Search NASA⌕ Search

SEARCH · Search NASA

Results for “G FORCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Oxidation of SiC investigated by ellipsometry and Rutherford backscattering spectrometry

Oxidation of SiC was performed in Ar-O{sub 2} mixture of atmospheric pressure at 1100 deg. C and compared with that of Si. The partial pressure of O{sub 2} varied from 100 to 1000 mbar, while the oxidation time ranged from 0.5 to 45 h. The thickness of the oxide films was determined by spectroscopic ellipsometry and Rutherford backscattering spectrometry. The time and the pressure dependence of the oxidation kinetics of SiC are well described by the modified Deal-Grove model. In the diffusion-limited region, even for the faster case, the oxidation kinetics of the C-terminated face of SiC is not clearly limited by oxygen indiffusion, as for pure silicon. To interpret the ellipsometry spectra, two models of possible structure were used. In the case of the one-layer model, for layer thicknesses above 30 nm, the refractive index of the oxide layers is identical to that of thermally oxidized Si, and it increases rapidly with decreasing thickness below about 15 nm. This increase is significantly larger for C-terminated than for Si-terminated faces, and this difference can be explained by a transition layer introduced into the two-layer model. This model contains a pure SiO{sub 2} layer and a transition layer modeled by a mixture of 50 % SiO{sub 2} and 50 % SiC. The transition layer is thicker on the C-terminated surface than on the Si-terminated one. The thickness ratio of the transition layers is slightly larger than the surface roughness ratio on the two different sides determined by atomic force microscopy. The density of the oxide films, which can be determined from the backscattering and spectroscopic ellipsometry spectra, decreases with decreasing thickness below about 30 nm. For thicker films, the density of the oxide is equal to the bulk density of SiO{sub 2}.

36 MATERIALS SCIENCE↗

Novel pre-alloyed powder processing of modified alnico 8: Correlation of microstructure and magnetic properties

Progress is reviewed on development of an improved near-final bulk magnet fabrication process for alnico 8, as a non-rare earth permanent magnet with promise for sufficient energy density and coercivity for electric drive motors. This study showed that alnico bulk magnets in near-final shape can be made by simple compression molding from spherical high purity gas atomized pre-alloyed powder. Dwell time at peak sintering temperature (1250 °C) greatly affected grain size of the resulting magnet alloys. This microstructure transformation was demonstrated to be useful for gaining partially aligned magnetic properties and boosting energy product. While a route to increased coercivity was not identified by these experiments, manufacturability of bulk alnico magnet alloys in near-final shapes was demonstrated, permitting further processing and alloy modification experiments that can target higher coercivity and better control of grain anisotropy during grain growth.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Thin films of the spin ice compound Ho{sub 2}Ti{sub 2}O{sub 7}

The pyrochlore compounds Ho{sub 2}Ti{sub 2}O{sub 7} and Dy{sub 2}Ti{sub 2}O{sub 7} show an exotic form of magnetism called the spin ice state, resulting from the interplay between geometrical frustration and ferromagnetic coupling. A fascinating feature of this state is the appearance of magnetic monopoles as emergent excitations above the degenerate ground state. Over the past years, strong effort has been devoted to the investigation of these monopoles and other properties of the spin ice state in bulk crystals. Here, we report the fabrication of Ho{sub 2}Ti{sub 2}O{sub 7} thin films using pulsed laser deposition on yttria-stabilized ZrO{sub 2} substrates. We investigated the structural properties of these films by X-ray diffraction, scanning transmission electron microscopy, and atomic force microscopy, and the magnetic properties by vibrating sample magnetometry at 2 K. The films not only show a high crystalline quality, but also exhibit the hallmarks of a spin ice: a pronounced magnetic anisotropy and an intermediate plateau in the magnetization along the [111] crystal direction.

36 MATERIALS SCIENCE↗

Laser irradiation effects on the CdTe/ZnTe quantum dot structure studied by Raman and AFM spectroscopy

Micro-Raman spectroscopy has been applied to investigate the impact of laser irradiation on semiconducting CdTe/ZnTe quantum dots (QDs) structures. A reference sample (without dots) was also studied for comparison. Both samples were grown by molecular beam epitaxy technique on the p-type GaAs substrate. The Raman spectra have been recorded for different time of a laser exposure and for various laser powers. The spectra for both samples exhibit peak related to the localized longitudinal (LO) ZnTe phonon of a wavenumber equal to 210 cm{sup -1}. For the QD sample, a broad band corresponding to the LO CdTe phonon related to the QD-layer appears at a wavenumber of 160 cm{sup -1}. With increasing time of a laser beam exposure and laser power, the spectra get dominated by tellurium-related peaks appearing at wavenumbers around 120 cm{sup -1} and 140 cm{sup -1}. Simultaneously, the ZnTe surface undergoes rising damage, with the formation of Te aggregates at the pinhole edge as reveal atomic force microscopy observations. Local temperature of irradiated region has been estimated from the anti-Stokes/Stokes ratio of the Te modes intensity and it was found to be close or exceeding ZnTe melting point. Thus, the laser damage can be explained by the ablation process.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Ultra low-K shrinkage behavior when under electron beam in a scanning electron microscope

In this paper, we investigate the tendency of porous low-K dielectrics (also named Ultra Low-K, ULK) behavior to shrink when exposed to the electron beam of a scanning electron microscope. Various experimental electron beam conditions have been used for irradiating ULK thin films, and the resulting shrinkage has been measured through use of an atomic force microscope tool. We report the shrinkage to be a fast, cumulative, and dose dependent effect. Correlation of the shrinkage with incident electron beam energy loss has also been evidenced. The chemical modification of the ULK films within the interaction volume has been demonstrated, with a densification of the layer and a loss of carbon and hydrogen elements being observed.

36 MATERIALS SCIENCE↗

Magnetooptical force in the resonance field formed by elliptically polarized light waves

The dependence of the magnetooptical force on the ellipticity of the polarization of light beams is studied in terms of a one-dimensional model for closed J{sub g} {sup {yields}} J{sub e} optical transitions. A linear velocity and magnetic-field approximation is used to find analytical expressions for the magnetooptical force for a number of transitions. In the light fields formed by waves with an elliptical polarization, qualitatively new contributions are shown to appear; they have an even dependence on the detuning of the light field and do not disappear even in the case of an exact resonance. An analysis of these results demonstrates that a magnetooptical trap can stably operate at the zero detuning of the field. Numerical methods are used to investigate the nonlinear dependence of the force on the atom velocity and the magnetic field and to estimate the characteristic atom trapping rate and the number of trapped atoms.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Spatial Orientation and Balance Control Changes Induced by Altered Gravito-Inertial Force Vectors

Seventeen healthy and eight vestibular deficient subjects were exposed to an interaural centripetal acceleration of 1 G (resultant 45 deg roll tilt of 1.4 G) on a 0.8 meter radius centrifuge for a period of 90 minutes in the dark. The subjects sat with head fixed upright, except every 4 of 10 minutes when instructed to rotate their head so that their nose and eyes pointed towards a visual point switched on every 3 to 5 seconds at random places (within +/- 30 deg) in the Earth horizontal plane. Motion sickness caused some subjects to limit their head movements during significant portions of the 90 minute period, and led three normal subjects to stop the test earlier. Eye movements, including directed saccades for subjective Earth- and head-referenced planes, were recorded before, during, and immediately after centrifugation using electro-oculography. Postural stability measurements were made before and within ten minutes after centrifugation. In normal subjects, postural sway and multisegment body kinematics were gathered during an eyes-closed head movement cadence (sway-referenced support platform), and in response to translational/rotational platform perturbations. A significant increase in postural sway, segmental motion amplitude and hip frequency was observed after centrifugation. This effect was short-lived, with a recovery time of several postural test trials. There were also asymmetries in the direction of post-centrifugation center of sway and head tilt which depended on the subject's orientation during the centrifugation adaptation period (left ear or right ear out). To delineate the effect of the magnitude of the gravito-inertial vector versus its direction during the adaptive centrifugation period, we tilted eight normal subjects in the roll axis at a 45 deg angle in the dark for 90 minutes without rotational motion. Their postural responses did not change following the period of tilt. Based on verbal reports, normal subjects overestimated roll-tilt during 90 minutes of both tilt and centrifugation stimuli. Subjective estimates of head-horizontal, provided by directed saccades, revealed significant errors after approximately 30 minutes that tended to increase only in the group who underwent centrifugation. Immediately after centrifugation, subjects reported feeling tilted on average 10 degrees in the opposite direction, which was in agreement with the direction of their earth-directed saccades. In vestibular deficient (VD) subjects, postural sway was measured using a sway-referenced or earth-fixed support surface, and with or without a head movement sequence. 'Me protocol was selected for each patient during baseline testing, and corresponded to the most challenging condition in which the patient was able to maintain balance with eyes closed. Bilaterally VD subjects showed no postural decrement after centrifugation, while unilateral VD subjects had varying degrees of decrement. Unilateral VD subjects were tested twice; they underwent centrifugation both with right ear out and left ear out. Their post-centrifuation center of sway shifted at right angles depending on the centrifuge GIF orientation. Bilateral VD subjects bad shifts as well, but no consistent directional trend. VD subjects underestimated roll-tilt during centrifugation, These results suggest that orientation of the gravito-inertial vector and its magnitude arc both used by the central nervous system for calibration of multiple orientation systems. A change in the background gravito-inertial force (otolith input) can rapidly initiate postural and perceptual adaptation in several sensorimotor systems, independent of a structured visual surround.

Kaufman, Galen D.↗

Controlled Orientation of Polyconjugated Guest Molecules in Tunable Host Cavities

Linear conjugated guest molecules with high aspect ratios form inclusion compounds with guanidinium organodisulfonate (GDS) host frameworks in which organodisulfonate 'pillars' connect opposing GS sheets to generate lamellar architectures that reflect templating by the guest. Through judicious selection of pillars having adjustable lengths (l{sub S-S}, as measured by the separation between distal sulfur atoms) and guests of various lengths (l{sub g}), the framework architecture can be controlled systematically in a manner that enables regulation of the guest orientation and aggregation in the host framework. Inclusion compounds for which l{sub g}/l{sub S-S} {le} 0.9 exhibit a bilayer architecture with 1-D channels containing guests oriented parallel to the long axis of the pillar. Guests with values of l{sub g} comparable to l{sub S-S}, however, promote the formation of a brick architecture in which the guests and the pillar are arranged in a herringbone motif. Surprisingly, longer guests (l{sub g} = 1.25l{sub S-S}) favor the formation of the bilayer architecture despite their larger volume because the guests are forced to align end-to-end as single-file arrays due to the vertical constraints of the 1-D channels. Bithiophene and biphenyl guests (l{sub g} < l{sub S-S}) are exceptional, promoting bilayer structures in which turnstile rotations of the pillars afford an unusual motif in which the guests are isolated from one another. The ability to synthesize a large family of compounds based on a common supramolecular building block (the GS sheet) permits construction of a structural 'phase diagram' based on two simple molecular parameters, l{sub g} and l{sub S-S}, that can be used to sort the inclusion compounds according to their framework architectures and enable prediction of crystal structures for new host-guest combinations. The effects of these different framework architectures and packing motifs is manifested as bathochromic shifts in the absorption and emission spectra of the guests compared with their spectra in methanol solutions. This behavior is supported by ab initio TDDFT calculations that reproduce the bathochromic shifts associated with the effects of guest-guest and guest-host interactions, combined with conformational constraints imposed on the guest molecules by the rigid host framework.

10 SYNTHETIC FUELS↗

Spaceflight effects on single skeletal muscle fiber function in the rhesus monkey

The purpose of this investigation was to understand how 14 days of weightlessness alters the cellular properties of individual slow- and fast-twitch muscle fibers in the rhesus monkey. The diameter of the soleus (Sol) type I, medial gastrocnemius (MG) type I, and MG type II fibers from the vivarium controls averaged 60 +/- 1, 46 +/- 2, and 59 +/- 2 microm, respectively. Both a control 1-G capsule sit (CS) and spaceflight (SF) significantly reduced the Sol type I fiber diameter (20 and 13%, respectively) and peak force, with the latter declining from 0.48 +/- 0.01 to 0.31 +/- 0.02 (CS group) and 0.32 +/- 0.01 mN (SF group). When the peak force was expressed as kiloNewtons per square meter (kN/m(2)), only the SF group showed a significant decline. This group also showed a significant 15% drop in peak fiber stiffness that suggests that fewer cross bridges were contracting in parallel. In the MG, SF but not CS depressed the type I fiber diameter and force. Additionally, SF significantly depressed absolute (mN) and relative (kN/m(2)) force in the fast-twitch MG fibers by 30% and 28%, respectively. The Ca(2+) sensitivity of the type I fiber (Sol and MG) was significantly reduced by growth but unaltered by SF. Flight had no significant effect on the mean maximal fiber shortening velocity in any fiber type or muscle. The post-SF Sol type I fibers showed a reduced peak power and, at peak power, an elevated velocity and decreased force. In conclusion, CS and SF caused atrophy and a reduced force and power in the Sol type I fiber. However, only SF elicited atrophy and reduced force (mN) in the MG type I fiber and a decline in relative force (kN/m(2)) in the Sol type I and MG type II fibers.

Non-NASA Center↗

Quantitative comparison of two independent lateral force calibration techniques for the atomic force microscope

Two independent lateral-force calibration methods for the atomic force microscope (AFM)--the hammerhead (HH) technique and the diamagnetic lateral force calibrator (D-LFC)--are systematically compared and found to agree to within 5% or less, but with precision limited to about 15%, using four different tee-shaped HH reference probes. The limitations of each method, both of which offer independent yet feasible paths toward traceable accuracy, are discussed and investigated. We find that stiff cantilevers may produce inconsistent D-LFC values through the application of excessively high normal loads. In addition, D-LFC results vary when the method is implemented using different modes of AFM feedback control, constant height and constant force modes, where the latter is more consistent with the HH method and closer to typical experimental conditions. Specifically, for the D-LFC apparatus used here, calibration in constant height mode introduced errors up to 14 %. In constant force mode using a relatively stiff cantilever, we observed an {approx_equal} 4 % systematic error per {mu}N of applied load for loads {<=} 1 {mu}N. The issue of excessive load typically emerges for cantilevers whose flexural spring constant is large compared with the normal spring constant of the D-LFC setup (such that relatively small cantilever flexural displacements produce relatively large loads). Overall, the HH method carries a larger uncertainty, which is dominated by uncertainty in measurement of the flexural spring constant of the HH cantilever as well as in the effective length dimension of the cantilever probe. The D-LFC method relies on fewer parameters and thus has fewer uncertainties associated with it. We thus show that it is the preferred method of the two, as long as care is taken to perform the calibration in constant force mode with low applied loads.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Toward quantum Monte Carlo forces on heavier ions: Scaling properties

Quantum Monte Carlo (QMC) forces have been studied extensively in recent decades because of their importance with spectroscopic observables and geometry optimization. Here, we benchmark the accuracy and computational cost of QMC forces. The zero-variance zero-bias (ZVZB) force estimator is used in standard variational and diffusion Monte Carlo simulations with mean-field based trial wavefunctions and atomic pseudopotentials. Statistical force uncertainties are obtained with a recently developed regression technique for heavy tailed QMC data [P. Lopez Rios and G. J. Conduit, Phys. Rev. E 99, 063312 (2019)]. By considering selected atoms and dimers with elements ranging from H to Zn (1 ≤ Z eff ≤ 20), we assess the accuracy and the computational cost of ZVZB forces as the effective pseudopotential valence charge, Z eff , increases. We find that the costs of QMC energies and forces approximately follow simple power laws in Zeff. The force uncertainty grows more rapidly, leading to a best case cost scaling relationship of approximately Z e ff 6.5 ( 3 ) for diffusion Monte Carlo. We find that the accessible system size at fixed computational cost scales as Z e ff &#x2212; 2 , insensitive to model assumptions or the use of the “space warp” variance-reduction technique. Our results predict the practical cost of obtaining forces for a range of materials, such as transition metal oxides where QMC forces have yet to be applied, and underscore the importance of further developing force variance-reduction techniques, particularly for atoms with high Z eff .

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Etiological factors in space motion sickness

The human susceptibility to motion sickness during exposure to sudden-stop stimulation as a function of gravitoinertial force level is studied. It is determined that susceptibility is greatly enhanced, both with eyes-closed and eyes-open, for zero-g and 2-g conditions in parabolic flight compared with 1-g test conditions. It is argued that this change in susceptibility is related to alterations in vestibulo-occular function which result from variations in gravitoinertial force level, the altered patterns of otolithic activity resulting during variations in gravitoinertial force level, and the altered canal-otolith response synergies that result during exposure to gravitoinertial force levels greater or less than terrestrial levels. These factors are found to be related to the etiology of space motion sickness and to the alterations in performance and vestibular function that are experienced by astronauts during reentry. An explanation is presented for the decrease in susceptibility to motion sickness exhibited by the Skylab astronauts inflight and for some period postflight during exposure to cross-coupled angular accelerations.

Lackner, J. R.↗

Imaging and alignment of nanoscale 180{degree} stripe domains in ferroelectric thin films.

Nanometer-period ferroelectric 180{sup o} stripe domains are observed in epitaxial PbTiO{sub 3} films using atomic force microscopy. Stripe domains can be aligned with surface step edges or in preferred crystallographic directions. A stripe alignment map as a function of temperature and film thickness is determined using synchrotron x-ray scattering. Pinning by step edges permits control of stripe domain morphology, as demonstrated by a film grown on a vicinal surface.

43 PARTICLE ACCELERATORS↗

Evaluation of the Hydrodynamic Focusing Bioreactor (HDFB) and the Centrifugal Absorption Cartridge System (CACS) Performance Under Micro G

The Hydrodynamic Focusing Bioreactor (HDFB) technology is designed to provide a flow field with nearly uniform shear force throughout the vessel, which can provide the desired low shear force spatial environment to suspend three-dimensional cell aggregates while providing optimum mass transfer. The reactor vessel consists of a dome-shaped cell culture vessel, a viscous spinner, an access port, and a rotating base. The domed vessel face has a radius of R(o). and rotates at 0mega(o) rpm, while the internal viscous spinner has a radius of R(i) and rotates at 0mega(i) rpm. The culture vessel is completely filled with cell culture medium into which three-dimensional cellular structures are introduced. The HDFB domed vessel and spinner were driven by two independent step motors,

Gonda, Steve↗

Semiconductor Structures with a one-dimensional quantum channel and in-plane side gates fabricated by pulse force nanolithography

Quasi-one-dimensional semiconductor structures with a variable longitudinal potential profile are fabricated by pulse power nanolithography, which is carried out using an atomic force microscope. Structures are fabricated on the basis of AlGaAs/GaAs heterostructures with a deep (130 nm from the surface) twodimensional electron gas. The channel potential profile is formed with the help of sectioned in-plane gates formed on both channel sides. The electrical parameters of the structures measured at temperatures down to 1.5 K confirmed the efficiency of the applied method to fabricate insulating regions with lateral sizes of ~10 nm.

36 MATERIALS SCIENCE↗

Modeling of an Inductive Negative Ion Source for Neutral Beam Injection

We present a self-consistent two-dimensional model of a high-power inductive plasma source for negative ion production in hydrogen. The model is quasi-neutral and describes the transport and chemistry of different particle species by fluid equations including inertia and viscosity terms, coupled with the electromagnetic fields from the Maxwell equations. Results for typical conditions show a depletion of the neutral density in the plasma center and a possible reduction of wall losses due to the Lorentz force from the driving field at lower frequencies (<20 MHz)

43 PARTICLE ACCELERATORS↗

Magnetic elements for switching magnetization magnetic force microscopy tips.

Using combination of micromagnetic calculations and magnetic force microscopy (MFM) imaging we find optimal parameters for novel magnetic tips suitable for switching magnetization MFM. Switching magnetization MFM is based on two-pass scanning atomic force microscopy with reversed tip magnetization between the scans. Within the technique the sum of the scanned data with reversed tip magnetization depicts local atomic forces, while their difference maps the local magnetic forces. Here we propose the design and calculate the magnetic properties of tips suitable for this scanning probe technique. We find that for best performance the spin-polarized tips must exhibit low magnetic moment, low switching fields, and single-domain state at remanence. The switching field of such tips is calculated and optimum shape of the Permalloy elements for the tips is found. We show excellent correspondence between calculated and experimental results for Py elements.

36 MATERIALS SCIENCE↗

Plasmonic welded single walled carbon nanotubes on monolayer graphene for sensing target protein

We developed plasmonic welded single walled carbon nanotubes (SWCNTs) on monolayer graphene as a biosensor to detect target antigen molecules, fc fusion protein without any treatment to generate binder groups for linker and antibody. This plasmonic welding induces atomic networks between SWCNTs as junctions containing carboxylic groups and improves the electrical sensitivity of a SWCNTs and the graphene membrane to detect target protein. We investigated generation of the atomic networks between SWCNTs by field-emission scanning electron microscopy and atomic force microscopy after plasmonic welding process. We compared the intensity ratios of D to G peaks from the Raman spectra and electrical sheet resistance of welded SWCNTs with the results of normal SWCNTs, which decreased from 0.115 to 0.086 and from 10.5 to 4.12, respectively. Additionally, we measured the drain current via source/drain voltage after binding of the antigen to the antibody molecules. This electrical sensitivity of the welded SWCNTs was 1.55 times larger than normal SWCNTs.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗