Search NASA⌕ Search

SEARCH · Search NASA

Results for “Load Profile”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Mars entry-to-landing trajectory optimization and closed loop guidance

The guidance strategy of the Mars Rover Sample Return mission is presented in detail. Aeromaneuver versus aerobrake trades are examined, and an aerobrake analysis is presented which takes into account targeting, guidance, flight control, trajectory profile, delivery accuracy. An aeromaneuver analysis is given which includes the entry corridor, maneuver footprint, guidance, preentry phase, constant drag phase, equilibrium guide phase, variable drag phase, influence of trajectory profile on the entry flight loads, parachute deployment conditions and strategies, and landing accuracy. The Mars terminal descent phase is analyzed.

Ilgen, Marc R.↗

Postglacial rebound with a non-Newtonian upper mantle and a Newtonian lower mantle rheology

A composite rheology is employed consisting of both linear and nonlinear creep mechanisms which are connected by a 'transition' stress. Background stress due to geodynamical processes is included. For models with a non-Newtonian upper-mantle overlying a Newtonian lower-mantle, the temporal responses of the displacements can reproduce those of Newtonian models. The average effective viscosity profile under the ice-load at the end of deglaciation turns out to be the crucial factor governing mantle relaxation. This can explain why simple Newtonian rheology has been successful in fitting the uplift data over formerly glaciated regions.

Gasperini, Paolo↗

Satellite Tracking of Shallow Cumulus during CAMP2Ex: The Aerosol and Organization Connection

Shallow moist convection is ubiquitous throughout the tropics and represents a key player in boundary layer processes. Shallow clouds come in many forms, from scattered, short-lived cumulus to organized features that include cold pool boundaries and lines reaching O(100 km) scale lasting several hours. In this study, we explore how cloud morphology and environmental aerosol affect shallow cumulus lifecycle properties. Measuring such influences requires a broad, detailed view of these cloud fields as they grow and decay. Geostationary satellites provide a means to follow the clouds with enhanced spatiotemporal sampling from space. We apply a cloud-tracking tool to study lifecycle properties of shallow cumulus sampled during the NASA Cloud, Aerosol, and Monsoon Processes Philippines Experiment (CAMP2Ex) field campaign of 2019. The mission conducted airborne and shipborne operations over the West Pacific Ocean, in tandem with Rapid Scan imagery from the Advanced Himawari Imager (AHI) on the Japan Meteorological Agency’s (JMA) Himawari-8 satellite. We segment shallow cumulus on AHI 0.5-km visible reflectance during the daylit hours of several research flights that exhibited ideal atmospheric conditions for tracking. We collect the resulting cloud tracks by regions containing airborne sampling of the cloud environments and by two specific segmentation techniques: one optimized for small, disorganized cumulus and the other for larger, organized clouds using suitable thresholds for reflectance and blurring. We present an analysis of cloud lifecycle properties using our dual segmentation approach for various sampled environments of CAMP2Ex. A total of 7 research flights (RFs) exhibited ideal conditions for generating cloud-track ensembles under similar thermodynamic and kinematic profiles but with varying aerosol load. We consider lifetime, track-achieved metrics, and ensemble-fitted growth rates to evaluate the aerosol effect. Cloud elongation, a factor in cloud morphology, is also considered for any potential influence in observed shifts in growth rates. The results suggest that aerosol affects cloud lifecycles more significantly for clouds with larger areas and independent of the elongation factor.

Cloud Tracking↗

A Method for Modeling Household Occupant Behavior to Simulate Residential Energy Consumption

This paper presents a statistical method for modeling the behavior of household occupants to estimate residential energy consumption. Using data gathered by the U.S. Census Bureau in the American Time Use Survey (ATUS), actions carried out by survey respondents are categorized into ten distinct activities. These activities are defined to correspond to the major energy consuming loads commonly found within the residential sector. Next, time varying minute resolution Markov chain based statistical models of different occupant types are developed. Using these behavioral models, individual occupants are simulated to show how an occupant interacts with the major residential energy consuming loads throughout the day. From these simulations, the minimum number of occupants, and consequently the minimum number of multiple occupant households, needing to be simulated to produce a statistically accurate representation of aggregate residential behavior can be determined. Finally, future work will involve the use of these occupant models along side residential load models to produce a high-resolution energy consumption profile and estimate the potential for demand response from residential loads.

American Time Use Survey↗

Job Scheduler-Driven Power Gateway for High Performance Computing

Power gateways in the form of a microgrid can incorporate multiple distributed energy resources (DER) in either grid forming or grid following mode and support high performance computing (HPC) power profiles including the large load-follow requirements observed in multi-user HPC systems. The microgrid’s flexibility to operate in either grid forming or grid following mode and to actively switch between these modes enables baseline power from multiple non-baseline DER while maintaining high power quality metrics for the HPC system. But this enormous flexibility in demand response and time of use shifting is generally programmed independently of any integration with an HPC job scheduler which can better inform the load shaping by the microgrid. While there are many existing approaches where the HPC job scheduler takes in information from the grid to make queue scheduling decisions, this work takes the opposite view and explores a scheduler where the jobs in the queue can directly impact the settings of the grid. Several HPC scheduler strategies are tested where the jobs in the queue directly impact the settings of a microgrid designed for HPC operation which is driving a datacenter with three classes of HPC architectures. The scheduler operation is shown using a microgrid with 64 kW of solar capacity and 320 kWh of battery over a period of 21 days operating with significant low-follow swings, a throttled grid, cloudy conditions, switching between grid following and grid forming modes, and a wide range of battery states-of-charge all while maintaining high quality power metrics. The scheduler provides a mechanism for the job queue to directly impact a power gateway like a microgrid and to improve HPC power outcomes such as maximizing renewable energy usage

microgrid↗

The 48-inch lidar aerosol measurements taken at the Langley Research Center

This report presents lidar data taken between July 1991 and December 1992 using a ground-based 48-inch lidar instrument at the Langley Research Center in Hampton, Virginia. Seventy lidar profiles (approximately one per week) were obtained during this period, which began less than 1 month after the eruption of the Mount Pinatubo volcano in the Philippines. Plots of backscattering ratio as a function of altitude are presented for each data set along with tables containing numerical values of the backscattering ratio and backscattering coefficient versus altitude. The enhanced aerosol backscattering seen in the profiles highlights the influence of the Mount Pinatubo eruption on the stratospheric aerosol loading over Hampton. The long-term record of the profiles gives a picture of the evolution of the aerosol cloud, which reached maximum loading approximately 8 months after the eruption and then started to decrease gradually. NASA RP-1209 discusses 48-inch lidar aerosol measurements taken at the Langley Research Center from May 1974 to December 1987.

Woods, David C.↗

Cyclic Plasticity under Shock Loading in an HCP Metal

Plate impact experiments with pressures from 2 to 20 GPa, including one shock-partial release-reshock experiment, were performed on vacuum hot-pressed S-200F Beryllium. This hexagonal close-packed (HCP) metal shows significant plasticity effects in such conditions. The experiments were modeled in a Lagrangian hydrocode using an experimentally calibrated Preston-Tonks-Wallace (PTW) constitutive model. By using the shock data to constrain a high rate portion of PTW, the model was able to generally match plasticity effects on the measured wave profile (surface velocity) during the shock loading, but not unloading. A backstress-based cyclic plasticity model to capture the quasi-elastic release (Bauschinger-type effect) was explored in order to match the unloading and reloading portions of the measured wave profiles. A comparison is made with other approaches in the literature to capture the cyclic plasticity in shock conditions.

36 MATERIALS SCIENCE↗

Thermal interfaces in dynamic compression experiments

Temperature is a difficult thermodynamic variable to measure in dynamic compression experiments. Optical pyrometry is a general-purpose technique for measuring temperature from a radiant surface, but that surface is often the interface between distinct materials with temperatures that vary spatially along the loading direction. This leads to a fundamental problem: how does the measured interface temperature relate to this temperature profile along the compression axis? Numerical analysis of loading history and thermal diffusion at these interfaces shows that seemingly subtle changes in experiment geometry can lead to very different temperature profiles. We compare these results to laboratory temperature measurements of shock-compressed tin.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The Impact of Behind-the-Meter Heterogeneous Distributed Energy Resources on Distribution Grids: Preprint

The increasing integration of distributed energy resources (DERs) on the electric grid brings new challenges and opportunities for utility grid operations. With the rapid deployment of DERs, there is emerging interest in integrating these controllable devices with utility operations at all levels for monitoring and management. Different types of DERs such as Photovoltaics (PV), energy storage, electric vehicles (EVs), etc. have varying effects on the grid based on how and where they are deployed. Again, the DER deployment and its impact are network-dependent, while the traditional electric grids were not designed to host DERs. To understand the challenges with increasing behind-the-meter (BTM) DERs and to identify the needs in deploying advanced controls, a comprehensive grid impact study is indispensable. This paper investigates the impacts of integrating a mix of DERs in the utility distribution network in Colorado, U.S. Firstly, BTM DERs at the residential scale including distributed PV; battery energy storage systems (BESS); heating, ventilation, and air-conditioning (HVAC) load; electric water heater (EWH) load; and EVs are modeled. The impacts of integrating these resources on the distribution network are evaluated by conducting time-series simulations for different scenarios considering different days to capture the worst-case conditions. Monte Carlo simulations are conducted to generate the realistic EV charging profile. The voltage issues, substation transformer loadings, and critical nodes in the network are identified with the incorporation of uncoordinated EV charging loads and other DER in the network. This analysis helps visualize the DER impact on the grid, identify the challenges, and provides an insight into the new distribution management and control needs to enable reliable and resilient distribution grid operations. Additionally, further analysis is performed to estimate the daily residential electricity cost with the inclusion of DERs under time-of-use tariffs. The result shows the daily residential electricity cost reduced by 20:7% on average with DERs compared to the case without DERs.

27 ARPA - Advanced Research Projects Agency-Energy↗

Real-time combined heat and power operational strategy using a hierarchical optimization algorithm

Existing attempts to optimize the operation of combined heat and power (CHP) systems for building applications have two major limitations: the electrical and thermal loads are obtained from historical weather profiles; and the CHP system models ignore transient responses by using constant equipment efficiencies. This article considers the transient response of a building combined with a hierarchical CHP optimal control algorithm to obtain a real-time integrated system that uses the most recent weather and electric load information. This is accomplished by running concurrent simulations of two transient building models. The first transient building model uses current as well as forecast input information to obtain short-term predictions of the thermal and electric building loads. The predictions are then used by an optimization algorithm (i.e. a hierarchical controller that decides the amount of fuel and of electrical energy to be allocated at the current time step). In a simulation, the actual physical building is not available and, hence, to simulate a real-time environment, a second, building model with similar but not identical input loads are used to represent the actual building. A state-variable feedback loop is completed at the beginning of each time step by copying (i.e. measuring, the state variable from the actual building and restarting the predictive model using these ‘measured’ values as initial conditions). The simulation environment presented in this article features non-linear effects such as the dependence of the heat exchanger effectiveness on their operating conditions. Finally, the results indicate that the CHP engine operation dictated by the proposed hierarchical controller with uncertain weather conditions has the potential to yield significant savings when compared with conventional systems using current values of electricity and fuel prices.

42 ENGINEERING↗

Ascent guidance algorithm using lidar wind measurements

The formulation of a general nonlinear programming guidance algorithm that incorporates wind measurements in the computation of ascent guidance steering commands is discussed. A nonlinear programming (NLP) algorithm that is designed to solve a very general problem has the potential to address the diversity demanded by future launch systems. Using B-splines for the command functional form allows the NLP algorithm to adjust the shape of the command profile to achieve optimal performance. The algorithm flexibility is demonstrated by simulation of ascent with dynamic loading constraints through a set of random wind profiles with and without wind sensing capability.

Cramer, Evin J.↗

Implosion dynamics of triple-nozzle gas-puff z pinches on COBRA

Experiments on the 1-MA, 220-ns COBRA generator at Cornell University were conducted to provide detailed measurements of structured cylindrical gas-puff z pinches. In the experiments, a 7 cm diameter triple-nozzle gas valve assembly with concentric outer and inner annular nozzles and a central gas jet initialize the z-pinch load with various working gases, radial density profiles, and externally applied axial magnetic fields. Planar laser-induced fluorescence provides a measure of the initial neutral gas density of the load, while three-frame laser shearing interferometry and multi-frame extreme ultraviolet (XUV) cameras reveal the formation and propagation of a magneto-Rayleigh–Taylor (MRT) unstable shock layer. Implosion trajectories are compared to simple, experimentally informed models and found to be in good agreement. Differences in the structure of the accelerating plasma sheath and evolution of the MRT instability are observed for different gas species and axial magnetic field strengths, correlating with differences in pinch uniformity and x-ray emission. Here, the average instability growth is compared to linear MRT theory predictions using the instantaneous acceleration of the best-fit implosion models and characteristic instability wavelength, with the effective Atwood number and seed perturbation size as fit parameters. For high density argon center jets, ionization prior to the arrival of the imploding plasma sheath suggests a heating mechanism consistent with photoionization by XUV self-emission.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Demand Response Optimization and Management System for Real-TIme (DROMS-RT)

To design and demonstrate DROMS-RT, a highly distributed Demand Response Optimization and Management System for Real-Time (DROMS-RT) power flow control to support large scale integration of distributed renewable generation into the grid. AutoGrid developed a novel control and communications platform to allow highly dispatchable demand response (DR) services in time frames suitable for providing ancillary services to the transmission grid. These services will be substantially less expensive and more efficient than other forms of ancillary services options currently available to manage the intermittency associated with large-scale renewable integration. DROMSRT successfully leveraged Automated Demand Response (ADR) by fundamentally re-thinking the architecture of the DR platform from the ground up and by developing innovative new technologies in a number of areas related to DR. DROMS-RT leveraged the low-cost, open, interoperable DR signaling technology, OpenADR, and low-cost, internet-protocol based telemetry solutions to reduce the cost of hardware. This allowed DROMS-RT to provide dynamic price signals to millions of OpenADR clients. Statistically rigorous signal processing techniques were developed to reliably detect even small load reductions in the presence of noisy baseline profiles. Novel forecasting engines based on modern online machine learning algorithms enabled accurate individualized forecasts for customer loads in the presence of dynamic pricing signals, and a real-time decision engines enabled continuous optimization and optimal dispatch of DR resources across a large portfolio of heterogeneous loads that respond at varying time-scales. Moreover, the real-time optimization conducted by the decision engine can utilize grid physics to maximize load reduction at the transmission system in addition to the distribution sites, for more efficient grid operation. Finally, the Software-as-a-Service (SaaS) availability of the DROMS-RT platform has reduced the cost of deployment and enable participation of small commercial and residential customers in DR who otherwise would not be able to do so.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Coordinated Optimization of Distributed Energy Resources and Smart Loads in Distribution Systems

Distributed energy resources (DERs) and smart loads have the potential to provide flexibility to the distribution system operation. A coordinated optimization approach is proposed in this paper to actively manage DERs and smart loads in distribution systems to achieve the optimal operation status. A three-phase unbalanced Optimal Power Flow (OPF) problem is developed to determine the output from DERs and smart loads with respect to the system operator's control objective. This paper focuses on coordinating PV systems and smart loads to improve the overall voltage profile in distribution systems. Simulations have been carried out in a 12-bus distribution feeder and results illustrate the superior control performance of the proposed approach.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Coordinated Optimization of Distributed Energy Resources and Smart Loads in Distribution Systems: Preprint

Distributed energy resources (DERs) and smart loads have the potential to provide flexibility to the distribution system operation. A coordinated optimization approach is proposed in this paper to actively manage DERs and smart loads in distribution systems to achieve the optimal operation status. A three-phase unbalanced Optimal Power Flow (OPF) problem is developed to determine the output from DERs and smart loads with respect to the system operator's control objective. This paper focuses on coordinating PV systems and smart loads to improve the overall voltage profile in distribution systems. Simulations have been carried out in a 12-bus distribution feeder and results illustrate the superior control performance of the proposed approach.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Development of an Aeroelastic Modeling Capability for Transient Nozzle Side Load Analysis

Lateral nozzle forces are known to cause severe structural damage to any new rocket engine in development. Currently there is no fully coupled computational tool to analyze this fluid/structure interaction process. The objective of this study was to develop a fully coupled aeroelastic modeling capability to describe the fluid/structure interaction process during the transient nozzle operations. The aeroelastic model composes of three components: the computational fluid dynamics component based on an unstructured-grid, pressure-based computational fluid dynamics formulation, the computational structural dynamics component developed in the framework of modal analysis, and the fluid-structural interface component. The developed aeroelastic model was applied to the transient nozzle startup process of the Space Shuttle Main Engine at sea level. The computed nozzle side loads and the axial nozzle wall pressure profiles from the aeroelastic nozzle are compared with those of the published rigid nozzle results, and the impact of the fluid/structure interaction on nozzle side loads is interrogated and presented.

Wang, Ten-See↗

Off-Design Load Analysis of sCO2 Bottoming Cycle for a Natural Gas Combined Cycle Power Plant with Carbon Capture

This work starts with the optimal design from Pidaparti et. al (2024) to analyze the off-design performance of the power plant from 100% down to 50% load. The main operational findings and plant-efficiency for off-load conditions while maintaining the target CO2 capture rate are presented. The goal of the work is to determine if there is a relative advantage or disadvantage for the sCO2 bottoming cycle compared to the steam bottoming cycle in terms of reduced load efficiency performance for the NGCC with carbon capture. Results show nearly identical efficiency profiles for the two cases from 100% to 50% load.

Chinen, Anderson Soares↗

Development of crystallographic-orientation-dependent internal strains around a fatigue-crack tip during overloading and underloading

In-situ neutron diffraction was employed to directly measure the crystallographic-orientation-dependent (i.e. hkl) internal strains as a function of distance from the crack tip on the pre-cracked Hastelloy C-2000 compact-tension specimen. Both in-plane (IP) and through-thickness (TT) strain evolutions for various grain orientations were examined during tensile overloading and compressive underloading cycles. After overloading, underloading and their combination loadings were applied and unloaded, the significantly different (hkl) residual strain profiles were obtained in the vicinity of the crack tip. The load responses of the (200) grain orientation in both the IP and TT directions were more significant than those of any other orientations. It is suggested that the different orientation-dependent strain distributions around the crack tip are caused by the combined effects of elastic and plastic anisotropy of each (hkl) reflection upon loading and the subsequent development of residual stresses generated near the crack tip during unloading as a result of the plastic deformation. - Highlights: ► (hkl) strains are examined in situ using neutron diffraction. ► Distinct strain responses are developed around the crack tip under loading. ► The strain response of the (200) grain orientation is more significant. ► Possible mechanisms for the orientation-dependent strain responses are provided.

36 MATERIALS SCIENCE↗