Search NASA⌕ Search

SEARCH · Search NASA

Results for “Cooling system efficiency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Heat Based Power Augmentation for Modular Pumped Hydro Storage in Smart Buildings Operation

In the U.S., building sector is responsible for around 40% of total energy consumption and contributes about 40% of carbon emissions since 2012. Within the past several years, various optimization models and control strategies have been studied to improve buildings energy efficiency and reduce operational expenses under the constraints of satisfying occupants’ comfort requirements. However, the majority of these studies consider building electricity demand and thermal load being satisfied by unidirectional electricity flow from the power grid or on-site renewable energy generation to electrical and thermal home appliances. Opportunities for leveraging low grade heat for electricity have largely been overlooked due to impracticality at small scale. In 2016, a modular pumped hydro storage technology was invented in Oak Ridge National Laboratory, named Ground Level Integrated Diverse Energy Storage (GLIDES). In GLIDES, employing high efficiency hydraulic machinery instead of gas compressor/turbine, liquid is pumped to compress gas inside high-pressure vessel creating head on ground-level. This unique design eliminates the geographical limitation associated with existing state of the art energy storage technologies. It is easy to be scaled for building level, community level and grid level applications. Using this novel hydro-pneumatic storage technology, opportunities for leveraging low-grade heat in building can be economical. In this research, the potential of utilizing low-grade thermal energy to augment electricity generation of GLIDES is investigated. Since GLIDES relies on gas expansion in the discharge process and the gas temperature drops during this non-isothermal process, available thermal energy, e.g. from thermal storage, Combined Cooling, Heat and Power system (CCHP), can be utilized by GLIDES to counter the cooling effect of the expansion process and elevate the gas temperature and pressure and boost the roundtrip efficiency. Several groups of comparison experiments have been conducted and the experimental results show that a maximum 12.9% cost saving could be achieved with unlimited heat source for GLIDES, and a moderate 3.8% cost improvement can be expected when operated coordinately with CCHP and thermal energy storage in a smart building.

Chen, Yang↗

Coupled Heat Power Operation of Smart Buildings via Modular Pumped Hydro Storage

In the United States, building sector is responsible for around 40% of total energy consumption and contributes about 40% of carbon emissions since 2012. Within the past several years, various optimization models and control strategies have been studied to improve buildings’ energy efficiency and reduce operational expenses under the constraints of satisfying occupants’ comfort requirements. However, the majority of these studies consider building electricity demand and thermal load being satisfied by unidirectional electricity flow from the power grid or on-site renewable energy generation to electrical and thermal home appliances. Opportunities for leveraging low-grade heat for electricity have largely been overlooked due to impracticality at small scale. In 2016, a modular pumped hydro storage technology was invented in Oak Ridge National Laboratory, named Ground Level Integrated Diverse Energy Storage (GLIDES). In GLIDES, employing high-efficiency hydraulic machinery instead of gas compressor/turbine, liquid is pumped to compress gas inside high-pressure vessel creating head on ground level. This unique design eliminates the geographical limitation associated with the existing state-of-the-art energy storage technologies. It is easy to be scaled for building level, community level, and grid level applications. By using this novel hydro-pneumatic storage technology, opportunities for leveraging low-grade heat in building can be economical. In this research, the potential of utilizing low-grade thermal energy to augment electricity generation of GLIDES is investigated. Since GLIDES relies on gas expansion in the discharge process and the gas temperature drops during this non-isothermal process, available thermal energy, e.g., from thermal storage, combined cooling, heat and power system (CCHP), can be utilized by GLIDES to counter the cooling effect of the expansion process and elevate the gas temperature and pressure and boost the roundtrip efficiency. Here, several groups of comparison experiments have been conducted, and the experimental results show that a maximum 12.9% cost saving could be achieved with unlimited heat source for GLIDES, and a moderate 3.8% cost improvement can be expected when operated coordinately with CCHP and thermal energy storage in a smart building.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Transpiration Cooling Experiment

The transpiration cooling method was considered for a scram-jet engine to accommodate thermally the situation where a very high heat flux (200 Btu/sq. ft sec) from hydrogen fuel combustion process is imposed to the engine walls. In a scram-jet engine, a small portion of hydrogen fuel passes through the porous walls of the engine combustor to cool the engine walls and at the same time the rest passes along combustion chamber walls and is preheated. Such a regenerative system promises simultaneously cooling of engine combustor and preheating the cryogenic fuel. In the experiment, an optical heating method was used to provide a heat flux of 200 Btu/sq. ft sec to the cylindrical surface of a porous stainless steel specimen which carried helium gas. The cooling efficiencies by transpiration were studied for specimens with various porosity. The experiments of various test specimens under high heat flux have revealed a phenomenon that chokes the medium flow when passing through a porous structure. This research includes the analysis of the system and a scaling conversion study that interprets the results from helium into the case when hydrogen medium is used.

Song, Kyo D.↗

Integrating diagnostics and model-based optimization

Energy Management and Information Systems are a family of analytics technologies that include energy information systems, fault detection and diagnostics (FDD), and automated system optimization tools. Such systems have the potential to enable buildings to meet energy management goals of reducing total energy consumption and cost. Most current market offerings use data-driven and rule-based analytics. However, the use of physics-based models in the analytics offers potential improvements by providing an accurate estimation of outputs based on representation of the physical principles governing the building system behaviors. This also permits the use of design stage models to inform commissioning and operation. This paper describes the development and testing of a hybrid data-driven and physics model-based operational tool for energy efficiency in central cooling plants. The tool offers FDD functionality, setpoint optimization, and visualization of key performance parameters. It was demonstrated at a university campus in the mixed-humid ASHRAE Climate Zone 4A. Key performance metrics that were analyzed include plant electricity use reduction, plant model calibration, and system economics. Annual simulations indicate the tool can provide electricity savings of greater than 10% for approximately six months of the year, mainly during the winter season when wet bulb temperatures are low, though only 1.38% savings for the entire year. Additionally, over a 4-day period in April, recommended optimal setpoints were implemented, resulting in 17% savings versus metered baseline consumption. With respect to model calibration, the difference between model-predicted and measured parameters was less than 10% for 90% of data points acquired for three of six chillers, and for each ten cooling towers. Finally, the tool users reported that satisfaction with the capabilities was equal to or better than that with the preexisting BAS system.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Collisional simulations of the modulator section in coherent electron cooling

The first section of any coherent electron cooling (CeC) system is the modulator, where the density of the electron beam is modulated by the copropagating ion beam. This density modulation is a result of Coulomb collisions between the individual particles of the two beams. The pairwise, stochastic part of the interactions impacts the overall performance of the CeC process. We present the first simulations of the density modulations of the electron beams from a collisional picture of the dynamics, considering the proof-of-principle CeC experiments at Brookhaven National Laboratory. These simulations were performed using PHAD, which is the first efficient, large-scale collisional numerical method in beam physics that we have previously developed and benchmarked. Realistic beam distributions and external fields have been optimized to provide strong modulation signals necessary for variations of coherent electron cooling systems. Cooling performance limits and potential collisionless simulation pitfalls are pointed out. Published by the American Physical Society 2024

43 PARTICLE ACCELERATORS↗

Degradation of Poly- and Perfluoroalkyl Substances (PFAS) in Water via High Power, Energy-Efficient Electron Beam Accelerator

The goal of the 2-year workplan was to see if electron beam (EB) could be used to break down a sub-set of the larger chemical family of per and polyfluoroalkylated substances (PFAS) in an energy efficient and economical manner when compared to conventional water treatment technologies. Year one (Y1) work focused on sample EB treatment work in the Fermi National Accelerator Laboratory’s (FNALs) Accelerator Applications Demonstration and Development (A2D2) EB accelerator. While there are reportedly thousands of types of PFAS, for the point of most of the work herein, a small subset was examined, typically perfluorooctane sulfonate (PFOS) and perfluorooctanoate (PFOA). PFOA and PFOS are two of the most well studied PFAS and are studied for baseline evaluations and are considered most useful. The work from Y1 provided information about the optimal operating parameters and additives to use when treating PFOS and PFOA via EB. The data were then used to see where in a water treatment system an EB accelerator would be best suited to treat PFAS. A conventional water treatment technology, GAC, was then compared to e-beam treatment technology with respect to energy and costs for treatment. In year two (Y2), several conventional e-beam accelerator designs, and FNAL’s developmental compact SRF accelerator design, were evaluated for their suitability in PFAS treatment, from an energy efficiency and cost standpoint. Several EB parameters were evaluated and optimized for the removal of PFOA and PFOS from water at normal pressure and temperature, measured as total PFAS removal. Under the optimized test conditions both PFOA showed complete destruction to inorganic fluoride, and PFOS to inorganic fluoride and sulfate, with mass balance. The effect on PFAS removal relative to solution pH, total EB dose, EB dose rate, dissolved oxygen concentration (DO), temperature, and initial PFAS concentration were evaluated. In general, PFOA was easier to destroy than PFOS. Degradation products, typically observed under less-than-optimal EB conditions, provided insight to degradation mechanisms. Products were identified to rule out possible deleterious biproduct formation. The water radiolysis radical reaction kinetics with PFOS and PFOA were not dependent on the initial concentration over 5-orders of magnitude from 2 μg/L to 20 mg/L. This is thought to be because there was an overabundance of the reactive water radiolysis radicals relative to PFAS molecules and largely attributed to aqueous electrons. The reaction rates appeared to be diffusion limited. Testing at higher concentrations (100-200 mg/L) showed a decrease in removal efficiency, suggesting alternative kinetics, possibly second order rates, at higher concentrations. In all, we successfully defined a set of optimal EB parameters to treat PFOA and PFOS at concentrations of 20 mg/L in water with destruction efficiencies near 100%. We further tested the optimized EB parameters with other types of PFAS, including shorter and longer fluorocarbon chain homologs of PFOA and PFOS, and PFAS with alternative functional groups such as sulfonamides. Based on our results EB can be optimized as an effective destructive technology for removing PFAS from water. The conditions optimized for PFOA and PFOS were less effective with ultra-short fluorocarbon compounds like TFMS, PFES, PFPS and PFBS, and likely require re-optimization of parameters to them. In all, it was determined that from a cost and energy efficiency standpoint, EB would be best applied to waste streams with relatively high concentrations of PFOS and PFOA and is not as cost effective as GAC treatment for removing low concentrations of PFAS from water. Higher concentrations of PFAS can be found in the wastewater of conventional treatment processes such as RO and IE and therefore EB may be used to supplement such treatment technologies. Some real-world IE regeneration wash water and RO reject water containing higher concentrations of PFAS and obtained from pilot scale industrial wastewater treatment system at a fluorochemical manufacturing facility, showed that EB could remove PFAS from such types of wastewaters. The IE regenerant wash water appeared to be the most efficient of the two types of wastewaters tested. However, some further optimization of the EB parameters for the specific PFAS types present in those wastewaters may be required. Also, the effects of co-present TOC and mineral salts should be considered during such optimization efforts. From the experimental Y1 results it was seen that the aqueous electron drives degradation of the PFAS. In a hypothetical water treatment skid using EB for PFAS destruction the parameters of the system should be optimized to promote aqueous electron production. Before EB treatment, the PFAS should be preconcentrated when possible, the pH should be raised to pH 10 or higher to enhance aqueous electron production, and the water should be nitrogen purged to remove dissolved oxygen to minimize aqueous electron scavenging. An excel spreadsheet was created that calculates optimal conditions based on inlet PFAS concentration and desired outlet concentration, by optimizing the accelerator power, dose rate, water treatment rate, pH and dissolved oxygen levels to reach the desired endpoint. Given this information on accelerator operating conditions five different EB accelerator systems were compared. One EB system was a continuous-wave, linear superconducting accelerator being designed at Fermilab. Three other EB systems (IMPELA at 5% and 25% duty factor and the ILU-14) were normal conducting pulsed linear accelerators. The fifth system was an IBA Rhodotron which is a normal conducting, circular, continuous-wave accelerator. The accelerator efficiency (% of the incoming power that is used in water treatment) was the dominating factor in accelerator choice. The radio frequency (RF) power supply and the accelerator design (superconducting versus warm technology) drive the accelerator efficiency. The IBA Rhodotron was seen to be the most energy efficient commercially available technology with a wall-plug (total) power efficiency of 43% at 400 kW. The Fermilab design, with a prototype for a different application currently being fabricated, was the most energy efficient at 55% when driven by a Klystron RF power supply and as high as 77% when powered by a magnetron. As the Fermilab design was the most energy efficient by approximately 10-30%, further design work was done on the accelerator and beam delivery system specific to the destruction of PFAS in water. The Fermilab design is unique from industrial accelerators in that is superconducting. Superconducting technology allows for the acceleration of electrons without losses. The accelerator must be cooled to below the point where it is superconducting and is operated around 4 degrees Kelvin. The bulk of the design work for the accelerator is on making the accelerator as energy efficient as possible so that it does not require liquid helium and can be cooled with conduction cooling via cryocoolers. Final design work resulted in an EB accelerator that would operate at minimally 200 kW and 10 MeV. Prototype construction would cost $\$ $7.8 million dollars when driven by a Klystron power supply. A second version of the same accelerator would cost $\$ $5.5 million dollars when driven by a magnetron that is still under development. The commercially available 300 kW IBA Rhodotron cost was estimated at approximately $\$ $9 million. While it is hard to directly compare, an operational GAC system used by 3M for groundwater treatment capital cost (2022 dollars) was estimated to cost $\$ $3.3 million. While the capital expense of the EB accelerator systems was higher than GAC, the accelerator EB treatment would result in destruction of the PFAS and not just sequestration of PFAS to form a new waste stream that requires further treatment or disposal. The operating cost to destroy the PFAS via 400 kw EB system was less than $\$ $1000/kg of PFAS destroyed when treating at a 20 mg/L PFAS concentration, compared to GAC with operating costs that calculated at $\$ $27,530 per kg of PFAS sequestered when treating 100 μg/L PFOA and PFOS combined concentration.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Feasibility and Utility of a Cryogenic Integrated RCS

Traditional in-space propulsion systems use storable propellants, such as MMH/NTO, for applications beyond Low Earth Orbit (LEO). Modern advancements in Cryogenic Fluid Management (CFM) technologies opens the door for use of more efficient cryogenic propellants, such as LOX/LCH4 or LOX/LH2, in these long-duration missions beyond LEO. As these Main Propulsion Systems (MPS) transition to cryogenic propellants, a cryogenic solution for Reaction Control Systems (RCS) becomes attractive for several reasons. A mixed-fluid vehicle solution with cryogenic (cool) MPS and storable (warm) RCS complicates thermal management. Additionally, a vehicle with common cryogenic propellant across the MPS and RCS could take advantage of shared hardware such as tanks, thermal management equipment, and pressurization system, reducing mass and development time. The fluid system design proposed in this presentation features shared hardware, leading to the designation of Cryogenic Integrated Reaction Control System (iRCS). The iRCS design stores cryogenic propellant in the low-pressure (10’s psia) MPS tanks, creates steady high-pressure (100’s psia) flow through an electric pump (e-pump), feeds pulse-firing RCS thrusters, and returns any excess flow to the tank through a pressure control device on a recirculation line. This iRCS design is inspired by the automotive fuel-rail, where similar elevated-pressure and pulse-firing requirements are levied. This design has several inherent advantages. Because this design is pump-fed rather than pressure-fed, heavy, high-pressure propellant storage is not required. The RCS propellant can therefore be stored by increasing MPS tank volume. Furthermore, by increasing the pressure of the circulated fluid through an e-pump, the propellant quality moves further into the sub-cooled regime. Sub-cooled liquid is desirable for accurate pressure and flow control at the thruster inlet. Lastly, the iRCS allows the distribution system hardware to maintain cryogenic temperatures by slowly recirculating liquid in a low-energy “Idle Mode”. Altogether, the iRCS concept enables a more efficient cryogenic vehicle design.

Integrated Reaction Control System↗

Feasibility and Utility of a Cryogenic Integrated RCS

Traditional in-space propulsion systems use storable propellants, such as MMH/NTO, for applications beyond Low Earth Orbit (LEO). Modern advancements in Cryogenic Fluid Management (CFM) technologies opens the door for use of more efficient cryogenic propellants, such as LOX/LCH4 or LOX/LH2, in these long-duration missions beyond LEO. As these Main Propulsion Systems (MPS) transition to cryogenic propellants, a cryogenic solution for Reaction Control Systems (RCS) becomes attractive for several reasons. A mixed-fluid vehicle solution with cryogenic (cool) MPS and storable (warm) RCS complicates thermal management. Additionally, a vehicle with common cryogenic propellant across the MPS and RCS could take advantage of shared hardware such as tanks, thermal management equipment, and pressurization system, reducing mass and development time. The fluid system design proposed in this presentation features shared hardware, leading to the designation of Cryogenic Integrated Reaction Control System (iRCS). The iRCS design stores cryogenic propellant in the low-pressure (10’s psia) MPS tanks, creates steady high-pressure (100’s psia) flow through an electric pump (e-pump), feeds pulse-firing RCS thrusters, and returns any excess flow to the tank through a pressure control device on a recirculation line. This iRCS design is inspired by the automotive fuel-rail, where similar elevated-pressure and pulse-firing requirements are levied. This design has several inherent advantages. Because this design is pump-fed rather than pressure-fed, heavy, high-pressure propellant storage is not required. The RCS propellant can therefore be stored by increasing MPS tank volume. Furthermore, by increasing the pressure of the circulated fluid through an e-pump, the propellant quality moves further into the sub-cooled regime. Sub-cooled liquid is desirable for accurate pressure and flow control at the thruster inlet. Lastly, the iRCS allows the distribution system hardware to maintain cryogenic temperatures by slowly recirculating liquid in a low-energy “Idle Mode”. Altogether, the iRCS concept enables a more efficient cryogenic vehicle design.

Integrated↗

A MHD channel study for the ETF conceptual design

The procedures and computations used to identify an MHD channel for a 540 mW(I) EFT-scale plant are presented. Under the assumed constraints of maximum E(x), E(y), J(y) and Beta; results show the best plant performance is obtained for active length, L is approximately 12 M, whereas in the initial ETF studies, L is approximately 16 M. As MHD channel length is reduced from 16 M, the channel enthalpy extraction falls off, slowly. This tends to reduce the MHD power output; however, the shorter channels result in lower heat losses to the MHD channel cooling water which allows for the incorporation of more low pressure boiler feedwater heaters into the system and an increase in steam plant efficiency. The net result of these changes is a net increase in the over all MHD/steam plant efficiency. In addition to the sensitivity of various channel parameters, the trade-offs between the level of oxygen enrichment and the electrical stress on the channel are also discussed.

Wang, S. Y.↗

Thermal and Environmental Barrier Coatings for Advanced Turbine Engine Applications

Ceramic thermal and environmental barrier coatings (T/EBCs) will play a crucial role in advanced gas turbine engine systems because of their ability to significantly increase engine operating temperatures and reduce cooling requirements, thus help achieve engine low emission and high efficiency goals. Advanced T/EBCs are being developed for the low emission SiC/SiC ceramic matrix composite (CMC) combustor applications by extending the CMC liner and vane temperature capability to 1650 C (3000 F) in oxidizing and water vapor containing combustion environments. Low conductivity thermal barrier coatings (TBCs) are also being developed for metallic turbine airfoil and combustor applications, providing the component temperature capability up to 1650 C (3000 F). In this paper, ceramic coating development considerations and requirements for both the ceramic and metallic components will be described for engine high temperature and high-heat-flux applications. The underlying coating failure mechanisms and life prediction approaches will be discussed based on the simulated engine tests and fracture mechanics modeling results.

Zhu, Dong-Ming↗

Electric Aircraft Thermal Management Using a Two-Phase Heat Transport System with Solid-State Thermal Switching Capability

Advanced Cooling Technologies, Inc. (ACT) is collaborating with NASA Glenn Research Center (GRC) to develop a heat pipe-based thermal delivery system to efficiently manage the waste heat generated onboard an electric aircraft. The heat pipe system will interface with NASA GRC’s thermoacoustic heat pump in order to recycle waste heat by transporting thermal energy to various end users onboard the aircraft. This paper discusses the layout of theoretical heat pipe networks for a MW-class commercial electric aircraft. This is followed by a discussion of progress made on the development of a novel two-phase heat transport system with solid-state thermal switching and control capabilities.

Exergy↗

Connected Thermostat Alternatives for Room Air Conditioners and Minisplit Heat Pumps

The availability of smart, connected thermostats has improved climate control, energy efficiency, and grid demand-response programs for central HVAC systems. However, a significant gap exists in addressing integrated control systems for point-source heating and cooling systems such as window air-conditioners (window ACs) and mini-split heat pumps (MSHPs). This report examines the emerging market of third-party connected thermostats tailored for these systems, focusing on their effectiveness, reliability, and potential barriers to adoption.This study evaluates several commercially available products designed for room ACs and MSHPs through a series of laboratory tests. While these infrared-based (IR-based) thermostats offer remote temperature control and scheduling via mobile apps, our findings reveal that none are seamless, with reliability of basic functions being a critical factor. Promising features include integration of indoor air quality metrics and time-of-use pricing, but the latter are not yet available in the U.S. Barriers to broad user acceptance include non-seamless setup processes, challenges in thermostat placement, and unclear product differentiation. There is a pressing need for research and development in enabling MSHPs and central thermostats to coordinate, enhancing energy savings and comfort in retrofit applications. This study underscores the importance of further innovation in connected thermostat technology to address the diverse needs of single-zone HVAC systems and promote efficient energy management in households.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

NASA Utilization of Space Nuclear Systems for Robotic and Human Exploration Missions: Response to EO 13972: Promoting Small Nuclear Reactors for National Defense and Space Exploration

Space Nuclear Systems (SNS) technology development offers a wide range of capabilities to support NASA’s current and future missions. Executive Order (EO) 13972, “Promoting Small Modular Reactors for National Defense and Space Exploration” [1], issued 5 January 2021, directs NASA to define requirements for NASA utilization of nuclear energy systems for human and robotic exploration missions through 2040 and analyze the costs and benefits of such requirements.” Although it is premature to define requirements and cost for future exploration missions that have not yet been formulated, this report describes planned objectives and missions by 2040 that are enabled or enhanced by nuclear systems while taking into account a number of unique considerations for nuclear energy in the space environment. Nuclear energy systems are enabling for space missions and critical capabilities where conventional forms of energy production are impractical or impossible due to mass constraints, mission duration, or distance from the Sun. Space nuclear technologies available or in development for use by 2040 utilize radioisotope decay or nuclear fission and fall into three categories: heat, power, and propulsion. Current applications utilize radioisotope power systems that provide consistent and reliable performance in the sub-kilowatt power range. More advanced SNS can enable new mission objectives where high energy density solutions are critical, or where access to solar solutions is prohibitive. Higher power radioisotope and fission systems are under development within NASA for a wide variety of human exploration and science mission applications. Planned missions designed to use radioisotope systems include Dragonfly, a rotorcraft that will explore the surface of Titan, and Persephone, a mission concept for a Pluto orbiter. Nuclear fission systems have the key advantage of providing significantly higher power, lower mass solutions from tens to even thousands of kilowatts. Fission power is enabling to a sustained human presence on the Moon and developing a robust lunar economy. Fission propulsion is enabling for missions within and beyond cis-lunar space. This report examines NASA-envisioned mission applications and associated performance needs for SNS over the next twenty years leading to 2040 along with the unique technical considerations posed by space nuclear technology development. This includes engineering and operational logistics for ground handling, thermal management, survival of the space environment, operational safety, power requirements, and service longevity. Safety to the public, the NASA work force, and agency assets remains a top priority for NASA and particular attention is given to this aspect in the design, hardware assembly, ground operation, launch, and mission operation of an SNS. NASA relies on the Department of Energy as nuclear authority and its legacy of rigorous safety procedures as standards for ground development, test, transportation, and launch site operation. The principal concern is preventing unintended radiological release to the public or environment. Radioisotope system experience has established processes, including ground operation, transportation, and launch, that are considered directly applicable to emerging fission systems; however, fission systems have unique design needs that impact the safety and performance requirements. High efficiency power conversion from both fission and radioisotope systems requires high operating temperatures necessitating both passive and active thermal management to maintain safe and nominal operating conditions. Effective cooling and waste heat rejection have special considerations for space applications, whether in zero-g or reduced gravity. Fluid and heat transfer within the reactor system is not anticipated to be impacted by reduced or zero-g environments. Cryogenic working fluids and propellant supplies utilized in some space nuclear applications will need low mass, high capacity cryocoolers to meet the long-term storage and near zero-boiloff needs. Integrated, high power density SNS capable of being packaged in a single vehicle is a key consideration for NASA. Due to concerns for complexity and reliability, in space reactor assembly and reactor refueling are not current design considerations. Expanding into a new era for space exploration depends on mass-efficient, high-energy solutions to power deep-space vehicles, operate in harsh environments, and increase mission flexibility. NASA nuclear technology investments are targeting power for surface operations and propulsion for fast-transit, deep-space missions, all with the ability to reliably operate without the need for repair or refueling. NASA’s goals, enabled by nuclear technologies, provide for exciting advances in scientific objectives and human exploration, ushering in a new space age that enables a human presence on bodies beyond our Earth.

nuclear↗

Microstructure Evolution and Durability of Advanced Environmental Barrier Coating Systems for SiC/SiC Ceramic Matrix Composites

Environmental barrier coated SiC-SiC ceramic matrix composites (CMCs) systems will play a crucial role in next generation turbine engines for hot-section component applications because of their ability to significantly increase engine operating temperatures with improved efficiency, reduce engine weight and cooling requirements. Advanced HfO2 and rare earth silicate environmental barrier coatings (EBCs), along with multicomponent hafnium and rare earth silicide EBC bond coats have been developed. The coating degradation mechanisms in the laboratory simulated engine thermal cycling, and fatigue-creep operating environments are also being investigated. This paper will focus on the microstructural and compositional evolutions of an advanced environmental barrier coating system on a SiC-SiC CMC substrate during the high temperature simulated durability tests, by using a Field Emission Gun Scanning Electron Microscopy, Energy Dispersive Spectroscopy (EDS) and Wavelength Dispersive Spectroscopy (WDS). The effects of Calcium-Magnesium-Alumino-Silicate (CMAS) from road sand or volcano-ash deposits on the degradation mechanisms of the environmental barrier coating systems will also be discussed. The detailed analysis results help understand the EBC-CMC system performance, aiming at the durability improvements to achieve more robust, prime-reliant environmental barrier coatings.

ceramic matrix composites↗

Evaluating Performance, Power, and Cooling in High Performance Computing (HPC) Data Centers

This chapter explores current research focused on developing our understanding of the interrelationships involved with HPC performance and energy management. The first section explores data center instrumentation, measurement, and performance analysis techniques, followed by a section focusing on work in data center thermal management and resource allocation. This is followed by an exploration of emerging techniques to identify application behavioral attributes that can provide clues and advice to HPC resource and energy management systems for the purpose of balancing HPC performance and energy efficiency.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Improving Data Center Energy Efficiency Through End-to-End Cooling Modeling and Optimization. Final Report

This report summarizes the development and demonstration of the three features developed for the DOE project “Improving Data Center Energy Efficiency through End-to-End Cooling Modeling and Optimization” (Award No. DE-EE0007688). The development of the three software features, Feature 1: Optimization of Cooling System Operation, Feature 2: Optimization of Airflow Management System, and Feature 3: Simultaneous Optimization of Airflow Management and Cooling Systems, are described first. Feature 1 is implemented in Phase 1 of the project and demonstrates 15% energy savings from cooling system optimization by applying the proposed retrofit solutions. Feature 2 is implemented in Phase 2 and the assessments show cooling energy-saving potential between 19.3% and 54.0%, depending on the energy-saving measures employed. In addition, investigating the energy saving potential for a hypothetical simple data center shows about 6.8% energy savings by optimizing the server load placement. Feature 3 is implemented in Phase 3 and the results show energy savings of 53.4% and 74.6% for the two partner data centers, respectively, compared to the baselines defined in Phase 1. Lastly, the project outcomes including software releases and publications are discussed.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Reducing Data Center Peak Cooling Demand and Energy Costs with Underground Thermal Energy Storage (UTES)

By recent estimates, data center energy demands are projected to consume between 6.7% and 12% of U.S. annual electricity generation by the year 2028, driven primarily by expanded demands from cloud services, big data analytics, and Artificial Intelligence (AI) (Shehabi et al., 2024). As much as 40% of data center total energy consumption are loads associated with the site infrastructure cooling systems, and these are often highly water consumptive (Aljbour et al., 2024). For energy system planners, this presents significant challenges to meeting and managing the anticipated loads, and especially the peak loads of projected data center deployments. Geothermal technologies offer two unique solutions to these challenges: 1) by serving loads through the deployment of new conventional and/or next-generation geothermal power technologies such as EGS and 2) through an often-overlooked opportunity to reduce data center peak cooling loads. The latter is the focus of this paper which explores Cold Underground Thermal Energy Storage ("Cold UTES") as an emerging industrial-scale geothermal cooling solution. This cooling solution is energy efficient, non-water-consumptive, and utilizes long duration energy storage (LDES) on both diurnal and seasonal time scales. Cold UTES has the potential to also function as a virtual power plant (VPP). The US Department of Energy's Geothermal Technologies Office is supporting R&D to understand the grid and system-wide value, costs, and impacts of deploying this emergent cooling solution at scale.

AI↗

Nuclear Thermal Rocket Element Environmental Simulator (NTREES)

To support a potential future development of a nuclear thermal rocket engine, a state-of-the-art non nuclear experimental test setup has been constructed to evaluate the performance characteristics of candidate fuel element materials and geometries in representative environments. The test device simulates the environmental conditions (minus the radiation) to which nuclear rocket fuel components could be subjected during reactor operation. Test articles mounted in the simulator are inductively heated in such a manner as to accurately reproduce the temperatures and heat fluxes normally expected to occur as a result of nuclear fission while at the same time being exposed to flowing hydrogen. This project is referred to as the Nuclear Thermal Rocket Element Environment Simulator or NTREES. The NTREES device is located at the Marshall Space flight Center in a laboratory which has been modified to accommodate the high powers required to heat the test articles to the required temperatures and to handle the gaseous hydrogen flow required for the tests. Other modifications to the laboratory include the installation of a nitrogen gas supply system and a cooling water supply system. During the design and construction of the facility, every effort was made to comply with all pertinent regulations to provide assurance that the facility could be operated in a safe and efficient manner. The NTREES system can currently supply up to 50 kW of inductive heating to the fuel test articles, although the facility has been sized to eventually allow test article heating levels of up to several megawatts.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗