Search NASA⌕ Search

SEARCH · Search NASA

Results for “Measurement Optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Design of Digital Twin Sensing Strategies Via Predictive Modeling and Interpretable Machine Learning

This work develops a methodology for sensor placement and dynamic sensor scheduling decisions for digital twins. The digital twin data assimilation is posed as a classification problem, and predictive models are used to train optimal classification trees that represent the map from observed data to estimated digital twin states. In addition to providing a rapid digital twin updating capability, the resulting classification trees yield an interpretable mathematical representation that can be queried to inform sensor placement and sensor scheduling decisions. The proposed approach is demonstrated for a structural digital twin of a 12 ft wingspan unmanned aerial vehicle. Offline, training data are generated by simulating scenarios using predictive reduced-order models of the vehicle in a range of structural states. Furthermore, these training data can be further augmented using experimental or other historical data. In operation, the trained classifier is applied to observational data from the physical vehicle, enabling rapid adaptation of the digital twin in response to changes in structural health. Within this context, we study the performance of the optimal tree classifiers and demonstrate how they enable explainable structural assessments from sparse sensor measurements and also inform optimal sensor placement.

47 OTHER INSTRUMENTATION↗

Propagation distance-resolved characteristics of filament-induced copper plasma

Copper plasma generated at different filament-copper interaction points was characterized by spectroscopic, acoustic, and imaging measurements. The longitudinal variation of the filament intensity was qualitatively determined by acoustic measurements in air. The maximum plasma temperature was measured at the location of peak filament intensity, corresponding to the maximum mean electron energy during plasma formation. The highest copper plasma density was measured past the location of the maximum electron density in the filament, where spectral broadening of the filament leads to enhanced ionization. Acoustic measurements in air and on solid target were correlated to reconstructed plasma properties. Lastly, optimal line emission is measured near the geometric focus of the lens used to produce the filament.

36 MATERIALS SCIENCE↗

Spectra, composition, and interactions of nuclei with magnet interaction chambers

Emulsion chambers will be flown in the Astromag Facility to measure the cosmic ray composition and spectra to 10 exp 15 eV total energy and to definitively study the characteristics of nucleus-nucleus interactions above 10 exp 12 eV/n. Two configurations of emulsion chambers will be flown in the SCIN/MAGIC experiment. One chamber has an emulsion target and a calorimeter similar to those recently flown on balloons for composition and spectra measurements. The other has an identical calorimeter and a low-density target section optimized for performing rigidity measurements on charged particles produced in interactions. The transverse momenta of charged and neutral mesons, direct hadronic pairs from resonance decays and interference effects, and possible charge clustering in high-density states of matter will be studied.

Parneil, T. A.↗

GLOW: The Goddard Lidar Observatory for Winds

GLOW (Goddard Lidar Observatory for Winds) is a mobile Doppler lidar system which uses direct detection Doppler lidar techniques to measure wind profiles from the surface into the lower stratosphere. The system is contained in a modified van to allow deployment in field operations. The lidar system uses a Nd:YAG laser transmitter to measure winds using either aerosol backscatter at 1064 nm or molecular backscatter at 355 nm. The receiver telescope is a 45 cm Dall-Kirkham which is fiber coupled to separate Doppler receivers, one optimized for the aerosol backscatter wind measurement and another optimized for the molecular backscatter wind measurement. The receivers are implementations of the 'double edge' technique and use high spectral resolution Fabry-Perot etalons to measure the Doppler shift. A 45 cm aperture azimuth-over-elevation scanner is mounted on the roof of the van to allow full sky access and a variety of scanning options. GLOW is intended to be used as a deployable field system for studying atmospheric dynamics and transport and can also serve as a testbed to evaluate candidate technologies developed for use in future spaceborne systems. In addition, it can be used for calibration/validation activities following launch of spaceborne wind lidar systems. A description of the mobile system is presented along with the examples of lidar wind profiles obtained with the system.

Gentry, Bruce M.↗

GLOW- The Goddard Lidar Observatory for Winds

GLOW (Goddard Lidar Observatory for Winds) is a mobile Doppler lidar system which uses direct detection Doppler lidar techniques to measure wind profiles from the surface into the lower stratosphere. The system is contained in a modified van to allow deployment in field operations. The lidar system uses a Nd:YAG laser transmitter to measure winds using either aerosol backscatter at 1064 nm or molecular backscatter at 355 nm. The receiver telescope is a 45 cm Dall-Kirkham which is fiber coupled to separate Doppler receivers, one optimized for the aerosol backscatter wind measurement and another optimized for the molecular backscatter wind measurement. The receivers are implementations of the 'double edge' technique and use high spectral resolution Fabry-Perot etalons to measure the Doppler shift. A 45 cm aperture azimuth-over-elevation scanner is mounted on the roof of the van to allow full sky access and a variety of scanning options. GLOW is intended to be used as a deployable field system for studying atmospheric dynamics and transport and can also serve as a testbed to evaluate candidate technologies developed for use in future spaceborne systems. In addition, it can be used for calibration/validation activities following launch of spaceborne wind lidar systems. A description of the mobile system is presented along with the examples of lidar wind profiles obtained with the system.

Gentry, Bruce M.↗

Identification of optimal solar fuel electrocatalysts via high throughput in situ optical measurements

For many solar fuel generator designs involve illumination of a photoabsorber stack coated with a catalyst for the oxygen evolution reaction (OER). In this design, impinging light must pass through the catalyst layer before reaching the photoabsorber(s), and thus optical transmission is an important function of the OER catalyst layer. Many oxide catalysts, such as those containing elements Ni and Co, form oxide or oxyhydroxide phases in alkaline solution at operational potentials that differ from the phases observed in ambient conditions. To characterize the transparency of such catalysts during OER operation, 1031 unique compositions containing the elements Ni, Co, Ce, La, and Fe were prepared by a high throughput inkjet printing technique. Moreover, the catalytic current of each composition was recorded at an OER overpotential of 0.33 V with simultaneous measurement of the spectral transmission. By combining the optical and catalytic properties, the combined catalyst efficiency was calculated to identify the optimal catalysts for solar fuel applications within the material library. Our measurements required development of a new high throughput instrument with integrated electrochemistry and spectroscopy measurements, which enables various spectroelectrochemistry experiments.

25 ENERGY STORAGE↗

Quantum-teleportation benchmarks for independent and identically distributed spin states and displaced thermal states

A successful state-transfer (or teleportation) experiment must perform better than the benchmark set by the 'best' measure and prepare procedure. We consider the benchmark problem for the following families of states: (i) displaced thermal equilibrium states of a given temperature; (ii) independent identically prepared qubits with a completely unknown state. For the first family we show that the optimal procedure is heterodyne measurement followed by the preparation of a coherent state. This procedure was known to be optimal for coherent states and for squeezed states with the 'overlap fidelity' as the figure of merit. Here, we prove its optimality with respect to the trace norm distance and supremum risk. For the second problem we consider n independent and identically distributed (i.i.d.) spin-(1/2) systems in an arbitrary unknown state {rho} and look for the measurement-preparation pair (M{sub n},P{sub n}) for which the reconstructed state {omega}{sub n}:=P{sub n} circle M{sub n}({rho}{sup xn}) is as close as possible to the input state (i.e., parallel {omega}{sub n}-{rho}{sup xn} parallel {sub 1} is small). The figure of merit is based on the trace norm distance between the input and output states. We show that asymptotically with n this problem is equivalent to the first one. The proof and construction of (M{sub n},P{sub n}) uses the theory of local asymptotic normality developed for state estimation which shows that i.i.d. quantum models can be approximated in a strong sense by quantum Gaussian models. The measurement part is identical to 'optimal estimation', showing that 'benchmarking' and estimation are closely related problems in the asymptotic set up.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Sequential Filtering in the Presence of Uniform Measurement Errors

This paper presents a sequential filtering strategy using observations corrupted with uniform measurement noise. While the Kalman filter remains the best linear estimator of the state, other filtering techniques provide minimum variance optimal estimates, a trait only enjoyed by the Kalman filter when the underlying noises are, in fact, Gaussian. This work develops a new approximate optimal estimator for uniform measurement noises. The resulting recursion requires just slightly more computational time to complete a measurement update than the Kalman filter, which generally cannot be claimed by other optimal strategies such as the particle or Gaussian mixture filters.

James S. McCabe↗

Sequential Filtering in the Presence of Uniform Measurement Errors

This paper presents a sequential filtering strategy using observations corrupted with uniform measurement noise. While the Kalman filter remains the best linear estimator of the state, other filtering techniques provide minimum variance optimal estimates, a trait only enjoyed by the Kalman filter when the underlying noises are, in fact, Gaussian. This work develops a new approximate optimal estimator for uniform measurement noises. The resulting recursion requires just slightly more computational time to complete a measurement update than the Kalman filter, which generally cannot be claimed by other optimal strategies such as the particle or Gaussian mixture filters.

James S McCabe↗

Uncertainty analysis of axial temperature and Seebeck coefficient measurements

Experimental investigations of solid materials at elevated temperatures rely on the optimized thermal design of the measurement system, as radiation becomes a predominant source of heat loss which can lead to large uncertainty in measured temperature and related physical properties of a test sample. Advancements in surface temperature measurements have reduced thermal losses arising from the cold-finger effect using axially inserted thermocouples and from radiation using shields or other thermal guards. The leading technology for temperature sensing at temperatures up to ~900 °C makes use of these design features for measuring thermopower, yet uncertainty analysis estimation of this technique is not known. This study makes use of finite element modeling to determine spatial temperature distributions to obtain the upper limit of confidence expected for the axially inserted thermocouple approach when a heated radiation shield is incorporated into the design. Using an axially inserted thermocouple to measure the sample surface temperature, the temperature variations across the sample hot and cold surfaces at 900 °C for a temperature drop of 0, 5, and 10 °C are calculated to be as low as 0.02, 0.21, and 0.41 °C, respectively, when a heated radiation shield is employed. Uniform temperature distribution on the thermocouple cross-wire geometry indicates that the axial thermocouple measurement design is indeed effective for suppressing the cold-finger effect. Using a heated radiation shield is found to significantly reduce the temperature gradient across the thermocouples.

30 DIRECT ENERGY CONVERSION↗

DESI DR1 Ly α 1D power spectrum: Validation of estimators

The Data Release 1 (DR1) of the Dark Energy Spectroscopic Instrument (DESI) is the largest sample to date for small-scale Lyα forest cosmology, accessed through its one-dimensional power spectrum (P 1D ). The Lyα forest P 1D is extracted from quasar spectra that are highly inhomogeneous (both in wavelength and between quasars) in noise properties due to intrinsic properties of the quasar, atmospheric and astrophysical contamination, and also sensitive to low-level details of the spectral extraction pipeline. We employ two estimators in DR1 analysis to measure P 1D : the optimal estimator and the fast Fourier transform (FFT) estimator. To ensure robustness of our DR1 measurements, we validate these two power spectrum and covariance matrix estimation methodologies against the challenging aspects of the data. First, using a set of 20 synthetic 1D realizations of DR1, we derive the masking bias corrections needed for the FFT estimator and the continuum fitting bias needed for both estimators. We demonstrate that both estimators, including their covariances, are unbiased with these corrections using the Kolmogorov-Smirnov test. Second, we substantially extend our previous suite of CCD image simulations to include 675,000 quasars, allowing us to accurately quantify the pipeline's performance. This set of simulations reveals biases at the highest k values, corresponding to a resolution error of a few percent. We base the resolution systematics error budget of DR1 P 1D on these values, but do not derive corrections from them since the simulation fidelity is insufficient for precise corrections.

Lyman alpha forest↗

Rapid measurement of RH-dependent aerosol hygroscopic growth using a humidity-controlled fast integrated mobility spectrometer (HFIMS)

Abstract. The ability of aerosol particles to uptake water (hygroscopic growth) is an important determinant of aerosol optical properties and radiative effects. Aerosol hygroscopic growth is traditionally measured by humidified tandem differential mobility analyzers (HTDMA), in which size-selected dry particles are exposed to elevated relative humidity (RH), and the size distribution of humidified particles is subsequently measured using a scanning mobility particle sizer. As a scanning mobility particle sizer can measure only one particle size at a time, HTDMA measurements are time consuming, and ambient measurements are often limited to a single RH level. Pinterich et al. (2017b) showed that fast measurements of aerosol hygroscopic growth are possible using a humidity-controlled fast integrated mobility spectrometer (HFIMS). In HFIMS, the size distribution of humidified particles is rapidly captured by a water-based fast integrated mobility spectrometer (WFIMS), leading to a factor of ∼10 increase in measurement time resolution. In this study we present a prototype HFIMS that extends fast hygroscopic growth measurements to a wide range of atmospherically relevant RH values, allowing for more comprehensive characterizations of aerosol hygroscopic growth. A dual-channel humidifier consisting of two humidity conditioners in parallel is employed such that aerosol RH can be quickly stepped among different RH levels by sampling from alternating conditioners. The measurement sequence is also optimized to minimize the transition time between different particle sizes. The HFIMS is capable of measuring aerosol hygroscopic growth of six particle diameters under five RH levels ranging from 20 % to 85 % (30 separate measurements) every 25 min. The performance of this HFIMS is characterized and validated using laboratory-generated ammonium sulfate aerosol standards. Measurements of ambient aerosols are shown to demonstrate the capability of HFIMS to capture the rapid evolution of aerosol hygroscopic growth and its dependence on both size and RH.

54 ENVIRONMENTAL SCIENCES↗

Global tropospheric and total ozone monitoring with a Double-Etalon Fabry-Perot interferometer

Knowledge of the global scale distribution of atmospheric ozone and its temporal variability can be achieved using a satellite-based nadir-viewing device making high spectral resolution measurements with high signal-to-noise ratios. This would enable observation in the pressure-broadened wings of strong O3 lines while minimizing the impact of undesirable signal contributions associated with, for example, the terrestrial surface and interfering species. The Fabry-Perot interferometer (FPI) provides high spectral resolution and high throughput capabilities that are essential for this measurement task. The periodic nature of the Fabry-Perot instrument function can be advantageous when observation of periodic spectra is desired. However, for most applications, additional optical elements are necessary to reduce the effect of unwanted passbands. This is frequently accomplished using additional Fabry-Perot etalons in a series configuration in conjunction with a bandpass filter. This paper discusses a Fabry-Perot interferometer conceptual instrument design to achieve tropospheric and total ozone monitoring capability from a satellite-based nadir-viewing geometry. The design involves a double-etalon fixed-gap series configuration FPI along with an ultra-narrow bandpass filter to achieve single-order operation with an overall spectral resolution of approximately .068 cm(exp -1). The impact of inter-etalon reflections has been reduced to acceptable levels by placement of a slightly attenuating medium in between the etalons. A passive device is selected for low power consumption, and continuous day/night coverage, independent of solar zenith angle, is enabled by observing within the strong 9.6 micron ozone infrared band. The IR-FPI detection will be performed through implementation of the new Circle to Line Interferometer Optical (CLIO) system, developed by researchers at the Space Physics Research Laboratory (SPRL) of the University of Michigan, to accomplish focal plane fringe detection; the CLIO system converts the circular interferometric fringes into a linear pattern which then can be detected by conventional linear array detectors. A multiplex signal advantage is achievable as all necessary frequencies can be measured simultaneously using a multichannel configuration. Through proper selection of channel spectral regions, the FPI optimized for tropospheric O3 measurements can simultaneously observe a stratospheric component and thus the total O3 column abundance.

Larar, Allen M.↗

Image Correlation Pattern Optimization for Micro-Scale In-Situ Strain Measurements

The accuracy and precision of digital image correlation (DIC) is a function of three primary ingredients: image acquisition, image analysis, and the subject of the image. Development of the first two (i.e. image acquisition techniques and image correlation algorithms) has led to widespread use of DIC; however, fewer developments have been focused on the third ingredient. Typically, subjects of DIC images are mechanical specimens with either a natural surface pattern or a pattern applied to the surface. Research in the area of DIC patterns has primarily been aimed at identifying which surface patterns are best suited for DIC, by comparing patterns to each other. Because the easiest and most widespread methods of applying patterns have a high degree of randomness associated with them (e.g., airbrush, spray paint, particle decoration, etc.), less effort has been spent on exact construction of ideal patterns. With the development of patterning techniques such as microstamping and lithography, patterns can be applied to a specimen pixel by pixel from a patterned image. In these cases, especially because the patterns are reused many times, an optimal pattern is sought such that error introduced into DIC from the pattern is minimized. DIC consists of tracking the motion of an array of nodes from a reference image to a deformed image. Every pixel in the images has an associated intensity (grayscale) value, with discretization depending on the bit depth of the image. Because individual pixel matching by intensity value yields a non-unique scale-dependent problem, subsets around each node are used for identification. A correlation criteria is used to find the best match of a particular subset of a reference image within a deformed image. The reader is referred to references for enumerations of typical correlation criteria. As illustrated by Schreier and Sutton and Lu and Cary systematic errors can be introduced by representing the underlying deformation with under-matched shape functions. An important implication, as discussed by Sutton et al., is that in the presence of highly localized deformations (e.g., crack fronts), error can be reduced by minimizing the subset size. In other words, smaller subsets allow the more accurate resolution of localized deformations. Contrarily, the choice of optimal subset size has been widely studied and a general consensus is that larger subsets with more information content are less prone to random error. Thus, an optimal subset size balances the systematic error from under matched deformations with random error from measurement noise. The alternative approach pursued in the current work is to choose a small subset size and optimize the information content within (i.e., optimizing an applied DIC pattern), rather than finding an optimal subset size. In the literature, many pattern quality metrics have been proposed, e.g., sum of square intensity gradient (SSSIG), mean subset fluctuation, gray level co-occurrence, autocorrelation-based metrics, and speckle-based metrics. The majority of these metrics were developed to quantify the quality of common pseudo-random patterns after they have been applied, and were not created with the intent of pattern generation. As such, it is found that none of the metrics examined in this study are fit to be the objective function of a pattern generation optimization. In some cases, such as with speckle-based metrics, application to pixel by pixel patterns is ill-conditioned and requires somewhat arbitrary extensions. In other cases, such as with the SSSIG, it is shown that trivial solutions exist for the optimum of the metric which are ill-suited for DIC (such as a checkerboard pattern). In the current work, a multi-metric optimization method is proposed whereby quality is viewed as a combination of individual quality metrics. Specifically, SSSIG and two auto-correlation metrics are used which have generally competitive objectives. Thus, each metric could be viewed as a constraint imposed upon the others, thereby precluding the achievement of their trivial solutions. In this way, optimization produces a pattern which balances the benefits of multiple quality metrics. The resulting pattern, along with randomly generated patterns, is subjected to numerical deformations and analyzed with DIC software. The optimal pattern is shown to outperform randomly generated patterns.

Bomarito, G. F.↗

SU-E-T-328: Dosimetric Impact of Cobalt-Chrome Stabilization Hardware in Paraspinal Radiation Therapy

Purpose: Due to saturation, high density materials Result in an apparent density of 3.2 g/cm{sup 3} in CT images. The true density of traditional titanium stabilization rods (∼4.4 g/cm{sup 3}) is typically ignored in treatment planning. This may not be acceptable for new cobalt-chrome rods with a density of 8.5 g/cm{sup 3}. This study reports the dosimetric impact of cobalt-chrome rods in paraspinal radiotherapy. Methods: For titanium and cobalt-chrome rods, two planning studies were done for both IMRT and VMAT in Varian Eclipse using AAA. 1) The effect of planning without assigning the true rod density was assessed by comparing plans generated with the apparent density and recalculated with the true density for titanium and cobalt-chrome. 2) To test if TPS can compensate for high density rods during optimization. Furthermore, TPS calculation accuracy was verified using MapCheck for a single 20 x 10 cm{sup 2} field. The MapCheck was incrementally shifted to achieve measurement resolution of 1 mm. Results: PTV coverage was ∼0.3% and ∼4.7% lower in plans that were recalculated with the true rod density of titanium and cobalt-chrome, respectively. PTV coverage can be maintained if the correct density is used in optimization. Measurements showed that TPS overestimated the dose locally by up to 11% for cobalt-chrome rods and up to 4% for titanium rods if the density is incorrect. With density corrected, maximum local differences of 6% and 3% were seen for cobalt-chrome and titanium rods, respectively. At 2 cm beneath a rod, electrons scattered from the side of the rod increased the lateral dose and diminished as depth increases. TPS was not able to account for this effect properly even with the true rod density assigned. Conclusion: Neglecting the true density of cobalt-chrome rods can cause under coverage to the PTV. Assigning the correct density during treatment planning can minimize unexpected decrease in PTV dose.

60 APPLIED LIFE SCIENCES↗

Risk-Averse Control of Fractional Diffusion with Uncertain Exponent

In this paper, we introduce and analyze a new class of optimal control problems constrained by elliptic equations with uncertain fractional exponents. We utilize risk measures to formulate the resulting optimization problem. We develop a functional analytic framework, study the existence of solution and rigorously derive the first-order optimality conditions. Additionally, we employ a sample-based approximation for the uncertain exponent and the finite element method to discretize in space. Further, we prove the rate of convergence for the optimal risk neutral controls when using quadrature approximation for the uncertain exponent and conclude with illustrative examples.

finite element method↗

Information theory optimization of signals from small-angle scattering measurements

Small-angle X-ray scattering (SAXS) of particles in solution informs on the conformational states and assemblies of biological macromolecules (bioSAXS) outside of cryo- and solid-state conditions. In bioSAXS, the SAXS measurement under dilute conditions is resolution limited, and through an inverse Fourier transform, the measured SAXS intensities directly relate to the physical space occupied by the particles via the P (r)-distribution. Yet, this inverse transform of SAXS data has been historically cast as an ill-posed, ill-conditioned problem requiring an indirect approach. Here, we show that through the applications of matrix and information theories, the inverse transform of SAXS intensity data is a well-conditioned problem. The so-called ill-conditioning of the inverse problem is directly related to the Shannon number. By exploiting the oversampling enabled by modern detectors, a direct inverse Fourier transform of the SAXS data is possible, provided the recovered information does not exceed the Shannon number. The Shannon limit corresponds to the maximum number of significant singular values that can be recovered in a SAXS experiment, suggesting this relationship is a fundamental property of band-limited inverse integral transform problems. This correspondence reduces the complexity of the inverse problem to the Shannon limit and maximum dimension. We propose a hybrid scoring function using an information theory framework that assesses both the quality of the model-data fit as well as the quality of the recovered P (r)-distribution. The hybrid score utilizes the Akaike information criteria and Durbin-Watson statistic that considers parameter-model complexity, i.e., degrees of freedom, and the randomness of the model-data residuals. The described tests and findings extend the boundaries for bioSAXS by completing the information theory formalism initiated by Peter B. Moore to enable a quantitative measure of resolution in SAXS, robustly determine maximum dimension, and more precisely define the best parameter model appropriately representing the observed scattering data.

Rambo, Robert P. [Science and Technology Facilitie↗