Search NASA⌕ Search

SEARCH · Search NASA

Results for “Path integrals”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Measurement of Sauter Mean Diameter (SMD) in Diesel Sprays Using a Scattering-Absorption Measurement Ratio (SAMR) Technique

A new diagnostic for the quantification of Sauter Mean Diameter (SMD) in high-pressure fuel sprays has been recently developed using combined optical and x-ray measurements at the Georgia Institute of Technology and Argonne National Laboratory, respectively. This diagnostic utilizes liquid scattering extinction measurements from diffuse back-illumination imaging, conducted at Georgia Tech, and liquid absorption measurements from x-ray radiography, conducted at Argonne’s Advanced Photon Source. The new diagnostic, entitled the Scattering Absorption Measurement Ratio (SAMR), quantifies two-dimensional distributions of path integrated SMD, enabling construction of the spatial history of drop size development within practical fuel sprays. This technique offers unique benefits over conventional drop-sizing methods in that it can be more robust in optically dense regions of the spray, while also providing high spatial and temporal resolution of the corresponding droplet field. The methodology for quantification of SMD distributions using the SAMR technique has been previously introduced and demonstrated in diesel sprays using the Engine Combustion Network Spray D injector, however a more detailed treatment of measurement uncertainties has been needed. In the current work, we present a summary of the various sources of measurement uncertainty in the SAMR diagnostic, like those due to the experimental setup, data processing methods, and theoretical assumptions, and assess how these sources of uncertainty affect the quantified SMD. The spatially-resolved SMD measurements that result from the SAMR diagnostic will be especially valuable to the engine modeling community for the quantitative validation of spray submodels in engine CFD codes. Careful evaluation and quantification of measurement uncertainties is important to support accurate model validation and to ensure the development of more predictive spray models.

33 ADVANCED PROPULSION SYSTEMS↗

Advancing the Authenticatable Container Tracking System (ACTS)

The Authenticatable Container Tracking System (ACTS) is an extensible secure container tag that can be used to optimize chain-of-custody monitoring for packaged nuclear materials as they are being stored, processed, and transported. Based on the ultra–low power TI MSP430 mixed-signal microcontroller, ACTS is an active device that uses an almost-universal core platform that can be appropriately configured with expansion modules to provide the application-specific data acquisition, data logging, container sealing, and communications functions needed for 21st century material accountancy, monitoring, and tracking applications. This core architecture enables appropriately designed modules to be easily interfaced to the basic system, providing an integration path for current and new technologies. ACTS contains a built-in set of sensors and supports an expansion bus for up to six additional communications, tracking, authentication, encryption, sealing, location, or sensing modules that may enhance the monitoring and tracking of designated containers for specific applications. To date, testing has used an IEEE 802.15.4-2011 ultra-wideband–compliant wireless transceiver module that has additional capabilities for indoor positioning and proximity location. Proximity-based location (i.e., where an ACTS tag knows where it is relative to other ACTS tags) will be explored as a continuity-of-knowledge mechanism to determine unauthorized movement of containers in storage arrays of many items. Partners for this system are Oak Ridge National Laboratory, Argonne National Laboratory, Savannah River National Laboratory, Pacific Northwest National Laboratory, and commercialization partner the Aquila Group.

Younkin, James↗

Time Evolution in Quantum Cosmology

The quantum description of time evolution in non-linear gravitational systems such as cosmological space-times is not well understood. We show, in the simplified setting of mini-superspace, that time evolution of this system can be obtained using a gauge fixed path integral, as long as one does not integrate over proper time. Using this gauge fixed action we can construct a Hamiltonian in the coherent - or classical - state basis. We show that by construction the coherent states satisfy the classical dynamical equations of General Relativity. They do not satisfy the Hamiltonian constraint. A consequence of this is that the Wheeler-DeWitt equation should not be satisfied in quantum gravity. Classical states have a natural non-trivial time evolution since they are not eigenstates of the Hamiltonian. A general feature of the unconstrained quantum theory of gravity is the prediction of a pressureless dark matter component of either sign energy density in the classical universe which may lead to novel phenomenology.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The Classical Equations of Motion of Quantized Gauge Theories, Part I: General Relativity

In this and a companion paper, we show that quantum field theories with gauge symmetries permit a broader class of classical dynamics than typically assumed. In this article, we show that the dynamics extracted from the path integral or Hamiltonian formulation of general relativity allows for classical states that do not satisfy the full set of Einstein's equations. This amounts to loosening the Hamiltonian and momentum constraints that are imposed on the initial state. Nevertheless, the quantum theory permits gauge invariant time evolution of these states. The time evolution of these states is such that at the classical level the full set of Einstein's equations would appear to hold, with the physical effects of these states being attributable to an auxiliary, covariantly conserved energy-momentum tensor with no internal degrees of freedom. We derive the generalized Einstein equations for these states and show that a homogeneous and isotropic initial background state contributes to expansion identical to cold dark matter. The inhomogeneous components of this state could source curvature perturbations that grow linearly at linear order. This auxiliary contribution to Einstein's equations could have either sign and thus provide a trivial way to violate the null energy condition, enabling novel gravitational dynamics such as cosmic bounces and wormholes.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Signal-to-noise improvement through neural network contour deformations for 3D $SU(2)$ lattice gauge theory

Complex contour deformations of the path integral have been demonstrated to significantly improve the signal-to-noise ratio of observables in previous studies of two-dimensional gauge theories with open boundary conditions. In this work, new developments based on gauge fixing and a neural network definition of the deformation are introduced, which enable an effective application to theories in higher dimensions and with generic boundary conditions. Improvements of the signal-to-noise ratio by up to three orders of magnitude for Wilson loop measurements are shown in $SU(2)$ lattice gauge theory in three spacetime dimensions.

Detmold, William↗

Asymptotics of Selberg-like integrals by lattice path counting

We obtain explicit expressions for positive integer moments of the probability density of eigenvalues of the Jacobi and Laguerre random matrix ensembles, in the asymptotic regime of large dimension. These densities are closely related to the Selberg and Selberg-like multidimensional integrals. Our method of solution is combinatorial: it consists in the enumeration of certain classes of lattice paths associated to the solution of recurrence relations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Two-path plasmonic interferometer with integrated detector

An electrically tunable terahertz two-path plasmonic interferometer with an integrated detection element can down convert a terahertz field to a rectified DC signal. The integrated detector utilizes a resonant plasmonic homodyne mixing mechanism that measures the component of the plasma waves in-phase with an excitation field that functions as the local oscillator in the mixer. The plasmonic interferometer comprises two independently tuned electrical paths. The plasmonic interferometer enables a spectrometer-on-a-chip where the tuning of electrical path length plays an analogous role to that of physical path length in macroscopic Fourier transform interferometers.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Integrative genomics reveals paths to sex dimorphism in Salix purpurea L

Sex dimorphism and gene expression were studied in developing catkins in 159 F 2 individuals from the bioenergy crop Salix purpurea , and potential mechanisms and pathways for regulating sex development were explored. Differential expression, eQTL, bisulfite sequencing, and network analysis were used to characterize sex dimorphism, detect candidate master regulator genes, and identify pathways through which the sex determination region (SDR) may mediate sex dimorphism. Eleven genes are presented as candidates for master regulators of sex, supported by gene expression and network analyses. These include genes putatively involved in hormone signaling, epigenetic modification, and regulation of transcription. eQTL analysis revealed a suite of transcription factors and genes involved in secondary metabolism and floral development that were predicted to be under direct control of the sex determination region. Furthermore, data from bisulfite sequencing and small RNA sequencing revealed strong differences in expression between males and females that would implicate both of these processes in sex dimorphism pathways. These data indicate that the mechanism of sex determination in Salix purpurea is likely different from that observed in the related genus Populus . This further demonstrates the dynamic nature of SDRs in plants, which involves a multitude of mechanisms of sex determination and a high rate of turnover.

59 BASIC BIOLOGICAL SCIENCES↗

Extraordinary properties of functional integrals and groups of diffeomorphisms

A review of the work of the authors is presented, in which corollaries of the quasi-invariance of functional integrals on the Wiener measure with respect to the action of a group of diffeomorphisms are studied, and the behavior of functional integrals with nonlinear nonlocal change of variables of integration is investigated as well. Using these substitutions, the functional integrals over discontinuous paths can be determined. The simplest models of the (Euclidean) quantum field theory are offered, in which the presence of hidden internal symmetries or the allowance for discontinuous paths in functional integrals leads to a number of paradoxical properties contradicting the conventional view.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

BXS Re-calibration

Early in the commissioning it was noticed by Cecile Limborg that the calibration of the BXS spectrometer magnet seemed to be different from the strength of the BX01/BX02 magnets. First the BX01/BX02 currents were adjusted to 135 MeV and the beam energy was adjusted to make the horizontal orbit flat. Then BX01/BX02 magnets were switched off and BXS was adjusted to make the horizontal orbit in the spectrometer line flat, without changing the energy of the beam. The result was that about 140-141 MeV were required on the BXS magnet. This measurement was repeated several times by others with the same results. It was not clear what was causing the error: magnet strength or layout. A position error of about 19 mm of the BXS magnet could explain the difference. Because there was a significant misalignment of the vacuum chamber in the BXS line, the alignment of the whole spectrometer line was checked. The vacuum chamber was corrected, but the magnets were found to be in the proper alignment. So we were left with one (or conceivably two) magnet calibration errors. Because BXS is a wedged shaped magnet, the bend angle depends on the horizontal position of the incoming beam. As mentioned, an offset of the beam position of 19 mm would increase or decrease the bend angle roughly by the ratio of 135/141. The figure of 19 mm is special and caused a considerable confusion during the design and measurement of the BXS magnet. This is best illustrated in Figure 1 which was taken out of the BXS Traveler document. The distance between the horizontal midplanes of the poles and the apex of the beam path was chosen to be 19 mm so the beam is close to the good field region throughout its entire path. Thus it seemed possible that there was an error that resulted in the beam not being on this trajectory, or conversely, that the magnetic measurements were done on the wrong trajectory and the magnet was then mis-calibrated. Mechanical measurements of the vacuum chamber made in the tunnel indicated that the vacuum chamber was in fact in the proper position with respect to the magnet - not 19 mm off to one side - so the former possibility was discounted. Review of the Fiducial Report and an interview with Keith Caban convinced me that there was no error in the coordinate system used for magnet measurements. I went and interviewed Andrew Fischer who did the magnetic measurements of BXS. He had extensive records, including photographs of the setups and could quickly answer quite detailed questions about how the measurement was done. Before the interview, I had a suspicion there might have been a sign flip in the x coordinate which because of the wedge would result in the wrong path length and a miscalibration. Andrew was able to pin-point how this could have happened and later confirmed it by looking an measurement data from the BXG magnet done just after BXS and comparing photographs. It turned out that the sign of the horizontal stage travel that drives the measurement wire was opposite that of the x coordinate in the Traveler, and the sign difference wasn't applied to the data. The origin x = 0 was set up correctly, but the wire moved in the opposite direction to what was expected, just as if the arc had been flipped over about the origin. To quantitatively confirm that this was the cause of the observed difference in calibration I used the 'grid data', which was taken with a Hall probe on the BXS magnet originally to measure the FINT (focusing effect) term, and combined it with the Hall probe data taken on the flipped trajectory, and performed the field integral on a path that should give the same result as the design path. This is best illustrated in Figure 2. The integration path is coincident with the desired path from the pivot points (x = 0) outward. Between the pivot points the integration path is a mirror image of the design path, but because the magnet is fairly uniform, for this portion it gives the same result. Most of the calibration error resulted simply from the different path length between the design path and the measured path. The results of the integration on the equivalent path are given in Table 1. The corrected calibration has been used to generate a new polynomial for BXS which was implemented in the control system.

43 PARTICLE ACCELERATORS↗

Complete algebraic reduction of one-loop tensor Feynman integrals

We set up a new, flexible approach for the tensor reduction of one-loop Feynman integrals. The 5-point tensor integrals up to rank R=5 are expressed by 4-point tensor integrals of rank R-1, such that the appearance of the inverse 5-point Gram determinant is avoided. The 4-point tensor coefficients are represented in terms of 4-point integrals, defined in d dimensions, 4-2{epsilon}{<=}d{<=}4-2{epsilon}+2(R-1), with higher powers of the propagators. They can be further reduced to expressions which stay free of the inverse 4-point Gram determinants but contain higher-dimensional 4-point integrals with only the first power of scalar propagators, plus 3-point tensor coefficients. A direct evaluation of the higher-dimensional 4-point functions would avoid the appearance of inverse powers of the Gram determinants completely. The simplest approach, however, is to apply here dimensional recurrence relations in order to reduce them to the familiar 2- to 4-point functions in generic dimension d=4-2{epsilon}, introducing thereby coefficients with inverse 4-point Gram determinants up to power R for tensors of rank R. For small or vanishing Gram determinants--where this reduction is not applicable--we use analytic expansions in positive powers of the Gram determinants. Improving the convergence of the expansions substantially with Pade approximants we close up to the evaluation of the 4-point tensor coefficients for larger Gram determinants. Finally, some relations are discussed which may be useful for analytic simplifications of Feynman diagrams.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Convergence of Feynman integrals in Coulomb gauge QCD

At 2-loop order, Feynman integrals in the Coulomb gauge are divergent over the internal energy variables. Nevertheless, it is known how to calculate the effective action, provided that the external gluon fields are all transverse. We show that, for the two-gluon Greens function as an example, the method can be extended to include longitudinal external fields. The longitudinal Greens functions appear in the BRST identities. As an intermediate step, we use a flow gauge, which interpolates between the Feynman and Coulomb gauges.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗