Search NASA⌕ Search

SEARCH · Search NASA

Results for “LAB”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Cath Lab Robotics: Paradigm Change in Interventional Cardiology?

Purpose of Review: To review the contemporary evidence for robotic-assisted percutaneous coronary and vascular interventions, discussing its current capabilities, limitations, and potential future applications. Recent Findings: Robotic-assisted cardiovascular interventions significantly reduce radiation exposure and orthopedic strains for interventionalists, while maintaining high rates of device and clinical success. The PRECISE and CORA-PCI studies demonstrated the safety and efficacy of robotic-assisted percutaneous coronary intervention (PCI) in increasingly complex coronary lesions. The RAPID study demonstrated similar findings in peripheral vascular interventions (PVI). Subsequent studies have demonstrated the safety and efficacy of second-generation devices, with automations mimicking manual PCI techniques. While innovations such as telestenting continue to bring excitement to the field, major limitations remain—particularly the lack of randomized trials comparing robotic-assisted PCI with manual PCI. Summary: Robotic technology has successfully been applied to multiple cardiovascular procedures. There are limited data to evaluate outcomes with robotic-assisted PCI and other robotic-assisted cardiovascular procedures, but existing data show some promise of improving the precision of PCI while decreasing occupational hazards associated with radiation exposure.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A New Shallow Underground Gas-Proportional Counting Lab - First Results and Ar-37 Sensitivity

Abstract A new ultra-low-background proportional counter was recently developed with an internal volume of 100 ml and has been characterized at pressures from 1-10 atmospheres with P-10 (90% Ar, 10% methane) gas. This design, along with a counting system providing event digitization and passive and active shielding, has been developed to complement a new shallow underground laboratory (30 meters water-equivalent). Backgrounds and low-level reference materials have been measured, and system sensitivity for Ar-37 has been calculated.

argon-37↗

From lab to table: Expanding gastronomic possibilities with fermentation using the edible fungus Neurospora intermedia

Fermentation is a powerful tool for enhancing flavor, improving sustainability, and expanding creative possibilities in the kitchen. However, most fermentations done in gastronomic contexts are restricted to a small set of readily available microbial species. Expanding beyond this limited biological diversity holds promise to unlock new gastronomic innovation. Here, we explore novel culinary applications of Neurospora intermedia, an edible fungus traditionally used in Java, Indonesia to produce the fermented food oncom. Our work demonstrates that N. intermedia can be readily used in the production of oncom-like meat alternatives with non-traditional substrates, as well as in the production of enzymes for starch-to-sugar conversion. As an example, we harness secreted N. intermedia starch-degrading enzymes to produce an amazake that has a distinct volatile aroma composition compared to traditional amazake produced with Aspergillus oryzae. In addition to providing texture and flavor, N. intermedia can be used to add an orange color to dishes due to the development of brightly colored spores and aerial mycelia. This property, along with its secreted enzymes, was utilized to create a dish for fine-dining restaurant Alchemist in Copenhagen, Denmark. Overall, the novel foods produced in this study were rated favorably in consumer trials, indicating a broad sensory appeal of N. intermedia across different culinary applications and cultural contexts. The protocols and approaches presented in this study represent a new addition to the chef's toolbox that hold promise to expand gastronomic possibilities with fermentation in restaurants and beyond.

59 BASIC BIOLOGICAL SCIENCES↗

Glass formulation and lab-scale testing of glasses designed for in-can Melter and in-container Vitrification of high-assay low-enriched uranium aqueous polishing Raffinate waste

Glasses were designed for processing a nuclear waste from aqueous polishing of high-assay low-enriched uranium using either In-Can Melter (ICM) or GeoMelt® In-Container Vitrification™ (ICV) technologies, which operate at temperatures of T p ≤ 1100 °C and T p ≤ 1450 °C, respectively. Due to the different operating conditions, the melt and glass properties were optimized differently for each technology. Each glass was designed to optimize for maximum waste loading while simultaneously satisfying processing (e.g., crystallization, viscosity, and conductivity) and product quality (e.g., durability, hazard characteristic, and crystal content) constraints. Here, the raffinate waste contains high nitric acid (4 M) and low total solids (9 g·L -1 ) concentrations. Feed preparation processes were tested to facilitate concentration and nitrate destruction/removal while controlling redox of the melter feed. A successful feed process including sugar addition and spray-drying was performed to generate an adequate melter feed for ICV processing.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Relationships between fault characteristics and seismic responses in a large lab-scale tri-axial injection test conducted on a faulted Castlegate Sandstone

Here to investigate mechanisms causing microseismicity (M w < 2) at a CO 2 injection site, a large-scale triaxial block experiment was carried out on a faulted (saw-cut) cubic-meter of Castlegate Sandstone. The experiment consisted of injection tests at varying differential stresses, while monitoring and recording pore pressure and acoustic emissions (AEs). During the experiment, ~33,000 AEs and ~14 mm of horizontal displacement/slip, like a strike-slip fault movement, occurred. To understand the AE responses and ascertain fault characteristics near the located AEs, we modeled the topography of the fault surface, fault aperture, and fault-gouge thickness using pre- and post-experiment laser scans of the fault surface on each half of the block. Additionally, we characterized surface roughness parallel and perpendicular to slip. Models show crushing and flattening of the fault surfaces can be linked to the spatiotemporal distribution of AEs within 50 mm of the fault surface. Approximately 65% of AEs were in areas with small aperture (≤300 μm); thicker fault gouge was observed in adjacent areas with wider aperture and shows a two-fold reduction in grain size relative to unaltered Castlegate Sandstone. This work provides a conceptual understanding on fault surface evolution, which can be applied towards modeling of seismic slip.

58 GEOSCIENCES↗

An automated lab-scale flue gas permeation membrane testing system at the National Carbon Capture Center

A constant pressure, mixed gas permeation testing skid was deployed at the National Carbon Capture Center to test membrane performance when continuously exposed to slipstream post-combustion flue gas. Small, laboratory scale membranes can be loaded for testing and the degree of automation allowed the skid to be run unattended for several weeks at a time. In this report, we share our experience in commissioning the skid and quantifying CO 2 , N 2 and O 2 permeances of several membranes during the first round of testing. Dense films of polydimethylsiloxane and poly(bistrifluoroethoxyphosphazene) were tested with flue gas for approximately 20 h each. Here, in addition, we successfully tested four thin film composite hollow fiber membranes made by a dip coating process, consisting of porous Torlon hollow fibers coated with a selective layer of poly(bistrifluoroethoxyphosphazene) or its mixed matrix with a metal organic framework SIFSIX-Cu-2i filler particles. Initial results suggest the polydimethylsiloxane showed comparable results to the literature data, but the coated hollow fiber membranes have lower CO 2 permeances relative to N 2 or O 2 permeances compared to their performance under idealized, dry, contaminant-free mixed gas conditions. While quantification of H 2 O permeance was performed, we found it was affected by concentration polarization even with small membrane area and a low stage cut.

47 OTHER INSTRUMENTATION↗

The Aerogel Cerenkov detector for the SHMS magnetic spectrometer in Hall C at Jefferson Lab

Hadronic reactions producing strange quarks such as exclusive or semi-inclusive kaon production, play an important role in studies of hadron structure and the dynamics that bind the most basic elements of nuclear physics. The small-angle capability of the new Super High Momentum Spectrometer (SHMS) in Hall C, coupled with its high momentum reach - up to the anticipated 11-GeV beam energy in Hall C - and coincidence capability with the well-understood High Momentum Spectrometer, will allow for probes of such hadron structure involving strangeness down to the smallest distance scales to date. To cleanly select the kaons, a threshold aerogel Cerenkov detector has been constructed for the SHMS. The detector consists of an aerogel tray followed by a diffusion box. Four trays for aerogel of nominal refractive indices of n =1.030, 1.020, 1.015 and 1.011 were constructed. The tray combination will allow for identification of kaons from 1 GeV/c up to 7.2 GeV/c, reaching 10 -2 proton and 10 -3 pion rejection, with kaon detection efficiency better than 95%. The diffusion box of the detector is equipped with 14 five-inch diameter photomultiplier tubes. Its interior walls are covered with Gore diffusive reflector, which is superior to the commonly used Millipore paper and improved the detector performance by 35%. The inner surface of the two aerogel trays with higher refractive index is covered with Millipore paper, however, those two trays with lower aerogel refractive index are again covered with Gore diffusive reflector for higher performance. The measured mean number of photoelectrons in saturation is ~12 for n =1.030, ~8 for n =1.020, ~10 for n =1.015, and ~5.5 for n =1.011. Here the design details, the results of component characterization, and initial performance tests and optimization of the detector are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗