Search NASA⌕ Search

SEARCH · Search NASA

Results for “Imaging System Camera”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Relationships between summertime surface albedo and melt pond fraction in the central Arctic Ocean: The aggregate scale of albedo obtained on the MOSAiC floe

As part of the Multidisciplinary drifting Observatory for the Study of Arctic Climate (MOSAiC), the HELiX uncrewed aircraft system (UAS) was deployed over the sea ice in the central Arctic Ocean during summer 2020. Albedo measurements were obtained with stabilized pyranometers, and melt pond fraction was calculated from orthomosaic imagery from a surface-imaging multispectral camera. This study analyzed HELiX flight data to provide insights on the temporal and spatial evolution of albedo and melt pond fraction of the MOSAiC floe during the melt season as it drifted south through Fram Strait. The surface albedo distributions showed peak values changing from high albedo (0.55–0.6) to lower values (0.3) as the season advanced. Inspired by methods developed for satellite data, an algorithm was established to retrieve melt pond fraction from the orthomosaic images. We demonstrate that the near-surface observations of melt pond fraction were highly dependent on sample area, offering insight into the influence of subgrid scale features and spatial heterogeneity in satellite observations. Vertical observations conducted with the HELiX were used to quantify the influence of melt pond scales on observed surface albedo as a function of sensor footprint. These scaling results were used to link surface-based measurements collected during MOSAiC to broader-scale satellite data to investigate the influence of surface features on observed albedo. Albedo values blend underlying features within the sensor footprint, as determined by the melt pond size and concentration. This study framed the downscaling (upscaling) problem related to the airborne (surface) observations of surface albedo across a variety of spatial scales.

54 ENVIRONMENTAL SCIENCES↗

Simultaneous, single-pulse, synchrotron x-ray imaging and diffraction under gas gun loading

We develop a mini gas gun system for simultaneous, single-pulse, x-ray diffraction and imaging under high strain-rate loading at the beamline 32-ID of the Advanced Photon Source. In order to increase the reciprocal space covered by a small-area detector, a conventional target chamber is split into two chambers: a narrowed measurement chamber and a relief chamber. The gas gun impact is synchronized with synchrotron x-ray pulses and high-speed cameras. Depending on a camera’s capability, multiframe imaging and diffraction can be achieved. The proof-of-principle experiments are performed on single-crystal sapphire. The diffraction spots and images during impact are analyzed to quantify lattice deformation and fracture; diffraction peak broadening is largely caused by fracture-induced strain inhomogeneity. Finally, our results demonstrate the potential of such multiscale measurements for revealing and understanding high strain-rate phenomena at dynamic extremes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

PROBING THE MSP PRENATAL STAGE: THE OPTICAL IDENTIFICATION OF THE X-RAY BURSTER EXO 1745-248 IN TERZAN 5

We report on the optical identification of the neutron star burster EXO 1745-248 in Terzan 5. The identification was performed by exploiting Hubble Space Telescope/Advanced Camera for Surveys images acquired in Director's Discretionary Time shortly after (approximately one month) the Swift detection of the X-ray burst. The comparison between these images and previous archival data revealed the presence of a star that is currently brightened by ∼3 mag, consistent with expectations during an X-ray outburst. The centroid of this object well agrees with the position, in the archival images, of a star located in the turn-off/sub-giant-branch region of Terzan 5. This supports the scenario that the companion should have recently filled its Roche Lobe. Such a system represents the prenatal stage of a millisecond pulsar, an evolutionary phase during which heavy mass accretion on the compact object occurs, thus producing X-ray outbursts and re-accelerating the neutron star.

79 ASTRONOMY AND ASTROPHYSICS↗

Application of IR imaging for free-surface velocity measurement in liquid-metal systems

Measuring free-surface, liquid-metal flow velocity is challenging to do in a reliable and accurate manner. This paper presents a non-invasive, easily calibrated method of measuring the surface velocities of open-channel liquid-metal flows using an IR camera. Unlike other spatially limited methods, this IR camera particle tracking technique provides full field-of-view data that can be used to better understand open-channel flows and determine surface boundary conditions. Lastly, this method could be implemented and automated for a wide range of liquid-metal experiments, even if they operate at high-temperatures or within strong magnetic fields.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

MO-FG-CAMPUS-JeP3-04: Feasibility Study of Real-Time Ultrasound Monitoring for Abdominal Stereotactic Body Radiation Therapy

Purpose: Ultrasound is ideal for real-time monitoring in radiotherapy with high soft tissue contrast, non-ionization, portability, and cost effectiveness. Few studies investigated clinical application of real-time ultrasound monitoring for abdominal stereotactic body radiation therapy (SBRT). This study aims to demonstrate the feasibility of real-time monitoring of 3D target motion using 4D ultrasound. Methods: An ultrasound probe holding system was designed to allow clinician to freely move and lock ultrasound probe. For phantom study, an abdominal ultrasound phantom was secured on a 2D programmable respiratory motion stage. One side of the stage was elevated than another side to generate 3D motion. The motion stage made periodic breath-hold movement. Phantom movement tracked by infrared camera was considered as ground truth. For volunteer study three healthy subjects underwent the same setup for abdominal SBRT with active breath control (ABC). 4D ultrasound B-mode images were acquired for both phantom and volunteers for real-time monitoring. 10 breath-hold cycles were monitored for each experiment. For phantom, the target motion tracked by ultrasound was compared with motion tracked by infrared camera. For healthy volunteers, the reproducibility of ABC breath-hold was evaluated. Results: Volunteer study showed the ultrasound system fitted well to the clinical SBRT setup. The reproducibility for 10 breath-holds is less than 2 mm in three directions for all three volunteers. For phantom study the motion between inspiration and expiration captured by camera (ground truth) is 2.35±0.02 mm, 1.28±0.04 mm, 8.85±0.03 mm in LR, AP, SI directly, respectively. The motion monitored by ultrasound is 2.21±0.07 mm, 1.32±0.12mm, 9.10±0.08mm, respectively. The motion monitoring error in any direction is less than 0.5 mm. Conclusion: The volunteer study proved the clinical feasibility of real-time ultrasound monitoring for abdominal SBRT. The phantom and volunteer ABC studies demonstrated sub-millimeter accuracy of 3D motion movement monitoring.

60 APPLIED LIFE SCIENCES↗

A new fixation aid for the radiotherapy of eye tumors

A modified swim goggle holding a light spot as an optical guide for actively aligning the eye in a reproducible orientation has been constructed to perform radiotherapy of ocular tumors. This device is compatible with computed tomography (CT) and magnetic resonance imaging systems. Image fusion of these data sets yielded clinically acceptable results. The reproducibility of the eye's positioning is tested by repeated CT. The eye's alignment during radiotherapy is monitored by an infrared TV camera with individual markings of the eye's position on the TV-monitor screen. From 2003-2006, 50 patients were treated with this fixation aid by radiosurgery with good patient compliance.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Smart Methane Emission Detection System Development (Final Report)

Working with the Department of Energy's National Energy Technology Laboratory, Southwest Research Institute® (SwRI®) developed a system to identify methane leaks reliably, accurately, and autonomously at critical midstream sections of the natural gas distribution network in real-time for the purpose of mitigating methane emissions using Optical Gas Imaging (OGI) cameras. SwRI's Smart Leak Detection – Methane (SLED/M) adds a high degree of automation to the process of methane leak detection to minimize sources of human error, minimize response time to a leak event, and maximize midstream visibility. Furthermore, SwRI has been working towards integrating Quantitative OGI (QOGI) capabilities into this existing technology. By leveraging Deep Learning, SwRI now has the capability to estimate fugitive emission leak rates quickly and reliably, which allows operators to detect emissions, quantify leak rate, prioritize repairs, and validate the repairs in a single instrument. The next generation QOGI technology leverages the same cameras used in Leak Detection and Repair (LDAR) programs, with improvements in safety and speed for traditional quantification-based repairs, ultimately leading to less overhead cost for the operators. The goals for this research were to develop two types of models with the following goals: Run in real-time on the edge (≥ 12 Hz), Classification: Achieve less than 5% false positive detection, Classification: Achieve ≥ 95% methane plume detection rate, Regression: achieve ≤ 10 standard cubic feet per hour (scfh) prediction > 70% of the time. In order to achieve these results, multiple infrared (IR) and other sensors were investigated in tandem with the midwave IR (MWIR) OGI to provide additional information to train the underlying models. Information on atmospheric conditions including humidity, temperature, pressure, and solar radiation was provided by a weather station. Several machine learning and deep learning architectures and methods, including looking at quantized classification networks and regressions networks, were explored. As further data was collected, curated, and labeled, it allowed for more refined regressive networks to be adequately trained, leading to better insight into the true flow rates being observed. An important valuable deliverable of this research effort was the development of an advanced network which underwent multiple iterations capable of giving a continuous output. The current network has a predicted mean average percentage error (MAPE) of 12.3% just outside our target goal of 10.00%, but an accuracy of 97.78% at ±50 scfh, well within the overall goal for the Department of Energy (DOE) program. Upon closer inspection, it was observed that more than 10% of datapoints contributing to the MAPE predictions were the result of low flow rate predictions and are beyond the sensitivity of instrument measurement as a result of normal operational variation and noise.

03 NATURAL GAS↗

Digital camera imagery for vegetation phenology, Seward Peninsula, Alaska, 2019-2021

Time lapse camera images from Kougarok mile marker (MM) 64 and Teller MM 27 NGEE-Arctic field sites on the Seward Peninsula, Alaska, captured from July 2019 to August 2021. Thirty three Wingscape Timelapse Pro cameras were deployed targeting patches of low and tall shrubs (including Alnus sp. and Salix sp.) and general vegetation and landscape views. Images from were recorded at hourly intervals from 11 AM to 2 PM, continuously for 25 months and capture vegetation phenology, snow accumulation and snow melt events. This data package includes images (*.jpg), organized by site and camera ID, and metadata with details of the cameras used, number of images recorded, start and end dates, GPS locations and example fields of view. The Next-Generation Ecosystem Experiments: Arctic (NGEE Arctic), was a research effort to reduce uncertainty in Earth System Models by developing a predictive understanding of carbon-rich Arctic ecosystems and feedbacks to climate. NGEE Arctic was supported by the Department of Energy's Office of Biological and Environmental Research. The NGEE Arctic project had two field research sites: 1) located within the Arctic polygonal tundra coastal region on the Barrow Environmental Observatory (BEO) and the North Slope near Utqiagvik (Barrow), Alaska and 2) multiple areas on the discontinuous permafrost region of the Seward Peninsula north of Nome, Alaska. Through observations, experiments, and synthesis with existing datasets, NGEE Arctic provided an enhanced knowledge base for multi-scale modeling and contributed to improved process representation at global pan-Arctic scales within the Department of Energy's Earth system Model (the Energy Exascale Earth System Model, or E3SM), and specifically within the E3SM Land Model component (ELM).

54 ENVIRONMENTAL SCIENCES↗

Digital camera imagery for vegetation phenology, Seward Peninsula, Alaska, 2022-2023

Timelapse camera images from Council Mile Marker (MM) 71, Kougarok MM 64, Kougarok Fire Complex (KFC), and Teller MM 27 NGEE-Arctic field sites on the Seward Peninsula, Alaska, captured from July 2022 to July 2023. Eight Wingscape Timelapse Pro cameras, and thirty-one Power-interval Camera Automation Modules (PiCAMs) designed by Brookhaven National Laboratory?s Terrestrial Ecosystem Science and Technology (TEST) group were deployed targeting patches of low and tall shrubs (including Alnus sp. and Salix sp.) and general vegetation and landscape views. Images from Wingscape cameras were recorded at hourly intervals from 11 AM to 2 PM, and images from PiCAMs were recorded at 5 hourly intervals from 12 AM to 8 PM, continuously for 12 months and capture vegetation phenology, snow accumulation and snow melt events. This data package includes images (*.jpg), organized by site and camera ID, and metadata with details of the cameras used, number of images recorded, start and end dates, GPS locations and example fields of view. The Next-Generation Ecosystem Experiments: Arctic (NGEE Arctic), was a research effort to reduce uncertainty in Earth System Models by developing a predictive understanding of carbon-rich Arctic ecosystems and feedbacks to climate. NGEE Arctic was supported by the Department of Energy's Office of Biological and Environmental Research. The NGEE Arctic project had two field research sites: 1) located within the Arctic polygonal tundra coastal region on the Barrow Environmental Observatory (BEO) and the North Slope near Utqiagvik (Barrow), Alaska and 2) multiple areas on the discontinuous permafrost region of the Seward Peninsula north of Nome, Alaska. Through observations, experiments, and synthesis with existing datasets, NGEE Arctic provided an enhanced knowledge base for multi-scale modeling and contributed to improved process representation at global pan-Arctic scales within the Department of Energy's Earth system Model (the Energy Exascale Earth System Model, or E3SM), and specifically within the E3SM Land Model component (ELM).

54 ENVIRONMENTAL SCIENCES↗

The Dark Energy Survey CCD imager design

The Dark Energy Survey is planning to use a 3 sq. deg. camera that houses a {approx} 0.5m diameter focal plane of 62 2kx4k CCDs. The camera vessel including the optical window cell, focal plate, focal plate mounts, cooling system and thermal controls is described. As part of the development of the mechanical and cooling design, a full scale prototype camera vessel has been constructed and is now being used for multi-CCD readout tests. Results from this prototype camera are described.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Stereo-particle image velocimetry uncertainty quantification

Particle image velocimetry (PIV) measurements are subject to multiple elemental error sources and thus estimating overall measurement uncertainty is challenging. Recent advances have led to a posteriori uncertainty estimation methods for planar two-component PIV. However, no complete methodology exists for uncertainty quantification in stereo PIV. In the current paper, a comprehensive framework is presented to quantify the uncertainty stemming from stereo registration error and combine it with the underlying planar velocity uncertainties. The disparity in particle locations of the dewarped images is used to estimate the positional uncertainty of the world coordinate system, which is then propagated to the uncertainty in the calibration mapping function coefficients. Next, the calibration uncertainty is combined with the planar uncertainty fields of the individual cameras through an uncertainty propagation equation and uncertainty estimates are obtained for all three velocity components. The methodology was tested with synthetic stereo PIV data for different light sheet thicknesses, with and without registration error, and also validated with an experimental vortex ring case from 2014 PIV challenge. Thorough sensitivity analysis was performed to assess the relative impact of the various parameters to the overall uncertainty. The results suggest that in absence of any disparity, the stereo PIV uncertainty prediction method is more sensitive to the planar uncertainty estimates than to the angle uncertainty, although the latter is not negligible for non-zero disparity. Overall the presented uncertainty quantification framework showed excellent agreement between the error and uncertainty RMS values for both the synthetic and the experimental data and demonstrated reliable uncertainty prediction coverage. Finally, this stereo PIV uncertainty quantification framework provides the first comprehensive treatment on the subject and potentially lays foundations applicable to volumetric PIV measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Application of IR imaging for free-surface velocity measurement in liquid-metal systems

Measuring free-surface, liquid-metal flow velocity is challenging to do in a reliable and accurate manner. This paper presents a non-invasive, easily-calibrated method of measuring the surface velocities of open-channel liquid-metal flows using an IR camera. Unlike other spatially-limited methods, this IR camera particle tracking technique provides full field-of-view data that can be used to better understand open-channel flows and determine surface boundary conditions. This method could be implemented and automated for a wide range of liquid-metal experiments, even if they operate at high-temperatures or within strong magnetic fields.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Application of IR imaging for free-surface velocity measurement in liquid-metal systems

Measuring free-surface, liquid-metal flow velocity is challenging to do in a reliable and accurate manner. This paper presents a non-invasive, easily-calibrated method of measuring the surface velocities of open-channel liquid-metal flows using an IR camera. Unlike other spatially-limited methods, this IR camera particle tracking technique provides full field-of-view data that can be used to better understand open-channel flows and determine surface boundary conditions. This method could be implemented and automated for a wide range of liquid-metal experiments, even if they operate at high-temperatures or within strong magnetic fields.

Free surface↗

THE GLOBULAR CLUSTER SYSTEM OF THE COMA CD GALAXY NGC 4874 FROM HUBBLE SPACE TELESCOPE ACS AND WFC3/IR IMAGING

We present new Hubble Space Telescope (HST) optical and near-infrared (NIR) photometry of the rich globular cluster (GC) system NGC 4874, the cD galaxy in the core of the Coma cluster (Abell 1656). NGC 4874 was observed with the HST Advanced Camera for Surveys in the F475W (g {sub 475}) and F814W (I {sub 814}) passbands and with the Wide Field Camera 3 IR Channel in F160W (H {sub 160}). The GCs in this field exhibit a bimodal optical color distribution with more than half of the GCs falling on the red side at g {sub 475}−I {sub 814} > 1. Bimodality is also present, though less conspicuously, in the optical-NIR I {sub 814}−H {sub 160} color. Consistent with past work, we find evidence for nonlinearity in the g {sub 475}−I {sub 814} versus I {sub 814}−H {sub 160} color–color relation. Our results thus underscore the need for understanding the detailed form of the color–metallicity relations in interpreting observational data on GC bimodality. We also find a very strong color–magnitude trend, or “blue tilt,” for the blue component of the optical color distribution of the NGC 4874 GC system. A similarly strong trend is present for the overall mean I {sub 814}−H {sub 160} color as a function of magnitude; for M {sub 814} < −10 mag, these trends imply a steep mass–metallicity scaling with Z∝M{sub GC}{sup 1.4±0.4}, but the scaling is not a simple power law and becomes much weaker at lower masses. As in other similar systems, the spatial distribution of the blue GCs is more extended than that of the red GCs, partly because of blue GCs associated with surrounding cluster galaxies. In addition, the center of the GC system is displaced by 4 ± 1 kpc toward the southwest from the luminosity center of NGC 4874, in the direction of NGC 4872. Finally, we remark on a dwarf elliptical galaxy with a noticeably asymmetrical GC distribution. Interestingly, this dwarf has a velocity of nearly −3000 km s{sup −1} with respect to NGC 4874; we suggest it is on its first infall into the cluster core and is undergoing stripping of its GC system by the cluster potential.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-G-JeP4-04: Commissioning and Acceptance Testing of Optical Surface Monitoring System On TrueBEAM STx as Per Task Group 147

Purpose: Optical Surface Monitoring system (OSMS) have been recently introduced by Varian for initial patient positioning and real-time monitoring during complex radiotherapy treatment. The purpose of this work was to implement TG 147 with OSMS. Methods: Recently we installed OSMS first of its kind in India on trueBEAM STx at our Institue. The OSMS is composed of a three cameras ceiling mounted and a Workstation. The following tests were performed to validate the system a. Calibration b. System reproducibility and drift c. Static localization displacement accuracy and d. Dynamic radiation gating delivery. The Calibration procedure consists of Daily,Monthly and MV Radiation Isocenter Calibration. The reproducibility of system was tested by monitoring the varian gating phantom test pattern for at least 120 min. Each recorded pattern was registered to the reference surface to calculate the required couch adjustment. To measure the static localization displacement accuracy of the system to detect and quantify patient shift relative to a reference image,we compared the shift detected by the surface imaging system with known couch transitions in a phantom study. The phantom was set in a motion and the radiation beam was holded by changing the threshold in the software for different clinical setups to test the dynamic radiation gating capability. Results: Daily calibration was within ±0.5 mm. The MV radiation isocentre with respect to cameras was less than 1 mm in translational axis and less than 0.5° for rotational axis. The reproducibility was found to be 0.4 mm. The maximum static displacement accuracy was 0.75 mm for the three translational axis, and less than 0.5° for rotational axis. The system was able to hold the beam with a minimum threshold of 1 mm. Conclusion: A quality assurance process has been developed as per TG 147 for the clinical implementation of an OSMS in radiation therapy.

60 APPLIED LIFE SCIENCES↗

Development of Thermal Tomography Imaging System for In-Service Nondestructive Evaluation of Additively Manufactured Components

Additive manufacturing (AM) is an emerging method for cost-efficient fabrication of nuclear reactor parts. AM of metallic structures for nuclear energy applications is currently based on laser powder bed fusion (LPBF) process, which can introduce internal material flaws, such as pores and anisotropy. Integrity of AM structures needs to be evaluated nondestructively because material flaws could lead to premature failures due to exposure to high temperature, radiation and corrosive environment in a nuclear reactor. Thermal tomography (TT) provides a capability for non-destructive evaluation of sub-surface defects in arbitrary size structures. We investigate TT of AM stainless steel 316L specimen with imprinted internal porosity defects using relatively low-cost, small form factor infrared (IR) camera based on uncooled micro bolometer detector. Sparse coding related K-means singular value decomposition (SVD) machine learning, image processing algorithms are developed to improve quality of TT images through removal of Additive white Gaussian noise without blurring the images. Following initial qualification of an AM component for deployment in a nuclear reactor, a compact TT can also be used for in-service nondestructive evaluation (NDE). With capability to perform in-service NDE of the AM component lifecycle, TT data can be used for development of a component digital twin. MIT research reactor (MITR) has been identified as a representative environment to perform investigation of feasibility of in-service NDE during shutdown. Preliminary study of radiation level in the MITR viewport, with geometric parameters potentially compatible with compact TT system, has been conducted.

36 MATERIALS SCIENCE↗

Design and Implementation of an In?Cache Archival Entropy Coder for the Sonoma Persistent Surveillance System

The Sonoma sensor, developed at Lawrence Livermore National Laboratory, is an electro-optical (EO) sensor composed of a tiled arrangement of cameras, where each camera sends 20 megabytes (MB) of raw data per frame. Depending on the sensor configuration, each sensor image, in aggregate, can total up to 320 MB. I discuss here the design and implementation of a high-speed entropy coder utilizing the Lead-1 encoding method, intended to quickly and losslessly compress sensor data before it is written to storage. More sophisticated (and slower) compression techniques may be performed off-line. The coder, favoring speed over coding efficiency, is simple in principle and tiny in practice: the amount of allocated memory required by the coder can be as small as 26 bytes. On a 2.7 GHz PowerMac G5 this coder is capable of encoding sensor data at a rate of 163 megabytes per second. The overall compression rate is better than that of BZIP2, GZIP, and a range coder, and the total execution speed is superior.

99 GENERAL AND MISCELLANEOUS↗

Exploration of the potential of liquid scintillators for real-time 3D dosimetry of intensity modulated proton beams

In this study, the authors investigated the feasibility of using a 3D liquid scintillator (LS) detector system for the verification and characterization of proton beams in real time for intensity and energy-modulated proton therapy. A plastic tank filled with liquid scintillator was irradiated with pristine proton Bragg peaks. Scintillation light produced during the irradiation was measured with a CCD camera. Acquisition rates of 20 and 10 frames per second (fps) were used to image consecutive frame sequences. These measurements were then compared to ion chamber measurements and Monte Carlo simulations. The light distribution measured from the images acquired at rates of 20 and 10 fps have standard deviations of 1.1% and 0.7%, respectively, in the plateau region of the Bragg curve. Differences were seen between the raw LS signal and the ion chamber due to the quenching effects of the LS and due to the optical properties of the imaging system. The authors showed that this effect can be accounted for and corrected by Monte Carlo simulations. The liquid scintillator detector system has a good potential for performing fast proton beam verification and characterization.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗