Search NASA⌕ Search

SEARCH · Search NASA

Results for “MULTIPLICITY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Multiple myeloma cells adapted to long-exposure of hypoxia exhibit stem cell characters with TGF-β/Smad pathway activation

Highlights: • Hypoxia-adapted multiple myeloma cells exhibit stem cell characteristics. • Hypoxia-adapted multiple myeloma cells show higher tumorigenicity in vivo. • TGF-β/Smad pathway is critical for self-renewal for hypoxia-adapted myeloma cells. The emergence of new molecular targeting agents has improved the prognosis of patients with multiple myeloma (MM). However, MM remains incurable because MM stem cells are likely resistant to these agents. Thus, it is important to further investigate the biology of MM stem cells, which reside in the hypoxic bone marrow niche. In this study, we established and investigated the characteristics of hypoxia-adapted MM (HA-MM) cells, which could proliferate for more than six months under hypoxic conditions (1% O{sub 2}). The G0 fraction of HA-MM cells was larger than that of parental MM cells under normoxic conditions (20% O{sub 2}). HA-MM cells possess enhanced tumorigenicity in primary and secondary transplantation studies. HA-MM cells also exhibited increased mRNA levels of stem cell markers and an enhanced self-renewal ability, and thus demonstrated characteristics of MM stem cells. These cells overexpressed phosphorylated Smad2, and treatment with a transforming growth factor (TGF)-β/Smad signaling inhibitor decreased their clonogenicity in a replating assay. In conclusion, MM cells adapted to long-exposure of hypoxia exhibit stem cell characters with TGF-β/Smad pathway activation.

60 APPLIED LIFE SCIENCES↗

Ignition of turbulent swirling n-heptane spray flames using single and multiple sparks

This paper examines ignition processes of an n-heptane spray in a flow typical of a liquid-fuelled burner. The spray is created by a hollow-cone pressure atomiser placed in the centre of a bluff body, around which swirling air induces a strong recirculation zone. Ignition was achieved by single small sparks of short duration (2 mm; 0.5 ms), located at various places inside the flow so as to identify the most ignitable regions, or larger sparks of longer duration (5 mm; 8 ms) repeated at 100 Hz, located close to the combustion chamber enclosure so as to mimic the placement and characteristics of a gas turbine combustor surface igniter. The air and droplet velocities, the droplet diameter, and the total (i.e. liquid plus vapour) equivalence ratio were measured in inert flow by phase Doppler anemometry and sampling respectively. Fast camera imaging suggested that successful ignition events were associated with flamelets that propagated back towards the spray nozzle. Measurements of ignition probability with the single spark showed that localised ignition inside the spray is more likely to result in successful flame establishment when the spark is located in a region of negative velocity, relatively small droplet Sauter mean diameter, and mean equivalence ratio within the flammability limits. Ignition with the single spark was not possible at the location where the multiple spark experiments were performed. For those, the multiple spark sequence lasted approximately 1 to 5 s. It was found that a long spark sequence increases the ignition efficiency, which reached a maximum of 100% at the axial distance where the recirculation zone had maximum width. Ignition was not feasible with the spark downstream of about two burner diameters. Visualisation showed that small flame kernels emanate very often from the spark, which can be stretched as far as 20 mm from the electrodes by the turbulent velocity fluctuations. These kernels survive very little time. Successful overall ignition occurs at a random time from the spark initiation and, as in the case of the single spark, success is associated with kernels that move without getting extinguished towards the bluff body. The results demonstrate that the energy deposited by multiple sparks and spark stretching in a turbulent flow can have a spatially far-reaching effect to initiate combustion. (author)

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Multiple uses of indicators and indices in cumulative effects assessment and management

Both environmental indicators and multi-metric indices are useful for describing baseline conditions and qualitatively predicting the cumulative consequences of multiple actions. Several examples and case studies associated with indicators and/or indices are presented herein. They can be easily modified for usage in CEAM. Habitat suitability models reflect special indices related to habitat needs and quality for specific species or broad habitat types. Such models have been used to address direct and indirect effects, and with some modification, they can be also used to address cumulative effects of multiple actions. This review has indicated that there are numerous examples of such tools which have been or could be used in both EIA and CEAM. Some key lessons are: (1) in conducting CEAM studies, it is useful to think from the mindset that 'I am the VEC or indicator, and what is my historical and current condition and how have I, or will I, be affected by multiple past, present, and future actions?'; (2) due to the likely absence of detailed information on future actions, the described tools can still be used to 'predict' future conditions by focusing on qualitative up-or-down changes in individual indicators or indices with their aggregated displays; and (3) numerous regional and site-specific tools are currently available, with one example being indices of biological integrity for specific watersheds and water bodies. Such tools, even though they may not have been developed for CEAM usage, can certainly benefit CEAM studies and practice. Finally, usage of selected and appropriate tools as described herein can aid in conducting science-based, systematic, and documentable CEAM studies.

54 ENVIRONMENTAL SCIENCES↗

Effects of multiple simultaneous faults on characteristic fault detection features of a heat pump in cooling mode

Faults in air-cooled vapor compression air-conditioning systems are known to reduce performance, including efficiency, capacity, and lifespan. Their effects have been studied, and fault detection and diagnostic (FDD) methods have been developed as tools for field technicians to install or repair systems, or for monitoring to alert operators to the fault’s presence. Most of this work has focused on faults that occur singly. It is likely that in some systems, multiple faults occur simultaneously, but it is uncertain what effects this may have on diagnostics. Here, this paper describes a laboratory study of a split system air source heat pump in which combinations of two, three, and four simultaneous faults occur. The study includes all combinations of: improper evaporator airflow; overcharge or undercharge of refrigerant; liquid line restrictions; and non-condensable gas in the refrigerant, each at multiple fault intensities. Fault features – those characteristics that can be determined from measurements, for use in diagnostics – are analyzed, and the key fault features are presented. A robust existing method for determining refrigerant charge, the virtual refrigerant charge sensor (VRC) is tested using the multiple fault data, in order to understand how its performance is impacted by the combined faults. The VRC performs well, typically able to correctly determine whether a system is undercharged or overcharged, but the magnitude estimates are impacted. The results suggest that simple subcooling-based methods of charging a system are likely to provide unsatisfactory results when other faults are present.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Early Clinical Experience and Outcome of Helical Tomotherapy for Multiple Metastatic Lesions

Purpose: To evaluate the feasibility of synchronous treatment of multiple metastatic lesions by helical tomotherapy. Methods and Materials: Forty-two patients with multiple metastatic lesions were treated by helical tomotherapy from April 2006 to February 2007. Among these patients, 21 had metastatic bone disease. Subjective pain response was assessed using the visual analogue scales, and morbidity was evaluated by Common Terminology Criteria for Adverse Events v3.0. The correlation between the percentage of red bone marrow in the radiation field and the severity of leukocytopenia was analyzed. Results: The median age was 57 years. Radiation dose to the gross tumor volume was 30-84 Gy, with a median fractional size of 3 Gy. Mean treatment time was 16 min and 1 sec. Treatment time and fraction size were modified because of poor performance status or hematologic toxicity in two patients. With regard to palliative effects for bone metastasis, 16 patients (76.2%) experienced positive pain relief. Four patients had Grade III leukocytopenia, and three had Grade IV leukocytopenia. In the multivariate logistic regression, red marrow percentage was the independent risk factor most associated with Grade III/IV leukocytopenia (p = 0.014). The tolerance cutoff point of red bone marrow was 26.8%, with a sensitivity and specificity of 85.7% and 85.7%, respectively. Conclusions: Helical tomotherapy was effective for symptom palliation and was feasible for patients with multiple metastatic diseases. The volume of red bone marrow, as well as performance status, must be taken into account to determine optimal treatment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Treatment Results of Postoperative Radiotherapy on Squamous Cell Carcinoma of the Oral Cavity: Coexistence of Multiple Minor Risk Factors Results in Higher Recurrence Rates

Purpose: The aim of this study was to investigate the treatment results of postoperative radiotherapy (PORT) on squamous cell carcinoma of the oral cavity (OSCC). Materials and Methods: This study included 302 OSCC patients who were treated by radical surgery and PORT. Indications for PORT include Stage III or IV OSCC according to the 2002 criteria of the American Joint Committee on Cancer, the presence of perineural invasion or lymphatic invasion, the depth of tumor invasion, or a close surgical margin. Patients with major risk factors, such as multiple nodal metastases, a positive surgical margin, or extracapsular spreading, were excluded. The prescribed dose of PORT ranged from 59.4 to 66.6Gy (median, 63Gy). Results: The 3-year overall and recurrence-free survival rates were 73% and 70%, respectively. Univariate analysis revealed that differentiation, perineural invasion, lymphatic invasion, bone invasion, location (hard palate and retromolar trigone), invasion depths {>=}10mm, and margin distances {<=}4mm were significant prognostic factors. The presence of multiple significant factors of univariate analysis correlated with disease recurrence. The 3-year recurrence-free survival rates were 82%, 76%, and 45% for patients with no risk factors, one or two risk factors, and three or more risk factors, respectively. After multivariate analysis, the number of risk factors and lymphatic invasion were significant prognostic factors. Conclusion: PORT may be an adequate adjuvant therapy for OSCC patients with one or two risk factors of recurrence. The presence of multiple risk factors and lymphatic invasion correlated with poor prognosis, and more aggressive treatment may need to be considered.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

2-Methoxyestradiol, an Endogenous Estrogen Metabolite, Sensitizes Radioresistant MCF-7/FIR Breast Cancer Cells Through Multiple Mechanisms

Purpose: The requirement for a well-tolerated and highly effective radiosensitizer that preferentially sensitizes tumor cells at multiple levels of radioresistance remains largely unmet. 2-Methoxyestradiol (2ME) has polypharmacological profiles that target multiple signaling pathways involved in the development of radioresistance. In the current study, we investigated the radiosensitizing effect of 2ME on the radioresistant breast cancer MCF-7/FIR cell line and explored the underlying mechanisms. Methods and Materials: The radiosensitizing effect of 2ME was evaluated on the basis of cell death and clonogenic survival. Formation of reactive oxygen species (ROS), apoptosis, and cell cycle progression were assessed by flow cytometry. Radiation-induced DNA damage was evaluated on the basis of histone {gamma}-H2AX phosphorylation and foci formation. Immunoblotting was used to assess the effects of {gamma} radiation and/or 2ME on radioresistance pathways. Results: Our data demonstrate that MCF-7/FIR cells expressed higher levels of Bcl-2 and HIF-1{alpha} and displayed a lower ROS phenotype than the parental MCF-7 cells. Treatment of parental MCF-7 cells with 2ME (0.5 {mu}M) had minimal effect on {gamma} radiation-induced cell proliferation and surviving fractions. On the contrary, in MCF-7/FIR cells, treatment with 2ME significantly enhanced {gamma} radiation-induced reduction in cell proliferation and surviving fraction. This combination was effective in activating apoptosis, arresting the cell cycle at the G{sub 2}/M phase, and increasing the level of {gamma} radiation-induced ROS and the number of {gamma}-H2AX foci. In addition, 2ME significantly ameliorated {gamma} radiation-induced expression of the HIF-1{alpha} transcription factor and its downstream targets AKT/mTOR. Conclusion: 2ME preferentially sensitizes radioresistant MCF-7/FIR cells to {gamma} radiation by targeting multiple signaling pathways involved in the development of radioresistance. This polypharmacological profile qualifies 2ME as a promising radiosensitizer in the treatment of radioresistant breast cancer cells and warrants systematic preclinical and clinical studies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Simple and Efficient Methodology To Improve Geometric Accuracy in Gamma Knife Radiation Surgery: Implementation in Multiple Brain Metastases

Purpose: To propose, verify, and implement a simple and efficient methodology for the improvement of total geometric accuracy in multiple brain metastases gamma knife (GK) radiation surgery. Methods and Materials: The proposed methodology exploits the directional dependence of magnetic resonance imaging (MRI)-related spatial distortions stemming from background field inhomogeneities, also known as sequence-dependent distortions, with respect to the read-gradient polarity during MRI acquisition. First, an extra MRI pulse sequence is acquired with the same imaging parameters as those used for routine patient imaging, aside from a reversal in the read-gradient polarity. Then, “average” image data are compounded from data acquired from the 2 MRI sequences and are used for treatment planning purposes. The method was applied and verified in a polymer gel phantom irradiated with multiple shots in an extended region of the GK stereotactic space. Its clinical impact in dose delivery accuracy was assessed in 15 patients with a total of 96 relatively small (<2 cm) metastases treated with GK radiation surgery. Results: Phantom study results showed that use of average MR images eliminates the effect of sequence-dependent distortions, leading to a total spatial uncertainty of less than 0.3 mm, attributed mainly to gradient nonlinearities. In brain metastases patients, non-eliminated sequence-dependent distortions lead to target localization uncertainties of up to 1.3 mm (mean: 0.51 ± 0.37 mm) with respect to the corresponding target locations in the “average” MRI series. Due to these uncertainties, a considerable underdosage (5%-32% of the prescription dose) was found in 33% of the studied targets. Conclusions: The proposed methodology is simple and straightforward in its implementation. Regarding multiple brain metastases applications, the suggested approach may substantially improve total GK dose delivery accuracy in smaller, outlying targets.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Influence of alveolar mixing and multiple breaths of aerosol intake on particle deposition in the human lungs

Predictive dosimetry models play an important role in assessing health effect of inhaled particulate matter and in optimizing delivery of inhaled pharmaceutical aerosols. Here, in this study, the commonly used 1D Multiple-Path Particle Dosimetry model (MPPD) was improved by including a mechanistically based model component for alveolar mixing of particles and by extending the model capabilities to account for multiple breaths of aerosol intake. These modifications increased the retained fraction of particles and consequently particle deposition predictions in the deep lung during tidal breathing. Comparison with an existing dataset (J. Aerosol Sci., 99:27-39, 2016) obtained under two breathing conditions referred to as slow and fast breathing showed significant differences in 1 µm particle deposition between predictions (slow: 30±1%, fast: 21±1%) and measurements (slow: 43±9%, fast: 30±5%) when the prior version of MPPD (single breath and no mixing, J. Aerosol Sci., 151:105647, 2021) was used. Adding a mixing model and multiple breaths moved the predictions (slow: 34±2%, fast:25±2%) closer to the range of deposition measurements. For 2.9 µm particles, predictions from both the original (slow: 70±2%, fast: 57±2%) and the revised MPPD model (slow: 71±2%, fast: 59±3%) compared well with experiments (slow: 67±8%, fast: 58±10%). This was expected as suspended fraction of 2.9 µm particles was small and thus the addition of alveolar mixing and multi breath capability only slightly increased the retained fraction for particles of this size and greater. The revised 1D model improves dose predictions in the deep lung and support human risk assessment from exposure to airborne particles.

60 APPLIED LIFE SCIENCES↗

Hybrid approaches for multiple-species stochastic reaction–diffusion models

Reaction–diffusion models are used to describe systems in fields as diverse as physics, chemistry, ecology and biology. The fundamental quantities in such models are individual entities such as atoms and molecules, bacteria, cells or animals, which move and/or react in a stochastic manner. If the number of entities is large, accounting for each individual is inefficient, and often partial differential equation (PDE) models are used in which the stochastic behaviour of individuals is replaced by a description of the averaged, or mean behaviour of the system. In some situations the number of individuals is large in certain regions and small in others. In such cases, a stochastic model may be inefficient in one region, and a PDE model inaccurate in another. To overcome this problem, we develop a scheme which couples a stochastic reaction–diffusion system in one part of the domain with its mean field analogue, i.e. a discretised PDE model, in the other part of the domain. The interface in between the two domains occupies exactly one lattice site and is chosen such that the mean field description is still accurate there. In this way errors due to the flux between the domains are small. Our scheme can account for multiple dynamic interfaces separating multiple stochastic and deterministic domains, and the coupling between the domains conserves the total number of particles. The method preserves stochastic features such as extinction not observable in the mean field description, and is significantly faster to simulate on a computer than the pure stochastic model. - Highlights: • A novel hybrid stochastic/deterministic reaction–diffusion simulation method is given. • Can massively speed up stochastic simulations while preserving stochastic effects. • Can handle multiple reacting species. • Can handle moving boundaries.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Projected network performance for multiple isotopes using next-generation xenon monitoring systems

Since about 2000 (Bowyer et al., 1998), radioxenon monitoring systems have been under development and testing for the verification of the Comprehensive Nuclear Test-Ban Treaty (CTBT). Operation of the systems since then has resulted in development of a next-generation of systems that are nearly ready for operational deployment. By 2010, the need to screen out civilian sources was well known (Auer et al., 2010; Saey, 2009), and isotopic ratio approaches were soon considered (Kalinowski et al., 2014) to identify specific sources. New generation systems are expected to improve the ability to verify the absence of nuclear tests by using isotopic ratios when multiple isotopes are detected. In this work, thousands of releases were simulated to compute the global detection probability of 131m Xe, 133m Xe, 133 Xe, and 135 Xe at 39 noble gas systems in the International Monitoring System (IMS) for both current and next-generation systems. Three release scenarios are defined at 1 h, 1 d, and 10 d past a 1 kt TNT equivalent 235U explosion event. Multiple cases using from one part in a million to the complete release of the xenon isotopic activity are evaluated for each scenario. Coverage maps and global integrals comparing current and next-generation monitoring systems are presented showing that next-generation noble gas systems will create measurable improvements in the IMS. The global detection probability for 133 Xe is shown to be strong in all scenarios, but only modestly improved by next-generation equipment. However, the detection probability for 131m Xe and 133m Xe increased to about 50% in different scenarios, providing a second detectable isotope for many events. As anticipated from shorter sampling intervals, the expected number of detecting samples roughly doubled and the expected number of detecting stations rose by approximately 50% for all release scenarios. Thus, it might be anticipated that future events would consist of multiple 133 Xe detections and one or more second isotope detections. In conclusion, signals of this nature should increase detection confidence, tighten release location estimates, improve rejection of civilian signals, and lessen the impacts from individual systems being offline for maintenance or repair reasons.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Is a single isocenter sufficient for volumetric modulated arc therapy radiosurgery when multiple intracranial metastases are spatially dispersed?

Previous work demonstrated improved dosimetry of single isocenter volumetric modulated arc therapy (VMAT) of multiple intracranial targets when they are located ≤ 4 cm from isocenter because of narrower multileaf collimators (MLCs). In follow-up, we sought to determine if decreasing isocenter-target distance (d{sub iso}) by using 2 to 3 isocenters would improve dosimetry for spatially dispersed targets. We also investigated the effect of a maximum dose constraint during VMAT optimization, and the dosimetric effect of the number of VMAT arcs used for a larger number of targets (i.e., 7 to 9). We identified radiosurgery cases that had multiple intracranial targets with d{sub iso} of at least 1 target > 5 cm. A single isocenter VMAT plan was created using a standardized 4-arc technique with 18 Gy per target. Each case was then replanned (1) using 2 to 3 isocenters, (2) including a maximum dose constraint per target, and in the case of 7 to 9 targets, (3) using 3 to 6 arcs. Dose evaluation included brain V{sub 6} {sub Gy} and V{sub 12} {sub Gy}, and conformity index (CI), gradient index (GI), and heterogeneity index (HI) per target. Two isocenters were sufficient to limit d{sub iso} to ≤ 4 cm and ≤ 5 cm for 11/15 and 13/15 cases, respectively; after replanning with 2 to 3 isocenters, d{sub iso} decreased from 5.8 ± 2.8 cm (2.3 14.9) to 2.5 ± 1.4 cm (0 5.2). All dose statistics improved on average, albeit modestly: V{sub 6} {sub Gy} = 6.9 ± 7.1%, V{sub 12} {sub Gy} = 0.9% ± 4.4%, CI = 2.6% ± 4.6%, GI = 0.9% ± 12.7%, and HI = 2.6% ± 5.2%; however, the number of arcs doubled and monitor units increase by nearly 2-fold. A maximum dose constraint had a negative effect on all dose indices, increasing V{sub 12} {sub Gy} by 9.7 ± 6.9%. For ≥ 7 targets, increasing number of arcs to > 3 improved CI, V{sub 12} {sub Gy}, and V{sub 6} {sub Gy}. A single isocenter is likely sufficient for VMAT radiosurgery of multiple intracranial metastases. Optimal treatment plan quality is achieved when no constraint is placed on the maximum target dose; for cases with many targets at least 4 arcs are needed for optimal plan quality.

61 RADIATION PROTECTION AND DOSIMETRY↗

Plan quality comparison between 4-arc and 6-arc noncoplanar volumetric modulated arc stereotactic radiotherapy for the treatment of multiple brain metastases

To compare the plans of 4-arc and 6-arc noncoplanar volumetric modulated arc stereotactic radiotherapy (VMA-SRT) for multiple brain metastases and to investigate the cutoff value for the tumor number and volume for 6-arc rather than 4-arc VMA-SRT. We identified 24 consecutive multiple-target cases (3 to 19 targets in each case) with 189 total targets. We constructed plans using both 4- and 6-arc noncoplanar VMA-SRT. The prescribed dose was 36 Gy/6 fr, and it was delivered to 95% of the planning target volume (PTV). The plans were evaluated for the dose conformity using the Radiation Therapy Oncology Group and Paddick conformity indices (RCI and PCI), fall-off (Paddick gradient index [PGI]), and the normal brain dose. The median (range) RCI, PCI, and PGI was 0.94 (0.92 to 0.99), 0.89 (0.77 to 0.94), and 3.75 (2.24 to 6.54) for the 4-arc plan and 0.94 (0.91 to 0.98), 0.89 (0.76 to 0.94), and 3.65 (2.24 to 6.5) for the 6-arc plan, respectively. The median (range) of the normal brain dose was 910.3 cGy (381.4 to 1268.9) for the 4-arc plan and 898.8 cGy (377 to 1252.9) for the 6-arc plan. The PGI of the 6-arc plan was significantly superior to that of the 4-arc plan (p = 0.0076), and the optimal cutoff values for the tumor number and volume indicative of 6-arc (and not 4-arc) VMA-SRT were cases with ≥ 5 metastases and a PTV of ≥ 12.9 mL, respectively. The PCI values, however, showed no significant difference between the 2 plans. We believe these results will help in considering the use of 6-arc VMA-SRT for multiple brain metastases.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Multiplication and Presence of Shielding Material from Time-Correlated Pulse-Height Measurements of Subcritical Plutonium Assemblies

Here, we present the results from the first measurements of the Time-Correlated Pulse-Height (TCPH) distributions from 4.5 kg sphere of α-phase weapons-grade plutonium metal in five configurations: bare, reflected by 1.27 cm and 2.54 cm of tungsten, and 2.54 cm and 7.62 cm of polyethylene. A new method for characterizing source multiplication and shielding configuration is also demonstrated. The method relies on solving for the underlying fission chain timing distribution that drives the spreading of the measured TCPH distribution. We found that a gamma distribution fits the fission chain timing distribution well and that the fit parameters correlate with both multiplication (rate parameter) and shielding material types (shape parameter). The source-to-detector distance was another free parameter that we were able to optimize, and proved to be the most well constrained parameter. MCNPX-PoliMi simulations were used to complement the measurements and help illustrate trends in these parameters and their relation to multiplication and the amount and type of material coupled to the subcritical assembly.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Multiplicity dependence of ϒ production at forward rapidity in pp collisions at $\sqrt{s}$ = 13 TeV

The measurement of ϒ(1S), ϒ(2S), and ϒ(3S) yields as a function of the charged-particle multiplicity density, d N ch /d η , using the ALICE experiment at the LHC, is reported in pp collisions at √s = 13 TeV. The Υ meson yields are measured at forward rapidity (2.5 < y < 4) in the dimuon decay channel, whereas the charged-particle multiplicity is defined at central rapidity (| η | <1). Both quantities are divided by their average value in minimum bias events to compute the self-normalized quantities. The increase of the self-normalized ϒ(1S), ϒ(2S), and ϒ(3S) yields is found to be compatible with a linear scaling with the self-normalized d N ch /d η , within the uncertainties. The self-normalized yield ratios of excited-to-ground ϒ states are compatible with unity within uncertainties. Similarly, the measured double ratio of the self-normalized ϒ(1S) to the self-normalized J/ ψ yields, both measured at forward rapidity, is compatible with unity for self-normalized charged-particle multiplicities beyond one. The measurements are compared with theoretical predictions incorporating initial or final state effects.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Centrality and pseudorapidity dependence of the charged-particle multiplicity density in Xe–Xe collisions at s NN = 5.44 TeV

In this Letter, the ALICE Collaboration presents the first measurements of the charged-particle multiplicity density, dN ch /dη and total charged-particle multiplicity, N$tot\atop{ch}$, in Xe–Xe collisions at a centre-of-mass energy per nucleon–nucleon pair of $ \sqrt{s_{NN}}$=5.44TeV. The measurements are performed as a function of collision centrality over a wide pseudorapidity range of -3.5<η<5. The values of dN ch /dη at mid-rapidity and N$tot\atop{ch}$ for central collisions, normalised to the number of nucleons participating in the collision (N part ) as a function of $ \sqrt{s_{NN}}$ follow the trends established in previous heavy-ion measurements. The same quantities are also found to increase as a function of Npart, and up to the 5% most central collisions the trends are the same as the ones observed in Pb–Pb at a similar energy. For more central collisions, the Xe–Xe scaled multiplicities exceed those in Pb–Pb for a similar N part . The results are compared to phenomenological models and theoretical calculations based on different mechanisms for particle production in nuclear collisions. All considered models describe the data reasonably well within 15%.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Accessing subnuclear fluctuations and saturation with multiplicity dependent J/ψ production in p+p and p+Pb collisions

We study the production of J/ψ vector mesons as a function of charged hadron multiplicity in p+p and p+Pb collisions at LHC energies. We employ the color glass condensate framework, using running coupling Balitsky-Kovchegov evolved dipole amplitudes, to compute gluon and cc¯-pair production. We use fragmentation functions to obtain charged hadrons, and explore two different hadronization schemes for the J/ψ: non-relativistic quantum chromodynamics and the improved color evaporation model. In our framework, event-by-event multiplicity fluctuations of both hadrons and J/ψ are driven by geometric and saturation scale normalization fluctuations. Studying the correlation between J/ψ and hadron multiplicity, we show that the characteristic difference between forward and backward rapidity in p+Pb collisions is a result of different degrees of saturation probed at different rapidities. We demonstrate that experimental data on heavy-flavor production as a function of event activity provide stringent constraints on the fluctuating proton structure

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Energy dependence of prompt fissions neutron multiplicity in the 239 Pu(n, ƒ) reaction

Accurate multiplicities of prompt fission neutrons emitted in neutron-induced fission on a large energy range are essential for fundamental and applied nuclear physics. Measuring them to high precision for radioactive fissioning nuclides remains, however, an experimental challenge. In this work, the average prompt-neutron multiplicity emitted in the 239 Pu(n, ƒ) reaction was extracted as a function of the incident-neutron energy, over the range 1-700 MeV, with a novel technique, which allowed to minimize and correct for the main sources of bias and thus achieve unprecedented precision. At low energies, our data validate for the first time the ENDF/B-VIII.0 nuclear data evaluation with an independent measurement and reduce the evaluated uncertainty by up to 60%. This work opens up the possibility of precisely measuring prompt fission neutron multiplicities on highly radioactive nuclei relevant for an essential component of energy production world-wide.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗