Search NASA⌕ Search

SEARCH · Search NASA

Results for “PENETRATION DEPTH”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

A Review of Nonscaling CW FFAs for Proton and Ion Therapy Applications

Significant progress on compact, variable-energy versions of non-scaling fixed field accelerators with alternating strong-focusing gradients (nsFFA) has been made and adapted to proton and ion therapy. Not only has isochronous (CW) capability been demonstrated in a realizable design, an isochronous racetrack format has evolved which supports lengthy, synchrotron-like straight sections. Long straight insertions promote low-loss injection and extraction systems and further facilitate extracting lower-energy orbits using a bipolar bump-magnet system. To efficiently extract variable energy using this method, the accelerator complex requires separated accelerator stages, each stage with limited but therapeutically optimized energy ranges targeting specific cancer types and penetration depths. Different energy stages further support multiple treatment rooms increasing patient throughput and reducing treatment cost. The staged system proposed here also realizes cost savings in gantries by tailoring delivery to different therapeutic energies and beam requirements, promoting the requirement for only one high-energy gantry in the facility. The proposed facility consists of 3 stages, a 30 MeV injector, a 30 - 90 MeV/nucleon FFA for shallow cancers, and 90 - 250/330 MeV/nucleon stage for deep tumors, pelvis for example. The higher energy of the final stage, 330 MeV/nucleon is preferred to support Proton Computed Tomography. Isochronous FFA stages can be designed to accelerate either protons or ions with charge to mass of 1/2.

43 PARTICLE ACCELERATORS↗

Validation of Wichner Predictive Model for Chronic Oxidation by Moisture of Nuclear Graphite

This document reports the results of multi-year extensive research on chronic oxidation of nuclear graphite by traces of moisture that might be present in the helium coolant of high-temperature gas-cooled reactors (HTGRs). The research focuses on four grades of nuclear graphite that are considered potential candidates for component fabrication in advanced nuclear reactors. The four grades are (1) PCEA (medium-fine grain, extruded, manufactured by GrafTech Inc., USA); (2) NBG-17 (medium-fine grain, vibrationally molded, manufactured by SGL Carbon, Germany/France); (3) IG-110 (microfine grain, isostatically molded, manufactured by Toyo Tanso, Japan); and (4) 2114 (microfine grain, isostatically pressed, manufactured by Mersen, USA). The experimental part of this research comprised three objectives that were consistently pursued for each graphite material: (1) accelerated oxidation tests in well-controlled conditions (temperature, gas composition) and analysis of chemical kinetic models and of their parameters for each graphite grade; (2) measurements of water vapor transport rates from H 2 O/He mixtures through thin graphite slabs for estimation of the water effective diffusivity specific to each material; (3) controlled oxidation of graphite specimens in H 2 O/He mixtures and characterization of the effects of oxidation temperatures on the density profiles of oxidized layers. These three groups of experimental results were interpreted using the model developed by Wichner et al. for predicting the penetration depth of oxidants (moisture or oxygen) as a function of oxidation conditions. Basically, starting from the kinetic and transport properties of each graphite grade, the ultimate goal was predicting the stable density profile in the oxidized layer and its dependence on the oxidation temperature. The profiles obtained this way were then compared against direct observations of oxidized layers in specimens obtained in well-controlled oxidation conditions. The general agreement between predictions and observations validated the general applicability of the Wichner model. The results obtained in this project were presented at annual Department of Energy–Advanced Reactor Technologies program reviews and at specialist meetings and conferences and were published in Oak Ridge National Laboratory (ORNL) reports and in professional journals. The results published in 2018 had an immediate impact in 2019, when a group from three US universities used ORNL kinetic data as input information in a complex simulation of chronic oxidation by moisture using the same graphite grades during long-time operation in a modular high-temperature gas-cooled reactor. Their conclusion, in line with the conclusions obtained at the end of this project, was that chronic graphite oxidation by moisture during normal operation conditions of an HTGR will be limited to a thin surface layer of graphite blocks at the reactor bottom, where the highest temperatures are. That will not affect the integrity of graphite components and reactor safety, provided the impurity concentration in the helium coolant is rigorously controlled and maintained at the design specifications.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Scientific Development of Core Block and Monolith Materials (FY2020 Progress)

This report presents the status of an effort to investigate welding and joining techniques for microreactor monolith structural materials. Previously reported results have demonstrated the potential to tier weld sub-scale components using electron beam welding. Tier welding has been investigated on larger scale test articles, and results indicate that tier welding is not feasible for larger components due to the penetration depth that is required. Additional techniques to produce full length parts have been examined, including diffusion bonding and gundrilling. Evaluations of these techniques are ongoing, and have shown early success on sub-scale components. These results indicate that while issues still exist for manufacturing microreactor structures, these challenges are better understood and solutions are in development.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Ultra-high energy density relativistic plasmas from nanostructures: scaling to ultra-high intensities (Final Report)

This project investigated the ultra-high energy density (UHED) regime of matter found in the center of stars, using a compact PW-class laser. These extreme conditions are typically only obtained in the laboratory in the central hot-spot of spherically imploded capsules in inertial confinement fusion experiments driven by the world’s largest lasers. We have shown that near-solid density arrays of aligned nanostructures can be volumetrically heated to multi-keV temperatures by irradiation at relativistic intensity with ultrafast laser pulses of modest energy, opening a path for the generation of UHED plasmas with compact lasers. This new UHED plasma generation approach promises to create an environment with extreme energy densities and degrees of ionization, record conversion of optical laser light into ultrafast x-ray pulses, gigantic magnetic fields and pressures, and directed beams of high energy particles . In this project we achieved record degree of ionization in volumetric heating solid density and near-solid density plasmas. Gold plasmas which spectra is characterized by L shell transition emission from ions with charge up to the Ne-like state, Au+ 72 were generated using ultrafast laser pulses of less than 10 J of energy from a compact laser focused to an intensity of ~ 3x10 21 Wcm -2 . We also conducted measurements to determine the heat penetration depth in Ni nanowire arrays as compared to Ni foil targets by monitoring the line emission of a Co buried tracer underneath a variable amount of Ni. The measurements revealed that the nanowire plasmas are roughly six times larger in depth than the solid density target plasmas. A result of this increased plasma in nanowire arrays is a greatly increased conversion of optical laser light into > 1 KeV x-rays, a record conversion efficiency of 20 %. Critical to the realization of the proposed experiments was the generation of ultrafast laser pulses with ultra-high contrast that can deposit the energy deep into the nanowire arrays before the nanowires explode to create a continuous plasma. Supporting the proposed experiments was the recent demonstration at Colorado State University of a Petawatt-class laser that emits 30 fs pulses at high repetition rates. The experiments combined this unique laser tool with a variety of tailored nanowire arrays fabricated in house and with an extensive suite of diagnostics. The experiments were accompanied by 3-dimensional particle-in-cell simulations and detailed atomic physics simulations with transient kinetics and radiation transport. The proposed research allowed us to continue training Ph.D students and post-docs with broad experience in HEDP Science.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measurements of the Dielectric Properties of Thin High-Explosive Samples Using a Parallel Plate Test Fixture

This report presents results of a study of the dielectric properties of several high explosive materials, including Composition B, C-4, Detasheet, Semtex 1A, Semtex 1H, and Semtex 10. The capacitance and dispersion of samples up to ten mm thick were measured at 24 and 65°C using a parallel plate test fixture. In this configuration, capacitance is proportional to the real component of the complex dielectric constant (or permittivity) of the material, while the dispersion is equal to the imaginary component of the dielectric constant divided by the real component. Measurements were performed at two temperatures to determine whether these dielectric properties might be used to monitor moderate temperature changes within these materials using an external fringing field capacitor. It was found that the real dielectric constant of the high explosives generally changed by only about 1% on heating from 24 to 65°C, and that the externally measured capacitance is therefore not a reliable parameter for monitoring temperature changes in these explosives. Temperature- based changes in the dispersion were often 20% or greater, and for several materials (e.g., Composition B, Detasheet) the temperature and dispersion showed good correlation as the temperature of the explosive was cycled up and down. It is thus possible that for some high explosives the externally measured dispersion is a useful parameter for monitoring temperature changes. However, other factors may limit the usefulness of this technique, including the need to have the plates of a fringing field capacitor in direct contact with the high explosive to obtain measurements, and the limited penetration depth of the fringing field into the explosive material.

36 MATERIALS SCIENCE↗

Cooperative Research and Development Agreement between National Energy Technology Laboratory and University of Texas at Austin [Abstract]

The project is a collaboration in the area of water filtration, including for produced waters from subsurface formations. The collaboration will provide University of Texas at Austin access to the J200 LIBS measurement machine, as well as training, facilities, and experts at NETL. NETL will gain access to UTA’s proprietary membrane samples and analysis results. The goal of this project is to determine the effects of ion depth penetration as a function of exposure on the face of the membrane samples and how this exposure may affect overall filtration efficiency. This work could help bring understanding to improved water filtration for contaminated produced waters. During this project the two parties will work together to generate and analyze experimental data from the novel filter samples to develop a journal paper co-authored by both parties.

54 ENVIRONMENTAL SCIENCES↗

Spent Crystalline Silicotitanate Storage Study—Post AP-105DF Processing

A Tank-Side Cesium Removal (TSCR) system is under development by Washington River Protection Solutions to support initial production of immobilized low-activity waste (LAW) by feeding Hanford tank supernate from tank farms to the Hanford Waste Treatment and Immobilization Plant (WTP) LAW Facility. Tank waste supernate will be filtered to remove suspended solids and then Cs will be removed by processing it through crystalline silicotitanate (CST) ion exchange media manufactured by Honeywell UOP, LLC. The Cs-loaded CST columns will be stored indefinitely, with a goal of eventual CST removal and treatment. Thus, the spent CST needs to be recoverable after undetermined storage time. Previous testing with AP-105 simulant showed that rinsing the CST bed with 3 bed volumes (1.4 apparatus volumes [AVs]) of 0.1 M NaOH resulted in a dried bed that maintained flow characteristics indicative of ease of recovery. This study explored the intermediate conditions (between feed dried in place and the 1.4 AVs of 0.1 M NaOH rinse) to evaluate CST bed properties after: 1) stoppage with feed in place; 2) stoppage after draining feed; 3) stoppage after 0.7 AV of 0.1 M NaOH rinse through column; 4) stoppage after 1.5 AVs of 0.1 M NaOH rinse through column. Post processing, each column was heated at 50 °C for 19 days under pseudo-storage conditions to simulate the expected dried and stored CST bed conditions. Testing was conducted at the small scale (12-mL bed volume); actual, Cs-depleted, AP-105 tank waste was used as the feed. Post-dried CST bed physical properties (angle of repose and penetration depth) were measured to evaluate how CST moved and flowed. All process stop-conditions resulted in a solidified CST bed except for the final condition, 1.5 AVs of 0.1 M NaOH rinse. At this small scale, the three CST beds presented an issue for retrievability after the short storage period (19 days at 50 °C). The latter case confirmed the results from simulant testing. The testing was intended to provide a preliminary assessment of issues that may arise from desiccation of CST during storage with the indicated salt solutions in place. Since these were small-scale tests, the processing system did not scale to full scale conditions exactly; however, the tests did provide insight into the impact on the dried and stored CST bed after stopping processing at an earlier step (upset condition) than normal. These results indicate that if an upset condition occurs at TSCR, a dilute hydroxide rinse should be considered before the CST dries from internal heating.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Bridging microscale to macroscale mechanical property measurements and predication of performance limitation for FeCrAl alloys under extreme reactor applications

Microscale mechanical testing has greatly benefited nuclear materials studies in at least two aspects: one is its feasibility to integrate with SEM and TEM microscopes for in situ atomic scale or microscale structural characterization to reveal fundamental details, and the other is its significance in development of accelerator-based ion irradiation technique as a surrogate method to simulate neutron damage. Ion irradiation is able to reach damage creation at a level at least three orders of magnitudes higher than test reactors. However, limited ion penetration depths, which are about a few microns for MeVs heavy ions and 10s microns for MeV light ions, make microscale mechanical tests a necessity. But, there is a great challenge to bridge microscale tests to macroscale tests because a bulk specimen of irradiated nuclear materials for high dose applications cannot be obtained in laboratory.

36 MATERIALS SCIENCE↗

Bridging microscale to macroscale mechanical property measurements and predication of performance limitation for FeCrAl alloys under extreme reactor applications

Microscale mechanical testing has greatly benefited nuclear materials studies in at least two aspects: one is its feasibility to integrate with SEM and TEM microscopes for in situ atomic scale or microscale structural characterization to reveal fundamental details, and the other is its significance in development of accelerator-based ion irradiation technique as a surrogate method to simulate neutron damage. Ion irradiation is able to reach damage creation at a level at least three orders of magnitudes higher than test reactors. However, limited ion penetration depths, which are about a few microns for MeVs heavy ions and 10s microns for MeV light ions, make microscale mechanical tests a necessity. But, there is a great challenge to bridge microscale tests to macroscale tests because a bulk specimen of irradiated nuclear materials for high dose applications cannot be obtained in laboratory.

36 MATERIALS SCIENCE↗

Bridging the length scales on mechanical property evaluation (Final Report)

The development of small-scale mechanical testing in combination with microstructural investigation is of great interest to the nuclear materials community for both materials development and monitoring applications. Dramatically reducing the sample sizes to reduce radioactivity and obtaining mechanical properties of irradiated samples is truly intriguing. Moreover, such studies promise a range of benefits including cost reduction, fundamental insight in structure-property relationships, increased statistics on less sample material, and reinvestigation of prior irradiated and tested reactor samples while simultaneously enabling the generation of mechanical test data on ion beam irradiated materials with limited penetration depths. Small scale materials testing on sub-sized samples has been studied for several decades, though it has only been after the development of micro-testing based on Focused Ion Beam (FIB) sample manufacturing in that orders of magnitude smaller samples could really be investigated in a quantitative manner. In recent years, small scale mechanical testing techniques at a number of length scales has been developed for both unirradiated and irradiated (ion and neutron) materials. Technological advances made in this field have enabled ex-situ and in-situ transmission electron microscopy (TEM) and scanning electron microscopy (SEM) examination, thus leading to more accurate measurements as well as additional mechanistic information. A recent review of the benefits of these techniques show that these techniques are at a stage to tackle multi-scale ranges of materials investigations and can be utilized to obtain fundamental science-based understanding of nuclear materials. Considering the tremendous advances made, one can see how small-scale mechanical testing techniques combined with modeling can enable true small scale to bulk scale mechanical property correlations. However, for the engineering community to adapt this approach fully, one needs to demonstrate that a) that these techniques can produce results with high fidelity and reproducibility, b) generate engineering stress-strain data that one can utilize to understand bulk behavior, and c) generate new insight into relevant phenomena fostering the true understanding of radiation damage and microstructure in materials for nuclear applications. It is the objective of this proposal to bridge the length scale between macro- and micro- scale mechanical testing of unirradiated and irradiated materials. This involves the development and demonstration of procedures for multi-scale mechanical testing that enable high fidelity reproducibility of data and the generation bulk property data from small-scale mechanical tests. Through this, the proposal aims to enhance the confidence in the obtained data at the smaller length scales and enhance the insight provided from these techniques for bulk scale applications on both unirradiated and irradiated materials.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Spent Crystalline Silicotitanate Storage Study

Washington River Protection Solutions is working to support initial production of immobilized low-activity waste (LAW) by feeding Hanford tank supernate from tank farms to the Hanford Waste Treatment and Immobilization Plant (WTP) LAW Facility. This goal incorporates the design of a Tank-Side Cesium Removal (TSCR) system, which filters tank waste supernate to remove suspended solids and then removes Cs by processing it through crystalline silicotitanate (CST) ion exchange media manufactured by Honeywell UOP, LLC. The 137 Cs-depleted product is intended to be sent to the WTP for vitrification. The Cs-loaded CST columns will be stored indefinitely, with a goal of eventual CST removal and treatment. Thus, the spent CST needs to be recoverable. The testing described herein looks to potential upset process conditions where CST storage may be required before various rinse steps are completed. This study evaluated upset conditions at three sequential processing steps envisioned for TSCR (feed, 0.1 M NaOH rinse, water rinse), and in-column drying with compressed air (normal end step) to assess impacts on the nature of the CST bed. Testing was conducted at the small scale (12-mL bed volume); simulated AP-105 tank waste was used as the feed. Following process disruption, the CST bed was dried in place at 70 °C. Post-dried CST bed physical properties (angle of repose, penetration depth, particle morphological changes) were measured to evaluate how CST moved and flowed. The testing is intended to provide a preliminary assessment of issues that may arise from desiccation of CST with the indicated salt solutions in place. Since these were small-scale tests, the processing conditions will not match full scale conditions exactly; however, the tests do provide insight into the impact of stopping processing at an earlier step than normal. Except for the feed that was dried in-place, all other process stop-conditions showed the CST bed flowed well after drying. At this small scale, CST beds would not present an issue for retrievability. The feed that was dried in place had solidified into a rock-hard monolith with no movement possible. Samples had to be chipped from the surface.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Low-Cost X-Ray CT System for Imaging of Roots

The goal of this project was to develop and demonstrate an innovative, low cost, field deployable, stationary 3D x-ray computed tomography (CT) system that will image total root phenotypes with a micron size resolution at a throughput of hundreds of plants per cycle. This system is based on UHV’s unique low cost linear x-ray tube technology and sophisticated reconstruction & image segmentation algorithms developed at University of Massachusetts, Lowel and University of Nottingham; and was tested for several types of soils at University of Wisconsin and Texas A&M University. Currently, no technologies exist that have been designed to image roots in complex media such as agricultural field conditions. Due to its small size, high resolution & fast imaging of fine roots, low power consumption, large penetration depth (i.e. ability to see through several feet of soil) and ease of field deployability, this CT system will increase the speed and efficacy of discovery, field translation, and deployment of improved crops and systems that improve soil carbon accumulation and storage, decrease N2O emissions, and improve water efficiency leading towards advancements that could mitigate 10% of the total US Greenhouse gases. This degree of imaging in the field has never been available and would be invaluable to scientists in understanding how environmental conditions and phenotypic variations contribute to carbon deposition through root development.

54 ENVIRONMENTAL SCIENCES↗

MULTI-TECHNIQUE CHARACTERIZATION OF SUPERCONDUCTING MATERIALS FOR PARTICLE ACCELERATOR APPLICATIONS

We investigated the performance limitations of superconducting radio-frequency (SRF) cavities and materials using multiple experimental techniques. In particular, this study focuses on understanding the surface properties of nitrogen-doped Nb cavities and super?conducting thin films with higher Tc such as Nb3Sn. The main goal of this work is to use different techniques to better understand each aspect of the complex loss mechanism in superconductors to further improve the already highly efficient SRF cavities. Nitrogen doping applied to a Nb SRF cavity significantly improves the quality factor Q0 compared to a conventional Nb cavity, at an expense of reduced maximum accelerating gradient. The early quench mechanism was analyzed by using temperature maps before and during the quenching. The temperature maps revealed insignificant heating before the quench, and we concluded that nitrogen doping reduces critical magnetic fields in local regions, leading to premature quenching. To understand the origin of the increasing Q0 with the rf field, the density of states (DOS) of cold spots from nitrogen-doped and standard cavities were measured and analyzed using scanning tunneling microscopy. The results suggested that nitrogen doping reduces the spatial inhomogeneity of superconducting properties and shrinks the metallic suboxide layers, which tunes the DOS in such a way as to produce the field-induced reduction in the surface resistance. To characterize SRF thin films, an experimental setup for measuring a coplanar waveguide (CPW) resonator was developed and tested. A surface impedance measurement of the Nb film showed good agreement with the BCS calculation. The preliminary results from measurements of Nb3Sn and NbTiN films are also presented here. The nonlinear Meissner effect was investigated in Nb3Sn film CPW resonators by mea?suring the resonant frequency as a function of a parallel magnetic field. Contrary to a conventional quadratic dependence of the penetration depth ?(B) on the applied magnetic field B, as expected in s-wave superconductors, nearly a linear increase of ?(B) with B was observed. It was concluded that this behavior of ?(B) is due to weakly linked grain bound?aries on the polycrystalline Nb3Sn films, which can mimic the NLME expected in a clean d-wave superconductor.

Makita, Junki↗

Photoinhibition of comammox reaction in Nitrospira inopinata in a dose- and wavelength-dependent manner

Apparent contribution of complete ammonia-oxidizing organisms (comammox) to the global nitrogen cycle highlights the necessity for understanding niche differentiation of comammox bacteria among other ammonia oxidizers. While the high affinity for ammonia of the comammox species Nitrospira inopinata suggests their niche partitioning is expected to be centered in oligotrophic environments, their absence in nutrient-depleted environments (such as the oceans) suggests that other (abiotic) factors might control their distribution and spatial localization within microbial communities. Many ammonia- and nitrite-oxidizing organisms are sensitive to light; however, the photosensitivity of comammox has not been explored. Since comammox bacteria encode enzymatic machinery homologous to canonical ammonia-and nitrite-oxidizers, we hypothesized that comammox N. inopinata, the only available pure culture of this group of microorganisms, may be inhibited by illumination in a similar manner. We evaluated the impact of light intensity, wavelength, and duration on the degree of photoinhibition for cultures of the comammox species N. inopinata and the soil ammonia-oxidizing archaea Nitrososphaera viennensis. Both species were highly sensitive to light. Interestingly, mimicking diurnal light exposure caused an uncoupling of ammonia and nitrite oxidation in N. inopinata, indicating nitrite oxidation might be more sensitive to light exposure than ammonia oxidation. It is likely that light influences comammox spatial distribution in natural environments such as surface fresh waters according to diurnal cycles, light attenuation coefficients, and the light penetration depths. Our findings therefore provide ecophysiological insights for further studies on comammox both in field and laboratory settings.

59 BASIC BIOLOGICAL SCIENCES↗

Nondestructive Ultrasonic Inspection of Composite Materials: A Comparative Advantage of Phased Array Ultrasonic

Carbon- and glass fiber-reinforced polymer (CFRP and GFRP) composite materials have been used in many industries such as aerospace and automobile because of their outstanding strength-to-weight ratio and corrosion resistance. The quality of these materials is important for safe operation. Nondestructive testing (NDT) techniques are an effective way to inspect these composites. While ultrasonic NDT has previously been used for inspection of composites, conventional ultrasonic NDT, using single element transducers, has limitations such as high attenuation and low signal-to-noise ratio (SNR). Using phased array ultrasonic testing (PAUT) techniques, signals can be generated at desired distances and angles. These capabilities provide promising results for composites where the anisotropic structure makes signal evaluation challenging. Defect detection in composites based on bulk and guided waves are studied. The capability of the PAUT and its sensitivity to flaws were evaluated by comparing the signal characteristics to the conventional method. The results show that flaw sizes as small as 0.8 mm with penetration depth up to 25 mm can be detected using PAUT, and the result signals have better characteristics than the conventional ultrasonic technique. In addition, it has been shown that guided wave generated by PAUT also has outstanding capability of flaw detection in composite materials.

36 MATERIALS SCIENCE↗

Post-Closure Performance Assessment for Deep Borehole Disposal of Cs/Sr Capsules

Post-closure performance assessment (PA) calculations suggest that deep borehole disposal of cesium (Cs)/strontium (Sr) capsules, a U.S. Department of Energy (DOE) waste form (WF), is safe, resulting in no releases to the biosphere over 10,000,000 years when the waste is placed in a 3–5 km deep waste disposal zone. The same is true when a hypothetical breach of a stuck waste package (WP) is assumed to occur at much shallower depths penetrated by through-going fractures. Cs and Sr retardation in the host rock is a key control over movement. Calculated borehole performance would be even stronger if credit was taken for the presence of the WP.

58 GEOSCIENCES↗

Quantification of Sub-Pixel Dynamics in High-Speed Neutron Imaging

The high penetration depth of neutrons through many metals and other common materials makes neutron imaging an attractive method for non-destructively probing the internal structure and dynamics of objects or systems that may not be accessible by conventional means, such as X-ray or optical imaging. While neutron imaging has been demonstrated to achieve a spatial resolution below 10 μm and temporal resolution below 10 μs, the relatively low flux of neutron sources and the limitations of existing neutron detectors have, until now, dictated that these cannot be achieved simultaneously, which substantially restricts the applicability of neutron imaging to many fields of research that could otherwise benefit from its unique capabilities. In this work, we present an attenuation modeling approach to the quantification of sub-pixel dynamics in cyclic ensemble neutron image sequences of an automotive gasoline direct injector at a 5 μs time scale with a spatial noise floor in the order of 5 μm.

47 OTHER INSTRUMENTATION↗