Search NASA⌕ Search

SEARCH · Search NASA

Results for “Linear accelerators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Japanese Structure Survey of Radiation Oncology in 2007 Based on Institutional Stratification of Patterns of Care Study

Purpose: To evaluate the ongoing structure of radiation oncology in Japan in terms of equipment, personnel, patient load, and geographic distribution to identify and improve any deficiencies. Methods and Materials: A questionnaire-based national structure survey was conducted from March to December 2008 by the Japanese Society of Therapeutic Radiology and Oncology (JASTRO). These data were analyzed in terms of the institutional stratification of the Patterns of Care Study. Results: The total numbers of new cancer patients and total cancer patients (new and repeat) treated with radiation in 2007 were estimated at 181,000 and 218,000, respectively. There were 807 linear accelerator, 15 telecobalt, 46 Gamma Knife, 45 {sup 60}Co remote-controlled after-loading, and 123 {sup 192}Ir remote-controlled after-loading systems in actual use. The linear accelerator systems used dual-energy function in 539 units (66.8%), three-dimensional conformal radiation therapy in 555 (68.8%), and intensity-modulated radiation therapy in 235 (29.1%). There were 477 JASTRO-certified radiation oncologists, 826.3 full-time equivalent (FTE) radiation oncologists, 68.4 FTE medical physicists, and 1,634 FTE radiation therapists. The number of interstitial radiotherapy (RT) administrations for prostate, stereotactic body radiotherapy, and intensity-modulated radiation therapy increased significantly. Patterns of Care Study stratification can clearly identify the maturity of structures based on their academic nature and caseload. Geographically, the more JASTRO-certified physicians there were in a given area, the more RT tended to be used for cancer patients. Conclusions: The Japanese structure has clearly improved during the past 17 years in terms of equipment and its use, although a shortage of personnel and variations in maturity disclosed by Patterns of Care Study stratification were still problematic in 2007.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Autoencoder Based Analysis of RF Parameters in the Fermilab Low Energy Linac

Machine learning (ML) has the potential for significant impact on the modeling, operation, and control of particle accelerators due to its ability to model nonlinear behavior, interpolate on complicated surfaces, and adapt to system changes over time. Anomaly detection in particular has been highlighted as an area where ML can significantly impact the operation of accelerators. These algorithms work by identifying subtle behaviors of key variables prior to negative events. Efforts to apply ML to anomaly detection have largely focused on subsystems such as RF cavities, superconducting magnets, and losses in rings. However, dedicated efforts to understand how to apply ML for anomaly detection in linear accelerators have been limited. In this paper the use of autoencoders is explored to identify anomalous behavior in measured data from the Fermilab low-energy linear accelerator.

Edelen, Jonathan P. (ORCID:0000000215180652)↗

Proposal for an astronaut mass measurement device for the Space Shuttle

For medical reasons, astronauts in space need to have their mass measured. Currently, this measurement is performed using a mass-spring system. The current system is large, inaccurate, and uncomfortable for the astronauts. NASA is looking for new, different, and preferably better ways to perform this measurement process. After careful analysis our design team decided on a linear acceleration process. Within the process, four possible concept variants are put forth. Among these four variants, one is suggested over the others. The variant suggested is that of a motor-winch system to linearly accelerate the astronaut. From acceleration and force measurements of the process combined Newton's second law, the mass of an astronaut can be calculated.

Beyer, Neil↗

Epid Dosimetry

Electronic portal imaging devices (EPIDs) were introduced originally for patient position verification. The idea of using EPIDs for dosimetry was realised in the 1980s. Little was published on the topic until the mid 1990's, when the interest in EPIDs for dosimetry increased rapidly and continues to grow. The increasing research on EPID dosimetry coincided with the introduction of intensity modulated radiation therapy (IMRT). EPIDs are well suited to IMRT dosimetry because they are high resolution, two-dimensional (2D) digital detectors. They are also pre-existing on almost all modern linear accelerators. They generally show a linear response to increasing dose. Different types of EPIDs have been clinically implemented, and these have been described in several review papers. The current generation of commercially available EPIDs are indirect detection active matrix flat panel imagers, also known as amorphous silicon (a-Si) EPIDs. Disadvantages of a-Si EPIDs for dosimetry include non-water equivalent construction materials, and the energy sensitivity and optical scatter of the phosphor scintillators used to create optical signal from the megavoltage beam. This report discusses current knowledge regarding a-Si EPIDs for dosimetry.

61 RADIATION PROTECTION AND DOSIMETRY↗

Translational Vestibulo-Ocular Reflexes During Off-Vertical Axis Rotation

The translational vestibulo-ocular reflex (tVOR) is an otolith-mediated response that stabilizes near vision during linear acceleration at higher frequencies where visually mediated reflexes are not adequate. The modulation of horizontal and vergence eye movements during Off-Vertical Axis Rotation (OVAR) are presumed to reflect the tVOR in response to the continuously varying linear acceleration in the interaural and nasooccipital axes, respectively. The purpose of this study was to examine the effect of frequency and fixation distance on the modulation of slow phase eye velocity (SPV) as further evidence that the tVOR is elicited during OVAR. Eighteen subjects were rotated about their longitudinal axis tilted by 30 deg off-vertical. Rotational velocities varied between 18 and 288 deg/sec corresponding to a frequency range of 0.05 to 0.8 Hz. Fixation distance was altered by asking subjects to imagine stationary targets that were briefly presented at 0.5, 1 and 2 m during some rotation cycles. The target flash was 40 msec in the nose-up position at eye level. Oculomotor responses were recorded in the dark using infrared binocular videography. Sinusoidal curve fits were used to derive amplitude, phase and bias velocity of the eye movements across multiple rotation cycles. Consistent with previous studies, the modulation of both horizontal and vergence SPV increased with stimulus frequency. The effect of fixation distance was negligible at lower frequencies. The modulation of horizontal and vergence SPV was; however, proportional to fixation distance during OVAR at 0.8 Hz. This increasing sensitivity and dependence on fixation distance of horizontal and vergence SPV during OVAR is consistent with tVOR characteristics measured during other types of linear motion. We conclude that the modulation of horizontal and vergence SPV will be diagnostically more useful at higher stimulus frequencies where the tVOR is more robust.

Wood, Scott J.↗

Total Marrow Irradiation With RapidArc Volumetric Arc Therapy

Purpose: To develop a volumetric arc therapy (VMAT)-total marrow irradiation (TMI) technique for patients with hematologic malignancies. Methods and Materials: VMAT planning was performed for 6 patients using RapidArc technology. The planning target volume consisted of all the bones in the body from the head to the mid-femur, excluding the extremities, except for the humerus, plus a 3.0-mm margin. The organs at risk included the lungs, heart, liver, kidneys, bowels, brain, eyes, and oral cavity. The VMAT-TMI technique consisted of three plans: the head and neck, the chest, and the pelvis, each with three 330{sup o} arcs. The plans were prescribed to ensure, at a minimum, 95% planning target volume dose coverage with the prescription dose (percentage of volume receiving dose of {>=}12 Gy was 95%). The treatments were delivered and verified using MapCheck and ion chamber measurements. Results: The VMAT-TMI technique reported in the present study provided comparable dose distributions with respect to the fixed gantry linear accelerator intensity-modulated TMI. RapidArc planning was less subjective and easier, and, most importantly, the delivery was more efficient. RapidArc reduced the treatment delivery time to approximately 18 min from 45 min with the fixed gantry linear accelerator intensity-modulated TMI. When the prescription dose coverage was reduced to 85% from 95% and the mandible and maxillary structures were not included in the planning target volume as reported in a tomotherapy study, a considerable organ at risk dose reduction of 4.2-51% was observed. The average median dose for the lungs and lenses was reduced to 5.6 Gy from 7.2 Gy and 2.4 Gy from 4.5 Gy, respectively. Conclusion: The RapidArc VMAT technique improved the treatment planning, dose conformality, and, most importantly, treatment delivery efficiency. The results from our study suggest that the RapidArc VMAT technology can be expected to facilitate the clinical transition of TMI.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Illusory sensations in aircraft flight and weightlessness

Clearly misleading illusions only appear when the vestibular input is of a nonconflicting nature. A number of experiments with blind goldfish were conducted since the vestibular system of the goldfish is homologous in many respects to that of man. Inertial stimuli were given by linear acceleration of the entire aquarium with the fish in it. A high-speed movie camera and three-axis accelerometers were used to record the fish responses. It was found that fish, if subjected to horizontal linear acceleration, behave as if the moving force acting on the otoliths were a gravitational force component and not an inertial reacting force.

Von Baumgarten, R. J.↗

Mo-99 Concentration and processing by Solvent Extraction and Ion Exchange

Normally derived from its transient-equilibrium parent molybdenum-99 ( 99 Mo) (t½ = 66 h), the short-lived isotope technetium-99m ( 99m Tc) (t ½ = 6.0 h) is the most widely used medical isotope in diagnostic imaging today. The National Nuclear Security Administration’s (NNSA’s) Material Management and Minimization (M3) program—established under the auspices of the American Medical Isotope Production Act—has been tasked with facilitating the work of domestic 99 Mo suppliers that do not use highly enriched uranium (HEU). Superconducting electron linear accelerators that employ high-Z converter targets can generate bremsstrahlung photons and neutron fluxes that can induce photonuclear reactions and uranium (U) fission. Argonne, in collaboration with industrial partners, has been developing the process chemistry for superconducting linear accelerator (LINAC)-irradiated triuranium octoxide (U 3 O 8 ) targets to produce 99 Mo. In short, the process involves dissolving the irradiated targets in nitric acid, which simultaneously releases valuable fission products (xenon and iodine). After adjusting the acid concentration, producers process the feed using tri-n-butyl phosphate (TBP), then mix the raffinate derived from this extraction cycle with a phosphinic acid such as Cyanex 272 or di(2-ethylhexyl) phosphoric acid (HDEHP), which is selective for Mo (molybdenum liquid liquid extraction [MoLLE]). In the next step, a concentration column comprising an anion exchange platform is used to decontaminate the remaining fission products, generating a pure 99 Mo stream in sodium hydroxide (NaOH)/sodium chloride (NaCl).

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

The radioactive ion beam production systems for the SPIRAL2 project

The SPIRAL2 project, currently under construction at GANIL, will include an isotope separator on line based facility for the production and acceleration of radioactive ion beams. A superconducting linear accelerator will accelerate 5 mA deuterons up to 40 MeV and 1 mA heavy ions up to 14.5 MeV/u. These primary beams will be used to bombard both thick and thin targets. We are investigating three different techniques to produce the radioactive ion beams: (1) the neutron induced fission of uranium carbide, (2) the direct interaction of deuterons in a uranium carbide target, and (3) the interaction of a heavy ion beam with a target. All these production systems will be coupled to an ion source. Four kinds of ion sources are foreseen for the ionization of the radioactive atoms: an electron cyclotron resonance ion source, a surface ionization ion source, a forced electron beam induced arc discharge ion source, and a laser ion source depending on the characteristics of the desired radioactive ion beam in terms of intensity, efficiency, purity, etc. A presentation of the SPIRAL2 project and of the different production systems is given.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The ReA electron-beam ion trap charge breeder for reacceleration of rare isotopes

ReA is a post-accelerator at the National Superconducting Cyclotron Laboratory at Michigan State University. ReA is designed to reaccelerate rare isotopes to energies of a few MeV/u following production by projectile fragmentation and thermalization in a gas cell. The facility consists of four main components: an electron-beam ion trap (EBIT) charge breeder, an achromatic charge-over-mass (Q/A) separator, a radio-frequency quadrupole accelerator, and a superconducting radio-frequency linear accelerator. The EBIT charge breeder was specifically designed to efficiently capture continuous beams of singly charged ions injected at low energy (<60 keV), charge breed in less than 50 ms, and extract highly charged ions to the Q/A separator for charge-state selection and reacceleration through the accelerator structures. The use of highly charged ions to reach high beam energies is a key aspect that makes ReA a compact and cost-efficient post-accelerator. The EBIT is characterized by a high-current electron gun, a long multi-electrode trap structure and a dual magnet to provide both the high electron-beam current density necessary for fast charge breeding of short-lived isotopes as well as the high capture probability of injected beams. This paper presents an overview and the status of the ReA EBIT, which has extracted for reacceleration tests stable {sup 20}Ne{sup 8+} ion beams produced from injected gas and more recently {sup 39}K{sup 16+} beams by injecting stable {sup 39,41}K{sup +} ions from an external ion source.

43 PARTICLE ACCELERATORS↗

SU-E-T-270: Diffusion Synthetic Acceleration for Linear Boltzmann Transport Equation

Purpose: Linear Boltzmann transport equation (LBTE) is as accurate as the Monte Carlo method (MC) for dose calculation in photon/particle therapy (LBTE is a deterministic and Eulerian formulation and MC is a statistical and Lagrangian description). An advantage of LBTE is that numerous acceleration techniques can be utilized for acceleration. This work is to explore the acceleration of LBTE via diffusion synthetic acceleration (DSA). Methods: For simplicity, two-dimensional, steady-state, and within-group LBTE is considered with two angular dimensions and two spatial dimensions. The discrete ordinate method is developed for solving this integro-differential equation. The angular variables are discretized using a level-symmetric quadrature set on the unit sphere. The spatial variables are discretized on the structured grid based on the diamond scheme. The source-iteration method (SI) is used to solve the discretized system.Since SI is slow in optically thick and highly scattering regime. DSA is developed to accelerate SI. The motivation for DSA is that diffusion equation (DE) is a good approximation of LBTE in the above regime. However, DE is much cheaper than LBTE computationally since DE only involves spatial variables. Thus, in each DSA iteration, DSA adds to the SI step a computationally-negligible DE step, i.e., to first solve DE with the SI residual as source term, and then compensate the SI solution with DE solution. Results: DSA was benchmarked and compared with SI. The difference between two methods was within 0.12% which verifies the accuracy of DSA, while DSA demonstrated the great advantage in speed, e.g., the reduction of iteration number to 6% and 4% respectively for cases with 100 and 1,000 scattering-absorption ratio that commonly occur in clinical dose calculation. Conclusion: DSA has been developed as one of many possible means for accelerating the numerical solver of LBTE for dose calculation. The authors were partially supported by the NSFC (#11405105), the 973 Program (#2015CB856000) and the Shanghai Pujiang Talent Program (#14PJ1404500)

60 APPLIED LIFE SCIENCES↗

International Linear Collider Accelerator Physics R&D

ILC work at Illinois has concentrated primarily on technical issues relating to the design of the accelerator. Because many of the problems to be resolved require a working knowledge of classical mechanics and electrodynamics, most of our research projects lend themselves well to the participation of undergraduate research assistants. The undergraduates in the group are scientists, not technicians, and find solutions to problems that, for example, have stumped PhD-level staff elsewhere. The ILC Reference Design Report calls for 6.7 km circumference damping rings (which prepare the beams for focusing) using “conventional” stripline kickers driven by fast HV pulsers. Our primary goal was to determine the suitability of the 16 MeV electron beam in the AØ region at Fermilab for precision kicker studies.We found that the low beam energy and lack of redundancy in the beam position monitor system complicated the analysis of our data. In spite of these issues we concluded that the precision we could obtain was adequate to measure the performance and stability of a production module of an ILC kicker, namely 0.5%. We concluded that the kicker was stable to an accuracy of ~2.0% and that we could measure this precision to an accuracy of ~0.5%. As a result, a low energy beam like that at AØ could be used as a rapid-turnaround facility for testing ILC production kicker modules. The ILC timing precision for arrival of bunches at the collision point is required to be 0.1 picosecond or better. We studied the bunch-to-bunch timing accuracy of a “phase detector” installed in AØ in order to determine its suitability as an ILC bunch timing device. A phase detector is an RF structure excited by the passage of a bunch. Its signal is fed through a 1240 MHz high-Q resonant circuit and then down-mixed with the AØ 1300 MHz accelerator RF. We used a kind of autocorrelation technique to compare the phase detector signal with a reference signal obtained from the phase detector’s response to an event at the beginning of the run. We determined that the device installed in our beam, which was instrumented with an 8-bit 500 MHz ADC, could measure the beam timing to an accuracy of 0.4 picoseconds. Simulations of the device showed that an increase in ADC clock rate to 2 GHz would improve measurement precision by the required factor of four. As a result, we felt that a device of this sort, assuming matters concerning dynamic range and long-term stability can be addressed successfully, would work at the ILC. Cost effective operation of the ILC will demand highly reliable, fault tolerant and adaptive solutions for both hardware and software. The large numbers of subsystems and large multipliers associated with the modules in those subsystems will cause even a strong level of unit reliability to become an unacceptable level of system availability. An evaluation effort is underway to evaluate standards associated with high availability, and to guide ILC development with standard practices and well-supported commercial solutions. One area of evaluation involves the Advanced Telecom Computing Architecture (ATCA) hardware and software. We worked with an ATCA crate, processor monitors, and a small amount of ATCA circuit boards in order to develop a backplane “spy” board that would let us watch the ATCA backplane communications and pursue development of an inexpensive processor monitor that could be used as a physics-driven component of the crate-level controls system. We made good progress, and felt that we had determined a productive direction to extend this work. We felt that we had learned enough to begin designing a workable processor monitor chip if there were to be sufficient interest in ATCA shown by the ILC community. Fault recognition is a challenging issue in the crafting a high reliability controls system. With tens of thousands of independent processors running hundreds of thousands of critical processes, how can the system identify that a problem has arisen and determine the appropriate steps to take to correct, or compensate, for the failure? One possible solution might come through the use of the OpenClovis supervisory system, which runs on Linux processors and allows a select set of processors to monitor the behavior of individual processes and processors in a large, distributed controls network. We found that OpenClovis exhibited an irritating amount of sensitivity to the exact version of the Linux kernel running on the processors, and that it was poorly equipped to help us sort through problems that arose through conflicts so deep in the operating systems of the processors. But once this issue was addressed, we found that it performed as expected, recognizing crashes and process (and processor) failures.

43 PARTICLE ACCELERATORS↗

Large-acceptance linac for accelerating l9w-energy muons

We propose a high-gradient linear accelerator for accelerating low-energy muons and pions in a strong solenoidal magnetic field. The acceleration starts immediately after collection of pions from a target by solenoidal magnets and brings muons to a kinetic energy of about 200 MeV over a distance of the order of 10 m. At this energy, both an ionization cooling of the muon beam and its further acceleration in a superconducting linac become feasible. The project presents unique challenges - a very large energy spread in a highly divergent beam, as well as pion and muon decays - requiring large longitudinal and transverse acceptances. One potential solution incorporates a normal-conducting linac consisting of independently fed O-mode RF cavities with wide apertures closed by thin metal windows or grids. The guiding magnetic field is provided by external superconducting solenoids. The cavity choice, overall linac design considerations, and simulation results of muon acceleration are presented. While the primary applications of such a linac are for homeland defense and industry, it can provide muon fluxes high enough to be of interest for physics experiments.

43 PARTICLE ACCELERATORS↗

Evaluation of Computed Tomography Techniques for Material Identification in Low Level and Intermediate Level Waste - 16648

Measures required to assure long term safe storage of Low-level and intermediate-level short-lived (LIL/SL) waste generated by the nuclear-power industry in France include the characterization of the waste and identification of materials within the waste. Digital Radiography (DR) techniques using x-ray at energies in the 6 MeV range have been shown to be effective for validation of the integrity of the concrete containers, and it was considered that the use of this technique together with the addition of Computed Tomography (CT) techniques could effectively identify materials within the waste. This paper describes the initial evaluation of two DR imaging techniques and two CT techniques using x-ray energy spectra up to 9 MeV to inspect a surrogate waste package, which comprised an outer concrete cylindrical container of 1400 mm diameter with 148 mm wall thickness, and an overall volume of 2 meters cubed, within which a 200 liter drum containing representative heterogeneous inactive waste, was placed in the center and the annulus between the 200 liter drum and the outer cylindrical package was filled with cement grout. The surrogate waste within the 200 liter drum comprised three separate layers of high density, medium density and low density mixed materials. The equipment used was a linear accelerator producing high energy spectra at either 6 MeV or 9 MeV and a high-precision CT manipulator with X, Y, Z and rotation motions, which were common to all techniques investigated. Two different digital detectors were used in the DR and CT performance evaluations, a Digital Detector Array (DDA) comprising a columnar Thallium-doped Cesium-Iodide scintillator screen in intimate contact with a 2 k by 2 k array of amorphous silicon detectors, 200 μm x 200 μm in area, and a Linear Diode Array (LDA) comprising a line of Cadmium-Tungstate columns, 1 cm thick and 400 μm x 400 μm in area. The work comprised evaluations of linear accelerator spectra and the attenuation effects of the waste container and contents, image acquisition performance of each detector, and CT techniques using area detector and linear detector. The results presented in this paper include mathematical evaluation of the two CT techniques, and analysis of measurement data, digital images, CT reconstruction images, and estimated material densities. The data was compared with recorded details and photographs of the actual configuration of materials within the surrogate waste. The Digital Detector Array can generate CT inspection volumes with considerable resolution and detail for the low-density and medium-density sections of the surrogate waste, however, the high-density sections were not imaged with sufficient detail and the images contained a large number of artifacts mainly due to the detectors lack of high energy photon stopping power. Materials identification with the Digital Detector Array, while possible for certain materials, for materials in the steel to plastic density range the attenuation values of the voxels in the reconstruction are too similar and difficult to resolve from the artifacts present. The Linear Diode Array can generate CT inspection volumes of regions of interest of the low-density and medium-density sections with considerable resolution and contrast, and potentially acceptable levels of resolution and contrast of the high-density section of the waste. While a few artifacts were present in the reconstructions, the majority are not due to the fundamental properties of the detector and are considered to be correctable. Materials identification with the LDA inspection data appear to be viable, with steel, copper, and higher-density metals being readily be distinguished from other materials on the basis of voxel value. Future work is needed to obtain a better definition of optimum spatial resolution and inspection speed, and to develop a system of 'calibration rods' which would consist of a series of 50 mm diameter cylinders of 7 materials; Plastic, Teflon, Concrete, Aluminum, Copper, Tungsten and Lead. The cylinders will be distributed at a certain radius in the surrogate waste and will be used as reference points in the evaluation and demonstration of the contrastive performance for the low, medium and high-density cases. The ability to identify the materials within a sealed waste container, by nondestructive examination, enables the verification of waste acceptance criteria without the need to open the waste containers. This eliminates the need for complex and expensive equipment to open and remotely handle the intermediate level waste, avoids potential hazards and risk of personnel dose uptake, and does not increase the volume of waste caused by repackaging of materials after examination and the decontamination or disposal of equipment used.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Low-Frequency Otolith Function in Microgravity: A Re-Evaluation of the Otolith Tilt-Translation Reinterpretation (OTTR) Hypothesis

On Earth, the low-frequency afferent signal from the otoliths encodes head tilt with respect to the gravitational vertical, and the higher frequency components reflect both tilt and linear acceleration of the head. In microgravity, static tilt of the head does not influence otolith output, and the relationship between sensory input from the vestibular organs, and the visual, proprioceptive and somatosensory systems, would be disrupted. Several researchers have proposed that in 0-g this conflict may induce a reinterpretation of all otolith signals by the brain to encode only linear translation (otolith tilt-translation reinterpretation or OTTR). Ocular counter-rolling (OCR) is a low-frequency otolith-mediated reflex, which generates compensatory torsional eye movements (rotation about the visual axis) towards the spatial vertical during static roll tilt with a gain of approximately 10%. Transient linear acceleration and off-axis centrifugation at a constant angular velocity can also generate OCR. According to the OTTR hypothesis, OCR should be reduced in microgravity, and immediately upon return from a 0-g environment. Results to date have been inconclusive. OCR was reduced following the 10 day Spacelab-1 mission in response to leftward roll tilts (28-56% in 3 subjects and unchanged in one subject), and sinusoidal linear oscillations at 0.4 and 0.8 Hz. OCR gain declined 70% in four monkeys following a 14 day COSMOS mission. Following a 30 day MIR mission OCR gain decreased in one astronaut, but increased in two others following a 180 day mission. We have studied the affect of microgravity on low-frequency otolith function as part of a larger study of the interaction of vision and the vestibular system. This experiment (E-047) involved off-axis centrifugation of payload crewmembers and flew aboard the recent Neurolab mission (STS 90). Presented below are preliminary results focusing on perception and the OCR response during both centrifugation and static tilt.

Moore, Steven T.↗

Demonstration of transmission high energy electron microscopy

High energy electrons have been used to investigate an extension of transmission electron microscopy. This technique, transmission high energy electron microscopy (THEEM), provides two additional capabilities to electron microscopy. First, high energy electrons are more penetrating than low energy electrons, and thus, they are able to image through thicker samples. Second, the accelerating mode of a radio-frequency linear accelerator provides fast exposures, down to 1 ps, which are ideal for flash radiography, making THEEM well suited to study the evolution of fast material processes under dynamic conditions. Lastly, initial investigations with static objects and during material processing have been performed to investigate the capabilities of this technique.

47 OTHER INSTRUMENTATION↗

New generation bunch shape monitor for ion accelerators

Measuring longitudinal beam parameters is important for operation and development of high intensity linear accelerators, but it is notoriously difficult for proton and ion beams at non-relativistic energies. The Bunch Shape Monitor (BSM) is a device used for measuring the longitudinal bunch distribution in ion linacs. The existing BSM models have poor electron collection efficiency from the wire and are limited to one-dimensional measurements of the phase coordinate. In response to this problem, we have developed a new generation BSM with improved performance. The proposed design incorporates three major innovations: First, the collection efficiency was improved by adding a focusing field between the wire and the entrance slit, which will also allow measurements over a much wider dynamic range. Second, an improvement in the measurement speed was achieved by sampling longitudinal profiles of multiple energy slices simultaneously, where the BSM wire is placed at the exit of an ion spectrometer so that ions with different energies hit the wire at different horizontal coordinates along the wire. Finally, the design incorporates a motion system that can shift the wire and deflecting cavity together, enabling transverse profile measurements like a wire scanner. Here, in this paper, we will provide the design of the new BSM and report on its beam test results at the Spallation Neutron Source facility in Oak Ridge National Laboratory.

43 PARTICLE ACCELERATORS↗

Localized Dose Enhancement to Tumor Blood Vessel Endothelial Cells via Megavoltage X-rays and Targeted Gold Nanoparticles: New Potential for External Beam Radiotherapy

Purpose: Tumor endothelial cell damage during radiation therapy may contribute significantly to tumor eradication and treatment efficacy. Gold nanoparticles (AuNPs) delivered preferentially to the walls of tumor blood vessels produce low-energy, short-range photoelectrons during external beam radiotherapy, boosting dose to the tumor microvasculature. In this study dosimetry at the single-cell level is used to estimate the anticipated AuNP-mediated dose enhancement to tumor endothelial cells during 6-MV X-ray irradiation. Methods and Materials: Endothelial cells are modeled as thin slabs with 100-nm-diameter AuNPs attached within the blood vessel. The number of photoelectrons emitted per AuNP per gray of X-rays is computed at multiple points along the external beam central axis by use of a Monte Carlo-generated energy fluence spectrum. The energy deposited from AuNP emissions to the endothelium is calculated based on an analytic method incorporating the energy-loss formula of Cole. The endothelial dose enhancement factor (EDEF) is the ratio of the overall (externally plus internally generated) dose to endothelial cells in the presence of AuNPs to the dose without AuNPs (from the external beam only). Results: At 20-cm depth, the EDEF is 1.7 (70% dose increase) for an intravascular AuNP concentration of 30 mg/g. Most of this dose enhancement arises from the low-energy (approximately 100 keV) portion of the linear accelerator X-ray spectrum. Furthermore, for AuNP concentrations ranging from 7 to 140 mg/g, EDEF values of 1.2 to 4.4 (20-340% dose increase) are calculated. Conclusions: In contrast to calculations assuming that AuNPs distributed homogeneously throughout the target volume (macrodosimetry), our cellular microdosimetry calculations predict a major dose enhancement to tumor microvasculature from conventional linear accelerator X-rays. This effect may enable the delivery of ablative therapeutic doses to these sensitive microstructures while maintaining established dose constraints for the organs at risk.

62 RADIOLOGY AND NUCLEAR MEDICINE↗