Search NASA⌕ Search

SEARCH · Search NASA

Results for “Frequency extraction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

On the detection of other planetary systems by astrometric techniques

A quantitative method for astrometrically detecting perturbations induced in a star's motion by the presence of a planetary object is described. A periodogram is defined, wherein signals observed from a star show exactly periodic variations, which can be extracted from observational data using purely statistical methods. A detection threshold is defined for the frequency of occurrence of some detectable signal, e.g., the Nyquist frequency. Possible effects of a stellar orbital eccentricity and multiple companions are discussed, noting that assumption of a circular orbit assures the spectral purity of the signal described. The periodogram technique was applied to 12 yr of astrometric data from the U.S. Naval Observatory for three stars with low mass stellar companions. Periodic perturbations were confirmed. A comparison of the accuracy of different astrometric systems shows that the detection accuracy of a system is determined by the measurement accuracy and the number of observations, although the detection efficiency can be maximized by minimizing the number of data points for the case when observational errors are proportional to the square root of the number of data points. It is suggested that a space-based astrometric telescope is best suited to take advantage of the method.

Black, D. C.↗

Covert laser remote sensing and vibrometry

Designs of single-beam laser vibrometry systems and methods. For example, a method for detecting vibrations of a target based on optical sensing is provided to include operating a laser to produce a laser probe beam at a laser frequency and modulated at a modulation frequency onto a target; collecting light at or near the laser to collect light from the target while the target is being illuminated by the laser probe beam through an optical receiver aperture; using a narrow-band optical filter centered at the laser frequency to filter light collected from the optical receiver aperture to transmit light at the laser frequency while blocking light at other frequencies; using an optical detector to convert filtered light from the narrow-band optical filter to produce a receiver electrical signal; using a lock-in amplifier to detect and amplify the receiver electrical signal at the modulation frequency while rejecting signal components at other frequencies to produce an amplified receiver electrical signal; processing the amplified receiver electrical signal to extract information on vibrations of the target carried by reflected laser probe beam in the collected light; and controlling optical power of the laser probe beam at the target to follow optical power of background illumination at the target.

Maleki, Lutfollah↗

Uniform DT 3T burn: computations and sensitivities

A numerical model was developed in C to integrate the nonlinear deutrium-tritium (DT) burn equations in a three temperature (3T) approximation for spatially uniform test problems relevant to Inertial Confinement Fusion (ICF). Base model results are in excellent agreement with standard 3T results. Data from NDI, SESAME, and TOPS databases is extracted to create fits for the reaction rate parameter, the Planck opacity, and the coupling frequencies of the plasma temperatures. The impact of different fits (e.g., TOPS versus SESAME opacity data, higher order polynomial fits ofNDI data for the reaction rate parameter) were explored, and sensitivity to several model inputs are presented including: opacity data base, Coulomb logarithm, and Bremsstrahlung. Sensitivity to numerical integration time step size, and the relative insensitivity to the discretized numerics and numerical integration method was demonstrated. Variations in the IC for densities and temperatures were explored, showing similar DT burn profiles in most cases once ignition occurs. A coefficient multiplying the Compton coupling term (default, A = 1) can be adjusted to approximate results from more sophisticated models. The coefficient was reset (A = 0.4) to match the maximum temperatures resulting from standard multi-group simulations of the base case test problem. Setting the coefficient to a larger value, (A = 0.6) matches maximum ion temperatures in a kinetic simulation of a high density ICF-like regime. Matching peak temperatures does not match entire temperature-time profiles, indicating the Compton coefficient is density and time dependent as the photon distribution evolves. In the early time burn during the ignition of the DT, the present model with modified Compton coupling provides a very simple method to obtain a much improved match to the more accurate solution from the multi-group radiation model for these DT burn regimes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Searching for cosmological stochastic backgrounds by notching out resolvable compact binary foregrounds with next-generation gravitational-wave detectors

Stochastic gravitational-wave backgrounds can be of either cosmological or astrophysical origin. The detection of an astrophysical stochastic gravitational-wave background with ground-based interferometers is expected in the near future. Perhaps even more excitingly, the detection of stochastic backgrounds of cosmological origin by future ground-based interferometers could reveal invaluable information about the early Universe. From this perspective, the astrophysical background is a {\it foreground} that can prevent the extraction of this information from the data. In this paper, we revisit a time-frequency domain notching procedure previously proposed to remove the astrophysical foreground in the context of next-generation ground-based detectors, but we consider the more realistic scenario where we remove individually detectable signals by taking into account the uncertainty in the estimation of their parameters. We find that time-frequency domain masks can still efficiently remove the astrophysical foreground and suppress it to about $5\%$ of its original level. Further removal of the foreground formed by unresolvable events (in particular, unresolvable binary neutron stars), which is about $10$ times larger than the residual foreground from realistic notching, would require detector sensitivity improvements. Therefore, the main limitation in the search for a cosmological background is the unresolvable foreground itself, and not the residual of the notching procedure.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Preliminary results on noncollocated torque control of space robot actuators

In the Space Station era, more operations will be performed robotically in space in the areas of servicing, assembly, and experiment tending among others. These robots may have various sets of requirements for accuracy, speed, and force generation, but there will be design constraints such as size, mass, and power dissipation limits. For actuation, a leading motor candidate is a dc brushless type, and there are numerous potential drive trains each with its own advantages and disadvantages. This experiment uses a harmonic drive and addresses some inherent limitations, namely its backdriveability and low frequency structural resonances. These effects are controlled and diminished by instrumenting the actuator system with a torque transducer on the output shaft. This noncollocated loop is closed to ensure that the commanded torque is accurately delivered to the manipulator link. The actuator system is modelled and its essential parameters identified. The nonlinear model for simulations will include inertias, gearing, stiction, flexibility, and the effects of output load variations. A linear model is extracted and used for designing the noncollocated torque and position feedback loops. These loops are simulated with the structural frequency encountered in the testbed system. Simulation results are given for various commands in position. The use of torque feedback is demonstrated to yield superior performance in settling time and positioning accuracy. An experimental setup being finished consists of a bench mounted motor and harmonic drive actuator system. A torque transducer and two position encoders, each with sufficient resolution and bandwidth, will provide sensory information. Parameters of the physical system are being identified and matched to analytical predictions. Initial feedback control laws will be incorporated in the bench test equipment and various experiments run to validate the designs. The status of these experiments is given.

Tilley, Scott W.↗

Aging Wire Insulation Assessment by Phase Spectrum Examination of Ultrasonic Guided Waves

Wire integrity has become an area of concern to the aerospace community including DoD, NASA, FAA, and Industry. Over time and changing environmental conditions, wire insulation can become brittle and crack. The cracks expose the wire conductor and can be a source of equipment failure, short circuits, smoke, and fire. The technique of using the ultrasonic phase spectrum to extract material properties of the insulation is being examined. Ultrasonic guided waves will propagate in both the wire conductor and insulation. Assuming the condition of the conductor remains constant then the stiffness of the insulator can be determined by measuring the ultrasonic guided wave velocity. In the phase spectrum method the guided wave velocity is obtained by transforming the time base waveform to the frequency domain and taking the phase difference between two waveforms. The result can then be correlated with a database, derived by numerical model calculations, to extract material properties of the wire insulator. Initial laboratory tests were performed on a simple model consisting of a solid cylinder and then a solid cylinder with a polymer coating. For each sample the flexural mode waveform was identified. That waveform was then transformed to the frequency domain and a phase spectrum was calculated from a pair of waveforms. Experimental results on the simple model compared well to numerical calculations. Further tests were conducted on aircraft or mil-spec wire samples, to see if changes in wire insulation stiffness can be extracted using the phase spectrum technique.

Anastasi, Robert F.↗

Alteration of volcanic rocks: A new non-intrusive indicator based on induced polarization measurements

Induced polarization is a geophysical method investigating the ability of rocks to store reversibly electrical charges under a slowly alternating electrical field. The material property of interest is a complex-valued electrical conductivity with an in-phase component associated with conduction and a quadrature component associated with polarization. Here we investigated the relationship between complex conductivity spectra over the frequency range 1 mHz–45 kHz and the specific surface area (SSA) of 28 volcanic core samples extracted from a wellbore drilled for the Humu'ula Groundwater Research Project in Hawaii. The specific surface area of these samples was determined through the Brunauer, Emmett and Teller (BET) method. Subcritical nitrogen adsorption experiments were conducted using two different instruments and the samples were prepared in both pellets and powder forms. The BET specific surface area is found to be highly correlated to the cation exchange capacity of the core samples measured by the cobalthexamine method. The in-phase conductivity itself can be decomposed as the sum of a bulk contribution associated with conduction in the bulk pore water and a surface conductivity associated with conduction in the electrical double layer coating the grains. The surface conductivity, the quadrature conductivity, and the normalized chargeability (defined as the difference between the in-phase conductivity at high and low frequencies) are observed to be linearly correlated to the specific surface area or the surface per volume ratio of the core samples, which can be considered as proxy of alteration. These trends are consistent with those shown by sedimentary rocks. This new data set demonstrates that the induced polarization method can be potentially used to image alteration in volcanic environments.

58 GEOSCIENCES↗

GeoNEX-SUBSETS: Geostationary Satellite Observations Over International Observing Network Sites

Satellite remote sensing is crucial for monitoring the Earth’s surface and for simulating global carbon and water cycles. Subsets of satellite data from sensors such as MODIS over established observing networks have been valuable for researchers for comparing the ground observed phenomena with satellite observations. Here, we introduce new subsets of the GeoNEX geostationary satellite datasets over locations of several ground observation networks. The NASA Earth Exchange group has been generating geostationary satellite products with our international partners and universities to cover the entire globe. In comparison to polar-orbiting satellite sensors such as MODIS, the new generation geostationary satellites observe target areas at a higher frequency (5-10 minutes), which also significantly increased the data volume. To reduce the burden of downloading and extracting geostationary time series data and provide easy access to the community, we provide subsets of GeoNEX products through our data portal [www.data.nas.nasa.gov]. The ready-to-use subset follows the same format as the MODIS fixed sites subset tools for users who are familiar with MODIS subset data and software. The selected networks include Fluxnet, AERONET, and Phenocam over the conterminous US. We demonstrate the usage of the GeoNEX fixed-site subset data and showcase thir advantages with three example studies. The first example is simulating the diurnal cycle of plant ecophysiology at Fluxnet sites. The high frequency of the GeoNEX time series allows us to run ecological models at sub-hour time steps and directly compare the simulated carbon and water fluxes with half-hourly Fluxnet data. The second example uses the geostationary data to track phenological changes. It highlights the high-frequent observations of geostationary satellites in helping mask cloud covers and capture the quick responses of vegetation to environmental changes. As such, these examples demonstrate the value of ready-to-use GeoNEX subsets data in terrestrial ecophysiology research.

GeoNEX↗

A sensitive continuum analysis method for gamma ray spectra

In this work we examine ways to improve the sensitivity of the analysis procedure for gamma ray spectra with respect to small differences in the continuum (Compton) spectra. The method developed is applied to analyze gamma ray spectra obtained from planetary mapping by the Mars Observer spacecraft launched in September 1992. Calculated Mars simulation spectra and actual thick target bombardment spectra have been taken as test cases. The principle of the method rests on the extraction of continuum information from Fourier transforms of the spectra. We study how a better estimate of the spectrum from larger regions of the Mars surface will improve the analysis for smaller regions with poorer statistics. Estimation of signal within the continuum is done in the frequency domain which enables efficient and sensitive discrimination of subtle differences between two spectra. The process is compared to other methods for the extraction of information from the continuum. Finally we explore briefly the possible uses of this technique in other applications of continuum spectra.

Thakur, Alakh N.↗

Tracking Molecular Transport Across Oil/Aqueous Interfaces: Insight into “Antagonistic” Binding in Solvent Extraction

Liquid/liquid (L/L) interfaces play a key, yet poorly understood, role in a range of complex chemical phenomena where time-evolving interfacial structures and transient supramolecular assemblies act as gatekeepers to function. Here, for this study, we employ surface-specific vibrational sum frequency generation combined with neutron and X-ray scattering methods to track the transport of dioctyl phosphoric acid (DOP) and di-(2-ethylhexyl) phosphoric acid (DEHPA) ligands used in solvent extraction at buried oil/aqueous interfaces away from equilibrium. Our results show evidence for a dynamic interfacial restructuring at low ligand concentrations in contrast to expectation. These time-varying interfaces arise from the transport of sparingly soluble interfacial ligands into the neighboring aqueous phase. These results support a proposed “antagonistic” role of ligand complexation in the aqueous phase that could serve as a holdback mechanism in kinetic liquid extractions. These findings provide new insights into interfacially controlled chemical transport at L/L interfaces and how these interfaces vary chemically, structurally, and temporally in a concentration-dependent manner and present potential avenues to design selective kinetic separations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Efficient energy extraction from a diode-pumped Q-switched Tm,Ho:YLiF4 laser

The operation of a diode-laser pumped thulium, holmium yttrium-lithium-fluoride laser (Tm,Ho:YLF) in Q-switched mode is reported. Output energies of 200 microjoules in pulses of 22 ns duration are recorded at Q-switch frequencies commensurate with an effective upper laser level lifetime of 6 ms. This lifetime is appreciably longer than that observed in other hosts permitting stored energy extraction of 64 percent, close to the projected maximum performance from these materials.

Mcguckin, B. T.↗

Beam dynamics corrections in the measurement of the anomalous precession frequency at the Muon $g-2$ experiment at Fermilab

The Muon $g-2$ experiment at Fermilab (E989) aims to measure the anomalous magnetic moment of the muon with an accuracy of 140 ppb (parts per billions). This accuracy, obtained by adding in quadrature a statistical and a systematic contribution of comparable value (100 ppb), will allow to reduce the experimental uncertainty (from the previous E821 experiment at BNL \cite{bnl}) of a factor of 4, and represents one of the most precise tests of the Standard Model (SM) theory of elementary particles. The first result on the Run-1 dataset \cite{prl} was released on April 7, 2021, showing a very good agreement with the previous result from BNL experiment, with a slightly better uncertainty. The corresponding experimental average increases the significance of the discrepancy between the measured and Standard Model prediction of 4.2$\sigma$ \cite{white_paper}.\\ \noindent The measured quantity is the muon magnetic anomaly a$_\mu$=$\frac{g_\mu-2}{2}$ where g$_\mu$ is the gyromagnetic factor of the muon. Dirac's equation predicts g$_\mu$ = 2, while radiative corrections, dominated by the QED contribution due to an exchange of a virtual photon, causes a per-mille correction on this quantity. By including all the SM contributions, a$_\mu$ is known at 370 ppb. The E989 experiment measures $a_\mu$ injecting positive muons with momentum of 3.1 GeV/$c$ polarized longitudinally in bunches (called $fills$) with an average rate of 12 Hz, in a storage ring of 14 meters diameter. Due to the parity violation in the weak muon decay, high energy positrons produced are emitted preferably in the muon's spin direction. By counting the number of positrons with energy greater then 1.7 GeV in function of the time, the frequency precession of the muon spin is measured, that together with the measurement of the magnetic field, allows to extract $a_\mu$. The positrons are detected with 24 electromagnetic calorimeters, that measure the energy and the arrival time of the positrons, each made of 54 crystals of lead fluoride (PbF$_2$) read by silicon photomultipliers (SiPM). Together with calorimeters, two tracking detectors are used to make non-destructive measurements of the muon beam characteristic by reconstructing the muon decay position extrapolating backward the decay positrons. The knowledge of the beam motion inside the ring plays a fundamental role in the analysis of $a_{\mu}$, where the measured anomalous precession frequency $\omega_a$ must be corrected for four main beam dynamics effects. A first correction is associated with the presence of an electric field responsible of the vertical focusing on the storage ring, where vertical direction is orthogonal to the orbit and horizontal direction is along the storage ring radius. Due to the oscillations in the vertical direction, the so called vertical betatron oscillations, a second correction is necessary to account for an average angle associated with the muon motion off the ideal orbit. A third correction is caused by lost muons in the ring which have a different spin phase at the injection respect to the decay ones. Finally, due to the correlation between the vertical and horizontal beam motion of the muons and the acceptance of the calorimeter, a correction (called ``phase-acceptance") arises. In Run1, due to the presence of two damaged resistors in one electrostatic quadrupole, this correction had a prominent role. The replacement of the damaged resistors before Run2 decreased this effect by one order of magnitude, and a further reduction in Run-3 was provided by an improved orbit.\\ \noindent The work of this Thesis focuses on the beam dynamics corrections on $\omega_a$. Due to the prominent role in Run-1 a special attention has been put to the phase-acceptance correction\footnote{The effect of this correction on the E821 BNL measurement of the $g-2$ has been evaluated to be within the quoted systematic error.}. Chapter \ref{ch:anomalous_magnetic_moment} introduces the anomalous magnetic moment of the muon. Chapter \ref{ch:early_experiment} describes the history of the Muon $g-2$ experiments. Chapter \ref{ch:theory} discusses the Standard Model prediction and possible new physics scenario. Chapter \ref{ch:muon_g2_experiment} describes the E989 experiment, whose experimental technique and the apparatus are discussed focusing on the improvements needed to reach the final goal on $a_\mu$ measurement. The original work of the Thesis is discussed in the last 5 chapters. Chapter \ref{ch:experiment_technique} presents the analysis technique to extract $\omega_a$, Chapter \ref{ch:beam_dynamics} describes the beam dynamics in the E989 experiment, Chapter \ref{ch:beam_dynamics_correction} discusses the beam dynamics correction to $\omega_a$, and Chapter \ref{sec:pa_corr} focuses on the phase acceptance correction. Finally Chapter \ref{ch:run23_analysis_improvements} contains the Run-2/3 improvements which are expected to allow for an increased precision ons the beam dynamics co...

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Frequency combs in optically injected terahertz ring quantum cascade lasers

Quantum cascade lasers (QCLs) have emerged as promising candidates for generating chip-scale frequency combs in mid-infrared and terahertz wavelengths. In this work, we demonstrate frequency comb formation in ring terahertz QCLs using the injection of light from a distributed feedback (DFB) laser. The DFB design frequency is chosen to match the modes of the ring cavity (near 3.3 THz), and light from the DFB is injected into the ring QCL via a bus waveguide. By controlling the power and frequency of the optical injection, we show that combs can be selectively formed and controlled in the ring cavity. Numerical modeling suggests that this comb is primarily frequency-modulated in character, with the injection serving to trigger comb formation. We also show that the ring can be used as a filter to control the output of the DFB QCL, potentially being of interest in terahertz photonic integrated circuits. Our work demonstrates that waveguide couplers are a compelling approach for injecting and extracting radiation from ring terahertz combs and offer exciting possibilities for the generation of new comb states in terahertz, such as frequency-modulated waves, solitons, and more.

47 OTHER INSTRUMENTATION↗

Advanced ion beam calorimetry for the test facility ELISE

The negative ion source test facility ELISE (Extraction from a Large Ion Source Experiment) is in operation since beginning of 2013 at the Max-Planck-Institut für Plasmaphysik (IPP) in Garching bei München. The large radio frequency driven ion source of ELISE is about 1×1 m{sup 2} in size (1/2 the ITER source) and can produce a plasma for up to 1 h. Negative ions can be extracted and accelerated by an ITER-like extraction system made of 3 grids with an area of 0.1 m{sup 2}, for 10 s every 3 minutes. A total accelerating voltage of up to 60 kV is available, i.e. a maximum ion beam power of about 1.2 MW can be produced. ELISE is equipped with several beam diagnostic tools for the evaluation of the beam characteristics. In order to evaluate the beam properties with a high level of detail, a sophisticated diagnostic calorimeter has been installed in the test facility at the end of 2013, starting operation in January 2014. The diagnostic calorimeter is split into 4 copper plates with separate water calorimetry for each of the plates. Each calorimeter plate is made of 15×15 copper blocks, which act as many separate inertial calorimeters and are attached to a copper plate with an embedded cooling circuit. The block geometry and the connection with the cooling plate are optimized to accurately measure the time-averaged power of the 10 s ion beam. The surface of the blocks is covered with a black coating that allows infrared (IR) thermography which provides a 2D profile of the beam power density. In order to calibrate the IR thermography, 48 thermocouples are installed in as many blocks, arranged in two vertical and two horizontal rows. The paper describes the beam calorimetry in ELISE, including the methods used for the IR thermography, the water calorimetry and the analytical methods for beam profile evaluation. It is shown how the maximum beam inhomogeneity amounts to 13% in average. The beam divergence derived by IR thermography ranges between 1° and 4° and correlates relatively well with the values measured by beam emission spectroscopy with up to 30% difference. It has also been observed that the beam inhomogeneity decreases with lower beam divergence.

43 PARTICLE ACCELERATORS↗

Submillimeter sources for radiometry using high power Indium Phosphide Gunn diode oscillators

A study aimed at developing high frequency millimeter wave and submillimeter wave local oscillator sources in the 60-600 GHz range was conducted. Sources involved both fundamental and harmonic-extraction type Indium Phosphide Gunn diode oscillators as well as varactor multipliers. In particular, a high power balanced-doubler using varactor diodes was developed for 166 GHz. It is capable of handling 100 mW input power, and typically produced 25 mW output power. A high frequency tripler operating at 500 GHz output frequency was also developed and cascaded with the balanced-doubler. A dual-diode InP Gunn diode combiner was used to pump this cascaded multiplier to produce on the order of 0.5 mW at 500 GHz. In addition, considerable development and characterization work on InP Gunn diode oscillators was carried out. Design data and operating characteristics were documented for a very wide range of oscillators. The reliability of InP devices was examined, and packaging techniques to enhance the performance were analyzed. A theoretical study of a new class of high power multipliers was conducted for future applications. The sources developed here find many commercial applications for radio astronomy and remote sensing.

Deo, Naresh C.↗

Multimode Directional Coupler for Utilization of Harmonic Frequencies from TWTAs

A novel waveguide multimode directional coupler (MDC) intended for the measurement and potential utilization of the second and higher order harmonic frequencies from high-power traveling wave tube amplifiers (TWTAs) has been successfully designed, fabricated, and tested. The design is based on the characteristic multiple propagation modes of the electrical and magnetic field components of electromagnetic waves in a rectangular waveguide. The purpose was to create a rugged, easily constructed, more efficient waveguide- based MDC for extraction and exploitation of the second harmonic signal from the RF output of high-power TWTs used for space communications. The application would be a satellitebased beacon source needed for Qband and V/W-band atmospheric propagation studies. The MDC could function as a CW narrow-band source or as a wideband source for study of atmospheric group delay effects on highdata- rate links. The MDC is fabricated from two sections of waveguide - a primary one for the fundamental frequency and a secondary waveguide for the second harmonic - that are joined together such that the second harmonic higher order modes are selectively coupled via precision- machined slots for propagation in the secondary waveguide. In the TWTA output waveguide port, both the fundamental and the second harmonic signals are present. These signals propagate in the output waveguide as the dominant and higher order modes, respectively. By including an appropriate mode selective waveguide directional coupler, such as the MDC presented here at the output of the TWTA, the power at the second harmonic can be sampled and amplified to the power level needed for atmospheric propagation studies. The important conclusions from the preliminary test results for the multimode directional coupler are: (1) the second harmonic (Ka-band) can be measured and effectively separated from the fundamental (Ku-band) with no coupling of the latter, (2) power losses in the fundamental frequency are negligible, and (3) the power level of the extracted second harmonic is sufficient for further amplification to power levels needed for practical applications. It was also demonstrated that third order and potentially higher order harmonics are measurable with this device. The design is frequency agnostic, and with the appropriate choice of waveguides, is easily scaled to higher frequency TWTs. The MDC has the same function but with a number of important advantages over the conventional diplexer.

Simmons, Rainee N.↗

Resolving Discrepancies in Spin-Torque Ferromagnetic Resonance Measurements: Lineshape versus Linewidth Analyses

When spin-orbit torques are measured using spin-torque ferromagnetic resonance, two alternative ways of analyzing the results to extract the torque efficiencies—lineshape analysis and analysis of the change in linewidth versus direct current—often give inconsistent results. We identify a source for these inconsistencies. We show that fits of spin-torque ferromagnetic resonance data to the standard analysis framework leave significant residuals that we identify as due to (i) current-induced excitations of a small volume of magnetic material with magnetic damping much larger than that of the bulk of the magnetic layer, which we speculate is associated with the heavy-metal–magnet interface and (ii) oscillations of the sample magnetization at the modulation frequency due to heating. Here, the dependence of the residual signals on direct current can interfere with an accurate extraction of spin-torque efficiencies by the linewidth method. We show that the discrepancies between the two types of analysis can be largely eliminated by extrapolation of the window of magnetic fields used in the linewidth fits to small values so as to minimize the influence of the residual signals.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Wireless infrastructure protection using low-cost radio frequency fingerprinting receivers

We report that low-data-rate wireless networks incorporated in critical infrastructure applications can be protected through 128-bit encryption keys and address-based access control lists. However, these bit-level credentials are vulnerable to interception, extraction and spoofing using software tools available free of charge on the Internet. Recent research has demonstrated that wireless physical layer device fingerprinting can be used to defend against replay and spoofing attacks. However, radio frequency (RF) fingerprinting typically uses expensive signal collection systems; this is because fingerprinting wireless devices with low-cost receivers has been reported to have inconsistent accuracy. In conclusion, this paper demonstrates a robust radio frequency fingerprinting process that is consistently accurate with both high-end and low-cost receivers. Indeed, the results demonstrate that low-cost software-defined radios can be used to perform accurate radio frequency fingerprinting and to identify spoofing attacks in critical IEEE 802.154-based infrastructure networks such as ZigBee.

97 MATHEMATICS AND COMPUTING↗