Search NASA⌕ Search

SEARCH · Search NASA

Results for “Mobile Measuring System”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

In-situ Inspection of Reflowable-Interface Composite Joints During Cure in an Autoclave

In structural bonds, the interface between adherend and adhesive is nearly two-dimensional making it susceptible to minute quantities of contamination, which can cause weak bonds. Regulatory organizations such as the Federal Aviation Administration (FAA) often require redundant load paths in secondary-bonded, primary-structures to alleviate concerns with bonded performance. Under NASA’s Convergent Aeronautics Solutions (CAS) project, the Adhesive Free Bonding of Composites (AERoBOND) project is investigating reformulated aerospace epoxy-matrix resins to enable reflow and diffusion of the resin at the joint interface during a secondary bonding and cure process. The reflow and intermixing of the matrix resin during assembly can eliminate the material discontinuity at the interface, thereby removing the dependence of bond performance on adhesion at a nearly two-dimensional boundary. AERoBOND process development has evaluated a multitude of parameters including the materials used, the stoichiometric offset of the epoxy resins, time and temperature of cure, and thickness of each ply. Without in-situ process monitoring, the condition of a test article is unknown until mechanical testing is completed. This presentation describes the use of an in-situ ultrasonic inspection system to monitor the joining of two composite parts assembled using the AERoBOND technique. This work quantifies the elimination of the interface by measuring the wave reflection, or lack thereof, at the joint throughout the cure cycle. In addition, the results indicate when reflow and cure of the epoxy resin at the joint occurred. By using the recently developed in-situ inspection with a mobile ultrasonic transducer, localized results can be obtained across a large portion of the joint with high resolution.

Tyler B Hudson↗

In-situ Inspection of Reflowable-Interface Composite Joints During Cure in an Autoclave

In structural bonds, the interface between adherend and adhesive is nearly two-dimensional making it susceptible to minute quantities of contamination, which can cause weak bonds. Regulatory organizations such as the Federal Aviation Administration (FAA) often require redundant load paths in secondary-bonded, primary-structures to alleviate concerns with bonded performance. Under NASA’s Convergent Aeronautics Solutions (CAS) project, the Adhesive Free Bonding of Composites (AERoBOND) project is investigating reformulated aerospace epoxy-matrix resins to enable reflow and diffusion of the resin at the joint interface during a secondary bonding and cure process. The reflow and intermixing of the matrix resin during assembly can eliminate the material discontinuity at the interface, thereby removing the dependence of bond performance on adhesion at a nearly two-dimensional boundary. AERoBOND process development has evaluated a multitude of parameters including the materials used, the stoichiometric offset of the epoxy resins, time and temperature of cure, and thickness of each ply. Without in-situ process monitoring, the condition of a test article is unknown until mechanical testing is completed. This presentation describes the use of an in-situ ultrasonic inspection system to monitor the joining of two composite parts assembled using the AERoBOND technique. This work quantifies the elimination of the interface by measuring the wave reflection, or lack thereof, at the joint throughout the cure cycle. In addition, the results indicate when reflow and cure of the epoxy resin at the joint occurred. By using the recently developed in-situ inspection with a mobile ultrasonic transducer, localized results can be obtained across a large portion of the joint with high resolution.

Tyler B Hudson↗

Cognitive Radio will revolutionize American transportation

Cognitive Radio will revolutionize American transportation. Through smart technology, it will anticipate user needs; detect available bandwidths and frequencies then seamlessly connect vehicles, infrastructures, and consumer devices; and it will support the Department of Transportation IntelliDrive Program, helping researchers, auto manufacturers, and Federal and State officials advance the connectivity of US transportation systems for improved safety, mobility, and environmental conditions. Using cognitive radio, a commercial vehicle will know its driver, onboard freight and destination route. Drivers will save time and resources communicating with automatic toll booths and know ahead of time whether to stop at a weigh station or keep rolling. At accident scenes, cognitive radio sensors on freight and transportation modes can alert emergency personnel and measure on-site, real-time conditions such as a chemical leak. The sensors will connect freight to industry, relaying shipment conditions and new delivery schedules. For industry or military purposes, cognitive radio will enable real-time freight tracking around the globe and its sensory technology can help prevent cargo theft or tampering by alerting shipper and receiver if freight is tampered with while en route. For the average consumer, a vehicle will tailor the transportation experience to the passenger such as delivering age-appropriate movies via satellite. Cognitive radio will enhance transportation safety by continually sensing what is important to the user adapting to its environment and incoming information, and proposing solutions that improve mobility and quality of life.

99 GENERAL AND MISCELLANEOUS↗

High lifetime and mobility CdTe alloys by co-sublimation

The focus of this project was to understand controlled doping of CdTe and CdSe x Te 1-x films using group V element dopants such as nitrogen and arsenic. Using methods such as metal organic precursor injection as well as deposition of absorber with source charge incorporated with desired group V dopant. Using characterization methods such as Secondary Ion Mass Spectroscopy and capacitance vs voltage measurement dopant incorporation and activation was verified. Since our deposition system had CuCl deposition source, this source was permanently removed from the system and vacuum chamber was thoroughly cleaned out. CdSe x Te 1-x grading into CdTe has led to higher device efficiency owing to an improvement in short-circuit current (J SC ) due to its lower band-gap. More device fabrication and characterization was performed in an effort to optimize the lower band-gap CdSe x Te 1-x . This optimization was performed using different co-sublimation method where CdTe and Se were co-sublimated in varying proportion to sweep the band-gap of CdSe x Te 1-x that deposited on the substrate.

14 SOLAR ENERGY↗

Mobile communications satellite antenna flight experiment definition

Results of a NASA-sponsored study to determine the technical feasibility and cost of a Shuttle-based flight experiment specifically intended for the MSAT commercial user community are presented. The experiment will include demonstrations of technology in the areas of radio frequency, sensing and control, and structures. The results of the structural subsystem study summarized here include experiment objective and technical approach, experiment structural description, structure/environment interactions, structural characterization, thermal characterization, structural measurement system, and experiment functional description.

Freeland, Robert E.↗

Long-Lived Charge Separation at Heterojunctions between Semiconducting Single-Walled Carbon Nanotubes and Perylene Diimide Electron Acceptors

Nonfullerene electron acceptors have facilitated a recent surge in the efficiencies of organic solar cells, although fundamental studies of the nature of exciton dissociation at interfaces with nonfullerene electron acceptors are still relatively sparse. Semiconducting single-walled carbon nanotubes (s-SWCNTs), unique one-dimensional electron donors with molecule-like absorption and highly mobile charges, provide a model system for studying interfacial exciton dissociation. Here, we investigate excited-state photodynamics at the heterojunction between (6,5) s-SWCNTs and two perylene diimide (PDI)-based electron acceptors. Each of the PDI-based acceptors, hPDI2-pyr-hPDI2 and Trip-hPDI2, is deposited onto (6,5) s-SWCNT films to form a heterojunction bilayer. Transient absorption measurements demonstrate that photoinduced hole/electron transfer occurs at the photoexcited bilayer interfaces, producing long-lived separated charges with lifetimes exceeding 1.0 us. Both exciton dissociation and charge recombination occur more slowly for the hPDI2-pyr-hPDI2 bilayer than for the Trip-hPDI2 bilayer. To explain such differences, we discuss the potential roles of the thermodynamic charge transfer driving force available at each interface and the different molecular structure and intermolecular interactions of PDI-based acceptors. As a result, detailed photophysical analysis of these model systems can develop the fundamental understanding of exciton dissociation between organic electron donors and nonfullerene acceptors, which has not been systematically studied.

14 SOLAR ENERGY↗

FY24 Progress Report on Viscosity and Thermal Conductivity Measurements of Nuclear Industry Relevant Chloride Salts: An Experimental and Computational Study

As presented in this report, experimental and computational techniques were performed to assess the viscosity and thermal conductivity of key alkali and actinide chloride mixtures for molten salt reactor developers. These mixtures were pure LiCl, NaCl-KCl, LiCl-NaCl, LiCl-KCl, LiCl-NaCl-KCl, and NaCl-UCl 3 . Experimental measurements of viscosity were performed with a rolling ball viscometer, whereas experimental measurements of thermal conductivity were performed with a variable gap apparatus. Additional benchmarking work was performed using both property measurement systems to prepare for x-ray radiography in stainless-steel crucibles for viscosity and to ensure that calibration methods were accurate for thermal conductivity before assessing the NaCl-UCl 3 system. Validation data for the NaCl-UCl 3 in literature are minimal. Details on the calibration methods, salt measurement processes, and sources of error and uncertainty are discussed in detail for both property measurements. The computational methods described herein involved ab-initio molecular dynamics (AIMD) calculations using CP2K. The calculations were performed for the LiCl-KCl-NaCl and NaCl-UCl 3 systems. These calculations not only provided thermophysical property estimations for comparison to experimental data, but they also allowed for the determination of diffusion coefficients, coordination numbers, and radial distribution functions to provide insight into ion mobility and local coordination environments, which is linked to macroscopic property trends.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Mini-cavity-dumped laser

Lasers for use in high precision satellite ranging systems consist typically of an oscillator followed by several amplifier stages. While the shortest optical pulses are achieved by using a mode locked oscillator, such an oscillator is incompatible with the compact design needed in future, highly mobile systems. The laser oscillator achieves pulse lengths approaching those obtainable by mode locking, but in a much more compact and stable design. The oscillator uses two LiNbO3 Pockels cells inside the resonator. One Q-switches the oscillator, and the other is used in a pulse slicing scheme to cavity dump a portion of the circulating optical energy. The length of the optical output pulse measured at 425 + or - 50 picoseconds.

Reed, E.↗

Navigating Urban Mobility: Evaluating Infrastructure Strategies for Enhanced Energy-Efficient Access for Micromobility

Cities and communities continue to expand pedestrian and bicycle infrastructure as part of their sustainable mobility and post-pandemic recovery plans. However, the emergence of micro-mobility (e.g., electric bicycles) has created new challenges for urban transport planning. As the popularity of micro-mobility modes has grown, so have safety concerns due to rising injuries, thus challenging many cities to come up with regulatory measures that enable efficient access while minimizing negative impacts from micro-mobility. Leveraging the Open-Source Tool (Mobility Energy Productivity metric), powered by an open-source dataset (OpenStreetMap), and enhanced through the incorporation of perceived discomfort (level-of-traffic stress), this research study focuses on evaluating the accessibility implications of infrastructure planning and regulatory measures for micro-mobility. Five scenarios pertaining to level of traffic stress, sidewalk access, traffic calming, and bike lane coverage were tested in the Denver-Aurora region in Colorado. Maximum improvements in energy-efficient access are realized when allowing sidewalks for micro-mobility use. Cities and planning agencies could leverage this information to assess sidewalk use policies for micro-mobility, while ensuring pedestrian safety and ADA access. Results indicate that expansion of bicycle lane coverage yields 11% accessibility benefits for micro-mobility compared to implementing traffic calming measures yielding 3% accessibility improvements. Further, it was observed most of the population in the Denver-Aurora region is experiencing lower accessibility in-part due to presence of a high-stress connections in the network. Although not generalizable, the use of open-source data and access calculation methodology, make this analysis reproducible and transferable to other locations.

ADVANCED PROPULSION SYSTEMS↗

Validation testing of the Canberra mobile Feed Roll Assay system - 15404

Japanese farmers grow various grasses as feed for cattle. These are rolled up and sealed for future use. Canberra has created a special truck to monitor these Feed Rolls, called 'Feed Roll Assay System [FRAS]'. On the bed of the truck is the shield containing a large NaI detector. The detector is 3x5x16'' in size, the same size as used in the Canberra FastScan Whole Body Counter. The detector is also LED-stabilized, to keep the gain constant under the wide range of temperature variations expected for this outdoor measurement instrument. The Canberra Osprey digital MCA is connected to the detector. The detector and the MCA are housed in a water proof box, which is surrounded on the bottom and all sides by a 15 cm thick steel shield. A portion of the shield at the top is open where the detector can view the Feed Rolls placed there. A single ethernet cable goes to a laptop PC which provides power to the MCA and detector, and also transmits the signal to the PC. The system was calibrated using MCNP for a variety of different densities, and Feed Roll sizes. The Japanese version of the Canberra Genie software is used to analyze the spectra and compute the Bq/kg concentration of the Feed Roll. The shielding is sufficient so that at a 5 uSv/hr background dose rate, no Cs-137 or Cs-134 peaks were detected in a 1 hour count. Measurements were performed in 0.2 uSv/hr dose rate, using uncontaminated Feed Rolls at various counting times. The MDA for Cs-137 was 11.9 Bq/kg at 30 seconds, 8.2 Bq/kg for 60 seconds, and 1.1 Bq/kg at 3600 seconds count time. The relative measurement uncertainty of the FRAS measurements was 9.4 to 13%, as compared to assays of samples extracted [30-45%] and in-situ Ge measurements [6.0 - 7.1%]. The FRAS measurement results have considerably better precision than measurements of samples extracted from the Feed Rolls, and are much faster than the in-situ Ge measurements and have just about the same uncertainty. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Usability Evaluation of Fleet Management Interface for High Density Vertiplex Environments

To meet the rising demand for an Advanced Air Mobility (i.e. urban and rural unmanned aircraft systems) ecosystem, NASA Aeronautics Research Mission Directorate (ARMD) is hosting a series of simulations and flight tests under the High Density Vertiplex sub-project (HDV). HDV aims to develop an integrated automation architecture to support terminal area flight operations. The HDV simulations and flight tests address safety, integration, and operational challenges, while integrated systems and software demonstrate design readiness, robustness, and interoperability. During the initial HDV simulation in 2021, a prototype traffic management tool developed by NASA called Fleet Management Interface (FMI) was tested. FMI was designed to introduce an advanced level of human-automation interaction to aid both Ground Control Station Operators (GCSOs) and Fleet Managers (FMs) in remotely managing flights under their ownership. In a human-in-the-loop simulation, a usability study was conducted with FMI to identify optimal approaches for displaying information for human operators using subjective measures of usability, workload, situation awareness, risk, and trust, along with qualitative feedback. This study consisted of task analysis in which GCSO and FM subjects used an Urban Air Mobility (UAM) environment to develop and execute a plan for two different traffic scenarios of remotely controlled vehicles. In each scenario, a controlled vehicle completed a takeoff, active flight, and landing sequence while automated traffic flew in the background at a rate of 20 operations per hour. In the first scenario, the controlled vehicle flew a nominal route with takeoff and landing at the same vertiport. In the second scenario, the controlled vehicle started on the nominal route, then diverted to an unplanned location mid-flight. Results showed that self-reported performance, usability, trust, and situation awareness ratings of FMI were moderately to strongly high. There were small differences between scenarios, with Scenario 2 being perceived as more unstable, complex, variable, risky, and potentially harmful than Scenario 1. Furthermore, participants described improvements that could be made to create a better user experience. For example, users would like greater configurability of the interface based on their personal information requirements, and they would like the opportunity to review routes before assigning them. The results from this study will inform future development of the FMI with the end goal of creating a reference automation tool for airspace management procedures in AAM. The FMI could be introduced as a potential way to reduce dependency on traditional air navigation services through increased automation in high density vertiplex environments.

vertiplex↗

The separated electric and magnetic field responses of luminescent bacteria exposed to pulsed microwave irradiation

Electromagnetic fields (EMFs) are ubiquitous in the digital world we inhabit, with microwave and millimetre wave sources of non-ionizing radiation employed extensively in electronics and communications, e.g., in mobile phones and Wi-Fi. Indeed, the advent of 5G systems and the “internet of things” is likely to lead to massive densification of wireless networks. Whilst the thermal effects of EMFs on biological systems are well characterised, their putative non-thermal effects remain a controversial subject. Here, we use the bioluminescent marine bacterium, Vibrio fischeri, to monitor the effects of pulsed microwave electromagnetic fields, of nominal frequency 2.5 GHz, on light emission. Separated electric and magnetic field effects were investigated using a resonant microwave cavity, within which the maxima of each field are separated. For pulsed electric field exposure, the bacteria gave reproducible responses and recovery in light emission. At the lowest pulsed duty cycle (1.25%) and after short durations (100 ms) of exposure to the electric field at power levels of 4.5 W rms, we observed an initial stimulation of bioluminescence, whereas successive microwave pulses became inhibitory. Much of this behaviour is due to thermal effects, as the bacterial light output is very sensitive to the local temperature. Conversely, magnetic field exposure gave no measurable short-term responses even at the highest power levels of 32 W rms. Thus, we were able to detect, de-convolute, and evaluate independently the effects of separated electric and magnetic fields on exposure of a luminescent biological system to microwave irradiation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Evaluating Connected and Automated Vehicles in Co-Simulation Environment of Traffic Microsimulation and Vehicle Dynamics

Connected and automated vehicles (CAVs) have the potential to improve many aspects of the current transportation systems such as safety, mobility, and energy efficiency. In order to evaluate the benefits and impacts of a CAV, the CAV control algorithm is typically implemented on vehicles simulated in a traffic microsimulation environment. However, traffic microsimulation usually lacks detailed vehicle and powertrain dynamics, making it challenging to fully understand how a CAV control algorithm will perform and respond on an actual vehicle. Whether the same benefits measured in the simulation will also be observed in real-world remains an open question. One potential approach to fill in this gap is to conduct a co-simulation of traffic microsimulation with detailed vehicle and powertrain dynamics models, often developed in MATLAB Simulink. However, current microsimulation tools such as VISSIM and SUMO do not have a ready-to-use interface for co-simulation with vehicle dynamics and Simulink. Also, even if such an interface exists, it will be tool-specific, making it challenging to shift from one tool to another or test CAV controls in different tools. There are needs for tool-agnostic co-simulation as different microsimulation tools have their pros and cons, and researchers often need to use different tools based on the purposes of the simulation, project needs, and applications. In this work, Flexible Interface for X-in-the-loop Simulation (FIXS) is developed that can support the co-simulation of microsimulation, CAV control algorithm, and vehicle dynamics model in Simulink. Enabled by the FIXS, the benefit and performance of a CAV control algorithm can be better understood with the consideration of vehicle responses and dynamics. The connection to VISSIM and SUMO is handled internally by the interface, and users can easily switch tools by changing a configuration file. The co-simulation capability is demonstrated for a VISSIM eco-approach and departure CAV scenario and a SUMO cooperative merging scenario for both a passenger CAV and a class 8 heavy-duty connected and automated trucks.

Shao, Yunli↗

Inspecting the minefield and residual explosives by fast neutron activation method

As an upgrade of a robotic mobile system for antipersonnel land-mine clearance, a fast neutron probe has been considered for the detection of mines and explosive residues. Laboratory tests were made by using the 14 MeV 6 x 10{sup 7} neutrons/sec beam with the associated alpha particle detection and with a LaBr{sub 3} gamma ray detector. Simulant of the anti-personal mine was used as a target. Several measurements were made with the target buried into the soil at different depths. For each depth minimal time measurement was estimated for false negative 0.4 % and false positive equal to 10 %. Tests showed that is possible to detect buried land-mine as well as residual explosives; however, in order to reach the optimal speed of 10 cm/s for de-mining vehicle it is necessarily to use several sealed tube neutron generators and few tens of LaBr{sub 3} gamma ray detectors. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Insights from Femtosecond Transient Absorption Spectroscopy into the Structure–Function Relationship of Glyceline Deep Eutectic Solvents

This study aimed to determine the structure–function relationship (SFR) for ChCl–glycerol mixtures, a deep eutectic solvent (DES), by investigating their microscopic solvation dynamics and how it relates to their macroscopic properties across varying concentrations of ChCl. Femtosecond transient absorption (fs-TA) spectroscopy revealed two distinct solvation dynamics time constants: τ 1 , governed by glycerol–glycerol interactions, and τ 2 , dominated by the choline response. The τ 2 minimum at 25–30 mol % ChCl closely aligned with the eutectic composition (~33.33 mol % ChCl), where the glycerol network was the most organized and the choline ions exhibited the fastest relaxation. The viscosity decreased sharply up to ~25 mol % ChCl and then plateaued, while the conductivity increased monotonically with ChCl concentration, reflecting enhanced ionic mobility. The density decreased with both increasing ChCl concentration and temperature, indicating disrupted hydrogen bonding and reduced molecular packing. The polarity, measured using betaine-30 (B30) and the E T (30) polarity scale, increased steeply up to approximately 25 mol % ChCl before reaching a plateau. These findings identified the eutectic composition as the optimal concentration range for balancing stability, fluidity, conductivity, and enhanced dynamics within the glycerol system.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Cosmic background radiation anisotropy at degree angular scales - Further results from the South Pole

We report further results from the University of California at Santa Barbara program to measure anisotropy in the cosmic background radiation at angular scales near 1 deg, an angular range corresponding to the largest scales where structure is observed. A 30 GHz high electron mobility transistor amplifier-based detector was coupled to the Advanced Cosmic Microwave Explorer, a 1 m off-axis Gregorian telescope. We present data that represent 64 of the total of 500 hr acquired with this system during the 1990-1991 season. The data have a statistical error of 13.5/micro-K/pixel. These are the smallest error bars of any data set of this type published to date. The data contain a significant signal with a maximum likelihood Delta T/T roughly 1 x 10 exp -5. The spectrum of the signal seen in slightly less than 2 sigma away from the thermal spectrum expected of primordial fluctuations in the cosmic background radiation. If the source of the fluctuations is primordial, then the data are consistent with cold dark matter scenarios when normalized to the large-scale anisotropy observed by COBE, while if the origin of the signal is foreground emission or another form of contaminant then the data are marginally inconsistent with standard cold dark matter models. In either case, the data are sufficiently sensitive to provide a crucial test of many models.

Schuster, Jeffrey↗

Measurements of Aerosols, Radiation, and Clouds over the Southern Ocean (MARCUS) Field Campaign Report

The Southern Ocean (SO) is the stormiest place on earth, buffeted by winds and waves that circle the ice of Antarctica, sheathed in clouds that mantle a dynamic ocean with rich ecosystems. The remote and usually pristine environment, typically removed from anthropogenic and natural continental aerosol sources, makes the SO unique for examining cloud-aerosol interactions for liquid and ice clouds, and the role of primary and secondary marine biogenic aerosols and sea salt. There is strong seasonality in aerosol sources and sinks over the SO that are poorly understood. Weather and climate models are challenged by uncertainties and biases in the simulation of SO clouds, aerosols, precipitation, and radiative transfer that trace to poor physical understanding of these processes, and by cloud feedbacks (e.g., phase changes) in response to warming. Models almost universally underestimate sunlight reflected by near-surface cloud, particularly in the cold sector of cyclonic storm systems, and this may be due to difficulties in representing pervasive supercooled and mixed-phase boundary-layer (BL) clouds. The Southern Ocean Clouds Radiation Transport Aerosol Transport Experimental Study (SOCRATES) white paper (Marchand et al. 2014) describes the motivation, scientific themes, and testable hypotheses that led to a multi-agency and international measurement campaign to study clouds, aerosols, and the air-sea interface over the SO. As a separate project within this international umbrella, the Measurement of Aerosols, Radiation, and Clouds over the Southern Ocean (MARCUS) field program was conducted between 29 October 2017 and 25 March 2018. During MARCUS, instruments from the U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) user facility’s second Mobile Facility (AMF2) were installed on the Australian icebreaker Aurora Australis as it made resupply missions from Hobart, Tasmania to the Australian Antarctic stations of Casey, Mawson, and Davis, as well as Macquarie Island. Figure 1 shows the voyages conducted during MARCUS. The MARCUS data are unique in that they are the only set of data in the broader international effort that a) acquired comprehensive observations of clouds, aerosols, and radiation south of 60°S, and b) acquired measurements across the full SO latitudinal range in the spring and fall seasons.

atmospheric emitted radiance interferometer↗

MONICA: a compact, portable dual gamma camera system for mouse whole-body imaging

Introduction We describe a compact, portable dual-gamma camera system (named "MONICA" for MObile Nuclear Imaging CAmeras) for visualizing and analyzing the whole-body biodistribution of putative diagnostic and therapeutic single photon emitting radiotracers in animals the size of mice. Methods Two identical, miniature pixelated NaI(Tl) gamma cameras were fabricated and installed ?looking up? through the tabletop of a compact portable cart. Mice are placed directly on the tabletop for imaging. Camera imaging performance was evaluated with phantoms and field performance was evaluated in a weeklong In-111 imaging study performed in a mouse tumor xenograft model. Results Tc-99m performance measurements, using a photopeak energy window of 140 keV?10%, yielded the following results: spatial resolution (FWHM at 1 cm), 2.2 mm; sensitivity, 149 cps (counts per seconds)/MBq (5.5 cps/μCi); energy resolution (FWHM, full width at half maximum), 10.8%; count rate linearity (count rate vs. activity), r2=0.99 for 0?185 MBq (0?5 mCi) in the field of view (FOV); spatial uniformity, <3% count rate variation across the FOV. Tumor and whole-body distributions of the In-111 agent were well visualized in all animals in 5-min images acquired throughout the 168-h study period. Conclusion Performance measurements indicate that MONICA is well suited to whole-body single photon mouse imaging. The field study suggests that inter-device communications and user-oriented interfaces included in the MONICA design facilitate use of the system in practice. We believe that MONICA may be particularly useful early in the (cancer) drug development cycle where basic whole-body biodistribution data can direct future development of the agent under study and where logistical factors, e.g., limited imaging space, portability and, potentially, cost are important.

62 RADIOLOGY AND NUCLEAR MEDICINE↗