Search NASA⌕ Search

SEARCH · Search NASA

Results for “Heat Input”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

GLIDES – Efficient Energy Storage from ORNL

The research shown in this video features the GLIDES (Ground-Level Integrated Diverse Energy Storage) project, which has been under development at Oak Ridge National Laboratory (ORNL) since 2013. GLIDES can store energy via combined inputs of electricity and heat, and deliver dispatchable electricity. Supported by ORNL’s Laboratory Director’s Research and Development (LDRD) fund, this energy storage system is low-cost, and hybridizes compressed air and pumped-hydro approaches to allow for storage of intermittent renewable energy at high efficiency. A U.S. patent application for this novel energy storage concept has been submitted, and research findings suggest it has the potential to be a flexible, low-cost, scalable, high-efficiency option for energy storage, especially useful in residential and commercial buildings.

25 ENERGY STORAGE↗

Conservation and Recycling for Radiological-Contaminated Laundry Applications - 16044

Recovery and reuse of materials exposed to radioactive environments is a critical element for those whom are involved with processing such materials. In order to minimize the disposal of radiological-contaminated Personal Protective Equipment (PPE, laundry, respirators, etc.) the need for environmentally-friendly and cost-effective technologies to provide laundering services is needed for current and future processes. A by-product of the laundry process is contaminated water. In order to reduce waste generation, we developed a radiological water filtration system custom-designed for laundry applications, which is used as both a filtration device as well as a water recycling system. The filtration process utilizes membrane filtration, suspended solids and organic filtration, ion-exchange capture, and ozonization/UV as germicidal reducers. In addition, ultrafiltration is used as a final step in order to return clean water back to the washing process system. The system was originally designed for non-radiological industrial laundry applications (hospitality, health care, correctional and governmental settings, etc). This process reduces the water consumption and discharge by up to 75% while retaining heat to minimize energy input costs. Principle components of the system include lint shakers and collection tanks with ozone injection, suspended solids filter, activated charcoal, ultraviolet lamp treatment cell, ion exchange columns, ultrafiltration filters, and final holding tank with ozone injection. Although up-front equipment costs are required, we believe that the reduction in waste generated through recycle and reuse of the water, along with avoiding premature disposal of PPE as radioactive waste, greatly outweighs up-front effort. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Deuterium Retention in NSTX with Lithium Conditioning

High (≈ 90%) deuterium retention was observed in NSTX gas balance measurements both withand without lithiumization of the carbon plasma facing components. The gas retained in ohmic discharges was measured by comparing the vessel pressure rise after a discharge to that of a gasonly pulse with the pumping valves closed. For neutral beam heated discharges the gas input and gas pumped by the NB cryopanels were tracked. The discharges were followed by outgassing of deuterium that reduced the retention. The relationship between retention and surface chemistry was explored with a new plasma-material interface probe connected to an in-vacuo surface science station that exposed four material samples to the plasma. XPS and TDS analysis showed that the binding of D atoms is fundamentally changed by lithium - in particular atoms are weakly bonded in regions near lithium atoms bound to either oxygen or the carbon matrix.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Experimental Investigation of Forced Convection and Natural Circulation Cooling of a VHTR Core under Normal Operation and Accident Scenarios

This NEUP project #15-8205 entitled “Experimental Investigation of Forced Convection and Natural Circulation Cooling of a VHTR Core under Normal Operation and Accident Scenarios”, has investigated important phenomena in the safety of Very High Temperature Reactors (VHTRs) using the experimental facilities at City College of New York (CCNY) and Kansas State University (KSU), in collaboration with the Idaho State University (ISU) and Idaho National Laboratory (INL). The main objectives of this project were to investigate the forced convection and bypass flow phenomena, natural circulation flow and heat transfer, and graphite oxidation due to air ingress which could occur in a Very High Temperature Reactor (VHTR) with a prismatic core. High pressure/high temperature experiments have been conducted to obtain data that could be used for validation of VHTR design and safety analysis codes. The focus of these experiments was on the generation of benchmark data for design and off-design heat transfer for forced and natural circulation in a VHTR core. This work has built on the previous NEUP project #11-3218 which investigated forced convection and flow laminarization phenomena in a prismatic core of a VHTR and natural circulation of a pure gas under Pressurized Conduction Cooldown (PCC) and Depressurized Conduction Cooldown (DCC) conditions. Under each Task, extensive literature reviews on natural circulation, bypass flow, air ingress and graphite oxidation phenomena were conducted. In Task 1, scaling analyses were conducted by Idaho State University followed by design and construction of experimental facilities needed to conduct both bypass flow and natural circulation experiments at CCNY. Natural circulation experiments were conducted in Task 2 to investigate the air ingress phenomena, and bypass flow phenomena in Task 3, both at CCNY. In Task 4, radiation heat transfer and graphite oxidation tests were performed at Kansas State University. The experimental data were then analyzed to obtain quantitative results on natural circulation of pure gases and gas mixtures under DCC conditions, bypass flow rates, radiation heat transfer and graphite oxidation. In addition, CFD and Direct Numerical Simulations were conducted by INL and CCNY to investigate the flow laminarization phenomenon in strongly heated gas flows. The scaling analyses have shown that the key nondimensional numbers and parameters all have acceptable distortion levels principally because the CCNY facility’s test sections have representative cooling channel dimensions and are using either helium or a scalable gas such as nitrogen at representative state conditions. The natural circulation experiments involving helium and nitrogen gas mixtures at CCNY have elucidated the effect of nitrogen (simulating air) ingress into a lower plenum on the onset of natural circulation, mass flow rates and heat transfer coefficients under different power input levels in the riser section. Also, the transport of nitrogen from the lower plenum to upper plenum due to natural circulation was quantified for the first time. Nusselt number correlations for the heat transfer coefficient under natural circulation as a function of Reynolds and Prandtl numbers was also developed. The experiments at KSU revealed that prior to the onset of natural circulationin a VHTR core. This work has built on the previous NEUP project #11-3218 which investigated forced convection and flow laminarization phenomena in a prismatic core of a VHTR and natural circulation of a pure gas under Pressurized Conduction Cooldown (PCC) and Depressurized Conduction Cooldown (DCC) conditions. Under each Task, extensive literature reviews on natural circulation, bypass flow, air ingress and graphite oxidation phenomena were conducted. In Task 1, scaling analyses were conducted by Idaho State University followed by design and construction of experimental facilities needed to conduct both bypass flow and natural circulation experiments at CCNY. Natural circulation experiments were conducted in Task 2 to investigate the air ingress phenomena, and bypass flow phenomena in Task 3, both at CCNY. In Task 4, radiation heat transfer and graphite oxidation tests were performed at Kansas State University. The experimental data were then analyzed to obtain quantitative results on natural circulation of pure gases and gas mixtures under DCC conditions, bypass flow rates, radiation heat transfer and graphite oxidation. In addition, CFD and Direct Numerical Simulations were conducted by INL and CCNY to investigate the flow laminarization phenomenon in strongly heated gas flows. The scaling analyses have shown that the key nondimensional numbers and parameters all have acceptable distortion levels principally because the CCNY facility’s test sections have representative cooling channel dimensions and are using either helium or a scalable gas such as nitrogen at representative state conditions.The natural circulation experiments involving helium and nitrogen gas mixtures at CCNY have elucidated the effect of nitrogen (simulating air) ingress into a lower plenum on the onset of natural circulation, mass flow rates and heat transfer coefficients under different power input levels in the riser section. Also, the transport of nitrogen from the lower plenum to upper plenum due to natural circulation was quantified for the first time. Nusselt number correlations for the heat transfer coefficient under natural circulation as a function of Reynolds and Prandtl numbers was also developed. The experiments at KSU revealed that prior to the onset of natural circulation(ONC), molecular diffusion plays a significant role in air-ingress, however, at higher temperatures convection currents may be influencing air ingress and in-turn ONC times. Bypass flow experiments faced difficulties in the measurement of gas velocity in the main channel due to the failure of a high temperature Hot Wire Anemometer probe, so an energy balance method was instead employed to estimate the flow distribution between the main and bypass flow channels. In the graphite oxidation experiments conducted at KSU, oxidation was found to increase the thermal diffusivity of nuclear grade graphite. This change is believed to be driven by oxidation decreasing graphite sample density rather than raising the thermal conductivity. Oxidation was also shown to greatly alter graphite emissivity. If large amounts of impurities have built up within the graphite over time and have significantly increased its effective ash content, then air ingress is likely to severely inhibit the radiative heat transfer abilities of the graphite due to the formation of low emissivity, ash layers on its surface. However, if the purity of the graphite at the time of the air ingress is still close to that of its virgin specifications, the oxidation induced roughening of the graphite’s outer surface would have the effect of slightly raising its emissivity. The flow laminarization phenomenon was investigated by INL by examining the results of Direct Numerical Simulations of previous experiments, and by CCNY conducting its own DNS simulations using DOE’s Nek5000 code

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

microbasekaplus.c1

This microbasekaplus datastream is produced by re-writed micorbaseka vap (microbasekaplus) in python under ADI framewrok, and added uncertainties for the microphysics. The original Microbase VAP was developed in 2002. The primary purpose of producing this VAP was to provide the required microphysical values for input to the Broad Band Heating Rate Profiles (BBHRP) VAP in order to generate estimations of radiative heating rates. It served the Radiatively Important Parameters Best Estimate (RIBPE) VAP in the capacity of providing baseline cloud microphysical values as input. Microbase produces cloud microphysical properties based on cloud radar measurements taken at all fixed ARM sites.

54 ENVIRONMENTAL SCIENCES↗

Thermal Runaway in Mold‐Assisted Flash Sintering

Analyzing the temperature evolution in pressureless mold‐assisted flash sintering, we found the same onset condition as in standard flash sintering: When sample's DC or AC Joule heating replaces environment's radiation heating as the dominant power input term, thermal runaway ensues. Various serial and parallel components connected to the sample, including the mold, insulation, and punches, can affect Joule heating and conduction heat loss, thus play an important role in successful mold‐assisted flash sintering.

Dong, Yanhao↗

Freeze-Tolerant Condensers

Two condensers designed for use in dissipating heat carried by working fluids feature two-phase, self-adjusting configurations such that their working lengths automatically vary to suit their input power levels and/or heat-sink temperatures. A key advantage of these condensers is that they can function even if the temperatures of their heat sinks fall below the freezing temperatures of their working fluids and the fluids freeze. The condensers can even be restarted from the frozen condition. The top part of the figure depicts the layout of the first condenser. A two-phase (liquid and vapor) condenser/vapor tube is thermally connected to a heat sink typically, a radiatively or convectively cooled metal panel. A single-phase (liquid) condensate-return tube (return artery) is also thermally connected to the heat sink. At intervals along their lengths, the condenser/vapor tube and the return artery are interconnected through porous plugs. This condenser configuration affords tolerance of freezing, variable effective thermal conductance (such that the return temperature remains nearly constant, independently of the ultimate sink temperature), and overall pressure drop smaller than it would be without the porous interconnections. An additional benefit of this configuration is that the condenser can be made to recover from the completely frozen condition either without using heaters, or else with the help of heaters much smaller than would otherwise be needed. The second condenser affords the same advantages and is based on a similar principle, but it has a different configuration that affords improved flow of working fluid, simplified construction, reduced weight, and faster recovery from a frozen condition.

Crowley, Christopher J.↗

Pyroelectric demodulating detector

A pyroelectric demodulating detector (also termed a pyroelectric demodulator) is disclosed which utilizes an electrical resistor stacked upon a pyroelectric element to demodulate an rf or microwave electrical input signal which is amplitude-modulated (AM). The pyroelectric demodulator, which can be formed as a hybrid or a monolithic device, has applications for use in AM radio receivers. Demodulation is performed by feeding the AM input signal into the resistor and converting the AM input signal into an AM heat signal which is conducted through the pyroelectric element and used to generate an electrical output signal containing AM information from the AM input signal.

47 OTHER INSTRUMENTATION↗

Comparative Analysis of HEATNETS for Geothermal Network Performance

Thermal energy networks (TENs), also known as 5th generation district energy systems, or more specifically geothermal networks when exchanging heat with geothermal boreholes, are an important technology for decarbonization. In these networks an ambient loop connects buildings and thermal sources, such as a borehole field, to exchange energy and maintain a desired loop temperature. Water-source heat pumps are used at the buildings to connect to the ambient or thermal loop to meet to the building heating and cooling loads and maintain comfort. A semi-transient, reduced-order technical model and techno-economic model, called HEATNETS, has been developed at NREL that captures the flow of energy around a TEN. In this work, a comparison of the HEATNETS technical model and a well-known coding platform used for modeling geothermal networks, TRNSYS, has been completed for a proposed geothermal network as a verification and validation process. Hourly data provided from the TRNSYS simulation included building loads, pumping power, heat pump power, temperature entering and leaving the borehole field, and mass flow rates. The hourly borehole temperatures were used to create a linear regression model utilized in HEATNETS to estimate the borehole field heat exchange. The building loads and mass flow rates were direct inputs to HEATNETS while the pumping power, heat pump power, borehole temperatures, and coefficients of performance were all simulated and calculated by HEATNETS, allowing for direct comparison of the thermal energy transfer HEATNETS considers the full process from design inputs to economic outputs and can provide modeling options for high-level initial system design and operational optimization. This study focuses on a validation of HEATNETS using results from TRNSYS. HEATNETS is not intended to replace other modeling tools, but this work demonstrates, via a comparison with an industry standard code, that HEATNETS can be a unique, high-level and rapid modeling tool for estimating the performance of a full geothermal network system.

15 GEOTHERMAL ENERGY↗

Feedback system for divertor impurity seeding based on real-time measurements of surface heat flux in the Alcator C-Mod tokamak

Mitigation of the intense heat flux to the divertor is one of the outstanding problems in fusion energy. One technique that has shown promise is impurity seeding, i.e., the injection of low-Z gaseous impurities (typically N 2 or Ne) to radiate and dissipate the power before it arrives to the divertor target plate. To this end, the Alcator C-Mod team has created a first-of-its-kind feedback system to control the injection of seed gas based on real-time surface heat flux measurements. Surface thermocouples provide real-time measurements of the surface temperature response to the plasma heat flux. The surface temperature measurements are inputted into an analog computer that “solves” the 1-D heat transport equation to deliver accurate, real-time signals of the surface heat flux. The surface heat flux signals are sent to the C-Mod digital plasma control system, which uses a proportional–integral–derivative (PID) algorithm to control the duty cycle demand to a pulse width modulated piezo valve, which in turn controls the injection of gas into the private flux region of the C-Mod divertor. This paper presents the design and implementation of this new feedback system as well as initial results using it to control divertor heat flux.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Comparative Analysis of HEATNETS for Geothermal Network Performance: Preprint

Thermal energy networks (TENs), also known as 5th generation district energy systems, or more specifically geothermal networks when exchanging heat with geothermal boreholes, are an important technology for decarbonization. In these networks an ambient loop connects buildings and thermal sources, such as a borehole field, to exchange energy and maintain a desired loop temperature. Water-source heat pumps are used at the buildings to connect to the ambient or thermal loop to meet to the building heating and cooling loads and maintain comfort. A semi-transient, reduced-order technical model and techno-economic model, called HEATNETS, has been developed at NREL that captures the flow of energy around a TEN. In this work, a comparison of the HEATNETS technical model and a well-known coding platform used for modeling geothermal networks, TRNSYS, has been completed for a proposed geothermal network as a verification process. Hourly data provided from the TRNSYS simulation included building loads, pumping power, heat pump power, temperature entering and leaving the borehole field, and mass flow rates. The hourly borehole temperatures were used to create a linear regression model utilized in HEATNETS to estimate the borehole field heat exchange. The building loads and mass flow rates were direct inputs to HEATNETS while the pumping power, heat pump power, borehole temperatures, and coefficients of performance were all simulated and calculated by HEATNETS, allowing for direct comparison of the thermal energy transfer, rather than also comparing control systems responses. HEATNETS considers the full process from design inputs to economic outputs and can provide modeling options for high-level initial system design and operational optimization. This study shows that HEATNETS, while not intended to replace other modeling tools, can be a unique modeling tool for the performance of a full geothermal network system.

15 GEOTHERMAL ENERGY↗

Development of a thermal and structural analysis procedure for cooled radial turbines

A procedure for computing the rotor temperature and stress distributions in a cooled radial turbine are considered. Existing codes for modeling the external mainstream flow and the internal cooling flow are used to compute boundary conditions for the heat transfer and stress analysis. The inviscid, quasi three dimensional code computes the external free stream velocity. The external velocity is then used in a boundary layer analysis to compute the external heat transfer coefficients. Coolant temperatures are computed by a viscous three dimensional internal flow cade for the momentum and energy equation. These boundary conditions are input to a three dimensional heat conduction code for the calculation of rotor temperatures. The rotor stress distribution may be determined for the given thermal, pressure and centrifugal loading. The procedure is applied to a cooled radial turbine which will be tested at the NASA Lewis Research Center. Representative results are given.

Kumar, Ganesh N.↗

Design and evaluation of a rotating variable conductance heat pipe system

Analysis of the Dynamics Explorer high orbiter spacecraft showed that the proposed louver system, along with existing radiator heat rejection areas on the S/C surface were insufficient to safely control the S/C's thermal excursions caused by highly varying internal power levels and solar input angles. A variable conductance heat pipe system in conjunction with a conventional radial heat pipe system was designed, built, tested, and shown to resolve this problem. The conventional pipes, radial, spinning at 10 rpm were required to carry 35 watts each after experiencing despin from 80 rpm. The VCHPs attached to the radial pipes at the S/C perimeter distributed the excess energy via a finned radiator attached around the S/C's center.

Marshburn, J. P.↗

Resonant heating - An interpretation of coronal loop data

It is shown that the resonant heating theory of Hollweg can be used to organize the coronal loop data of Golub et al. (1980). When combined with a reasonable form for the input power spectrum, the resonant heating theory is fully compatible with the loop data.

Hollweg, J. V.↗

Earth Source Heat: A Cascaded Systems Approach to DDU of Geothermal Energy on the Cornell Campus

This report documents the completion of the DOE study DE-EE0008103: Earth Source Heat: A Cascaded Systems Approach to DDU of Geothermal Energy on the Cornell Campus. This study involved a comprehensive evaluation of the potential for Earth Source Heat (ESH), Cornell’s specific application of Deep Direct Use (DDU) geothermal energy, to create a viable renewable source of thermal energy for its Ithaca, NY campus district heating system. The study included stochastic modeling that married each of two potential subsurface resources (two specific geological reservoirs) to documented campus heating operations based on hourly campus heating profiles and proposed integrated equipment controls (variable speed pumps and heat pumps). The outputs of the subsurface modeling were used as inputs for a Cornell-developed surface heat use Excel-based modeling program (the program was named “Modeled ENergy Use”, or “MEnU”). This allowed Cornell to compute realistic annual totals of extractable and useable heat for the campus, including details like heat losses, minimum summer demand, and controllable building temperature settings. The Cornell team then evaluated the costs and benefits of each modeled scenario. The primary evaluation was a standard “single bottom line” economic calculation for the Levelized Cost of Heat (LCOH). This represents the annualized cost (per unit heat) for Cornell. Additional valuations were also computed based on the benefit to the environment and to the regional economy (i.e., economic benefits external to campus). The results of this study demonstrate that if suitable reservoir flow can be attained, Earth Source Heat would be a viable technology to supply Cornell’s district heating system. This viability is based on the following criteria: (1) The modeled system produced a total useable heat output that exceeded the minimum annual campus heat load determined at the onset of the project (i.e., offsetting at least 20% of the annual campus thermal load). The output range is substantial depending on both the subsurface resource and the surface applications; at the high end, our modeled solutions produced up to ~70% of existing campus heat load with a single well pair producing 70 kg/s with integrated high-temperature heat pumps, and (2) Modeling demonstrated that multiple geothermal reservoirs could provide economically viable results when heat pumps were strategically integrated, a design that has been proven in at least one European installation already. In this context, “economically viable” means that the LCOH for the project is less than the regional commercial price of heat that would be generated using natural gas (the most common and cheapest fossil alternative in our area). Based on a single-bottom-line (LCOH) valuation, our results show that economic success is likely for any reservoir deeper than about 2.25 km where a sufficient permeability exists (or can be created with stimulation or similar engineering enhancement) and reasonable production temperatures sustained over time. The LCOH values of $\$ 4.77$ to $\$ 6.46$ per MMBtu are all lower than the comparable cost of providing heat energy with a natural gas boiler for a facility in the Northeast U.S. that obtains natural gas at commercial rates (Commercial heat costs would include at least $\$ 9.41$ in fuel costs, representing total boiler/transfer efficiency of 85% using gas at $\$ 8.00$ per MMBtu; LCOH would be higher if capital equipment and other operating costs were included). In addition to LCOH, Cornell’s scope also included evaluation of the Environmental value and Regional Economic value of each scenario. When considering the environmental and regional economic value of such a project, the overall “triple bottom line” cost (i.e., the LCOH less the LCOH ENV and LCOH REG values) is even lower and in some cases negative; i.e., in some cases a project achieving the listed performance would have higher value to the environment and to the regional economy than the total project costs over the 30-year project timeframe.

15 GEOTHERMAL ENERGY↗

Dynamics of heat-pipe reactors

A split-core heat pipe reactor, fueled with either U(233)C or U(235)C in a tungsten cermet and cooled by 7-Li-W heat pipes, was examined for the effects of the heat pipes on reactor while trying to safely absorb large reactivity inputs through inherent shutdown mechanisms. Limits on ramp reactivity inputs due to fuel melting temperature and heat pipe wall heat flux were mapped for the reactor in both startup and at-power operating modes.

Niederauer, G. F.↗

1-D Transient Thermal Modeling of an Ablative Material (MCC-1) Exposed to a Simulated Convective Titan 4 Launch Environment

The purpose of the work is to demonstrate that the flat test panel substrate temperatures are consistent with analysis predictions for MCC-1 applied to a aluminum substrate. The testing was performed in an aerothermal facility on samples of three different thicknesses of MCC-1 on an aluminum substrate. The results of the test were compared with a Transient Thermal model. The key assumptions of the Transient Thermal model were: (1) a one-dimensional heat transfer; (2) a constant ablation recession rate (determined from pre and post-test measurements); (3) ablation temperature of 540 degrees F; (4) Char left behind the ablation front; and (5) temperature jump correction for incident heat transfer coefficient. Two methods were used to model the heating of bare MCC-1: (1) Directly input surface temperature as a function of time; and (2) Aerothermal heating using calibration plate data and subtracting the radiation losses to tunnel walls. The results are presented as graphs. This article is presented in Viewgraph format.

Reinarts, Thomas R.↗