Search NASA⌕ Search

SEARCH · Search NASA

Results for “IMPLANTATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

How Small Can We Go? Evaluating Survival, Tag Retention, and Growth of Juvenile Chinook Salmon Implanted with a New Acoustic Microtag

Abstract Recently, an acoustic microtag, called the Eel–Lamprey Acoustic Tag (ELAT), was developed for use in juvenile American Eel Anguilla rostrata and Pacific Lamprey Entosphenus tridentatus. The ELAT (12.0 × 2.0 mm; 0.088 g in air) has the potential to be used to study other small-bodied fishes. In this pilot study, juvenile Chinook Salmon Oncorhynchus tshawytscha 52–99 mm fork length (FL) were surgically implanted with an ELAT (n = 99) or remained untagged (control; n = 101). Fish were held for 30 d to evaluate survival, tag retention, and growth. Survival did not differ significantly between control (n = 98 or 97.0%) and tagged fish (n = 95 or 95.9%). Logistic regression analysis suggested that survival was influenced by initial FL and tag burden. Mortalities only occurred in tagged fish with initial FLs of ≤65 mm (FL range = 57–65 mm; tag burdens = 3.8–5.9%). However, a tagged fish with an initial FL of 62 mm or an initial tag burden of 4.1% (FL range = 58–64 mm) was predicted to have a 90% chance of survival, and the smallest fish that survived the study was 54 mm FL (1.8 g; tag burden = 4.9%). Tag retention was high (99%), with only one fish expelling an ELAT during the study. Control fish grew slightly larger than the tagged individuals, but differences in final pooled FLs and weight gains were not significant. Our results demonstrate the successful surgical implantation of the ELAT into Chinook Salmon as small as 54 mm FL (1.8 g).

59 BASIC BIOLOGICAL SCIENCES↗

FDG-MicroPET and Diffusion-Weighted MR Image Evaluation of Early Changes After Radiofrequency Ablation in Implanted VX2 Tumors in Rabbits

The objective of this study was to evaluate the early changes after radiofrequency ablation (RFA) in VX2 rabbit tumors implanted into the back muscles by diffusion-weighted magnetic resonance (MR) imaging and {sup 18}F-2-fluoro-2-deoxy-D-glucose positron emission tomography ({sup 18}F-FDG PET). Percutaneous CT-guided RFA was conducted in seven rabbits with implanted VX2 tumors. VX2 tumors on the other side were untreated and served as the control. MR imaging was performed with a clinical 1.5-T instrument 2 days after RFA, and FDG-PET, using a high-resolution PET scanner for small animals, was obtained 3 days after the procedure. The mean apparent diffusion coefficient (ADC) values and radioactivity count of untreated and ablated tumors were calculated. Untreated VX2 tumors showed hyperintensity on T1-, T2-, and diffusion-weighted MR images, ring-enhanced on contrast-enhanced T1-weighted imaging, and ring-shaped FDG accumulation on FDG-PET. Ablated VX2 tumors showed slight hyperintensity on T1-, T2-, and diffusion-weighed images, slight enhancement on contrast-enhanced T1-weighted images, and low accumulation on FDG-PET. The ADC value of ablated VX2 tumors (1.52 {+-} 0.24 x 10{sup -3} mm{sup 2}/s) was significantly higher than that of untreated tumors (1.09 {+-} 0.12 x 10{sup -3}; p < 0.05). The tumor/muscle ratio of ablated tumors (0.5 {+-} 0.3) was significantly lower than that of untreated tumors (11.6 {+-} 3.2; p < 0.05). Histopathological examination confirmed the lack of viable tumor cells in the ablated lesions. The results indicate that both ADC value and FDG-PET are potentially useful markers for monitoring the early effects of RFA.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Combined Arterial Infusion and Stent Implantation Compared with Metal Stent Alone in Treatment of Malignant Gastroduodenal Obstruction

Many patients with malignant gastroduodenal obstruction have an unresectable primary lesion and distant metastases, which may prompt palliative management to allow the patient to eat and to improve the quality of life. Intraluminal metallic stent implantation (MSI) under fluoroscopic guidance has been reported to be an effective option for symptomatic relief in these patients, with a good safety record. An alternative, dual interventional therapy (DIT), has been used during the last decade, in which prosthesis insertion is followed by intra-arterial chemotherapy via the tumor-feeding arteries. The aim of this study was to compare success rates, complication rates, and survival time between MSI and DIT in patients who presented with gastroduodenal obstruction from advanced upper gastrointestinal tract cancer. All consecutive patients with malignant gastroduodenal obstruction seen at our center between October 2002 and August 2007 were retrospectively studied. Patients were treated palliatively by either MSI or DIT by the patient's or the next of kin's decision. Outcomes included technical and clinical success, complication rates, and survival. Of the 164 patients with malignant gastric and duodenal outlet obstructions, 80 (49%) underwent stent insertion as the primary therapy, while the remaining 84 (51%) received DIT. Clinical characteristics were similar between the two groups. In the MSI cohort initial stent implantation was successful in 73 patients (91%), two stents were used in 5 patients, and delayed additional stent insertion for stent obstruction related to tumor overgrowth was required in 3 patients during follow-up. In the DIT cohort the technical success rate was 94%, 3 patients required two stents, and stent obstruction occurred in 2 patients after initial stent placement. Early postprocedural clinical success, indicated by average dysphagia score, improved significantly in both groups: MSI group, from 4.56 to 1.51 (P < 0.01); and DIT group, from 4.38 to 1.48 (p < 0.01). There were no short-term complications. Late complications including hematemesis (n = 3), migration (n = 12), and stent occlusion due to tumor overgrowth (n = 5) were evenly distributed between the groups. In the DIT group chemotherapy-induced neutropenia and transient renal dysfunction were detected in six patients, which improved after symptomatic management. Mean survival time after the procedure was 5.9 and 11.1 months for MSI and DIT, respectively (P < 0.001). In conclusion, both MSI and DIT offer effective palliation for malignant gastroduodenal obstruction, but DIT appears to offer superior survival over MSI alone. Ideally, a prospective randomized trial comparing these two techniques should be carried out to validate this result.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Central Vein Dilatation Prior to Concomitant Port Implantation

Implantation of subcutaneous port systems is routinely performed in patients requiring repeated long-term infusion therapy. Ultrasound- and fluoroscopy-guided implantation under local anesthesia is broadly established in interventional radiology and has decreased the rate of complications compared to the surgical approach. In addition, interventional radiology offers the unique possibility of simultaneous management of venous occlusion. We present a technique for recanalization of central venous occlusion and angioplasty combined with port placement in a single intervention which we performed in two patients. Surgical port placement was impossible owing to occlusion of the superior vena cava following placement of a cardiac pacemaker and occlusion of multiple central veins due to paraneoplastic coagulopathy, respectively. In both cases the affected vessel segments were dilated with balloon catheters and the port systems were placed thereafter. After successful dilatation, the venous access was secured with a 25-cm-long, 8-Fr introducer sheath, a subcutaneous pocket prepared, and the port catheter tunneled to the venipuncture site. The port catheter was introduced through the sheath with the proximal end connected to a 5-Fr catheter. This catheter was pulled through the tunnel in order to preserve the tunnel and, at the same time, allow safe removal of the long sheath over the wire. The port system functioned well in both cases. The combination of recanalization and port placement in a single intervention is a straightforward alternative for patients with central venous occlusion that can only be offered by interventional radiology.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Subclavian Vein Versus Arm Vein for Totally Implantable Central Venous Port for Patients with Head and Neck Cancer: A Retrospective Comparative Analysis

Purpose: This study was designed to compare central venous ports (CVP) from two different routes of venous access-the subclavian vein and arm vein-in terms of safety for patients with head and neck cancer (HNC). Methods: Patients with HNC who underwent image-guided implantations of CVPs were retrospectively evaluated. All CVPs were implanted under local anesthesia. Primary outcome measurements were rates and types of adverse events (AEs). Secondary outcomes included technical success and rate and reason of CVP removal. Results: A total of 162 patients (subclavian port group, 47; arm port group, 115) were included in this study. Technical success was achieved in all patients. The median follow-up period was 94 (range, 1-891) days. Two patients in the subclavian port group experienced periprocedural complications. Postprocedural AEs were observed in 8.5 and 22.6% of the subclavian port and arm port group patients, respectively (P = 0.044). Phlebitis and system occlusions were observed only in the arm port group. The rate of infection was not significantly different between the two groups. The CVP was removed in 34 and 39.1% of the subclavian port and arm port patients, respectively. Conclusions: Both subclavian and arm CVPs are feasible in patients with HNC. AEs were more frequent in the arm port group; thus, the arm port is not recommended as the first choice for patients with HNC. However, further experience is needed to improve the placement technique and the maintenance of CVPs and a prospective analysis is warranted.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Endovascular Repair of a Perforation of the Vena Caval Wall Caused by the Retrieval of a Gunther Tulip Filter After Long-Term Implantation

Symptomatic penetration of the inferior vena cava (IVC) wall reportedly occurs in 0.3% of patients in whom a filter has been implanted, and it causes injury to the adjacent structures (Bogue et al. in Pediatr Radiol 39(10):1110-1113, 1; Brzezinski et al. in Burns 32(5):640-643, 2). We succeeded in the endovascular repair of perforation of the IVC wall occurring during the retrieval of a penetrated Gunther tulip vena cava filter (Cook, Bjaeverskov, Denmark) after long-term implantation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Influence of Vessel Size and Tortuosity on In-stent Restenosis After Stent Implantation in the Vertebral Artery Ostium

Purpose: Percutaneous transluminal angioplasty and stenting is emerging as an alternative for treating atherosclerotic stenosis in the vertebral artery ostium. However, in-stent restenosis (ISR) still remains a critical issue to be addressed. Little is known about the relationship between anatomic characteristics of the artery and ISR after stent implantation. In this study, we have evaluated influential factors for ISR in a cohort of the patients with stenting in the vertebral artery ostium. Methods: Sixty-one patients with 63 symptomatic lesions in vertebral artery ostium treated with stenting were enrolled onto this study. An average of 12.5 months' clinical and angiographic follow-up results were analyzed retrospectively. The possible influential factors for ISR, including conventional risk factors of cerebrovascular diseases and morphological characteristics of target lesions, were evaluated by univariate and multivariate regression analysis. Results: Technical success was achieved in all 63 interventional procedures. Stenosis was reduced from (mean {+-} standard deviation) 75.5 {+-} 12% before to 1 {+-} 3.6% after the procedure. During the mean 12.5-month angiographic follow-up, ISR was detected in 17 treated vessels (27.0%), with 2 treated arteries (3.2%) resulting in occlusion, and a stent fracture in 1 case (1.6%). Multivariate Cox regression analysis showed that the tortuosity of V1 (hazard ratio 3.54, P = 0.01) and smaller diameter of the stent (hazard ratio 3.8, P = 0.04) were independent predictors of ISR. Conclusions: Angioplasty and stenting for symptomatic stenosis in the vertebral artery ostium stenosis seem to be feasible and effective. Tortuosity and smaller diameter may affect ISR after stent implantation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Perigraft Plug Embolization of the Internal Iliac Artery and Implantation of a Bifurcated Stentgraft: One Treatment Option for Insufficient Tubular Stentgraft Repair of a Common Iliac Artery Aneurysm

We report an endovascular technique for the treatment of type Ia endoleak after a plain tubular stentgraft had been implanted for a large common iliac artery aneurysm with an insufficient proximal landing zone and without occlusion of the hypogastric in another hospital. CT follow-up showed an endoleak with continuous sac expansion over 12 months. This was classified as type Ia by means of dynamic contrast-enhanced MRI. Before a bifurcated stentgraft was implanted to relocate the landing zone more proximally, the still perfused ipsilateral hypogastric artery was embolized to prevent a type II endoleak. A guidewire was manipulated alongside the indwelling stentgraft. The internal iliac artery could then be selectively intubated followed by successful plug embolization of the vessel’s orifice despite the stentgraft being in place.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Understanding heterogeneity in Genesis diamond-like carbon film using SIMS analysis of implants

An amorphous diamond-like carbon film deposited on silicon made at Sandia National Laboratory by pulsed laser deposition was one of several solar wind (SW) collectors used by the Genesis Mission (NASA Discovery Class Mission #5). The film was ~1 μm thick, amorphous, anhydrous, and had a high ratio of sp 3 –sp 2 bonds (>50%). For 27 months of exposure to space at the first We passively irradiated lagrange point, the collectors, with SW (H fluence ~2 × 10 16 ions cm -2 ; He fluence ~8 × 10 14 ions cm -2 ). The radiation damage caused by the implanted H ions peaked at 12–14 nm below the surface of the film and that of He about 20–23 nm. To enable quantitative measurement of the SW fluences by secondary ion mass spectroscopy, minor isotopes of Mg ( 25 Mg and 26 Mg) were commercially implanted into flight-spare collectors at 75 keV and a fluence of 1 × 10 14 ions cm -2 . Furthermore, the shapes of analytical depth profiles, the rate at which the profiles were sputtered by a given beam current, and the intensity of ion yields are used to characterize the structure of the material in small areas (~200 × 200 ± 50 μm). Data were consistent with the hypothesis that minor structural changes in the film were induced by SW exposure.

36 MATERIALS SCIENCE↗

An introduction to the practical and ethical perspectives on the need to advance and standardize the intracoelomic surgical implantation of electronic tags in fish

The intracoelomic surgical implantation of electronic tags (including radio and acoustic telemetry transmitters, passive integrated transponders and archival biologgers) is frequently used for conducting studies on fish. Electronic tagging studies provide information on the spatial ecology, behavior and survival of fish in marine and freshwater systems. However, any surgical procedure, particularly one where a laparotomy is performed and the coelomic cavity is opened, has the potential to alter the survival, behavior or condition of the animal which can impair welfare and introduce bias. Given that management, regulatory and conservation decisions are based on the assumption that fish implanted with electronic tags have similar fates and behavior relative to untagged conspecifics, it is critical to ensure that best surgical practices are being used. Also, the current lack of standardized surgical procedures and reporting of specific methodological details precludes cross-study and cross-year analyses which would further progress the field of fisheries science. This compilation of papers seeks to identify the best practices for the entire intracoelomic tagging procedure including pre- and post-operative care, anesthesia, wound closure, and use of antibiotics. Although there is a particular focus on salmonid smolts given the large body of literature available on that group, other life-stages and species of fish are discussed where there is sufficient knowledge. Additional papers explore the role of the veterinarian in fish surgeries, the need for minimal standards in the training of fish surgeons, providing a call for more complete and transparent procedures, and identifying trends in procedures and research needs. Collectively, this body of knowledge should help to improve data quality (including comparability and repeatability), enhance management and conservation strategies, and maintain the welfare status of tagged fish.

60 APPLIED LIFE SCIENCES↗

Training considerations for the intracoelomic implantation of electronic tags in fish with a summary of common surgical errors

Training is a fundamental part of all scientific and technical disciplines. This is particularly true for all types of surgeons. For surgical procedures, a number of skills are necessary to reduce mistakes. Trainees must learn an extensive yet standardized set of problem-solving and technical skills to handle challenges as they arise. There are currently no guidelines or consistent training methods for those intending to implant electronic tags in fish; this is surprising, considering documented cases of negative consequences of fish surgeries and information from studies having empirically tested fish surgical techniques. Learning how to do fish surgery once is insufficient for ensuring the maintenance or improvement of surgical skill. Assessment of surgical skills is rarely incorporated into training, and is needed. Evaluation provides useful feedback that guides future learning, fosters habits of self-reflection and self-remediation, and promotes access to advanced training. Veterinary professionals should be involved in aspects of training to monitor basic surgical principles. We identified attributes related to knowledge, understanding, and skill that surgeons must demonstrate prior to performing fish surgery including a “hands-on” assessment using live fish. Included is a summary of common problems encountered by fish surgeons. We conclude by presenting core competencies that should be required as well as outlining a 3-day curriculum for training surgeons to conduct intracoelomic implantation of electronic tags. This curriculum could be offered through professional fisheries societies as professional development courses.

59 BASIC BIOLOGICAL SCIENCES↗

Modulation of the electronic states of perovskite SrCrO 3 thin films through protonation via low-energy hydrogen plasma implantation approaches

Hydrogenation of transition metal oxides offers a powerful platform to tailor physical functionalities as well as for potential applications in modern electronic technologies. An ideal nondestructive and efficient hydrogen incorporation approach is important for the realistic technological applications. We demonstrate the proton injection on SrCrO 3 thin films via an effecient low-energy hydrogen plasma implantation experiments, without destroying the original lattice framework. Hydrogen ions accumulate largely at the interfacial regions with amorphous character which extend about one-third of the total thickness. The H x SrCrO 3 (HSCO) thin films appear like exfoliated layers which however retain the fully strained state with distorted perovskite structure. Proton doping induces the change of Cr oxidation state from Cr 4+ to Cr 3+ in HSCO thin films and a transition from metallic to insulating phase. As a result, our investigations suggest an attractive platform in manipulating the electronic phases in proton-based approaches and may offer a potential peeling off strategy for nanoscale devices through low-energy hydrogen plasma implantation approaches.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Laser Desorption/Ionization Mass Spectrometric Imaging of Endogenous Lipids from Rat Brain Tissue Implanted with Silver Nanoparticles

Mass spectrometry imaging (MSI) of tissue implanted with silver nanoparticulate (AgNP) matrix generates reproducible imaging of lipids in rodent models of disease and injury. Gas-phase production and acceleration of size-selected 8 nm AgNP is followed by controlled ion beam rastering and soft landing implantation of 500 eV AgNP into tissue. Focused 337 nm laser desorption produces high quality images for most lipid classes in rat brain tissue (in positive mode: galactoceramides, diacylglycerols, ceramides, phosphatidylcholines, cholesteryl ester, and cholesterol, and in negative ion mode: phosphatidylethanolamides, sulfatides, phosphatidylinositol, and sphingomyelins). Image reproducibility in serial sections of brain tissue is achieved within <10% tolerance by selecting argentated instead of alkali cationized ions. The imaging of brain tissues spotted with pure standards was used to demonstrate that Ag cationized ceramide and diacylglycerol ions are from intact, endogenous species. In contrast, almost all Ag cationized fatty acid ions are a result of fragmentations of numerous lipid types having the fatty acid as a subunit. Almost no argentated intact fatty acid ions come from the pure fatty acid standard on tissue. .

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Large-scale atomistic simulations of low-energy helium implantation into tungsten single crystals

Large-scale molecular dynamics simulations of post-implantation helium behavior in plasma-facing tungsten single crystals reveal orientation-dependent depth profiles, surface evolution patterns, and other crystallographic and diffusion-related characteristics of helium behavior in tungsten during the first microsecond. Here, the flux of implanted helium atoms studied, Γ ≈ 4 × 10 25 m -2 s -1 , is about one order of magnitude larger than that expected in ITER, the experimental fusion reactor currently being constructed in France. With simulation times on the order of 1 μs, these results serve to discover the mechanisms involved in surface evolution as well as to serve as benchmarks for coarse-grained simulations such as kinetic Monte Carlo and continuum-scale drift–reaction–diffusion cluster dynamics simulations. The findings of our large-scale simulations are significant due to diminished finite-size effects and the longer times reached (corresponding to higher fluences). Specifically, our findings are drastically different from findings published previously in the literature for (001) surfaces under a helium flux of Γ ~ 10 28 m -2 s -1 , which is typical of smaller size and shorter time atomistic simulations. In particular, this study highlights the atomic-scale materials processes relevant to helium entrapment and transport in metals, which have implications not only for nuclear fusion–relevant processes, but also helium-induced embrittlement in irradiated materials such as hospital equipment and fission reactor materials.

36 MATERIALS SCIENCE↗

Bubble formation in helium-implanted nanostructured ferritic alloys at elevated temperatures

Helium bubble formation was examined by scanning/transmission electron microscopy (S/TEM) in Fe-9/10Cr binary alloys and two dispersion strengthened nanostructured alloys (CNA3 and 14YWT containing 5–10 nm diameter carbide and oxide particles, respectively) after ex-situ and in-situ He implantation to ~10,000 appm at 500 to 900 °C. The combination of high-resolution STEM images and electron energy loss spectroscopy (EELS) revealed that the Y-Ti-O nanoparticles in 14YWT were uniformly distributed and exhibited a one-to-one relationship for bubble attachment to the nanoclusters. In the in-situ experiment at 900 °C, grain boundary cracking was severe in the Fe-10Cr model alloy, but not in the nanostructured alloys. From 500 to 900 °C, the bubble size generally increased with increasing irradiation temperature, while the bubble density decreased with increasing temperature. At the same temperatures, the bubble size in the implanted materials was in the order of Fe-9/10Cr > CNA3 > 14YWT, while the bubble density showed the opposite order. The observed bubble number densities for the nanostructured alloys are comparable to the nanoparticle density, suggesting that the nanoparticles in both alloys were effective in trapping He. Overall, our results indicate that very high He concentrations can be managed in nanostructured alloys by sequestering the helium into smaller bubbles (which leads to a lower volume swelling value) and to shield He from the grain boundaries. This can be attributed to the much higher sink strength associated with the nanoclusters or the He trapping ability between different types of nanoclusters.

36 MATERIALS SCIENCE↗

Low thermal budget dopant activation in shallow junctions of implanted Si via Tunable plasma enhanced annealing

Low thermal budget (LTB) annealing has become increasingly critical for shallow junctions as semiconductor devices are scaled down. Plasma Enhanced Annealing (PEA) has emerged as a promising LTB annealing process, however its mechanisms remain unclear. In this study, arsenic and boron implanted silicon wafers were subjected to helium or argon ion bombardment generated by annealing plasmas under controlled ion energies and doses in a home-built annealing reactor. The structural and electrical changes were characterized by four-point probe measurements, secondary ion mass spectrometry, Raman spectroscopy and spectroscopic ellipsometry. A pronounced reduction in sheet resistance, accompanied by a decrease in the damage layer thickness demonstrates the surface selective annealing capability of PEA process. Comparative studies using He and Ar plasmas and related ion bombardment reveal a dependence of activation efficacy on both ion species and the dopant implantation profile. Furthermore, a multi-step annealing mechanism is proposed, consisting of an initial (low dose) structural recovery stage followed by the generation of “extended” defects and concluded at large doses by an enhanced dopant activation. The proposed annealing kinetics are thought to be controlled by ion flux, dose and energy. Finally, these results highlight PEA as an effective, surface-selective, LTB approach for shallow-dopant activation and near surface annealing, and provide mechanistic insights into PEA processes.

dopant activation↗

Orders of magnitude reduction in the thermal conductivity of polycrystalline diamond through carbon, nitrogen, and oxygen ion implantation

Despite the exceptional thermal and mechanical functionalities of diamond, its superlative properties are highly subject to the presence of point defects, dislocations, and interfaces. Here, polycrystalline diamond is ion implanted with C 3+ , N 3+ , and O 3+ ions at an energy of 16.5 MeV, producing an amorphous layer at the projected range and a damaged crystalline region between the surface and amorphous layer. Using time-domain thermoreflectance in combination with thermal penetration depth calculations based upon the multilayer heat diffusion equation, it is determined that reductions in the thermal conductivity can span nearly two orders of magnitude while still maintaining a polycrystalline structure within the regions thermally probed. Dynamical diffraction simulations of high-resolution x-ray diffraction measurements demonstrate the formation of a strained layer localized at the end of range, with much lower levels of strain near the surface. Furthermore, within the polycrystalline region above the amorphous layer, the average number of displacements-per-atom from the ion irradiation is found to be < 1%, with mass impurity concentrations much less than 1%. These low defect concentrations within the thermally probed region demonstrate the remarkably large impact that dilute levels of defects from the ion implantation can have on the thermal conductivity of diamond.

36 MATERIALS SCIENCE↗

The structural modification and magnetism of many-layer epitaxial graphene implanted with low-energy light ions

Modifying the properties of graphene has gained wide interest for a plethora of potential applications, including spintronics. One approach has demonstrated that proton irradiation can induce ferromagnetism in graphene as well as in graphite. However, little is known about how the protons interact with graphene, the mechanism that creates the ferromagnetism, or whether the protons remain in the graphene. Here we report an investigation, broadly relevant to graphitic carbon, using low-energy (360–2000 eV) ions of hydrogen, deuterium, and helium implanted into multilayer epitaxial graphene. Complementary x-ray and neutron reflectivity demonstrate that essentially all of the implanted hydrogen remains chemisorbed in graphene. In situ x-ray diffraction reveals significantly different rates of interlayer expansion of the multilayer graphene. Analysis of these data demonstrates that the interlayer expansion arises entirely from the interstitials created by the ions and not from hydrogen that remains in the graphene. The results also establish a quantitative measure of the layer expansion due to carbon interstitials. Magnetometry and x-ray diffraction studies show that the magnetic moment relates to the amount of interstitial carbon rather than the amount of hydrogen, demonstrating that the induced room-temperature ferromagnetism arises directly from the disrupted bonding of the carbon lattice.

36 MATERIALS SCIENCE↗