Search NASA⌕ Search

SEARCH · Search NASA

Results for “Capacity estimation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Analytics Supporting Stockpile and Enterprise Planning [Slides]

A robust and growing modeling effort supports Los Alamos weapons leadership as well as NNSA (NA18, NA12, NA19) and DoD (DASD-NM, USSTRATCOM). Current work are valuable to several key NNSA working groups supporting strategic planning: Stockpile Stewardship Management Plan (SSMP); Requirements & Planning Document (RPD) analysis; Requirements and Capacity Working Group (RCWG); Production Integration Collaboration Working Group (PICWG); Enterprise Modeling and Analysis Consortium (EMAC); Cost Estimating Analysis Group (CEAG).

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Evaluation of selected chemical processes for production of low-cost silicon, phase 2

Potential designs for an integrated fluidized-bed reactor/zinc vaporizer/SiCl4 preheater unit are being considered and heat-transfer calculations have been initiated on versions of the zinc vaporizer section. Estimates of the cost of the silicon prepared in the experimental facility have been made for projected capacities of 25, 50, 75, and 100 metric ton of silicon. A 35 percent saving is obtained in going from 25 metric ton/year to the 50 metric ton/year level. This analysis, coupled with the recognition that use of two reactors in the 50 metric ton/year version allows for continued operation (at reduced capacity) with one reactor shut down, has resulted in a recommendation for adoption of an experimental facility capacity of 50 metric ton/year or greater. At this stage, the change to a larger size facility would not increase the design costs appreciably. In the experimental support program, the effects of seed bed particle size and depth were studied, and operation of the miniplant with a new zinc vaporizer was initiated, revealing the need for modification of the latter.

Blocher, J. M., Jr.↗

Evaluation of HCMM data for assessing soil moisture and water table depth

Soil moisture in the 0-cm to 4-cm layer could be estimated with 1-mm soil temperatures throughout the growing season of a rainfed barley crop in eastern South Dakota. Empirical equations were developed to reduce the effect of canopy cover when radiometrically estimating the soil temperature. Corrective equations were applied to an aircraft simulation of HCMM data for a diversity of crop types and land cover conditions to estimate the soil moisture. The average difference between observed and measured soil moisture was 1.6% of field capacity. Shallow alluvial aquifers were located with HCMM predawn data. After correcting the data for vegetation differences, equations were developed for predicting water table depths within the aquifer. A finite difference code simulating soil moisture and soil temperature shows that soils with different moisture profiles differed in soil temperatures in a well defined functional manner. A significant surface thermal anomaly was found to be associated with shallow water tables.

Moore, D. G.↗

Soil temperature investigations using satellite acquired thermal-infrared data in semi-arid regions

Thermal-infrared data from the Heat Capacity Mapping Mission satellite were used to map the spatial distribution of diurnal surface temperatures and to estimate mean annual soil temperatures (MAST) and annual surface temperature amplitudes (AMP) in semi-arid east central Utah. Diurnal data with minimal snow and cloud cover were selected for five dates throughout a yearly period and geometrically co-registered. Rubber-sheet stretching was aided by the WARP program which allowed preview of image transformations. Daytime maximum and nighttime minimum temperatures were averaged to generation average daily temperature (ADT) data set for each of the five dates. Five ADT values for each pixel were used to fit a sine curve describing the theoretical annual surface temperature response as defined by a solution of a one-dimensinal heat flow equation. Linearization of the equation produced estimates of MAST and AMP plus associated confidence statistics. MAST values were grouped into classes and displayed on a color video screen. Diurnal surface temperatures and MAST were primarily correlated with elevation.

Day, R. L.↗

The Development of Novel, High-Flux, Heat Transfer Cells for Thermal Control in Microgravity

In order to meet the future needs of thermal management and control in space applications such as the Space Lab, new heat-transfer technology capable of much larger heat fluxes must be developed. To this end, we describe complementary numerical and experimental investigations into the fundamental fluid mechanics and heat-transfer processes involved in a radically new, self contained, heat transfer cell for microgravity applications. In contrast to conventional heat pipes, the heat transfer in this cell is based on a forced droplet evaporation process using a fine spray. The spray is produced by a novel fluidic technology recently developed at Georgia Tech. This technology is based on a vibration induced droplet atomization process. In this technique, a liquid droplet is placed on a flexible membrane and is vibrated normal to itself. When the proper drop size is attained, the droplet resonates with the surface motion of the membrane and almost immediately bursts into a shower of very fine secondary droplets. The small droplets travel to the opposite end of the cell where they impact a heated surface and are evaporated. The vapor returns to the cold end of the cell and condenses to form the large droplets that are fragmented to form the spray. Preliminary estimates show that a heat transfer cell based on this technology would have a heat-flux capacity that is an order of magnitude higher than those of current heat pipes designs used in microgravity applications.

Smith, Marc K.↗

Mapping the Extent of Mangrove Ecosystem Degradation by Integrating an Ecological Conceptual Model with Satellite Data

Anthropogenic and natural disturbances can cause degradation of ecosystems, reducing their capacity to sustain biodiversity and provide ecosystem services. Understanding the extent of ecosystem degradation is critical for estimating risks to ecosystems, yet there are few existing methods to map degradation at the ecosystem scale and none using freely available satellite data for mangrove ecosystems. In this study, we developed a quantitative classification model of mangrove ecosystem degradation using freely available earth observation data. Crucially, a conceptual model of mangrove ecosystem degradation was established to identify suitable remote sensing variables that support the quantitative classification model, bridging the gap between satellite-derived variables and ecosystem degradation with explicit ecological links. We applied our degradation model to two case-studies, the mangroves of Rakhine State, Myanmar, which are severely threatened by anthropogenic disturbances, and Shark River within the Everglades National Park, USA, which is periodically disturbed by severe tropical storms. Our model suggested that 40% (597 km2) of the extent of mangroves in Rakhine showed evidence of degradation. In the Everglades, the model suggested that the extent of degraded mangrove forest increased from 5.1% to 97.4% following the Category 4 Hurricane Irma in 2017. Quantitative accuracy assessments indicated the model achieved overall accuracies of 77.6% and 79.1% for the Rakhine and the Everglades, respectively. We highlight that using an ecological conceptual model as the basis for building quantitative classification models to estimate the extent of ecosystem degradation ensures the ecological relevance of the classification models. Our developed method enables researchers to move beyond only mapping ecosystem distribution to condition and degradation as well. These results can help support ecosystem risk assessments, natural capital accounting, and restoration planning and provide quantitative estimates of ecosystem degradation for new global biodiversity targets.

Calvin K. F. Lee↗

Power quality of service optimization for microgrids

Various examples are provided for power quality of service optimization for microgrids. In one example, among others, a microgrid includes a smart meter configured to control supply of electric power to loads based at least in part upon energy consumption scheduling of the loads, which is based at least in part upon an effective electric generation capacity associated with the microgrid. The energy consumption scheduling can be based at least in part upon estimated power output of a sustainable energy resource of the microgrid and a load demand characterization of the loads. In another example, a system comprises a plurality of microgrids and an advanced metering infrastructure (AMI) configured to monitor operations of the microgrids and to control supply of electric power from sustainable energy resources and energy storage systems to loads of the microgrids via smart meters based at least in part upon energy consumption scheduling of the loads.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Analysis on the Influence of an Energy Storage System and Its Impact to the Grid for a Wave Energy Converter: Preprint

This paper presents an analysis on the cost of and how a battery storage system can be used to further reduce the variation of power generated from the wave energy converter (WEC) due to the fluctuating nature of waves and its impact to the grid. The electrical power output from WEC-Sim simulations for the six sea states used in the Wave Energy Prize was analyzed to compute the peak power and power time history. The results were used to evaluate the battery storage capacity that is needed for a WEC system to provide reasonable power flow to the grid and estimate its cost based on the latest cost information for battery technologies published by the U.S. Energy Information Administration. Finally, a preliminary grid integration analysis was performed to demonstrate how WEC-generated power would contribute to a small island electricity system. As shown in the study, the instantaneous peak power is the primary cost driver for the battery storage and the power take-off system, and reducing the power fluctuations is essential for reducing the overall levelized cost of energy (LCOE). The power flow variation from WECs can be significantly reduced using battery storage without adding significant overall system costs, and the implementation of battery storage is essential for grid integration applications. There may also be additional opportunities to further investigate energy storage technologies that are specific to WEC applications to reduce these costs even further.

16 TIDAL AND WAVE POWER↗

Experimental and Computational Study of Weld Drop-Through Hydraulic Effects in Multi-Layer Concentric Pipes Servicing Cryogenic Liquid Hydrogen

The Cryogenic Moderator System (CMS) at the Oak Ridge National Laboratory (ORNL)-Spallation Neutron Source (SNS) supplies liquid hydrogen, through vacuum insulated transfer lines to the moderators. The welding process used to make the transfer lines produces weld drop-through, which can constrict the flow of hydrogen and/or cause thermal bridges between adjacent layers. To ensure proper operation of the CMS it is therefore necessary to conduct a flow test to verify the pressure drop caused by the welds. Measurements in as-built piping sections intended to provide liquid hydrogen service to the SNS-CMS system were performed to test the effect of weld penetrations into the fluid flow area focusing on pressure drop effects. The reference test sections were designed using prototypical piping dimensions, materials and expected penetration welds. A numerical study using Computational Fluid Dynamics (CFD) tools in the transfer lines provided a conversion factor from the pressure drop measured in the lines with water to the expected pressure drop using liquid cryogenic hydrogen. The results show evidence of a maximum pressure drop modification in water of 78 KPa in the tested parts, which scales to liquid hydrogen as PHydrogen = 5.2 KPa. The maximum measured equivalent blockage area percentage was found in the as-built TDM transfer line spool 2 with a value of 31%. The measured values obtained in the as-built transfer lines provided accurate values to estimate the expected total pressure drop in the CMS system providing operational limits for the current recirculatory capacity. The effect of the weld drop-through in hydrogen evacuation capacity scenarios was better evaluated as a result of this study.

Dominguez-Ontiveros, Elvis [ORNL] (ORCID:000000018↗

Optimizing Air Transportation Service to Metroplex Airports: Analysis of Historical Data - Part 1

The air transportation system is a significant driver of the U.S. economy, providing safe, affordable, and rapid transportation. During the past three decades airspace and airport capacity has not grown in step with demand for air transportation (+4% annual growth), resulting in unreliable service and systemic delays. Estimates of the impact of delays and unreliable air transportation service on the economy range from $32B to $41B per year. This report describes the results of an analysis of airline strategic decision-making with regards to: (1) geographic access, (2) economic access, and (3) airline finances. This analysis evaluated markets-served, scheduled flights, aircraft size, airfares, and profit from 2005-2009. During this period, airlines experienced changes in costs of operation (due to fluctuations in hedged fuel prices), changes in travel demand (due to changes in the economy), and changes in infrastructure capacity (due to the capacity limits at EWR, JFK, and LGA). This analysis captures the impact of the implementation of capacity limits at airports, as well as the effect of increased costs of operation (i.e. hedged fuel prices). The increases in costs of operation serve as a proxy for increased costs per flight that might occur if auctions or congestion pricing are imposed.

Donohue, George↗

Dynamics of virtual water networks: Role of national socio-economic indicators across the world

Intensified water usage due to rapid industrialization is often dictated by economic policies based on monetary growth rather than sustainable use of environmental resources. In addition, interdependence within economic sectors further interweaves water usage through product transactions, which further makes it difficult to quantify the dynamics of hydro-economic systems at regional, national and global scale. In this study, we investigated the dynamics of domestic virtual water networks (VWN) of 189 countries based on concept of information theory by quantifying network metrics that describes VWN flow capacity, robustness, efficiency and flexibility. These networks represent virtual water interconnected through economic sectors within a specified country built based on environmentally extended multi region input output (EE-MRIO) approach. We further estimated trends associated with network metrics, as well as coupling intensity between metrics with respect to socio-economic indicators, such as, population, Gross Domestic Product (GDP) and Gross National Income (GNI). It was observed that capacity and flexibility of VWNs are strongly and positively correlated indicating that a high capacity VWN can be more flexible. Our results also indicate that, in general a higher percentage of developing countries (i.e. both least developing and developing nations) have exhibited increasing trends in capacity, robustness, efficiency and flexibility of VWN compared to developed nations. It was revealed that the dynamics of VWNs are positively coupled with socio-economic growth for few countries, which indicates the sustainable behavior of VWN with socio-economic growth. Our results argue that the information theory-based metrics by embedding water footprints can holistically capture sustainability aspect of the VWN dynamics.

54 ENVIRONMENTAL SCIENCES↗

Transportation and System Analysis Collaborations in Support of a Federal Consolidated Interim Storage Facility

The U.S. Department of Energy’s Integrated Waste Management (IWM) program under the Office of Nuclear Energy is planning for the future transportation, storage, and eventual disposal of spent nuclear fuel (SNF) and high-level radioactive waste (HLW) from nuclear power plant and waste custodian sites across the United States. To better enable informed decision-making regarding the back end of the nuclear fuel cycle, the IWM program has been sponsoring the development and application of system analysis tools capable of analyzing various options for managing SNF and HLW. With these tools, integrated waste management system (IWMS) architecture analyses are being conducted to support the future deployment of a comprehensive nuclear waste management system that considers all major back-end aspects of the nuclear fuel cycle (i.e., transportation, storage, and disposal). System analyses and assessments typically use these modeling and simulation tools to investigate implications of changes in various assumptions and parameters such as acceptance rates, receipt logic, facility capacities and capabilities, use of standardized canisters, start and stop dates of facilities, etc. The Next Generation System Analysis Model (NGSAM) is an agent-based simulation toolkit that is used for a system-level simulation and analysis focused on SNF management in the United States. NGSAM’s primary purpose is to provide a system analyst with capabilities to model the IWMS and gain insights into SNF and HLW management alternatives including the impact of system choices, associated cost estimates, and development of integrated yet flexible approaches. An analyst using NGSAM can define several factors like the number of storage facilities, capacity at each facility, transportation schedules, shipment rates, and other conditions. IWM is also developing the Stakeholder Tool for Assessing Radioactive Transportation (START). START is a web-based geospatial tool developed to provide the visualization and initial evaluation of transportation options associated with future SNF and HLW shipment planning and operations. This includes characterizing safety, economic, and environmental conditions at and in proximity to shipment origins as well as along prospective transportation routes. Information from the START tool can be presented/shared as maps, graphics, geospatial files, and tabular form to enable easy data representation and export functionality. The system analysis, NGSAM, and START teams have been working closely for several years before formalizing this collaboration. START provides the SNF transportation routing information for use in NGSAM. System analysts use the NGSAM tool to generate results (schedule, costs, infrastructure acquisitions, shipment rates, etc.). Subject-matter experts and system analysts work together to inform how NGSAM should model the waste management system. Specifically, this paper discusses the collaborations between the system analysis, NGSAM, and START teams and their accomplishments over the past year. Some examples of these efforts include calibrating and adding data to the START output files to meet NGSAM needs, gaining a better understanding of START data used in NGSAM as well as how updates in START data could result in an improved NGSAM analysis. Detailed examples of various tasks that have been performed by the team will be discussed in the full paper. Continued efforts in this direction are expected in the coming years.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Excess Heat Capacity in Mo/Au Transition Edge Sensor Bolometric Detectors

Excessheat capacity in a bolometric detector has the consequence of increasing or leading to multiple device time con-stants.The Mo/Au bilayer transition edge sensor (TES) bolo-metric detectors intended for the high resolution mid-infrared spectrometer (HIRMES) have two response time, one of which is a few times longer than that estimated from materials used in the design. The relative contribution of this settling time to the overall time response of the detectors is roughly proportional with the pixel area, which ranges between ~0.3 and 2.6 mm2.Use of laser ablation to remove sections of the silicon membranes comprising the pixels results in a detector response with a smaller contribution from the secondary time constant.Additional information about the nature of this excess heat capacity is gleaned from glancing in-cidence x-ray diffraction, which reveals the presence of molyb-denum silicides near the silicon surface from the bi-layer deposi-tion.Quantitative analysis of the concentration of excess molyb-denum, estimated with secondary ion mass spectroscopy, is com-mensurate to the additional heat capacity needed to explain the anomalous time response of the detectors.

HIRMES↗

Phase Transformation Contributions to Heat Capacity and Impact on Thermal Diffusivity, Thermal Conductivity, and Thermoelectric Performance

Abstract The accurate characterization of thermal conductivity κ, particularly at high temperature, is of paramount importance to many materials, thermoelectrics in particular. The ease and access of thermal diffusivity D measurements allows for the calculation of κ when the volumetric heat capacity, ρc p , of the material is known. However, in the relation κ = ρc p D , there is some confusion as to what value of c p should be used in materials undergoing phase transformations. Herein, it is demonstrated that the Dulong–Petit estimate of c p at high temperature is not appropriate for materials having phase transformations with kinetic timescales relevant to thermal transport. In these materials, there is an additional capacity to store heat in the material through the enthalpy of transformation Δ H . This can be described using a generalized model for the total heat capacity for a material where φ is an order parameter that describes how much latent heat responds “instantly” to temperature changes. Here, C pφ is the intrinsic heat capacity (e.g., approximately the Dulong–Petit heat capacity at high temperature). It is shown experimentally in Zn 4 Sb 3 that the decrease in D through the phase transition at 250 K is fully accounted for by the increase in c p , while κ changes smoothly through the phase transition. Consequently, reports of κ dropping near phase transitions in widely studied materials such as PbTe and SnSe have likely overlooked the effects of excess heat capacity and overestimated the thermoelectric efficiency, zT .

Agne, Matthias T.↗

Field Validation of Air-Source Heat Pumps for Cold Climates

Heating energy is the largest end-use for U.S. residential buildings accounting for approximately one-third of residential building energy consumption (EIA 2021). Historically, air-source heat pumps have been limited to temperate climates because of subpar performance at extremely cold outdoor air temperatures. However, recent advances to cold-climate air-source heat pump technology, which typically rely on inverter-driven, variable-speed compressors and variable-speed fans, have significantly improved low-temperature heat pump performance enabling the technology to save energy for many homes in cold climates. The primary objective of this project was to measure in-field performance of centrally ducted, variable-capacity air-source heat pumps in cold climates to validate performance and develop field-based performance maps. The project focused on quantifying heat pump performance at cold temperatures. The sites identified for the study were primarily located in the Northwest United States since homes in the region tend to have all-electric space heating systems and high-efficiency heat pumps have been incentivized in the region for several years. NREL partnered with Ecotope, Inc., a small energy consulting firm located in Seattle, WA, for site recruitment, monitoring equipment installation, data quality management. All the sites included in the study had previously installed a high-efficiency, central heat pump system. One site was in a Denver, CO suburb, which was the only dual fuel heat pump in the study. We used airside and power measurements, collected at 5-second intervals, to quantify heat pump capacity, coefficient of performance (COP), and auxiliary heater energy consumption. We developed algorithms to automatically determine the heat pump operating mode including defrost and auxiliary heating operation. A whole-house thermal and duct audit was completed during the initial site visit to estimate winter heating loads and assess heat pump sizing. Whole-home heating design loads were calculated at ASHRAE 99% design temperatures and compared to manufacturer-reported maximum capacities to assess the heat pump sizing at each site.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Sensitivity analysis for best-estimate thermal models of vertical dry cask storage systems

Loading requirements for dry cask storage of spent nuclear fuel are driven primarily by decay heat capacity limitations, which themselves are determined through recommended limits on peak cladding temperature within the cask. This study examines the relative sensitivity of peak material temperatures within the cask to parameters that influence both the stored fuel residual decay heat as well as heat removal mechanisms. Here, these parameters include the detailed reactor operating history parameters (e.g., soluble boron concentrations and the presence of burnable poisons) as well as factors that influence heat removal, including non-dominant processes (such as conduction from the fuel basket to the canister and radiation within the canister) and ambient environmental conditions. By examining the factors that drive heat removal from the cask alongside well-understood factors that drive decay heat, it is therefore possible to make a contextual analysis of the most important parameters to evaluation of peak material temperatures within the cask.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A Proposed Path Forward for Standardization - 17131

Incorporation of a standardized canister system into the commercial waste management system represents an opportunity to develop an integrated approach to storage, transportation, and disposal issues. However, regardless of timing and method, deployment of such a system would have the potential to cause significant system-wide impacts. The current inventory of commercial spent nuclear fuel dry storage systems is diverse and increasing. In addition, the currently loaded systems are large-capacity systems (up to 37 pressurized water reactor assemblies or 89 boiling water reactor assemblies) that are now able to accommodate large (greater than 45 kilowatts) amounts of heat during storage, with the potential to accommodate fairly high heat loads (∼32 kilowatts) for transportation as well. A standardized canister system designed with disposition in mind would likely be significantly smaller than the current systems and have dramatically lower heat limit maximums. Over the past few years, the Department of Energy (DOE) Office of Nuclear Energy Fuel Cycle Technologies Nuclear Fuels Storage and Transportation Planning Project (NFST) has performed a number of system analyses using logistic simulations to evaluate the impacts of incorporating these smaller canisters into the commercial waste management system. These simulations predict the amount of resources (e.g., staff, canisters/casks, rail-cars, facilities), the size of facilities, and the timing of operations, as well as provide rough order-of-magnitude cost estimates. In addition to system analyses, DOE funded efforts by EnergySolutions to develop a generic design of a small-capacity standardized canister system and investigate innovative operational approaches to minimize the at-reactor operational impacts of loading such smaller canisters. A result of EnergySolutions' work was the development of a 'canister-in-carrier' concept that would allow for loading, storing, transporting, and potentially disposing of groups of small canisters at the same time. With the inclusion of this new concept, the most recent system analyses show that incorporating standardized canister systems into the commercial waste management system has the potential for some system-wide cost reductions in addition to the flexibility that smaller canisters would provide to the system. Based on these analyses, the authors of this paper recommend that DOE fund (1) a demonstration of the ability to weld up to four small canisters at the same time to confirm the feasibility and practicality of the canister-in-carrier concept and (2) the development of a more detailed conceptual design for future applications for Certificates of Compliance, if standardized canisters were incorporated into the commercial waste management system. This paper documents both the results of the latest assessment of standardized canister concepts including the canister-in-carrier concept and the authors' recommendations. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Fast simulation of packet loss rates in a shared buffer communications switch

This paper describes an efficient technique for estimating, via simulation, the probability of buffer overflows in a queueing model that arises in the analysis of ATM (Asynchronous Transfer Mode) communication switches. There are multiple streams of (autocorrelated) traffic feeding the switch that has a buffer of finite capacity. Each stream is designated as either being of high or low priority. When the queue length reaches a certain threshold, only high priority packets are admitted to the switch's buffer. The problem is to estimate the loss rate of high priority packets. An asymptotically optimal importance sampling approach is developed for this rare event simulation problem. In this approach, the importance sampling is done in two distinct phases. In the first phase, an importance sampling change of measure is used to bring the queue length up to the threshold at which low priority packets get rejected. In the second phase, a different importance sampling change of measure is used to move the queue length from the threshold to the buffer capacity.

Chang, Cheng-Shang↗