Search NASA⌕ Search

SEARCH · Search NASA

Results for “Diffractive”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

KOTOBUKI-1 apparatus for cryogenic coherent X-ray diffraction imaging

We have developed an experimental apparatus named KOTOBUKI-1 for use in coherent X-ray diffraction imaging experiments of frozen-hydrated non-crystalline particles at cryogenic temperature. For cryogenic specimen stage with small positional fluctuation for a long exposure time of more than several minutes, we here use a cryogenic pot cooled by the evaporation cooling effect for liquid nitrogen. In addition, a loading device is developed to bring specimens stored in liquid nitrogen to the specimen stage in vacuum. The apparatus allows diffraction data collection for frozen-hydrated specimens at 66 K with a positional fluctuation of less than 0.4 μm and provides an experimental environment to easily exchange specimens from liquid nitrogen storage to the specimen stage. The apparatus was developed and utilized in diffraction data collection of non-crystalline particles with dimensions of μm from material and biological sciences, such as metal colloid particles and chloroplast, at BL29XU of SPring-8. Recently, it has been applied for single-shot diffraction data collection of non-crystalline particles with dimensions of sub-μm using X-ray free electron laser at BL3 of SACLA.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Single photon energy dispersive x-ray diffraction

With the pressure range accessible to laser driven compression experiments on solid material rising rapidly, new challenges in the diagnosis of samples in harsh laser environments are emerging. When driving to TPa pressures (conditions highly relevant to planetary interiors), traditional x-ray diffraction techniques are plagued by increased sources of background and noise, as well as a potential reduction in signal. In this paper we present a new diffraction diagnostic designed to record x-ray diffraction in low signal-to-noise environments. By utilising single photon counting techniques we demonstrate the ability to record diffraction patterns on nanosecond timescales, and subsequently separate, photon-by-photon, signal from background. In doing this, we mitigate many of the issues surrounding the use of high intensity lasers to drive samples to extremes of pressure, allowing for structural information to be obtained in a regime which is currently largely unexplored.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dynamic grazing incidence fast atom diffraction during molecular beam epitaxial growth of GaAs

A Grazing Incidence Fast Atom Diffraction (GIFAD) system has been mounted on a commercial molecular beam epitaxy chamber and used to monitor GaAs growth in real-time. In contrast to the conventionally used Reflection High Energy Electron Diffraction, all the GIFAD diffraction orders oscillate in phase, with the change in intensity related to diffuse scattering at step edges. We show that the scattered intensity integrated over the Laue circle is a robust method to monitor the periodic change in surface roughness during layer-by-layer growth, with oscillation phase and amplitude independent of incidence angle and crystal orientation. When there is a change in surface reconstruction at the start of growth, GIFAD intensity oscillations show that there is a corresponding delay in the onset of layer-by-layer growth. In addition, changes in the relative intensity of different diffraction orders have been observed during growth showing that GIFAD has the potential to provide insight into the preferential adatom attachment sites on the surface reconstruction during growth.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Six-axis multi-anvil press for high-pressure, high-temperature neutron diffraction experiments

We developed a six-axis multi-anvil press, ATSUHIME, for high-pressure and high-temperature in situ time-of-flight neutron powder diffraction experiments. The press has six orthogonally oriented hydraulic rams that operate individually to compress a cubic sample assembly. Experiments indicate that the press can generate pressures up to 9.3 GPa and temperatures up to 2000 K using a 6-6-type cell assembly, with available sample volume of about 50 mm{sup 3}. Using a 6-8-type cell assembly, the available conditions expand to 16 GPa and 1273 K. Because the six-axis press has no guide blocks, there is sufficient space around the sample to use the aperture for diffraction and place an incident slit, radial collimators, and a neutron imaging camera close to the sample. Combination of the six-axis press and the collimation devices realized high-quality diffraction pattern with no contamination from the heater or the sample container surrounding the sample. This press constitutes a new tool for using neutron diffraction to study the structures of crystals and liquids under high pressures and temperatures.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Influence of quantum diffraction and shielding on electron-ion collision in two-component semiclassical plasmas

The influence of quantum diffraction and shielding on the electron-ion collision process is investigated in two-component semiclassical plasmas. The eikonal method and micropotential taking into account the quantum diffraction and shielding are used to obtain the eikonal scattering phase shift and the eikonal collision cross section as functions of the collision energy, density parameter, Debye length, electron de Broglie wavelength, and the impact parameter. The result shows that the quantum diffraction and shielding effects suppress the eikonal scattering phase shift as well as the differential eikonal collision cross section, especially, in small-impact parameter regions. It is also shown that the quantum shielding effect on the eikonal collision cross section is more important in low-collision energies. In addition, it is found that the eikonal collision cross section increases with an increase in the density parameter. The variations of the eikonal cross section due to the quantum diffraction and shielding effects are also discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Diffractive, inelastic and total cross sections in high energy pp, pA and γ*A reactions with the dipole formalism

The Lund Monte Carlo model DIPSY has recently been extended to ions to study elastic, inelastic and diffractive processes in high energy collisions between electrons, protons and nuclei. In this BFKL-based dipole formalism of parton interactions fluctuations are naturally included and adding them to the pomeron ladder substantially determine the diffractive excitation cross sections of the processes. Starting from √(s{sub NN})=200 GeV and √(s{sub γ*N})=100 GeV we provide results for pp, pA and γ*A total, inelastic and diffractive cross sections that are shown and discussed in case of pp, pO, pCu, pPb and γ*Au reactions. We find good agreement with pp and pPb data. We find that the diffractive cross sections are relatively small compared to the total ones but with increasing collision energies they grow faster than the elastic or the inelastic ones. We make a comparison to calculations obtained by the more conventional method of the Glauber Model MC, too.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Significance of accurate diffraction corrections for the second harmonic wave in determining the acoustic nonlinearity parameter

The accurate measurement of acoustic nonlinearity parameter β for fluids or solids generally requires making corrections for diffraction effects due to finite size geometry of transmitter and receiver. These effects are well known in linear acoustics, while those for second harmonic waves have not been well addressed and therefore not properly considered in previous studies. In this work, we explicitly define the attenuation and diffraction corrections using the multi-Gaussian beam (MGB) equations which were developed from the quasilinear solutions of the KZK equation. The effects of making these corrections are examined through the simulation of β determination in water. Diffraction corrections are found to have more significant effects than attenuation corrections, and the β values of water can be estimated experimentally with less than 5% errors when the exact second harmonic diffraction corrections are used together with the negligible attenuation correction effects on the basis of linear frequency dependence between attenuation coefficients, α{sub 2} ≃ 2α{sub 1}.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Focal construct geometry for high intensity energy dispersive x-ray diffraction based on x-ray capillary optics

We presented a focal construct geometry (FCG) method for high intensity energy dispersive X-ray diffraction by utilizing a home-made ellipsoidal single-bounce capillary (ESBC) and a polycapillary parallel X-ray lens (PPXRL). The ESBC was employed to focus the X-rays from a conventional laboratory source into a small focal spot and to produce an annular X-ray beam in the far-field. Additionally, diffracted polychromatic X-rays were confocally collected by the PPXRL attached to a stationary energy-resolved detector. Our FCG method based on ESBC and PPXRL had achieved relatively high intensity diffraction peaks and effectively narrowed the diffraction peak width which was helpful in improving the potential d-spacing resolution for material phase analysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Measurement of diffractive dijet production at the H1 experiment

The new results on measurement of dijet production in diffractive deep inelastic ep scattering, ep → eXY, obtained with the H1 detector are presented. The system X contains at least two jets. Measurements are performed using two approaches. One approach is based on detection of the diffractive processes with Y being a proton or its low mass excitation. Diffractive events are selected by demanding a large empty rapidity gap interval separating the final state hadronic systems X and Y. In another approach, the leading final state proton from the process ep → eXp is detected in the H1 Very Forward Proton Spectrometer. The measurements are compared with predictions from NLO QCD calculations based on diffractive parton densities.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Three-dimensionally modulated anisotropic structure for diffractive optical elements created by one-step three-beam polarization holographic photoalignment

A diffractive optical element with a three-dimensional liquid crystal (LC) alignment structure for advanced control of polarized beams was fabricated by a highly efficient one-step photoalignment method. This study is of great significance because different two-dimensional continuous and complex alignment patterns can be produced on two alignment films by simultaneously irradiating an empty glass cell composed of two unaligned photocrosslinkable polymer LC films with three-beam polarized interference beam. The polarization azimuth, ellipticity, and rotation direction of the diffracted beams from the resultant LC grating widely varied depending on the two-dimensional diffracted position and the polarization states of the incident beams. These polarization diffraction properties are well explained by theoretical analysis based on Jones calculus.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A secondary diffraction effect and the generation of Scholte–Stoneley acoustic wave on periodically corrugated surface

When a wideband sound beam is incident onto a periodically corrugated surface, a series of diffraction related phenomena can occur. In this work, we report the observation of a secondary diffraction, which is different from those previously investigated. The search of the physical origin of this newly observed diffraction leads to the discovery of the possibility of generating Scholte–Stoneley waves, inspired by Guo, Margetan, and Thompson's work in sound backscattering from rough surfaces, through a nonconventional energy conversion mechanism: direct coupling of the incident energy with the periodic interface. This mechanism allows for the Scholte–Stoneley wave generation at any angle of incidence, which distinguishes it from the well-known energy conversion mechanism of the diffraction-related phenomena such as acoustic Wood anomaly and backward displacement in which wave generation is highly angle dependent. The findings of this work not only enrich the understanding of the interaction of sound with periodically corrugated structures but also provide a new surface wave generation method for the potential applications in nondestructive evaluation of materials.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Calculated efficiencies of three-material low stress coatings for diffractive x-ray transmission optics

Diffractive X-ray optical elements made by thin film coating techniques such as multilayer Laue lenses (MLL) and multilayer zone plates (MZP) are promising approaches to achieve resolutions in hard X-ray microscopy applications of less than 10 nm. The challenge is to make a lens with a large numerical aperture on the one hand and a decent working distance on the other hand. One of the limiting factors with the coated structures is the internal stress in the films, which can lead to significant bending of the substrate and various types of unwanted diffraction effects. Several approaches have been discussed to overcome this challenge. One of these is a three-material combination such as Mo/MoSi{sub 2}/Si, where four single layers per period are deposited. Mo and Si represent the absorber and spacer in this case while MoSi{sub 2} forms a diffusion barrier; in addition the thicknesses of absorber and spacer are chosen to minimize residual stress of the overall coating. Here the diffraction efficiency as well as the profile of the beam in the focal plane are discussed in order to find a tradeoff between lowest residual stress and best diffraction properties.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Experimental evaluation of enhancement of diffraction efficiency by overcoating diamond-like carbon (DLC) on soft x-ray laminar-type gratings

Efficiently detecting the B-K emission band around 6.76 nm from a trace concentration of boron in steel compounds has motivated a theoretical exploration of means of increasing the diffraction efficiency of a laminar grating with carbon overcoating. To experimentally evaluate this enhancement, a Ni grating was coated with a high-density carbon film, i.e., diamond-like carbon (DLC). The first order diffraction efficiencies of the Ni gratings coated with and without DLC were measured to be 25.8 % and 16.9 %, respectively, at a wavelength of 6.76 nm and an angle of incidence of 87.07°. The ratio of diffraction efficiency obtained experimentally vs. that calculated by numerical simulation is 0.87 for the DLC-coated Ni grating. The diffraction efficiency of a Ni grating coated with a low-density carbon film, amorphous carbon (a-C), was also slightly improved to be 19.6 %. Furthermore, a distinct minimum of the zeroth order lights of the two carbon-coated Ni gratings were observed at around 6.76 nm, which is coincident with the maximum of the first order light.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Diffraction efficiency of plasmonic gratings fabricated by electron beam lithography using a silver halide film

The silver nanoparticle surface relief gratings of ∼10 μm period are fabricated using electron beam lithography on the silver halide film substrate. Morphological characterization of the gratings shows that the period, the shape, and the relief depth in the gratings are mainly dependent on the number of lines per frame, the spot size, and the accelerating voltage of electron beam raster in the SEM. Optical absorption of the silver nanoparticle gratings provides a broad localized surface plasmon resonance peak in the visible region, whereas the intensity of the peaks depends on the number density of silver nanoparticles in the gratings. The maximum efficiency of ∼7.2% for first order diffraction is observed for the grating fabricated at 15 keV. The efficiency is peaking at 560 nm with ∼380 nm bandwidth. The measured profiles of the diffraction efficiency for the gratings are found in close agreement with the Raman-Nath diffraction theory. This technique provides a simple and efficient method for the fabrication of plasmonic nanoparticle grating structures with high diffraction efficiency having broad wavelength tuning.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Demonstration of femtosecond X-ray pump X-ray probe diffraction on protein crystals

The development of X-ray free-electron lasers (XFELs) has opened the possibility to investigate the ultrafast dynamics of biomacromolecules using X-ray diffraction. Whereas an increasing number of structures solved by means of serial femtosecond crystallography at XFELs is available, the effect of radiation damage on protein crystals during ultrafast exposures has remained an open question. We used a split-and-delay line based on diffractive X-ray optics at the Linac Coherent Light Source XFEL to investigate the time dependence of X-ray radiation damage to lysozyme crystals. For these tests, crystals were delivered to the X-ray beam using a fixed-target approach. The presented experiments provide probe signals at eight different delay times between 19 and 213 femtoseconds after a single pump event, thereby covering the time-scales relevant for femtosecond serial crystallography. Even though significant impact on the crystals was observed at long time scales after exposure with a single X-ray pulse, the collected diffraction data did not show significant signal reduction that could be assigned to beam damage on the crystals in the sampled time window and resolution range. This observation is in agreement with estimations of the applied radiation dose, which in our experiment was clearly below the values expected to cause damage on the femtosecond time scale. The experiments presented here demonstrate the feasibility of time-resolved pump-multiprobe X-ray diffraction experiments on protein crystals.

43 PARTICLE ACCELERATORS↗

Intermittent plasticity in individual grains: A study using high energy x-ray diffraction

Abstract Long-standing evidence suggests that plasticity in metals may proceed in an intermittent fashion. While the documentation of intermittency in plastically deforming materials has been achieved in several experimental settings, efforts to draw connections from dislocation motion and structure development to stress relaxation have been limited, especially in the bulk of deforming polycrystals. This work uses high energy x-ray diffraction measurements to build these links by characterizing plastic deformation events inside individual deforming grains in both the titanium alloy, Ti-7Al, and the magnesium alloy, AZ31. This analysis is performed by combining macroscopic stress relaxation data, complete grain stress states found using far-field high energy diffraction microscopy, and rapid x-ray diffraction spot measurements made using a Mixed-Mode Pixel Array Detector. Changes in the dislocation content within the deforming grains are monitored using the evolution of the full 3-D shapes of the diffraction spot intensity distributions in reciprocal space. The results for the Ti-7Al alloy show the presence of large stress fluctuations in contrast to AZ31, which shows a lesser degree of intermittent plastic flow.

36 MATERIALS SCIENCE↗

Deformation of binary and boron-doped Ni 3 Al alloys at high pressures studied with synchrotron x-ray diffraction

In situ x-ray synchrotron diffraction experiments were carried out on nickel-based high-strength superalloys under pressure to understand their deformation mechanism using a diamond anvil cell (DAC). Radial x-ray diffraction determines the room-temperature equations of state and yield strengths of binary Ni 3 Al alloy and 500 ppm boron-doped Ni 3 Al to pressures of 20 and 46 GPa, respectively. Crystallographic preferred orientations observed in these superalloys due to anisotropic stress field in DAC indicate the onset of plastic deformation. Inverse pole figure analysis reveals that the underlying deformation mechanisms change from an octahedral slip to a simultaneous activation of octahedral and cube slips upon doping with boron. The yield-strength values were found to increase with pressure and are comparable to those determined from axial diffraction experiments. The results indicate that the yield strength of Ni 3 Al:B is about 0.5 GPa higher (at pressures below 20 GPa) due to grain boundary strengthening by boron. It is shown that due to high elastic anisotropy of Ni 3 Al alloy, the yield-strength estimations from diffraction experiments strongly depend on the micromechanical model used to convert the measured elastic strains into stresses.

42 ENGINEERING↗

Intermolecular correlations of liquid and glassy CS 2 studied by synchrotron radiation x-ray diffraction

How is the orientation of molecular liquids ordered on cooling? What are the basic structures of molecular glasses, e.g., close to the crystalline structure or some special structures such as icosahedral cluster? These are long-standing questions in liquid and glass physics. Here, we have constructed a novel cryostat to prepare simple molecular glasses by vapor deposition and performed in situ synchrotron radiation x-ray diffraction experiments. The glassy state of a simple molecule CS 2 , which cannot be vitrified by normal liquid quenching, was successfully prepared with this instrument, and its diffraction data were collected in a wide Q-range of 0.16–25.7 Å -1 with a high-energy diffractometer at BL04B2, SPring-8. The diffraction data of liquid CS 2 were also recorded in a wide temperature range of 160–300 K. These diffraction data were analyzed with molecular dynamics simulations and reverse Monte Carlo modelings to investigate orientational correlation. From the obtained 3D structure models, the orientational correlation between neighboring CS 2 molecules was investigated quantitatively as a function of temperature. At room temperature, the parallel and T-shaped arrangements are preferred for the nearest neighbor correlation. On cooling, these arrangements are developed gradually, and its rate became prominent below the melting temperature (162 K). In the glassy state, the slipped-parallel arrangement is dominant as well as the T-shaped arrangement. Both arrangements appear in the CS 2 crystal, indicating that the structure of glassy CS 2 is close to that of crystalline CS 2 .

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗