Search NASA⌕ Search

SEARCH · Search NASA

Results for “MAGNETIC FIELD COIL”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Performance of a MQXF Nb 3 Sn Quadrupole Magnet Under Different Stress Level

In a dipole or in a quadrupole accelerator magnet, the displacement of the coil turns induced by the electromagnetic forces can cause quenches limiting the magnet performance. For this reason, an azimuthal preload is applied to avoid azimuthal movements of the coil up to the required operational current. However, several tests showed that accelerator magnets can operate with a partial preload, i.e. that coil unloading during the ramp does not prevent reaching higher currents. This issue is particularly relevant for Nb 3 Sn magnets, where the loads applied to the Nb3Sn filaments can reach the degradation limits of critical current. In order to investigate the impact of coil preload on the quench performance, the MQXFS6 short model quadrupole for the High Luminosity Upgrade was tested under an azimuthal preload at 80% of the short sample current, reaching 93% of short sample current at 1.9 K. The preload was then released to 60%, still showing ability to operate in the range of 80-85% of short sample current as required by HL-LHC project. With this lower preload, the ability of going above 90% of short sample was lost, and a significant training appeared above 85%. When the preload was restored to the original 80% value, the magnet reached with few quenches 95% of short sample (13.4 T peak field). Magnetic measurements confirm the larger movement of the coil in the case with lower preload, and agree with finite element simulations.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Conceptual Design of a HTS Dipole Insert Based on Bi2212 Rutherford Cable

The U.S. Magnet Development Program (US-MDP) is aimed at developing high-field accelerator magnets with magnetic fields beyond the limits of Nb 3 Sn technology. Recent progress with composite wires and Rutherford cables based on the first generation high-temperature superconductor Bi 2 Sr 2 CaCu 2 O 8-x (Bi2212) allows considering them for this purpose. However, Bi2212 wires and cables are sensitive to transverse stresses and strains, which are large in high-field accelerator magnets. This requires magnet designs with stress management concepts to control azimuthal and radial strains in the coil windings and prevent the degradation of the current carrying capability of Bi2212 conductor or even its permanent damage. This paper describes a novel stress management approach, which was developed at Fermilab for high-field large-aperture Nb 3 Sn accelerator magnets, and is now being applied to high-field dipole inserts based on Bi2212 Rutherford cables. The insert conceptual design and main parameters, including the superconducting wire and cable, as well as the coil stress management structure, key technological steps and approaches, test configurations and their target parameters, are presented and discussed.

43 PARTICLE ACCELERATORS↗

A tetrahedral probe constellation approach for measuring canonical momentum in self-organized laboratory plasma

To examine momentum redistribution processes and study generalized helicities during plasma relaxation in Madison Symmetric Torus, MST, reversed field pinch plasma, a new probe is being tested to measure the full 3D plasma ion flow and magnetic field vectors at four spatial locations arranged in a tetrahedral shape reminiscent of a satellite measurement constellation. These measurements permit calculation of ∇ x $\vec{u}$ and canonical momentum, where $\vec{u}$ is the plasma ion flow vector. The probe consists of four probe heads arranged in a tetrahedral pattern, with an overall probe diameter of ∼31.75 mm. The probe head diameter is ∼1.0 cm, which is of the order of the ion Larmor radius. Each head has four molybdenum electrodes, also arranged in tetrahedral geometry, which are biased relative to a common return electrode, using four power supplies (one for each head), to measure the local ion flow. Additionally, each head has three orthogonal magnetic pickup coils within it to measure equilibrium and fluctuating magnetic fields.

Physics - Plasma physics↗

Goddard Space Flight Center Spacecraft Magnetic Test Facility Restoration Project

The Goddard Space Flight Center Spacecraft Magnetic Test Facility (SMTF) was constructed in the 1960's for the purpose of simulating geomagnetic and interplanetary magnetic field environments. The facility includes a three axis Braunbek coil system consisting of 12 loops, 4 loops on each of the three orthogonal axes; a remote earth field sensing magnetometer and servo control building; and a remote power control and instrumentation building. The inner coils are 42-foot in diameter and a 10-foot by 10-foot opening through the outer coils accommodates spacecraft access to the test volume. The physical size and precision of the facility are matched by only two other such facilities in the world. The facility was used extensively from the late 1960's until the early 1990's when the requirement for spacecraft level testing diminished. New NASA missions planned under the Living with a Star, Solar Terrestrial Probes, Explorer, and New Millennium Programs include precision, high-resolution magnetometers to obtain magnetic field data that is critical to fulfilling their scientific mission. It is highly likely that future Lunar and Martian exploration missions will also use precision magnetometers to conduct geophysical magnetic surveys. To ensure the success of these missions ground testing using a magnetic test facility such as the GSFC SMTF will be required. This paper describes the history of the facility, the future mission requirements that have renewed the need for spacecraft level magnetic testing, and the plans for restoring the facility to be capable of performing to its original design specifications.

Vernier, Robert↗

Runaway electron deconfinement in SPARC and DIII-D by a passive 3D coil

The operation of a 3D coil—passively driven by the current quench (CQ) loop voltage—for the deconfinement of runaway electrons (REs) is modeled for disruption scenarios in the SPARC and DIII-D tokamaks. Nonlinear magnetohydrodynamic (MHD) modeling is carried out with the NIMROD code including time-dependent magnetic field boundary conditions to simulate the effect of the coil. Further modeling in some cases uses the ASCOT5 code to calculate advection and diffusion coefficients for REs based on the NIMROD-calculated fields, and the DREAM code to compute the runaway evolution in the presence of these transport coefficients. Compared with similar modeling in Tinguely et al (2021 Nucl. Fusion 61 124003), considerably more conservative assumptions are made with the ASCOT5 results, zeroing low levels of transport, particularly in regions in which closed flux surfaces have reformed. Of three coil geometries considered in SPARC, only the n = 1 coil is found to have sufficient resonant components to suppress the runaway current growth. Without the new conservative transport assumptions, full suppression of the RE current is maintained when the thermal quench MHD is included in the simulation or when the RE current is limited to 250kA, but when transport in closed flux regions is fully suppressed, these scenarios allow RE beams on the order of 1–2 MA to appear. Additional modeling is performed to consider the effects of the close ideal wall. In DIII-D, the CQ is modeled for both limited and diverted equilibrium shapes. In the limited shape, the onset of stochasticity is found to be insensitive to the coil current amplitude and governed largely by the evolution of the safety-factor profile. In both devices, prediction of the q-profile evolution is seen to be critical to predicting the later time effects of the coil.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Goddard Space Flight Center Spacecraft Magnetic Test Facility Restoration Project

The Goddard Space Flight Center Spacecraft Magnetic Test Facility (SMTF) was constructed in the 1960's for the purpose of simulating geomagnetic and interplanetary magnetic field environments. The facility includes a three axis Braunbek coil system consisting of 12 loops, 4 loops on each of the three orthogonal axes; a remote Earth field sensing magnetometer and servo controller; and a remote power control and instrumentation building. The inner coils of the Braunbek system are 42-foot in diameter with a 10-foot by 10-foot opening through the outer coils to accommodate spacecraft access into the test volume. The physical size and precision of the facility are matched by only two other such facilities in the world. The facility was used extensively from the late 1960's until the early 1990's when the requirement for spacecraft level testing diminished. New NASA missions planned under the Living with a Star, Solar Terrestrial Probes, Explorer, and New Millennium Programs include precision, high-resolution magnetometers to obtain magnetic field data that is critical to fulfilling their scientific mission. It is highly likely that future Lunar and Martian exploration missions will also use precision magnetometers to conduct geophysical magnetic surveys. To ensure the success of these missions, ground-testing using a magnetic test facility such as the GSFC SMTF will be required. This paper describes the history of the facility, the future mission requirements that have renewed the need for spacecraft level magnetic testing, and the plans for restoring the facility to be capable of performing to its original design specifications.

Vernier, Robert↗

Goddard Space Flight Center Spacecraft Magnetic Test Facility Restoration Project

The Goddard Space Flight Center Spacecraft Magnetic Test Facility (SMTF) was constructed in the 1960's for the purpose of simulating geomagnetic and interplanetary magnetic field environments. The facility includes a three axis Braunbek coil system consisting of 12 loops, 4 loops on each of the three orthogonal axes; a remote Earth field sensing magnetometer and servo controller; and a remote power control and instrumentation building. The inner coils of the Braunbek system are 42-foot in diameter with a 10-foot by 10-foot opening through the outer coils to accommodate spacecraft access into the test volume. The physical size and precision of the facility are matched by only two other such facilities in the world. The facility was used extensively from the late 1960's until the early 1990's when the requirement for spacecraft level testing diminished. New NASA missions planned under the Living with a Star, Solar Terrestrial Probes, Explorer, and New Millennium Programs include precision, high-resolution magnetometers to obtain magnetic field data that is critical to fulfilling their scientific mission. It is highly likely that future Lunar and Martian exploration missions will also use precision magnetometers to conduct geophysical magnetic surveys. To ensure the success of these missions, ground testing using a magnetic test facility such as the GSFC SMTF will be required. This paper describes the history of the facility, the future mission requirements that have renewed the need for spacecraft level magnetic testing, and the plans for restoring the facility to be capable of performing to its original design specifications.

Vernier, Robert↗

A Superconducting transformer system for high current cable testing

This article describes the development of a direct-current (dc) superconducting transformer system for the high current test of superconducting cables. The transformer consists of a core-free 10 464 turn primary solenoid which is enclosed by a 6.5 turn secondary. The transformer is designed to deliver a 50 kA dc secondary current at a dc primary current of about 50 A. The secondary current is measured inductively using two toroidal-wound Rogowski coils. The Rogowski coil signal is digitally integrated, resulting in a voltage signal that is proportional to the secondary current. This voltage signal is used to control the secondary current using a feedback loop which automatically compensates for resistive losses in the splices to the superconducting cable samples that are connected to the secondary. The system has been commissioned up to 28 kA secondary current. The reproducibility in the secondary current measurement is better than 0.05% for the relevant current range up to 25 kA. The drift in the secondary current, which results from drift in the digital integrator, is estimated to be below 0.5 A/min. The system's performance is further demonstrated through a voltage-current measurement on a superconducting cable sample at 11 T background magnetic field. The superconducting transformer system enables fast, high resolution, economic, and safe tests of the critical current of superconducting cable samples.

43 PARTICLE ACCELERATORS↗

Advanced analysis of laser-driven pulsed magnetic diffusion based on quantum molecular dynamics simulation

Magnetic diffusion plays an important role in inertial confinement fusion with strong magnetic fields. In this paper, we improve a previous analysis of the generation and diffusion of the magnetic field [Morita et al., Phys. Plasmas 25, 094505 (2018)]. For the generation process, we calculate the temporal evolution of the coil current using a self-consistent circuit model. The results show that the peak of the calculated magnetic field is delayed by 1.2 ns compared with that of the incident laser pulse. For the diffusion process, we evaluate the electrical conductivity of warm dense gold over a wide temperature range (300 K–100 eV) by combining the Kubo–Greenwood formula based on a quantum molecular dynamics simulation with the modified Spitzer model. Our simulation shows that the maximum magnetic field (530 T) that penetrates the cone is delayed by 2.5 ns compared with the laser peak. This result is consistent with experiments [Sakata et al., Nat. Commun. 9, 3937 (2018)] that showed that applying a strong magnetic field improved the heating efficiency of fusion fuel.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Monolithically integrated Helmholtz coils by 3-dimensional printing

3D printing technology is of great interest for the monolithic fabrication of integrated systems; however, it is a challenge to introduce metallic components into 3D printed molds to enable broader device functionality. Here, we develop a technique for constructing a multi-axial Helmholtz coil by injecting a eutectic liquid metal Gallium Indium alloy (EGaIn) into helically shaped orthogonal cavities constructed in a 3D printed block. The tri-axial solenoids each carry up to 3.6 A of electrical current and produce magnetic field up to 70 G. Within the central section of the coil, the field variation is less than 1% and is in agreement with theory. The flow rates and critical pressures required to fill the 3D cavities with liquid metal also agree with theoretical predictions and provide scaling trends for filling the 3D printed parts. These monolithically integrated solenoids may find future applications in electronic cell culture platforms, atomic traps, and miniaturized chemical analysis systems based on nuclear magnetic resonance.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

ORBUMP Pulsed Dipole Magnet Design for Fermilab Booster

Fermilab initiated the accelerator magnet system upgrade project PIP-II for future neutrino experiments. Old ORBUMP pulsed dipoles should be replaced with new stronger magnets occupying the same space as old ones. Four of these magnets connected in series form dogleg type of proton beam orbit. The magnet field and 19 kA current pulse length are close to 1 ms. Old magnet cores were based on a ferrite material. For new magnets, a magnet gap field is above 0.4 T, which completely saturates ferrite material. So, for the magnet core, 0.127 mm thick laminations of low carbon steel with inorganic coating, as the magnet were placed in a vacuum box. There were investigated transient magnet parameters including skin effect in the iron core and in the single-turn copper coil. The integrated field homogeneity was improved by the copper coil shimming. Simulated by OPERA3D power losses were used for the thermal analysis by ANSYS code. The magnet performance is strongly coupled with the power source. The dynamic magnet inductance and resistance were included in the pulsed power source design. Finally, the paper presented the ORBUMP magnet system design.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The Mu2e Solenoid Cold Mass Position Monitor System

The Mu2e experiment at Fermilab is designed to search for charged-lepton flavor violation by looking for muon to electron conversions in the field of the nucleus. The concept of the experiment is to generate a low momentum muon beam, stopping the muons in a target and measuring the momentum of the outgoing electrons. The implementation of this approach utilizes a complex magnetic field composed of graded solenoidal and toroidal fields. The location of the solenoid cold mass relative to external fiducials is needed for alignment as well as monitoring coil movements during cool down and magnet excitation. This study describes a novel design of a Cold Mass Position Monitor System (CMPS) that will be implemented for the Mu2e experiment.

43 PARTICLE ACCELERATORS↗

W7-X magnetic diagnostics: Rogowski coil performance for very long pulses

Stellerators can be operated without the need of significant plasma current for generation of poloidal magnetic field components. Wendelstein 7-X (W7-X) is optimized for stiff magnetic configurations by minimizing pressure driven currents, such as bootstrap and Pfirsch-Schlueter currents. In Addition to the largely reduced plasma currents, the HELIAS-type device is a low magnetic shear configuration required for magnetic boundary islands. However, the diverting magnetic field structure is already influenced by small net plasma currents. In particular, the W7-AS divertor results revealed a significant sensitivity of the X-point location with respect to favorable edge plasma states. Thus, a precise X-point control for W7-X is envisaged and, although expected net plasma currents range in the order of 10-100 kA only, stabilization by adaptive controllers is foreseen to an accuracy of about 1 kA. This stabilization should be reliable even after 2000 s of plasma operation. A precondition for achieving this is a reliable current detection. For this purpose, W7-X will be equipped with Rogowski of which the first has now been assembled onto one of the plasma vessel sectors. The integral performance and sensitivity inhomogeneities have been tested by employing the digital integrator of W7-X [A. Werner, Rev. Sci. Instrum. 77, 10E307 (2006)] and a cable energized with 200 A, representing the plasma current.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Fielding the magnetically applied pressure-shear technique on the Z accelerator (completion report for MRT 4519).

The recently developed Magnetically Applied Pressure-Shear (MAPS) experimental technique to measure material shear strength at high pressures on magneto-hydrodynamic (MHD) drive pulsed power platforms was fielded on August 16, 2013 on shot Z2544 utilizing hardware set A0283A. Several technical and engineering challenges were overcome in the process leading to the attempt to measure the dynamic strength of NNSA Ta at 50 GPa. The MAPS technique relies on the ability to apply an external magnetic field properly aligned and time correlated with the MHD pulse. The load design had to be modified to accommodate the external field coils and additional support was required to manage stresses from the pulsed magnets. Further, this represents the first time transverse velocity interferometry has been applied to diagnose a shot at Z. All subsystems performed well with only minor issues related to the new feed design which can be easily addressed by modifying the current pulse shape. Despite the success of each new component, the experiment failed to measure strength in the samples due to spallation failure, most likely in the diamond anvils. To address this issue, hydrocode simulations are being used to evaluate a modified design using LiF windows to minimize tension in the diamond and prevent spall. Another option to eliminate the diamond material from the experiment is also being investigated.

Alexander, C. Scott↗

Extending the operational boundaries of RMP-ELM suppression with optimized 3D field control

The use of 3D magnetic fields is one of the promising approaches to control edge localized modes (ELMs), and ITER has plans to utilize a flexible 3D coil set for ELM suppression using 3D fields. This study focuses on optimizing the 3D field spectrum to expand the operational window for n = 1 resonant magnetic perturbation (RMP) ELM suppression in KSTAR. The optimized n = 1 RMP effectively suppresses ELMs throughout the entire H-mode discharge, including the first ELM crash, while avoiding the onset of disruptive locked modes in low-density L-mode plasmas. The predicted suppression window aligns well with experimental data, highlighting the challenges and solutions of using n = 1 RMP at low densities. Moreover, the optimization successfully achieved n = 1 RMP ELM suppression for the first time in ITER-relevant q 95 and shaping conditions, including cases with q95 as low as 3.6, as well as other q 95 and shape configurations. This highlights the importance and utility of 3D coil optimization while emphasizing the potential of long-wavelength low-n RMP, which will be valuable for ex-vessel coils designed to avoid complications of nuclear degradation.

3D magnetic field control↗

Megagauss-level magnetic field production in cm-scale auto-magnetizing helical liners pulsed to 500 kA in 125 ns

We present Auto-magnetizing (AutoMag) liners [Slutz et al., Phys. Plasmas 24, 012704 (2017)] are designed to generate up to 100 T of axial magnetic field in the fuel for Magnetized Liner Inertial Fusion [Slutz et al., Phys. Plasmas 17, 056303 (2010)] without the need for external field coils. AutoMag liners (cylindrical tubes) are composed of discrete metallic helical conduction paths separated by electrically insulating material. Initially, helical current in the AutoMag liner produces internal axial magnetic field during a long (100 to 300 ns) current prepulse with an average current rise rate dI/dt=5 kA/ns. After the cold fuel is magnetized, a rapidly rising current (200 kA/ns) generates a calculated electric field of 64 MV/m between the helices. Such field is sufficient to force dielectric breakdown of the insulating material after which liner current is reoriented from helical to predominantly axial which ceases the AutoMag axial magnetic field production mechanism and the z-pinch liner implodes. Proof of concept experiments have been executed on the Mykonos linear transformer driver to measure the axial field produced by a variety of AutoMag liners and to evaluate what physical processes drive dielectric breakdown. Lastly, a range of field strengths have been generated in various cm-scale liners in agreement with magnetic transient simulations including a measured field above 90 T at I = 350 kA. By varying the helical pitch angle, insulator material, and insulator geometry, favorable liner designs have been identified for which breakdown occurs under predictable and reproducible field conditions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Magnetic Resonance Imaging Protocol Optimization for Delineation of Gross Tumor Volume in Hypopharyngeal and Laryngeal Tumors

Purpose: To optimize the use of MRI for delineation of gross tumor volume for radiotherapy treatment planning purposes in hypopharyngeal and laryngeal tumors. Methods and Materials: Magnetic resonance images (T1 weighted and T2 weighted) of a healthy volunteer were acquired using a 1.5 T and 3.0 T MR scanner. Various receiver coils were investigated that were compatible with the immobilization mask needed for reliable coregistration with computed tomography data. For the optimal receiver coil, the influence of resolution, slice thickness, and strength of magnetic field on the signal-to-noise ratio (SNR) was studied. Feasibility of the definitive protocol was tested on patients with hypopharyngeal (n = 19) and laryngeal (n = 42) carcinoma. Results: Large differences in SNR were obtained for the various coils. The SNR values obtained using surface coils that were compatible with the immobilization mask were three times higher than those obtained using a standard head-and-neck coil and five times higher than those obtained using a body coil. High-resolution images (0.4 x 0.4 x 4 mm{sup 3}) showed superior anatomic detail and resulted in a 4-min scan time. Image quality at 3.0 T was not significantly better compared with 1.5 T. In 3 patients the MR study could not be performed; for 5 patients images were severely deteriorated by motion artefacts. High-quality MR images were obtained in 53 patients. Conclusions: High-resolution MR images of the hypopharynx and larynx can be obtained in the majority of patients using surface receiver coils in combination with the radiotherapy mask. These MR images can be successfully used for tumor delineation in radiotherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Test Results for HINS Focusing Solenoids at Fermilab

A focusing lens R&D program is close to completion and industrial production of magnets has begun. Two types of magnets are being built for use in the room temperature RF section at the front end of a superconducting H-minus linac of a High Intensity Neutrino Source. All of the magnets are designed as a solenoid with bucking coils to cancel the field in the vicinity of adjacent RF cavities, and one type incorporates steering dipole corrector coils. We present a summary of the predicted and measured quench and magnetic properties for both R&D and production device samples that have been tested at Fermilab.

43 PARTICLE ACCELERATORS↗