Search NASA⌕ Search

SEARCH · Search NASA

Results for “CORROSION CONTROL”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Ultra-thin g-C{sub 3}N{sub 4} nanosheets wrapped silicon nanowire array for improved chemical stability and enhanced photoresponse

Highlights: • g-C{sub 3}N{sub 4}, as an oxygen free and metal free protective material for Si, was proposed. • g-C{sub 3}N{sub 4} nanosheets wrapped Si nanowire array was synthesized. • SiNW/g-C{sub 3}N{sub 4} exhibited enhancement of photoelectrochemical stability and photocurrent. - Abstract: In order to inhibit the oxidation of Si materials in aqueous solution, Si nanowire array was wrapped by ultra-thin g-C{sub 3}N{sub 4} nanosheets via an electrophoresis process. Scanning electron microscopy and transmission electron microscopy images showed that g-C{sub 3}N{sub 4} nanosheets were evenly distributed on the surface of Si nanowire array. X-ray diffraction patterns indicated that Si nanowire array/g-C{sub 3}N{sub 4} nanosheets were composed of Si (4 0 0 crystal plane) and g-C{sub 3}N{sub 4} (0 0 2 and 1 0 0 crystal planes). The cyclic voltammetry curves revealed that the corrosion of Si nanowire array was restrained under the protection of g-C{sub 3}N{sub 4} nanosheets. Furthermore, the photocurrent density of Si nanowire array/g-C{sub 3}N{sub 4} nanosheets increased by nearly 3 times compared to that of bare Si nanowire array due to the effective charge separation caused by the built-in electric field at the interface. This work will facilitate the applications of Si materials in aqueous solution, such as solar energy harvest and photocatalytic pollution control.

36 MATERIALS SCIENCE↗

Effects of transient thermal shock on the microstructures and corrosion properties of a reduced activation high-entropy alloy

The devices would subject transient thermal shocks (TTS) during operation under extremely harsh conditions of nuclear fusion reactors, which inevitably exert significant impact on the microstructure and performance of structural materials. Here, a reduced activation VCrFeTa 0.2 W 0.2 high-entropy alloy (HEA) was developed by vacuum arc melting. The effects of electron beam induced TTS on its microstructure, microhardness, and corrosion properties were investigated. The results indicate that the weight fraction of each phase changes after TTS, showing a significant decrease in the content of BCC1 phase and an increase in the content of BCC2 and Laves phases. The content of BCC1 phase continues to decrease slightly with increasing the power of TTS. Besides, the microhardness of the alloy increases from ~673 HV to ~714 HV after TTS treatments. In the reduced activation HEA, TTS results in a relatively low corrosion current density of ~0.472 μA/cm 2 in 3.5 wt% NaCl solution, around one-third of the current density observed in the as-cast sample. Furthermore, the VCrFeTa 0.2 W 0.2 HEA after TTS exhibits a pitting potential of ~1.165 V SCE , which is much higher than that of the as-cast sample. The refined composite multiscale entropy method is employed to analyze the influence of TTS on current fluctuation behavior during the corrosion process. The reduced activation VCrFeTa 0.2 W 0.2 HEA exhibits excellent properties in harsh environments after TTS, thereby showing advantageous property in the field of nuclear structural materials. Furthermore, TTS is an efficient and controllable strategy for the improvement of the HEAs’ microstructures and performances.

36 MATERIALS SCIENCE↗

Validating corrosion models: Influence of physical properties

In chloride containing environments, two metals in physical contact can undergo galvanic corrosion limiting the lifetime of components. Being able to accurately predict galvanic corrosion damage distributions over time has not been widely presented in literature. Therefore, Finite Element Method (FEM) corrosion models were experimentally validated for two galvanic couples as a function of governing equations, environment, anode material, anode:cathode ratio, and time. Carbon steel/stainless steel (CS/SS) and zinc/stainless steel (Zn/SS) galvanic couples were exposed to NaCl solutions at room temperatures for up to 14 days. For the galvanic couples and environments, the Laplace equation with variable conductivity and reactions was sufficient to model the experimental corrosion damage. Increasing the chloride concentration for the CS/SS galvanic couple, regardless of the anode:cathode ratio, decreased the observed and modeled corrosion damage. Decreasing the anode:cathode ratio (i.e., increasing the cathode length), increased the experimentally observed and modeled corrosion damage. For small anode:cathode ratios, the governing equations deviate over long time periods with the Nernst-Plank equation being conservative. For the Zn/SS galvanic couple, the cathode length controls the dominant cathodic reduction reaction. For small cathode lengths, the hydrogen evolution reaction is dominant. For larger cathode lengths, the oxygen reduction reaction is dominant. The results are discussed with regard to the influence of solution chemistry, ohmic drop, and governing reactions. Overall, validated FEM models were presented, and the resultant models, physics, and mechanisms can be applied to other corrosion scenarios with confidence.

Carbon steel↗

Electrochemical, Polarization, and Crevice Corrosion Testing of Nitinol 60, A Supplement to the ECLSS Sustaining Materials Compatibility Study

In earlier trials, electrochemical test results were presented for six noble metals evaluated in test solutions representative of waste liquids processed in the Environmental Control and Life Support System (ECLSS) aboard the International Space Station (ISS). Subsequently, a seventh metal, Nitinol 60, was added for evaluation and subjected to the same test routines, data analysis, and theoretical methodologies. The previous six test metals included three titanium grades, (commercially pure, 6Al-4V alloy and 6Al-4V low interstitial alloy), two nickel-chromium alloys (Inconel(RegisteredTrademark) 625 and Hastelloy(RegisteredTrademark) C276), and one high-tier stainless steel (Cronidur(RegisteredTrademark) 30). The three titanium alloys gave the best results of all the metals, indicating superior corrosive nobility and galvanic protection properties. For this current effort, the results have clearly shown that Nitinol 60 is almost as noble as titanium, being very corrosion-resistant and galvanically compatible with the other six metals electrochemically and during long-term exposure. is also quite noble as it is very corrosion resistant and galvanically compatible with the other six metals from both an electrochemical perspective and long-term crevice corrosion scenario. This was clearly demonstrated utilizing the same techniques for linear, Tafel and cyclic polarization, and galvanic coupling of the metal candidate as was done for the previous study. The high nobility and low corrosion susceptibility for Nitinol 60 appear to be intermediate to the nickel/chromium alloys and the titanium metals with indications that are more reflective of the titanium metals in terms of general corrosion and pitting behavior.

Lee, R. E.↗

Effects of porosity on corrosion resistance of Mg alloy foam produced by powder metallurgy technology

Magnesium alloy foams have the potential to serve as structural material for regular light-weight applications as well as for biodegradable scaffold implants. However, their main disadvantage relates to the high reactivity of magnesium and consequently their natural tendency to corrode in regular service conditions and in physiological environments. The present study aims at evaluating the effect of porosity on the corrosion resistance of MRI 201S magnesium alloy foams in 0.9% NaCl solution and in phosphate buffer saline solution as a simulated physiological electrolyte. The magnesium foams were produced by powder metallurgy technology using space-holding particles to control the porosity content. Machined chips were used as raw material for the production of Mg alloy powder by milling process. The microstructure of the foams was examined using optical and scanning electron microscopy, X-ray diffraction, and X-ray photoelectron spectroscopy analysis. The corrosion behavior was evaluated by immersion test and potentiodynamic polarization analysis. The results obtained clearly demonstrate that the porosity has a significant effect on the corrosion resistance of the tested foams. Foams with 14–19% porosity have a corrosion rate of 4–10 mcd and 7–15 mcd in NaCl and phosphate buffer saline solution, respectively, compared to only 0.10 mcd for the same alloy in as cast conditions. This increased corrosion degradation of the Mg foams by more than one order of magnitude compared to the cast alloy may limit their potential application in regular and physiological environments. - Highlights: • Porosity has a detrimental effect on corrosion resistance of MRI 201S Mg foams. • 14–19% porosity increases the corrosion rate by more than one order of magnitude. • Accelerated corrosion limits the use of foams in regular/physiological environments.

36 MATERIALS SCIENCE↗

Re-establishment of Sandia National Labs super-critical carbon dioxide testing autoclave capability for exposure of metal alloys and polymers (Level 4 Milestone Report)

The sCO 2 system located in 916/160A, Sandia National Laboratories, CA, was constructed in 2014, for testing of materials in the presence of supercritical carbon dioxide (sCO 2 ) at high pressures (up to 3500 psi) and temperatures (up to 650°C). The basic design of the system consists of a thermally insulated IN625 autoclave, a high-pressure supercritical CO 2 compressor, autoclave heaters, temperature controllers, gas manifold, and temperature and pressure diagnostics. This system was modified in 2016 (sCO 2 compressor was removed) to enable corrosion studies with metal alloys in gaseous CO 2 at lower pressure (up to 300 psi) at 500°C. The capability was not used much afterwards until 2020, when preliminary tests using this capability (again without the supercritical CO 2 compressor) involved the exposure of fatigue and tensile specimens of HN 230 and 800H alloys to CO 2 gas for 168 hours in gaseous CO 2 . Using this capability, we finished experiments with low pressure (450 psi/ 3 MPa), high temperature (650°C) exposure of fatigue and tensile specimens of HN 230 and 800H alloys to CO 2 gas for 168 hours. The data from these experiments will be compared to that gathered from experiments performed in 2020 using the tube furnace and presented in a future report. It is to be noted that the tube furnace experiments ran 500-1500 hours, unlike the 168 hours of exposure in the recent experiment. This can help validate the use of the sCO 2 autoclave for both CO 2 and sCO 2 experiments.

36 MATERIALS SCIENCE↗

Thermal Characterization of Defects in Aircraft Structures Via Spatially Controlled Heat Application

Recent advances in thermal imaging technology have spawned a number of new thermal NDE techniques that provide quantitative information about flaws in aircraft structures. Thermography has a number of advantages as an inspection technique. It is a totally noncontacting, nondestructive, imaging technology capable of inspecting a large area in a matter of a few seconds. The development of fast, inexpensive image processors have aided in the attractiveness of thermography as an NDE technique. These image processors have increased the signal to noise ratio of thermography and facilitated significant advances in post-processing. The resulting digital images enable archival records for comparison with later inspections thus providing a means of monitoring the evolution of damage in a particular structure. The National Aeronautics and Space Administration's Langley Research Center has developed a thermal NDE technique designed to image a number of potential flaws in aircraft structures. The technique involves injecting a small, spatially controlled heat flux into the outer surface of an aircraft. Images of fatigue cracking, bond integrity and material loss due to corrosion are generated from measurements of the induced surface temperature variations. This paper will present a discussion of the development of the thermal imaging system as well as the techniques used to analyze the resulting thermal images. Spatial tailoring of the heat coupled with the analysis techniques represent a significant improvement in the delectability of flaws over conventional thermal imaging. Results of laboratory experiments on fabricated crack, disbond and material loss samples will be presented to demonstrate the capabilities of the technique. An integral part of the development of this technology is the use of analytic and computational modeling. The experimental results will be compared with these models to demonstrate the utility of such an approach.

Cramer, K. Elliott↗

Ab-Initio Simulation Studies of Cr Solvation in Fluoride Molten Salts

Understanding molten salt chemistry is essential in ongoing research of the molten salt nuclear reactor (MSR). In this context, detailed understanding of the mechanisms underlying selective oxidation of metal species, such as Cr, is required to guide the design of effective corrosion mitigation strategies in molten salts. An important starting point for such mechanistic understanding is knowledge of the solvation structure and its role in controlling metal speciation. In this work, we use ab initio molecular dynamics simulations to study the short-range (on the scale of the nearest-neighbor bond lengths) and medium-range (over length scales of several neighbor spacings) structure in three different fluoride melts with and without Cr addition; namely, 2KF-NaF, 2LiF-BeF 2 , and 3LiF-AlF3. We find that Cr 0 ,Cr 2+ ,Cr 3+ can each be coordinated by different numbers of F-, with the variance in coordination number decreasing as oxidation state increases, and that these coordination geometries are largely independent of solvent. The manner by which Cr changes the medium-range structure, however, is found to be solvent-dependent. While 2KF-NaF melts show short and medium range order that is highly dynamic, 2LiF-BeF 2 and 3LiF-AlF 3 are characterized by molecular associates that are relatively long-lived that organize into oligomer structures on larger length scales. Rather than being solvated by F- ions alone, we find that Cr can incorporate into and be solvated within this oligomer structure. Fluoroacidity, alone, may therefore prove too simple a metric for assessing the corrosivity of molten fluorides. As our work suggests, the ability of Cr to solvate must be understood in the context of the short- and medium-range structure of the solvent.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Effectiveness of Vapor Corrosion Inhibitors Under Bacterial Activity for Aboveground Storage Tank Application

Bacterial activity is known to influence corrosion and can result in increasing soil-side corrosion of the aboveground storage tanks (ASTs) floor plates. Association for Materials Protection and Performance (AMPP) defines this phenomenon as Microbiologically Influenced Corrosion (MIC). It has been hypothesized that vapor corrosion inhibitors (VCIs) can not only function in presence of bacterial activity but can also function as biocides. Experiments were conducted to study the effect of bacterial activity on corrosion in the sand pad conditions and effect of VCIs in mitigating MIC. Various bacteria cultures were grown using commercially available culture media, and coupon exposure tests were performed with field sand mixed with the culture media. To this end, control and VCI-dosed electrolytes were prepared using the field sand plus bacteria cultures. Pre- and post-test bacteria concentration estimation and measurements, respectively, in the VCI-dosed electrolytes indicated that VCIs do not function as biocides, however, VCIs are highly effective for mitigating corrosion in presence of bacterial activity.

Shukla, Pavan K.↗

High-temperature Tribological Behavior of Structural Materials after Conditioning in Impure-Helium Environments for High_temperature Gas-Cooled Reactor Applications

Incoloy 800HT and Inconel 617 have been selected as candidate structural alloys for the hightemperature gas-cooled reactor (HTGR) concept. Helium, the primary coolant, contains impurities (e.g., H2O and CH4) that can induce corrosion reactions at high temperatures, which in turn can affect the tribological behavior of components in sliding contact such as valves and control-rod drive systems. This paper presents results from the study of the tribological behavior of both alloys before and after conditioning them in either an impure-helium oxidizing environment or in an air environment. Both alloys were conditioned for 22 days at elevated temperatures in a once-through helium loop with 4 ppmv H2O and tested subsequently at elevated temperatures with a pin-on-disk tribometer in an air environment 650 degrees C and 750 degrees C for 800HT; 850 degrees C and 900 degrees C for 617 - with various applied loads - 1 N, 2 N and 5 N. SEM-EDS analysis revealed that conditioning the samples in an oxidizing environment leads to the formation of a mixed Fe/Cr-oxide on alloy 800HT and a Cr-oxide on alloy 617, both increasing the wear resistance compared to that of as-received samples. Alloy 617 exhibited lower steady-state friction coefficients compared to those of alloy 800HT. There was a significant decrease in the scatter of the steadystate friction coefficient of the conditioned samples compared to that of the unconditioned samples. The steady-state friction coefficient for alloy 800HT and 617 were found to be 0.53 +/- 0.07 and 0.25 +/- 0.04, respectively. The wear resistance of alloy 800HT is approximately one order of magnitude lower than that of alloy 617 in all cases that exhibited measurable wear. After sample conditioning, the wear volumes measured at low loads were undistinguishable from the unworn background, a result attributed to the formation of a compacted glaze layer under high temperatures and high contact stresses.

Alloys 800 and 617↗

Geo-Responsive Chemomechanics in Aluminum Oxyhydroxide via Alkali-Driven Dehydroxylation for Supercritical Geothermal Systems

Widespread use of enhanced geothermal systems can revolutionize global renewable electrical power access, yet its advancement is hindered by the inherent instability of Portland cement-based chemistries for geothermal well construction under high-temperature corrosive conditions. Here, in this work, we demonstrate the tunable mechanical performance of aluminum oxyhydroxides as cementitious materials through an alkali-controlled dehydroxylation reaction pathway for long-term applications under supercritical geothermal environments. Notably, the synthesized aluminum oxyhydroxides demonstrate remarkable stability, maintaining superior mechanical performance under supercritical conditions for over 30 days. Synchrotron X-ray diffraction, spectroscopy measurements and geochemical thermodynamic modeling uncover that the gibbsite dehydroxylation pathway functions as a key dial for tuning the chemomechanics, rendering the aluminum oxyhydroxide a strong cementitious material. By uncovering the mechanistic role of alkali-driven dehydroxylation, this work proposes a cementitious chemistry distinct from conventional Portland cement and geopolymer-dominated alkali-activated systems, laying the groundwork for developing next-generation cementitious materials for supercritical geothermal energy exploitation.

15 GEOTHERMAL ENERGY↗

Oxygen-hydrogen torch is a small-scale steam generator

Standard oxygen-hydrogen torch generates steam for corrosion-rate analysis of various metals. The steam is generated through local combustion inside a test chamber under constant temperature and pressure control.

Maskell, C. E.↗

Metallurgical characterization of the fracture of aluminum alloys

A systematic investigation was conducted to examine the fracture behavior of the structural aluminum alloys 2024, 6061, 7075, and 7178 (in selected heat treatments) tested under several controlled conditions. The investigation included both time independent (tensile, shear, and precracked notch-bend) fractures and time dependent (fatigue and stress corrosion) fractures. Specimens were obtained from both sheet and plate material and tested in longitudinal and transverse orientations. Strain rate effects on fracture morphology were examined in tension and shear tests. Fatigue fracture studies included an examination of the influence of minimum-to-maximum-load ratio on fracture morphology. Second-phase particles observed on fracture surfaces and metallographically prepared sections and corrosion products associated with stress corrosion fractures were analyzed chemically using scanning electron microscopy and energy-dispersive X-ray analysis. Fracture morphology was related to the microstructural features, the testing conditions, and the form of commercial product.

Bhandarkar, M. D.↗

Technology development for phosphoric acid fuel cell powerplant (phase 2)

The status of technology for the manufacturing and testing of 1200 sq. cm cell materials, components, and stacks for on-site integrated energy systems is assessed. Topics covered include: (1) preparation of thin layers of silicon carbide; (2) definition and control schemes for volume changes in phosphoric acid fuel cells; (3) preparation of low resin content graphite phenolic resin composites; (4) chemical corrosion of graphite-phenolic resin composites in hot phosphoric acid; (5) analysis of electrical resistance of composite materials for fuel cells; and (6) fuel cell performance and testing.

Christner, L.↗

Comparison of the Chromium Distribution in New Super Koropon Primer to 30 Year Old Super Koropon Using Focused Ion Beam/Scanning Electron Microscopy

Super Koropon primer (MB0125-055) plays a significant role in the corrosion protection of areas throughout the Orbiter. Because the Shuttle Program relies so heavily upon the performance of the Koropon primer, it is necessary to fully understand all aspects of the behavior of the coating. One area where little understanding of the Koropon primer still exists is the level of risk associated with age related degradation. Recently, efforts were undertaken to better understand the age life of the Koropon primer and to gain some insight into the aging process of this coating. In that study, an aluminum access panel from the Orbiter Enterprise was used to investigate the performance of the old Koropon film. A control panel was also used to study the performance of new Koropon coating. Preliminary investigations into the performance of aged Super Koropon primer indicated a significant decrease in corrosion protection. This investigation serves as an example of how Focused Ion Beam/Scanning Microscopy can be used to characterize the changes that occur as coatings age.

Lomness, Janice K.↗

Perspective—Localized Corrosion: Passive Film Breakdown vs Pit Growth Stability

A debate about the critical step in localized corrosion has raged for decades. Some researchers focus on the composition and structure of the passive film associated with the initial breakdown of the film, whereas others consider that the susceptibility to pitting is controlled by the pit growth kinetics and the stabilization of pit growth. The basis for a unified theory of pitting is presented here in which pit stability considerations are controlling under aggressive conditions (harsh electrolytes and extreme environments and/or susceptible microstructures) and the passive film properties and protectiveness are the critical factors in less extreme environments and/or for less susceptible alloys.

36 MATERIALS SCIENCE↗

Space Shuttle reaction control system thruster metal nitrate removal and characterization

The Space Shuttle hypergolic primary reaction control system (PRCS) thrusters continue to fail-leak or fail-off at a rate of approximately 1.5 per flight, attributed primarily to metal nitrate formation in the nitrogen tetroxide (N2O4) pilot operated valves (POV's). The failures have continued despite ground support equipment (GSE) and subsystem operational improvements. As a result, the Johnson Space Center (JSC) White Sands Test Facility (WSTF) performed a study to characterize the contamination in the N204 valves. This study prompted the development and implementation of a highly successful flushing technique using deionized (DI) water and gaseous nitrogen (GN2) to remove the contamination while minimizing Teflon seat damage. Following flushing a comprehensive acceptance test is performed before the thruster is deemed recovered. Between the time WSTF was certified to process flight thrusters (March 1992) and September 1993, a 68 percent thruster recovery rate was achieved. The contamination flushed from these thrusters was analyzed and has provided insight into the corrosion process, which is reported in this publication. Additionally, the long-term performance of 24 flushed thrusters installed in the WSTF Fleet Leader Shuttle reaction control subsystem (RCS) test articles is being assessed. WSTF continues to flush flight and test article thrusters and compile data to investigate metal nitrate formation characteristics in leaking and nonleaking valves.

Saulsberry, R. L.↗

Re-evaluation of Moisture Controls During ARIES Oxide Processing, Packaging and Characterization

DOE-STD-3013 [1] requires limiting the relative humidity (RH) in the glovebox during processing of the oxide product for specific types of plutonium oxides. This requirement is mandated in order to limit corrosion of the stainless steel containers by deliquescence of chloride salts if present in the PuO2. DOE-STD-3013 also specifies the need to limit and monitor internal pressure buildup in the 3013 containers due to the potential for the generation of free H2 and O2 gas from the radiolysis of surfaceadsorbed water. DOE-STD-3013 requires that the oxide sample taken for moisture content verification be representative of the stabilized material in the 3013 container. This is accomplished by either limiting the time between sampling and packaging, or by control of the glovebox relative humidity (%RH). This requirement ensures that the sample is not only representative, but also conservative from the standpoint of moisture content.

36 MATERIALS SCIENCE↗