Search NASA⌕ Search

SEARCH · Search NASA

Results for “EVACUATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

The case for a Martian origin of the shergottites. II - Trapped and indigenous gas components in EETA 79001 glass

The isotopic composition of N, Ar, Ne, and He, trapped in an uncrushed sample of the antarctic shergottite EETA 79001, was analyzed by subjecting the evacuated sample to stepped heating in the presence of 100 mtorr of oxygen. The isotopic composition of nitrogen (with the delta-N-15 value of greater than 300 percent) and the elemental ratios Ar-36/N-14 and Ar-40/N-14 were covariant along mixing lines passing through the Martian atmospheric composition. The results of this and previous analyses are consistent with a two-component nitrogen system in which about 84 ppb of trapped Martian atmospheric N is mixed in variable proportions with another, more thermally labile N component during stepped heating. The isotopic Ar-36/Ar-38 ratio of the EETA 79001 is different from that of the earth atmosphere by about 25 percent.

Wiens, R. C.↗

Vertical structure of Arctic haze observed by lidar

In the study of the Arctic Haze phenomenon, understanding the vertical structure of the haze aerosol is crucial in defining mechanisms of haze transport. Questions have also arisen concerning the representativeness of surface observations of Arctic Haze. Due to the strongly stratified nature of the Arctic troposphere, the mechanisms which transport aerosol to the surface from the transport altitudes of the lower troposphere are not obvious. In order to examine these questions, a Mie scattering lidar was installed at Alert, NWT, Canada. Lidar observes atmospheric aerosols and hydrymeteors as they appear in nature, unmodified by sampling effects. As such the results obtained are more realistic of the light scattering characteristics of the in situ aerosol than are those obtained by integrating nephelometers, for example, which heat the aerosol and dry it before measurement. With this lidar, a pulse was transmitted vetically through an evacuated tube in the roof of a building at Alert. The receiver consisted of a 20cm diameter Fresnel telescope, neutral density and polarizing filters, and RCA C31000A PMT, Analog Modules LA-90-P logarithmic amplifier and a Lecroy TR8827 32 MHz digitizer. The lidar equation was solved for the backscattering coefficient of the aerosol assuming no two way transmission losses in the signal. The lidar results have shown that intercomparison between lidar obtained visibilities and observer visibilities are in much better agreement than for other optical or aerosol monitors. Three new effects were identified in the lidar profiles which contribute to the vertical transport of haze. These effects are briefly discussed.

Hoff, R. M.↗

Experimental evaluation of wall Mach number distributions of the octagonal test section proposed for NASA Lewis Research Center's altitude wind tunnel

Wall Mach number distributions were determined over a range of test-section free-stream Mach numbers from 0.2 to 0.92. The test section was slotted and had a nominal porosity of 11 percent. Reentry flaps located at the test-section exit were varied from 0 (fully closed) to 9 (fully open) degrees. Flow was bled through the test-section slots by means of a plenum evacuation system (PES) and varied from 0 to 3 percent of tunnel flow. Variations in reentry flap angle or PES flow rate had little or no effect on the Mach number distributions in the first 70 percent of the test section. However, in the aft region of the test section, flap angle and PES flow rate had a major impact on the Mach number distributions. Optimum PES flow rates were nominally 2 to 2.5 percent wtih the flaps fully closed and less than 1 percent when the flaps were fully open. The standard deviation of the test-section wall Mach numbers at the optimum PES flow rates was 0.003 or less.

Harrington, Douglas E.↗

Aircraft accident report: NASA 712, Convair 990, N712NA, March Air Force Base, California, July 17, 1985, facts and analysis

On July 17, l985, at 1810 P.d.t., NASA 712, a Convair 990 aircraft, was destroyed by fire at March Air Force Base, California. The fire started during the rollout after the pilot rejected the takeoff on runway 32. The rejected takeoff was initiated during the takeoff roll because of blown tires on the right landing gear. During the rollout, fragments of either the blown tires or the wheel/brake assemblies penetrated a right-wing fuel tank forward of the right main landing gear. Leaking fuel ignited while the aircraft was rolling, and fire engulfed the right wing and the fuselage after the aircraft was stopped on the runway. The 4-man flightcrew and the 15 scientists and technicians seated in the cabin evacuated the aircraft without serious injury. The fire was not extinguished by crash/rescue efforts and the aircraft was destroyed.

Batthauer, Byron E.↗

Pulsed source of energetic atomic oxygen

A pulsed high flux source of nearly monoenergetic atomic oxygen was designed, built, and successfully demonstrated. Molecular oxygen at several atmospheres pressure is introduced into an evacuated supersonic expansion nozzle through a pulsed molecular beam valve. An 18 J pulsed CO2 TEA laser is focused to intensities greater than 10(9) W/sq cm in the nozzle throat to generate a laser-induced breakdown. The resulting plasma is heated in excess of 20,000 K by a laser supported detonation wave, and then rapidly expands and cools. Nozzle geometry confines the expansion to provide rapid electron-ion recombination into atomic oxygen. Average O atom beam velocities from 5 to 13 km/s were measured at estimated fluxes to 10(18) atoms per pulse. Preliminary materials testing has produced the same surface oxygen enrichment in polyethylene samples as obtained on the STS-8 mission. Scanning electron microscope examinations of irradiated polymer surfaces reveal an erosion morphology similar to that obtained in low Earth orbit, with an estimated mass removal rate of approx. 10(-24) cu cm/atom. The characteristics of the O atom source and the results of some preliminary materials testing studies are reviewed.

Caledonia, George E.↗

Energetic oxygen atom material degradation studies

As part of a study designed to test potential Shuttle surface materials for the extents of degradation and mass loss expected to be suffered in space from the velocity impacts of ambient oxygen atoms, a novel technique was developed for generation of a high flux of energetic oxygen atoms. The generation technique involves laser-induced breakdown of molecular oxygen followed by a rapid expansion of energetic oxygen atoms. The high-velocity streams developed in an evacuated hypersonic nozzle have average O-atom velocities of about 5 to 13 km/s, with an estimated total production of 10 to the 18th atoms per pulse over pulse durations of several microseconds. Results on preliminary material degradation tests conducted with this test facility have been reported by Caledonia et al. (1987). Diagrams of the experimental setup are included.

Caledonia, George E.↗

Measurement of methane and other light hydrocarbons in the troposphere and lower stratosphere

The volume mixing ratios of methane, acetylene, ethane, and propane were measured in the troposphere and stratosphere on April 5, 1984, at 33 deg N, over New Mexico, using the technique of grab sampling by evacuated spheres on a balloon platform. Tropospheric volume mixing ratios were CH4, 1.59 ppm; C2H2, 358 ppt (parts per trillion); C2H6, 365 ppt; and C3H8, 1440 ppt. In the stratosphere, acetylene was 60 ppt. For ethane and propane the mixing ratios at 11.6 km were 441 ppt and 84 ppt, respectively.

Aikin, A. C.↗

A high flux pulsed source of energetic atomic oxygen

The design and demonstration of a pulsed high flux source of nearly monoenergetic atomic oxygen are reported. In the present test setup, molecular oxygen under several atmospheres of pressure is introduced into an evacuated supersonic expansion nozzle through a pulsed molecular beam valve. A 10J CO2 TEA laser is focused to intensities greater than 10 to the 9th W/sq cm in the nozzle throat, generating a laser-induced breakdown with a resulting 20,000-K plasma. Plasma expansion is confined by the nozzle geometry to promote rapid electron-ion recombination. Average O-atom beam velocities from 5-13 km/s at fluxes up to 10 to the 18th atoms/pulse are measured, and a similar surface oxygen enrichment in polyethylene samples to that obtained on the STS-8 mission is found.

Krech, Robert H.↗

Hollow cathodes for arcjet thrusters

In an attempt to prevent exterior spot emission, hollow cathode bodies and orifice plates were constructed from boron nitride which is an electrical insulator, but the orifice plates melted and/or eroded at high interelectrode pressures. The most suitable hollow cathodes tested included a refractory metal orifice plate in a boron nitride body, with the insert insulated electrically from the orifice plate. In addition, the hollow cathode interior was evacuated to assure a low pressure at the insert surface, thus promoting diffuse electron emission. At high interelectrode pressures, the electrons tended to flow through the orifice plate rather than through the orifice, which could result in overheating of the orifice plate. Using a carefully aligned centerline anode, electron flow through the orifice could be sustained at interelectrode pressures up to 500 torr - but the current flow path still occasionally jumped from the orifice to the orifice plate. Based on these tests, it appears that a hollow cathode would operate most effectively at pressures in the arcjet regime with a refractory, chemically stable, and electrically insulating cathode body and orifice plate.

Luebben, Craig R.↗

Bipolar flows, molecular gas disks, and the collapse and accretion of rotating interstellar clouds

Rigorous numerical models of the collapse and accretion of rotating, axisymmetric, isothermal interstellar clouds are studied. The results show that molecular gas disks and evacuated bipolar cavities both appear to be natural consequences of the collapse of rotating interstellar clouds. Dynamically significant magnetic fields may not be necessary for explaining either phenomenon. The models strongly support theoretical models of the type where an isotropic wind from a pre-main sequence star is extrinsically collimated by a rotationally derived molecular gas cloud. The models imply that collimation should be strongest on small scales where rotational effects are most important, i.e., in the dense region of the molecular gas disk.

Boss, Alan P.↗

Development and test of the Shuttle/Centaur cryogenic tankage thermal protection system

The Thermal Protection System (TPS) for the Shuttle/Centaur had to provide fail-safe thermal protection during prelaunch, launch ascent, and on-orbit operations as well as during potential abort where the Shuttle and Centaur would return to earth. The TPS selected used a helium-purged polyimide foam beneath three radiation shields for the liquid hydrogen (LH2) tank and radiation shields only for the liquid oxygen (LO2) tank (three shields on the tank sidewall and four on the aft bulkhead). An evacuated common intermediate bulkhead separated the two tanks. The LH2 tank had one 1.9-cm thick layer of foam on the forward bulkhead and two layers on the larger area side-wall. Full scale tests of the flight vehicle in a simulated Shuttle cargo bay, that was purged with gaseous nitrogen, gave total prelaunch heating rates of 25.9 kW and 12.9 kW for LH2 and LO2 tanks, respectively. Calorimeter tests on a representative LH2 tank sidewall TPS sample indicated that the measured unit heating rate would rapidly decrease from the prelaunch rate of 300 W/sq m to a desired rate of less than 4 W/sq m once on-orbit.

Knoll, R. H.↗

Measurement of emissivity of industrial surfaces using a simple method

To detect emissivity, the drop in temperature of the sample undergoing radiation exchange with the wall in an evacuated space is measured over a given period. In this manner, emissivities of various synthetic resin lacquers, metals, and metallic coatings were measured. Once the emissivity is known, the same method can be used to detect specific heat and the head condition of gases.

Dallmeyer, H.↗

Method of evaporation

Liquids, such as juices, milk, molten metal and the like are concentrated by forming uniformly-sized, small droplets in a precision droplet forming assembly and deploying the droplets in free fall downwardly as a central column within an evacuated column with cool walls. A portion of the solvent evaporates. The vapor flows to the wall, condenses, and usually flows down the wall as a film to condensate collector and drain. The vertical column of freely falling droplets enters the splash guard. The condensate can be collected, sent to other towers or recycled.

Dufresne, Eugene R.↗

An improved external recycle reactor for determining gas-solid reaction kinetics

These improvements in the recycle system effectively eliminate initial concentration variation by two modifications: (1) a vacuum line connection to the recycle loop which permits this loop to be evacuated and then filled with the test gas mixture to slightly above atmospheric pressure; and (2) a bypass line across the reactor which permits the reactor to be held under vacuum while the rest of the recycle loop is filled with test gas. A three-step procedure for bringing the feed gas mixture into contact with the catalyst at time zero is described.

Miller, Irvin M.↗

Power meter for optical efficiency measurements of laser-induced plasmas

A power meter was constructed to measure the power being deposited in transient laser-induced plasmas (LIP). The design rejects the radiation scattered from the laser beam by the LIP and that transmitted past the LIP. The power meter is constructed from a small metal-capped flask placed in an evacuated chamber. The steady-state heat production in the flask is determined from measurements of the temperature gradient on a thermal resistance connecting the top of the flask with a heat sink. The design worked well and should be applicable to a wide variety of situations if the dimensions of the system are adjusted to compensate for power levels substantially different from those used here.

Borucki, William J.↗

Magnetic fields interacting with nonlinear compressible convection

Two-dimensional numerical simulations are used to study fully compressible convection in the presence of an imposed magnetic field. Highly nonlinear flows are considered that span multiple density scale heights. The convection tends to sweep the initially uniform vertical magnetic field into concentrated flux sheets with significant magnetic pressures. These flux sheets are partially evacuated, and effects of buoyancy and Lorentz forces there can serve to suppress motions. The flux sheets can be surrounded by a sheath of descending flow. If the imposed magnetic field is sufficiently strong, the convection can become oscillatory. The unstably stratified fluid layer has an initial density ratio (bottom to top of layer) of 11. Surveys of solutions at fixed Rayleigh number sample Chandrasekhar numbers from 1 to 1000 and magnetic Prandtl numbers from 1/16 to 1. These nonlinear simulations utilize a two-dimensional numerical scheme based on a modified two-step Lax-Wendroff method.

Hulburt, Neal E.↗

Simulation of electron distributions within auroral acceleration regions

Plasma data from the Dynamics Explorer 1 satellite are used to investigate the electron distributions found within regions of parallel potential drops. A computer simulation was developed to predict major features of the observed electron distributions found within these regions. The simulation results are discussed and compared with observations. Good agreement is observed only when the potential distribution along the field line is split into separate potential drops, one above and one below the satellite. The simulated electron distribution exhibits a trapped particle region, the formation of the electron hole, and the evacuation of the loss cone.

Gurgiolo, C.↗

High Temperature Gas-Gap Thermal Switch

Device set to allow heat to flow across gap (switch "on") or decrease rate of transfer of heat to relatively low value (switch "off"). Operates at temperatures in approximate range of 100 to 1,500 degree C. Central cylindrical object thermally connected to (or disconnected from) environment by filling gap between inner and outer sleeves of switch (or evacuating gap) to increase (or decrease) thermal conduction across gap.

Bard, Steven↗