Economic Sizing of Batteries for the Smart Home
This webinar on the economic sizing of batteries for smart, connected homes was presented on December 14, 2017.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
This webinar on the economic sizing of batteries for smart, connected homes was presented on December 14, 2017.
This presentation provides a high-level overview of integrating more solar with smart inverters.
Presentation offers an overview of energy-efficient Smart Labs, including the benefits, the program, and what it takes to develop one.
A multilevel, multitasking smart grid-enabled conservation of voltage reduction (CVR) control and optimization methodology is proposed for advanced distribution management system (ADMS) platforms. The first level deals with the centralized optimization of volt/VAR optimization (VVO) devices; the second-level is for voltage control in the local domain or decentralized control; and the third level assesses the energy savings and CVR factor.
Heat transfer through windows accounts for a significant percentage of a building’s energy use and adds substantially to the peak cooling load of a home. Window attachment manufacturers currently offer motorized shading devices for certain product lines, but this automation is typically marketed as a convenience and security feature for the homeowner and often does not include energy optimized control algorithms or dynamic and responsive features. This paper describes the experimental results of testing the energy performance of high-efficiency, dynamically operated, cellular shades in Pacific Northwest National Laboratory’s (PNNL) Lab Homes. The results of both heating and cooling season experiments will be presented, where testing is designed to assess the whole home energy savings resulting from both the thermal insulating properties as well as the automated and dynamic control strategies of shading devices. Control schemes tested include common “connected home” strategies where controls are integrated and coordinated between the window shading device, building thermostats, and external sensors. The presentation will also include results from testing designed to examine the benefits (in terms of comfort, energy savings, and responsiveness) of coordinating the operation of cellular shades with HVAC as a demand-response measure. These experiments demonstrate that highly insulating, dynamic window coverings that are reliably controlled can dramatically reduce the heating and cooling energy associated with windows and should be considered an important component of any “smart” home design.
Recently, there is increasing interest in using behind-the-meter (BTM) solar systems for grid services. However, providing visibility and operational situational awareness of BTM solar systems mainly operated by small-scale solar inverters is challenging due to the requirement of relatively expansive networked observation tools (e.g., micro phasor measurement units (uPMUs)) and consequent cybersecurity threats through networks. This paper presents a secure, cost-effective, uPMUs-like metering method using a blockchain-assisted smart (BAS) inverters for a BTM solar system. The proposed BAS inverter consisting of an internet-of-things device as a node of a local blockchain network enables the secure provision of inverter measurement data for grid services. The BAS inverter sends the encrypted local measurement data with a timestamp to a local blockchain miner. Once the blockchain miner generates a tamper-resistant metering ledger including the measurements, it is used to assess the situational awareness of the BTM solar system. The concept of the proposed metering using the BAS inverters is validated by experimental studies.
Smart and connected communities use technology to better manage their urban energy systems and improve the quality and performance of government services by leveraging big data for data-driven decisions. NREL helps these communities reach their clean energy goals through cutting-edge expertise in planning, data, analytical tools, and technical support.
The average American household spends more than $2,200 a year on energy, and heating, ventilating, and air conditioning (HVAC) costs comprise nearly half of the bill. This is one reason why home builders focus on tightening building envelopes to save energy. Yet, limiting the potential for air exchange can negatively impact indoor air quality (IAQ). When outdoor conditions are most extreme during occupied periods, there may be comfort implications from continuing high levels of ventilation during associated weather events. This is true even with heat recovery. To mitigate risks, the Florida Solar Energy Center developed and tested approaches for “smart” ventilation system controls that enable more reliable design, installation, and operation to achieve desired IAQ while also minimizing energy and comfort impacts.
This paper describes a systematic process of designing resilient electric distribution systems and microgrids using smart meters for surgical load management (SLM) as part of Advanced Metering Infrastructure (AMI). The work focuses on selection approach, integration, and interoperability aspects for AMI in microgrids. SLM is proposed as a granular control methodology for serving selective critical loads across different distribution feeders in the system during extreme events. The surgical load shedding as well as load pick-up provides a robust approach for maximizing critical load served in a resource-constrained electric distribution system or a microgrid. We present the case of a 20 MW islanded microgrid in Cordova, AK, USA, which is the demonstration site for field validation of resilience enhancement technologies for the DOE-funded Grid Modernization project RADIANCE. Cordova microgrid is an islanded distribution grid that provides an environment to prove the approach, and the techniques may also be applicable to other regional distribution systems.
Operation and Maintenance costs of a nuclear power plant account for 60% of overall plant costs due to the nuclear industry?s risk-adverse culture (World Nuclear Association, 2020). The industry relies on highly conservative estimates to avoid risk and brute force reactions to manage the unexpected and keep a plant running safely. This approach has kept plants operating safer than any other power source available over the last six decades (Ritchie, 2020). However, these conservative methods have cost the nuclear industry in market competitiveness. The solution? Transform the conservative approaches to accurate, efficient, and still safe data-driven approaches that leverage advanced technologies available in the digital age of operation. This project endeavored to identify two key aspects to successfully incorporate historical work execution data. First, where in the work management process is that information most pertinent? Next, what variables are key to informing the best strategy for organizing the upcoming work? The Smart Planner uses data collected by dynamic work instructions to provide a basis for suggesting requirements of similar, upcoming work packages. Further, it curbs inefficiencies of the work management process by analyzing the likelihood of discovery work, offering suggestions to build a contingency package. All this taking place as the work planner builds work packages that meet the predetermined scope of work to be performed.
The proliferation of distributed inverter-based resources (IBRs) raises the questions if these IBRs can be used to blackstart microgrids and distribution feeders after major outages. In this paper, we propose and evaluate an autonomous microgrid restoration concept using grid-forming (GFM) IBRs and smart circuit creakers (SCBs). The concept is first explored in simulation platform and then a hardware testbed containing actual GFM inverters is developed to demonstrate these functionalities. A combination of dispatchable virtual oscillator control (dVOC) and droop-based control schemes have been designed for GFM inverter controls in the software simulations and hardware testbed. Subsequently, operation of SCBs using two distinct principles have been demonstrated that can restore or connect portions of the network.
Residences with smart thermostats can use advanced control strategies to manage their cooling/heating demand, but it is difficult to evaluate optimal control strategies for flexible heating, ventilation, and air conditioning (HVAC) systems in a traditional laboratory setting. The HVAC hardware-in-the-loop (HIL) system combines physical HVAC equipment and a physical thermostat with a simulated house to enable realistic operation of the hardware in any climate. This HIL platform allows researchers to evaluate advanced control strategies for homes with different construction or vintage types, as well as different climates and occupancy schedules. To demonstrate the capabilities of the HVAC HIL system, experimental results with a SEER 16, HSPF 9.5, 3 ton single-speed air source heat pump are validated against past field data collected from a heavily instrumented, unoccupied, retrofit house located in Sacramento, California. Three different cooling strategies are recreated in the HVAC HIL platform, including two different pre-cooling schedules that were designed to shift energy use away from the evening peak. The room temperatures, heat pump energy use, and run time show good agreement between the field data and HIL experimental results for three strategies.
In this paper, we examine a basic smart meter network topology in mininet and address the issue of congestion over a commodity network, proposing an adaptive algorithm to cope with varying grid data delivery latencies.
Smart inverters (SI) have huge potential in providing grid services which has not been fully realized yet. One of these grid services, distribution network voltage regulation by SI, can improve the network voltage by regulating the SI reactive and active power output. Voltage regulation by SI is much faster compared to traditional voltage regulating devices, e.g. tap changing transformer, capacitor banks. However, there is gap in available published literature on the characteristics of SIs when the SI is controlled by local controller or external control signal. This paper presents the experimental study to characterize SI reactive power regulation response to two different control methods: autonomous control method and remote dispatch method. It was found that IS reactive power regulation response could be significantly different in terms of delay, and ramp rate for these two methods. Finally, Power-Hardware-in-The-Loop (PHIL) tests were conducted to evaluate the performance of these two methods. The PHIL tests results show that SI response characteristics for autonomous control method and remote dispatch method need to be considered during planning for distribution network voltage regulation using SI.
To facilitate the implementation of distributed energy resource management systems (DERMS), we propose to insert a grid-edge distributed energy resource (DER) chip hosting a DERMS algorithm into the next generation of smart meters. This will create a pathway for the wide adoption of DERMS technology because many utilities plan to invest in advanced metering infrastructure in the near future. This will also bridge the gap between an electrical power utility and DERs behind the meter. The DER chip is designed to follow power direction signals from the DERMS coordinator while balancing its local objectives. We tested the chip using a controller- and power-hardware-in-the-loop evaluation under three scenarios that a DERMS could face in the real world. The DER chip was capable of and effective at directing four heterogeneous DERs to respond to a DERMS coordinator for grid services (e.g., voltage regulation and a virtual power plant).
The U.S. Department of Energy (DOE) Electric Vehicles at Scale Laboratory Consortium (EVs@Scale Lab Consortium) is accelerating research to support the establishment of a secure and scalable national network of charging infrastructure. Critical to this effort is an understanding of the potential grid impacts of EV charging and possible smart charge management (SCM) or vehicle-grid integration (VGI) capabilities that could mitigate these impacts. The EVs@Scale SCM/VGI Pillar is analyzing the impacts of EV charging and developing and demonstrating the capabilities of both SCM and VGI with many different vehicle use cases and grid scenarios. This deep dive discussion of the project encompasses the progress and future plans for the analysis components of the FUSE (Flexible charging to Unify the grid and transportation Sectors for Evs at scale) project.
Our goal is to compute a set of key performance indicators for commercially available smart thermostats using building energy simulation. If successful, the resulting tool will enable EPA ENERGY STAR and other rating/incentive programs to objectively evaluate new thermostat products.
August 3, 2010 Berkeley Lab talk: In the fourth of five Carbon Smackdown matches, Berkeley Lab researchers Delia Milliron of the Materials Sciences Division and Stephen Selkowitz of the Environmental Energy Technologies Division talk about their work on energy-saving smart windows.