Search NASA⌕ Search

SEARCH · Search NASA

Results for “Reconstruction algorithms”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

GPU-accelerated multitiered iterative phasing algorithm for fluctuation X-ray scattering

The multitiered iterative phasing (MTIP) algorithm is used to determine the biological structures of macromolecules from fluctuation scattering data. It is an iterative algorithm that reconstructs the electron density of the sample by matching the computed fluctuation X-ray scattering data to the external observations, and by simultaneously enforcing constraints in real and Fourier space. This paper presents the first ever MTIP algorithm acceleration efforts on contemporary graphics processing units (GPUs). The Compute Unified Device Architecture (CUDA) programming model is used to accelerate the MTIP algorithm on NVIDIA GPUs. The computational performance of the CUDA-based MTIP algorithm implementation outperforms the CPU-based version by an order of magnitude. Furthermore, the Heterogeneous-Compute Interface for Portability (HIP) runtime APIs are used to demonstrate portability by accelerating the MTIP algorithm across NVIDIA and AMD GPUs.

97 MATHEMATICS AND COMPUTING↗

Determining the memory kernel from a fixed point measurement data for a parabolic equation with memory effect

We consider an inverse problem for a parabolic equation with memory effect. This inverse problem aims to identify the memory kernel function from a fixed point measurement data. Based on the fixed point arguments, we derive the global in time existence and uniqueness of our inverse problem. Moreover, we present a numerical algorithm to reconstruct the memory kernel function. Numerical simulations show the effectiveness of the proposed method.

97 MATHEMATICS AND COMPUTING↗

X-ray tomography of large objects with limited measurement angle

In this paper we present an efficient implementation of an algorithm for reconstructing a 3D volume from limited angle projection data, based on statistical inversion theory. We demonstrate the strength of the method for detecting structural defects in large composite aerospace components, whose dimensions prevent acquiring measurements over the full circle. In comparison with a number of other tomographic reconstruction methods that can be applied to the limited angle case, such as tomosynthesis or simultaneous algebraic reconstruction technique (SART), we achieve superior depth resolution with reduced noise and artifacts.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Piecewise-Constant-Model-Based Interior Tomography Applied to Dentin Tubules

Dentin is a hierarchically structured biomineralized composite material, and dentin’s tubules are difficult to study in situ. Nano-CT provides the requisite resolution, but the field of view typically contains only a few tubules. Using a plate-like specimen allows reconstruction of a volume containing specific tubules from a number of truncated projections typically collected over an angular range of about 140°, which is practically accessible. Classical computed tomography (CT) theory cannot exactly reconstruct an object only from truncated projections, needless to say a limited angular range. Recently, interior tomography was developed to reconstruct a region-of-interest (ROI) from truncated data in a theoretically exact fashion via the total variation (TV) minimization under the condition that the ROI is piecewise constant. In this paper, we employ a TV minimization interior tomography algorithm to reconstruct interior microstructures in dentin from truncated projections over a limited angular range. Compared to the filtered backprojection (FBP) reconstruction, our reconstruction method reduces noise and suppresses artifacts. Volume rendering confirms the merits of our method in terms of preserving the interior microstructure of the dentin specimen.

59 BASIC BIOLOGICAL SCIENCES↗

ICER-3D Hyperspectral Image Compression Software

Software has been developed to implement the ICER-3D algorithm. ICER-3D effects progressive, three-dimensional (3D), wavelet-based compression of hyperspectral images. If a compressed data stream is truncated, the progressive nature of the algorithm enables reconstruction of hyperspectral data at fidelity commensurate with the given data volume. The ICER-3D software is capable of providing either lossless or lossy compression, and incorporates an error-containment scheme to limit the effects of data loss during transmission. The compression algorithm, which was derived from the ICER image compression algorithm, includes wavelet-transform, context-modeling, and entropy coding subalgorithms. The 3D wavelet decomposition structure used by ICER-3D exploits correlations in all three dimensions of sets of hyperspectral image data, while facilitating elimination of spectral ringing artifacts, using a technique summarized in "Improving 3D Wavelet-Based Compression of Spectral Images" (NPO-41381), NASA Tech Briefs, Vol. 33, No. 3 (March 2009), page 7a. Correlation is further exploited by a context-modeling subalgorithm, which exploits spectral dependencies in the wavelet-transformed hyperspectral data, using an algorithm that is summarized in "Context Modeler for Wavelet Compression of Hyperspectral Images" (NPO-43239), which follows this article. An important feature of ICER-3D is a scheme for limiting the adverse effects of loss of data during transmission. In this scheme, as in the similar scheme used by ICER, the spatial-frequency domain is partitioned into rectangular error-containment regions. In ICER-3D, the partitions extend through all the wavelength bands. The data in each partition are compressed independently of those in the other partitions, so that loss or corruption of data from any partition does not affect the other partitions. Furthermore, because compression is progressive within each partition, when data are lost, any data from that partition received prior to the loss can be used to reconstruct that partition at lower fidelity. By virtue of the compression improvement it achieves relative to previous means of onboard data compression, this software enables (1) increased return of hyperspectral scientific data in the presence of limits on the rates of transmission of data from spacecraft to Earth via radio communication links and/or (2) reduction in spacecraft radio-communication power and/or cost through reduction in the amounts of data required to be downlinked and stored onboard prior to downlink. The software is also suitable for compressing hyperspectral images for ground storage or archival purposes.

Xie, Hua↗

SU-D-206-01: Employing a Novel Consensus Optimization Strategy to Achieve Iterative Cone Beam CT Reconstruction On a Multi-GPU Platform

Purpose: While compressed sensing-based cone-beam CT (CBCT) iterative reconstruction techniques have demonstrated tremendous capability of reconstructing high-quality images from undersampled noisy data, its long computation time still hinders wide application in routine clinic. The purpose of this study is to develop a reconstruction framework that employs modern consensus optimization techniques to achieve CBCT reconstruction on a multi-GPU platform for improved computational efficiency. Methods: Total projection data were evenly distributed to multiple GPUs. Each GPU performed reconstruction using its own projection data with a conventional total variation regularization approach to ensure image quality. In addition, the solutions from GPUs were subject to a consistency constraint that they should be identical. We solved the optimization problem with all the constraints considered rigorously using an alternating direction method of multipliers (ADMM) algorithm. The reconstruction framework was implemented using OpenCL on a platform with two Nvidia GTX590 GPU cards, each with two GPUs. We studied the performance of our method and demonstrated its advantages through a simulation case with a NCAT phantom and an experimental case with a Catphan phantom. Result: Compared with the CBCT images reconstructed using conventional FDK method with full projection datasets, our proposed method achieved comparable image quality with about one third projection numbers. The computation time on the multi-GPU platform was ∼55 s and ∼ 35 s in the two cases respectively, achieving a speedup factor of ∼ 3.0 compared with single GPU reconstruction. Conclusion: We have developed a consensus ADMM-based CBCT reconstruction method which enabled performing reconstruction on a multi-GPU platform. The achieved efficiency made this method clinically attractive.

60 APPLIED LIFE SCIENCES↗

Robust statistical reconstruction for charged particle tomography

Systems and methods for charged particle detection including statistical reconstruction of object volume scattering density profiles from charged particle tomographic data to determine the probability distribution of charged particle scattering using a statistical multiple scattering model and determine a substantially maximum likelihood estimate of object volume scattering density using expectation maximization (ML/EM) algorithm to reconstruct the object volume scattering density. The presence of and/or type of object occupying the volume of interest can be identified from the reconstructed volume scattering density profile. The charged particle tomographic data can be cosmic ray muon tomographic data from a muon tracker for scanning packages, containers, vehicles or cargo. The method can be implemented using a computer program which is executable on a computer.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Resolving boosted jets with XCone

We show how the recently proposed XCone jet algorithm smoothly interpolates between resolved and boosted kinematics. When using standard jet algorithms to reconstruct the decays of hadronic resonances like top quarks and Higgs bosons, one typically needs separate analysis strategies to handle the resolved regime of well-separated jets and the boosted regime of fat jets with substructure. XCone, by contrast, is an exclusive cone jet algorithm that always returns a fixed number of jets, so jet regions remain resolved even when (sub)jets are overlapping in the boosted regime. In this paper, we perform three LHC case studies $-$ dijet resonances, Higgs decays to bottom quarks, and all-hadronic top pairs$-$ that demonstrate the physics applications of XCone over a wide kinematic range.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Electromagnetic Calorimeter of the Belle-II Detector

The electromagnetic calorimeter for the Belle-II detector is briefly described. The algorithm of reconstruction of amplitude and time of calorimeter signals is described. The status of preparation of the electromagnetic calorimeter for the data-taking is presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Inference of response functions with the help of machine-learning algorithms

Response functions are a key quantity to describe the near-equilibrium dynamics of strongly interacting many-body systems. Recent techniques that attempt to overcome the challenges of calculating these ab initio have employed expansions in terms of orthogonal polynomials. We employ a neural network prediction algorithm to reconstruct a response function 𝑆⁡(𝜔) defined over a range in frequencies 𝜔. Here, we represent the calculated response function as a truncated Chebyshev series whose coefficients can be optimized to reduce the representation error. We compare the quality of response functions obtained using coefficients calculated using a neural network (NN) algorithm with those computed using the Gaussian integral transform (GIT) method. In the regime where only a small number of terms in the Chebyshev series are retained, we find that the NN scheme outperforms the GIT method.

Kurkcuoglu, Doga Murat [Fermi National Accelerator↗

Variational approach to quantum state tomography based on maximal entropy formalism

Quantum state tomography is an integral part of quantum computation and offers the starting point for the validation of various quantum devices. One of the central tasks in the field of state tomography is to reconstruct, with high fidelity, the quantum states of a quantum system. From an experiment on a real quantum device, one can obtain the mean measurement values of different operators. With such data as input, in this report we employ the maximal entropy formalism to construct the least biased mixed quantum state that is consistent with the given set of expectation values. Even though, in principle, the reported formalism is quite general and should work for an arbitrary set of observables, in practice we shall demonstrate the efficacy of the algorithm on an informationally complete (IC) set of Hermitian operators. Such a set possesses the advantage of uniquely specifying a single quantum state from which the experimental measurements have been sampled and hence renders the rare opportunity not only to construct a least-biased quantum state but even replicate the exact state prepared experimentally within a preset tolerance. Here, the primary workhorse of the algorithm is reconstructing an energy function which we designate as the effective Hamiltonian of the system, and parameterizing it with Lagrange multipliers, according to the formalism of maximal entropy. These parameters are thereafter optimized variationally so that the reconstructed quantum state of the system converges to the true quantum state within an error threshold. To this end, we employ a parameterized quantum circuit and a hybrid quantum-classical variational algorithm to obtain such a target state, making our recipe easily implementable on a near-term quantum device.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Elastic and resonance structures of the nucleon from the hadronic tensor in lattice QCD: Implications for neutrino-nucleon scattering and hadron physics

We compute the Euclidean hadronic tensor from charge density operators and extract elastic and resonance structures by employing exponential fits to the four-point function correlator, as well as a Bayesian reconstruction inverse algorithm to obtain the corresponding spectral density for qualitative comparison. We present the determination of the nucleon’s Sachs electric form factor using the hadronic tensor formalism and verify that it is consistent with that from the conventional three-point function calculation. Beyond the elastic peak, we observe a structure located approximately 0.5–0.7 GeV above the nucleon mass in the Bayesian reconstruction. This structure is interpreted as a mixture of the Roper resonance [𝑁⁡(1440)], and states with both positive and negative parities in this mass region, as well as multihadron states. Assuming the observed structure is dominated by 𝐽 𝑃 = 1/2 ± states, we extract the transition electric form factor 𝐺$^*_𝐸$⁡(𝑄 2 ) and the corresponding longitudinal helicity amplitude 𝑆 1/2 ⁡(𝑄 2 ), and compare them with those determined from the CLAS experimental data of nucleon-to-Roper transition. Although fitting to the four-point correlation function or using the inverse algorithm does not resolve individual resonances, it nevertheless enables the determination of total inclusive lepton–nucleon scattering cross sections in appropriate energy bins. This lattice QCD calculation presents the first major step toward studying the inclusive 𝑁 → 𝑋 contributions within the hadronic tensor formalism.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Sci—Sat AM: Stereo — 01: 3D Pre-treatment Dose Verification for Stereotactic Body Radiation Therapy Patients

Radical treatment techniques such as stereotactic body radiation therapy (SBRT) are becoming popular and they involve delivery of large doses in fewer fractions. Due to this feature of SBRT, a high-resolution, pre-treatment dose verification method that makes use of a 3D patient representation would be appropriate. Such a technique will provide additional information about dose delivered to the target volume(s) and organs-at-risk (OARs) in the patient volume compared to 2D verification methods. In this work, we investigate an electronic portal imaging device (EPID) based pre-treatment QA method which provides an accurate reconstruction of the 3D-dose distribution in the patient model. Customized patient plans are delivered ‘in air’ and the portal images are collected using the EPID in cine mode. The images are then analysed to determine an estimate of the incident energy fluence. This is then passed to a collapsed-cone convolution dose algorithm which reconstructs a 3D patient dose estimate on the CT imaging dataset. To date, the method has been applied to 5 SBRT patient plans. Reconstructed doses were compared to those calculated by the TPS. Reconstructed mean doses were mostly within 3% of those in the TPS. DVHs of target volumes and OARs compared well. The Chi pass rates using 3%/3mm in the high dose region are greater than 97% in all cases. These initial results demonstrate clinical feasibility and utility of a robust, efficient, effective and convenient pre-treatment QA method using EPID. Research sponsored in part by Varian Medical Systems.

60 APPLIED LIFE SCIENCES↗

Research on reconstruction method for pebble-detecting CT system for PB-HTGR - 186633

In the pebble-bed high temperature gas-cooled reactor (PB-HTGR), pebble dynamics in the reactor is important for safe operation. However, the experimental research at present were mostly implemented in two-dimensional models or limited to phenomenological methods. To investigate pebble dynamics using a three-dimensional experimental method, we designed a platform with a pebble-detecting CT system exactly as the proportion of 1:5 with the actual HTR-PM. Multi-slice helical CT can provide cross-sectional images of fuel pebbles at any place during motion, allowing for pebble trajectories to be obtained during the whole unloading process. The purpose of this paper is to design appropriate algorithms to reconstruct cross-sectional images of pebbles for the system. Two methods applicable to distinct situations were discussed and compared. Based on this, a fast reconstruction method was introduced and proved to be the most suitable solution for the system to get pebble trajectories rapidly. The pebble-detecting principle and the effectiveness of the fast reconstruction method were demonstrated by a verification experiment. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Multiscale finite element modeling of sheet molding compound (SMC) composite structure based on stochastic mesostructure reconstruction

Predicting the mechanical behavior of the chopped carbon fiber Sheet Molding Compound (SMC) due to spatial variations in local material properties is critical for the structural performance analysis but is computationally challenging. Such spatial variations are induced by the material flow in the compression molding process. In this work, a new multiscale SMC modeling framework and the associated computational techniques are developed to provide accurate and efficient predictions of SMC mechanical performance. The proposed multiscale modeling framework contains three modules. First, a stochastic algorithm for 3D chip-packing reconstruction is developed to efficiently generate the SMC mesoscale Representative Volume Element (RVE) model for Finite Element Analysis (FEA). A new fiber orientation tensor recovery function is embedded in the reconstruction algorithm to match reconstructions with the target characteristics of fiber orientation distribution. Second, a metamodeling module is established to improve the computational efficiency by creating the surrogates of mesoscale analyses. Third, the macroscale behaviors are predicted by an efficient multiscale model, in which the spatially varying material properties are obtained based on the local fiber orientation tensors. Our approach is further validated through experiments at both meso- and macro-scales, such as tensile tests assisted by Digital Image Correlation (DIC) and mesostructure imaging.

36 MATERIALS SCIENCE↗

3D and 4D magnetic susceptibility tomography based on complex MR images

Magnetic susceptibility is the physical property for T2*-weighted magnetic resonance imaging (T2*MRI). The invention relates to methods for reconstructing an internal distribution (3D map) of magnetic susceptibility values, .chi. (x,y,z), of an object, from 3D T2*MRI phase images, by using Computed Inverse Magnetic Resonance Imaging (CIMRI) tomography. The CIMRI technique solves the inverse problem of the 3D convolution by executing a 3D Total Variation (TV) regularized iterative convolution scheme, using a split Bregman iteration algorithm. The reconstruction of .chi. (x,y,z) can be designed for low-pass, band-pass, and high-pass features by using a convolution kernel that is modified from the standard dipole kernel. Multiple reconstructions can be implemented in parallel, and averaging the reconstructions can suppress noise. 4D dynamic magnetic susceptibility tomography can be implemented by reconstructing a 3D susceptibility volume from a 3D phase volume by performing 3D CIMRI magnetic susceptibility tomography at each snapshot time.

47 OTHER INSTRUMENTATION↗

Physics-assisted generative adversarial network for X-ray tomography

X-ray tomography is capable of imaging the interior of objects in three dimensions non-invasively, with applications in biomedical imaging, materials science, electronic inspection, and other fields. The reconstruction process can be an ill-conditioned inverse problem, requiring regularization to obtain satisfactory results. Recently, deep learning has been adopted for tomographic reconstruction. Unlike iterative algorithms which require a distribution that is known a priori , deep reconstruction networks can learn a prior distribution through sampling the training distributions. In this work, we develop a Physics-assisted Generative Adversarial Network (PGAN), a two-step algorithm for tomographic reconstruction. In contrast to previous efforts, our PGAN utilizes maximum-likelihood estimates derived from the measurements to regularize the reconstruction with both known physics and the learned prior. Compared with methods with less physics assisting in training, PGAN can reduce the photon requirement with limited projection angles to achieve a given error rate. The advantages of using a physics-assisted learned prior in X-ray tomography may further enable low-photon nanoscale imaging.

47 OTHER INSTRUMENTATION↗

SU-E-I-10: Investigation On Detectability of a Small Target for Different Slice Direction of a Volumetric Cone Beam CT Image

Purpose: To investigate the detectability of a small target for different slice direction of a volumetric cone beam CT image and its impact on dose reduction. Methods: Analytic projection data of a sphere object (1 mm diameter, 0.2/cm attenuation coefficient) were generated and reconstructed by FDK algorithm. In this work, we compared the detectability of the small target from four different backprojection Methods: hanning weighted ramp filter with linear interpolation (RECON 1), hanning weighted ramp filter with Fourier interpolation (RECON2), ramp filter with linear interpolation (RECON 3), and ramp filter with Fourier interpolation (RECON4), respectively. For noise simulation, 200 photons per measurement were used, and the noise only data were reconstructed using FDK algorithm. For each reconstructed volume, axial and coronal slice were extracted and detection-SNR was calculated using channelized Hotelling observer (CHO) with dense difference-of-Gaussian (D-DOG) channels. Results: Detection-SNR of coronal images varies for different backprojection methods, while axial images have a similar detection-SNR. Detection-SNR{sup 2} ratios of coronal and axial images in RECON1 and RECON2 are 1.33 and 1.15, implying that the coronal image has a better detectability than axial image. In other words, using coronal slices for the small target detection can reduce the patient dose about 33% and 15% compared to using axial slices in RECON 1 and RECON 2. Conclusion: In this work, we investigated slice direction dependent detectability of a volumetric cone beam CT image. RECON 1 and RECON 2 produced the highest detection-SNR, with better detectability in coronal slices. These results indicate that it is more beneficial to use coronal slice to improve detectability of a small target in a volumetric cone beam CT image. This research was supported by the MSIP (Ministry of Science, ICT and Future Planning), Korea, under the IT Consilience Creative Program (NIPA-2014-H0201-14-1002) supervised by the NIPA (National IT Industry Promotion Agency). Authors declares that s/he has no conflict of Interest in relation to the work in this abstract.

60 APPLIED LIFE SCIENCES↗