Search NASA⌕ Search

SEARCH · Search NASA

Results for “Microfluidic”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Active mixing of complex fluids at the microscale

Mixing of complex fluids at low Reynolds number is fundamental for a broad range of applications, including materials assembly, microfluidics, and biomedical devices. Of these materials, yield stress fluids (and gels) pose the most significant challenges, especially when they must be mixed in low volumes over short timescales. New scaling relationships between mixer dimensions and operating conditions are derived and experimentally verified to create a framework for designing active microfluidic mixers that can efficiently homogenize a wide range of complex fluids. As a result, active mixing printheads are then designed and implemented for multimaterial 3D printing of viscoelastic inks with programmable control of local composition.

36 MATERIALS SCIENCE↗

The liquid state of FG-nucleoporins mimics permeability barrier properties of nuclear pore complexes

Nuclear pore complexes (NPCs) regulate all cargo traffic across the nuclear envelope. The transport conduit of NPCs is highly enriched in disordered phenylalanine/glycine-rich nucleoporins (FG-Nups), which form a permeability barrier of still elusive and highly debated molecular structure. Here we present a microfluidic device that triggered liquid-to-liquid phase separation of FG-Nups, which yielded droplets that showed typical properties of a liquid state. On the microfluidic chip, droplets were perfused with different transport-competent or -incompetent cargo complexes, and then the permeability barrier properties of the droplets were optically interrogated. We show that the liquid state mimics permeability barrier properties of the physiological nuclear transport pathway in intact NPCs in cells: that is, inert cargoes ranging from small proteins to large capsids were excluded from liquid FG-Nup droplets, but functional import complexes underwent facilitated import into droplets. Collectively, these data provide an experimental model of how NPCs can facilitate fast passage of cargoes across an order of magnitude in cargo size.

59 BASIC BIOLOGICAL SCIENCES↗

Liquid Crystal Optofluidics

By employing anisotropic fluids and namely liquid crystals, fluid flow becomes an additional degree of freedom in designing optofluidic devices. In this paper, we demonstrate optofluidic liquid crystal devices based on the direct flow of nematic liquid crystals in microfluidic channels. Contrary to previous reports, in the present embodiment we employ the effective phase delay acquired by light travelling through flowing liquid crystal, without analysing the polarisation state of the transmitted light. With this method, we demonstrate the variation in the diffraction pattern of an array of microfluidic channels acting as a grating. We also discuss our recent activities in integrating mechanical oscillators for on-chip peristaltic pumping.

crystals↗

Hybrid opto-electric techniques for molecular diagnostics

Hybrid optoelectric techniques reflect a new paradigm in microfluidics. In essence, these are microfluidic techniques that employ a synergistic combination of optical and electrical forces to enable noninvasive manipulation of fluids and/or particle-type entities at the micro/nano-scale [1]. Synergy between optical and electrical forces bestows these techniques with several unique features that are promising to bring new opportunities in molecular diagnostics. Within the scope of molecular diagnostics, several aspects of optoelectric techniques promise to play a relevant role. These include, but are not limited to, sample preparation, sorting, purification, amplification and detection.

99 GENERAL AND MISCELLANEOUS↗

Unravel lipid accumulation mechanism in oleaginous yeast through single cell systems biology study

Searching for alternative and clean energy is one of the most important tasks today. Our research aimed at finding the best living condition for certain types of oleaginous yeasts for efficient lipid production. We found that R. glutinis yeast cells has great variability in lipid production among cells while Y. lipolytica cells has similar oil production ability. We found some individual cells shows much higher level of oil production. In order to further study these cases, we employed a label-free chemical sensitive microscopy method call stimulated Raman scattering (SRS). With SRS, we could measure the lipid content in each cell. We combined SRS microscopy with microfluidic device so that we can isolate cells with high fat content. We also developed SRS imaging technique that has higher imaging speed, which is highly desirable for high throughput cell screening and sorting. Since these cells has similar genome, it must be the transcriptome caused their difference in oil production. We developed a single cell transcriptome sequencing method to study which genes are responsible for elevated oil production. These methods that are developed for this project can easily be applied for many other areas of research. For example, the single transcriptome can be used to study the transcriptomes of other cell types. The high-speed SRS microscopy techniques can be used to speed up chemical imaging for lablefree histology or imaging distribution of chemicals in tissues of live mice or in humans. The developed microfluidic platform can be used to sort other type of cells, e.g., white blood cells for diagnosis of cancer or other blood diseases.

09 BIOMASS FUELS↗

Mesoscale fractal whey protein particles derived from microscale linear-shaped protein assemblies (Part 1): Manufacturing method and particle characteristics

Whey protein isolates (WPI) are widely used in processed foods for their versatile functional properties. Modifying the structural properties of proteins by assembling them into mesoscale or microscale particles may improve their functionality and broaden their applications. This study aims to manufacture and characterize mesoscale whey protein particles (WPP) derived from WPI. Two types of WPP, WPP1 (0.05 mL/min) and WPP2 (0.25 mL/min), were prepared through a multistep approach involving liquid antisolvent (LAS) precipitation, heat treatment, and microfluidization. Liquid antisolvent precipitation was performed by injecting a 20% (wt/vol) WPI dispersion (pH 7) into an ethanol-glycerol mixture (75:25, vol/vol) under laminar flow, followed by heat treatment at 80°C for 20 min as a particle hardening step. This process produced stable fiber- and ribbon-shaped whey protein assemblies (WPA), which served as precursors to WPP. Subsequent microfluidization (150 MPa, 6 passages) reduced the size of WPA, yielding mesoscale WPP with irregular morphologies and a more uniform size distribution, as revealed by microscopy and dynamic light scattering. ζ-Potential and fluorescence labeling indicated higher surface charge and surface hydrophobicity of WPP compared with untreated WPI. The WPP showed internal mass fractal and surface fractal structures at larger length scales, analyzed using small-angle X-ray scattering. Fourier transform infrared spectroscopy demonstrated an increased fraction of intermolecular β-sheets in WPP, suggesting that hydrogen bonding contributed to their formation. Gel electrophoresis confirmed that disulfide bonds served as the primary cross-links stabilizing the WPP structure. Furthermore, turbidity measurements showed that WPP exhibited superior colloidal phase stability compared with untreated WPI and maintained high colloidal stability under both acidic and neutral pH conditions.

Antisolvent precipitation↗

Analysis of Factors Limiting Bacterial Growth in PDMS Mother Machine Devices

The microfluidic mother machine platform has attracted much interest for its potential in studies of bacterial physiology, cellular organization, and cell mechanics. Despite numerous experiments and development of dedicated analysis software, differences in bacterial growth and morphology in narrow mother machine channels compared to typical liquid media conditions have not been systematically characterized. Here we determine changes in E. coli growth rates and cell dimensions in different sized dead-end microfluidic channels using high resolution optical microscopy. We find that E. coli adapt to the confined channel environment by becoming narrower and longer compared to the same strain grown in liquid culture. Cell dimensions decrease as the channel length increases and width decreases. These changes are accompanied by increases in doubling times in agreement with the universal growth law. In channels 100 μm and longer, cell doublings can completely stop as a result of frictional forces that oppose cell elongation. Before complete cessation of elongation, mechanical stresses lead to substantial deformation of cells and changes in their morphology. Lastly, our work shows that mechanical forces rather than nutrient limitation are the main growth limiting factor for bacterial growth in long and narrow channels.

59 BASIC BIOLOGICAL SCIENCES↗

ON-DEMAND SERIAL DILUTION USING QUANTIZED NANO/PICOLITER-SCALE DROPLETS

This paper describes a fully automated droplet-based microfluidic device for on-demand serial dilution that is capable of achieving a dilution ratio of >6000 (concentration ranges from 1 mM to 160nM) over 35 nanoliter-scale droplets. This serial diluter can be applied to high throughput and label-free kinetic assays by integrating with our previously developed on-demand droplet-based microfluidic with mass spectrometry detection.

Droplet microfluidics, Serial dilution, Concentrat↗

Fluidic Processing of High-Performance ZIF-8 Membranes on Polymeric Hollow Fibers: Mechanistic Insights and Microstructure Control

Recently, a methodology for fabricating polycrystalline metal-organic framework (MOF) membranes has been introduced – referred to as interfacial microfluidic membrane processing – which allows parallelizable fabrication of MOF membranes inside polymeric hollow fibers of microscopic diameter. Such hollow fiber membranes, when bundled together into modules, are an attractive way to scale molecular sieving membranes. The understanding and engineering of fluidic processing techniques for MOF membrane fabrication are in their infancy. Here in this work, a detailed mechanistic understanding of MOF (ZIF-8) membrane growth under microfluidic conditions in polyamide-imide hollow fibers is reported, without any intermediate steps (such as seeding or surface modification) or post-synthesis treatments. A key finding is that interfacial membrane formation in the hollow fiber occurs via an initial formation of two distinct layers and the subsequent rearrangement into a single layer. This understanding is used to show how nonisothermal processing allows fabrication of thinner (5 μm) ZIF-8 films for higher throughput, and furthermore how engineering the polymeric hollow fiber support microstructure allows control of defects in the ZIF-8 membranes. Finally, the performance of these engineered ZIF-8 membranes is then characterized, which have H 2 /C 3 H 8 and C 3 H 6 /C 3 H 8 mixture separation factors as high as 2018 and 65, respectively, and C 3 H 6 permeances as high as 66 GPU.

36 MATERIALS SCIENCE↗

Extreme Two‐Phase Cooling from Laser‐Etched Diamond and Conformal, Template‐Fabricated Microporous Copper

Abstract This paper reports the first integration of laser‐etched polycrystalline diamond microchannels with template‐fabricated microporous copper for extreme convective boiling in a composite heat sink for power electronics and energy conversion. Diamond offers the highest thermal conductivity near room temperature, and enables aggressive heat spreading along triangular channel walls with 1:1 aspect ratio. Conformally coated porous copper with thickness 25 µm and 5 µm pore size optimizes fluid and heat transport for convective boiling within the diamond channels. Data reported here include 1280 W cm −2 of heat removal from 0.7 cm 2 surface area with temperature rise beyond fluid saturation less than 21 K, corresponding to 6.3 × 10 5 W m −2 K −1 . This heat sink has the potential to dissipate much larger localized heat loads with small temperature nonuniformity (5 kW cm −2 over 200 µm × 200 µm with <3 K temperature difference). A microfluidic manifold assures uniform distribution of liquid over the heat sink surface with negligible pumping power requirements (e.g., <1.4 × 10 −4 of the thermal power dissipated). This breakthrough integration of functional materials and the resulting experimental data set a very high bar for microfluidic heat removal.

Palko, James W.↗

An All Hydrophilic Fluid Diode for Unidirectional Flow in Porous Systems

Abstract A fluid diode that allows fluid flow in one direction but blocks fluid flow in the opposite direction has wide applications including oil recovery, drug delivery, and lab‐on‐a‐chip microfluidics. Many studies are conducted to facilitate directional liquid motion on the solid surface or across thin porous layers. However, the self‐driven one‐way flow inside porous systems still remains a significant challenge. Here, a novel all‐hydrophilic fluid diode (AHFD) made of porous materials with asymmetric pores is reported, which allows capillary flow in a chosen direction. The direction‐dependent flow process and the breakthrough pressure are experimentally and theoretically examined. The proposed AHFD can have many potential applications such as functional protective clothing, microfluidic valve, and oil–water separator, and the idea can be extended to develop other all lyophilic fluid diodes such as oleophilic diode.

Shou, Dahua↗

Functional nanostructured plasmonic materials.

Plasmonic crystals fabricated with precisely controlled arrays of subwavelength metal nanostructures provide a promising platform for sensing and imaging of surface binding events with micrometer spatial resolution over large areas. Soft nanoimprint lithography provides a robust, cost-effective method for producing highly uniform plasmonic crystals of this type with predictable optical properties. The tunable multimode plasmonic resonances of these crystals and their ability for integration into lab-on-a-chip microfluidic systems can both be harnessed to achieve exceptionally high analytical sensitivities down to submonolayer levels using even a common optical microscope, circumventing numerous technical limitations of more conventional surface plasmon resonance techniques. In this article, we highlight some recent advances in this field with an emphasis on the fabrication and characterization of these integrated devices and their demonstrated applications.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Microfabricated systems and assays for studying the cytoskeletal organization, micromechanics, and motility patterns of cancerous cells

Cell motions are driven by coordinated actions of the intracellular cytoskeleton – actin, microtubules (MTs) and substrate/focal adhesions (FAs). This coordination is altered in metastatic cancer cells resulting in deregulated and increased cellular motility. Microfabrication tools, including photolithography, micromolding, microcontact printing, wet stamping and microfluidic devices have emerged as a powerful set of experimental tools with which to probe and define the differences in cytoskeleton organization/dynamics and cell motility patterns in non-metastatic and metastatic cancer cells. In this paper, we discuss four categories of microfabricated systems: (i) micropatterned substrates for studying of cell motility sub-processes (for example, MT targeting of FAs or cell polarization); (ii) systems for studying cell mechanical properties, (iii) systems for probing overall cell motility patterns within challenging geometric confines relevant to metastasis (for example, linear and ratchet geometries), and (iv) microfluidic devices that incorporate co-cultures of multiple cell types and chemical gradients to mimic in vivo intravasation/extravasation steps of metastasis. Finally, together, these systems allow for creating controlled microenvironments that not only mimic complex soft tissues, but are also compatible with live cell high-resolution imaging and quantitative analysis of single cell behavior.

59 BASIC BIOLOGICAL SCIENCES↗

Dilution-Free Analysis from Picoliter Droplets by Nano-Electrospray Ionization Mass Spectrometry

The expanding role of microfluidics for chemical and biochemical analysis is due to factors including the favorable scaling of separation performance with reduced channel dimensions,[1] flexibility afforded by computer-aided device design, and the ability to integrate multiple sample handling and analysis steps into a single platform.[2] Such devices enable smaller liquid volumes and sample sizes to be handled than can be achieved on the benchtop, where sub-microliter volumes are difficult to work with and where sample losses to the surfaces of multiple reaction vessels become prohibitive. A particularly attractive microfluidic platform for sample-limited analyses employs aqueous droplets or plugs encapsulated by an immiscible oil.[3,4] Each droplet serves as a discrete compartment or reaction chamber enabling, e.g., high throughput screening[5,6] and kinetic studies[7-9] of femto- to nanoliter samples, as well as the encapsulation[10-12] and lysis[10] of individual cells with limited dilution of the cellular contents

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

ToF-SIMS characterization of glyoxal surface oxidation products by hydrogen peroxide: A comparison between dry and liquid samples

As one of the simplest volatile organic compounds (VOCs), glyoxal and its oxidation products were considered to be important precursors to aqueous secondary organic aerosol (aqSOA) formation. Herein, we analyzed products from glyoxal oxidation by hydrogen peroxide in dry and liquid samples using time-of-flight secondary ion mass spectrometry (ToF-SIMS). ToF-SIMS spectra and spectral principal component analysis (PCA) were used to investigate surface oxidation products. Dry samples were prepared on clean silicon wafers. Liquid samples consisting of glyoxal and hydrogen peroxide (H2O2) were introduced to a vacuum compatible microfluidic reactor prior to UV illumination or dark aging followed by in situ liquid SIMS analysis. A number of reaction products were observed in both dry and liquid samples; different oligomers and carboxylic acids could be formed depending on reaction conditions. In addition, hydrolyzed products were observed in the liquid samples, but not in the dry samples. Although dry samples reveal some products of the aqueous process, they are not fully representative as results from those of the aqueous samples. Our findings suggest that the ability to characterize the liquid surface reaction products provides more realistic information of the reaction products associated with aqSOA formation in the atmosphere. Meanwhile, the high mass resolution spectra from the dry sample SIMS measurement are helpful to identify oxidation products in the liquid samples.

, Aqueous Secondary Organic Aerosol, Sample Prepar↗

In situ liquid SIMS analysis of uranium oxide

Trace analysis of nuclear materials in solid particles collected in the environment or particles in liquid slurry generated in nuclear material manufacturing processes can pinpoint elemental, organic, and isotopic signatures of nuclear fuel cycle activities and processes. Such information can support nuclear safeguards programs by increasing our ability to detect undeclared nuclear materials, routine activities for safeguarding at declared facilities, and illicit activities. However, trace radioactive material analysis in liquids and slurries is challenging using bulk approaches. For example, one drawback of sensitive analysis such as inductively coupled plasma mass spectrometry (ICP-MS) is that sample is consumed or destroyed as a result of the technical approach. We developed a vacuum compatible microfluidic interface to enable surface analysis of liquids and liquid-solid interactions using time-of-flight secondary ion mass spectrometry (ToF-SIMS). In this work, we illustrate initial results of liquid standards containing uranium using in situ liquid SIMS. Specifically a series of diluted uranium standards used for ICPMS analysis were studied and the limit of detection was estimated. Since the liquid SIMS analysis is almost nondestructive, the same sample can be analyzed by other more destructive approaches afterwards or saved for future references. Consequently, multimodal analysis is possible. Our results demonstrate that in situ liquid SIMS can be used as a new approach to analyze radioactive materials in liquid and slurry forms of relevance to the IAEA safeguards missions.

In situ liquid ToF-SIMS, uranium, limit of detecti↗

Programmable Chemical Gradient Patterns by Soft Grayscale Lithography

A method for fabricating chemical gradients on planar and nonplanar substrates using grayscale lithography is reported. Compliant grayscale amplitude masks are fabricated using a vacuum-assisted microfluidic filling protocol that employs dilutions of a carbon-black-containing polydimethylsiloxane emulsion (bPDMS) within traditional clear PDMS (cPDMS) to create planar, fully self-supporting mask elements. The mask is then placed over a surface functionalized with a hydrophobic coumarin-based photocleavable monolayer, which exposes a polar group upon irradiation. The mask serves to modulate the intensity of incident UV light, thereby controlling the density of molecules cleaved. The resulting molecular-level grayscale patterns are characterized by condensation microscopy and imaging mode time-of-flight secondary-ion mass spectrometry (ToF-SIMS). Due to the inherent flexibility of this technique, the photofuse as well as the gradient patterns can be designed for a wide range of applications; in this paper two proof-of-concept demonstrations are shown. The first utilizes the ability to control the resulting contact angle of the surface for the fabrication of a passive pressure-sensitive microfluidic gating system. The second is a model surface modification process that utilizes the functional groups deprotected during the photocleavage to pattern the deposition of moieties with complementary chemistry. The spatial layout, resolution, and concentration of these covalently linked molecules follow the gradient pattern created by the grayscale mask during exposure. Furthermore, the programmable chemical gradient fabrication scheme presented in this work allows explicit engineering of both surface properties that dictate nonspecific interactions (surface energy, charge, etc.) and functional chemistry necessary for covalent bonding.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Resolving SPARC–HSA binding kinetics with an ultrasensitive photonic sensor based on bound states in the continuum

Secreted protein acidic and rich in cysteine (SPARC) is critical in cell-matrix interactions and tissue remodeling. It influences tumor progression through its affinity for human serum albumin (HSA) - the most abundant plasma protein, which also plays a crucial role in drug delivery. Strong molecular binding leads to a dissociation constant KD in the nanomolar range. Thus, determining KD requires detecting sub-nanomolar concentrations with ultrasensitive methods. This may be crucial for elucidating the nature of SPARC-HSA binding, as their interaction remains a subject of debate. Capturing these interactions accurately requires a platform capable of resolving rapid binding kinetics at extremely low analyte concentrations. In this work, we report on a microfluidics-integrated photonic nanostructure that supports bound states in the continuum (BICs) and is optimized for studying the fast kinetics of high-affinity protein-protein interactions. The unprecedented capability of detecting sub-nanomolar concentrations allows quantifying KD between SPARC and HSA beyond the state of the art. We leverage an all-dielectric photonic crystal slab (PhCS) sustaining two BIC branches arising from gapped Dirac cone dispersion. HSA is covalently immobilized on the PhCS bonded to a PDMS microfluidic chamber. SPARC dissociation is carried out using PBS buffer (pH 7.4), ensuring complete protein release through precise control of the flow rate and continuous spectral monitoring of the BICs. The measured KD=8.2±0.8 nM confirms the strong affinity of SPARC for HSA. This study highlights the potential of BIC-based sensing as a versatile tool for investigating protein interactions. These results also have implications for the optimization of drug delivery systems and cancer treatment strategies.

Albumin↗