Search NASA⌕ Search

SEARCH · Search NASA

Results for “Hourly Load”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Opportunities for Demand Response in California Agricultural Irrigation: A Scoping Study

California agricultural irrigation consumes more than ten billion kilowatt hours of electricity annually and has significant potential for contributing to a reduction of stress on the grid through demand response, permanent load shifting, and energy efficiency measures. To understand this potential, a scoping study was initiated for the purpose of determining the associated opportunities, potential, and adoption challenges in California agricultural irrigation. The primary research for this study was conducted in two ways. First, data was gathered and parsed from published sources that shed light on where the best opportunities for load shifting and demand response lie within the agricultural irrigation sector. Secondly, a small limited survey was conducted as informal face-to-face interviews with several different California growers to get an idea of their ability and willingness to participate in permanent load shifting and/or demand response programs. Analysis of the data obtained from published sources and the survey reveal demand response and permanent load shifting opportunities by growing region, irrigation source, irrigation method, grower size, and utility coverage. The study examines some solutions for demand response and permanent load shifting in agricultural irrigation, which include adequate irrigation system capacity, automatic controls, variable frequency drives, and the contribution from energy efficiency measures. The study further examines the potential and challenges for grower acceptance of demand response and permanent load shifting in California agricultural irrigation. As part of the examination, the study considers to what extent permanent load shifting, which is already somewhat accepted within the agricultural sector, mitigates the need or benefit of demand response for agricultural irrigation. Recommendations for further study include studies on how to gain grower acceptance of demand response as well as other related studies such as conducting a more comprehensive survey of California growers.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Premium quality 5A1-2.5 Sn ELI titanium production

Preliminary design and reliability analysis conducted on the turbopump for the NERVA 75,000 full flow cycle engine, indicated that the turbopump bearings were the most critical turbopump parts in meeting the 10 hour life at the required turbopump reliability of .99978. The analysis revealed that significant reductions (approximately a factor of 3.25) in bearing loads would be achieved by fabricating the rotating parts from titanium in lieu of A286 or 718. This is basically due to the difference in density of the materials and the resulting mass effect on the location of the first and second stick mode critical speeds. For the selected rotor configuration, the lighter material has a first critical speed at approximately 36,000 rpm, while that of the heavier material has a first critical at approximately 27,000 rpm. As the operating range of the turbopump is from 0 to 30,000 rpm, the heavier material would have a stick mode critical in the operating range.

Dessau, P. P.↗

Estimated lift-drag ratios at supersonic speed

Recent developments in supersonic flow theory are applied to obtain estimates of the lift-drag ratios that may be achieved by aircraft employing sweptback wings. Lift-drag ratios greater than 10 to 1 can be maintained up to a Mach number of 1.4by the use of large angles of sweep and high aspect ratios. As the speed increases in the supersonic range the attainable lift-drag ratios decrease and the gain due to sweepback also appears to diminish. An efficient configuration for M = 1.4 would require about 60 deg sweepback, an aspect ratio of 4 and a wing loading of one third the atmospheric pressure. For a wing loading of 50 pounds per square foot the cruising altitude would be 60,000 feet and the indicated airspeed 290 miles per hour.

Jones, R. T.↗

Mental workload measurement: Event-related potentials and ratings of workload and fatigue

Event-related potentials were elicited when a digitized word representing a pilot's call-sign was presented. This auditory probe was presented during 27 workload conditions in a 3x3x3 design where the following variables were manipulated: short-term load, tracking task difficulty, and time-on-task. Ratings of workload and fatigue were obtained between each trial of a 2.5-hour test. The data of each subject were analyzed individually to determine whether significant correlations existed between subjective ratings and ERP component measures. Results indicated that a significant number of subjects had positive correlations between: (1) ratings of workload and P300 amplitude, (2) ratings of workload and N400 amplitude, and (3) ratings of fatigue and P300 amplitude. These data are the first to show correlations between ratings of workload or fatigue and ERP components thereby reinforcing their validity as measures of mental workload and fatigue.

Biferno, M. A.↗

Development of Low Global Warming Potential Refrigerant Solutions for Commercial Refrigeration Systems using a Life Cycle Climate Performance Design Tool

Commercial refrigeration systems are known to be prone to high leak rates and to consume large amounts of electricity. As such, direct emissions related to refrigerant leakage and indirect emissions resulting from primary energy consumption contribute greatly to their Life Cycle Climate Performance (LCCP). In this paper, an LCCP design tool is used to evaluate the performance of a typical commercial refrigeration system with alternative refrigerants and minor system modifications to provide lower Global Warming Potential (GWP) refrigerant solutions with improved LCCP compared to baseline systems. The LCCP design tool accounts for system performance, ambient temperature, and system load; system performance is evaluated using a validated vapor compression system simulation tool while ambient temperature and system load are devised from a widely used building energy modeling tool (EnergyPlus). The LCCP design tool also accounts for the change in hourly electricity emission rate to yield an accurate prediction of indirect emissions. The analysis shows that conventional commercial refrigeration system life cycle emissions are largely due to direct emissions associated with refrigerant leaks and that system efficiency plays a smaller role in the LCCP. However, as a transition occurs to low GWP refrigerants, the indirect emissions become more relevant. Low GWP refrigerants may not be suitable for drop-in replacements in conventional commercial refrigeration systems; however some mixtures may be introduced as transitional drop-in replacements. These transitional refrigerants have a significantly lower GWP than baseline refrigerants and as such, improved LCCP. The paper concludes with a brief discussion on the tradeoffs between refrigerant GWP, efficiency and capacity.

GWP↗

Hybrid Power Plants for Energy Resilience: A Case Study

As renewable energy technologies are increasingly adopted, they pose an opportunity to improve the sustainability and resilience of distributed grids, especially when their design and operation is coordinated as a hybrid power plant. When included in hybrid power plants, distributed wind turbines in particular have the potential to enhance the resilience of distributed grids in areas with good wind resource, due to their ability to provide more consistent generation and ancillary services as compared to photo-voltaic (PV) solar panels. Despite this benefit, U.S. distributed wind adoption is lower than other comparable renewable energy technologies. In this study, we seek to demonstrate how hybrid power plants that include distributed wind turbines can contribute to distribution grid resilience by meeting loads (especially critical loads) more consistently, increasing reserve capacity, and providing value to customers during outages. To demonstrate these contributions, we integrate three separate frameworks and apply them to a case study in a rural electric cooperative in Iowa. Through this case study, we simulate and compare hybrid power plant design and operation during two hazard events: a tornado that causes a 48-hour distribution outage and a winter weather event that causes a 6-hour generation outage. The inclusion of a hybrid power plant that leverages 1) increased battery duration and 2) advanced forecasting and dispatch strategies that reserve capacity leading up to a hazard event best reduce lost loads as well as diesel consumption that would otherwise be used to meet those loads during short- and long-duration hazard events. Depending on the hybrid power plant capacity and operation, we find that the outage mitigation value of a hybrid power plant (measured in value to customers to avoid an outage and avoided lost revenues for the utility) is significant in both hazard events; adding wind, solar, and battery assets to the existing system adds about $50-$100M in avoided lost load and at least $4-$8k in utility value in the tornado hazard event, and $570k-$2.2M in avoided lost load and at least $220-$650 in utility value in the winter hazard scenario. In both the tornado and winter hazard scenarios, optimizing the operation of the hybrid system for resilience can lend similar value as increasing battery duration by 5 MWh for the lower capacity systems considered.

17 WIND ENERGY↗

Status and Trends in the U.S. Voluntary Power Market: 2023 Data

Voluntary green power, for this report, refers to renewable energy procurement by retail electricity customers above what is otherwise provided by load-serving entities. This report is part of an annual series of reports synthesizing trends in the U.S. voluntary green power market. In 2023, about 9.7 million retail electricity customers procured about 319 million megawatt-hours (MWh) of voluntary green power (Figure ES-1), representing a 17% increase over sales in 2022. Estimated voluntary green power market sales represented about 44% of non-hydropower renewable energy sales and about 8% of all U.S. retail electricity sales in 2023. Most of the remainder of U.S. renewable energy sales reflects renewable energy procured by load-serving entities to comply with state renewable energy mandates, also known as compliance-based procurement. The U.S. voluntary green power market is undergoing a clear shift toward long-term contracts, driven primarily by increasingly ambitious corporate renewable energy procurement targets.

2023↗

A Privacy Preserving Model-Free Optimization and Control Framework for Demand Response from Residential Thermal Loads

We consider the problem of optimizing the cost of procuring electricity for a large collection of homes managed by a load serving entity, by pre-cooling or pre-heating the thermal inertial loads in the homes to avoid procuring power during periods of peak electricity pricing. We would like to accomplish this objective in a completely privacy-preserving and model-free manner, that is, without direct access to the state variables (temperatures or power consumption) or the dynamical models (thermal characteristics) of individual homes, while guaranteeing personal comfort constraints of the consumers. We propose a two-stage optimization and control framework to address this problem. In the first stage, we use a long short-term memory (LSTM) network to predict hourly electricity prices, based on historical pricing data and weather forecasts. Given the hourly price forecast and thermal models of the homes, the problem of designing an optimal power consumption trajectory that minimizes the total electricity procurement cost for the collection of thermal loads can be formulated as a large-scale integer program (with millions of variables) due to the on-off cyclical dynamics of such loads. We provide a simple heuristic relaxation to make this large-scale optimization problem model-free and computationally tractable. In the second stage, we translate the results of this optimization problem into distributed open-loop control laws that can be implemented at individual homes without measuring or estimating their state variables, while simultaneously ensuring consumer comfort constraints. We demonstrate the performance of this approach on a large-scale test case comprising of 500 homes in the Houston area and benchmark its performance against a direct model-based optimization and control solution.

Sivaranjani, S.↗

Comparative study of the cooling energy performance of variable refrigerant flow systems and variable air volume systems in office buildings

Variable air volume (VAV) and variable refrigerant flow (VRF) systems are widely used in office buildings. This study investigated VAV and VRF systems in five typical office buildings in China, and compared their cooling energy use. Site survey and field measurements were conducted to collect the data of building characteristics and operation. Measured cooling electricity use was collected from sub-metering in the five buildings. The sub-metering data normalized by climate and operating hours indicated that the cooling energy consumed by VRF systems was up to 70% lower than that consumed by VAV systems. This was mainly because of the different operation modes of both system types that led to significantly fewer operating hours for the VRF systems. Building simulations were used to quantify the impact of operation modes of VRF and VAV systems on cooling loads. A prototype office building in China was used as the model. The simulation results showed that the VRF operation mode required much lower cooling load when compared to the VAV operation mode. For example, the cooling loads decreased by 42% in Hong Kong and 53% in Qingdao. Key findings include the following: the VRF systems operated in the part-time-part-space mode enabling occupants to turn on the air-conditioning only when needed and when the spaces were occupied. However, the VAV systems operated in the full-time-full-space mode limiting occupants’ control of operation. These findings provide insights into VRF systems operation and controls as well as their energy performance, which could help guide HVAC designers on system selection and building operators or facility managers on system operations to achieve low- or zero-net energy buildings.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Stochastic scheduling for commercial building cooling systems: considering uncertainty in zone temperature prediction

Here, this paper presents the first attempt to address the uncertainty in zone temperature prediction with stochastic optimization. The uncertain zone temperature is a process uncertainty and has not been considered in the existing stochastic optimization for building control. To fill this gap, we proposed a novel formulation of stochastic optimization to handle process uncertainty in building control. Specifically, we first examined the accuracy of a typical linear model for predicting zone temperature. We then formulated the scheduling of the building cooling system as a stochastic optimization problem over a 24-hour look-ahead period to minimize the electricity cost of the studied building cooling system. After that, we applied the proposed stochastic load scheduling (SLS) to a direct expansion (DX) cooling system that serves a medium office building. Through simulation with a detailed building energy simulation software, EnergyPlus, we evaluated the operational cost and the thermal comfort compared with a deterministic load scheduling. The operation cost of scheduling was found to vary with the level of zone temperature prediction uncertainty. The proposed SLS can mitigate the impacts of uncertain zone temperature predictions on both operational cost and thermal comfort. The evaluation results indicate that the proposed SLS works better when the uncertainty level is more significant.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Switch Opening and Exchange Method for Stochastic Distribution Network Reconfiguration

The purpose of distribution network reconfiguration (DNR) is to determine the optimal topology of an electricity distribution network, which is an efficient measure to reduce network power losses. Electricity load demand and photovoltaic (PV) output are uncertain and vary with time of day, and will affect the optimal network topology. Single-hour deterministic DNR is incapable of handling this uncertainty and variability. Therefore, this paper proposes to solve a multi-hour stochastic DNR (SDNR). Existing solution methods for DNR are either inaccurate or excessively time-consuming, and are therefore incapable of solving multi-hour SDNRs for large distribution networks. In this regard, a switch opening and exchange (SOE) method is proposed. Starting from a looped network with all switches closed, the SOE consists of three steps. The first step is to sequentially open the switches until all of the loops are opened. The second and third steps modify the status of branches obtained in the first step to obtain better radial topologies. Five test systems are used to validate the accuracy and fast solution speed of the SOE and the superiority of multi-hour SDNR over single-hour deterministic DNR.

distribution network reconfiguration↗

Energy Storage for DC Fast Chargers Development and Demonstration of Operating Protocols for 20-kWh and 200-kWh Field Sites

Many of the currently available and future electric vehicles can be fast charged, and, typically, at least 50% of the battery capacity can be returned in 15 to 20 minutes. This charge rate requires a power of at least 50 kilowatts, which can be expensive in terms of both infrastructure and electric utility demand charges. One potential way of minimizing this cost is to charge the electric vehicle with combined battery and grid power, thereby reducing the peak load on the grid. Many sizes and configurations are possible for such a battery. This study examines two possibilities: (1) a 20-kilowatt hour (kWh) battery energy storage (BES) system and (2) a 200-kWh BES system, as well as developing standard test procedures for assessing the suitability of battery technologies for use in such systems.

25 ENERGY STORAGE↗

Analysis of 12 AH aerospace nickel-cadmium cells from the design variable program

The Design Variable Program of NASA/GSFC provided a systematic approach to evaluate the performance of 12 Ampere-Hour Nickel-Cadmium cells of different designs. Design Variables tested in this program included teflonated negative plates, silver treated negative plates, lightly loaded negative plates, positive plates with no cadmium treatment, plate design of 1968 utilizing old and new processing techniques and electrochemically impregnated positive plates. These cells were life cycled in a Low-Earth Orbit (LEO) regime for 3 to 4 years. Representative cells taken from the Design Variable Program were examined via chemical, electrochemical and surface analyses. The results indicate the following: (1) positive swelling and carbonate content in the electrolyte increase as a function of number of cycles; (2) electrolyte distribution follows a general order NEG greater than POS greater than SEP; (3) control and No PQ groups outperformed the rest of the groups; and (4) the polyproylene group exhibited heavy cadmium migration and poor performance.

Vasanth, Kunigahalli L.↗

Tensile properties of AZ11A-0 magnesium-alloy sheet under rapid-heating and constant temperature

Specimens of AZ31A-0 magnesium alloy sheet were heated to rupture at nominal rates of 0.2 F to 100 F per second under constant tensile load conditions. The data are presented and compared with the results of conventional tensile stress-strain tests at elevated temperatures after 1.2-hour exposure. A temperature-rate parameter was used to construct master curves from which stresses and temperatures for yield and rupture can be predicted under rapid-heating conditions. A comparison of the elevated-temperature tensile properties of AZ31A-0 and HK31XA-H24 magnesium-alloy sheet under both constant-temperature and rapid-heating conditions is included.

MATERIALS, PROPERTIES - THERMAL↗

Thermal/Mechanical Durability of Polymer-Matrix Composites in Cryogenic Environments

In order to increase the reliability of the next generation of space transportation systems, the mechanical behavior of polymeric-matrix composite (PMC) materials at cryogenic temperatures must be investigated. This paper presents experimental data on the residual mechanical properties of a carbon fiber polymeric composite, IM7/PETI-5 as a function of temperature and aging. Tension modulus and strength were measured at room temperature, -196 C, and -269 C on five different specimens ply lay-ups. Specimens were preconditioned with one set of coupons being isothermally aged for 576 hours at -184 C, in an unloaded state. Another set of corresponding coupons were mounted in constant strain fixtures such that a constant uniaxial strain was applied to the specimens for 576 hours at -184 C. A third set was mechanically cycled in tension at -184 C. The measured properties indicated that temperature, aging, and loading mode can all have significant influence on performance. Moreover, this influence is a strong function of laminate stacking sequence. Thermal-stress calculations based on lamination theory predicted that the transverse tensile ply stresses could be quite high for cryogenic test temperatures. Microscopic examination of the surface morphology showed evidence of degradation along the exposed edges of the material because of aging at cryogenic temperatures. ________________

Gates, Thomas S.↗

Thermal Vacuum Testing of a Multi-Evaporator Miniature Loop Heat Pipe

Under NASA's New Millennium Program Space Technology 8 Project, four experiments are being developed for future small system applications requiring low mass, low power, and compactness. GSFC is responsible for developing the Thermal Loop experiment, which is an advanced thermal control system consisting of a miniature loop heat pipe (MLHP) with multiple evaporators and condensers. The objective is to validate the operation of an MLHP, including reliable start-ups, steady operation, heat load sharing, and tight temperature control over the range of 273K to 308K. An MLHP Breadboard has been built and tested for 1200 hours under the laboratory environment and 500 hours in a thermal vacuum chamber. Results of the TV tests are presented here.

Ku, Jentung↗

SMART Rotor Wind Tunnel Test Report

The Boeing Company, Mesa Arizona, has been developing smart material actuated rotor technology (SMART) under in-house, DARPA (Defense Advanced Research Projects Agency), NASA and Army funding. A whirl tower test of the SMART active flap rotor system was successfully conducted at the remote test facility (RTF) in Mesa, Arizona, in 2003. Under DARPA and NASA funding, the SMART rotor system was tested in the NASA Ames National Full Scale Aerodynamic Complex (NFAC) 40- by 80-Foot Wind Tunnel in 2008. The DARPA program objectives were to demonstrate the active flap impact on rotor acoustics in forward flight and establish a validation database for noise prediction tools. Under NASA funding, additional wind tunnel tests were conducted, with the objective to demonstrate and quantify vibration, noise, and performance improvements.Wind tunnel testing was successfully and safely concluded, meeting all high priority objectives. The authority, effectiveness, and reliability of the flap actuation system were demonstrated in 65 hours of testing at up to 155 knots and 7,700 pound thrust. Validation data was successfully acquired for four test conditions; blade loads were too high for the high speed condition. The effectiveness of the flap for noise and vibration control was demonstrated conclusively, with results showing significant reductions in BVI (Blade-Vortex Interaction) and in-plane noise as well as vibratory hub loads. The impact of the flap on control power and rotor smoothing was also demonstrated. Data evaluating any benefits in aerodynamic performance and impact on flight controls were acquired, but will need more detailed evaluation. Both open loop control and closed loop feedback control, using continuous time and higher harmonic controllers, were applied.The purpose of the Test Report is to provide a comprehensive document that describes the preparation for and conduct of the wind tunnel test and summarizes the processing and evaluation of wind tunnel test data for the DARPA and the NASA portion of the test. An overview of the wind tunnel test and results can be found in Reference 1. Details on the testing and results for BVI noise, in-plane noise, and vibrations can be found in References 2-4, respectively. These references are four papers, presented at the American Helicopter Society Annual Forum in 2009. A brief description of the delivered electronic data is provided in Reference 5.

Rotor↗

A Machine Learning-Assisted Framework to Control Thermally Anisotropic Building Envelopes in Residential Buildings

To curb the energy consumption of buildings and their related CO2 emissions, Oak Ridge National Laboratory (ORNL) has developed the thermally anisotropic building envelope (TABE) —a multi-layer design comprising insulation materials and metal foils connected to thermal loops. In this study, a machine learning-assisted framework was developed to control the TABE in residential buildings to reduce the computation load for future optimal rule-based control and application. First, a 2D finite element model was established in COMSOL to calculate the hourly heat flux through exterior walls installed with the TABE. Then, TABE wall heat fluxes were simulated for various given indoor and outdoor boundary conditions, as well as thermal loops fluid temperatures and flow rates. Since the finite element simulations are computationally expensive, an artificial neural network (ANN) was then trained to use as a proxy of the finite element (COMSOL) modeling. Finally, the trained ANN model was coupled with the EnergyPlus model to predict the energy consumption of a US Department of Energy prototype single-family house installed with the TABE. An optimal simple rule-based control was determined from predefined rules for a case study. The results demonstrate that the developed machine learning–assisted framework can reduce 99.9% of the computation time while efficiently managing residential building energy for installed TABE walls.

Shen, Zhenglai↗