Search NASA⌕ Search

SEARCH · Search NASA

Results for “Neutron Source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Moderator design studies for a new neutron reference source based on the $\mathrm{D}$–$\mathrm{T}$ fusion reaction

The radioactive isotope Californium-252 ( 252 Cf) is relied upon internationally as a neutron calibration source for ionizing radiation dosimetry because of its high specific activity. The source may be placed within a heavy-water (D 2 O) moderating sphere to produce a softened spectrum representative of neutron fields common to commercial nuclear power plant environments, among others. Due to termination of the U.S. Department of Energy loan/lease program in 2012, the expense of obtaining 252 Cf sources has undergone a significant increase, rendering high output sources largely unattainable. On the other hand, the use of neutron generators in research and industry applications has increased dramatically in recent years. Neutron generators based on deuterium-tritium (D-T) fusion reaction provide high neutron fluence rates and, therefore, could possibly be used as a replacement for 252 Cf. To be viable, the 14.6 MeV D-T output spectrum must be significantly moderated to approximate common workplace environments. Here this paper presents the results of an effort to select appropriate moderating materials and design a configuration to reshape the primary neutron field toward a spectrum approaching that from a nuclear power plant workplace. A series of Monte-Carlo (MCNP) simulations of single layer high- and low-Z materials are used to identify initial candidate moderators. Candidates are refined through a similar series of simulations involving combinations of 2 to 5 different materials. The simulated energy distribution using these candidate moderators are rated in comparison to a target spectrum. Other properties, such as fluence preservation and/or enhancement, prompt gamma production and other characteristics are also considered.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

A Survey of Students from the National School on Neutron and X-ray Scattering: Communication Habits and Preferences

Oak Ridge National Laboratory (ORNL) offers the scientific community unique access to two types of world-class neutron sources at a single site - the Spallation Neutron Source (SNS) and the High Flux Isotope Reactor (HFIR). The 85-MW HFIR provides one of the highest steady-state neutron fluxes of any research reactor in the world. And the SNS is one of the world's most intense pulse neutron beams. Management of these resources is the responsibility of the Neutron Sciences Directorate (NScD). NScD started conducting the National School on Neutron and X-ray Scattering (NXS) in conjunction with the Advanced Photon Source (APS) at Argonne National Laboratory in 2007. This survey was conducted to determine the most effective ways to reach students with information about what SNS and HFIR offer the scientific community, including content and communication vehicles. The emphasis is on gaining insights into compelling messages and the most effective channels, e.g., Web sites and social media, for communicating with students about neutron science The survey was conducted in two phases using a classic qualitative investigation to confirm language and content followed by a survey designed to quantify issues, assumptions, and working hypotheses. Phase I consisted of a focus group in late June 2010 with students attending NXS. The primary intent of the group was to inform development of an online survey. Phase two consisted of an online survey that was developed and pre-tested in July 2010 and launched on August 9, 2010 and remained in the field until September 9, 2010. The survey achieved an overall response rate of 48% for a total of 157 completions. The objective of this study is to determine the most effective ways to reach students with information about what SNS and HFIR offer the scientific community, including content and communication vehicles. The emphasis is on gaining insights into compelling messages and the most effective channels, e.g., Web sites, social media, for communicating with students about neutron science.

43 PARTICLE ACCELERATORS↗

Applied radiation tags for warhead dismantlement transparency

Here, this study explores the feasibility of applying radiation tags as a Chain of Custody tool to confirm the dismantlement of individual warheads by investigating time dependent emissions from special nuclear material. Precedents of photon and neutron sources that have been used to irradiate warhead components are presented. Measurements of irradiated Highly Enriched Uranium (HEU) are used to benchmark simulations with the CINDER90 library for MCNP. Delayed gamma emissions are simulated as a function of time since irradiation of moderated HEU and Weapons Grade Plutonium with photon and neutron sources. Models of commercial 9 MV and 15 MV linacs were found to induce ~10 9 fissions/g and ~10 11 fissions/g, respectively, creating 3 to 4 orders of magnitude more delayed gammas than neutron sources, modeled at 10 10 n/s. However, a DT neutron source was found to induce sufficient fissions, ~10 7 fissions/g, to create quantifiable signatures relative to intrinsic emissions. Applied radiation tagging is determined to be technically feasible, but its operational context and practical implementation requires significant development.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Exploiting fission chain reaction dynamics to image fissile materials

Radiation imaging is one potential method to verify nuclear weapons dismantlement. In this work, we present a method to discriminate between non-multiplying and multiplying neutron sources using a neutron coded aperture imaging system. This method applies time-correlated pulse-height (TCPH) analysis to identify neutrons in fission chain reactions and recreate images using only these events. This analysis was applied to measurements of weapons-grade plutonium (WGPu) metal and 252 Cf performed at the Nevada National Security Site (NNSS) Device Assembly Facility in July 2015. The results demonstrate it is possible to eliminate the non-fissile 252 Cf source from the image while preserving the fissile WGPu source. TCPH analysis was also applied to additional scenes in which the WGPu and 252 Cf sources were measured individually. The results of these separate measurements further demonstrate the ability to remove the non-fissile 252 Cf source and retain the fissile WGPu source. Simulations performed using MCNPX-PoliMi indicate that in a one hour measurement, hollow WGPu spheres are retained at a 1σ level for neutron multiplications M ≃ 2:7 and above. This work has potential application to dismantlement verification where it may be valuable to verify that all neutron sources in an image are multiplying.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

What happened to the moon? A lunar history mission using neutrons

The ages of lunar rocks can be determined using the {sup 40}Ar -{sup 39}Ar technique that can be used in-situ on the moon if a neutron source, a noble gas mass spectrometer and a gas extraction and purification system are brought to the lunar surface. A possible instrument for such a task is ISAGE, which combines a strong {sup 252}Cf neutron source and a compact spectrometer for in-situ dating of e.g. the South Pole Aitken impact basin or the potentially very young basalts south of the Aristachus Plateau. In this paper, the design of the neutron source will be discussed. The source is assumed to be a hollow sphere surrounded by a reflector, a geometry that provides a very homogeneous flux at the irradiation position inside the sphere. The optimal source geometry depending on the experimental conditions, the costs of transportation for the reflector and the costs of the source itself are calculated. A minimum {sup 252}Cf mass of 1.5 mg is determined. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

Neutron Capture Gamma-Ray Libraries for Nuclear Applications

The neutron capture reaction is useful in identifying and analyzing the gamma-ray spectrum from an unknown assembly as it gives unambiguous information on its composition. This can be done passively or actively where an external neutron source is used to probe an unknown assembly. There are known capture gamma-ray data gaps in the ENDF libraries used by transport codes for various nuclear applications. The Evaluated Gamma-ray Activation file (EGAF) is a new thermal neutron capture database of discrete line spectra and cross sections for over 260 isotopes that was developed as part of an IAEA Coordinated Research Project. EGAF is being used to improve the capture gamma production in ENDF libraries. For medium to heavy nuclei the quasi continuum contribution to the gamma cascades is not experimentally resolved. The continuum contains up to 90% of all the decay energy and is modeled here with the statistical nuclear structure code DICEBOX. This code also provides a consistency check of the level scheme nuclear structure evaluation. The calculated continuum is of sufficient accuracy to include in the ENDF libraries. This analysis also determines new total thermal capture cross sections and provides an improved RIPL database. For higher energy neutron capture there is less experimental data available making benchmarking of the modeling codes more difficult. We are investigating the capture spectra from higher energy neutrons experimentally using surrogate reactions and modeling this with Hauser-Feshbach codes. This can then be used to benchmark CASINO, a version of DICEBOX modified for neutron capture at higher energy. This can be used to simulate spectra from neutron capture at incident neutron energies up to 20 MeV to improve the gamma-ray spectrum in neutron data libraries used for transport modeling of unknown assemblies.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The Axisymmetric Tandem Mirror: A Magnetic Mirror Concept Game Changer Magnet Mirror Status Study Group

Experimental results, theory and innovative ideas now point with increased confidence to the possibility of a Gas Dynamic Trap (GDT) neutron source which would be on the path to an attractively simple Axisymmetric Tandem Mirror (ATM) power plant. Although magnetic mirror research was terminated in the US 20 years ago, experiments continued in Japan (Gamma 10) and Russia (GDT), with a very small US effort. This research has now yielded data, increased understanding, and generated ideas resulting in the new concepts described here. Early mirror research was carried out with circular axisymmetric magnets. These plasmas were MHD unstable due to the unfavorable magnetic curvature near the mid-plane. Then the minimum-B concept emerged in which the field line curvature was everywhere favorable and the plasma was situated in a MHD stable magnetic well (70% average beta in 2XII-B). The Ioffe-bar or baseball-coil became the standard for over 40 years. In the 1980's, driven by success with minimum-B stabilization and the control of ion cyclotron instabilities in PR6 and 2XII-B, mirrors were viewed as a potentially attractive concept with near-term advantages as a lower Q neutron source for applications such as a hybrid fission fuel factory or toxic waste burner. However there are down sides to the minimum-B geometry: coil construction is complex; restraining magnetic forces limit field strength and mirror ratios. Furthermore, the magnetic field lines have geodesic curvature which introduces resonant and neoclassical radial transport as observed in early tandem mirror experiments. So what now leads us to think that simple axisymmetric mirror plasmas can be stable? The Russian GDT experiment achieves on-axis 60% beta by peaking of the kinetic plasma pressure near the mirror throat (where the curvature is favorable) to counter-balance the average unfavorable mid-plane curvature. Then a modest augmentation of plasma pressure in the expander results in stability. The GDT experiments have confirmed the physics of effluent plasma stabilization predicted by theory. The plasma had a mean ion energy of 10 keV and a density of 5e19m-3. If successful, the axisymmetric tandem mirror extension of the GDT idea could lead to a Q {approx} 10 power plant of modest size and would yield important applications at lower Q. In addition to the GDT method, there are four other ways to augment stability that have been demonstrated; including: plasma rotation (MCX), diverter coils (Tara), pondermotive (Phaedrus & Tara), and end wall funnel shape (Nizhni Novgorod). There are also 5 stabilization techniques predicted, but not yet demonstrated: expander kinetic pressure (KSTM-Post), Pulsed ECH Dynamic Stabilization (Post), wall stabilization (Berk), non-paraxial end mirrors (Ryutov), and cusp ends (Kesner). While these options should be examined further together with conceptual engineering designs. Physics issues that need further analysis include: electron confinement, MHD and trapped particle modes, analysis of micro stability, radial transport, evaluation and optimization of Q, and the plasma density needed to bridge to the expansion-region. While promising all should be examined through increased theory effort, university-scale experiments, and through increased international collaboration with the substantial facilities in Russia and Japan The conventional wisdom of magnetic mirrors was that they would never work as a fusion concept for a number of reasons. This conventional wisdom is most probably all wrong or not applicable, especially for applications such as low Q (DT Neutron Source) aimed at materials testing or for a Q {approx} 3-5 fusion neutron source applied to destroying actinides in fission waste and breeding of fissile fuel.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

INITIAL EVALUATION OF A PULSED WHITE SPECTRUM NEUTRON GENERATOR FOR EXPLOSIVE DETECTION

Successful explosive material detection in luggage and similar sized containers is acritical issue in securing the safety of all airline passengers. Tensor Technology Inc. has recently developed a methodology that will detect explosive compounds with pulsed fast neutron transmission spectroscopy. In this scheme, tritium beams will be used to generate neutrons with a broad energy spectrum as governed by the T(t,2n)4He fission reaction that produces 0-9 MeV neutrons. Lawrence Berkeley National Laboratory (LBNL), in collaboration with Tensor Technology Inc., has designedand fabricated a pulsed white-spectrum neutron source for this application. The specifications of the neutron source are demanding and stringent due to the requirements of high yield and fast pulsing neutron emission, and sealed tube, tritium operation. In a unique co-axial geometry, the ion source uses ten parallel rf induction antennas to externally couple power into a toroidal discharge chamber. There are 20 ion beam extraction slits and 3 concentric electrode rings to shape and accelerate the ion beam into a titanium cone target. Fast neutron pulses are created by using a set ofparallel-plate deflectors switching between +-1500 volts and deflecting the ion beams across a narrow slit. The generator is expected to achieve 5 ns neutron pulses at tritium ion beam energies between 80 - 120 kV. First experiments demonstrated ion source operation and successful beam pulsing.

43 PARTICLE ACCELERATORS↗

Design Challenges and Performance of Nested Neutron Mirrors for Microfocusing on SNAP

Kirkpatrick-Baez (KB) neutron supermirrors can efficiently focus polychromatic neutron beams to micrometre dimensions. The ultimate size is determined mainly by the perfection of the mirrors and by the size of the beam needed to have sufficient experimental signal. Nested or Montel KB mirrors can collect ~2.6 times more beam than standard sequential KB optics, but require good figure perfection at the edge of one mirror. This paper describes the characterization of the figure errors over the important reflective portions of the two mirrors needed for a Montel focusing pair. The measurements are placed in context with theoretical predictions and are used to predict mirror focusing performance. Strategies to improve on the focusing of this class of optics are suggested and early results from these mirrors installed on the Spallation Neutrons at Pressure (SNAP) Beamline 3 at the Spallation Neutron Source (SNS) at Oak Ridge are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Absolute calibration of microfission chamber in JT-60U

We have conducted calibrations of a microfission chamber, which was installed between the vacuum vessel and the toroidal field coils, by both a Cf-252 neutron source and real deuterium plasmas in JT-60U. The detector employs both pulse counting and Campbell (mean square voltage) modes in the electronics to cover a wide dynamic range of the neutron source strength. The pulse counting and Campbell modes were calibrated by Cf-252 and deuterium plasmas, respectively. Point efficiencies, counts per neutron from a point at a single angle, were measured for 27 locations of the neutron point source in toroidal scan. The efficiencies were influenced by the various components such as the vacuum vessel, port, and graphite tiles. The point efficiencies can be integrated and averaged with angle to provide toroidal line efficiencies. The line efficiencies of the microfission chamber and the nearest neutron monitor of the U-235 fission chamber were 5.38x10{sup -9} and 1.77x10{sup -8}, respectively. Then the calibration for the Campbell mode was also performed by using a real deuterium plasma. The detection efficiency in the Campbell mode was about three-tenths of that of the nearest neutron monitor, which is consistent with the calibration result obtained by using a Cf-252 neutron source for pulse counting mode.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Revised SNAP III Training Manual

The Shielded Neutron Assay Probe (SNAP) technique was developed to determine the leakage neutron source strength of a radioactive object. The original system consisted of an Eberline TM Mini-scaler and discrete neutron detector. The system was operated by obtaining the count rate with the Eberline TM instrument, determining the absolute efficiency from a graph, and calculating the neutron source strength by hand. In 2003 the SNAP III, shown in Figure 1, was designed and built. It required the operator to position the SNAP, and then measure the source-to-detector and detectorto- reflector distances. Next the operator entered the distance measurements and started the data acquisition. The SNAP acquired the required count rate and then calculated and displayed the leakage neutron source strength (NSS). The original design of the SNAP III is described in SNAP III Training Manual (ER-TRN-PLN-0258, Rev. 0, January 2004, prepared by William Baird) This report describes some changes that have been made to the SNAP III. One important change is the addition of a LEMO connector to provide neutron detection output pulses for input to the MC-15. This feature is useful in active interrogation with a neutron generator because the MC-15 has the capability to only record data when it is not gated off by a pulse from the neutron generator. This avoids recording of a lot of data during the generator pulses that are not useful. Another change was the replacement of the infrared RS-232 serial communication output by a similar output via a 4-pin LEMO connector. The current document includes a more complete explanation of how to estimate the amount of moderation around a neutron-emitting source.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ion Source Development at the SNS

The Spallation Neutron Source (SNS) now routinely operates near 1 MW of beam power on target with a highly-persistent ~38 mA peak current in the linac and an availability of ~90%. The ~1 ms-long, 60 Hz, ~50 mA H- beam pulses are extracted from a Cs-enhanced, multi-cusp, RF-driven, internal-antenna ion source. An electrostatic LEBT (Low Energy Beam Transport) focuses the 65 kV beam into the RFQ accelerator. The ion source and LEBT have normally a combined availability of ~99%. Although much progress has been made over the last years to achieve this level of availability further improvements are desirable. Failures of the internal antenna and occasionally impaired electron dump insulators require several source replacements per year. An attempt to overcome the antenna issues with an AlN external antenna source early in 2009 had to be terminated due to availability issues. This report provides a comprehensive review of the design, experimental history, status, and description of recently updated components and future plans for this ion source. The mechanical design for improved electron dump vacuum feedthroughs is also presented, which is compatible with the baseline and both external antenna ion sources.

43 PARTICLE ACCELERATORS↗

Time series anomaly detection in power electronics signals with recurrent and ConvLSTM autoencoders

The anomalies in the high voltage converter modulator (HVCM) remain a major down time for the spallation neutron source facility, that delivers the most intense neutron beam in the world for scientific materials research. In this work, we propose neural network architectures based on Recurrent AutoEncoders (RAE) to detect anomalies ahead of time in the power signals coming from the HVCM. Bi-directional gated recurrent unit, bi-directional long-short term memory (LSTM), and convolutional LSTM (ConvLSTM) are developed, trained, and tested using real experimental signals from the HVCM module. The results show a good performance of the proposed RAE models, achieving precision up to 91%, recall up to 88%, false omission rate as low as 20% (i.e. 80% of the anomalies were detected), and area under the ROC curve up to 0.9. The three RAE models provide very comparable performance, with LSTM showing slightly better performance than GRU and ConvLSTM. The RAE models are benchmarked against other anomaly detection methods, including isolation forest, support vector machine, local outlier factor, feedforward and convolutional autoencoders, and others; showing a better performance. Here, the results of this study demonstrate the promising potential of RAE in anomaly detection for real-world power systems, and for increasing the reliability of the HVCM modules in the spallation neutron source.

42 ENGINEERING↗

Neutron-deuteron analyzing power data at 19.0 MeV

Measurements of neutron-deuteron (n-d) analyzing power A{sub y}(theta) at E{sub n}=19.0 MeV are reported at 16 angles from theta{sub c.m.}=46.7 to 152.0 deg. The objective of the experiment is to better characterize the discrepancies between n-d data and the predictions of three-nucleon calculations for neutron energies above 16.0 MeV. The experiment used a shielded neutron source, which produced polarized neutrons via the {sup 2}H(d-vector,n-vector){sup 3}He reaction, a deuterated liquid scintillator center detector (CD) and liquid-scintillator neutron side detectors. A coincidence between the CD and the side detectors isolated the elastic-scattering events. The CD pulse height spectrum associated with each side detector was sorted by using pulse-shape discrimination, time-of-flight techniques, and by removing accidental coincidences. A Monte Carlo computer simulation of the experiment accounted for effects due to finite geometry, multiple scattering, and CD edge effects. The resulting high-precision data (with absolute uncertainties ranging from 0.0022 to 0.0132) have a somewhat lower discrepancy with the predictions of three-body calculations, as compared to those found at lower energies.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Neutron-fragment and Neutron-neutron Correlations in Low-energy Fission

A computational method has been developed to simulate neutron emission from thermal-neutron induced fission of {sup 235}U and from spontaneous fission of {sup 252}Cf. Measured pre-emission mass-yield curves, average total kinetic energies and their variances, both as functions of mass split, are used to obtain a representation of the distribution of fragment velocities. Measured average neutron multiplicities as a function of mass split and their dependence on total kinetic energy are used. Simulations can be made to reproduce measured factorial moments of neutron-multiplicity distributions with only minor empirical adjustments to some experimental inputs. The neutron-emission spectra in the rest-frame of the fragments are highly constrained by ENDF/B-VII.1 prompt-fission neutron-spectra evaluations. The n-f correlation measurements of Vorobyev et al. (2010) are consistent with predictions where all neutrons are assumed to be evaporated isotropically from the rest frame of fully accelerated fragments. Measured n-f and n-n correlations of others are a little weaker than the predictions presented here. These weaker correlations could be used to infer a weak scission-neutron source. However, the effect of neutron scattering on the experimental results must be studied in detail before moving away from a null hypothesis that all neutrons are evaporated from the fragments.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Feeding of the 11/2{sup -} isomers in stable Ir and Au isotopes

Excited states in {sup 191}Ir, {sup 193}Ir, and {sup 197}Au were studied and absolute partial {gamma}-ray cross sections were measured using the (n,n{sup '}{gamma}) reaction. A Compton-suppressed germanium-detector array (GEANIE) for {gamma}-ray spectroscopy was used for the measurement and the broad-spectrum pulsed neutron source of the Los Alamos Neutron Science Center's WNR facility provided energetic neutrons. The energy of the incident neutrons was determined using the time-of-flight technique. Absolute partial {gamma}-ray cross sections were measured up to incident neutron energy of 20 MeV for several transitions feeding directly the 11/2{sup -} isomers and ground states in {sup 191}Ir, {sup 193}Ir, and {sup 197}Au. The feeding of the 11/2{sup -} isomers, which originate from the odd proton occupying the h{sub 11/2} orbital, was found for the three targets to be very similar and increasing relative to the feeding of the corresponding ground state with increasing neutron energy up to E{sub n}{approx}10 MeV. Above this neutron energy the opening of the (n,2n) reaction channel strongly affects the population of the isomers and leads to a decrease of their relative population compared to the population of the ground states. The experimental results are compared with theoretical predictions from the GNASH reaction model calculation implementing a version of the spin distribution for the pre-equilibrium reaction piece with either a compound nucleus spin distribution (CN-GNASH) or a Feshbach-Kerman-Koonin (FKK-GNASH) quantum mechanical spin distribution. The effects of the spin cutoff parameter values on the population of states are examined. Evidence is presented that FKK-GNASH provides a description of the experimental data that mitigates the need for adjustment of the level density parameter to fit the data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Development of Design for the STS Extraction Magnet System

The Oak Ridge National Laboratory STS Project will enhance the Spallation Neutron Source by adding a new neutron source. The upgrade includes a 30% increase in beam energy and a 50% boost in beam current, doubling the accelerator's power capability to 2.8 MW. The Ring-to-Second-Target Beam Transport (RTST) system is vital in directing high-energy proton beams to the new second target station. New magnets have to fit into a restricted space within the existing beamline to add the new extraction line. New, fast kicker magnets (Pulsed Dipole), a focusing quad with an aperture for both beamlines (Large Quad) and the replacement of existing 21Q40 Quads with 'Narrow Quads' having identical fields as the existing design are Fermilab's responsibility. The design of these magnets poses unique challenges, as in addition to the high requirements on the quality of magnetic fields, they are subject to major restrictions related to their dimensions.

Chernenok, V. [Fermilab] (ORCID:0009000778148215)↗

Comparison of secondary neutron dose in proton therapy resulting from the use of a tungsten alloy MLC or a brass collimator system

Purpose: To apply the dual ionization chamber method for mixed radiation fields to an accurate comparison of the secondary neutron dose arising from the use of a tungsten alloy multileaf collimator (MLC) as opposed to a brass collimator system for defining the shape of a therapeutic proton field. Methods: Hydrogenous and nonhydrogenous ionization chambers were constructed with large volumes to enable measurements of absorbed doses below 10{sup -4} Gy in mixed radiation fields using the dual ionization chamber method for mixed-field dosimetry. Neutron dose measurements were made with a nominal 230 MeV proton beam incident on a closed tungsten alloy MLC and a solid brass block. The chambers were cross-calibrated against a {sup 60}Co-calibrated Farmer chamber in water using a 6 MV x-ray beam and Monte Carlo simulations were performed to account for variations in ionization chamber response due to differences in secondary neutron energy spectra. Results: The neutron and combined proton plus {gamma}-ray absorbed doses are shown to be nearly equivalent downstream from either a closed tungsten alloy MLC or a solid brass block. At 10 cm downstream from the distal edge of the collimating material the neutron dose from the closed MLC was (5.3 {+-} 0.4) x 10{sup -5} Gy/Gy. The neutron dose with brass was (6.4 {+-} 0.7) x 10{sup -5} Gy/Gy. Further from the secondary neutron source, at 50 cm, the neutron doses remain close for both the MLC and brass block at (6.9 {+-} 0.6) x 10{sup -6} Gy/Gy and (6.3 {+-} 0.7) x 10{sup -6} Gy/Gy, respectively. Conclusions: The dual ionization chamber method is suitable for measuring secondary neutron doses resulting from proton irradiation. The results of measurements downstream from a closed tungsten alloy MLC and a brass block indicate that, even in an overly pessimistic worst-case scenario, secondary neutron production in a tungsten alloy MLC leads to absorbed doses that are nearly equivalent to those seen from brass collimators. Therefore, the choice of tungsten alloy in constructing the leaves of a proton MLC is appropriate, and does not lead to a substantial increase in the secondary neutron dose to the patient compared to that generated in a brass collimator.

61 RADIATION PROTECTION AND DOSIMETRY↗