Search NASA⌕ Search

SEARCH · Search NASA

Results for “Quality Control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Effect of MLC leaf position, collimator rotation angle, and gantry rotation angle errors on intensity-modulated radiotherapy plans for nasopharyngeal carcinoma

The purpose of this study was to investigate the effect of multileaf collimator (MLC) leaf position, collimator rotation angle, and accelerator gantry rotation angle errors on intensity-modulated radiotherapy plans for nasopharyngeal carcinoma. To compare dosimetric differences between the simulating plans and the clinical plans with evaluation parameters, 6 patients with nasopharyngeal carcinoma were selected for simulation of systematic and random MLC leaf position errors, collimator rotation angle errors, and accelerator gantry rotation angle errors. There was a high sensitivity to dose distribution for systematic MLC leaf position errors in response to field size. When the systematic MLC position errors were 0.5, 1, and 2 mm, respectively, the maximum values of the mean dose deviation, observed in parotid glands, were 4.63%, 8.69%, and 18.32%, respectively. The dosimetric effect was comparatively small for systematic MLC shift errors. For random MLC errors up to 2 mm and collimator and gantry rotation angle errors up to 0.5°, the dosimetric effect was negligible. We suggest that quality control be regularly conducted for MLC leaves, so as to ensure that systematic MLC leaf position errors are within 0.5 mm. Because the dosimetric effect of 0.5° collimator and gantry rotation angle errors is negligible, it can be concluded that setting a proper threshold for allowed errors of collimator and gantry rotation angle may increase treatment efficacy and reduce treatment time.

61 RADIATION PROTECTION AND DOSIMETRY↗

KNOW THE STAR, KNOW THE PLANET. II. SPECKLE INTERFEROMETRY OF EXOPLANET HOST STARS

A study of the host stars to exoplanets is important for understanding their environment. To that end, we report new speckle observations of a sample of exoplanet host primaries. The bright exoplanet host HD 8673 (= HIP 6702) is revealed to have a companion, although at this time we cannot definitively establish the companion as physical or optical. The observing lists for planet searches and for these observations have for the most part been pre-screened for known duplicity, so the detected binary fraction is lower than what would otherwise be expected. Therefore, a large number of double stars were observed contemporaneously for verification and quality control purposes, to ensure that the lack of detection of companions for exoplanet hosts was valid. In these additional observations, 10 pairs are resolved for the first time and 60 pairs are confirmed. These observations were obtained with the USNO speckle camera on the NOAO 4 m telescopes at both KPNO and CTIO from 2001 to 2010.

79 ASTRONOMY AND ASTROPHYSICS↗

Comparison of German and American fabrication standards for transportation and storage containments of high level radioactive material type B packages - 15055

As the competent authority for the evaluation of German radioactive material (RAM) transport and storage packages, BAM (the German Federal Institute for Materials Research and Testing) has evaluated various international cask manufacturers regarding compliance with the German Type B(U) licensing requirements. The US NRC has recommended paragraphs in the ASME Boiler and Pressure Vessel (B and PV) Code, Section III, Division 3, as the measure to quantify the safety requirements of the US regulations regarding fabrication of RAM transportation and storage containments. The objective of this study is to compare the fabrication criteria of the German Dangerous Goods Procedural Rules (BAM-GGR) and the German Institute for Standardization (DIN) with the US quantitative measures for fabrication of RAM package containment vessels. This comparison will cover major similarities and differences between the requirements of the German standards and the ASME Code requirements for Type B package containment fabrication QC (quality control). While the material most often used for German RAM containment applications is ductile cast iron (DCI), in the US forged austenitic stainless steel is typically used. This study focuses on fabrication QC measures required to ensure reproducible and acceptable properties for DCI containments. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Examination of a Size-Change Test for Photovoltaic Encapsulation Materials: Preprint

We examine a proposed test standard that can be used to evaluate the maximum representative change in linear dimensions of sheet encapsulation products for photovoltaic modules (resulting from their thermal processing). The proposed protocol is part of a series of material-level tests being developed within Working Group 2 of the Technical Committee 82 of the International ElectrotechnicalCommission. The characterization tests are being developed to aid module design (by identifying the essential characteristics that should be communicated on a datasheet), quality control (via internal material acceptance and process control), and failure analysis. Discovery and interlaboratory experiments were used to select particular parameters for the size-change test. The choice of a sandsubstrate and aluminum carrier is explored relative to other options. The temperature uniformity of +/- 5C for the substrate was confirmed using thermography. Considerations related to the heating device (hot-plate or oven) are explored. The time duration of 5 minutes was identified from the time-series photographic characterization of material specimens (EVA, ionomer, PVB, TPO, and TPU). Thetest procedure was revised to account for observed effects of size and edges. The interlaboratory study identified typical size-change characteristics, and also verified the absolute reproducibility of +/- 5% between laboratories.

14 SOLAR ENERGY↗

Prevention of a wrong-location misadministration through the use of an intradepartmental incident learning system

Purpose: A series of examples are presented in which potential errors in the delivery of radiation therapy were prevented through use of incident learning. These examples underscore the value of reporting near miss incidents. Methods: Using a departmental incident learning system, eight incidents were noted over a two-year period in which fields were treated 'out-of-sequence,' that is, fields from a boost phase were treated, while the patient was still in the initial phase of treatment. As a result, an error-prevention policy was instituted in which radiation treatment fields are 'hidden' within the oncology information system (OIS) when they are not in current use. In this way, fields are only available to be treated in the intended sequence and, importantly, old fields cannot be activated at the linear accelerator control console. Results: No out-of-sequence treatments have been reported in more than two years since the policy change. Furthermore, at least three near-miss incidents were detected and corrected as a result of the policy change. In the first two, the policy operated as intended to directly prevent an error in field scheduling. In the third near-miss, the policy operated 'off target' to prevent a type of error scenario that it was not directly intended to prevent. In this incident, an incorrect digitally reconstructed radiograph (DRR) was scheduled in the OIS for a patient receiving lung cancer treatment. The incorrect DRR had an isocenter which was misplaced by approximately two centimeters. The error was a result of a field from an old plan being scheduled instead of the intended new plan. As a result of the policy described above, the DRR field could not be activated for treatment however and the error was discovered and corrected. Other quality control barriers in place would have been unlikely to have detected this error. Conclusions: In these examples, a policy was adopted based on incident learning, which prevented several errors, at least one of which was potentially severe. These examples underscore the need for a rigorous, systematic incident learning process within each clinic. The experiences reported in this technical note demonstrate the value of near-miss incident reporting to improve patient safety.

60 APPLIED LIFE SCIENCES↗

Rhodium self-powered neutron detector as a suitable on-line thermal neutron flux monitor in BNCT treatments

Purpose: A rhodium self-powered neutron detector (Rh SPND) has been specifically developed by the Comision Nacional de Energia Atomica (CNEA) of Argentina to measure locally and in real time thermal neutron fluxes in patients treated with boron neutron capture therapy (BNCT). In this work, the thermal and epithermal neutron response of the Rh SPND was evaluated by studying the detector response to two different reactor spectra. In addition, during clinical trials of the BNCT Project of the CNEA, on-line neutron flux measurements using the specially designed detector were assessed. Methods: The first calibration of the detector was done with the well-thermalized neutron spectrum of the CNEA RA-3 reactor thermal column. For this purpose, the reactor spectrum was approximated by a Maxwell-Boltzmann distribution in the thermal energy range. The second calibration was done at different positions along the central axis of a water-filled cylindrical phantom, placed in the mixed thermal-epithermal neutron beam of CNEA RA-6 reactor. In this latter case, the RA-6 neutron spectrum had been well characterized by both calculation and measurement, and it presented some marked differences with the ideal spectrum considered for SPND calibrations at RA-3. In addition, the RA-6 neutron spectrum varied with depth in the water phantom and thus the percentage of the epithermal contribution to the total neutron flux changed at each measurement location. Local (one point-position) and global (several points-positions) and thermal and mixed-field thermal neutron sensitivities were determined from these measurements. Thermal neutron flux was also measured during BNCT clinical trials within the irradiation fields incident on the patients. In order to achieve this, the detector was placed on patient's skin at dosimetric reference points for each one of the fields. System stability was adequate for this kind of measurement. Results: Local mixed-field thermal neutron sensitivities and global thermal and mixed-field thermal neutron sensitivities derived from measurements performed at the RA-6 were compared and no significant differences were found. Global RA-6-based thermal neutron sensitivity showed agreement with pure thermal neutron sensitivity measurements performed in the RA-3 spectrum. Additionally, the detector response proved nearly unchanged by differences in neutron spectra from real (RA-6 BNCT beam) and ideal (considered for calibration calculations at RA-3) neutron source descriptions. The results confirm that the special design of the Rh SPND can be considered as having a pure thermal response for neutron spectra with epithermal-to-thermal flux ratios up to 12%. In addition, the linear response of the detector to thermal flux allows the use of a mixed-field thermal neutron sensitivity of 1.95 {+-} 0.05 x 10{sup -21} A n{sup -1}{center_dot}cm{sup 2}{center_dot}s. This sensitivity can be used in spectra with up to 21% epithermal-to-thermal flux ratio without significant error due to epithermal neutron and gamma induced effects. The values of the measured fluxes in clinical applications had discrepancies with calculated results that were in the range of -25% to +30%, which shows the importance of a local on-line independent measurement as part of a treatment planning quality control system. Conclusions: The usefulness of the CNEA Rh SPND for the on-line local measurement of thermal neutron flux on BNCT patients has been demonstrated based on an appropriate neutron spectra calibration and clinical applications.

07 ISOTOPE AND RADIATION SOURCES↗

Effect of natural ageing on volume stability of MSW and wood waste incineration residues

Highlights: ► Natural weathering on BA from MSW and wood waste incineration was evaluated. ► Type of mineral phases, pH and volume stability were considered. ► Weathering reactions effect in improved stability of the materials. - Abstract: This paper presents the results of a study on the effect of natural weathering on volume stability of bottom ash (BA) from municipal solid waste (MSW) and wood waste incineration. BA samples were taken at different steps of treatment (fresh, 4 weeks and 12 weeks aged) and then characterised for their chemical and mineralogical composition and for volume stability by means of the mineralogical test method (M HMVA-StB), which is part of the German quality control system for using aggregates in road construction (TL Gestein-StB 04). Changes of mineralogical composition with the proceeding of the weathering treatment were also monitored by leaching tests. At the end of the 12 weeks of treatment, almost all the considered samples resulted to be usable without restrictions in road construction with reference to the test parameter volume stability.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Using the metagenomics RAST server (MG-RAST) for analyzing shotgun metagenomes.

Shotgun metagenomics creates millions of fragments of short DNA reads, which are meaningless unless analyzed appropriately. The Metagenomics RAST server (MG-RAST) is a web-based, open source system that offers a unique suite of tools for analyzing these data sets. After de-replication and quality control, fragments are mapped against a comprehensive nonredundant database (NR). Phylogenetic and metabolic reconstructions are computed from the set of hits against the NR. The resulting data are made available for browsing, download, and most importantly, comparison against a comprehensive collection of public metagenomes. A submitted metagenome is visible only to the user, unless the user makes it public or shares with other registered users. Public metagenomes are available to all.

59 BASIC BIOLOGICAL SCIENCES↗

Assessment of the Current Level of Automation in the Manufacture of Fuel Cell Systems for Combined Heat and Power Applications

The U.S. Department of Energy (DOE) is interested in supporting manufacturing research and development (R&D) for fuel cell systems in the 10-1,000 kilowatt (kW) power range relevant to stationary and distributed combined heat and power applications, with the intent to reduce manufacturing costs and increase production throughput. To assist in future decision-making, DOE requested that theNational Renewable Energy Laboratory (NREL) provide a baseline understanding of the current levels of adoption of automation in manufacturing processes and flow, as well as of continuous processes. NREL identified and visited or interviewed key manufacturers, universities, and laboratories relevant to the study using a standard questionnaire. The questionnaire covered the current level ofvertical integration, the importance of quality control developments for automation, the current level of automation and source of automation design, critical balance of plant issues, potential for continuous cell manufacturing, key manufacturing steps or processes that would benefit from DOE support for manufacturing R&D, the potential for cell or stack design changes to support automation, andthe relationship between production volume and decisions on automation.

30 DIRECT ENERGY CONVERSION↗

FINAL SCIENTIFIC/TECHNICAL REPORT

Dynalene Inc has developed and patented a fuel cell coolant with the help of DOE SBIR Phase I and Phase II funding (Project DE-FG02-04ER83884). However, this coolant could only be produced in lab scale (500 ml to 2 L) due to problems in the optimization and scale-up of a nanoparticle ingredient. This project optimized the nanoparticle production process in 10 L and 100 L reactors (which translates to about 5000 gallons of coolant), optimized the filtration process for the nanoparticles, and develop a high throughput production as well as quality control method for the final coolant formulation. Scale-up of nanoparticle synthesis (using emulsion polymerization) is an extremely challenging task. Dynalene researchers, in collaboration with a university partner, identified all the parameters affecting the size, charge density and coagulation characteristics of the nanoparticles and then optimized these parameters to achieve the goals and the objectives of this project. Nanoparticle synthesis was demonstrated to be reproducible in the 10 L and 100 L scales.

08 HYDROGEN↗

Comparative quantification and statistical analysis of η′ and η precipitates in aluminum alloy AA7075-T651 by TEM and AFM

Quantification of nanometric precipitates in metallic alloys has been traditionally performed using transmission electron microscopy, which is nominally a low throughput technique. This work presents a comparative study of quantification of η′ and η precipitates in aluminum alloy AA7075-T651 using transmission electron microscopy (TEM) and non-contact atomic force microscopy (AFM). AFM quantification was compared with 2-D stereological results reported elsewhere. Also, a method was developed, using specialized software, to characterize nanometric size precipitates observed in dark-field TEM micrographs. Statistical analysis of the quantification results from both measurement techniques supports the use of AFM for precipitate characterization. Once the precipitate stoichiometry has been determined by appropriate analytical techniques like TEM, as it is the case for η′ and η in AA7075-T651, the relative ease with which specimens are prepared for AFM analysis could be advantageous in product and process development, and quality control, where a large number of samples are expected for analysis on a regular basis. - Highlights: • Nanometric MgZn{sub 2} precipitates in AA7075-T651 were characterized using AFM and TEM. • Phase-contrast AFM was used to differentiate metal matrix from MgZn{sub 2} precipitates. • TEM and AFM micrographs were analyzed using commercially available software. • AFM image analysis and TEM 2-D stereology render statistically equivalent results.

36 MATERIALS SCIENCE↗

Determination of Main Components of Glass-Forming Cu–Zr Alloys

A rapid procedure is developed for determination of copper and zirconium in their binary alloys Cu{sub 100–x}Zr{sub x} in the content ranges corresponding to the region of bulk amorphization (x = 30–70) using inductively coupled plasma atomic emission spectroscopy (ICP-AES). The spectrometer operating conditions are optimized, and the analytical spectral lines (Cu II 224.700 nm and Zr II 354.262 nm) are selected, as well as calibration method and sampling procedure: dissolution in the mixture of HNO{sub 3} and HF with addition of HCl, providing for the minimum standard deviation of the analytical signal. A procedure of oxygen determination by inert gas fusion technique and a procedure for determination of copper by spectrophotometry and zirconium by gravimetric analysis in a single sample together with quality control of ICP-AES are developed for the considered alloys. The results of analysis of Cu{sub 100–x}Zr{sub x} alloys according to the developed procedures agree well between themselves and accounting for adjustment of oxygen content agree within the error limits (not more than 0.5 wt %) with the added content of copper and zirconium upon synthesis.

36 MATERIALS SCIENCE↗

Quantitative imaging of graphene impedance with the near-field scanning microwave microscope.

Graphene has emerged as a promising material for high speed nano-electronics due to the relatively high carrier mobility that can be achieved. To further investigate electronic transport in graphene and reveal its potential for microwave applications, we employed a near-field scanning microwave microscope with the probe formed by an electrically open end of a 4 GHz half-lambda parallel-strip transmission line resonator. Because of the balanced probe geometry, our microscope allows for truly localized quantitative characterization of various bulk and low-dimensional materials, with the response region defined by the one micron spacing between the two metallic strips at the probe tip. The single- and few-layer graphene flakes were fabricated by a mechanical cleavage method on 300-nm-thick silicon dioxide grown on low resistivity Si wafer. The flake thickness was determined using both AFM and Raman microscopies. We observe clear correlation between the near-field microwave and far-field optical images of graphene produced by the probe resonant frequency shift and thickness-defined color gradation, respectively. We show that the microwave response of graphene flakes is determined by the local sheet impedance, which is found to be predominantly active. Furthermore, we apply a quantitative electrodynamic model relating the probe resonant frequency shift to 2D conductivity of single- and few-layer graphene. From fitting a model to the experimental data we evaluate graphene sheet resistance as a function of thickness. Near-field scanning microwave microscopy can simultaneously image location, geometry, thickness, and distribution of electrical properties of graphene without a need for device fabrication. The approach may be useful for design of graphene-based microwave transistors, quality control of large area graphene sheets, or investigation of chemical and electrical doping effects on graphene transport properties. We acknowledge support from the DOE Center for Integrated Nanotechnologies user support program (grant No.U2008A061), from the NASA NM Space Grant Consortium program, and from the LANL-NMT MOU program supported by UCDRD.

24 POWER TRANSMISSION AND DISTRIBUTION↗

BBMap: A Fast, Accurate, Splice-Aware Aligner

Alignment of reads is one of the primary computational tasks in bioinformatics. Of paramount importance to resequencing, alignment is also crucial to other areas - quality control, scaffolding, string-graph assembly, homology detection, assembly evaluation, error-correction, expression quantification, and even as a tool to evaluate other tools. An optimal aligner would greatly improve virtually any sequencing process, but optimal alignment is prohibitively expensive for gigabases of data. Here, we will present BBMap [1], a fast splice-aware aligner for short and long reads. We will demonstrate that BBMap has superior speed, sensitivity, and specificity to alternative high-throughput aligners bowtie2 [2], bwa [3], smalt, [4] GSNAP [5], and BLASR [6].

09 BIOMASS FUELS↗

The upstream open reading frame of cyclin-dependent kinase inhibitor 1A mRNA negatively regulates translation of the downstream main open reading frame

Highlights: Black-Right-Pointing-Pointer CDKN1A mRNA is a bona fide NMD substrate. Black-Right-Pointing-Pointer The uORF of CDKN1A mRNA is efficiently translated. Black-Right-Pointing-Pointer Translation of downstream main ORF is negatively regulated by translation of uORF in CDKN1A mRNA. -- Abstract: The first round of translation occurs on mRNAs bound by nuclear cap-binding complex (CBC), which is composed of nuclear cap-binding protein 80 and 20 (CBP80/20). During this round of translation, aberrant mRNAs are recognized and downregulated in abundance by nonsense-mediated mRNA decay (NMD), which is one of the mRNA quality control mechanisms. Here, our microarray analysis reveals that the level of cyclin-dependent kinase inhibitor 1A (CDKN1A; also known as Waf1/p21) mRNAs increases in cells depleted of cellular NMD factors. Intriguingly, CDKN1A mRNA contains an upstream open reading frame (uORF), which is a NMD-inducing feature. Using chimeric reporter constructs, we find that the uORF of CDKN1A mRNA negatively modulates translation of the main downstream ORF. These findings provide biological insights into the possible role of NMD in diverse biological pathways mediated by CDKN1A.

60 APPLIED LIFE SCIENCES↗

MO-AB-207-00: ACR Update in MR, CT, Nuclear Medicine, and Mammography

A goal of an imaging accreditation program is to ensure adequate image quality, verify appropriate staff qualifications, and to assure patient and personnel safety. Currently, more than 35,000 facilities in 10 modalities have been accredited by the American College of Radiology (ACR), making the ACR program one of the most prolific accreditation options in the U.S. In addition, ACR is one of the accepted accreditations required by some state laws, CMS/MIPPA insurance and others. Familiarity with the ACR accreditation process is therefore essential to clinical diagnostic medical physicists. Maintaining sufficient knowledge of the ACR program must include keeping up-to-date as the various modality requirements are refined to better serve the goals of the program and to accommodate newer technologies and practices. This session consists of presentations from authorities in four ACR accreditation modality programs, including magnetic resonance imaging, computed tomography, nuclear medicine, and mammography. Each speaker will discuss the general components of the modality program and address any recent changes to the requirements. Learning Objectives: To understand the requirements of the ACR MR Accreditation program. The discussion will include accreditation of whole-body general purpose magnets, dedicated extremity systems well as breast MRI accreditation. Anticipated updates to the ACR MRI Quality Control Manual will also be reviewed. To understand the requirements of the ACR CT accreditation program, including updates to the QC manual as well as updates through the FAQ process. To understand the requirements of the ACR nuclear medicine accreditation program, and the role of the physicist in annual equipment surveys and the set up and supervision of the routine QC program. To understand the current ACR MAP Accreditation requirement and present the concepts and structure of the forthcoming ACR Digital Mammography QC Manual and Program.

60 APPLIED LIFE SCIENCES↗

MO-AB-207-03: ACR Update in Nuclear Medicine

A goal of an imaging accreditation program is to ensure adequate image quality, verify appropriate staff qualifications, and to assure patient and personnel safety. Currently, more than 35,000 facilities in 10 modalities have been accredited by the American College of Radiology (ACR), making the ACR program one of the most prolific accreditation options in the U.S. In addition, ACR is one of the accepted accreditations required by some state laws, CMS/MIPPA insurance and others. Familiarity with the ACR accreditation process is therefore essential to clinical diagnostic medical physicists. Maintaining sufficient knowledge of the ACR program must include keeping up-to-date as the various modality requirements are refined to better serve the goals of the program and to accommodate newer technologies and practices. This session consists of presentations from authorities in four ACR accreditation modality programs, including magnetic resonance imaging, computed tomography, nuclear medicine, and mammography. Each speaker will discuss the general components of the modality program and address any recent changes to the requirements. Learning Objectives: To understand the requirements of the ACR MR Accreditation program. The discussion will include accreditation of whole-body general purpose magnets, dedicated extremity systems well as breast MRI accreditation. Anticipated updates to the ACR MRI Quality Control Manual will also be reviewed. To understand the requirements of the ACR CT accreditation program, including updates to the QC manual as well as updates through the FAQ process. To understand the requirements of the ACR nuclear medicine accreditation program, and the role of the physicist in annual equipment surveys and the set up and supervision of the routine QC program. To understand the current ACR MAP Accreditation requirement and present the concepts and structure of the forthcoming ACR Digital Mammography QC Manual and Program.

60 APPLIED LIFE SCIENCES↗

MO-AB-207-04: ACR Update in Mammography

A goal of an imaging accreditation program is to ensure adequate image quality, verify appropriate staff qualifications, and to assure patient and personnel safety. Currently, more than 35,000 facilities in 10 modalities have been accredited by the American College of Radiology (ACR), making the ACR program one of the most prolific accreditation options in the U.S. In addition, ACR is one of the accepted accreditations required by some state laws, CMS/MIPPA insurance and others. Familiarity with the ACR accreditation process is therefore essential to clinical diagnostic medical physicists. Maintaining sufficient knowledge of the ACR program must include keeping up-to-date as the various modality requirements are refined to better serve the goals of the program and to accommodate newer technologies and practices. This session consists of presentations from authorities in four ACR accreditation modality programs, including magnetic resonance imaging, computed tomography, nuclear medicine, and mammography. Each speaker will discuss the general components of the modality program and address any recent changes to the requirements. Learning Objectives: To understand the requirements of the ACR MR Accreditation program. The discussion will include accreditation of whole-body general purpose magnets, dedicated extremity systems well as breast MRI accreditation. Anticipated updates to the ACR MRI Quality Control Manual will also be reviewed. To understand the requirements of the ACR CT accreditation program, including updates to the QC manual as well as updates through the FAQ process. To understand the requirements of the ACR nuclear medicine accreditation program, and the role of the physicist in annual equipment surveys and the set up and supervision of the routine QC program. To understand the current ACR MAP Accreditation requirement and present the concepts and structure of the forthcoming ACR Digital Mammography QC Manual and Program.

60 APPLIED LIFE SCIENCES↗