At least 757 records · Page 42

Backup power or bill savings? How electricity tariffs impact residential solar-plus-storage usage in the United States

Adoption of paired solar-plus-storage systems has accelerated in recent years, driven by both the demand for backup power and a desire to manage utility bills. Tradeoffs between those two uses can arise through the reserve setting on the battery storage system, which serves to maintain a minimum state of charge in case of a power interruption. Our paper applies an economic framework to evaluate this tradeoff in terms of changes in bill savings and customer reliability value across reserve levels, considering how those tradeoffs depend on the underlying electricity rate structure and levels. The analysis is based on a representative set of load profiles, solar profiles, tariff designs, and stochastic power interruption events across ten different regions in the United States. We find that the opportunity cost of holding storage capacity in reserve, in terms of foregone bill reductions, outweighs any gains in reliability value from mitigated power interruptions in the majority of customer situations. Higher storage reserve levels increase total customer value only in specific circumstances, such as for customers with inferior reliability (10x average interruptions), with a very high value of lost load ($50/kWh), and with tariff or interconnection rules that disallow grid charging. However, even this result is dampened when considering tariff designs with higher price differentials that increase the opportunity cost of holding storage in reserve (e.g. import/export or time-of-use rates). Allowing grid charging in tariffs essentially eliminates the necessity to hold any storage in reserve in all sensitivity cases explored.

Electric resilience↗

Coordinated Wind Power Plant and Battery Control for Active Power Services

This article considers joint active power control of wind turbines and battery storage to follow a plant-level power reference signal. The joint control dynamically curtails the energy from a subset of the wind turbines and stores or withdraws energy from the battery to meet the power reference setpoint while accounting for wind plant aerodynamic interactions, such as wake losses. As a use case, we study the performance of the controller in maintaining a constant power output over hourly periods. A wind plant operating in this way would rely much less on other grid resources to meet its contractual agreements, thereby improving grid reliability, especially in grids with high penetration of wind and solar generation. We compare the operation of the wind plant under joint active power control to standard power-maximizing control with battery support. We present an analysis of the performance of the control system architecture. To study the impact of the battery size on performance, we simulate a 50-MW wind plant supported by batteries ranging from 8 to 64?MWh. We then evaluate the over and undergeneration penalties incurred by the plant during the simulation period.

17 WIND ENERGY↗

Multi-scale planning model for robust urban drought response

Increasingly severe droughts are straining municipal water resources and jeopardizing urban water security, but uncertainty in their duration, frequency, and intensity challenges drought planning and response. We develop the Drought Resilient Interscale Portfolio Planning model (DRIPP) to generate optimal planning responses to urban drought. DRIPP is a generalizable multi-scale framework for optimizing dynamic planning strategies of long-term infrastructure deployment and short-term drought response. It integrates climate and hydrological variability with high-fidelity representations of urban water distribution, available technology options, and demand reduction measures to yield robust and cost-effective water supply portfolios that are location-specific. We apply DRIPP in Santa Barbara, California to assess how least cost water supply portfolios vary under different drought scenarios and identify portfolios that are robust across drought scenarios. In Santa Barbara, we find that drought intensity, not duration or frequency, drives cost increases, reliability risk, and regret of overbuilding infrastructure. Under uncertain drought conditions, a diversified technology portfolio that includes both rapidly deployable, decentralized technologies alongside larger centralized technologies minimizes water supply cost while maintaining high robustness to climate uncertainty.

54 ENVIRONMENTAL SCIENCES↗

Understanding and Estimating Error Propagation in Neural Networks for Scientific Data Analysis

Neural networks are increasingly integrated into scientific discovery, where input data reduction and model quantization play a key role in accelerating inference. However, understanding and mitigating the impact of these techniques on output error is critical for ensuring reliable results, particularly in tasks demanding high numerical precision. This paper introduces a comprehensive framework for optimizing neural network inference in scientific computing by combining data reduction and weight quantization while maintaining error-controlled outcomes. We develop theoretical analyses to bound error propagation under these reductions and propose a framework that balances computational performance with error constraints. Evaluation on real-world learning-based combustion simulations and satellite image classification demonstrates that our derived error bounds accurately predict observed errors while enabling significant computational speedup under our framework. This work highlights the potential for further leveraging advancements in modern lossy compression algorithms and hardware accelerators that support lower-precision formats.

He, Weiming [New Jersey Institute of Technology]↗

Dynamic Power Distribution System Management With a Locally Connected Communication Network

Coordinated optimization and control of distribution-level assets can enable a reliable and optimal integration of massive amount of distributed energy resources (DERs) and facilitate distribution system management (DSM). Accordingly, the objective is to coordinate the power injection at the DERs to maintain certain quantities across the network, e.g., voltage magnitude, line flows, or line losses, to be close to a desired profile. By and large, the performance of the DSM algorithms has been challenged by two factors: i) the possibly non-strongly connected communication network over DERs that hinders the coordination; ii) the dynamics of the real system caused by the DERs with heterogeneous capabilities, time-varying operating conditions, and real-time measurement mismatches. In this paper, we investigate the modeling and algorithm design and analysis with the consideration of these two factors. In particular, a game theoretic characterization is first proposed to account for a locally connected communication network over DERs, along with the analysis of the existence and uniqueness of the Nash equilibrium (NE) therein. To achieve the equilibrium in a distributed fashion, a projected-gradient-based asynchronous DSM algorithm is then advocated. The algorithm performance, including the convergence speed and the tracking error, is analytically guaranteed under the dynamic setting. In conclusion, extensive numerical tests on both synthetic and realistic cases corroborate the analytical results derived.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Grid-Scale Electricity Storage at Lowest Possible Cost Enabled by Pumped Heat Electricity Storage (Final Report)

Grid-scale energy storage technologies that can provide greater than 10 hours of electricity at full power address a critical need for full penetration of renewables on electricity grids worldwide, minimize renewable curtailment, and maximize grid security and reliability. Pumped Heat Energy Storage (PHES) systems can store energy thermally in any location at the low costs necessary for displacing fossil fuels, reducing foreign fuel imports, and reducing emissions to maintain the energy security of the United States. The award allowed Southwest Research Institute® (SwRI®) and Malta, Inc. (Malta) to advance the PHES concept to a proof-of-concept demonstration for a kW-scale system. The project focused on system operation and integration. The main project objectives were: 1. Address first implementation challenges 2. Explore system control strategies and operation 3. Translate lessons learned to the full-scale system Through these objectives the project completes a first demonstration of this technology and reduces the technical risk associated with a full-scale system.

25 ENERGY STORAGE↗

Nailing the Peak: City-Scale, Building-Specific Load Factor and Contribution to a Utility’s Hour of Critical Generation

Maintaining electrical generation assets to meet peak demand increases the cost of providing electricity to a country’s buildings and insufficient assets can result in power outages. In order to keep reliable electricity costs low for consumers and demand charges low for utilities, there exist markets and financial incentives for limiting consumption during peak demand.The team has partnered with an electrical distributor servicing a 1,390 km2 area and 178,368 buildings with the aim of using urban-scale building energy modelling to inform business decisions necessary for the operation of their electric grid. A suite of software has been developed that allows the scalable creation of a “digital twin” for all buildings in the utility’s service area. This virtual utility area is analysed for targeted deployment of new technologies or policies to assess building-specific savings, effects on critically-loaded grid infrastructure (e.g. feeders, substations), and aggregated impact to utility-scale operations.This work leverages 15-minute data from each building to compare actual and simulated monthly peak-hour demand and assessment of the load factor for each building. Findings include market characterization via clustering of relative energy use profiles for ~180,000 buildings as well as simulation-informed savings opportunities indicating residential load factors of 0.17, commercial load factors of 0.2-0.4 depending on year of construction, and general load factors of 0.16-0.5 depending on building type.

New, Joshua↗

Nanoporous Gold as a Neural Interface Coating: Effects of Topography, Surface Chemistry, and Feature Size

We report that designing neural interfaces that maintain close physical coupling of neurons to an electrode surface remains a major challenge for both implantable and in vitro neural recording electrode arrays. Typically, low-impedance nanostructured electrode coatings rely on chemical cues from pharmaceuticals or surface-immobilized peptides to suppress glial scar tissue formation over the electrode surface (astrogliosis), which is an obstacle to reliable neuron–electrode coupling. Nanoporous gold (np-Au), produced by an alloy corrosion process, is a promising candidate to reduce astrogliosis solely through topography by taking advantage of its tunable length scale. In the present in vitro study on np-Au’s interaction with cortical neuron–glia co-cultures, we demonstrate that the nanostructure of np-Au achieves close physical coupling of neurons by maintaining a high neuron-to-astrocyte surface coverage ratio. Atomic layer deposition-based surface modification was employed to decouple the effect of morphology from surface chemistry. Additionally, length scale effects were systematically studied by controlling the characteristic feature size of np-Au through variations in the dealloying conditions. In conclusion, our results show that np-Au nanotopography, not surface chemistry, reduces astrocyte surface coverage while maintaining high neuronal coverage and may enhance neuron–electrode coupling through nanostructure-mediated suppression of scar tissue formation.

36 MATERIALS SCIENCE↗

Reliability of emergency and standby diesel generators: Impact on energy resiliency solutions

Emergency diesel generators are the most common form of backup power for critical loads when the grid fails and are most often deployed as stand-alone generators (<2000 kW) tied to individual buildings for hospitals, emergency services, military bases, ports, airports, industries, and commercial facilities. Understanding the finite reliability of emergency diesel generators during continuous operation is critical for energy planners, managers, and end-users. A new analysis of two large non-public emergency diesel generator operational data sets shows that commonly used reliability metrics are inadequate to predict the performance during a grid outage. Additional metrics addressing the likelihood of an emergency diesel generator to be available at the time an outage starts, successfully start and carry load, and constantly run for the duration of the outage are needed to predict the continuous run-time reliability of emergency diesel generators during a grid outage. This is the first analysis of the reliability of modern generators that follow standard maintenance protocols commonly used for backup power and these new metrics are shown to be dependent on the level of emergency diesel generator maintenance with values that can vary by more than an order of magnitude. Even using the new metrics for well-maintained emergency diesel generators, the analysis shows that the single emergency diesel generators configurations are only 80% likely to provide power for the duration of a two-week grid outage.

ENERGY PLANNING, POLICY, AND ECONOMY,POWER TRANSMI↗

Understanding and mitigating process drift in aerosol jet printing

Aerosol jet printing offers a versatile, high-resolution prototyping capability for flexible and hybrid electronics. Despite its rapid growth in recent years, persistent problems such as process drift hinder the adoption of this technology in production environments. Here we explore underlying causes of process drift during aerosol jet printing and introduce an engineered solution to improve deposition stability. In this work it is shown that the ink level within the cartridge is a critical factor in determining atomization efficiency, such that the reduction in ink volume resulting from printing itself can induce significant and systematic process drift. By integrating a custom 3D-printed cartridge with an ink recirculation system, ink composition and level within the cartridge are better maintained. This strategy allows extended duration printing with improved stability, as evidenced by 30 h of printing over 5 production runs. This provides an important tool for extending the duration and improving reliability for aerosol jet printing, a key factor for integration in practical manufacturing operations.

36 MATERIALS SCIENCE↗

Using Smart Grids to Enhance Use of Energy-Efficiency and Renewable-Energy Technologies

This report addresses the Asia-Pacific Economic Cooperation (APEC) organization’s desire to minimize the learning time required to understand the implications of smart-grid concepts so APEC members can advance their thinking in a timely manner and advance strategies regarding smart approaches that can help meet their environmental-sustainability and energy-efficiency policy goals. As significant investments are needed to grow and maintain the electricity infrastructure, consideration needs to be given to how information and communications technologies can be applied to electricity infrastructure decisions that not only meet traditional needs for basic service and reliability, but also provide the flexibility for a changing the mix of generation sources with sensitivity to environmental and societal impacts.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Advanced Solar and Load Forecasting Incorporating HD Sky Imaging: BNL Phase II Activities (Final Report)

Over the last ten years, lower costs and government incentives for rooftop and utility scale solar photovoltaic (PV) systems have led to a rapid growth in the amount of power generated from this renewable energy source. For example, the cumulative PV generating capacity of 1,160 MW in New York State at the end of 2018 represents a growth of more than 4,000% over the past seven years and almost 400% over the past five years. But increased dependence on this inherently variable energy source introduces the need to anticipate, i.e., forecast, changes in energy production and manage them appropriately. Utilities and grid operators can then use this forecast information to balance changes and maintain stability of the electric grid by adding additional sources or diverting excess supplies for sale or storage, as needed. Current techniques based on persistence modeling are not accurate enough to provide reliable forecasts. With support from the U.S. Department of Energy’s Solar Energy Technology Office (DOE SETO) and the New York Power Authority (NYPA), Brookhaven National Laboratory (BNL), the National Center for Atmospheric Research (NCAR), and the Electric Power Research Institute (EPRI) formed a collaborative team to provide reliable forecasting over a range of time intervals. In addition, the forecasting area was scaled up to about 50 km2, a factor of 20 times larger than previously achieved, so that available solar irradiance could be forecast throughout an entire region including both large generating facilities and distributed rooftop solar arrays. In its role, BNL developed a technology for predicting changes in available solar energy from zero to 30 minutes ahead. This “nowcasting” approach uses inexpensive, off-the-shelf, high definition (HD) imagers with custom software to identify and track the movement of approaching clouds and predict their impact on available solar irradiance. The BNL Nowcasting model improves forecasting accuracy by 20 to 50% over current techniques. Forecasting reliability for low clouds (worst case scenario since they move over solar panels more rapidly than high clouds) was calculated to be 95% accurate for forecast periods of five minute ahead. Reliability decreases with longer forecast time intervals and was calculated to be about 80% for 10 minute forecasts, and about 70% for 20 minutes ahead. Clouds were still reliably tracked by the imager network at 60% accuracy for forecast lead times up to about 30 minutes ahead, and this was determined to be the practical nowcasting limit for low clouds in a network of this scale. This work represents the second phase of a multi-phase effort to develop and deploy solar forecasting at a regional scale so that contributions from distributed rooftop solar resources can be forecast along with solar generating facilities, giving utilities and stakeholders an accurate assessment of future energy production. Additional work is planned to operate the forecasting network in an area upstate New York to assess system reliability under diverse meteorological conditions and to monitor system performance over a full range of seasonal variability.

14 SOLAR ENERGY↗

R&D to Ensure a Scientific Basis for Qualification Tests and Standards (Final Report: FY19-FY22)

This is the final technical report for the FY19-FY21 research program "R&D to Ensure a Scientific Basis for Qualification Tests and Standards." This research was performed because project return on investment in a photovoltaic (PV) system depends increasingly on maintaining high energy yields, and the system lifetime is a major factor in levelized cost of electricity (LCOE). Thus, the rate of PV deployment and the success of these assets depends upon reliable long-term power generation. This program advances PV module reliability of commercial products through identification of reliability needs, characterization that provides scientific understanding of targeted degradation mechanisms, and translation of those data into practical and predictive test protocols and standards. This report describes program scope, results, milestones, and accomplishments over the three-year period of performance.

14 SOLAR ENERGY↗

R&D to Ensure a Scientific Basis for Qualification Tests and Standards (Final Report)

Project return on investment in a photovoltaic (PV) system depends increasingly on maintaining high energy yields, and the system lifetime is a major factor in levelized cost of electricity (LCOE). Thus, the rate of PV deployment and the success of these assets depends upon reliable long-term power generation. The overarching objective of this program is to improve photovoltaic (PV) module reliability via development of tests and standards. Where reliability problems or risk are discovered, we can design tests to ensure that these liabilities don't affect future generations of products. Customers can use these tests to understand which products are susceptible to certain degradation mechanisms, and manufacturers can use the tests to design unwanted characteristics out of their products. The work under this program identifies PV reliability needs, performs characterization that provides scientific understanding of targeted degradation mechanisms, and translates those data into practical and predictive test protocols and standards. Major accomplishments include: A model for polarization-type potential induced degradation (PID-p) was developed and validated against experimental data. NREL is currently leading a new edition of IEC 62804-1 for PID detection. PID-p can cause large losses in current and voltage for some module designs on cloudy days. Finite element modeling (FEM) and experiment was used to determine when cells crack in a module. It was shown that cells in landscape orientation are much more likely to crack than those on portrait orientation. Shortly thereafter, the first products with portrait-oriented cells were introduced. Studies of how to test for light and elevated temperature degradation (LeTID) culminated with the publication of IEC TS 63342. Software to predict the progression of LeTID was developed, validated, and made publicly available. Field validated tests and international standards for durability of PV module coatings abrasion, backsheets, and encapsulants were developed. Examples are IEC 62788-1-1, IEC 62788-2 ED2, IEC TS 62788-7-2, IEC 62788-7-3 ED1, IEC 63209-2. NREL led the development a high-temperature testing technical specification, and published guidelines that enable installers to determine whether higher-temperature testing is needed, simply based on location and mounting configuration. In a number of our case studies, variations in the bills of materials or workmanship have been associated with variations in reliability. These observations emphasize the importance of quality assurance to reliability. A framework for criticality (i.e. Pareto) analysis was developed and published. The framework helps us and other researchers determine what problems should be addressed for reliability research to have the biggest industry impact. NREL continues to participate actively in international standards development and stakeholder engagement activities, including organizing an annual PV Reliability Workshop. These activities are important for ensuring we address issues that are relevant and timely, and that we convey our results to those who may benefit.

14 SOLAR ENERGY↗

Five Kilowatt Fuel Cell Demonstration for Remote Power Applications

While most areas of the US are serviced by inexpensive, dependable grid connected electrical power, many areas of Alaska are not. In these areas, electrical power is provided with Diesel Electric Generators (DEGs), at much higher cost than in grid connected areas. The reasons for the high cost of power are many, including the high relative cost of diesel fuel delivered to the villages, the high operational effort required to maintain DEGs, and the reverse benefits of scale for small utilities. Recent progress in fuel cell technologies have lead to the hope that the DEGs could be replaced with a more efficient, reliable, environmentally friendly source of power in the form of fuel cells. To this end, the University of Alaska Fairbanks has been engaged in testing early fuel cell systems since 1998. Early tests were conducted on PEM fuel cells, but since 2001, the focus has been on Solid Oxide Fuel Cells. In this work, a 5 kW fuel cell was delivered to UAF from Fuel Cell Technologies of Kingston, Ontario. The cell stack is of a tubular design, and was built by Siemens Westinghouse Fuel Cell division. This stack achieved a run of more than 1 year while delivering grid quality electricity from natural gas with virtually no degradation and at an electrical efficiency of nearly 40%. The project was ended after two control system failures resulted in system damage. While this demonstration was successful, considerable additional product development is required before this technology is able to provide electrical energy in remote Alaska. The major issue is cost, and the largest component of system cost currently is the fuel cell stack cost, although the cost of the balance of plant is not insignificant. While several manufactures are working on schemes for significant cost reduction, these systems do not as yet provide the same level of performance and reliability as the larger scale Siemens systems, or levels that would justify commercial deployment.

03 NATURAL GAS↗

Evaluation of Horizon of Viability Optimization Engine for Sustained Power to Critical Infrastructure: Preprint

In the aftermath of increasingly frequent catastrophic events, a typical scenario is Critical Infrastructure (CI) units being supported by available backup sources with a weak power grid that can be intermittent or absent. Such a scenario is significantly challenging in the sense of reliable supply of power to CI units. In this article, an intelligent optimization scheme termed as Horizon of Viability (HoV) engine is developed to guarantee the viability of a sustained reliable supply of power to the CI units over a time-horizon. The proposed HoV engine generates a cost-optimal portfolio of the locally available generation sources and the loads over a time horizon using a mixed-integer convex programming problem. A Controller hardware-in-the-loop (CHIL) platform is developed to evaluate the control performance of the HoV engine. The experimental results corroborates the efficacy in maintaining the viability of the CI units after a grid interruption event. Further, the proposed HoV optimization scheme performs better compared to existing net-load management schemes in the literature.

disaster resiliency↗

Reducing radiation dose to the female breast during CT coronary angiography: A simulation study comparing breast shielding, angular tube current modulation, reduced kV, and partial angle protocols using an unknown-location signal-detectability metric

Purpose: The authors compared the performance of five protocols intended to reduce dose to the breast during computed tomography (CT) coronary angiography scans using a model observer unknown-location signal-detectability metric.Methods: The authors simulated CT images of an anthropomorphic female thorax phantom for a 120 kV reference protocol and five “dose reduction” protocols intended to reduce dose to the breast: 120 kV partial angle (posteriorly centered), 120 kV tube-current modulated (TCM), 120 kV with shielded breasts, 80 kV, and 80 kV partial angle (posteriorly centered). Two image quality tasks were investigated: the detection and localization of 4-mm, 3.25 mg/ml and 1-mm, 6.0 mg/ml iodine contrast signals randomly located in the heart region. For each protocol, the authors plotted the signal detectability, as quantified by the area under the exponentially transformed free response characteristic curve estimator (A-caret{sub FE}), as well as noise and contrast-to-noise ratio (CNR) versus breast and lung dose. In addition, the authors quantified each protocol's dose performance as the percent difference in dose relative to the reference protocol achieved while maintaining equivalent A-caret{sub FE}.Results: For the 4-mm signal-size task, the 80 kV full scan and 80 kV partial angle protocols decreased dose to the breast (80.5% and 85.3%, respectively) and lung (80.5% and 76.7%, respectively) with A-caret{sub FE} = 0.96, but also resulted in an approximate three-fold increase in image noise. The 120 kV partial protocol reduced dose to the breast (17.6%) at the expense of increased lung dose (25.3%). The TCM algorithm decreased dose to the breast (6.0%) and lung (10.4%). Breast shielding increased breast dose (67.8%) and lung dose (103.4%). The 80 kV and 80 kV partial protocols demonstrated greater dose reductions for the 4-mm task than for the 1-mm task, and the shielded protocol showed a larger increase in dose for the 4-mm task than for the 1-mm task. In general, the CNR curves indicate a similar relative ranking of protocol performance as the corresponding A-caret{sub FE} curves, however, the CNR metric overestimated the performance of the shielded protocol for both tasks, leading to corresponding underestimates in the relative dose increases compared to those obtained when using the A-caret{sub FE} metric.Conclusions: The 80 kV and 80 kV partial angle protocols demonstrated the greatest reduction to breast and lung dose, however, the subsequent increase in image noise may be deemed clinically unacceptable. Tube output for these protocols can be adjusted to achieve a more desirable noise level with lesser breast dose savings. Breast shielding increased breast and lung dose when maintaining equivalent A-caret{sub FE}. The results demonstrated that comparisons of dose performance depend on both the image quality metric and the specific task, and that CNR may not be a reliable metric of signal detectability.

61 RADIATION PROTECTION AND DOSIMETRY↗

Coordination and Control of Building HVAC Systems to Provide Frequency Regulation to the Electric Grid

Buildings consume 73% of electricity produced in the United States and, currently, they are largely passive participants in the electric grid. However, the flexibility in building loads can be exploited to provide ancillary services to enhance the grid reliability. In this paper, we investigate two control strategies that allow Heating, Ventilation and Air-Conditioning (HVAC) systems in commercial and residential buildings to provide frequency regulation services to the grid while maintaining occupants comfort. The first optimal control strategy is based on model predictive control acting on a variable air volume HVAC system (continuously variable HVAC load), which is available in large commercial buildings. The second strategy is rule-based control acting on an aggregate of on/off HVAC systems, which are available in residential buildings in addition to many small to medium size commercial buildings. Hardware constraints that include limiting the switching between the different states for on/off HVAC units to maintain their lifetimes are considered. Furthermore, simulations illustrate that the proposed control strategies provide frequency regulation to the grid, without affecting the indoor climate significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗