Search NASA⌕ Search

SEARCH · Search NASA

Results for “ELECTROMAGNETIC INSTRUMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Effects of nonlinearity on the optical diffraction of Bose-Einstein condensates: Direct integration of optically coupled multicomponent Gross-Pitaevskii equation

We investigate in detail the effects of nonlinearity on optical diffraction of Bose-Einstein condensates (BECs). By directly integrating the optically coupled two-component Gross-Pitaevskii equation in real space-time, comprehensive analyses of BEC optical diffraction phenomena are done under various conditions of light-pulse irradiation, total number of BEC atoms, etc., without using the adiabatic elimination approximation for an atomic excited state. Calculation results for the optical diffraction of {sup 87}Rb BECs revealed that (1) the effect of nonlinearity on the atomic states causes the ''nonkinetic'' nonlinear effect in the Raman-Nath regime of diffraction, while the dynamics of BEC atoms due to the nonlinearity-induced repulsive forces works dominantly to produce the ''kinetic'' nonlinear effect in the Bragg regime of diffraction; (2) nonlinearity reduces the amplitude and frequency of the two-photon Rabi oscillation between BEC stationary and moving states, suggesting limitations in implementing the BEC Mach-Zehnder interferometer; and (3) the observed nonlinear effects are free from kinetic effects of the atomic excited state and not responsible for the optical transition process.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Lifetime measurements in {sup 63}Co and {sup 65}Co

Lifetimes of the 9/2{sub 1}{sup -} and 3/2{sub 1}{sup -} states in {sup 63}Co and the 9/2{sub 1}{sup -} state in {sup 65}Co were measured using the recoil distance Doppler shift and the differential decay curve methods. The nuclei were populated by multinucleon transfer reactions in inverse kinematics. {gamma} rays were measured with the EXOGAM Ge array and the recoiling fragments were fully identified using the large-acceptance VAMOS spectrometer. The E2 transition probabilities from the 3/2{sub 1}{sup -} and 9/2{sub 1}{sup -} states to the 7/2{sup -} ground state could be extracted in {sup 63}Co as well as an upper limit for the 9/2{sub 1}{sup -}{yields}7/2{sub 1}{sup -} B(E2) value in {sup 65}Co. The experimental results were compared to large-scale shell-model calculations in the pf and pfg{sub 9/2} model spaces, allowing us to draw conclusions on the single-particle or collective nature of the various states.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

B{sup (*)}B{sup (*)} intermediate states contribution to {Upsilon}(4S,5S){yields}{eta}{sub b}+{gamma} radiative decay

In this work, we investigate the rescattering effects in the radiative decay {Upsilon}(5S){yields}{eta}{sub b}+{gamma}, which were suggested to be crucially important for understanding the anomalous largeness of the branching ratios B({Upsilon}(5S){yields}{Upsilon}(1S)+{pi}{pi}) and B({Upsilon}(5S){yields}{Upsilon}(1S)+{eta}). Our calculations show that the rescattering effects may enhance {Gamma}({Upsilon}(10860){yields}{eta}{sub b}+{gamma}) by four orders, but the tetraquark structure does not. Recently the BABAR and CLEO collaborations have measured the mass of {eta}{sub b} and the branching ratios B({Upsilon}(2S){yields}{eta}{sub b}+{gamma}), B({Upsilon}(3S){yields}{eta}{sub b}+{gamma}). We hope that very soon, {Upsilon}(10860){yields}{eta}{sub b}+{gamma} will be measured and it would be an ideal opportunity for testing whether the rescattering or the tetraquark structure is responsible for the anomaly of B({Upsilon}(5S){yields}{Upsilon}(nS){pi}{sup +}{pi}{sup -}(n=1,2,3)), i.e., the future measurements on the radiative decays of {Upsilon}(5S) might be a touchstone of the two mechanisms.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Parametrized tests of post-Newtonian theory using Advanced LIGO and Einstein Telescope

General relativity has very specific predictions for the gravitational waveforms from inspiralling compact binaries obtained using the post-Newtonian (PN) approximation. We investigate the extent to which the measurement of the PN coefficients, possible with the second generation gravitational-wave detectors such as the Advanced Laser Interferometer Gravitational-Wave Observatory (LIGO) and the third generation gravitational-wave detectors such as the Einstein Telescope (ET), could be used to test post-Newtonian theory and to put bounds on a subclass of parametrized-post-Einstein theories which differ from general relativity in a parametrized sense. We demonstrate this possibility by employing the best inspiralling waveform model for nonspinning compact binaries which is 3.5PN accurate in phase and 3PN in amplitude. Within the class of theories considered, Advanced LIGO can test the theory at 1.5PN and thus the leading tail term. Future observations of stellar mass black hole binaries by ET can test the consistency between the various PN coefficients in the gravitational-wave phasing over the mass range of 11-44M{sub {center_dot}}. The choice of the lower frequency cutoff is important for testing post-Newtonian theory using the ET. The bias in the test arising from the assumption of nonspinning binaries is indicated.

79 ASTRONOMY AND ASTROPHYSICS↗

Saturation amplitude of the f-mode instability

We investigate strong nonlinear damping effects which occur during high amplitude oscillations of neutron stars, and the gravitational waves they produce. For this, we use a general relativistic nonlinear hydrodynamics code in conjunction with a fixed spacetime (Cowling approximation) and a polytropic equation of state (EOS). Gravitational waves are estimated using the quadrupole formula. Our main interest are l=m=2 f modes subject to the CFS (Chandrasekhar, Friedman, Schutz) instability, but we also investigate axisymmetric and quasiradial modes. We study various models to determine the influence of rotation rate and EOS. We find that axisymmetric oscillations at high amplitudes are predominantly damped by shock formation, while the nonaxisymmetric f modes are mainly damped by wave breaking and, for rapidly rotating models, coupling to nonaxisymmetric inertial modes. From the observed nonlinear damping, we derive upper limits for the saturation amplitude of CFS-unstable f modes. Finally, we estimate that the corresponding gravitational waves for an oscillation amplitude at the upper limit should be detectable with the advanced LIGO (Laser Interferometer Gravitational Wave Observatory) and VIRGO interferometers at distances above 10 Mpc. This strongly depends on the stellar model, in particular, on the mode frequency.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Maximum gravitational-wave energy emissible in magnetar flares

Recent searches of gravitational-wave data raise the question of what maximum gravitational-wave energies could be emitted during gamma-ray flares of highly magnetized neutron stars (magnetars). The highest energies ({approx}10{sup 49} erg) predicted so far come from a model [K. Ioka, Mon. Not. R. Astron. Soc. 327, 639 (2001), http://adsabs.harvard.edu/abs/2001MNRAS.327..639I] in which the internal magnetic field of a magnetar experiences a global reconfiguration, changing the hydromagnetic equilibrium structure of the star and tapping the gravitational potential energy without changing the magnetic potential energy. The largest energies in this model assume very special conditions, including a large change in moment of inertia (which was observed in at most one flare), a very high internal magnetic field, and a very soft equation of state. Here we show that energies of 10{sup 48}-10{sup 49} erg are possible under more generic conditions by tapping the magnetic energy, and we note that similar energies may also be available through cracking of exotic solid cores. Current observational limits on gravitational waves from magnetar fundamental modes are just reaching these energies and will beat them in the era of advanced interferometers.

79 ASTRONOMY AND ASTROPHYSICS↗

Detecting concealed objects at a checkpoint

Disclosed are systems, methods, devices, and apparatus to interrogate a clothed individual with electromagnetic radiation to determine if a concealed object is being carried. This determination includes establishing data corresponding to an image of the individual with a pair of opposed, semi-cylindrical array panels each configured to interrogate the individual with electromagnetic radiation in the 200 MHz to 1 THz range.

47 OTHER INSTRUMENTATION↗

A synthetic diagnostic for validation of electron gyroradius scale turbulence simulations against coherent scattering measurements

Comparison between spectra of short-scale density fluctuations measured with coherent electromagnetic scattering experiments and those extracted from space-resolved numerical simulations is affected by a number of systematic errors. These include the locality of scattering measurements, the different domain covered (space-resolved simulations versus wavenumber resolved measurements), and the stationarity of simulated nonlinear spectra. To bridge the gap between theory-simulations and experiments, a synthetic diagnostic for high- k scattering measurements has been developed. This synthetic scattering predicts the propagation of the beam in an anisotropic, inhomogeneous plasma and accounts for the spatial variation of the instrumental transfer function. Here the latter, in particular, is proven to provide an important calibration factor not only for the simulated spectra, but also for the measured ones, allowing the use of the synthetic diagnostic in predictive mode. Results from a case study for National Spherical Torus Experiment plasmas using high- k</em. tangential scattering system and the gyrokinetic tokamak simulation code are presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Perspectives on Gamma-Ray Pulsar Emission

Pulsars are powerful sources of radiation across the electromagnetic spectrum. This paper highlights some theoretical insights into non-thermal, magnetospheric pulsar gamma-ray radiation. These advances have been driven by NASA's Fermi mission, launched in mid-2008. The Large Area Telescope (LAT) instrument on Fermi has afforded the discrimination between polar cap and slot gap/outer gap acceleration zones in young and middle-aged pulsars. Altitude discernment using the highest energy pulsar photons will be addressed, as will spectroscopic interpretation of the primary radiation mechanism in the LAT band, connecting to both polar cap/slot gap and outer gap scenarios. Focuses will mostly be on curvature radiation and magnetic pair creation, including population trends that may afford probes of the magnetospheric accelerating potential.

79 ASTRONOMY AND ASTROPHYSICS↗

X-Ray Measurements Of A Thermo Scientific P385 DD Neutron Generator

Idaho National Laboratory is experimenting with electrical neutron generators, as potential replacements for californium-252 radioisotopic neutron sources in its PINS prompt gamma-ray neutron activation analysis (PGNAA) system for the identification of military chemical warfare agents and explosives. In addition to neutron output, we have recently measured the x-ray output of the Thermo Scientific P385 deuterium-deuterium neutron generator. X rays are a normal byproduct from neutron generators, but depending on their intensity and energy, x rays can interfere with gamma rays from the object under test, increase gamma-spectrometer dead time, and reduce PGNAA system throughput. The P385 x-ray energy spectrum was measured with a high-purity germanium (HPGe) detector, and a broad peak is evident at about 70 keV. To identify the source of the x rays within the neutron generator assembly, it was scanned by collimated scintillation detectors along its long axis. At the strongest x-ray emission points, the generator also was rotated 60 deg. between measurements. The scans show the primary source of x-ray emission from the P385 neutron generator is an area 60 mm from the neutron production target, in the vicinity of the ion source. Rotation of the neutron generator did not significantly alter the x-ray count rate, and its x-ray emission appears to be axially symmetric. A thin lead shield, 3.2 mm (1/8 inch) thick, reduced the 70-keV generator x rays to negligible levels.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Integration of an Atomic Force Microscope in a Beamline Sample Environment

We developed and optimised an optics-free Atomic Force Microscope (AFM) that can be directly installed on most of the synchrotron radiation end-stations. The combination of Scanning Probe Microscopies with X-ray microbeams adds new possibilities to the variety of synchrotron radiation techniques. The instrument can be used for atomic force imaging of the investigated sample or to locally measure the X-ray absorption or diffraction, or it can also be used to mechanically interact with the sample while simultaneously taking spectroscopy or diffraction measurements. The local character of these measurements is intrinsically linked with the use of the Atomic Force Microscope tip. It is the sharpness of the tip that gives the opportunity to measure the photons flux impinging on it giving beam position monitor features, or allows to locally measure the absorption coefficient or the shape of the diffraction pattern. As an example of the possibilities opened by the instrument we will show diffraction measurements performed on a Ge/Si island while being indented with the AFM tip providing local measure of the Young coefficient. Three ESRF beamlines are going to be equipped with this new instrument.

43 PARTICLE ACCELERATORS↗

Suppression criteria of parasitic mode oscillations in a gyrotron beam tunnel

This paper presents the design criteria of the parasitic mode oscillations suppression for a periodic, ceramic, and copper loaded gyrotron beam tunnel. In such a type of beam tunnel, the suppression of parasitic mode oscillations is an important design problem. A method of beam-wave coupling coefficient and its mathematical formulation are presented. The developed design criteria are used in the beam tunnel design of a 42 GHz gyrotron to be developed for the Indian TOKAMAK system. The role of the thickness and the radius of the beam tunnel copper rings to obtain the developed design criteria are also discussed. The commercially available electromagnetic code CST and the electron trajectory code EGUN are used for the simulations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Impact of instrumental systematics on the CMB bispectrum

We study the effects of instrumental systematics on the estimation of primordial non-Gaussianity using the cosmic microwave background (CMB) bispectrum from both the temperature and the polarization anisotropies. For temperature systematics we consider gain fluctuation and beam distortions. For polarization we consider effects related to known instrumental systematics: calibration, pixel rotation, differential gain, pointing, and ellipticity of the instrument beam. We consider these effects at the next to leading order, which we refer to as nonlinear systematic effects. We find that if the instrumental response is linearly proportional to the received CMB intensity, then only the shape of the primordial CMB bispectrum, if there is any, will be distorted. We show that the nonlinear response of the instrument can in general result in spurious non-Gaussian features on both the CMB temperature and polarization anisotropies, even if the primordial CMB is completely Gaussian. We determine the level for both the linear and nonlinear systematics parameters for which they would cause no significant degradation of our ability to constrain the primordial non-Gaussianity amplitude f{sub NL}. We find that the nonlinear systematics are potentially a bigger worry for extracting the primordial non-Gaussianity than the linear systematics, especially because the current and near future CMB probes are optimized for CMB power-spectrum measurements which are not particularly sensitive to the nonlinear instrument response. We find that if instrumental nonlinearities are not controlled by dedicated calibration, the effective local non-Gaussianity can be as large as f{sub NL}{approx}O(10) before the corresponding nonlinearities show up in the CMB dipole measurements. The higher-order multipoles are even less sensitive to instrumental nonlinearities.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Laser-driven deflection arrangements and methods involving charged particle beams

Systems, methods, devices and apparatus are implemented for producing controllable charged particle beams. In one implementation, an apparatus provides a deflection force to a charged particle beam. A source produces an electromagnetic wave. A structure, that is substantially transparent to the electromagnetic wave, includes a physical structure having a repeating pattern with a period L and a tilted angle .alpha., relative to a direction of travel of the charged particle beam, the pattern affects the force of the electromagnetic wave upon the charged particle beam. A direction device introduces the electromagnetic wave to the structure to provide a phase-synchronous deflection force to the charged particle beam.

47 OTHER INSTRUMENTATION↗

Calibration and performance of the ATLAS Tile Calorimeter during the LHC Run 2

The Tile Calorimeter (TileCal) is the hadronic sampling calorimeter of the ATLAS experiment at the Large Hadron Collider (LHC). TileCal uses iron absorbers and scintillators as active material and it covers the central region | η| < 1.7. Jointly with the other sub-detectors it is designed for measurements of hadrons, jets, tau-particles and missing transverse energy. It also assists in muon identification. TileCal is regularly monitored and calibrated by several different calibration systems: a Cs radioactive source, a laser light system to check the PMT response, and a charge injection system (CIS) to check the front-end electronics. These calibration systems, in conjunction with data collected during proton-proton collisions, Minimum Bias (MB) events, provide extensive monitoring of the instrument and a means for equalizing the calorimeter response at each stage of the signal propagation. The performance of the calorimeter has been established with cosmic ray muons and the large sample of the proton-proton collisions and compared to Monte Carlo (MC) simulations. The response of high momentum isolated muons is also used to study the energy response at the electromagnetic scale, isolated hadrons are used as a probe of the hadronic response. The calorimeter time resolution is studied with multijet events. A description of the different TileCal calibration systems and the results on the calorimeter performance during the LHC Run 2 are introduced. The findings on the pile-up noise and response uniformity studies are also reported on.

47 OTHER INSTRUMENTATION↗

DEGREE-SCALE GeV 'JETS' FROM ACTIVE AND DEAD TeV BLAZARS

We show that images of TeV blazars in the GeV energy band should contain, along with point-like sources, degree-scale jet-like extensions. These GeV extensions are the result of electromagnetic cascades initiated by TeV {gamma}-rays interacting with extragalactic background light and the deflection of the cascade electrons/positrons in extragalactic magnetic fields (EGMFs). Using Monte Carlo simulations, we study the spectral and timing properties of the degree-scale extensions in simulated GeV band images of TeV blazars. We show that the brightness profile of such degree-scale extensions can be used to infer the light curve of the primary TeV {gamma}-ray source over the past 10{sup 7} yr, i.e., over a time scale comparable to the lifetime of the parent active galactic nucleus. This implies that the degree-scale jet-like GeV emission could be detected not only near known active TeV blazars, but also from 'TeV blazar remnants', whose central engines were switched off up to 10 million years ago. Since the brightness profile of the GeV 'jets' depends on the strength and the structure of the EGMF, their observation provides additional information about the EGMF.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A diagnostic system for electrical faults in a high current discharge plasma setup

A diagnostic system to detect electrical faults inside a coaxial high current discharge device is presented here. This technique utilizes two biconical antennas picking up electromagnetic radiation from the discharge device, a voltage divider sensing input voltage, and a Rogowski coil measuring the main discharge current. A computer program then analyses frequency components in these signals and provides information as to whether the discharge event was normal or any breakdown fault occurred inside the coaxial device. The diagnostic system is developed for a 450 kV and 50 kA capillary discharge plasma setup. For the setup various possible faults are analyzed by electrical simulation, followed by experimental results. In the case of normal discharge through the capillary load the dominant frequency is {approx}4 MHz. Under faulty conditions, the peak in magnitude versus frequency plot of the antenna signal changes according to the fault position which involves different paths causing variation in the equivalent circuit elements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Method for analyzing ExB probe spectra from Hall thruster plumes

Various methods for accurately determining ion species' current fractions using ExB probes in Hall thruster plumes are investigated. The effects of peak broadening and charge exchange on the calculated values of current fractions are quantified in order to determine the importance of accounting for them in the analysis. It is shown that both peak broadening and charge exchange have a significant effect on the calculated current fractions over a variety of operating conditions, especially at operating pressures exceeding 10{sup -5} torr. However, these effects can be accounted for using a simple approximation for the velocity distribution function and a one-dimensional charge exchange correction model. In order to keep plume attenuation from charge exchange below 30%, it is recommended that pz{<=}2, where p is the measured facility pressure in units of 10{sup -5} torr and z is the distance from the thruster exit plane to the probe inlet in meters. The spatial variation of the current fractions in the plume of a Hall thruster and the error induced from taking a single-point measurement are also briefly discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗