Search NASA⌕ Search

SEARCH · Search NASA

Results for “Random Effects”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Comparison of the compressive strengths for stitched and toughened composite systems

The compression strength of a stitched and a toughened matrix graphite/epoxy composite was determined and compared to a baseline unstitched untoughened composite. Two different layups with a variety of test lengths were tested under both ambient and hot/wet conditions. No significant difference in strength was seen for the different materials when the gage lengths of the specimens were long enough to lead to a buckling failure. For shorter specimens, a 30 percent reduction in strength from the baseline was seen due to stitching for both a 48-ply quasi-isotropic and a (0/45/0/-45/90/-45/0/45/0)s laminate. Analysis of the results suggested that the decrease in strength was due to increased fiber misalignment due to the stitches. An observed increasing strength with decreasing gage length, which was seen for all materials, was explained with a size effect model. The model assumed a random distribution of flaws (misaligned fibers). The toughened materials showed a small increase in strength over the baseline material for both laminates presumably due to the compensating effects of a more compliant matrix and straighter fibers in the toughened material. The hot/wet strength of the stitched and baseline material fell 30 percent below their ambient strengths for shorter, nonbuckling specimen, while the strength of the toughened matrix material only fell 20 percent. Video images of the failing specimen were recorded and showed local failures prior to global collapse of the specimen. These images support the theory of a random distribution of flaws controlling composite failure. Failed specimen appearance, however, seems to be a misleading indication of the cause of failure.

Reeder, James R.↗

Comparison of the Compressive Strengths for Stitched and Toughened Composite Systems

The compression strength of a stitched and a toughened matrix graphite/epoxy composite was determined and compared to a baseline unstitched untoughened composite. Two different layups with a variety of test lengths were tested under both ambient and hot/wet conditions. No significant difference in strength was seen for the different materials when the gage lengths of the specimens were long enough to lead to a buckling failure. For shorter specimens, a 30% reduction in strength from the baseline was seen due to stitching for both a 48-ply quasi-isotropic and a (0/45/0/-45/90/-45/0/45/0)s laminate. Analysis of the results suggested that the decrease in strength was due to increased fiber misalignment due to the stitches. An observed increasing strength with decreasing gage length, which was seen for all materials, was explained with a size effect model. The model assumed a random distribution of flaws (misaligned fibers). The toughened material showed a small increase in strength over the baseline material for both laminates presumably due to the compensating effects of a more compliant matrix and straighter fibers in the toughened material. The hot/wet strength of the stitched and baseline material fell 30% below their ambient strengths for shorter, non-buckling specimen, while the strength of the toughened matrix material only fell 20%. Video images of the failing specimen were recorded and showed local failures prior to global collapse of the specimen. These images support the theory of a random distribution of flaws controlling composite failure. Failed specimen appearance however, seems to be a misleading indication of the cause of failure.

Reeder, James R.↗

Exotic modes of excitation in proton rich nuclei

The framework of relativistic energy density functional has been applied in description of excitation phenomena in nuclei close to the proton drip line. In particular, low-lying dipole excitations have been studied using relativistic quasiparticle random phase approximation, based on effective Lagrangians with density dependent meson nucleon couplings. In the isovector dipole channel, the occurrence of pronounced low-lying dipole peaks is predicted, corresponding to the proton pygmy dipole resonance. Since this exotic mode still awaits its experimental confirmation, systematic calculations have been conducted within a pool of neutron deficient nuclei, in order to identify the best possible candidates for measurements.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

On the Neutrino Self Refraction Problem from a Many-Body Perspective

We consider a dense neutrino gas as a many body system by taking into account both vacuum oscillations and self interactions of neutrinos. We show that the exact many body Hamiltonian which describes the flavor oscillations of such a dense neutrino gas has many constants of motion whose eigenvalues represent a set of good quantum numbers. However, if one adopts the random phase approximation as an effective one particle description, these operators are no longer conserved (i.e. they cease to represent good quantum numbers) although their expectation values are still conserved.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The Effects of a Nearly 100% Duty Cycle in Observations of Solar Oscillations

Power spectra of window functions with duty cycles between 80% and 99% and with randomly spaced gaps are compared and their effect on observations of solar oscillations are discussed. It is found that for all the cases, observations of solar oscillations would not be severely impacted as long as the gap structure is random rather than periodic.

Hill, F.↗

Thermal property tuning in aligned carbon nanotube films and random entangled carbon nanotube films by ion irradiation

Ion irradiation effects on thermal property changes are compared between aligned carbon nanotube (A-CNT) films and randomly entangled carbon nanotube (R-CNT) films. After H, C, and Fe ion irradiation, a focusing ion beam with sub-mm diameter is used as a heating source, and an infrared signal is recorded to extract thermal conductivity. Ion irradiation decreases thermal conductivity of A-CNT films, but increases that of R-CNT films. We explain the opposite trends by the fact that neighboring CNT bundles are loosely bonded in A-CNT films, which makes it difficult to create inter-tube linkage/bonding upon ion irradiation. In a comparison, in R-CNT films, which have dense tube networking, carbon displacements are easily trapped between touching tubes and act as inter-tube linkage to promote off-axial phonon transport. The enhancement overcomes the phonon transport loss due to phonon-defect scattering along the axial direction. A model is established to explain the dependence of thermal conductivity changes on ion irradiation parameters including ion species, energies, and current.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Analytic Minkowski functionals of the cosmic microwave background: Second-order non-Gaussianity with bispectrum and trispectrum

Analytic formulas of Minkowski functionals in two-dimensional random fields are derived, including effects of second-order non-Gaussianity in the presence of both the bispectrum and trispectrum. The set of formulas provides a promising method to constrain the primordial non-Gaussianity of the universe by temperature fluctuations in the cosmic microwave background radiation. In a case of local-type non-Gaussianity, the Minkowski functionals are analytically given by powers of quadratic and cubic parameters, f{sub NL} and g{sub NL} (and {tau}{sub NL}). Our formulas are not restricted to this particular model, and applicable to a wide class of non-Gaussian models. The analytic formulas are compared to numerical evaluations from non-Gaussian realizations of temperature maps, showing very good agreement.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Retention modeling for ultra-thin density of Cu-based conductive bridge random access memory (CBRAM)

We investigate the effect of Cu concentration On-state resistance retention characteristics of W/Cu/Ti/HfO{sub 2}/Pt memory cell. The development of RRAM device for application depends on the understanding of the failure mechanism and the key parameters for device optimization. In this study, we develop analytical expression for cations (Cu{sup +}) diffusion model using Gaussian distribution for detailed analysis of data retention time at high temperature. It is found that the improvement of data retention time depends not only on the conductive filament (CF) size but also on Cu atoms concentration density in the CF. Based on the simulation result, better data retention time is observed for electron wave function associated with Cu{sup +} overlap and an extended state formation. This can be verified by analytical calculation of Cu atom defects inside the filament, based on Cu{sup +} diffusion model. The importance of Cu diffusion for the device reliability and the corresponding local temperature of the filament were analyzed by COMSOL Multiphysics simulation.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Evaluation of Finite Impulse Response Filters for Turbulence Effects on Sonic Booms

Turbulence effects on sonic booms lead to random variability of sonic boom waveforms measured on the ground, complicating the prediction of such waveforms using sonic boom propagation codes that do not account for turbulence effects. The NASA PCBoom software is one such code shown to accurately predict sonic booms above the atmospheric boundary layer but not those on the ground. Analyses of measured sonic booms show that, on average, the turbulence effects result in sonic boom loudness reduction, on average, that increases with propagation distance and turbulence strength. To efficiently account for such effects, a signal processing-based approach has been developed at NASA using finite impulse response filters derived from predicted waveforms by solving a nonlinear parabolic equation. Analyses indicate that the mean loudness reduction obtained using the filters does not increase with propagation distance or with increasing turbulence strength, in disagreement with flight test data. An alternative approach to the filters is currently under development employing the multiple scattering theory (MST) of wave propagation. Available results from the physics-based MST approach are used to evaluate the predictive capability of the filters, suggesting that the filters can severely underestimate the prediction of the MST approach.

sonic booms↗

Evaluation of Finite Impulse Response Filters for Turbulence Effects on Sonic Booms

Turbulence effects on sonic booms lead to random variability of sonic boom waveforms measured on the ground, complicating the prediction of such waveforms using sonic boom propagation codes that do not account for turbulence effects. The NASA PCBoom software is one such code shown to accurately predict sonic booms above the atmospheric boundary layer but not those on the ground. Analyses of measured sonic booms show that, on average, the turbulence effects result in sonic boom loudness reduction, on average, that increases with propagation distance and turbulence strength. To efficiently account for such effects, a signal processing-based approach has been developed at NASA using finite impulse response filters derived from predicted waveforms by solving a nonlinear parabolic equation. Analyses indicate that the mean loudness reduction obtained using the filters does not increase with propagation distance or with increasing turbulence strength, in disagreement with flight test data. An alternative approach to the filters is currently under development employing the multiple scattering theory (MST) of wave propagation. Available results from the physics-based MST approach are used to evaluate the predictive capability of the filters, suggesting that the filters can severely underestimate the prediction of the MST approach.

sonic booms↗

Terpolymer Donor with Inside Alkyl Substituents on Thiophene π ‐Bridges toward Thiazolothiazole A 2 ‐Unit Enables 18.21% Efficiency of Polymer Solar Cells

Abstract PM6 is a widely used D–A copolymer donor in the polymer solar cells (PSCs). Incorporating second electron‐withdrawing (A 2 ) units into PM6 backbone by ternary D–A 1 –D–A 2 random copolymerization strategy is an effective approach to further improve its photovoltaic performance. Here, the authors synthesize the PM6‐based terpolymers by introducing thiazolothiazole as the A 2 units connecting with thiophene π‐bridges attaching alkyl substituent towards the A 2 unit (PMT‐CT) or towards D‐unit (PMT‐FT), and study the effect of the alkyl substituent position on the photovoltaic performance of them. Two terpolymers PMT‐FT‐10 and PMT‐CT‐10 are obtained by incorporating 10% A 2 units in the terpolymers. The film of PMT‐CT‐10 shows slightly up‐shifted highest occupied molecular orbital (HOMO) energy levels while better co‐planar structure than that of PMT‐FT‐10. Meanwhile, the PMT‐CT‐10:Y6 blend film exhibits better molecular packing properties, more proper phase separation and more balanced hole and electron mobilities, which are beneficial to more efficient exciton dissociation, efficient charge transport and weaker bimolecular recombination. Consequently, the PMT‐CT‐10 based PSCs obtain the highest power conversion efficiency of 18.21%. The results indicate that side chain position on the thiophene π‐bridges influence the device performance of the terpolymer donors, and PMT‐CT‐10 is a high efficiency polymer donor for the PSCs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Reduced Mortality With Partial-Breast Irradiation for Early Breast Cancer: A Meta-Analysis of Randomized Trials

Purpose: With earlier detection and more effective treatment, mortality from breast cancer continues to fall and it has become increasingly important to reduce the toxicity of treatments. Partial-breast radiation therapy, which focuses radiation to the tumor bed, may achieve this aim. We analyzed mortality differences in randomized trials of partial-breast irradiation (PBI). Methods and Materials: We included data from published randomized trials of PBI (alone or as part of a risk-adapted approach) versus whole-breast irradiation (WBI) for invasive breast cancer suitable for breast-conserving therapy. We identified trials using PubMed and Google searches with the terms “partial breast irradiation” OR “intraoperative radiotherapy” OR “IMRT” OR (“accelerated” AND “radiation”) AND “randomised/randomized,” as well as through discussion with colleagues in the field. We calculated the proportion of patients who had events in each randomized arm at 5 years' follow-up and created a forest plot using Stata, version 14.1. Results: We identified 9 randomized trials of PBI versus WBI in invasive breast cancer; 5-year outcomes were available for non–breast cancer mortality in 5 trials (n=4489) and for breast cancer mortality in 4 trials (n=4231). The overall mortality was 4.9%. There was no detectable heterogeneity between the trials for any of the outcomes. There was no difference in the proportion of patients dying of breast cancer (difference, 0.000% [95% confidence interval (CI), −0.7 to +0.7]; P=.999). Non–breast cancer mortality with PBI was lower than with WBI (difference, 1.1% [95% CI, −2.1% to −0.2%]; P=.023). Total mortality with PBI was also lower than with WBI (difference, 1.3% [95% CI, −2.5% to 0.0%]; P=.05). Conclusions: Use of PBI instead of WBI in selected patients results in a lower 5-year non–breast cancer and overall mortality, amounting to a 25% reduction in relative terms. This information should be included when breast-conserving therapy is proposed to a patient.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Theory of a Planckian Metal

We present a lattice model of fermions with N flavors and random interactions that describes a Planckian metal at low temperatures T → 0 in the solvable limit of large N. We begin with quasiparticles around a Fermi surface with effective mass m* and then include random interactions that lead to fermion spectral functions with frequency scaling with k B T/ℏ. Here, the resistivity ρ obeys the Drude formula ρ = m*/(ne 2 τ tr ), where n is the density of fermions, and the transport scattering rate is 1/τ tr = fk B T/ℏ; we find f of order unity and essentially independent of the strength and form of the interactions. The random interactions are a generalization of the Sachdev-Ye-Kitaev models; it is assumed that processes nonresonant in the bare quasiparticle energies only renormalize m*, while resonant processes are shown to produce the Planckian behavior.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Modeling and simulation of electronic structure, material interface and random doping in nano-electronic devices

The miniaturization of nano-scale electronic devices, such as metal oxide semiconductor field effect transistors (MOSFETs), has given rise to a pressing demand in the new theoretical understanding and practical tactic for dealing with quantum mechanical effects in integrated circuits. Modeling and simulation of this class of problems have emerged as an important topic in applied and computational mathematics. This work presents mathematical models and computational algorithms for the simulation of nano-scale MOSFETs. We introduce a unified two-scale energy functional to describe the electrons and the continuum electrostatic potential of the nano-electronic device. This framework enables us to put microscopic and macroscopic descriptions in an equal footing at nano-scale. By optimization of the energy functional, we derive consistently coupled Poisson-Kohn-Sham equations. Additionally, layered structures are crucial to the electrostatic and transport properties of nano-transistors. A material interface model is proposed for more accurate description of the electrostatics governed by the Poisson equation. Finally, a new individual dopant model that utilizes the Dirac delta function is proposed to understand the random doping effect in nano-electronic devices. Two mathematical algorithms, the matched interface and boundary (MIB) method and the Dirichlet-to-Neumann mapping (DNM) technique, are introduced to improve the computational efficiency of nano-device simulations. Electronic structures are computed via subband decomposition and the transport properties, such as the I-V curves and electron density, are evaluated via the non-equilibrium Green's functions (NEGF) formalism. Two distinct device configurations, a double-gate MOSFET and a four-gate MOSFET, are considered in our three-dimensional numerical simulations. For these devices, the current fluctuation and voltage threshold lowering effect induced by the discrete dopant model are explored. Numerical convergence and model well-posedness are also investigated in the present work.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Pain in percutaneous liver core-needle biopsy: a randomized trial comparing the intercostal and subcostal approaches

Purpose: Effective pain control during and after percutaneous core needle liver biopsy is important with regard to ethical considerations and patient comfort. In this randomized double-blind study, we compared post-biopsy pain in the patients undergoing liver core-needle biopsy using either subcostal or intercostal approaches. Methods: All patients referred for ultrasound-guided CNLB between July 2017 and January 2018 to our interventional radiology department were randomized into two groups. Biopsy was performed through intercostal approach in the first group and through subcostal approach in the second group. The intensity of pain 0, 2, and 4 h after the procedure was compared in two groups using a 100-mm visual analogue scale. All biopsies were performed without procedural IV sedation. If patients’ discomfort demanded administration of IV analgesics during or after the procedure, then the patients were excluded from the study. Results: In patients without routine procedural IV sedation, there was no significant difference in the pain level between the intercostal and subcostal groups immediately after the procedure (p = 0.055), but we found a significant difference in the pain level between the two groups 2 (7.5 mm, p = 0.001) and 4 (2 mm, p = 0.001) h after the procedure. Conclusion: The minimum amount of change in the VAS score that is considered clinically important is 13 mm on a 100-mm scale. Pain differences at 2 and 4 h in the two groups in this study were statistically but not clinically significant. Therefore, the authors suggest the use of subcostal route for ultrasound-guided liver biopsy whenever possible, but the results do not warrant the routine use of post-procedure analgesics in whom biopsy is performed via intercostal route.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

EFFECT OF DUST ON Ly{alpha} PHOTON TRANSFER IN AN OPTICALLY THICK HALO

We investigate the effects of dust on Ly{alpha} photons emergent from an optically thick medium by solving the integro-differential equation of radiative transfer of resonant photons. To solve the differential equations numerically, we use the weighted essentially non-oscillatory method. Although the effects of dust on radiative transfer are well known, the resonant scattering of Ly{alpha} photons makes the problem non-trivial. For instance, if the medium has an optical depth of dust absorption and scattering of {tau}{sub a} >> 1, {tau} >> 1, and {tau} >> {tau}{sub a}, the effective absorption optical depth in a random walk scenario would be equal to {radical}({tau}{sub a}({tau}{sub a}+{tau})). We show, however, that for a resonant scattering at frequency {nu}{sub 0}, the effective absorption optical depth would be even larger than {tau}({nu}{sub 0}). If the cross section of dust scattering and absorption is frequency-independent, the double-peaked structure of the frequency profile given by the resonant scattering is basically dust-independent. That is, dust causes neither narrowing nor widening of the width of the double-peaked profile. One more result is that the timescales of the Ly{alpha} photon transfer in an optically thick halo are also basically independent of the dust scattering, even when the scattering is anisotropic. This is because those timescales are mainly determined by the transfer in the frequency space, while dust scattering, either isotropic or anisotropic, does not affect the behavior of the transfer in the frequency space when the cross section of scattering is wavelength-independent. This result does not support the speculation that dust will lead to the smoothing of the brightness distribution of a Ly{alpha} photon source with an optically thick halo.

79 ASTRONOMY AND ASTROPHYSICS↗

ytopt: Autotuning Scientific Applications for Energy Efficiency at Large Scales

As we enter the exascale computing era, efficiently utilizing power and optimizing the performance of scientific applications under power and energy constraints has become critical and challenging. We propose a low-overhead autotuning framework to autotune performance and energy for various hybrid MPI/OpenMP scientific applications at large scales and to explore the tradeoffs between application runtime and power/energy for energy efficient application execution, then use this framework to autotune four ECP proxy applications—XSBench, AMG, SWFFT, and SW4lite. Our approach uses Bayesian optimization with a Random Forest surrogate model to effectively search parameter spaces with up to 6 million different configurations on two large-scale HPC production systems, Theta at Argonne National Laboratory and Summit at Oak Ridge National Laboratory. The experimental results show that our autotuning framework at large scales has low overhead and achieves good scalability. Using the proposed autotuning framework to identify the best configurations, we achieve up to 91.59% performance improvement, up to 21.2% energy savings, and up to 37.84% EDP (energy delay product) improvement on up to 4096 nodes.

Autotuning↗

Preliminary Toxicity Analysis of 3-Dimensional Conformal Radiation Therapy Versus Intensity Modulated Radiation Therapy on the High-Dose Arm of the Radiation Therapy Oncology Group 0126 Prostate Cancer Trial

Purpose: To give a preliminary report of clinical and treatment factors associated with toxicity in men receiving high-dose radiation therapy (RT) on a phase 3 dose-escalation trial. Methods and Materials: The trial was initiated with 3-dimensional conformal RT (3D-CRT) and amended after 1 year to allow intensity modulated RT (IMRT). Patients treated with 3D-CRT received 55.8 Gy to a planning target volume that included the prostate and seminal vesicles, then 23.4 Gy to prostate only. The IMRT patients were treated to the prostate and proximal seminal vesicles to 79.2 Gy. Common Toxicity Criteria, version 2.0, and Radiation Therapy Oncology Group/European Organization for Research and Treatment of Cancer late morbidity scores were used for acute and late effects. Results: Of 763 patients randomized to the 79.2-Gy arm of Radiation Therapy Oncology Group 0126 protocol, 748 were eligible and evaluable: 491 and 257 were treated with 3D-CRT and IMRT, respectively. For both bladder and rectum, the volumes receiving 65, 70, and 75 Gy were significantly lower with IMRT (all P<.0001). For grade (G) 2+ acute gastrointestinal/genitourinary (GI/GU) toxicity, both univariate and multivariate analyses showed a statistically significant decrease in G2+ acute collective GI/GU toxicity for IMRT. There were no significant differences with 3D-CRT or IMRT for acute or late G2+ or 3+ GU toxicities. Univariate analysis showed a statistically significant decrease in late G2+ GI toxicity for IMRT (P=.039). On multivariate analysis, IMRT showed a 26% reduction in G2+ late GI toxicity (P=.099). Acute G2+ toxicity was associated with late G3+ toxicity (P=.005). With dose–volume histogram data in the multivariate analysis, RT modality was not significant, whereas white race (P=.001) and rectal V70 ≥15% were associated with G2+ rectal toxicity (P=.034). Conclusions: Intensity modulated RT is associated with a significant reduction in acute G2+ GI/GU toxicity. There is a trend for a clinically meaningful reduction in late G2+ GI toxicity with IMRT. The occurrence of acute GI toxicity and large (>15%) volumes of rectum >70 Gy are associated with late rectal toxicity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗