Search NASA⌕ Search

SEARCH · Search NASA

Results for “Measurement error”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

SU-D-210-07: The Dependence On Acoustic Velocity of Medium On the Needle Template and Electronic Grid Alignment in Ultrasound QA for Prostate Brachytherapy

Purpose: To analyze the impact on acoustic velocity (AV) of two different media (water and milk) using the needle template/electronic grid alignment test. Water, easily available, makes a good material to test the alignment of the template and grid although water’s AV (1498 m/s at 25°C) is significantly different from tissue (1540 m/s). Milk, with an AV much closer (1548 m/s) to prostate tissue, may be a good substitute for water in ultrasound quality assurance testing. Methods: Tests were performed using a Hitachi ultrasound unit with a mechanical arrangement designed to position needles parallel to the transducer. In this work, two materials – distilled water and homogenized whole milk (AVs of 1498 and 1548 m/s at 25°C) were used in a phantom to test ultrasound needle/grid alignment. The images were obtained with both materials and analyzed for their placement accuracy. Results: The needle template/electronic grid alignment tests showed displacement errors between measured and calculated values. The measurements showed displacements of 2.3mm (water) and 0.4mm (milk), and 1.6mm (water) and 0.3mm (milk) at depths of 7cm and 5cm respectively from true needle positions. The calculated results showed a displacement of 2.36 mm (water); 0.435mm (milk), and 1.66mm (water) and 0.31mm (milk) at a depth of 7cm and 5cm respectively. The displacements in the X and Y directions were also calculated. At depths of 7cm and 5cm, the (ΔX,ΔY) displacements in water were (0.829mm, 2.21mm) and (0.273mm, 1.634mm) and for milk were (0.15mm, 0.44mm) and (0.05mm, 0.302mm) respectively. Conclusion: The measured and calculated values were in good agreement for all tests. They show that milk provides superior results when performing needle template and electronic grid alignment tests for ultrasound units used in prostate brachytherapy.

60 APPLIED LIFE SCIENCES↗

An indirect approach to optimize the reaction rates of thermal NO formation for diesel engines

With stringent emission regulations, it has become more important for modern diesel engine manufacturers to accurately predict engine-out nitrogen oxide (NO x ) emissions across a wide range of operating conditions. Thermal NO is the major source of engine-out NO x in modern diesel engines. For thermal NO formation, several earlier studies have recommended the forward and reverse reaction rate coefficients of the rate-limiting reaction (O + N 2 ⇌ NO + N). However, due to deficiencies in sub-models and inadequacies of reduced chemical mechanisms to represent diesel combustion, these recommended values more often than not need to be adjusted in reduced order combustion models to accurately predict engine-out NO x . Hence, in this work a systematic and computationally efficient approach has been proposed to streamline the process of determining the optimum reaction rate coefficients. Here, to develop the optimization approach, four different production diesel engines with different operating conditions in terms of speed, load, and exhaust-gas recirculation have been considered. Numerical simulations have been performed using a detailed zero-dimensional velocity-composition-frequency transported probability density function (0D-VCF-tPDF) model that uses hundreds of notional particles to capture in-cylinder stratification. Four different combinations of hydrocarbon and NO x chemical mechanisms were used to represent chemistry. It was found that for the rate-limiting reaction, the pre-exponent factors (A f1 , A r1 ) and activation energies (E A,f1 , E A,r1 ) of the forward and reverse reaction rates follow a linear band in A f1 - E A,f1 and A r1 - E A,r1 space where predicted engine-out NO x match the measured values closely. By encompassing such bands from different engines and considering constraints on activation energies, a reduced search domain of pre-exponent factors and activation energies was constructed that is expected to be applicable to any diesel engine. Eventually, computationally efficient three-line and one-line search approaches were proposed to determine the optimum values of the pre-exponent factors and activation energies that led to a minimum error between measured and predicted engine-out NO x . Finally, these three-line and one-line NO x optimization approaches were applied to a fifth production diesel engine for which the 0D-VCF-tPDF model showed a very good predictive performance in terms of predicting peak pressure, 50% burn rate, and engine-out NO x when compared to measured and 3D-CFD values.

33 ADVANCED PROPULSION SYSTEMS↗

The Mass–Concentration Relation and the Stellar-to-halo Mass Ratio in the CFHT Stripe 82 Survey

We present a new measurement of the mass–concentration relation and the stellar-to-halo mass ratio over the halo-mass range 5 × 10{sup 12} to 2 × 10{sup 14} M {sub ⊙}. To achieve this, we use weak lensing measurements from the Canada–France–Hawaii Telescope Stripe 82 Survey (CS82), combined with the central galaxies from the redMaPPer cluster catalog and the LOWZ/CMASS galaxy sample of the Sloan Digital Sky Survey-III Baryon Oscillation Spectroscopic Survey Tenth Data Release. The stacked lensing signals around these samples are modeled as a sum of contributions from the central galaxy, its dark matter halo, and the neighboring halos, as well as a term for possible centering errors. We measure the mass–concentration relation: c{sub 200c}(M)=A(((M{sub 200c})/(M{sub 0}))){sup B} with A = 5.24 ± 1.24, B = −0.13 ± 0.10 for 0.2 < z < 0.4, and A = 6.61 ± 0.75, B = −0.15 ± 0.05 for 0.4 < z < 0.6. These amplitudes and slopes are completely consistent with predictions from recent simulations. We also measure the stellar-to-halo mass ratio for our samples, and find results consistent with previous measurements from lensing and other techniques.

79 ASTRONOMY AND ASTROPHYSICS↗

Error-correcting Bacon-Shor code with continuous measurement of noncommuting operators

We analyze the continuous operation of the nine-qubit error correcting Bacon-Shor code with all noncommuting gauge operators measured at the same time. The error syndromes are continuously monitored using cross-correlations of sets of three measurement signals. We calculate the logical error rates due to $X$, $Y$ and $Z$ errors in the physical qubits and compare the continuous implementation with the discrete operation of the code. We find that both modes of operation exhibit similar performances when the measurement strength from continuous measurements is sufficiently strong. Here, we also estimate the value of the crossover error rate of the physical qubits, below which continuous error correction gives smaller logical error rates. Continuous operation has the advantage of passive monitoring of errors and avoids the need for additional circuits involving ancilla qubits.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Functional representation of tissue phantom ratios for photon fields

Purpose: The tissue phantom ratio (TPR) is a common dosimetric quantity used in photon dose calculations. For small photon fields with side lengths less than 4 cm, TPR data hardly exist in literature. In this work, a self-contained functional representation of TPR is proposed, valid for the whole range of clinically relevant depth and field sizes. This is especially useful for small fields shaped by multileaf collimators. Methods: TPRs were measured for quadratic fields with side lengths between 0.4 and 18 cm. The measured data were fitted to a physically meaningful function taking electron buildup, buildup of scattered photons, beam attenuation, and beam hardening into account. The achievable accuracy was tested against measurement and data from the literature. Results: A set of parameters for the proposed function was derived for 6 and 10 MV beams. The comparison of the calculated and the measured data generally yielded a difference of less than 1%. For field sizes below 2 cm, a systematic discrepancy between the author's data and those from Cheng et al. [Med. Phys 34, 3149-3157 (2007)] was found. Conclusions: With the proposed model, TPRs can be calculated for the full range of field sizes and depths required by treatment planning system algorithms and monitor unit check programs with very high accuracy. The method is also useful in detecting and reducing errors in measurement.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Measurements of the electron density and degree of plasma ionization in a plasma target based on a linear electric discharge in hydrogen

Laser interferometry methods were used to measure the density of free electrons and degree of plasma ionization in a hydrogen target intended for experiments on determining energy losses of heavy ion beams in an ionized matter. It is shown that the linear electron density can be varied in the range from 3.3 Multiplication-Sign 10{sup 17} to 1.3 Multiplication-Sign 10{sup 18} cm{sup -2} by varying the initial plasma parameters (the hydrogen pressure in the target and the discharge current). The error in measuring the linear electron density in the entire range of the varied plasma parameters was less than 1%. The maximum degree of plasma ionization achieved at the initial gas pressure of 1 mbar was 0.62 {+-} 0.05.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

SU-E-J-177: A Computational Approach for Determination of Anisotropic PTV Margins Based On Statistical Shape Analysis for Prostate Cancer Radiotherapy

Purpose: Our aim of this study was to propose a computational approach for determination of anisotropic planning target volume (PTV) margins based on statistical shape analysis with taking into account time variations of clinical target volume (CTV) shapes for the prostate cancer radiation treatment planning (RTP). Methods: Systematic and random setup errors were measured using orthogonal projection and cone beam computed tomography (CBCT) images for data of 20 patients, who underwent the intensity modulated radiation therapy for prostate cancer. The low-risk, intermediate-risk, and high-risk CTVs were defined as only a prostate, a prostate plus proximal 1-cm seminal vesicles, and a prostate plus proximal 2-cm seminal vesicles, respectively. All CTV regions were registered with a reference CTV region with a median volume to remove the effect of the setup errors, and converted to a point distribution models. The systematic and random errors for translations of CTV regions were automatically evaluated by analyzing the movements of centroids of CTV regions. The random and systematic errors for shape variations of CTV regions were obtained from covariance matrices based on point distributions for the CTV contours on CBCT images of 72 fractions of 10 patients. Anisotropic PTV margins for 6 directions (right, left, anterior, posterior, superior and inferior) were derived by using Yoda’s PTV margin model. Results: PTV margins with and without shape variations were 5.75 to 8.03 mm and 5.23 to 7.67 mm for low-risk group, 5.87 to 8.33 mm and 5.23 to 7.67 mm for intermediate-risk group, and 5.88 to 8.25 mm and 5.29 to 7.82 mm for highrisk group, respectively. Conclusion: The proposed computational approach could be feasible for determination of the anisotropic PTV margins with taking into account CTV shape variations for the RTP.

60 APPLIED LIFE SCIENCES↗

Evidence for B - → τ - ν ¯ τ with a Hadronic Tagging Method Using the Full Data Sample of Belle

In this work, we measure the branching fraction of B - → τ - ν ¯ τ using the full Υ ( 4 S ) data sample containing 772 × 10 6 B B ¯ pairs collected with the Belle detector at the KEKB asymmetric-energy e + e - collider. Events with B B ¯ pairs are tagged by reconstructing one of the B mesons decaying into hadronic final states, and B - → τ - ν ¯ τ candidates are detected in the recoil. We discover evidence for B - → τ - ν ¯ τ with a significance of 3.0 standard deviations including systematic errors and measure a branching fraction B ( B - → τ - ν ¯ τ ) = [ 0.72 - 0.25 + 0.27 ( stat ) ± 0.11 ( syst ) ] × 10 - 4 .

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

EXPERIMENTAL DETERMINATION OF THE RATE CONSTANT FOR THE ASSOCIATIVE DETACHMENT REACTION H{sup -} + H -> H{sub 2} + e {sup -} AT 300 K

We have determined the rate constant for the associative detachment reaction of hydride ions with hydrogen atoms (H{sup -} + H -> H{sub 2} + e {sup -}) at 300 K to be 2.0 (+-0.6) x 10{sup -9} cm{sup 3} s{sup -1}, where the error bars represent the total absolute error and include 1sigma of the measured values; the error analysis is described in the Appendix. Experiments were carried out in a flowing afterglow instrument using the well-characterized reactions of Cl{sup -} + H and OH{sup -} + H to calibrate the concentration of hydrogen atoms. Our measurement represents a significant improvement over previous determinations and will reduce uncertainties in cosmological models that rely on this reaction rate constant.

79 ASTRONOMY AND ASTROPHYSICS↗

Individual Load Model Parameter Estimation in Distribution Systems Using Load Switching Events

There currently exists a mature literature on modeling the aggregate load of a distribution feeder by making use of measurements at its feeder-head at substation. The primary application of such feeder-aggregated load models is in sub-transmission or transmission system analysis. However, there is a growing need in practice also to model each individual load across the feeder. If available, such individual load models have applications in power distribution system analysis, e.g., to better integrate distributed energy resources or to improve power quality and reliability. Motivated by this observation, in this paper, we propose a new method for individual load modeling in power distribution systems. It works by using the measurements only at the feeder-head. It takes an innovative approach to analyzing the load switching events across the distribution feeder itself, instead of or in addition to relying on upstream voltage events that are commonly used in feeder-aggregated load modeling. By tracking the downstream load switching events, the proposed method can make a robust estimation of the ZIP load model parameters for all individual loads. The proposed method is examined on small illustrative test-feeders as well as the IEEE 33-bus test system under various operating scenarios. The adverse impact of errors in measurements and system parameters are also investigated on the performance of the developed load modeling method.

24 POWER TRANSMISSION AND DISTRIBUTION↗

How to avoid multiple scattering in strongly scattering SANS and USANS samples

Small Angle Neutron Scattering (SANS) and Ultra Small Angle Neutron Scattering (USANS) are the only available experimental techniques to provide seamless non-destructive measurements of the geometry of the accessible and inaccessible pore structure of rocks from sub-nanopore size to the scale of macropores. They have therefore become the measurement of choice for tight reservoir rocks such as organic rich shales. A simplifying assumption in the analysis is, however, that during the path of neutrons through the sample each neutron is only scattered once. Shales are samples with a high scattering power and Multiple Scattering (MS) may occur which requires special modelling for deconvolution of the results. The approach to avoid MS is to simply reduce the sample thickness to <0.15–0.5 mm. Here, in this work, we present a systematic method on wavelength selection and preparation of samples to optimise extraction of microstructural data and minimise parasitic errors. Experimentally measured SAS transmission (TSAS) values are used as a practical criterion for estimation of the extent of MS. Generous beamtime allocations allowed robust testing revealing that sample thicknesses can be twice as thick as predicted using the standard protocol. Analysing thicker samples is particularly beneficial for statistically relevant characterisation of heterogeneous samples making the new protocol the method of choice for such samples.

(U)SANS↗

MEASUREMENT OF COSMIC MICROWAVE BACKGROUND POLARIZATION POWER SPECTRA FROM TWO YEARS OF BICEP DATA

Background Imaging of Cosmic Extragalactic Polarization (BICEP) is a bolometric polarimeter designed to measure the inflationary B-mode polarization of the cosmic microwave background (CMB) at degree angular scales. During three seasons of observing at the South Pole (2006 through 2008), BICEP mapped {approx}2% of the sky chosen to be uniquely clean of polarized foreground emission. Here, we present initial results derived from a subset of the data acquired during the first two years. We present maps of temperature, Stokes Q and U, E and B modes, and associated angular power spectra. We demonstrate that the polarization data are self-consistent by performing a series of jackknife tests. We study potential systematic errors in detail and show that they are sub-dominant to the statistical errors. We measure the E-mode angular power spectrum with high precision at 21 <= l <= 335, detecting for the first time the peak expected at l {approx} 140. The measured E-mode spectrum is consistent with expectations from a LAMBDACDM model, and the B-mode spectrum is consistent with zero. The tensor-to-scalar ratio derived from the B-mode spectrum is r = 0.02{sup +0.31}{sub -0.26}, or r < 0.72 at 95% confidence, the first meaningful constraint on the inflationary gravitational wave background to come directly from CMB B-mode polarization.

79 ASTRONOMY AND ASTROPHYSICS↗

Stochastic Error Cancellation in Analog Quantum Simulation

Analog quantum simulation is a promising path towards solving classically intractable problems in many-body physics on near-term quantum devices. However, the presence of noise limits the size of the system and the length of time that can be simulated. In our work, we consider an error model in which the actual Hamiltonian of the simulator differs from the target Hamiltonian we want to simulate by small local perturbations, which are assumed to be random and unbiased. We analyze the error accumulated in observables in this setting and show that, due to stochastic error cancellation, with high probability the error scales as the square root of the number of qubits instead of linearly. We explore the concentration phenomenon of this error as well as its implications for local observables in the thermodynamic limit. Moreover, we show that stochastic error cancellation also manifests in the fidelity between the target state at the end of time-evolution and the actual state we obtain in the presence of noise. This indicates that, to reach a certain fidelity, more noise can be tolerated than implied by the worst-case bound if the noise comes from many statistically independent sources.

Analog quantum simulation↗

Predetermining acceptable noise limits in EXAFS spectra in the limit of stochastic noise

EXAFS measurements are used to probe a variety of experimental systems, but excel at elucidating local structure in samples which have slight disorder or no long-range crystalline order. Of special interest to the authors is the use of EXAFS in understanding the molecular-level binding structure and characteristics of actinides on the surface of environmental minerals and model mineral analogs. In environmental systems the element of interest can be on the order of 10-7% by weight of the total sample. Obviously such samples would be impossible to measure using EXAFS techniques. It is therefore essential to increase the concentration of the element of interest while still preserving a sample's ability to represent environmental conditions. Under such low concentration limits it is expected that the collected data is countrate, or stochastically limited. This condition occurs as we approach the signal-to-noise (S/N) limit of the technique where the random noise of the measurement process dominates over possible systematic errors. When stochastic error is expected to dominate systematic error, it is possible to predict, with the use of simulations, the ability of model fits to tolerate a certain level of stochastic noise. Elsewhere in these proceedings, we discuss how to tell when systematic errors dominate in measured EXAFS spectrum. Here, we outline a technique for determining the number of EXAFS scans necessary to test the relevance of a given structural model. Appropriate stochastic noise levels are determined for each point in r-space by collecting data on a real system. These noise levels are then applied to EXAFS simulations using a test model. In this way, all significant systematic error sources are eliminated in the simulated data. The structural model is then fit to the simulated data, decreasing the noise and increasing the k-range of the fit until the veracity of the model passes an F-test. This paper outlines a method of testing model systems in EXAFS fitting before measurements are conducted to determine the quality of measured data required for fitting of a particular model system with statistical confidence. It is important to reiterate that the calculated {alpha}surface in figure 1 is only applicable to the particular model presented in this paper. Furthermore, this procedure only takes into account stochastic noise; consequentially any confidence levels calculated should be viewed as upper limits to the confidence levels in systems which also contain a significant amount of systematic noise.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Combined high-pressure neutron and X-ray diffraction study of H-D substitution effects on brucite

The high-pressure behavior of the mineral brucite, Mg(OH)2, is of great geochemical and geophysical interest, because brucite-type minerals serve as a simple analog for more complex, hydrogen-bearing oxide and silicate minerals in the deep-earth. A combined neutron and synchrotron x-ray powder diffraction study of hydrogenated and deuterated brucite was conducted at ambient temperature and at pressures to 9 and 20 GPa, using a Paris-Edinburgh (neutron diffraction) and a diamond anvil cell (synchrotron x-ray radiation), respectively. The two materials were synthesized by the same method and companion diffraction measurements of the two materials were conducted under the same conditions. Our experimental results show that the lattice-parameters of the a axis, parallel to the sheets of Mg-O octahedra, decrease only slightly with pressure with no effect of H-D substitution. However, the c axis of Mg (OD)2 is shorter and may exhibit greater compressibility with pressure than that of Mg (OH)2. Consequently, the unit-cell volume of deuterated brucite is slightly, but systematically smaller than that of hydrogenated brucite. Fitting to a third-order Birch-Murnaghan equation shows that values of the bulk modulus for hydrogenated and deuterated brucite are indistinguishable from each other within the experimental errors. The measured effect of H-D substitution on the unit-cell volume demonstrates that brucite (and other hydrous minerals) preferentially incorporate deuterium over hydrogen under pressure, suggesting that the distribution of hydrogen isotopes in deep-earth conditions may differ significantly from that in near-surface environments.

Brucite↗

A three dimensional probe positioner

In order to sort out the physics that is important in many plasma experiments, data in three dimensions (3D) are becoming necessary. Access to the usual cylindrical vacuum vessel is typically restricted to radially or axially insertable probes that can pivot. The space that can be explored usually has significant restrictions either because probe travel must be along a travel path, or a 'wobbly' probe positioner requires one to map between a moveable coordinate system and a preferred laboratory coordinate system. This could for example introduce errors in measurements of vector quantities such as magnetic field or flow. We describe the design and implementation of a 3D probe positioner that slides in two dimensions on a double O-ring seal and radially inserts along the third dimension. The net result is that a 3D space can be explored in a laboratory Cartesian reference frame.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Combined high-pressure neutron and X-ray diffraction study of H-D substitution effects on brucite

The high-pressure behavior of the mineral brucite, Mg(OH){sub 2}, is of great geochemical and geophysical interest, because brucite-type minerals serve as a simple analog for more complex, hydrogen-bearing oxide and silicate minerals in the deep-earth. A combined neutron and synchrotron x-ray powder diffraction study of hydrogenated and deuterated brucite was conducted at ambient temperature and at pressures to 9 and 20 GPa, using a Paris-Edinburgh (neutron diffraction) and a diamond anvil cell (synchrotron x-ray radiation), respectively. The two materials were synthesized by the same method and companion diffraction measurements of the two materials were conducted under the same conditions. Our experimental results show that the lattice-parameters of the a axis, parallel to the sheets of Mg-O octahedra, decrease only slightly with pressure with no effect of H-D substitution. However, the c axis of Mg (OD){sub 2} is shorter and may exhibit greater compressibility with pressure than that of Mg (OH){sub 2}. Consequently, the unit-cell volume of deuterated brucite is slightly, but systematically smaller than that of hydrogenated brucite. Fitting to a third-order Birch-Murnaghan equation shows that values of the bulk modulus for hydrogenated and deuterated brucite are indistinguishable from each other within the experimental errors. The measured effect of H-D substitution on the unit-cell volume demonstrates that brucite (and other hydrous minerals) preferentially incorporate deuterium over hydrogen under pressure, suggesting that the distribution of hydrogen isotopes in deep-earth conditions may differ significantly from that in near-surface environments.

36 MATERIALS SCIENCE↗

Planck 2013 results. XVI. Cosmological parameters

This paper presents the first cosmological results based on Planck measurements of the cosmic microwave background (CMB) temperature and lensing-potential power spectra. We find that the Planck spectra at high multipoles (&ell; ≳ 40) are extremely well described by the standard spatially-flat six-parameter ΛCDM cosmology with a power-law spectrum of adiabatic scalar perturbations. Within the context of this cosmology, the Planck data determine the cosmological parameters to high precision: the angular size of the sound horizon at recombination, the physical densities of baryons and cold dark matter, and the scalar spectral index are estimated to be θ &lowast; = (1.04147 ± 0.00062) × 10 -2 , Ω b h 2 = 0.02205 ± 0.00028, Ω c h 2 = 0.1199 ± 0.0027, and n s = 0.9603 ± 0.0073, respectively (note that in this abstract we quote 68% errors on measured parameters and 95% upper limits on other parameters). For this cosmology, we find a low value of the Hubble constant, H 0 = (67.3 ± 1.2) km s -1 Mpc -1 , and a high value of the matter density parameter, Ω m = 0.315 ± 0.017. These values are in tension with recent direct measurements of H 0 and the magnitude-redshift relation for Type Ia supernovae, but are in excellent agreement with geometrical constraints from baryon acoustic oscillation (BAO) surveys. Including curvature, we find that the Universe is consistent with spatial flatness to percent level precision using Planck CMB data alone. We use high-resolution CMB data together with Planck to provide greater control on extragalactic foreground components in an investigation of extensions to the six-parameter ΛCDM model. We present selected results from a large grid of cosmological models, using a range of additional astrophysical data sets in addition to Planck and high-resolution CMB data. None of these models are favoured over the standard six-parameter ΛCDM cosmology. The deviation of the scalar spectral index from unity is insensitive to the addition of tensor modes and to changes in the matter content of the Universe. We find an upper limit of r 0.002 < 0.11 on the tensor-to-scalar ratio. There is no evidence for additional neutrino-like relativistic particles beyond the three families of neutrinos in the standard model. Using BAO and CMB data, we find N eff = 3.30 ± 0.27 for the effective number of relativistic degrees of freedom, and an upper limit of 0.23 eV for the sum of neutrino masses. Our results are in excellent agreement with big bang nucleosynthesis and the standard value of N eff = 3.046. We find no evidence for dynamical dark energy; using BAO and CMB data, the dark energy equation of state parameter is constrained to be w = -1.13 -0.10 +0.13 . We also use the Planck data to set limits on a possible variation of the fine-structure constant, dark matter annihilation and primordial magnetic fields. Despite the success of the six-parameter ΛCDM model in describing the Planck data at high multipoles, we note that this cosmology does not provide a good fit to the temperature power spectrum at low multipoles. The unusual shape of the spectrum in the multipole range 20 ≲ &ell; ≲ 40 was seen previously in the WMAP data and is a real feature of the primordial CMB anisotropies. The poor fit to the spectrum at low multipoles is not of decisive significance, but is an "anomaly" in an otherwise self-consistent analysis of the Planck temperature data.

79 ASTRONOMY AND ASTROPHYSICS↗