Search NASA⌕ Search

SEARCH · Search NASA

Results for “Data evaluation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Nuclear Data Sheets for A = 210

Evaluated spectroscopic data for {sup 210}Au, {sup 210}Hg, {sup 210}Tl, {sup 210}Pb, {sup 210}Bi, {sup 210}Po, {sup 210}At, {sup 210}Rn, {sup 210}Fr, {sup 210}Ra, {sup 210}Ac, and {sup 210}Th and corresponding level schemes from radioactive decay and reaction studies are presented. This evaluation supersedes the previous evaluation by E. Browne (2003Br13). Highlights of this publication are the identification of new μs isomers of {sup 210}Hg by 2013Go10 and measurement of an excited level energy at 1709 keV 30 of {sup 210}Rn from {sup 214}Rn α decay: 68.6 μs by 2006Ku26 denoted as x+1664.6 in the Adopted Levels. Earlier experimental limits for x≤50 keV was proposed in 1979Po19 and 1982Po03 – (HI,xnγ)

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Money Matters: A Three-Step Process for Using Budget Data in Program Evaluation to Assess the Design and Management of a Novel Public Health Program

We applied a three-step process, abstracting and analyzing program budgets to examine how Colorectal Cancer Control Program (CRCCP) awardees are structuring their programs and to assess the fidelity of program design to the CRCCP public health model. We reviewed 23 state, one tribal organization, and six university awardee budgets. We assessed resource allocations, staffing structures, and contracted partners and their activities. Awardees allocated 83% of all funds to contracts and personnel. Program managers were the most budgeted personnel type across three measures: number of people, full-time equivalency, and personnel costs. Awardees not only contracted with health care systems and clinics (39% of all contracts) but also contracted other partner types. Contractors were mainly funded to implement evidence-based interventions (25%) and conduct evaluation (24%). Program design varied among awardees in the number of staff (0–22), number of full-time equivalencies (0–5.4), and the number of contracts (1–11) budgeted. State awardees budgeted more resources to contracts, compared with university awardees (57% vs. 31%), while universities budgeted more for total personnel costs (41% vs. 30%). We learned that awardees designed their programs with fidelity to the CRCCP model. Although implementation approaches varied, overall results suggest implementation requires a combination of internal capacities and contracted partners. Budgets provide opportunities to use already existing program data to evaluate program design, partnerships, and planned activities.

Uhd, Justin↗

Bayesian Monte Carlo Evaluation Framework for Cross Sections Nuclear Data and Integral Benchmark Experiments

The new Bayesian Monte Carlo (MC) evaluation framework described in this abstract has been conceived as an attempt to improve nuclear data evaluations of differential crosssection data by removing the following two approximations conventionally employed for nuclear data evaluations: all probability density functions (PDFs) of all data and model parameters, both prior and posterior, are assumed to be normal (i.e., Gaussian) PDFs, and all uncertainties and covariances are propagated using a linear approximation. With these approximations removed, the Bayesian MC (BMC) framework could be used to account for nonlinear effects and would enable improved evaluations of differential cross sections and IBE data that are presently performed based on the assumptions itemized above. The BMC would also improve upon the uniform sampling of IBE parameters from within ranges defined by their evaluated uncertainties.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Data reduction and evaluation procedures

The computational procedures that are involved in exhaust emissions data reduction and the use of these computational procedures for determining the quality of the data that is obtained from exhaust measurements were considered. Four problem areas were calculated: (1) the various methods for performing the carbon balance, (2) the method for calculating water correction factors, (3) the method for calculating the exhaust molecular weight, and (4) assessing the quality of the data.

Mirsky, W.↗

Apparatus and method for safety analysis evaluation with data-driven workflow

An apparatus and method for system safety analysis evaluation is provided, the apparatus including processing circuitry configured for generating a calculation matrix for a system, generating a plurality of models based on the calculation matrix, performing a benchmarking or convolution analysis of the plurality of models, identifying a design envelope based on the benchmarking or convolution analysis, deriving uncertainty models from the benchmarking or convolution analysis, deriving an assessment judgment based on the uncertainty models and acceptance criteria, defining one or more limiting scenarios based on the design envelope, and determining a safety margin in at least one figure-of-merit for the system based on the design envelope and the acceptance criteria.

Martin, Robert P.↗

Apparatus and method for safety analysis evaluation with data-driven workflow

An apparatus and method for system safety analysis evaluation is provided, the apparatus including processing circuitry configured for generating a calculation matrix for a system, generating a plurality of models based on the calculation matrix, performing a benchmarking or convolution analysis of the plurality of models, identifying a design envelope based on the benchmarking or convolution analysis, deriving uncertainty models from the benchmarking or convolution analysis, deriving an assessment judgment based on the uncertainty models and acceptance criteria, defining one or more limiting scenarios based on the design envelope, and determining a safety margin in at least one figure-of-merit for the system based on the design envelope and the acceptance criteria.

Martin, Robert P.↗

A Global Agroclimatology Solar Insolation and Meteorological Parameter Data Base: Meteorological Evaluation and Application Updates to NASA POWER

NASA’s Prediction of Worldwide Energy Resource (POWER) project facilitates the use of NASA Earth Science data holdings within the energy, agricultural, and architectural industries. POWER packages solar and meteorological data at various temporal levels from several NASA projects in a user friendly GIS-enabled web services system (https://power.larc.nasa.gov). Among other possible formats, data users can request POWER data in a column formatted DSSAT ASCII format by entering single site-specific coordinates or from an area by entering the appropriate area coordinate bounds. We present here recent evaluations of the POWER meteorological data through comparisons with global surface site measurements. While most meteorological parameters are taken from the NASA Modern Era Retrospective-analysis for Research and Applications (MERRA-2) data set, an alternate precipitation source from Integrated Multi-satellitE Retrievals for GPM (IMERG) is available and included in this evaluation. Expected updates to both IMERG and solar insolation sources will be evaluated as they become available.

J. Colleen Mikovitz↗

A First Evaluation of LANDSAT TM Data to Monitor Suspended Sediments in Lakes

A comparison was made between ground data collected from Lake Chicot, Arkansas, and Thematic Mapper (TM) data collected on September 23, 1982. A preliminary analysis of limited data indicate tht Thematic Mapper data may be useful in monitoring suspended sediment and chlorophyll in a lake with high suspended sediment loads. Total suspended loads ranged from 168 to 508 mg/l. TM Band 3 appears to be most useful with Bands 1, 2 and 4 also containing useful information relative to suspended sediments. Considering water data only, Bands 1, 2 and 3 appear to provide similar information. Bands 3 and 4 are also significantly related. Bands 5 and 7 appear to have independent information content relative to the presence or absence of water. Insufficient range of water temperature ground truth data made an evaluation of TM Band 6 difficult.

Schiebe, F. R.↗

Nuclear Data: From Measurement, Evaluation, Processing to Practical Applications [Slides]

Any analysis, design of a nuclear system will be as good as the knowledge of the nuclear data used whether differential and integral. ORNL is engaged in generating high level nuclear data for reactor, shielding, and safety applications. Nuclear data remains a major source of data uncertainties. Uncertainties on nuclear data rely upon measurements and evaluations. Tight connections with experimental facilities around the world have helped ORNL to address issues on ND and uncertainty. It is extremely important for ORNL to retain expertise on nuclear data in support of the research and expertise activities.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Nuclear Data Sheets for A = 247

Available information pertaining to the nuclear structure of all nuclei with mass numbers A=247 is presented. Various decay and reaction data are evaluated and compared. Adopted data, levels, spin, parity and configuration assignments are given. When there are insufficient data, expected values from systematics of nuclear properties or/and theoretical calculations are quoted. Unexpected or discrepant experimental results are also noted. A summary and compilation of the discovery of various isotopes in this mass region is given in 2013Fr02 ({sup 247}Pu, {sup 247}Am, {sup 247}Cm, {sup 243}Bk, {sup 247}Cf), 2011Me01 ({sup 247}Es), and 2013Th02 ({sup 247}Fm, {sup 247}Md)

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

ENDF/B-VIII.0: the 8. major release of the ENDF/B library containing CIELO-project evaluations, new standards and thermal scattering data - 25580

The ENDF/B-VIII.0 evaluated nuclear reaction data library was released on February 2, 2018. ENDF/B-VIII.0 incorporates many improvements including the new IAEA standards, a nearly completely new thermal neutron scattering sublibrary and the CIELO project evaluations for neutron reactions on {sup 16}O, {sup 56}Fe, {sup 235}U, {sup 238}U and {sup 239}Pu. These evaluations are a direct result of improvements in theory and simulation and benefit from recent experimental data obtained in the U.S. and Europe. Notable other advances include updated evaluated data for light nuclei, structural materials, actinides and charged-particle reactions, and specific updates to fission energy release, prompt fission neutron and γ-ray spectra. ENDF/B-VIII.0 has undergone substantial testing including a wide range of criticality, reaction rate, and shielding benchmarks. Our integral validation demonstrates that performance of the library is a noticeable improvement over the previous ENDF/B-VII.1 library. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

ERTS image data compression technique evaluation

The author has identified the following significant results. Tapes of compressed ERTS data were obtained to permit later reconstruction and to prove that in general four ERTS MSS tapes can be put onto a single compressed tape. A compressed tape was reconstructed and imagery made. The data were compressed using the essentially information preserving SSDIAM algorithm, with mappings of from 1 to 3 levels and imagery was made of the result. This imagery shows that no visual degradation results from the one level mapping while compression is significantly increased. Mappings of up to three levels shows negligible deterioration in areas of moderate to high data activity, but contouring is noticeable in areas of uniform data such as the plains region.

Spencer, D. J.↗

ERTS image data compression technique evaluation

The background and results of an investigation concerning the use of multispectral data compression in the ERTS program are presented. An average compression of greater than 2:1 has been achieved under the constraint of zero distortion in the reconstructed image, and four MSS tapes can be compressed to fill less than one reel of magnetic tape. A preliminary study of the hardware implementation of this processor proves the feasability of compression at input bit rates of over 100Mbs.

May, C. L.↗

Evaluation of Data-Driven Models for Predicting Solar Photovoltaics Power Output

This research was undertaken to evaluate different inverse models for predicting power output of solar photovoltaic (PV) systems under different practical scenarios. In particular, we have investigated whether PV power output prediction accuracy can be improved if module/cell temperature was measured in addition to climatic variables, and also the extent to which prediction accuracy degrades if solar irradiation is not measured on the plane of array but only on a horizontal surface. We have also investigated the significance of different independent or regressor variables, such as wind velocity and incident angle modifier in predicting PV power output and cell temperature. The inverse regression model forms have been evaluated both in terms of their goodness-of-fit, and their accuracy and robustness in terms of their predictive performance. Given the accuracy of the measurements, expected CV-RMSE of hourly power output prediction over the year varies between 3.2% and 8.6% when only climatic data are used. Depending on what type of measured climatic and PV performance data is available, different scenarios have been identified and the corresponding appropriate modeling pathways have been proposed. The corresponding models are to be implemented on a controller platform for optimum operational planning of microgrids and integrated energy systems.

14 SOLAR ENERGY↗

OBO Foundry in 2021: operationalizing open data principles to evaluate ontologies

Biological ontologies are used to organize, curate and interpret the vast quantities of data arising from biological experiments. While this works well when using a single ontology, integrating multiple ontologies can be problematic, as they are developed independently, which can lead to incompatibilities. The Open Biological and Biomedical Ontologies (OBO) Foundry was created to address this by facilitating the development, harmonization, application and sharing of ontologies, guided by a set of overarching principles. One challenge in reaching these goals was that the OBO principles were not originally encoded in a precise fashion, and interpretation was subjective. Here, we show how we have addressed this by formally encoding the OBO principles as operational rules and implementing a suite of automated validation checks and a dashboard for objectively evaluating each ontology’s compliance with each principle. This entailed a substantial effort to curate metadata across all ontologies and to coordinate with individual stakeholders. We have applied these checks across the full OBO suite of ontologies, revealing areas where individual ontologies require changes to conform to our principles. Our work demonstrates how a sizable, federated community can be organized and evaluated on objective criteria that help improve overall quality and interoperability, which is vital for the sustenance of the OBO project and towards the overall goals of making data Findable, Accessible, Interoperable, and Reusable (FAIR).

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

The AME2016 atomic mass evaluation (I). Evaluation of input data; and adjustment procedures

This paper is the first of two articles (Part I and Part II) that presents the results of the new atomic mass evaluation, Ame2016. It includes complete information on the experimental input data (also including unused and rejected ones), as well as details on the evaluation procedures used to derive the tables of recommended values given in the second part. This article describes the evaluation philosophy and procedures that were implemented in the selection of specific nuclear reaction, decay and mass-spectrometric results. These input values were entered in the least-squares adjustment for determining the best values for the atomic masses and their uncertainties. Details of the calculation and particularities of the Ame are then described. All accepted and rejected data, including outweighted ones, are presented in a tabular format and compared with the adjusted values obtained using the least-squares fit analysis. Differences with the previous Ame2012 evaluation are discussed and specific information is presented for several cases that may be of interest to Ame users. The second Ame2016 article gives a table with the recommended values of atomic masses, as well as tables and graphs of derived quantities, along with the list of references used in both the Ame2016 and the Nubase2016 evaluations (the first paper in this issue). Amdc: http://amdc.impcas.ac.cn/

Ame↗