High Altitude Re-entry Plasma Emulation Experiment (HARPEE)

A table-top apparatus has recently been constructed at the NASA Glenn Research Center to investigate potential solutions for the radio-frequency communication blackout problem -- experienced by landing modules during high-speed atmospheric entry. This customized plasma chamber was designed to emulate Earth-based atmospheric entry plasmas with electron densities in the range of 10^16 m^-3 to 10^19 m^-3. The system makes use of a 40-kHz, perforated coaxial electrode pair to generate a disk-shaped, static plasma with an approximate diameter and thickness of 405 mm and 100 mm, respectively. A translatable Langmuir probe was employed to characterize the radial profile of electron temperature and density as a function the 40-kHz power (< 1 kW) and dry-nitrogen flow rate (< 160 SCCM).

plasma↗

Comparison of electrical and optical characteristics in gas-phase and gas-liquid phase discharges

This paper presents an AC-excited argon discharge generated using a gas-liquid (two-phase) hybrid plasma reactor, which mainly consists of a powered needle electrode enclosed in a conical quartz tube and grounded deionized water electrode. The discharges in the gas-phase, as well as in the two-phase, exhibit two discharge modes, i.e., the low current glow-like diffuse mode and the high current streamer-like constrict mode, with a mode transition, which exhibits a negative resistance of the discharges. The optical emission spectral analysis shows that the stronger diffusion of the water vapor into the discharge region in the two-phase discharges boosts up the generation of OH (A–X) radicals, and consequently, leads to a higher rotational temperature in the water-phase plasma plume than that of the gas-phase discharges. Both the increase of the power input and the decrease of the argon flow rate result in the increase of the rotational temperature in the plasma plume of the water-phase discharge. The stable two-phase discharges with a long plasma plume in the water-phase under a low power input and gas flow rate may show a promising prospect for the degradation of organic pollutants, e.g., printing and dyeing wastewater, in the field of environmental protection.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Spectrally filtered ps–ns emission dynamics of atmospheric-pressure nanosecond pulsed plasmas

The temporal dynamics of atmospheric-pressure nanosecond pulsed plasma discharges in a pin-to-pin electrode configuration are studied using streak-camera line imaging of the interelectrode gap with a time resolution as short as ~25 ps. Discharge emission initiates homogeneously throughout the interelectrode gap with no detectable streamer propagation and then temporally decays in two distinct phases. Plasma emission bands attributed to various electronic transitions are tracked for single discharges in air and N 2 . Spectral filtering of the excited molecular states reveals that the N 2 (C–B) and N 2 (B–A) emission bands evolve in distinct early and late phases, respectively, with a time separation of ~15–20 ns. Furthermore, significant differences in the temporal dynamics of plasma discharges in air and N2 are observed. High levels of excited-state atomic oxygen and NO appear after the initial decay of the N 2 (C) state and coincide primarily with the latter phases of plasma evolution in air environments. From temporal traces of discharge emission, the formation and relaxation timescales of the electronically excited states of N 2 are quantified in pure N2 and air environments with sub-nanosecond resolution. The streak-OES (optical emission spectroscopy) technique enables quantitative time-resolved studies of key chemical species for model validation in ultra-short-pulsed plasmas.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Electron plasma dynamics during autoresonant excitation of the diocotron mode

Chirped-frequency autoresonant excitation of the diocotron mode is used to move electron plasmas confined in a Penning-Malmberg trap across the magnetic field for advanced plasma and antimatter applications. Plasmas of 10{sup 8} electrons, with radii small compared to that of the confining electrodes, can be moved from the magnetic axis to ≥90% of the electrode radius with near unit efficiency and reliable angular positioning. Translations of ≥70% of the wall radius are possible for a wider range of plasma parameters. Details of this process, including phase and displacement oscillations in the plasma response and plasma expansion, are discussed, as well as possible extensions of the technique.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Symmetry breaking in high frequency, symmetric capacitively coupled plasmas

Two radially propagating surface wave modes, “symmetric,” in which the upper and lower axial sheath fields ( E z ) are aligned, and “anti-symmetric,” in which they are opposed, can exist in capacitively coupled plasma (CCP) discharges. For a symmetric (equal electrode areas) CCP driven symmetrically, we expected to observe only the symmetric mode. Instead, we find that when the applied rf frequency f is above or near an anti-symmetric spatial resonance, both modes can exist in combination and lead to unexpected non-symmetric equilibria. We use a fast 2D axisymmetric fluid-analytical code to study a symmetric CCP reactor at low pressure (7.5 mTorr argon) and low density (~3 × 10 15 m -3 ) in the frequency range of f = 55 to 100 MHz which encompasses the first anti-symmetric spatial resonance frequency f a but is far below the first symmetric spatial resonance f s . For lower frequencies such that f is well below f a> , the symmetric CCP is in a stable symmetric equilibrium, as expected, but at higher frequencies such that f is near or greater than f a , a non-symmetric equilibrium appears which may be stable or unstable. In our study, we develop a nonlinear lumped circuit model of the symmetric CCP to better understand these unexpected results, indicating that the proximity to the anti-symmetric spatial resonance allows self-exciting of the anti-symmetric mode even in a symmetric system. The circuit model results agree well with the fluid simulations. A linear stability analysis of the symmetric equilibrium describes a transition with increasing frequency from stable to unstable.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Experimental test of whether electrostatically charged micro-organisms and their spores contribute to the onset of arcs across vacuum gaps

Recently it was proposed [L. R. Grisham et al. Phys. Plasmas 19, 023107 (2012)] that one of the initiators of vacuum voltage breakdown between conducting electrodes might be micro-organisms and their spores, previously deposited during exposure to air, which then become electrostatically charged when an electric potential is applied across the vacuum gap. This note describes a simple experiment to compare the number of voltage-conditioning pulses required to reach the nominal maximum operating voltage across a gap between two metallic conductors in a vacuum, comparing cases in which biological cleaning was done just prior to pump-down with cases where this was not done, with each case preceded by exposure to ambient air for three days. Based upon these results, it does not appear that air-deposited microbes and their spores constitute a major pathway for arc initiation, at least for exposure periods of a few days, and for vacuum gaps of a few millimeters, in the regime where voltage holding is usually observed to vary linearly with gap distance.

60 APPLIED LIFE SCIENCES↗

Plasma arc welding torch having means for vortexing plasma gas exiting the welding torch

A plasma arc welding torch is described wherein a plasma gas is directed through the body of the welding torch and out of the body across the tip of the welding electrode disposed at the forward end of the body. The plasma gas is provided with a vortexing motion prior to exiting the body by a vortex motion imparting member which is mounted in an orifice housing member and carried in the forward portion of the torch body. The orifice housing member is provided with an orifice of an predetermined diameter through which the electric arc and the plasma gas exits.

Rybicki, Daniel J.↗

Experimental Verification of the Kruskal-Shafranov Stability Limit in Line-Tied Partial Toroidal Plasmas

The stability properties of partial toroidal flux ropes are studied in detail in the laboratory, motivated by ubiquitous arched magnetic structures found on the solar surface. The flux ropes studied here are magnetized arc discharges formed between two electrodes in the Magnetic Reconnection Experiment (MRX) [Yamada et al., Phys. Plasmas, 4, 1936 (1997)]. The three dimensional evolution of these flux ropes is monitored by a fast visible light framing camera, while their magnetic structure is measured by a variety of internal magnetic probes. The flux ropes are consistently observed to undergo large-scale oscillations as a result of an external kink instability. Using detailed scans of the plasma current, the guide field strength, and the length of the flux rope, we show that the threshold for kink stability is governed by the Kruskal-Shafranov limit for a flux rope that is held fixed at both ends (i.e., qa = 1).

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Influence of the electrode system on the emission characteristics of a vacuum spark

The influence of the electrode system on the emission characteristics of a high-current low-inductance vacuum spark is investigated. It is shown that the structure and composition of the spark plasma radiating in the X-ray spectral range depend substantially on the geometry and relative position of the electrodes. A mechanism related to the effect of the initial distribution of the electric field in the electrode gap is proposed to explain such a dependence. The conditions in which the radiating plasma forms from the erosion products of one or both electrodes are determined.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Dynamics of the spatial structure of pulsed discharges in dense gases in point cathode−plane anode gaps and their erosion effect on the plane electrode surface

The dynamics of the spatial structure of the plasma of pulsed discharges in air and nitrogen in a nonuniform electric field and their erosion effect on the plane anode surface were studied experimentally. It is established that, at a nanosecond front of the voltage pulse, a diffuse discharge forms in the point cathode–plane anode gap due to the ionization wave propagating from the cathode. As the gap length decreases, the diffuse discharge transforms into a spark. A bright spot on the anode appears during the diffuse discharge, while the spark channel forms in the later discharge stage. The microstructure of autographs of anode spots and spark channels in discharges with durations of several nanoseconds is revealed. The autographs consist of up to 100 and more microcraters 5–100 μm in diameter. It is shown that, due to the short duration of the voltage pulse, a diffuse discharge can be implemented, several pulses of which do not produce appreciable erosion on the plane anode or the soot coating deposited on it.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Dynamics of X-pinches Powered by a Capacitor Bank

X-pinches are formed by crossing two metal wires in the shape of the letter ‘X’ between the electrodes of a pulsed power device. The plasma generated then evolves in complex ways and has been the subject of many experiments and simulations, both as a plasma object and for its use as a source of intense soft x-rays, of interest to high energy density plasma (HEDP) studies. The dynamics of the x-pinch that lead to the emission x-ray photons begin soon after this initial explosive phase, resulting in the formation of a micro z-pinch (≤ 300 µm long, ~100 µm diameter) at the crossing point. If the current is high enough, then a subsonic plasma implosion in the micro z-pinch begins, which creates a high density, high temperature plasma. These x-pinches have been typically studied at the nanosecond time scale (rise-time $τ_r ≤ 100 ns, dI/dt > 1 kA/ns$). The microsecond x-pinch ($I_p~350 kA, τ_{1/4} = 1 µs, 0.3 kA/ns$) allows a different parameter space to be studied that compliments HEDP studies in the nanosecond regime (with an attendant lower hard-radiation hazard) but it also creates plasma conditions that are interesting in their own right, with features that make it a good model for studying the hydrodynamics of astrophysical jets, for example. With high electron density and temperatures pushing close to 0.5 keV, it is relevant for high energy density studies and provides a suitable test bed for the spectroscopy of highly ionized atoms. The aim of the original proposal was to initiate a new experimental plasma research program at Florida A&M University with three main objectives: (1) To create x-pinch plasmas from different materials using a direct capacitor bank discharge and to study the dynamics of the high-density plasmas and their associated soft x-ray emission properties and potential applications. (2) Understanding the nature of the supersonic plasma jets observed in the mid-plane of the microsecond x-pinch and their relevance as a laboratory model for studying astrophysical jets. (3) To provide a research platform to support the education of under-represented undergraduate and graduate students at Florida A&M University and to provide training in high energy density laboratory plasma physics. Each of the main objectives has been met and results of the work have been published in refereed journals or presented at several scientific meetings. A number of students both undergraduate and graduate have participated in the research program in a hands-on way and have thereby acquired training in high energy density physics. The success of the work can also be measured in two PhD dissertations (one of which is still in progress). The acquisition of important research equipment and instrumentation means that the work can continue in some fashion.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development and initial operating characteristics of the 20 megawatt linear plasma accelerator facility

A 20-megawatt linear plasma accelerator facility, a steady flow, Faraday-type plasma accelerator facility for high velocity aerodynamic testing, was constructed, developed, and brought to an operational status. The accelerator has a 63.5-mm-square and 0.5-meter-long channel and utilizes nitrogen-seeded with 2 % mole fraction of cesium vapor. Modification of the original accelerator design characteristics and the improvements necessary to make the arc heater a suitable plasma source are described. The measured accelerator electrode current distribution and the electrode-wall potential distributions are given. The computed and the measured values are in good agreement. Measured pitot pressure indicates that an accelerator exit velocity of 9.2 km/sec, is obtained with 30 of the 36 electrode pairs powered and corresponds to a velocity increase to about 2 1/4 times the computed entrance velocity. The computed stagnation enthalpy at the accelerator exit is 92 MJ/kg, and the mass density corresponds to an altitude of about 58 km. The 92 MJ/kg stagnation enthalpy corresponds to a kinetic energy content at low temperature equivalent to a velocity of 13.6 km/sec.

Carter, A. F.↗

Ultraviolet laser excitation source

A new intense ultraviolet light source has been developed from an array of hypocycloidal pinch (HCP) devices. The basic unit of the array is constructed with three disk electrodes and is capable of producing dense plasmas at temperatures up to 10,000,000 K. Very high input power levels to the array are possible without significantly shortening its useful life, in strong contrast with conventional xenon flashlamps. The new light source, when operated with Ar and Xe gas mixtures at high pressures (approximately 5 x 10 to the 4th Pa), produced a light output of over 100 MW in the near-UV spectral range and successfully pumped an iodine photodissociation laser at 1.315 microns. A xenon recombination laser at 2.027 microns was also pumped in the HCP array.

Lee, J. H.↗

Laser-Induced Fluorescence Helps Diagnose Plasma Processes

Technique developed to provide in situ monitoring of rates of ion sputter erosion of accelerator electrodes in ion thrusters also used for ground-based applications to monitor, calibrate, and otherwise diagnose plasma processes in fabrication of electronic and optical devices. Involves use of laser-induced-fluorescence measurements, which provide information on rates of ion etching, inferred rates of sputter deposition, and concentrations of contaminants.

Beattie, J. R.↗

The influence of the secondary electron induced asymmetry on the electrical asymmetry effect in capacitively coupled plasmas

In geometrically symmetric capacitive radio-frequency plasmas driven by two consecutive harmonics, a dc self-bias can be generated as a function of the phase shift between the driving frequencies via the Electrical Asymmetry Effect (EAE). Recently, the Secondary Electron Asymmetry Effect (SEAE) was discovered (Lafleur et al., J. Phys. D: Appl. Phys. 46, 135201 (2013)): unequal secondary electron emission coefficients at both electrodes were found to induce an asymmetry in single-frequency capacitive plasmas. Here, we investigate the simultaneous presence of both effects, i.e., a dual-frequency plasma driven by two consecutive harmonics with different electrode materials. We find that the superposition of the EAE and the SEAE is generally non-linear, i.e., the asymmetries generated by each individual effect do not simply add up at all phases. The control ranges of the dc self-bias and the mean ion energy can be enlarged, if both effects are combined.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Electric field induced needle-pulsed arc discharge carbon nanotube production apparatus: Circuitry and mechanical design

A simple and low cost apparatus is reported to produce multiwall carbon nanotubes and carbon nano-onions by a low power short pulsed arc discharge reactor. The electric circuitry and the mechanical design details and a micro-filtering assembly are described. The pulsed-plasma is generated and applied between two graphite electrodes. The pulse width is 0.3 {mu}s. A strong dc electric field is established along side the electrodes. The repetitive discharges occur in less than 1 mm distance between a sharp tip graphite rod as anode, and a tubular graphite as cathode. A hydrocarbon vapor, as carbon source, is introduced through the graphite nozzle in the cathode assembly. The pressure of the chamber is controlled by a vacuum pump. A magnetic field, perpendicular to the plasma path, is provided. The results show that the synergetic use of a pulsed-current and a dc power supply enables us to synthesize carbon nanoparticles with short pulsed plasma. The simplicity and inexpensiveness of this plan is noticeable. Pulsed nature of plasma provides some extra degrees of freedom that make the production more controllable. Effects of some design parameters such as electric field, pulse frequency, and cathode shape are discussed. The products are examined using scanning probe microscopy techniques.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effect of axial magnetic field on a 2.45 GHz permanent magnet ECR ion source

Herein, we conduct a fundamental study to improve the generation efficiency of a multi-charged ion source using argon. A magnetic field of our electron cyclotron resonance ion source is composed of a permanent magnet and a solenoid coil. Thereby, the axial magnetic field in the chamber can be tuned. Using the solenoid coil, we varied the magnetic field strength in the plasma chamber and measured the ion beam current extracted at the electrode. We observed an approximately three times increase in the Ar{sup 4+} ion beam current when the magnetic field on the extractor-electrode side of the chamber was weakened. From our results, we can confirm that the multi-charged ion beam current changes depending on magnetic field intensity in the plasma chamber.