Search NASA⌕ Search

SEARCH · Search NASA

Results for “Operating Mode”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Grid Forming Inverter With Increased Short-Circuit Contribution to Address Inverter-Based Microgrid Protection Challenges

Substantial differences in fault levels between grid-tied and islanded modes is one of the primary challenges of microgrid protection. During grid-tied mode, the bulk grid provides significant short-circuit, while during islanded operation the short-circuit magnitude is small due to inverter-based resources limiting their current output close to nominal ratings. Consequently, conventional distribution protection strategies based on overcurrent cannot reliably protect microgrids when operating in islanded mode. Fuses and circuit breakers are particularly affected because of their inverse characteristics. Presently, the absence of affordable solutions for protecting microgrids in islanded mode leads to microgrids shutting down during electrical faults. The contribution of this article is two-fold. The first innovation proposes specific hardware modifications to grid-forming inverters to increase their short-circuit current during electrical faults. The second innovation introduces a novel control strategy designed to preserve control stability margins even when the grid-filter saturates, ensuring sinusoidal output currents under normal and fault conditions. Through experimental results, the inverter with the proposed modifications can provide more than three-times its nominal current during electrical faults. For the prototype testbed, this was sufficient to enable the use of traditional legacy overcurrent protection, achieving the fuse-to-relay and relay-to-relay minimum coordination time for the line-to-ground, line-to-line to ground, and three-phase electrical faults.

42 ENGINEERING↗

High Dynamic Voltage Range Studies of Piezoelectric Multilayer Actuators at Low Temperatures

Piezo actuators are used for resonance control in superconducting linacs. In high accelerating gradients linacs, such as those operated in a pulsed mode, the piezos require a large operating voltage. This is due to the Lorentz forced detuning which causes a large frequency shift and is compensated with an active piezo-tuning system. In this high dynamic voltage range the piezo is expected to warm up drastically due to it being in an insulated vacuum. This study characterizes the dielectric properties (capacitance, dielectric losses), the piezo stroke (from geophone), and thermal properties such as heating. Results obtained in the temperature range of 20K to 300K will be presented and discussed.

43 PARTICLE ACCELERATORS↗

Apparatus and method for fusion of compute and switching functions of exascale system into a single component by using configurable network-on-chip fabric with distributed dual mode input-output ports and programmable network interfaces

Described is an apparatus which comprises: a Network-On-Chip fabric using crossbar switches, having distributed ingress and egress ports; and a dual-mode network interface coupled to at least one crossbar switch, the dual-mode network interface is to include: a dual-mode circuitry; a controller operable to: configure the dual-mode circuitry to transmit and receive differential signals via the egress and ingress ports, respectively, and configure the dual-mode circuitry to transmit and receive signal-ended signals via the egress and ingress ports, respectively.

97 MATHEMATICS AND COMPUTING↗

Energy recovery in capacitive deionization systems with inverted operation characteristics

Capacitive deionization (CDI) operated under inverted mode involves electronic charging and discharge steps with corresponding ion concentration and desalting coupled with simultaneous energy storage. In this work, an energy recovery system derived from a Cuk dc–dc converter is explored to transfer the energy stored from one inverted capacitive deionization (i-CDI) cell during the electronic discharge step to another during the charge step, decreasing the overall energy requirement for capacitive water desalination. The i-CDI cell, a subset of CDI architecture operated in an inverted mode, is improved by incorporating ion-selective membranes to allow inverted membrane capacitive deionization (i-MCDI), leading to enhanced charge storage achieved with reduced energy input. For example, in comparison to i-CDI that requires ~12 J g -1 of energy input, the i-MCDI cell requires only 8 J g -1 . By incorporating the recovery system, the energy penalty can be reduced to only require ~8 and 4 J g -1 for i-CDI and i-MCDI cells, respectively. Improvement in energy recovery was shown to be achieved by reducing charge leakage, with the i-MCDI cell showing up to 3 times the leakage resistance of the i-CDI cell.

54 ENVIRONMENTAL SCIENCES↗

JGI-Trichoderma v1.0

There is a series of Python and bash scripts to parse genomics datasets used to evaluate the coevolution of gene families and the feature importance of gene families using an SVM classifier. - Cover analysis: takes a list of single-copy genes in a set of genomes, aligns and builds the gene trees to determine if two gene families have a signature of covariation with one another. It parses the files to run phykit cover script described here: https://jlsteenwyk.com/PhyKIT/usage/index.html - SVM-classifier: This Python script is an SVM-based genomic classifier designed for biological data analysis. It combines machine learning with feature selection to identify important genomic markers and classify biological samples. Core Functionality: The script uses Support Vector Machines from scikit-learn to classify genomic data, incorporating SelectKBest for automated feature selection and leave-one-out cross-validation for performance assessment. It operates in multiple modes: feature ranking, optimal combination discovery, and sample prediction. Primary Applications: Genomic sample classification and biomarker discovery Feature importance analysis in high-dimensional biological datasets Prediction of sample categories based on genomic profiles Research applications requiring robust classification of biological data Key Advantages: High-dimensional handling: SVMs excel with genomic data's typical high feature-to-sample ratios Integrated feature selection: Reduces noise and computational overhead while identifying key markers Probability estimation: Provides confidence scores essential for biological interpretation Validation robustness: Leave-one-out cross-validation ensures reliable performance metrics Operational flexibility: Multiple analysis modes support different research phases from exploration to prediction

Stecca Steindorff, Andrei [Lawrence Berkeley Natio↗

Compact Multicell Superconducting Crab Cavity for ILC

We propose a novel design of a crab cavity (CC) for the ILC project with low parasitic High Order Modes (HOM) losses and preserving the beam emittance, which is critical for operation with high beam current intensity. Multiple electrodes immersed in the hollow waveguide form a trapped-mode resonator. The transverse components of the electromagnetic field of the trapped dipole mode induce a transverse kick and efficiently deflect charged particles passing through the cavity. We present a scalable design of a superconducting Quasi-waveguide Multicell Resonator (QMiR) seamlessly connected with a beam vacuum chamber. The cavity is completely open at both ends, which significantly reduces the maximum loaded quality factor of the higher order modes (HOM), avoids complex HOM couplers, and thus simplifies the mechanical design of the cavity. The same port is used to feed RF power to the operating mode and to extract the same order modes (SOM). Finally, we estimate the expected cryogenic losses, HOM impedance limits, RF input power required, and frequency tuning for a QMiR cavity designed to operate at 2.6 GHz.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A Robust Yule-Walker Method for Online Monitoring of Power System Electromechanical Modes of Oscillation

Reliable power system operation requires that system operators maintain a satisfactory small-signal stability margin at all times. Mode meters allow system operators to continuously monitor the stability margin by analyzing synchrophasor measurements. Experience with mode meters at the Bonneville Power Administration (BPA) has revealed that mode meters sometimes suffer severe bias following transient disturbances. In this paper, a robust version of the Yule-Walker mode meter algorithm is proposed to mitigate this bias. The robust capability is introduced by modifying the estimator of the autocovariance sequence (ACS) on which the algorithm depends. Tests with field-measured data demonstrate that the robust Yule-Walker (RYW) algorithm significantly outperforms its conventional counterpart and is better able to provide system operators with accurate information about the system's stability margin.

Follum, James D.↗

The Microgrid Performance Reliability Model (MPRM) v. 1.50 Beta

The MPRM is a simulation code that is used to statistically quantify the performance and reliability of a microgrid operating in islanded mode. Performance can be expressed in terms of fuel efficiency, renewable penetration, and other operational characteristics of the grid. Reliability can be expressed in terms of frequency and magnitude of load loss on a tier-by-tier, bus-by-bus basis or on an

Eddy, John↗

Grassmann phase space methods for fermions. II. Field theory

In both quantum optics and cold atom physics, the behaviour of bosonic photons and atoms is often treated using phase space methods, where mode annihilation and creation operators are represented by c-number phase space variables, with the density operator equivalent to a distribution function of these variables. The anti-commutation rules for fermion annihilation, creation operators suggests the possibility of using anti-commuting Grassmann variables to represent these operators. However, in spite of the seminal work by Cahill and Glauber and a few applications, the use of Grassmann phase space methods in quantum-atom optics to treat fermionic systems is rather rare, though fermion coherent states using Grassmann variables are widely used in particle physics. This paper presents a phase space theory for fermion systems based on distribution functionals, which replace the density operator and involve Grassmann fields representing anti-commuting fermion field annihilation, creation operators. It is an extension of a previous phase space theory paper for fermions (Paper I) based on separate modes, in which the density operator is replaced by a distribution function depending on Grassmann phase space variables which represent the mode annihilation and creation operators. This further development of the theory is important for the situation when large numbers of fermions are involved, resulting in too many modes to treat separately. Here Grassmann fields, distribution functionals, functional Fokker–Planck equations and Ito stochastic field equations are involved. Typical applications to a trapped Fermi gas of interacting spin 1/2 fermionic atoms and to multi-component Fermi gases with non-zero range interactions are presented, showing that the Ito stochastic field equations are local in these cases. For the spin 1/2 case we also show how simple solutions can be obtained both for the untrapped case and for an optical lattice trapping potential.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

An experimental study of the behavior of a high efficiency residential heat pump in cooling mode with common installation faults imposed

Faults are believed to be common in split system air-conditioner and heat pump systems, due to operating degradation or installation problems. Common faults include improper refrigerant charge, reduced evaporator airflow, liquid line restrictions, and the presence of non-condensable gas. Laboratory tests were used to quantify fault impacts on performance of a heat pump system, and impacts on indicator variables such as refrigerant temperatures and pressures. This paper describes a large set of laboratory tests implemented on a high efficiency heat pump operating in cooling mode. This system uses R-410A refrigerant and has a rotary compressor, TXV, two accumulators, and a compensator. A small number of previous experimental studies have been done previously to study the effects of some operating faults, but none has examined a modern system with these components. The tests were conducted with a range of fault intensities and driving conditions. The results are compared to previous researchers’ experimental results. The system’s performance was found to be quite robust in the presence of faults. The TXV, accumulators, and compensator significantly reduce sensitivity to refrigerant charge and liquid line restriction faults, and other faults to a lesser extent.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Discrete variable valve lift engine systems and methods

A method of providing a rocker arm set for a valvetrain includes providing a first rocker arm configured as a switching rocker arm for a first intake valve, and providing a second rocker arm configured as a fixed rocker arm for a second intake valve, the second rocker arm operating in a normal Otto cycle mode. The first rocker arm operates in a late intake valve closing (LIVC) mode where the first rocker arm is configured to close the first intake valve later than the second intake valve.

McCarthy, Jr., James E.↗

Effect of lithium coating on long pulse high performance plasma discharges in EAST

Control of impurities, fuel recycling and hydrogen content by lithium evaporative coatings and real-time lithium powder injection (LPI) in EAST are studied for high performance H-mode discharges of up to ~100 s. The results show that the lithium evaporative coatings significantly reduced both the low-Z impurity carbon and high-Z impurity tungsten as well as molybdenum concentration in the plasmas, and the impurities concentration significantly reduced with the accumulated lithium coatings and maintained well afterwards. Specifically the high-Z tungsten core impurity concentration was maintained between 3 ppm–15 ppm during the 101 s H-mode discharge, which is acceptable for the long pulse operation. In addition, real-time wall conditioning via LPI successfully reduced the core high-Z metal impurities by 50% during ~35 s long pulse H-mode discharge, exhibiting strong compatibility between real-time LPI with long pulse discharges. In addition, evaporative lithium coatings demonstrated fuel recycling control, with fuel recycling obviously reducing with lithium coatings and maintaining well afterwards. Also, the lithium evaporative coatings reduced the hydrogen minority species content, represented by the density ratio H/(H + D), from ~50% down to ~5% with accumulated lithium coatings; low hydrogen fraction improved the ICRF minority heating efficiency. Finally the real-time LPI reduced the recycling coefficient R global from 0.95 to 0.82. With these wall conditionings help, the plasma density controlled well during the 101 s long pulse H-mode discharge. Furthermore, these results provide valuable references on impurities, fuel recycling and hydrogen content control for future longer pulse high performance H-mode operation (≥400 s) in EAST and future fusion devices.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

User-Oriented Modeling Tools for Advanced Hybrid and Climate-Appropriate Rooftop Air Conditioners

Hybrid unitary air conditioning systems offer a pathway to substantially reduce energy use and peak electrical demand for cooling, heating, and ventilation in commercial buildings. Hybrid air conditioners incorporate multiple subsystems that are carefully orchestrated to provide climate- and application-specific efficiency advantages. There are a multitude of hybrid system architectures, but common subsystems include: heat recovery ventilation, indirect evaporative cooling, desiccant dehumidification, variable speed fans, modulating dampers, and multi-stage or variable-speed vapor compression cooling. Categorically, hybrid systems can operate in numerous discrete modes. For example: indirect evaporative cooling may operate for periods when the subsystem provides adequate sensible cooling, then vapor compression cooling will be included when more cooling or dehumidification is necessary. Laboratory assessments, field studies, and simulations have demonstrated that hybrid unitary air conditioners could reduce energy use for cooling and ventilation by 30-90% depending on climate and application. Heretofore, it has been challenging - if not impossible - for practitioners to model hybrid air conditioners as part of building energy simulations; and the limitation has severely obstructed broader adoption of technologies in this class. In this project, we developed a new feature for EnergyPlus that enables modeling hybrid unitary air conditioning equipment for building energy simulations. This is a significant advancement for both theory and practice, and confers public benefit by enabling practitioners to evaluate this compelling efficiency technology as a part of building energy simulations. The feature is a black-box model that requires extensive performance data for each hybrid unitary product. In parallel, we also developed new features for the Technology Performance Exchange to enable manufacturers to submit performance data in a standard format that can be used with the hybrid unitary model in EnergyPlus. Additionally, through this project we expanded university educational resources, and university- manufacturing industry collaborations in the field of energy efficiency technology. Over two years, we involved 20 undergraduate students in ambitious research projects focused on modeling complex multi-mode mechanical systems, supported three mechanical engineering bachelor theses, established undergraduate apprenticeships with multiple industry partners, and involved those partners in the process of design, validation, and debugging for the new EnergyPlus feature. The EnergyPlus feature is described and discussed in an academic article, as well as in an engineering reference, and input/output reference documentation for EnergyPlus. The Technology Performance Exchange features are live and publicly accessible, our manufacturer partners are primed to submit initial product information and performance data to the exchange, and the EnergyPlus feature is scheduled for public release in Spring 2018 as a part of EnergyPlus v8.9.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Grid-forming Control of Single- and Two-Stage Solar PV Systems with Mode Transition

Legacy power systems once dominated by con-ventional synchronous machines are transitioning into systems driven by fast-acting power-electronic converters that integrate renewable resources. The majority of integrated renewables such as PV and wind bring down system inertia and can cause stability issues due to their volatile nature. The state-of-the-art grid-forming (GFM) control is proven to enhance system inertia and stability in low-inertia systems. However, most of the existing GFM inverters are applied for battery systems, which are much more expensive than PV. Motivated by this, in this paper we propose a holistic grid-forming (GFM) control strategy for PV systems without the need of energy storage. The proposed strategy is developed on the secondary level of the grid-forming control that enables the PV inverter to operate smoothly among islanded, synchronization, GFM, and limited grid-forming (LGF) modes. The practical criteria for determining the operation modes are established and implemented based on the grid operation scenarios. Here, the proposed design is successfully validated by case studies with a laboratory prototype using Siemens Software Defined Inverters.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Simultaneous mapping of nanoscale dielectric, electrochemical, and ferroelectric surface properties of van der Waals layered ferroelectric via advanced SPM

Ferroelectric surfaces involve a complex interplay between polarization and dielectric properties, internal and external surface charge screening, and ionic and electrochemical effects. There is currently no good way to simultaneously capture all the required information at appropriate length scales. To this end, we present an advanced scanning probe microscopy approach for simultaneously mapping surface potential, dielectric, and piezoelectric properties on the nanoscale. For quantitatively mapping electromechancial properties, we utilize interferometric displacement sensing piezoresponse force microscopy, which measures the effective piezoelectric coefficient free of background artifacts such as the cantilever body electrostatics. The dielectric and surface electrochemical properties are captured during G-mode electrostatic force microscopy/Kelvin probe force microscopy operated in the lift mode. We show the capabilities of this approach on the chemically phase separated composite sample consisting of a van der Waals layered ferroelectric CuInP 2 S 6 phase and a non-polar In 4/3 P 2 S 6 phase. Finally, we demonstrate domain structure evolution during thermally stimulated phase transition.

36 MATERIALS SCIENCE↗

An Open-Source Framework for the Computational Analysis and Design of Autothermal Chemical Processes

The main project object was to develop software tools for simulating non-equilibrium autothermal processes, improving the prospects for identifying and designing such systems. The project demonstrates the use of these tools to simulate autothermal pyrolysis, a process recently developed at the pilot-plant scale at Iowa State University. In such process, instead of externally heating a reactor to pro-vide the enthalpy of pyrolysis, sufficient oxygen in the form of air is introduced into the reactor to support partial oxidation of reactants and products with the exothermic energy released supporting endothermic pyrolysis reactions. A fluidized bed is used to assure good mixing of biomass and oxidant and provide an isothermal reaction environment. The amount of oxygen required depends upon the kind of biomass being pyrolyzed and parasitic heat losses from the reactor. For example, for woody biomass pyrolyzed under conditions that simulate adiabatic operation, equivalence ratios can be as low as 0.06, compared to 0.20 or higher for autothermal gasifiers. By removing the heat transfer bottleneck of conventional pyrolysis, operation in autothermal mode allowed a significant increase in reactor throughput process, approaching five times the throughput of the conventionally operated pyrolyzer. Different simulation strategies were considered and developed: a zero-dimensional chemistry model was used to verify the applicability of kinetic schemes to predict biomass fast pyrolysis in autothermal conditions. Conventional chemical reactor models such as the plug flow reactor and the partially stirred reactor were used to investigate the role of mixing in the fluidized bed pyrolyzer and to establish the impact of mixing time on the gas-phase reactions. A comprehensive multiphase computational fluid dynamics (mCFD) framework, including polydisperse granular phase modeling and detailed chemical kinetics was formulated and used to model the experimental setup for autothermal biomass fast pyrolysis at ISU. Multiphase CFD was also used to investigate the role of biomass feed positioning on the mixing of biomass in the pyrolizer. Finally, a reduced order model (ROM), suitable to be implemented in process simulators was obtained. Both the mCFD and the ROM were validated against experiments.

09 BIOMASS FUELS↗