Search NASA⌕ Search

SEARCH · Search NASA

Results for “Regression Analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Oxidation effects on spark plasma sintering of molybdenum nanopowders

Surface-oxidized molybdenum nanopowders are compacted by spark plasma sintering (SPS). The oxide impurity behavior is analyzed under various sintering temperatures. The densification mechanism of the nanopowders with a melted oxide phase is identified in situ by regression analysis of the experimental data on the temperature-dependent porosity change and on the SPS multistep pressure dilatometry. To increase the density of the compacted pellets, the nanopowders with the oxide phase are consolidated by SPS using the two in situ oxide removal methods: carbothermic reduction and particle surface cleaning by the electric current flow through the powders. Finally, the advantages and disadvantages of these methods in terms of the density, grain size, and mechanical properties of the final products are discussed.

36 MATERIALS SCIENCE↗

Modeling of Supercritical CO2 Shell-and-Tube Heat Exchangers Under Extreme Conditions. Part I: Correlation Development

Abstract High-temperature supercritical CO2 Brayton cycles are promising possibilities for future stationary power generation and hybrid electric propulsion applications. Heat exchangers are critical components in supercritical CO2 thermal cycles and require accurate correlations and comprehensive performance modeling under extreme temperatures and pressures. In this paper (Part I), new Colburn and friction factor correlations are developed to quantify shell-side heat transfer and friction characteristics of flow within heat exchangers in the shell-and-tube configuration. Using experimental and computational fluid dynamics (CFD) data sets from existing literature, multivariate regression analysis is conducted to achieve correlations that capture the effect of multiple critical geometric parameters. These correlations offer superior accuracy and versatility as compared to previous studies and predict the thermohydraulic performance of about 90% of the existing experimental and CFD data within ±15%. Supplementary thermohydraulic performance data are acquired from CFD simulations with supercritical CO2 as working fluid to validate the developed correlations and demonstrate its capability to be applied to supercrtical CO2 heat exchangers.

Engineering↗

Comparison of Equivalence Ratio Transients on Combustion Instability in Single-Nozzle and Multi-Nozzle Combustors

Low-emissions gas turbine combustion, achieved through the use of lean, premixed fueling strategies, is susceptible to combustion instability. The driving mechanism for this instability arises from fluctuations of pressure, fuel/air flow rate, and heat release rate. If these fluctuations are relatively in-phase, the combustion system will evolve to a self-excited state. The self-excited instability frequency and amplitude depend mainly on the operating condition and the geometry of the combustor. In this study, we consider the onset and decay of self-excited instabilities, resulting from transients in fuel/air ratio, in both single-nozzle and multi-nozzle combustors. In particular, we examine the differences in the instability onset and decay processes between these two flame configurations, as most gas turbine combustors have multiple nozzles, but most gas turbine combustor experiments utilize a single-nozzle. A nonlinear logistic regression analysis is applied to study the timescales of the decay and onset transients. Variations in the equivalence ratio change the heat release rate distribution inside the combustor, which is captured using chemiluminescence imaging. The normalized Rayleigh index, which shows the spatial distribution of the instability driving, is calculated to analyze the driving strength in different regions of the flame. Comparisons between the single- and multi-nozzle flame transients, including both center and outer flames for the multi-nozzle combustor, suggest that both confinement from the wall and flame-flame interaction are crucial to determining flame dynamics as the equivalence ratio transient changes the heat release rate distribution near corner recirculation zone and flame shear layers.

Chen, Xiaoling↗

TU-F-18A-04: Use of An Image-Based Material-Decomposition Algorithm for Multi-Energy CT to Determine Basis Material Densities

Purpose: Published methods for image-based material decomposition with multi-energy CT images have required the assumption of volume conservation or accurate knowledge of the x-ray spectra and detector response. The purpose of this work was to develop an image-based material-decomposition algorithm that can overcome these limitations. Methods: An image-based material decomposition algorithm was developed that requires only mass conservation (rather than volume conservation). With this method, using multi-energy CT measurements made with n=4 energy bins, the mass density of each basis material and of the mixture can be determined without knowledge of the tube spectra and detector response. A digital phantom containing 12 samples of mixtures from water, calcium, iron, and iodine was used in the simulation (Siemens DRASIM). The calibration was performed by using pure materials at each energy bin. The accuracy of the technique was evaluated in noise-free and noisy data under the assumption of an ideal photon-counting detector. Results: Basis material densities can be estimated accurately by either theoretic calculation or calibration with known pure materials. The calibration approach requires no prior information about the spectra and detector response. Regression analysis of theoretical values versus estimated values results in excellent agreement for both noise-free and noisy data. For the calibration approach, the R-square values are 0.9960+/−0.0025 and 0.9476+/−0.0363 for noise-free and noisy data, respectively. Conclusion: From multi-energy CT images with n=4 energy bins, the developed image-based material decomposition method accurately estimated 4 basis material density (3 without k-edge and 1 with in the range of the simulated energy bins) even without any prior information about spectra and detector response. This method is applicable to mixtures of solutions and dissolvable materials, where volume conservation assumptions do not apply. CHM receives research support from NIH and Siemens Healthcare.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

TU-F-18A-05: An X-Ray Fluorescence Technique for Energy Calibration of Photon-Counting Detectors

Purpose: To investigate the feasibility of energy response calibration of a Si strip photon-counting detector by using the x-ray fluorescence technique. Methods: X-ray fluorescence was generated by using a pencil beam from a tungsten anode x-ray tube with 2 mm Al filtration. Spectra were acquired at 90° from the primary beam direction with an energy-resolved photon-counting detector based on Si strips. The distances from the source to target and the target to detector were approximately 19 and 11 cm, respectively. Four different materials, containing Ag, I, Ba, and Gd, were placed in small plastic aliquots with a diameter of approximately 0.7 cm for x-ray fluorescence measurements. Linear regression analysis was performed to derive the gain and offset values for the correlation between the measured fluorescence peak center and the known energies for materials. The energy resolution was derived from the full width at half maximum (FWHM) of the fluorescence peaks. In addition, the angular dependence of the recorded fluorescence spectra was studied at 30°, 60°, and 120°. Results: Strong fluorescence signals of all four target materials were recorded with the investigated geometry for the Si strip detector. The recorded pulse height was calibrated with respect to photon energy and the gain and offset values were calculated to be 7.0 mV/keV and −69.3 mV, respectively. Negligible variation in energy calibration was observed among the four energy thresholds. The variation among different pixels was estimated to be approximately 1 keV. The energy resolution of the detector was estimated to be 7.9% within the investigated energy range. Conclusion: The performance of a spectral imaging system using energy-resolved photon-counting detectors is very dependent on the energy calibration of the detector. The proposed x-ray fluorescence technique provides an accurate and efficient way to calibrate the energy response of a photon-counting detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of energy response for photon-counting detectors using x-ray fluorescence

Purpose: To investigate the feasibility of characterizing a Si strip photon-counting detector using x-ray fluorescence. Methods: X-ray fluorescence was generated by using a pencil beam from a tungsten anode x-ray tube with 2 mm Al filtration. Spectra were acquired at 90° from the primary beam direction with an energy-resolved photon-counting detector based on an edge illuminated Si strip detector. The distances from the source to target and the target to detector were approximately 19 and 11 cm, respectively. Four different materials, containing silver (Ag), iodine (I), barium (Ba), and gadolinium (Gd), were placed in small plastic containers with a diameter of approximately 0.7 cm for x-ray fluorescence measurements. Linear regression analysis was performed to derive the gain and offset values for the correlation between the measured fluorescence peak center and the known fluorescence energies. The energy resolutions and charge-sharing fractions were also obtained from analytical fittings of the recorded fluorescence spectra. An analytical model, which employed four parameters that can be determined from the fluorescence calibration, was used to estimate the detector response function. Results: Strong fluorescence signals of all four target materials were recorded with the investigated geometry for the Si strip detector. The average gain and offset of all pixels for detector energy calibration were determined to be 6.95 mV/keV and −66.33 mV, respectively. The detector’s energy resolution remained at approximately 2.7 keV for low energies, and increased slightly at 45 keV. The average charge-sharing fraction was estimated to be 36% within the investigated energy range of 20–45 keV. The simulated detector output based on the proposed response function agreed well with the experimental measurement. Conclusions: The performance of a spectral imaging system using energy-resolved photon-counting detectors is very dependent on the energy calibration of the detector. The proposed x-ray fluorescence technique offers an accurate and efficient way to calibrate the energy response of a photon-counting detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Attenuation-based size metric for estimating organ dose to patients undergoing tube current modulated CT exams

Purpose: Task Group 204 introduced effective diameter (ED) as the patient size metric used to correlate size-specific-dose-estimates. However, this size metric fails to account for patient attenuation properties and has been suggested to be replaced by an attenuation-based size metric, water equivalent diameter (D{sub W}). The purpose of this study is to investigate different size metrics, effective diameter, and water equivalent diameter, in combination with regional descriptions of scanner output to establish the most appropriate size metric to be used as a predictor for organ dose in tube current modulated CT exams. Methods: 101 thoracic and 82 abdomen/pelvis scans from clinically indicated CT exams were collected retrospectively from a multidetector row CT (Sensation 64, Siemens Healthcare) with Institutional Review Board approval to generate voxelized patient models. Fully irradiated organs (lung and breasts in thoracic scans and liver, kidneys, and spleen in abdominal scans) were segmented and used as tally regions in Monte Carlo simulations for reporting organ dose. Along with image data, raw projection data were collected to obtain tube current information for simulating tube current modulation scans using Monte Carlo methods. Additionally, previously described patient size metrics [ED, D{sub W}, and approximated water equivalent diameter (D{sub Wa})] were calculated for each patient and reported in three different ways: a single value averaged over the entire scan, a single value averaged over the region of interest, and a single value from a location in the middle of the scan volume. Organ doses were normalized by an appropriate mAs weighted CTDI{sub vol} to reflect regional variation of tube current. Linear regression analysis was used to evaluate the correlations between normalized organ doses and each size metric. Results: For the abdominal organs, the correlations between normalized organ dose and size metric were overall slightly higher for all three differently (global, regional, and middle slice) reported D{sub W} and D{sub Wa} than they were for ED, but the differences were not statistically significant. However, for lung dose, computed correlations using water equivalent diameter calculated in the middle of the image data (D{sub W,middle}) and averaged over the low attenuating region of lung (D{sub W,regional}) were statistically significantly higher than correlations of normalized lung dose with ED. Conclusions: To conclude, effective diameter and water equivalent diameter are very similar in abdominal regions; however, their difference becomes noticeable in lungs. Water equivalent diameter, specifically reported as a regional average and middle of scan volume, was shown to be better predictors of lung dose. Therefore, an attenuation-based size metric (water equivalent diameter) is recommended because it is more robust across different anatomic regions. Additionally, it was observed that the regional size metric reported as a single value averaged over a region of interest and the size metric calculated from a single slice/image chosen from the middle of the scan volume are highly correlated for these specific patient models and scan types.

60 APPLIED LIFE SCIENCES↗

The proton charge radius extracted from the initial-state radiation experiment at MAMI

Abstract We report on a comprehensive reinterpretation of the existing cross-section data for elastic electron-proton scattering obtained by the initial-state radiation technique, resulting in a significantly improved accuracy of the extracted proton charge radius. By refining the external energy corrections we have achieved an outstanding description of the radiative tail, essential for a detailed investigation of the proton finite-size effects on the measured cross sections. This development, together with a novel framework for determining the radius, based on a regression analysis of the cross sections employing a polynomial model for the form factor, led us to a new value for the charge radius, which is $$(0.878 \pm 0.011_\mathrm {stat.}\pm 0.031_\mathrm {sys.}\pm 0.002_\mathrm {mod.})\,\mathrm {fm}$$ ( 0.878 ± 0 . 011 stat . ± 0 . 031 sys . ± 0 . 002 mod . ) fm

Physics↗

An Adaptive Cross-Architecture Combination Method for Graph Traversal

Breadth-First Search (BFS) is widely used in many real-world applications including computational biology, social networks, and electronic design automation. The combination method, using both top-down and bottom-up techniques, is the most effective BFS approach. However, current combination methods rely on trial-and-error and exhaustive search to locate the optimal switching point, which may cause significant runtime overhead. To solve this problem, we design an adaptive method based on regression analysis to predict an optimal switching point for the combination method at runtime within less than 0.1% of the BFS execution time.

You, Yang↗

Composition and Manufacturing Effects on Electrical Conductivity of Li/FeS 2 Thermal Battery Cathodes

The electrical conductivity is key to the performance of thermal battery cathodes. In this work we present the effects of manufacturing and processing conditions on the electrical conductivity of Li/FeS2 thermal battery cathodes. Finite element simulations were used to compute the conductivity of three-dimensional microcomputed tomography cathode microstructures and compare results to experimental impedance spectroscopy measurements. A regression analysis reveals a predictive relationship between composition, processing conditions, and electrical conductivity; a trend which is largely erased after thermally-induced deformation. Moreover, the trend applies to both experimental and simulation results, although is not as apparent in simulations. This research is a step toward a more fundamental understanding of the effects of processing and composition on thermal battery component microstructure, properties, and performance.

25 ENERGY STORAGE↗

Association Between Prevalence of Peripheral Artery Disease and Radiation Exposure in the Atomic Bomb Survivors

Past reports suggested that total-body irradiation at 0.5 to 1.0 Gy could be responsible for atherosclerosis. Peripheral artery disease (PAD) is a manifestation of systematic atherosclerosis. Whether the consequences of a low-to-moderate dose of radiation include increased risk of PAD remains to be determined. The purpose of this study was to examine the association between radiation exposure and prevalence of PAD among Japanese atomic bomb survivors. Radiation exposure from the atomic bombing was assessed in 3476 participants (41.1% men, mean age 74.8 years with SD 6.4 years) with a cross-sectional survey in 2010 to 2014. Left- and right-side ankle-brachial indexes and upstroke time (UT) were obtained using oscillometric VP-2000. PAD was defined as an ankle-brachial index of 1.0 or less or a prior history related to revascularization. UT was considered a sensitive marker of early-stage PAD. Association between radiation exposure and PAD or UT was assessed using multivariable regression analyses with adjustment for potential confounding factors. Of 3476 participants, 79 (2.3%) were identified as having prevalent PAD. Multivariate logistic regression analysis indicated that radiation dose was unrelated to PAD prevalence (odds ratio, 0.83; 95% confidence interval [0.57-1.21]). UT appeared to increase with radiation dose, but the increase was not statistically significant (1.09 ms/Gy; 95% confidence interval [-0.17 to 2.36]). We found no clear association of radiation dose with PAD, but it remains to be determined whether UT is associated with radiation dose.

60 APPLIED LIFE SCIENCES↗

Two-Day Westward-Propagating Inertio-Gravity Waves during GoAmazon

The dynamical and thermodynamical features of Amazonian 2-day westward-propagating inertia–gravity (WIG) waves are examined. On the basis of a linear regression analysis of satellite brightness temperature and data from the 2014–15 Observations and Modeling of the Green Ocean Amazon (GoAmazon) field campaign, it is shown that Amazonian WIG waves exhibit structure and propagation characteristics consistent with the n = 1 WIG waves from shallow water theory. These WIG waves exhibit a pronounced seasonality, with peak activity occurring from March to May and a minimum occurring from June to September. Evidence is shown that mesoscale convective systems over the Amazon are frequently organized in 2-day WIG waves. Results suggest that many of the Amazonian WIG waves come from preexisting 2-day waves over the Atlantic, which slow down when coupled with the deeper, more intense convection over tropical South America. In contrast to WIG waves that occur over the ocean, Amazonian 2-day WIG waves exhibit a pronounced signature in surface temperature, moisture, and heat fluxes.

54 ENVIRONMENTAL SCIENCES↗

Biogeophysical Effects of Land-Use and Land-Cover Change Not Detectable in Warmest Month

Land-use and land-cover changes (hereafter simply “land use”) alter climates biogeophysically by affecting surface fluxes of energy and water. Yet, near-surface temperature responses to land use across observational versus model-based studies and spatial-temporal scales can be inconsistent. Here we assess the prevalence of the historical land use signal of daily maximum temperatures averaged over the warmest month of the year (t LU ) using regularized optimal fingerprinting for detection and attribution. We use observations from the Climatic Research Unit and Berkeley Earth alongside historical simulations with and without land use from phase 6 of the Coupled Model Intercomparison Project to reconstruct an experiment representing the effects of land use on climate. To assess the signal of land use at spatially resolved continental and global scales, we aggregate all input data across reference regions and continents, respectively. At both scales, land use does not comprise a significantly detectable set of forcings for two of four Earth system models and their multimodel mean. Furthermore, using a principal component analysis, we find that t LU is mostly composed of the nonlocal effects of land use rather than its local effects. These findings show that, at scales relevant for climate attribution, uncertainties in Earth system model representations of land use are too high relative to the effects of internal variability to confidently assess land use.

54 ENVIRONMENTAL SCIENCES↗

Differential patterns of reproductive and lifestyle risk factors for breast cancer according to birth cohorts among women in China, Japan and Korea

Background: The birth cohort effect has been suggested to influence the rate of breast cancer incidence and the trends of associated reproductive and lifestyle factors. We conducted a cohort study to determine whether a differential pattern of associations exists between certain factors and breast cancer risk based on birth cohorts. Methods: This was a cohort study using pooled data from 12 cohort studies. We analysed associations between reproductive (menarche age, menopause age, parity and age at first delivery) and lifestyle (smoking and alcohol consumption) factors and breast cancer risk. We obtained hazard ratios (HRs) with 95% confidence intervals (CIs) using the Cox proportional hazard regression analysis on the 1920s, 1930s, 1940s and 1950s birth cohorts. Results: Parity was found to lower the risk of breast cancer in the older but not in the younger birth cohort, whereas lifestyle factors showed associations with breast cancer risk only among the participants born in the 1950s. In the younger birth cohort group, the effect size was lower for parous women compared to the other cohort groups (HR [95% CI] 0.86 [0.66–1.13] compared to 0.60 [0.49–0.73], 0.46 [0.38–0.56] and 0.62 [0.51–0.77]). Meanwhile, a higher effect size was found for smoking (1.45 [1.14–1.84] compared to 1.25 [0.99–1.58], 1.06 [0.85–1.32] and 0.86 [0.69–1.08]) and alcohol consumption (1.22 [1.01–1.48] compared to 1.10 [0.90–1.33], 1.15 [0.96–1.38], and 1.07 [0.91–1.26]). Conclusion: We observed different associations of parity, smoking and alcohol consumption with breast cancer risk across various birth cohorts.

60 APPLIED LIFE SCIENCES↗

Evaluation of an open forecasting challenge to assess skill of West Nile virus neuroinvasive disease prediction

Abstract Background West Nile virus (WNV) is the leading cause of mosquito-borne illness in the continental USA. WNV occurrence has high spatiotemporal variation, and current approaches to targeted control of the virus are limited, making forecasting a public health priority. However, little research has been done to compare strengths and weaknesses of WNV disease forecasting approaches on the national scale. We used forecasts submitted to the 2020 WNV Forecasting Challenge, an open challenge organized by the Centers for Disease Control and Prevention, to assess the status of WNV neuroinvasive disease (WNND) prediction and identify avenues for improvement. Methods We performed a multi-model comparative assessment of probabilistic forecasts submitted by 15 teams for annual WNND cases in US counties for 2020 and assessed forecast accuracy, calibration, and discriminatory power. In the evaluation, we included forecasts produced by comparison models of varying complexity as benchmarks of forecast performance. We also used regression analysis to identify modeling approaches and contextual factors that were associated with forecast skill. Results Simple models based on historical WNND cases generally scored better than more complex models and combined higher discriminatory power with better calibration of uncertainty. Forecast skill improved across updated forecast submissions submitted during the 2020 season. Among models using additional data, inclusion of climate or human demographic data was associated with higher skill, while inclusion of mosquito or land use data was associated with lower skill. We also identified population size, extreme minimum winter temperature, and interannual variation in WNND cases as county-level characteristics associated with variation in forecast skill. Conclusions Historical WNND cases were strong predictors of future cases with minimal increase in skill achieved by models that included other factors. Although opportunities might exist to specifically improve predictions for areas with large populations and low or high winter temperatures, areas with high case-count variability are intrinsically more difficult to predict. Also, the prediction of outbreaks, which are outliers relative to typical case numbers, remains difficult. Further improvements to prediction could be obtained with improved calibration of forecast uncertainty and access to real-time data streams (e.g. current weather and preliminary human cases). Graphical Abstract

54 ENVIRONMENTAL SCIENCES↗

A numerical study of surface-wave-based tunnel detection at the Black Diamond Mines Regional Preserve, California

Detecting underground voids, such as old mine workings, solution cavities in karst terrain, or unknown tunnels such as illicit cross-border tunnels, is a challenging problem for geophysics and an important concern for geotechnical design, public safety, and domestic security. Seismic surface-wave-based detection methods have become increasingly popular for detecting relatively shallow and small targets; however, the theoretical limitations of these methods have thus far remained unclear. We use a suite of 3D numerical simulations inspired by a tunnel detection experiment carried out at the Black Diamond Mines Regional Preserve (BDM) in northern California. The geophysical anomalies predicted by our numerical simulations at BDM agree with field observations, and our estimates for the location of the primary tunnel target agree with historical records in the area. Using our calibrated numerical model, we perform a parametric study to determine the effect of tunnel size, depth of burial, filling material, and source characteristics to determine the range over which surface-wave backscattering and attenuation-based methods are effective. Additionally, we perform a regression analysis to determine a relationship for the maximum depth at which a tunnel may be detected via these approaches, given the target diameter, wavelength of interest, and the signal-to-noise ratio.

58 GEOSCIENCES↗

Internal Mammary Chain Sentinel Nodes in Early-Stage Breast Cancer Patients: Toward Selective Removal

Background: Removal of internal mammary chain sentinel nodes (IMCSNs) affects prognosis and treatment of breast cancer, and internal mammary chain radiotherapy (IMCRT) can improve survival for selected patients. This study aimed to determine the effect of IMCSN biopsy on recurrence-free survival (RFS) and overall survival (OS) and to identify predictive factors for IMCSN and distant metastasis. Methods: Patients with IMCSNs were selected from a prospective database for the period 1999–2007. Lymphoscintigraphy was performed after intratumoral technetium-99 m injection, and all sentinel nodes were removed. Both RFS and OS were calculated for subgroups with tumor-positive, tumor-negative, or non-removed IMCSNs. Predictive factors were identified for tumor-positive IMCSNs and distant metastasis by regression analysis. Results: For 287 (85%) of 336 patients, IMCSN biopsy was performed, and metastasis was detected in 38 patients (13%). The patients with tumor-positive IMCSNs had poorer OS than the patients with no IMCSN metastasis or non-removed IMCSNs (p = 0.002). These patients also had worse RFS due to distant metastasis (p = 0.002). Axillary metastasis was predictive for tumor-positive IMCSNs (positive predictive value, 38.5%). The predictive factors for distant metastasis were tumor-positive IMCSNs (hazard ratio [HR], 2.5), non-removed IMCSNs (HR, 2.3), tumor diameter greater than 1.5 cm (HR, 3.5), and age older than 65 years (HR, 3.1; reference, < 50 years). Conclusions: Patients with IMCSNs have worse survival due to distant metastasis. The clinically relevant predictive factor for distant metastasis is tumor larger than 1.5 cm. According to the authors’ current protocol, IMCSN biopsy is performed for patients younger than 70 years who have a tumor larger than 1.5 cm, with the cardiotoxicity of the adjuvant IMCRT weighed against the survival benefit.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Tumor Volume Is Better Than Diameter for Predicting the Prognosis of Patients with Early-Stage Non-small Cell Lung Cancer

Background: This study aimed to investigate whether tumor volume (TV) is better than diameter for predicting the prognosis of patients with early-stage non-small cell lung cancer (NSCLC) after complete resection. Methods: This study retrospectively reviewed the clinicopathologic characteristics of 274 patients with early-stage NSCLC who had received pretreatment computed tomography (CT) scans and complete resection. TV was semi-automatically measured from CT scans using an imaging software program. The optimal cutoff of TV was determined by X-tile software. Disease-free survival (DFS) and overall survival (OS) were assessed by the Kaplan–Meier method. The prognostic significance of TV and other variables was assessed by Cox proportional hazards regression analysis. Results: Using 3.046 cm{sup 3} and 8.078 cm{sup 3} as optimal cutoff values of TV, the patients were separated into three groups. A larger TV was significantly associated with poor DFS and OS in the multivariable analysis. Kaplan–Meier curves of DFS and OS showed significant differences on the basis of TV among patients with stage 1a disease, greatest tumor diameter (GTD) of 2 cm or smaller, and GTD of 2–3 cm, respectively. Using two TV cutoff points, three categories of TV were created. In 54 cases (19.7%), patients migrated from the GTD categories of 2 cm or smaller, 2–3 cm, and larger than 3 cm into the TV categories of 3.046 cm{sup 3} or smaller, 3.046–8.078 cm{sup 3}, and larger than 8.078 cm{sup 3}. Conclusion: TV is an independent prognostic factor of DFS and OS for early-stage NSCLC. The findings show that TV is better than GTD for predicting the prognosis of patients with early-stage NSCLC.

62 RADIOLOGY AND NUCLEAR MEDICINE↗