induced fluorescence methods to ascertain boundary layer temperature distributions in real time for hypersonic vehicles in atmospheric flight, employs conventional optics in combination with novel time-resolved spectroscopy. The radiative lifetime and signal intensity involved, both of which are reduced by quenching, are adequate for measurement with state-of-the-art time-resolved fluorescence techniques, except for certain conditions associated with both the highest speeds and the lowest altitudes.

Thompson, B. E.↗

Canceling Torque Caused By Boiloff Of Cryogen

Proposed technique for cancellation of small torques caused by venting of cryogens from tanks in spacecraft adaptable to use in making small corrections in orientations of terrestrial scientific instruments. Torque eliminated by directing exhaust gas through "T" vent. To cancel remaining small torque, that side of "T" from which exhaust produces smaller thrust heated just enough to equalize opposing thrusts. Concept useful in situations in which conventional electromagnetic actuators not suitable because of constraints related to temperature, radiation, or vibration and equipment required to be robust, simple, reliable, light in weight, and without moving parts.

Bhandari, Pradeep↗

Polymer Coats Leads on Implantable Medical Device

Langley Research Center s Soluble Imide (LaRC-SI) was discovered by accident. While researching resins and adhesives for advanced composites for high-speed aircraft, Robert Bryant, a Langley engineer, noticed that one of the polymers he was working with did not behave as predicted. After putting the compound through a two-stage controlled chemical reaction, expecting it to precipitate as a powder after the second stage, he was surprised to see that the compound remained soluble. This novel characteristic ended up making this polymer a very significant finding, eventually leading Bryant and his team to win several NASA technology awards, and an "R&D 100" award. The unique feature of this compound is the way that it lends itself to easy processing. Most polyimides (members of a group of remarkably strong and incredibly heat- and chemical-resistant polymers) require complex curing cycles before they are usable. LaRC-SI remains soluble in its final form, so no further chemical processing is required to produce final materials, like thin films and varnishes. Since producing LaRC-SI does not require complex manufacturing techniques, it has been processed into useful forms for a variety of applications, including mechanical parts, magnetic components, ceramics, adhesives, composites, flexible circuits, multilayer printed circuits, and coatings on fiber optics, wires, and metals. Bryant s team was, at the time, heavily involved with the aircraft polymer project and could not afford to further develop the polymer resin. Believing it was worth further exploration, though, he developed a plan for funding development and submitted it to Langley s chief scientist, who endorsed the experimentation. Bryant then left the high-speed civil transport project to develop LaRC-SI. The result is an extremely tough, lightweight thermoplastic that is not only solvent-resistant, but also has the ability to withstand temperature ranges from cryogenic levels to above 200 C. The thermoplastic s unique characteristics lend it to many commercial applications; uses that Bryant believed would ultimately benefit industry and the Nation. "LaRC-SI," he explains, "is a product created in a government laboratory, funded with money from the tax-paying public. What we discovered helps further the economic competitiveness of the United States, and it was our goal to initiate the technology transfer process to ensure that our work benefited the widest range of people." Several NASA centers, including Langley, have explored methods for using LaRC-SI in a number of applications from radiation shielding and as an adhesive to uses involving replacement of conventional rigid circuit boards. In the commercial realm, LaRC-SI can now be found in several commercial products, including the thin-layer composite unimorph ferroelectric driver and sensor (THUNDER) piezoelectric actuator, another "R&D 100" award winner (Spinoff 2005).

Source record↗

Nuclear Thermal Propulsion: Past, Present, and a Look Ahead

NTR: High thrust high specific impulse (2 x LOXLH2 chemical) engine uses high power density fission reactor with enriched uranium fuel as thermal power source. Reactor heat is removed using H2 propellant which is then exhausted to produce thrust. Conventional chemical engine LH2 tanks, turbo pumps, regenerative nozzles and radiation-cooled shirt extensions used -- NTR is next evolutionary step in high performance liquid rocket engines.

Nuclear rocket engines↗

Surface Passivation by Quantum Exclusion Using Multiple Layers

A semiconductor device has a multilayer doping to provide improved passivation by quantum exclusion. The multilayer doping includes at least two doped layers fabricated using MBE methods. The dopant sheet densities in the doped layers need not be the same, but in principle can be selected to be the same sheet densities or to be different sheet densities. The electrically active dopant sheet densities are quite high, reaching more than 1.times.10.sup.14 cm.sup.-2, and locally exceeding 10.sup.22 per cubic centimeter. It has been found that silicon detector devices that have two or more such dopant layers exhibit improved resistance to degradation by UV radiation, at least at wavelengths of 193 nm, as compared to conventional silicon p-on-n devices.

Hoenk, Michael E.↗

Electric Motor Noise from Small Quadcopters: Source Characteristics - Part II

The increased interest in electric motors for propulsion systems has driven interest in quantifying the contribution of electric motor noise to the overall sound levels and possible human annoyance of the propulsion system. This work presents acoustic measurements of electric motors used for small quadcopters to quantify the sound produced by a number of outrunning motors with different types of controllers. Results are presented for loaded and unloaded motors as installed and uninstalled configurations. Motor resonance frequencies were measured and computed. Current probe measurements showed that the supply current from the controllers contained significant harmonic content for the conventional and sinewave controllers. Acoustic results showed motor noise is typically radiated at frequencies near the mode 2 vibration frequency at roughly 5000 Hz. Electric motor noise was evident in the spectra produced by many of the motor-controller combinations for motors loaded with propellers with levels often greater than those for the motor alone due to increase in the stator magnetic flux density with increased current. An installed configuration produced increases in acoustic radiation over that of the uninstalled motor in a frequency range near the mode 1 vibration frequency near 1200 Hz. A companion paper (Part I - Acoustic Measurements), focuses on source identification using a phased array and directivity characteristics for a baseline configuration.

Motor Resonance Frequencies↗

Electric Motor Noise from Small Quadcopters: Part II - Source Characteristics

The increased interest in electric motors for aircraft propulsion systems has driven interest in quantifying the contribution of electric motor noise to the overall sound levels and possibly human annoyance of the propulsion system. This work presents acoustic measurements of electric motors used for small quadcopters to quantify the sound produced by a number of outrunner motors with different types of controllers. Results are presented for loaded and unloaded motors as well as installed and uninstalled configurations. Motor resonance frequencies were measured and computed. Current probe measurements showed significant harmonic content in the supply current from the controllers for both the conventional and sinewave controllers. Acoustic results showed motor noise is typically radiated at frequencies near that for azimuthal vibration mode number 2 of the rotor which occurs at roughly 5000 Hz. Electric motor noise was evident in the spectra produced by many of the motor-controller combinations for motors loaded with propellers with levels often greater than those for the motor alone due to increases in the stator magnetic flux density with increased current. An installed quadcopter configuration produced increases in acoustic radiation over that of the uninstalled motor in a frequency range near the 1200 Hz azimuthal vibration mode 1 of the rotor.

Henderson, Brenda↗

Electrophysiological Monitoring in Patients With Tumors of the Skull Base Treated by Carbon-12 Radiation Therapy

Purpose: To report the results of short-term electrophysiologic monitoring of patients undergoing {sup 12}C therapy for the treatment of skull chordomas and chondrosarcomas unsuitable for radical surgery. Methods and Materials: Conventional electroencephalogram (EEG) and retinal and cortical electrophysiologic responses to contrast stimuli were recorded from 30 patients undergoing carbon ion radiation therapy, within a few hours before the first treatment and after completion of therapy. Methodologies and procedures were compliant with the guidelines of the International Federation for Clinical Neurophysiology and International Society for Clinical Electrophysiology of Vision. Results: At baseline, clinical signs were reported in 56.6% of subjects. Electrophysiologic test results were abnormal in 76.7% (EEG), 78.6% (cortical evoked potentials), and 92.8% (electroretinogram) of cases, without correlation with neurologic signs, tumor location, or therapy plan. Results on EEG, but not electroretinograms and cortical responses, were more often abnormal in patients with reported clinical signs. Abnormal EEG results and retinal/cortical responses improved after therapy in 40% (EEG), 62.5% (cortical potentials), and 70% (electroretinogram) of cases. Results on EEG worsened after therapy in one-third of patients whose recordings were normal at baseline. Conclusions: The percentages of subjects whose EEG results improved or worsened after therapy and the improvement of retinal/cortical responses in the majority of patients are indicative of a limited or negligible (and possibly transient) acute central nervous system toxicity of carbon ion therapy, with a significant beneficial effect on the visual pathways. Research on large samples would validate electrophysiologic procedures as a possible independent test for central nervous system toxicity and allow investigation of the correlation with clinical signs; repeated testing over time after therapy would demonstrate, and may help predict, possible late toxicity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Real-time fast inverse dose optimization for image guided adaptive radiation therapy-Enhancements to fast inverse dose optimization (FIDO)

A fast, accurate and stable optimization algorithm is very important for inverse planning of intensity-modulated radiation therapy (IMRT), and for implementing dose-adaptive radiotherapy in the future. Conventional numerical search algorithms with positive beam weight constraints generally require numerous iterations and may produce suboptimal dose results due to trapping in local minima regions of the objective function landscape. A direct solution of the inverse problem using conventional quadratic objective functions without positive beam constraints is more efficient but it will result in unrealistic negative beam weights. We review here a direct solution of the inverse problem that is efficient and does not yield unphysical negative beam weights. In fast inverse dose optimization (FIDO) method the objective function for the optimization of a large number of beamlets is reformulated such that the optimization problem is reducible to a linear set of equations. The optimal set of intensities is then found through a matrix inversion, and negative beamlet intensities are avoided without the need for externally imposed ad hoc conditions. In its original version [S. P. Goldman, J. Z. Chen, and J. J. Battista, in Proceedings of the XIVth International Conference on the Use of Computers in Radiation Therapy, 2004, pp. 112-115; S. P. Goldman, J. Z. Chen, and J. J. Battista, Med. Phys. 32, 3007 (2005)], FIDO was tested on single two-dimensional computed tomography (CT) slices with sharp KERMA beams without scatter, in order to establish a proof of concept which demonstrated that FIDO could be a viable method for the optimization of cancer treatment plans. In this paper we introduce the latest advancements in FIDO that now include not only its application to three-dimensional volumes irradiated by beams with full scatter but include as well a complete implementation of clinical dose-volume constraints including maximum and minimum dose as well as equivalent uniform dose constraints. The method has been integrated into a commercial treatment planning system (Pinnacle, Philips Medical Systems) for beta testing using clinical radiotherapy cases and standard dose constraints set by radiation oncologists. Our FIDO method consistently delivered excellent treatment plans comparable and often better than those obtained using standard optimization techniques that are considerably slower. By design, FIDO is guaranteed to find a global minimum and will achieve highly conformal and homogeneous dose distributions without the need for artificial internal contours that must be created in conventional IMRT optimization systems to help the search engines better control some beam entry directions and in this way avoid the creation of hot and cold spots. This method provides a fast, intuitive and robust technique that yields excellent results for the inverse planning of IMRT. FIDO's ability to efficiently optimize very large numbers of beamlet weights also makes it an ideal tool for the optimization of helical tomotherapy. Future gains in speed will make it possible to use FIDO for instant treatment plan reoptimization using CT images produced at the radiotherapy machine, just prior to daily treatments of the patient.

61 RADIATION PROTECTION AND DOSIMETRY↗