Search NASA⌕ Search

SEARCH · Search NASA

Results for “Failure Rate”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Failures of CMOS Circuits Irradiated At Low Rates

Report describes experiments on irradiation of SGS 4007 complementary metal oxide/semiconductor (CMOS) integrated inverter circuits by 60Co and 137Cs radioactive sources. Purpose of experiments to supplement previous observations that minimum radiation doses at which failure occurred in more-complicated CMOS parts were lower at lower dose rates.

Goben, Charles A.↗

Prior to failure extension of flaws in a rate sensitive Tresca solid.

Theoretical analysis shows that the amount of slow growth occurring prior to fracture in a plane stress tension specimen subjected to a subcritical stress intensity level is affected by the ductility and rheological sensitivity of the material, the rate of loading, the initial crack size, and the geometrical configuration of the test. These parameters enter the governing nonlinear differential equation which describes the quasi-static crack extension in a rate-sensitive Tresca solid. Examples of numerical integration are given and employed to predict the maximum fracture toughness attained in a plane stress tension test.

Wnuk, M. P.↗

Loading rate sensitivity of open hole composites in compression

The results are reported of an experimental study on the compressive, time-dependent behavior of graphite fiber reinforced polymer composite laminates with open holes. The effect of loading rate on compressive strength was determined for six material systems ranging from brittle epoxies to thermoplastics at both 75 F and 220 F. Specimens were loaded to failure using different loading rates. The slope of the strength versus elapsed time-to-failure curve was used to rank the materials' loading rate sensitivity. All of the materials had greater strength at 75 F than at 220 F. All the materials showed loading rate effects in the form of reduced failure strength for longer elapsed-time-to-failure. Loading rate sensitivity was less at 220 F than the same material at 70 F. However, C12000/ULTEM and IM7/8551-7 were more sensitive to loading rate than the other materials at 220 F. AS4/APC2 laminates with 24, 32, and 48 plies and 1/16 and 1/4 inch diameter holes were tested. The sensitivity to loading rate was less for either increasing number of plies or larger hole size. The failure of the specimens made from brittle resins was accompanied by extensive delaminations while the failure of the roughened systems was predominantly by shear crippling. Fewer delamination failures were observed at the higher temperature.

Lubowinski, Steve J.↗

Loading rate sensitivity of open-hole composite specimens in compression

The results are reported of an experimental study on the compressive, time-dependent behavior of graphite fiber reinforced polymer composite laminates with open holes. The effect of loading rate on compressive strength was determined for six material systems ranging from brittle epoxies to thermoplastics at both 75 F and 220 F. Specimens were loaded to failure using different loading rates. The slope of the strength versus elapsed time-to-failure curve was used to rank the materials' loading rate sensitivity. All of the materials had greater strength at 75 F than at 220 F. All the materials showed loading rate effects in the form of reduced failure strength for longer elapsed-time-to-failure. Loading rate sensitivity was less at 220 F than the same material at 70 F. However, C12000/ULTEM and IM7/8551-7 were more sensitive to loading rate than the other materials at 220 F. AS4/APC2 laminates with 24, 32, and 48 plies and 1/16 and 1/4 inch diameter holes were tested. The sensitivity to loading rate was less for either increasing number of plies or larger hole size. The failure of the specimens made from brittle resins was accompanied by extensive delaminations while the failure of the roughened systems was predominantly by shear crippling. Fewer delamination failures were observed at the higher temperature.

Lubowinski, S. J.↗

Ceramic capacitor insulation resistance failures accelerated by low voltage

Ceramic capacitors failed insulation resistance testing at less than one-tenth their rated voltage. Many failures recovered as the voltage was increased. Comprehensive failure analysis techniques, some of which are unprecedented, were used to examine these failures. It was determined that there was more than one failure mechanism, and the results indicate a need for special additional screening.

Brennan, T. F.↗

Alternative Dose for Choroidal Melanoma Treated With an Iodine-125 Radioactive Plaque: A Single-Institution Retrospective Study

Purpose: The Collaborative Ocular Melanoma Study (COMS) established iodine-125 plaque brachytherapy as an accepted standard treatment for medium-size choroidal melanoma. In the COMS, the prescription dose was 85 Gy. This is a retrospective review of our outcomes in patients treated with lower doses than those used in the COMS. Methods and Materials: From 1990 to 2004, 62 patients were treated with iodine-125 plaque brachytherapy for choroidal melanoma. COMS eye plaques were used with dose prescribed to the apex of the tumor. The median and average dose rates at the tumor apex were 63.5 cGy/h and 62.7 cGy/h, respectively. The median and average total doses were 63.0 Gy and 62.5 Gy (range, 56-69 Gy), respectively. The median and mean durations of implant were 100.0 hours and 101.1 hours (range, 71-165 hours). Results: Median follow-up time was 58.2 months. The 5-year outcomes including overall survival, disease-free survival, cause-specific survival, local failure, secondary enucleation rate, and visual acuity (VA) <20/200 were estimated using the Kaplan-Meier method. Overall, there were 7 local failures, 4 distant failures, and 10 secondary enucleations (6 due to local failure and 4 due to treatment complications). Univariate analysis was performed to identify significant prognostic factors associated with disease-free survival (baseline VA in tumor eye, tumor shape), cause-specific survival (diabetic retinopathy), local failure (none found), secondary enucleation rate (diabetic retinopathy, basal tumor dimension) and VA <20/200 (diabetic retinopathy, tumor shape, age, retinal detachment, treatment depth, and history of vision-limiting condition). Conclusions: Our survival and local control outcomes are comparable to those of the COMS. However, VA at 5 years seems to be better. Lower doses of radiation could potentially lead to better visual outcomes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

MO-G-BRE-09: Validating FMEA Against Incident Learning Data: A Study in Stereotactic Body Radiation Therapy

Purpose: Though FMEA (Failure Mode and Effects Analysis) is becoming more widely adopted for risk assessment in radiation therapy, to our knowledge it has never been validated against actual incident learning data. The objective of this study was to perform an FMEA analysis of an SBRT (Stereotactic Body Radiation Therapy) treatment planning process and validate this against data recorded within an incident learning system. Methods: FMEA on the SBRT treatment planning process was carried out by a multidisciplinary group including radiation oncologists, medical physicists, and dosimetrists. Potential failure modes were identified through a systematic review of the workflow process. Failure modes were rated for severity, occurrence, and detectability on a scale of 1 to 10 and RPN (Risk Priority Number) was computed. Failure modes were then compared with historical reports identified as relevant to SBRT planning within a departmental incident learning system that had been active for two years. Differences were identified. Results: FMEA identified 63 failure modes. RPN values for the top 25% of failure modes ranged from 60 to 336. Analysis of the incident learning database identified 33 reported near-miss events related to SBRT planning. FMEA failed to anticipate 13 of these events, among which 3 were registered with severity ratings of severe or critical in the incident learning system. Combining both methods yielded a total of 76 failure modes, and when scored for RPN the 13 events missed by FMEA ranked within the middle half of all failure modes. Conclusion: FMEA, though valuable, is subject to certain limitations, among them the limited ability to anticipate all potential errors for a given process. This FMEA exercise failed to identify a significant number of possible errors (17%). Integration of FMEA with retrospective incident data may be able to render an improved overview of risks within a process.

60 APPLIED LIFE SCIENCES↗

A Nonlocal Progressive Damage Model for Composite Materials

Fiber reinforced composite materials are widely used in aerospace structures due to their high specific stiffness and strength. These materials exhibit complex deformation, damage and failure mechanisms under high strain rate loading conditions. Many different failure criteria have been proposed in literature to describe the damage initiation and evolution of fiber reinforced composite materials. Most of these damage models are based on a local framework. In a local framework, the material behavior is based on a point-wise constitutive relation which is independent of the effect of the surrounding points. These models include stiffness degradation when damage initiates in the material, which within a local framework leads to a highly mesh dependent result. This could be overcome using a nonlocal finite element approach. In the current work, a nonlocal formulation based on the work by Andrade et al [1] is adapted to describe composite material behavior. The LS-DYNA rate dependent progressive damage model, MAT162 is employed to detect the initiation and evolution of damage in orthotropic composite materials. This model is developed as a FORTRAN user material subroutine in the LS-DYNA environment. The results of MAT162 with and without the nonlocal formulation are compared at different mesh densities to validate the model. The numerical analysis exhibits the advantages of the nonlocal formulation.

Kodagali, Karan↗

Malignant Tumors of the Nasal Cavity and Paranasal Sinuses: Long-Term Outcome and Morbidity With Emphasis on Hypothalamic-Pituitary Deficiency

Purpose: To evaluate the long-term outcome after surgery and radiotherapy for patients with sinonasal cancer and assess late toxicity, with special emphasis on hypothalamic-pituitary dysfunction. Methods and Materials: A retrospective analysis of 168 patients treated for sinonasal cancer in a single institute between 1986 and 2006. A more detailed analysis was performed on a subgroup of 76 patients with adenocarcinoma or squamous cell carcinoma treated with curative intent. Long-term survivors were evaluated for late toxicity by a multidisciplinary team using the late effects of normal tissues (LENT SOMA) scoring system. Additional endocrinologic tests were performed for assessment of hypothalamic-pituitary function. Results: Five-year actuarial local control and overall survival rates were 62% and 35% for all patients and 64% and 42% for the subgroup with squamous cell carcinoma and adenocarcinoma. In multivariate analysis, T stage was the only significant factor predicting local relapse (79% at 5 years for T1-T3 vs. 53% for T4; p = 0.006). Sinonasal mucosal melanomas had the highest rate of regional failure (33% at 5 years). Thirteen of 21 patients (62%) evaluated at the late morbidity clinic had hormonal disturbances, of whom 5 (24%) had definitive evidence of hypopituitarism with multiple hormonal deficiencies. Conclusion: Local failure is the dominant cause of treatment failure for patients with sinonasal cancer, with T4 stage the only independent predictor. Because of a high rate of radiation-induced hypopituitarism, we recommend endocrinologic surveillance for these patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Future Liver Remnant Indocyanine Green Plasma Clearance Rate as a Predictor of Post-hepatectomy Liver Failure After Portal Vein Embolization

PurposeTo evaluate the utility of future liver remnant plasma clearance rate of indocyanine green (ICGK-F) for predicting post-hepatectomy liver failure (PHLF) compared with percentage future liver remnant volume-to-total liver volume ratio (%FLR) after portal vein embolization (PVE).Materials and MethodsPVE procedures in 20 patients (15 patients underwent PVE with absolute ethanol; 5 patients with gelatin particles) from 2010 to 2017 were analyzed. %FLR = future liver remnant volume (ml)/[total liver volume (ml) − tumor volume (ml)] × 100; ICGK-F = plasma clearance rate of indocyanine green (ICGK) × %FLR/100 were calculated before and after PVE. PHLF was categorized according to the criteria of the International Study Group of Liver Surgery. For predicting PHLF, we compared the ICGK-F and %FLR after PVE between the grade A PHLF group and the non-grade A PHLF (grades B and C) group.ResultsAll PVE procedures were successful. While the ICGK-F of the grade A PHLF group (median 0.073, n = 16) was about twice that of the non-grade A PHLF group (median 0.043, n = 4), showing a significant difference (Mann–Whitney U test: P = 0.002), there was no significant difference in %FLR between the grade A PHLF group and the non-grade A PHLF group (Mann–Whitney U test: P = 0.335).ConclusionICGK-F was significantly higher in the grade A PHLF group than in the non-grade A PHLF group (grades B and C), and ICGK-F was more useful for predicting PHLF than %FLR.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Long-Term Outcome and Prognostic Factors for Adenocarcinoma/Adenosquamous Carcinoma of Cervix After Definitive Radiotherapy

Purpose: To study the outcomes of patients with adenocarcinoma/adenosquamous carcinoma (AC/ASC) of the cervix primarily treated with radiotherapy (RT), identify the prognostic factors, and evaluate the efficacy of concurrent chemoradiotherapy (CCRT) or salvage surgery. Methods and Materials: A total of 148 patients with Stage I-IVA AC/ASC of cervix after full-course definitive RT were included. Of the 148 patients, 77% had advanced stage disease. Treatment failure was categorized as either distant or local failure. Local failure was further separated into persistent tumor or local relapse after complete remission. The effectiveness of CCRT with cisplatin and/or paclitaxel was examined, and the surgical salvage rate for local failure was reviewed. Results: The 5-year relapse-free survival rate was 68%, 38%, 49%, 30%, and 0% for those with Stage IB/IIA nonbulky, IB/IIA bulky, IIB, III, and IVA disease, respectively, and appeared inferior to that of those with squamous cell carcinoma of the cervix treated using the same RT protocol. Incomplete tumor regression after RT, a low hemoglobin level, and positive lymph node metastasis were independent poor prognostic factors for relapse-free survival. CCRT with weekly cisplatinum did not improve the outcome for our AC/ASC patients. Salvage surgery rescued 30% of patients with persistent disease. Conclusion: Patients with AC/ASC of the cervix primarily treated with RT had inferior outcomes compared to those with squamous cell carcinoma. Incomplete tumor regression after RT was the most important prognostic factor for local failure. Salvage surgery for patients with persistent tumor should be encouraged for selected patients. Our results did not demonstrate a benefit of CCRT with cisplatin for this disease.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Rate-weakening friction characterizes both slow sliding and catastrophic failure of landslides

Significance A predictive understanding of landslide behavior remains elusive, to the extent that once landslide motion is detected the factors that control whether motion will remain slow or accelerate to catastrophic failure remain uncertain. Here, we adapt standard fault mechanics treatments to present a single model that captures both slow and catastrophic landslide motion. We test model predictions using field, laboratory, and remote sensing observations. The failure mode depends on the material properties and the dimensions of the landslide slip surface relative to a critical size. If the slip surface exceeds this size and has rate-weakening frictional properties then catastrophic failure must occur. However, landslides composed of rate-weakening material are characterized by slow sliding when the critical size exceeds landslide dimensions.

58 GEOSCIENCES↗

Experimental deformation of polycrystalline H2O ice at high pressure and low temperature - Preliminary results

A preliminary study is carried out of involving 70 constant strain deformation tests on pure polycrystalline H2O ice under conditions covering most of the stability field of ice I sub h. Brittle failure of I sub h is found to be promoted by lower P, lower T, and higher strain rates. Ductile flow is found to be promoted by higher P, higher T, and lower strain rates. The brittle failure of ice I sub h is found to be most unusual. The fracture strength is a positive function of P only below 50 MPa. At pressures greater than this, the fracture strength is independent of P, and the fracture plane lies approximately 45 deg from the load axis. It is believed that existing extrapolation based on existing experimental data to Ganymede and Callisto may be badly in error.

Durham, W. B.↗

Formation of 2D nanoparticles with block structure in simultaneous electric explosion of conductors

A molecular dynamics simulation of nanoparticle formation in simultaneous electric explosion of conductors is performed. Interatomic interaction is described using potentials calculated in the framework of the embedded atom method. High-rate heating results in failure of the conductors with the formation of nanoparticles. The influence of the heating rate, temperature distribution over the specimen cross-section and the distance between simultaneously exploded conductors on the structure of formed nanoparticles is studied. The calculation results show that the electric explosion of conductors allows the formation of nanoparticles with block structure.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Prone Accelerated Partial Breast Irradiation After Breast-Conserving Surgery: Five-year Results of 100 Patients

Purpose: To report the 5-year results of a prospective trial of three-dimensional conformal external beam radiotherapy (3D-CRT) to deliver accelerated partial breast irradiation in the prone position. Methods and Materials: Postmenopausal patients with Stage I breast cancer with nonpalpable tumors <2 cm, negative margins and negative nodes, positive hormone receptors, and no extensive intraductal component were eligible. The trial was offered only after eligible patients had refused to undergo standard whole-breast radiotherapy. Patients were simulated and treated on a dedicated table for prone setup. 3D-CRT was delivered at a dose of 30 Gy in five 6-Gy/day fractions over 10 days with port film verification at each treatment. Rates of ipsilateral breast failure, ipsilateral nodal failure, contralateral breast failure, and distant failure were estimated using the cumulative incidence method. Rates of disease-free, overall, and cancer-specific survival were recorded. Results: One hundred patients were enrolled in this institutional review board-approved prospective trial, one with bilateral breast cancer. One patient withdrew consent after simulation, and another patient elected to interrupt radiotherapy after receiving two treatments. Ninety-eight patients were evaluable for toxicity, and, in 1 case, both breasts were treated with partial breast irradiation. Median patient age was 68 years (range, 53-88 years); in 55% of patients the tumor size was <1 cm. All patients had hormone receptor-positive cancers: 87% of patients underwent adjuvant antihormone therapy. At a median follow-up of 64 months (range, 2-125 months), there was one local recurrence (1% ipsilateral breast failure) and one contralateral breast cancer (1% contralateral breast failure). There were no deaths due to breast cancer by 5 years. Grade 3 late toxicities occurred in 2 patients (one breast edema, one transient breast pain). Cosmesis was rated good/excellent in 89% of patients with at least 36 months follow-up. Conclusions: Five-year efficacy and toxicity of 3D-CRT delivered in prone partial breast irradiation are comparable to other experiences with similar follow-up.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Sci-Fri AM: Quality, Safety, and Professional Issues 05: QC Program Management and the Benefits of QATrack+

Purpose: Treatment unit uptime statistics are typically used to monitor radiation equipment performance. The Ottawa Hospital Cancer Centre has introduced the use of Quality Control (QC) test success as a quality indicator for equipment performance and overall health of the equipment QC program. Methods: Implemented in 2012, QATrack+ is used to record and monitor over 1100 routine machine QC tests each month for 20 treatment and imaging units ( http://qatrackplus.com/ ). Using an SQL (structured query language) script, automated queries of the QATrack+ database are used to generate program metrics such as the number of QC tests executed and the percentage of tests passing, at tolerance or at action. These metrics are compared against machine uptime statistics already reported within the program. Results: Program metrics for 2015 show good correlation between pass rate of QC tests and uptime for a given machine. For the nine conventional linacs, the QC test success rate was consistently greater than 97%. The corresponding uptimes for these units are better than 98%. Machines that consistently show higher failure or tolerance rates in the QC tests have lower uptimes. This points to either poor machine performance requiring corrective action or to problems with the QC program. Conclusions: QATrack+ significantly improves the organization of QC data but can also aid in overall equipment management. Complimenting machine uptime statistics with QC test metrics provides a more complete picture of overall machine performance and can be used to identify areas of improvement in the machine service and QC programs.

60 APPLIED LIFE SCIENCES↗

Uncertainty Quantification of Calculated Temperatures for the AGR 3/4 Experiment

A series of Advanced Gas Reactor (AGR) irradiation experiments are being conducted within the Advanced Reactor Technology (ART) Fuel Development and Qualification Program. The main objectives of the fuel experimental campaign are to provide the necessary data on fuel performance to support fuel process development, qualify a fuel design and fabrication process for normal operation and accident conditions, and support development and validation of fuel performance and fission product transport models and codes (PLN 3636, “Technical Program Plan for INL Advanced Reactor Technologies Technology Development Office/Advanced Gas Reactor Fuel Development and Qualification Program”). The AGR 3/4 test was inserted in the Northeast Flux Trap position in the Advanced Test Reactor (ATR) core at Idaho National Laboratory (INL) in December 2011 and successfully completed irradiation in mid-April 2014, resulting in irradiation of the tristructural isotropic (TRISO) fuel for 369.1 effective full-power days (EFPDs) during approximately 2.4 calendar years. The AGR 3/4 data, including the irradiation data and calculated results, were qualified and stored in the Nuclear Data Management and Analysis System (NDMAS). To support the U.S. TRISO fuel performance assessment and to provide data for validation of fuel performance and fission product transport models and codes, the daily as run thermal analysis has been performed separately on each of twelve AGR 3/4 capsules for the entire irradiation as discussed in ECAR-2807, “AGR 3/4 Daily As Run Thermal Analyses”. The ABAQUS code’s finite element-based thermal model predicts the daily average volume average (VA) fuel temperature (FT), peak FT, and graphite matrix, sleeve, and sink temperature in each capsule. The JMOCUP simulation codes were also created to perform depletion calculations for the AGR 3/4 experiment (ECAR-2753, “JMOCUP As-Run Daily Physics Depletion Calculation for the AGR 3/4 TRISO Particle Experiment in ATR Northeast Flux Trap”). This depletion analysis provides fast fluence and fission heat rate data for all components (fuel compacts, graphite rings, stainless steel retainer, etc.), which are used as inputs for the thermal analysis codes. The graphite temperatures from thermocouples (TCs) in each capsule were used to calibrate these thermal analysis codes. However, given the high rate of TC failure under the harsh irradiation and thermal conditions in the AGR capsules, the thermal analysis results are very useful in aiding TC data qualification, increasing the confidence in delineating failures of the measuring instruments (TCs) from physical mechanisms that may have shifted the system thermal response.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗